Technical Data Sheet D6..n

   EMBED


Share

Transcript

Technical data sheet D6..N Wafer type butterfly valves, for shut-off functions • in open and closed cold and hot water systems • for switching heating and cooling machines on and off Overview of types Type DN [mm] kvmax 1) [m3/h] D625N D632N D640N D650N D665N D680N D6100N D6125N D6150N 25 32 40 50 65 80 100 125 150 45 55 70 90 180 300 580 820 1600 1) according Type DN [mm] kvmax 1) [m3/h] D6200N D6250N D6300N D6350N D6400N D6450N D6500N D6600N D6700N 200 250 300 350 400 450 500 600 700 2900 4400 7300 10900 14200 18800 24100 37300 42800 to VDI 2176 Technical data Functional data Media Media temperature Rated pressure ps Flow rate kvs Leakage rate Pipe connectors DN 25 ... DN 200 DN 250 ... DN 350 DN 400 ... DN 700 Suitable connecting flanges Angle of rotation Installation position Maintenance Materials Fitting Disc Stem Seat Stem seal Stem bearing Dimensions / weights Actuation EN-JS1030 (GGG 40), Epoxy powder-coating (RAL 5002) DIN/EN 1.4301 / AISI SS 304 (Stainless steel) DIN/EN 1.4005 / AISI SS 416 (Stainless steel) EPDM EPDM O-ring RPTFE See «Dimensions and weights» on pages 3 and 4 See complete range of water solutions 2) on www.belimo.com Cold and warm water, water with max 50% volume of glycol –20°C ... +120°C 1600 kPa See «Overview of types» A, tight (EN 12266-1) Flange PN 6 / PN 10 / PN 16 (according to ISO 7005-2) Flange PN 10 2) / PN 16 (according to ISO 7005-2) Flange PN 16 (according to ISO 7005-2) According to ISO 7005-2 and EN 1092-2 90° Vertical to horizontal (in relation to the stem) Maintenance-free request T5-D6..N • en • v2.0 • 08.2011 • Subject to changes /4 D6..N Wafer type butterfly valves Safety notes ! • The butterfly valve has been designed for use in stationary heating, ventilation and air conditioning systems and is not allowed to be used outside the specified field of application. especially in aircraft or in any other airborne means of transport. • It may only be installed by suitably trained personnel. Any legal regulations or regulations issued by authorities must be observed during assembly. • The butterfly valve does not contain any parts that can be replaced or repaired by the user. • The butterfly valve may not be disposed of as household refuse. All locally valid regulations and requirements must be observed. • When determining the flow rate characteristic of final controlling elements. the recognised directives must be observed. • In order to avoid water hammers in the piping system, the disc is to be opened and closed slowly. Product features Mode of operation The butterfly valve is opened or closed completely by an open-close rotary actuator. Continuous rotary actuators are controlled by a commercially available controller and move the valve discs into any position desired. The disc made of stainless steel is pressed into the soft-sealing EPDM seat by a rotary movement and ensures leakage rate A (tight). The flow rate losses are slight in open position and the kvs value is high. Manual override Manual throttling or shut-off can be carried out with a lever or a worm gear (see «Accessories»). – With lever (DN 25 ... 150): Adjustable in 10 ratchet steps with position indication (0 = 0° ; 9 = 90° ). – With worm gear (DN 25 ... 700): Steplessly adjustable (self-locking) with position indication. Installation instructions Recommended installation positions Water quality requirements Maintenance Recommendation Butterfly valves should drive once per month a full cycle. The butterfly valves may be mounted from vertical to horizontal. The butterfly valves may not be installed in a hanging position i.e. with the stem pointing downwards. 90° 90° The water quality requirements specified in VDI 2035 must be adhered to. • Butterfly valves, rotary actuators and mechanical accessories are maintenance-free. • Before any kind of service work is carried out on actuator sets of this type. it is essential to isolate the rotary actuator from the power supply (by unplugging the power lead). Any pumps in the part of the piping system concerned must also be switched off and the appropriate isolating fittings closed (allow everything to cool down first if necessary and reduce the pressure in the system to atmospheric). • The system must not be returned to service until the butterfly valve and the rotary actuator have been properly reassembled in accordance with the instructions and the pipework has been refilled in the proper manner. Accessories Mechanical accessories /4 Worm gear Type Weight [kg] ZD6N-S100 ZD6N-S150 ZD6N-S200 ZD6N-S250 ZD6N-S350 ZD6N-S400 ZD6N-S450 ZD6N-S500 ZD6N-S600 ZD6N-S700 4.3 4.6 10.8 10.9 11.9 26.6 27.0 40.9 53.7 94.9 Lever Type ZD6N-H100 ZD6N-H150 T5-D6..N • en • v2.0 • 08.2011 • Subject to changes Weight [kg] 0.4 0.7 for butterfly valves DN 50 ... 100 125 ... 150 200 250 300 ... 350 400 450 500 600 700 www.belimo.com D6..N Wafer type butterfly valves Dimensions [mm] DN 25 ... DN 350 Dimensional drawings 90 ° H2 H3 Xmin H4 1) Ymin S d 90 ° H1 K D DB 45° F B DN [mm] 25 32 40 50 65 80 100 125 150 200 250 300 350 DN [mm] 25 32 40 50 65 80 100 125 150 200 250 300 350 D [mm] 65 65 65 65 65 65 65 90 90 90 125 125 125 Mounting flange 2) F S H3 [mm] [mm] [mm] F05 14 10 F05 14 10 F05 14 10 F05 14 11 F05 14 11 F05 14 11 F05 14 11 F07 17 15 F07 17 15 F07 17 15 F10 22 15 F10 22 15 F10 22 15 SR..A Xmin Ymin [mm] [mm] 220 150 240 150 250 160 270 160 280 170 290 180 300 190 SR..P Xmin Ymin [mm] [mm] 320 150 340 150 350 160 370 160 380 170 390 180 PN 6 H4 [mm] 13 13 13 13 13 13 13 19 19 19 24 24 24 H1 [mm] 48 60 68 72 81 96 106 122 140 172 206 244 267 GR..A Xmin Ymin [mm] [mm] 300 320 340 180 190 210 1) The H2 [mm] 86 100 119 133 147 158 170 194 202 240 268 316 361 B [mm] 32 33 33 43 46 46 52 56 56 60 68 78 78 DB [mm] 30 35 42 52 64 78 103 122 155 202 250 301 333 DGR..A Xmin Ymin [mm] [mm] DR.. Xmin Ymin [mm] [mm] 400 400 500 510 210 220 210 220 K [mm] 75 90 100 110 130 150 170 200 225 280 d [mm] 4 x 11 4 x 14 4 x 14 4 x 14 4 x 14 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 SY1 Xmin Ymin [mm] [mm] 320 150 340 150 350 160 370 160 380 170 390 180 410 190 PN 10 K [mm] 85 100 110 125 145 160 180 210 240 295 350 400 460 SY2 / SY3 Xmin Ymin [mm] [mm] 530 540 580 PN 16 d [mm] 4 x 14 4 x 19 4 x 19 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 8 x 23 12 x 23 12 x 23 16 x 23 210 220 250 K [mm] 85 100 110 125 145 160 180 210 240 295 355 410 470 SY4 / SY5 Xmin Ymin [mm] [mm] 630 680 730 d Weight [mm] [kg] 4 x 14 1.0 4 x 19 1.0 4 x 19 1.4 4 x 19 2.3 4 x 19 2.8 8 x 19 3.3 8 x 19 4.4 8 x 19 6.0 8 x 23 7.3 12 x 23 12.0 12 x 28 18.7 12 x 28 26.8 16 x 28 39.2 SRF (ARF) Xmin Ymin [mm] [mm] 240 150 260 150 280 160 290 160 310 170 310 180 280 310 340 actuator dimensions can be found on the respective actuator data sheet to ISO 5211 2) according www.belimo.com T5-D6..N • en • v2.0 • 08.2011 • Subject to changes /4 D6..N Wafer type butterfly valves Dimensions [mm] DN 400 ... DN 700 Dimensional drawings 90 ° H2 d H3 Xmin H4 1) Ymin S1 ° 90 H1 K DB D S2 45° F B DN [mm] 400 450 500 600 700 D [mm] 175 175 175 210 300 DN [mm] 400 450 500 600 700 Xmin [mm] 1100 F [mm] F14 F14 F14 F16 F25 Mounting flange 2) S1 S2 H3 [mm] [mm] [mm] 22 28.2 20 27 36.2 20 27 36.2 22 36 48.2 22 46 60.2 33 SY4 SY5 Ymin [mm] 1300 H4 [mm] 48 48 48 48 66 H1 [mm] 299 327 349 444 505 Ymin [mm] 1300 Xmin [mm] 1300 1300 SY6 Xmin [mm] Ymin [mm] 1200 1400 Xmin [mm] 1100 H2 [mm] 400 422 480 562 624 B [mm] 102 114 127 154 165 Ymin [mm] 1300 1400 Xmin [mm] Ymin [mm] 1300 1400 1400 1500 SY7 1) The DB [mm] 391 442 493 594 695 K [mm] 525 585 650 770 840 SY8 PN 16 d [mm] 4 x 31 4 x 31 4 x 34 16 x 37 20 x 37 SY9 4 x M33 4 x M33 Weight [kg] 59 73 98 182 281 Xmin [mm] Ymin [mm] SY10 Xmin Ymin [mm] [mm] SY12 Xmin Ymin [mm] [mm] 1700 1800 1500 1800 1800 1800 1800 1800 1800 1900 actuator dimensions can be found on the respective actuator data sheet to ISO 5211 2) according Further documentations /4 • Complete overview «The complete range of water solutions» • Data sheets actuators • Installation instructions for butterfly valves and/or actuators. respectively • Notes for project planning (hydraulic characteristic curves and circuits. installation regulations. commissioning. maintenance etc.) T5-D6..N • en • v2.0 • 08.2011 • Subject to changes www.belimo.com 1 1 4 15 ... 20° ISO 7005-2 EN 1092-2 1 2 1 5 0 >0 70799-00001.B D6..N � 3a 1 2 1 6 1 1 3 4 2 1 3b 1 5 8 3 4 7 6 2 12 M5-D6..N • v1.1 • 08.2010 5 9 8 8 3 12 4 7 10 www.belimo.com 1 6 2 11 15 1 13 5 3 4 10 9 11 6 14 2 16 7 /2 D6..N � � � � 0 0 90° 90° 100% /2 >0 >0 M5-D6..N • v1.1 • 08.2010 0% www.belimo.com 1i 1 4 1000kg 1 1000kg CLOSE 1 10°... 5° 1 5 2 DN 600 DN 700 1 2 1 6 1 3 0 >0 71263-00001.A D6400N ... D6700N + SY.. � 2 10 15 1(2) 17(18) 7 11 14 5 6 12 1 3 A B www.belimo.com M5-D6400N...D6700N+SY.. • v1.0 • 08.2011 13 8 16 19(20) 3(4) 9 DN DN 400 DN 450 DN 500 DN 600 DN 700 A M27 M27 M30 M33 M33 B ≤360 Nm ≤360 Nm ≤510 Nm ≤700 Nm ≤700 Nm /2 D6400N ... D6700N + SY.. 90° /2 � � � � 0 0 90° >0 >0 M5-D6400N...D6700N+SY.. • v1.0 • 08.2011 � � � � 0 0 www.belimo.com >0 1i 1 4 1000kg 1 1000kg 10°... 5° CLOSE 1 OPEN 1 5 2 DN 600 DN 700 1 2 1 6 1 3 0 >0 71324-00001.A D6400N ... D6700N + ZD6N-S.. � 2 10 3 1(2) 17(18) 11 5 6 13 8 16 19(20) 3(4) A B www.belimo.com 7 14 12 1 15 M5-D6400N...D6700N+ZD6N-S.. • v1.0 • 08.2011 9 DN DN 400 DN 450 DN 500 DN 600 DN 700 A M27 M27 M30 M33 M33 B ≤360 Nm ≤360 Nm ≤510 Nm ≤700 Nm ≤700 Nm /2 D6400N ... D6700N + ZD6N-S.. 90° /2 � � � � 0 0 90° >0 >0 M5-D6400N...D6700N+ZD6N-S.. • v1.0 • 08.2011 � � � � 0 0 www.belimo.com >0