Technical Data Sheet Gl70bj Ve01 100v 50/60hz ~1

   EMBED


Share

Transcript

TECHNICAL DATA SHEET GL70BJ VE01 100V 50/60Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3) 6.65 22.0 17.47 106 ISO VG 19 ESTER 450 MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω) 1/5 100V 50Hz 85-110 62.502 RSCR 1 PH 32.7 1.43 5.3 APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz) ELECTRICAL COMPONENTS Relay Nominal voltage (V) Resistanceµ Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Run capacitor (µF/V) Low back pressure R134a -35 to -10 Capillar Oil cooler 43 CYCLE A 110 143 0.77 0.89 2.36 -25.0 55.0 55.0 32.0 100V 50Hz CYCLE B 150 148 1.01 1.17 2.40 -23.3 55.0 32.0 32.0 100V 50Hz PTC 3012 - K115 100 - 115 4,70 4TM774RFBZZ 19.5 5-15 130.0 / 61.0 20 / 180 DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3 DOC 080331 DESIGNATION Suction/Service Service/Suction Discharge INTERNAL DIAM. (MM) 6,5 6.5 4.9 1/2 TECHNICAL DATA SHEET GL70BJ VE01 100V 50/60Hz ~1 TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan. 100V 50Hz 32 °C Subcooling at 32 °C MASS FLOW INTENSITY CONSUMPTION COOLING CAPACITY DOC 080331 2/2