TECHNICAL DATA SHEET GL80EJ VE02 100V 50/60Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3) 8.1 24.29 17.47 11.1 ISO VG 19 ESTER 450 MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω) 1/5 100V 50Hz 85-110 62.035 CSR 1 PH 29.0 1.43 5.81 APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz) ELECTRICAL COMPONENTS Relay Pick-Up (A) Drop-Out (A) Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Starting capacitor (µF/V)F/V) Run capacitor (µF/V) 2014 170. + NTC3 12,20 10,20 MRA38138 15.3 7.5-14 105.0 / 52.0 200 / 125 20 / 180 Low back pressure R134a -35 to 10 Capillar/Valve Oil cooler 43 CYCLE A 123 164 0.74 0.86 2.35 -25.0 55.0 55.0 32.0 100V 50Hz CYCLE B 168 172 0.97 1.13 2.40 -23.3 55.0 32.0 32.0 100V 50Hz T0103 15.8 7.5-14 120.0 / 62.0 DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3 4 DOC 080331 DESIGNATION Suction/Service Service/Suction Discharge Oil Cooler INTERNAL DIAM. (MM) 6,5 6.5 4.9 4.9 1/2 TECHNICAL DATA SHEET GL80EJ VE02 100V 50/60Hz ~1 TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan. 100V 50Hz 32 °C Subcooling at 32 °C MASS FLOW INTENSITY CONSUMPTION COOLING CAPACITY DOC 080331 2/2