Preview only show first 10 pages with watermark. For full document please download

Technical Catalogue

   EMBED


Share

Transcript

eks/ME Technical Catalogue Multi-Scroll Air-Cooled Liquid Chillers Nominal cooling capacity: 47-155 Tons |167-547 kW | 50 Hz eks/ME middle east The harsh climate conditions typical of Middle Eastern areas make energy efficiency and extended operating limits even more crucial factors compared to usual conditions. Euroklimat introduces “eks ME” the air cooled water chillers specifically studied and designed for Middle East. We have focused on energy efficiency and operating limits typical of Middle East climates while developing the eks ME series. The picture refers to the model: eks - BS / ME/AS 160-4-2ME HIGH OUTDOOR AIR TEMPERATURE Specially developed to ensure reliable and durable operation in areas with extreme climate conditions: high outdoor temperature. MAINTENANCE SIMPLICITY The arrangement of the components has been studied in detail in order to allow any operation of maintenance in the simplest and safest way. COMPACT FOOTPRINT The size of the units has been optimized so as to minimize the space occupied, ensuring an easy accessibility to all the components. MULTIPLE CONFIGURATIONS The various configurations and the vast number of available accessories make these units virtually suitable for all applications and every kind of installation. Full load at 120°F Part load at 126°F 2 www.euroklimat.it eks/ME middle east Air cooled water chillers for outdoor installation designed to reach the lowest energy consumption and highest efficiency. The units are equipped with high-efficient SCROLL compressors, “V” condensing shape with increased surface and extremely efficient evaporator with low refrigerant charge and very stable operating performance due to excellent refrigerant distribution. EUROVENT “A” Class Eurovent Certification certifies the performance ratings of airconditioning and refrigeration products according to European and international standards. Every model of eks-ME range is under “A Class” based on Energy Classification. www.euroklimat.it PART-LOAD EFFICIENCY Every refrigerant circuit is equipped with two or three Scroll compressors and during the part-load condition it’s possible to reach the maximum efficiency and more capacity control steps. EC FANS Electronically commutated axial fans give increased performance for reduced power input. Continuous speed control and outstanding efficiency, even in partial load operation. LATEST TECHNOLOGY INSIDE Electronic Expansion Valve   EC fans supplied as standard Microchannel coils 3 eks/ME range eks/ME middle east 055-2-1ME 070-2-1ME Cooling capacity [Tons] Cooling capacity [kW] 47 Tons 59 Tons 20 167 kW 60 080-4-2ME 300 100-4-2ME Cooling capacity [Tons] Cooling capacity [kW] 66 Tons 81 Tons 50 231 kW 90 110-4-2ME 285 kW 200 300 140-4-2ME Cooling capacity [Tons] 95 Tons Cooling capacity [kW] 118 Tons 80 333 kW 140 414 kW 300 500 333 kw - 414 kw 333 kw - 414 kw 180-6-2ME 160-4-2ME Cooling capacity [Tons] 136 Tons 100 4 207 kW 100 Cooling capacity [kW] 155 Tons 479 kW 200 400 547 kW 600 www.euroklimat.it eks/ME operating limits Number of models: 11 - Number of possible configurations: 1000+ www.euroklimat.it eks/ME middle east 5 eks/ME 055-2-1 Refrigerant R410A | GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger 180-6-2 MultiScroll Air-cooled liquid chillers Middle East Solution B - Base I - Integrated Version ST - Standard LN - Low Noise SL - Super Low Noise Equipment AS - Standard equipment DS - Desuperheater HR - Heat Recovery Cooling capacity: 47 - 155 Tons 167 - 547 kW EUROVENT “A” Class Structure Structure specifically designed for outdoor installation. Basement and frame in hot-galvanised shaped sheet steel with a suitable thickness. All parts are polyester-powder painted to assure total weather resistance (RAL 7035 standard colour, others on request). Compressor Hermetic scroll compressor complete with motor over-temperature and over-current devices and protection against excessive gas discharge temperature. Fitted on rubber antivibration mounts and complete with oil charge. EC-Fan Premium-Axial-Fans with bionical shaped blades and high efficient EC (Electronically Commutated) external rotor motors, sealed in protection IP54 and thermal class THCL 155. The motor efficiency class complies with IE4. Air heat exchanger Microchannel Microchannel technology increases the primary to secondary surface area ratio and reduces the tube´s air shadow to provide maximum heat exchange through our condensers. Due to their small hydraulic diameter, microchannel aluminium tubes transfer heat more efficiently than the traditional round copper tubes. Water heat exchanger Plate-type Made of AISI 316 steel complete with water differential pressure switch. Shell covered with closed-cell neoprene anti-condensate material. Shell & tubes All extremely efficient with low refrigerant charge and very stable operating performance due to excellent refrigerant distribution, thermally insulated by vapour-proof closed cell. Electrical board Switchboard made according to standards IEC 204-1/EN60204-1, complete with contactor and protection for compressor and fans. Main isolator and door interlock safety device. Control The microprocessor controls the unit capacity by timing the compressors and checks the operating alarms with the possibility to connect to BMS. Refrigerant circuit Filter dryer, moisture-liquid sight glass, electronic expansion valve, HP and LP pressure sensors and safety valve. Water circuit (Integrated): Automatic charging cock with gauge, safety valve, expansion tank, water pump(s), water tank. MAIN ACCESSORIES Spring vibration isolation Modulating fan speed condensing control (phase-cut) Soft start Compressor suction/discharge intercepting valve Remote control panel Max and min voltage relay Refrigerant gas HP and LP pressure gauges Electromechanical flow switch Pumping group, 1 pump Additional stand-by water pump Automatic water filling valve (closed circuit) For the complete list of accessories please see pages 14-15 6 www.euroklimat.it eks/ME middle east eks/ME middle east Cooling Cooling capacity (1) (EN 14511 VALUE) Cooling capacity (1) (EN 14511 VALUE) Compressors power input (1) (total) EER ESEER EUROVENT classification 055-2-1ME 060-2-1ME 070-2-1ME 080-4-2ME 090-4-2ME 100-4-2ME 110-4-2ME 120-4-2ME 140-4-2ME 160-4-2ME 180-6-2ME [tonsR] 47 53 59 66 74 81 95 106 118 136 155 [kW] 167 186 207 231 260 285 333 373 414 479 547 [kW] 44.4 50.5 57.8 61.9 70.0 79.7 88.8 100.9 115.5 127.2 155.8 - 3.25 3.19 3.09 3.20 3.18 3.12 3.25 3.19 3.09 3.24 3.06 - 4.53 4.59 4.30 4.56 4.63 4.39 4.39 4.31 4.43 4.40 4.36 - A A A A A A A A A A A Desuperheater (option) Heating capacity (2) [kW] 42 48 52 58 64 71 83 92 103 120 137 Exchanger water flow (2) [ft3/min] 4.2 4.9 5.2 5.8 6.5 7.2 8.4 9.3 10.5 12.1 13.8 Exchanger pressure drop (water side) - Plates [kPa] 20 22 24 23 26 22 23 27 22 22 24 Total Heat Recovery (option) Heating capacity (2) [kW] 205 230 257 284 320 354 409 459 513 588 682 Exchanger water flow (2) [ft3/min] 20.7 23.3 26.0 28.7 32.4 35.8 41.4 46.5 52.0 59.5 69.0 Exchanger pressure drop (water side) - Plates [kPa] 40 45 39 47 46 40 44 47 38 41 45 Refrigerant circuit Refrigerant - R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A Number of refrigerant circuits [nr] 1 1 1 2 2 2 2 2 2 2 2 Compressor type - SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL Compressors quantity - 2 2 2 4 4 4 4 4 4 4 6 Fans quantity / type [-] 4/axial (EC) 4/axial (EC) 4/axial (EC) 6/axial (EC) 6/axial (EC) 6/axial (EC) 8/axial (EC) 8/axial (EC) 8/axial (EC) 10/axial (EC) 10/axial (EC) 3 Total air flow [ft /min] 50,618 53,561 56,503 75,927 80,341 80,341 101,235 107,121 113,007 126,544 141,259 Evaporator water flow (1) [ft3/min] 16.9 18.9 20.9 23.4 26.3 28.9 33.7 37.7 41.9 48.5 55.4 Evaporator pressure drop (water side) - Plates [kPa] 51 58 51 56 51 58 47 58 54 59 64 Evaporator pressure drop (water side) - Shell&Tubes [kPa] 48 52 56 43 28 22 40 50 44 35 52 Hydronic kit - 100 kPa useful head (option) Buffer tank capacity Pump type Pump motor nominal power [gal] 71 71 71 71 71 124 124 124 124 124 124 - Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal [hp] 2.9 2.9 2.9 2.9 5.4 5.4 5.4 5.4 7.4 7.4 7.4 Water connections Size [inch] 3” 3” 3” 3” 4” 4” 4” 4” 5” 5” 5” DN80-PN16 DN80 DN80 DN80 DN100 DN100 DN100 DN100 DN125 DN125 DN125 Electrical data Power supply Total installed power compressors Maximum absorbed current compressors Fans power input (total) Fan absorbed current (total) Total installed power Maximum absorbed current (full load) Noise levels (3) Total sound power (ST version) Total sound pressure (ST version) Total sound power (LN version) Total sound pressure (LN version) Total sound power (SL version) Total sound pressure (SL version) - 400V/3ph/50Hz [kW] 64,1 72,2 81,1 92,0 102,0 112,0 128,2 144,4 162,2 180,0 216,6 [A] 113,9 130,8 148,0 160,0 177,0 194,0 227,8 261,6 296,0 330,4 392,4 [kW] 6,4 7,5 8,7 9,7 11,2 11,2 12,9 15,0 17,4 19,3 21,8 [A] 9,8 11,6 13,4 14,8 17,3 17,3 19,7 23,1 26,7 29,5 33,4 [kW] 70,5 79,7 89,8 101,7 113,2 123,2 141,1 159,4 179,6 199,3 238,4 [A] 123,7 142,4 161,4 174,8 194,3 211,3 247,5 284,7 322,7 359,9 425,8 [db(A)] 93 93 94 94 94 95 96 96 97 98 97 [db(A)] 59 60 61 62 60 62 63 61 63 64 65 [db(A)] 89 89 90 90 90 91 92 92 93 94 93 [db(A)] 55 56 57 58 56 58 59 57 59 60 61 [db(A)] 87 87 88 88 88 89 90 90 91 92 91 [db(A)] 53 54 55 56 54 56 58 55 57 58 59 Dimensions and weights Lenght [inch] 116 116 116 169 169 169 217 217 217 268 268 Width [inch] 92 92 92 92 92 92 92 92 92 92 92 Height (ST - LN/SL) [inch] 97 - 99 97 - 99 97 - 99 97 - 99 97 - 99 97 - 99 97 - 99 97 - 99 97 - 99 97 - 99 97 - 99 Weigth BASE unit / BP (brazed plates evaporator) [lbs] 3,461 3,505 3,549 5,401 5,490 5,622 6,658 6,724 6,790 7,937 8,620 Weigth BASE unit / BS (shell & tubes evaporator) [lbs] 3,638 3,682 3,704 4,894 5,688 5,776 6,768 6,856 7,033 8,201 8,885 Weigth INTEGRATED unit / IP (brazed plates evaporator) [lbs] 3,748 3,792 3,836 5,842 5,997 6,085 7,187 7,209 7,253 8,444 9,193 Weigth INTEGRATED unit / IS (shell & tubes evaporator) [lbs] 3,924 3,968 3,990 5,269 6,107 6,173 7,231 7,275 7,452 8,686 9,348 Weigth BASE unit / BP (brazed plates evaporator) / Low Noise [lbs] 3,638 3,682 3,726 5,578 5,842 5,975 7,011 7,077 7,143 8,289 8,973 Weigth BASE unit / BS (shell & tubes evaporator) / Low Noise [lbs] 3,814 3,858 3,880 5,071 6,041 6,129 7,121 7,209 7,385 8,554 9,237 Weigth INTEGRATED unit / IP (brazed plates evaporator) / Low Noise [lbs] 4,211 4,255 4,299 6,415 6,790 6,878 8,069 8,135 8,179 9,326 10,097 Weigth INTEGRATED unit / IS (shell & tubes evaporator) / Low Noise [lbs] 4,387 4,431 4,453 5,798 6,878 6,923 8,047 8,069 8,201 9,502 10,163 Reference conditions: (1) Performance based on EN 14511-3:2013. Condenser air intake temperature = 95°F - Evaporator water temperature IN/OUT = 53.6/44.6°F - Fluid: pure water - Condensing coil: Microchannel (2) Plate heat exchanger water temp. IN/OUT = 104/113°F - Condenser air intake temperature = 95°F - Evaporator water temperature IN/OUT = 53.6/44.6°F - Fluid: pure water - Condensing coil: Microchannel (3) Sound power level in compliance with ISO 3744 - Sound pressure level (average) at 32 feet distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level www.euroklimat.it 7 eks/ME middle east performance tables eks/ME LWT Condenser air temperature [°F] 77 86 95 104 109 115 118 126 055-2-1ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 51 42 48 46 45 50 42 54 40 57 37 63 37 63 27 53 42.8 53 42 49 46 47 50 43 54 42 57 38 64 38 63 28 53 44.6 54 43 51 47 47 51 45 55 43 58 39 64 39 64 29 53 46.4 56 43 53 47 50 51 46 55 44 58 40 64 41 64 30 54 48.2 58 43 54 47 51 51 48 55 46 58 42 64 42 64 31 54 50 59 44 56 47 53 51 49 56 47 59 43 65 43 65 32 54 53.6 63 45 60 48 56 52 52 56 50 59 46 66 46 65 34 54 59 69 46 65 49 62 53 58 57 55 61 50 67 51 66 38 55 060-2-1ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 56 49 53 53 50 57 46 62 44 66 40 72 40 72 30 61 42.8 58 49 55 53 51 57 48 63 46 66 42 73 42 72 31 61 44.6 60 49 56 54 53 58 50 63 47 66 43 73 43 73 32 61 46.4 61 50 58 54 55 58 51 63 49 66 44 74 45 73 33 62 48.2 64 50 60 54 56 59 53 63 50 67 46 74 46 74 34 62 50 66 51 62 54 58 59 54 64 52 67 47 75 48 74 36 62 53.6 70 51 66 55 62 60 58 65 56 68 50 76 51 75 38 62 59 76 52 72 56 68 61 64 66 61 70 55 77 56 76 42 63 070-2-1ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 61 57 58 61 55 66 51 72 49 76 44 84 44 84 33 71 42.8 64 57 60 62 56 66 52 73 50 76 46 85 46 84 34 71 44.6 66 57 62 62 59 66 54 73 52 77 47 85 47 85 35 71 46.4 68 58 64 62 60 67 56 73 54 77 49 86 49 85 37 71 48.2 70 58 66 63 62 68 58 74 55 78 51 86 51 86 38 71 50 72 59 68 63 64 68 60 74 57 78 52 87 52 86 39 71 53.6 77 59 73 64 68 69 63 75 61 79 55 88 56 87 42 72 59 84 61 79 65 75 71 70 76 67 81 61 89 62 88 46 73 080-4-2ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 70 60 67 64 62 70 58 76 56 80 51 88 51 88 37 75 42.8 73 60 69 65 65 70 60 77 58 80 52 89 53 88 39 75 44.6 75 61 71 66 66 72 62 77 59 81 54 89 54 89 40 75 46.4 77 61 73 66 69 71 64 78 61 81 56 90 56 89 42 75 48.2 80 61 75 66 71 72 66 78 63 82 58 90 58 90 43 75 50 82 62 78 67 73 72 68 79 65 82 59 91 60 91 45 75 53.6 88 63 83 67 78 73 73 79 70 83 63 92 64 91 48 76 59 96 64 91 69 85 74 80 80 76 85 70 94 70 93 53 77 090-4-2ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 78 69 74 74 69 80 65 87 62 92 56 101 56 101 41 86 42.8 81 69 76 74 72 80 67 88 64 92 58 102 59 101 43 86 44.6 83 69 78 75 74 81 69 88 66 93 60 102 60 102 45 86 46.4 86 70 81 75 77 81 71 89 68 93 62 103 63 102 46 86 48.2 89 70 84 76 79 82 74 89 70 94 64 103 64 103 48 86 50 91 71 87 76 82 82 76 90 73 94 66 105 67 104 50 86 53.6 97 72 92 77 86 84 81 91 78 95 70 106 71 105 53 87 59 106 74 101 79 95 85 89 92 85 98 77 107 78 106 58 88 100-4-2ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 85 77 80 83 75 91 70 98 67 104 61 115 61 115 45 97 42.8 88 77 83 84 78 91 72 99 70 104 63 116 64 115 47 97 44.6 90 78 85 85 81 91 75 100 72 105 65 116 65 116 48 97 46.4 93 79 88 85 83 92 77 101 74 106 67 117 68 116 50 98 48.2 96 79 91 86 86 93 80 101 76 106 70 117 70 117 52 98 50 99 80 94 86 89 93 82 102 79 107 72 119 72 118 54 98 53.6 106 81 100 87 94 95 88 103 84 108 76 120 77 119 58 99 59 116 83 109 89 103 97 96 104 92 111 84 122 85 121 63 100 77 86 95 104 109 115 118 126 77 86 95 104 109 115 118 126 77 86 95 104 109 115 118 126 77 86 95 104 109 115 118 126 77 86 95 104 109 115 118 126 8 www.euroklimat.it eks/ME middle east performance tables eks/ME LWT Condenser air temperature [°F] 77 86 95 104 109 115 118 126 110-4-2ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 101 85 96 91 90 99 84 108 80 114 73 126 73 126 54 107 42.8 105 85 99 92 93 99 87 109 83 114 75 127 76 126 56 107 44.6 108 86 102 93 95 102 90 109 86 115 78 127 78 127 58 107 46.4 111 87 106 93 99 102 92 110 89 116 80 129 81 127 60 107 48.2 115 87 109 94 102 102 96 110 91 117 83 129 83 129 62 107 50 119 88 113 95 106 102 98 112 95 117 86 130 87 129 65 107 53.6 126 89 120 96 112 104 105 113 101 118 91 132 92 130 69 108 59 138 91 131 98 123 106 115 114 110 121 101 133 102 132 76 109 120-4-2ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 112 98 106 105 99 114 93 124 88 131 81 145 81 145 59 123 42.8 116 98 109 106 103 114 95 125 92 131 83 146 84 145 62 123 44.6 119 99 112 107 106 116 99 126 94 133 86 146 86 146 64 123 46.4 123 100 116 107 110 116 102 127 98 133 89 148 90 147 66 123 48.2 127 100 120 108 113 117 106 127 101 134 92 148 92 148 69 123 50 131 101 124 109 117 117 109 129 104 135 95 150 95 148 71 123 53.6 139 103 132 110 124 120 116 130 111 136 101 152 102 150 76 125 59 152 105 144 113 136 122 127 132 121 139 111 153 112 152 84 126 140-4-2ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 123 113 116 122 109 133 102 144 97 152 89 168 89 168 65 142 42.8 127 113 120 123 113 133 105 145 101 152 91 169 92 168 68 142 44.6 131 115 124 124 118 133 109 146 104 154 95 169 95 169 70 142 46.4 135 116 128 124 120 134 112 147 108 154 98 171 98 170 73 143 48.2 140 116 132 126 124 136 116 147 111 156 101 171 101 171 76 143 50 144 117 136 126 128 136 119 149 115 156 104 173 105 172 78 143 53.6 153 119 145 128 136 139 127 151 122 158 111 176 112 174 83 144 59 168 122 159 131 149 141 140 152 133 162 122 177 123 176 92 146 160-4-2ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 144 124 136 133 127 145 119 157 114 166 104 183 104 183 76 155 42.8 149 124 140 134 132 145 123 158 118 166 107 185 108 183 79 155 44.6 153 125 144 136 136 147 127 159 121 168 111 185 111 185 82 155 46.4 158 126 150 136 141 147 131 160 126 168 114 187 115 185 85 156 48.2 164 126 154 137 145 148 136 161 129 170 118 187 118 187 89 156 50 168 128 160 138 150 148 140 162 134 170 122 189 123 188 92 156 53.6 179 130 170 139 159 152 149 164 143 172 129 191 131 189 98 157 59 196 133 186 143 175 154 163 166 156 176 142 194 144 192 108 159 180-6-2ME °F Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi Cc Pi 41 162 151 154 163 144 177 135 192 128 203 118 225 118 225 86 190 42.8 168 151 159 164 149 177 139 194 133 203 121 227 122 225 90 190 44.6 173 153 163 166 155 178 144 195 137 206 125 227 125 227 93 190 46.4 179 155 169 166 159 179 148 196 142 206 129 229 130 227 96 191 48.2 185 155 174 168 164 182 153 197 146 208 134 229 134 229 100 191 50 190 157 180 168 170 182 158 199 151 209 137 232 139 230 104 191 53.6 203 159 192 170 180 186 168 201 161 211 146 235 148 232 110 193 59 221 162 210 175 197 189 185 204 176 216 161 238 163 236 122 195 77 86 95 104 109 115 118 126 77 86 95 104 109 115 118 126 77 86 95 104 109 115 118 126 77 86 95 104 109 115 118 126 Notes: Cc = Cooling capacity [TonsR] Pi = Power input of the unit (compressors + fans) [kW] LWT = Evaporator Leaving Water Temperature = Part load conditions ETHYLENE GLYCOL Mixture (Meg) - Correction Factor If a Meg is used instead of pure water, it causes a variation in the performance of the unit. For correct data please use the Correction Factor indicated in the following table: Freezing point CcCF 0 (pure water) Meg 20% Meg 30% Meg 40% (1) 32°F 16°F 3.56°F -12.64°F 1 0,980 0,974 0,965 CcCF: Correction factor for cooling capacity (1) For Meg = 40% and for data concerning other kind of anti-freeze solutions please contact our Sales Dept. www.euroklimat.it 9 connected controller Thanks to a Multitasking Operating System and to the adoption of standard protocols, local and remote connectivity the controller used in eks chillers is the most advanced technology available. NEW OPERATING SYSTEM New Multitasking Operating System ensures optimal system resource usage, extended datatypes for user application (32bit floating point numbers) application speed increase and independent protocol engines. CONNECTIVITY The controller has two integrated Ethernet interfaces, three serial interfaces and two USB ports. A great choice of communication protocols is possible (Modbus, Carel, BACNet, LON, Konnex, TCP/IP, HTTP, FTP, DHCP, DNS, NTP, SNMP and many others). 10 CLOUD SERVICE Plug & Play solution for tERA platform connection. All tERA services are available just connecting the Ethernet plug to your home or office network, without the need for an external connection box. www.euroklimat.it application software ekapt The application software “ekapt” developed for eks chillers allows an easy access to the machine configuration and management parameters with the menu system organised by device. There are three password levels to allow three different access modes to the parameters (read only for assistance, edit for servicing, total access for the manufacturer). The main screen gives quick access to the user functions without a password (information on the status of the machine components, On-Off and machine operating mode, set points). PID control There are two types of PID control: - PID control on start-up - PID control during operation [kW] The start-up control must prevent an excess of requested power. Since at start-up the status of the load is not known but only the temperature is, the power must be entered little by little, waiting for the reaction of the system. The control during operation must be quick in order to follow any load variations and maintain the water temperature as close to the set-point value as possible. Compressor’s envelope management The operating limits (hereafter defined as envelope) of the compressors are controlled. This control cannot be disabled in order to prevent the compressor from working outside of the safety limits dictated by the manufacturer. All of the compressors inserted thus contain the envelope data. When the operating condition is outside of the envelope, the alarm delay starts counting: if the operating condition remains outside of the envelope when the delay has elapsed, a specific alarm is activated, which stops the compressor; if, on the other hand, the operating condition returns within the envelope limits, the alarm delay counter is reset. Compressors power distribution “ekapt” application software provides management of the power distributed to the compressors in the best way possible to increase the efficiency of the unit. The behaviour of power distribution changes depending on the configuration, 1 or 2 circuits and the power ratio between compressors. In the event of an alarm for one compressor, the next available compressor will be turned on as a replacement if the request is high enough. For units with two circuits and prevention active in one circuit, the rotation will compensate for the limited circuit by increasing the request on the available circuit. Web commissioning tool Trought internet browser, inserting the IP address of the control card, it will be possible to access the “ekapt” application in order to see and edit service parameters. The application is divided in: Main: in which are shown the main status parameter of the unit; Synoptic: main unit parameters, according to the circuit number and Unit live trend available. Parameters: it is necessary to be logged-in to open the Parameter menu. It is necessary to be, at least, Service user to be able to edit all the parameters. Alarms List: alarms list, with start and end period of the alarm. www.euroklimat.it 11 eks/ME how to select The below legend allows you to easily select the proper configuration of eks chiller. eks - BP / ME/AS 110-3-1 1ps SP Range Configuration BP - Base (brazed plate evaporator) BS - Base (S&T evaporator) IP - Integrated (tank / pump / brazed plate evaporator) IS - Integrated (tank / pump / S&T evaporator) Version ME - Middle east ME/LN - Middle east + Low Noise ME/SL - Middle east + Super Low Noise Solution AS - Standard solution DS - Desuperheater HR - Heat Recovery Model Pump(s) - for IP or IS configuration only 1ps - one pump / standard pressure 2ps - two pumps / standard pressure 1px - one pump / “x” pressure 2px - two pumps / “x” pressure Ex; 1p3: one pump / 3,0 bar pressure SP - used for special configurations / solutions Some of the special “SP” configuration / solutions that Euroklimat offers are: eks with recirculating water pump + user pump eks with recirculating water pump + buffer tank eks with recirculating water pump + buffer tank + additional heat exchanger 12 www.euroklimat.it eks/ME configuration and solutions TYPICAL UNIT CONNECTION TYPICAL UNIT CONNECTION WITH PUMP + BUFFER TANK TYPICAL UNIT CONNECTION WITH PUMP + RESERVE PUMP + BUFFER TANK TYPICAL UNIT CONNECTION WITH PUMP + BUFFER TANK + ADDITIONAL HEAT EXCHANGER TYPICAL UNIT CONNECTION WITH DESUPERHEATER TYPICAL UNIT CONNECTION WITH HEAT RECOVERY LEGEND www.euroklimat.it 13 eks/ME standard equipment and accessories General middle east Anti-vibration spring mounts Anti-vibration seismic spring mounts Standard painting, color RAL 7035 Standard paint, RAL on request Condensing coils protection grills Anti-intrusion grills System of blocks for long-distance transport Condensing section middle east On/Off condensing pressure control (step) Phase-cut modulating fan speed controller - CPC EC Fans (brushless motor) EC Fans (brushless motor) with diffuser kit (standard for LN and SL) Microchannel condensing coil made of aluminum Microchannel condensing coil made of aluminum with ElectroFin® treatment Cu/Al condensing coil Cu/Al condensing coil with ElectroFin® treatment Cu/Cu condensing coil Refrigerant circuit section middle east Compliance with PED Directive (2014/68/EU) Low pressure transducer High pressure transducer Refrigerant leak detector High & Low pressure manometers Compressor suction valve (rotalock) Compressor discharge valve (rotalock) Compressor crankcase oil heater Electronic expansion valve Oil level management with equalizer tube Intelligent oil management “Traxoil®” with additional oil separator * available for some models only. Ask to Euroklimat for more information. Water circuit section middle east Differential pressure switch (exluded ver. with S&T) Electromechanical water flow switch (supplied separately) Electronic water flow switch (supplied separately) Air vent valve (manual) Air vent valve (automatic) Thermal insulation - thickness 0.35 inch Increased thermal insulation - thickness 0:75 inch Water filter 70 U.S. Mesh (supplied separately) Water pipes with trace heating Victaulic® type hydraulic connections * 14 www.euroklimat.it eks/ME standard equipment and accessories Electric cabinet section middle east Forced air cooling system with filter Forced air cooling system with filter - plus version for hot climates Anti-condensation heater with thermostat Device locking doors windproof cabinet Cabinet minimum protection rating IP54 Power supply without neutral Phase monitoring sequence relay Power factor correction capacitors for compressors Min./max. voltage relay Compressors soft-starter Signaling contacts of compressor operation LED cabinet lighting Service socket 230VAC - max. 150 Watt Emergency power electronic expansion valve (Ultracap module) Device for measuring the electric energy consumed (Energy Meter) Control section middle east Integrated Electronic Security module on-board compressor Backlit display Remote control panel Integrated control of the electronic expansion valve Operating hour meter Prevent compressor operating limits (envelope control) Prevent Antifreeze evaporator function Alarm history up to 64 events (data logger function) Second set-point from digital input Remote On/Off digital input Set point compensation by outside temperature ModBus® interface (RS 485) LonWorks® interface (RS 485) BACnet® MS/TP interface BACnet® TCP/IP interface Software updates via USB key Update with transferring files via FTP Update via ctEra cloud service standard equipment www.euroklimat.it optional - not available 15 eks/ME dimensions and operating data eks/ME middle east 055-2-1ME 070-2-1ME Minimum operating space [inch] eks/ME range 055-2-1ME 060-2-1ME 070-2-1ME Dimensions Lenght Width Height (ST - LN/SL) inch 116 inch 92 inch 97 - 99 Weights BASE unit / BP (brazed plates evaporator) BASE unit / BS (shell & tubes evaporator) INTEGRATED unit / IP (brazed plates evaporator) INTEGRATED unit / IS (shell & tubes evaporator) BASE unit / BP (brazed plates evaporator) / Low Noise BASE unit / BS (shell & tubes evaporator) / Low Noise INTEGRATED unit / IP (brazed plates evaporator) / Low Noise INTEGRATED unit / IS (shell & tubes evaporator) / Low Noise lbs lbs lbs lbs lbs lbs lbs lbs 3,461 3,638 3,748 3,924 3,638 3,814 4,211 4,387 3,505 3,682 3,792 3,968 3,682 3,858 4,255 4,431 3,549 3,704 3,836 3,990 3,726 3,880 4,299 4,453 eks/ME middle east 080-4-2ME 100-4-2ME Minimum operating space [inch] eks/ME range 16 080-4-2ME 090-4-2ME 100-4-2ME Dimensions Lenght Width Height (ST - LN/SL) inch 169 inch 92 inch 97 - 99 Weights BASE unit / BP (brazed plates evaporator) BASE unit / BS (shell & tubes evaporator) INTEGRATED unit / IP (brazed plates evaporator) INTEGRATED unit / IS (shell & tubes evaporator) BASE unit / BP (brazed plates evaporator) / Low Noise BASE unit / BS (shell & tubes evaporator) / Low Noise INTEGRATED unit / IP (brazed plates evaporator) / Low Noise INTEGRATED unit / IS (shell & tubes evaporator) / Low Noise lbs lbs lbs lbs lbs lbs lbs lbs 5,401 4,894 5,842 5,269 5,578 5,071 6,415 5,798 5,490 5,688 5,997 6,107 5,842 6,041 6,790 6,878 5,622 5,776 6,085 6,173 5,975 6,129 6,878 6,923 www.euroklimat.it eks/ME dimensions and operating data eks/ME middle east 110-4-2ME 140-4-2ME Minimum operating space [inch] eks/ME range 110-4-2ME 120-4-2ME 140-4-2ME Dimensions Lenght Width Height (ST - LN/SL) inch 217 inch 92 inch 97 - 99 Weights BASE unit / BP (brazed plates evaporator) BASE unit / BS (shell & tubes evaporator) INTEGRATED unit / IP (brazed plates evaporator) INTEGRATED unit / IS (shell & tubes evaporator) BASE unit / BP (brazed plates evaporator) / Low Noise BASE unit / BS (shell & tubes evaporator) / Low Noise INTEGRATED unit / IP (brazed plates evaporator) / Low Noise INTEGRATED unit / IS (shell & tubes evaporator) / Low Noise lbs lbs lbs lbs lbs lbs lbs lbs 6,658 6,768 7,187 7,231 7,011 7,121 8,069 8,047 6,724 6,856 7,209 7,275 7,077 7,209 8,047 8,069 6,790 7,033 7,253 7,452 7,143 7,385 8,047 8,201 eks/ME middle east 160-4-2ME 180-6-2ME Minimum operating space [inch] eks/ME range www.euroklimat.it 160-4-2ME 180-6-2ME Dimensions Lenght Width Height (ST - LN/SL) inch 268 inch 92 inch 97 - 99 Weights BASE unit / BP (brazed plates evaporator) BASE unit / BS (shell & tubes evaporator) INTEGRATED unit / IP (brazed plates evaporator) INTEGRATED unit / IS (shell & tubes evaporator) BASE unit / BP (brazed plates evaporator) / Low Noise BASE unit / BS (shell & tubes evaporator) / Low Noise INTEGRATED unit / IP (brazed plates evaporator) / Low Noise INTEGRATED unit / IS (shell & tubes evaporator) / Low Noise lbs lbs lbs lbs lbs lbs lbs lbs 7,937 8,201 8,444 8,686 8,289 8,554 9,326 9,502 8,620 8,885 9,193 9,348 8,973 9,237 10,097 10,163 17 18 www.euroklimat.it Our plants and quality management Over 50 years of business Since we set up business in 1963, the company’s head offices have always been in Italy, near Milan. Today, our aim is to be a market leader in chillers with natural refrigerant (propane): by doing this, we are helping the industry to become more efficient, preserving natural resources and protecting the environment. Organization in Italy At our Italian plant spread over an area of 6,000 square metres, with a work force of 60 people, Euroklimat designs and produces refrigeration units, heat pumps and precision air conditioners that can be used both in industrial processes and traditional comfort applications. Infinite quality Euroklimat firmly believes that Customer Satisfaction is an indispensable factor for success. A priority objective to achieve this result is the constant improvement of our products, services and the relative production processes. This objective means involving all of the company’s resources with planned, systematic activities for Quality; for this reason, our system complies with the international standard UNI EN ISO 9001:2015. Organization in China Our plant covers a surface of approximately 40,000 square metres, with over 450 people and includes a large test chamber and a sophisticated R&D laboratory, in addition to real production departments, where the performance of the units is measured before being placed on the market. COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV GL = ISO 9001 = Factory Italy • Siziano - Italy www.euroklimat.it Factory China • Huangjiang, Dongguan, Guangdong 19 marcovitidesign The data are indicative and not binding. Euroklimat reserves the right to make changes at any time without notice Factory Italy Via Liguria, 8 27010 Siziano (PV) Italy Factory China Office Dubai T +39 038 2610282 F +39 038 2617782 Euroklimat Industrial Park, Huangjiang, Dongguan, Guangdong, China T +86 0769 8366 0888 ext. 8260 F +86 0769 8362 2528 www.euroklimat.it www.euroklimat.com.cn Office 24, High Bay Complex, Dubai Silicon Oasis, P O Box 28178, DUBAI, United Arab Emirates T + 971 4 326 6278 [email protected] www.euroklimatme.com  “EKS_02-17_rev1_EN” EK Mideast CATALOGO CHILLER “eks_ME” Guangdong Euroklimat Air-Conditioning & Refrigeration Co., Ltd. 99992020 EUROKLIMAT SpA