Preview only show first 10 pages with watermark. For full document please download

Technical Data Sheet Gl45adb Ve01 115v 60hz ~1

   EMBED


Share

Transcript

TECHNICAL DATA SHEET GL45ADb VE01 115V 60Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3) 4.56 19.09 15.94 8.1 ISO VG 19 ESTER 265 MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω) 1/8 115V 60Hz 92-127 62.501 CSIR 1 PH 11.0 4.59 8.92 APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz) ELECTRICAL COMPONENTS Relay Pick-Up (A) Drop-Out (A) Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Starting capacitor (µF/V)F/V) 2014 131. 5,30 4,50 MRP321LZ 12.6 7.5-14 120.0 / 61.0 150 / 130 Low back pressure R134a -35 to -10 Capillar/Valve Static 43 CYCLE A 81 118 0.69 0.80 1.63 -25.0 55.0 55.0 32.0 115V 60Hz CYCLE B 112 124 0.90 1.05 1.68 -23.3 55.0 32.0 32.0 115V 60Hz T0683 14.8 7.5-14 130.0 / 62.0 DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3 DOC 080327 DESIGNATION Suction/Service Service/Suction Discharge INTERNAL DIAM. (MM) 6,5 6.5 4.9 1/2 TECHNICAL DATA SHEET GL45ADb VE01 115V 60Hz ~1 TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan. 115V 60Hz 32 °C Subcooling at 32 °C MASS FLOW INTENSITY CONSUMPTION COOLING CAPACITY DOC 080327 2/2