Technical Data Sheet Gl80tc Ve01 100v 50/60hz ~1

   EMBED


Share

Transcript

TECHNICAL DATA SHEET GL80TC VE01 100V 50/60Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3) 7.57 25.4 14.9 10.4 ISO VG 22 ESTER 300 MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω) 1/5 100V 50Hz 85-110 62.071 CSIR 1 PH 26.0 1.38 6.12 APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz) ELECTRICAL COMPONENTS Relay Pick-Up (A) Drop-Out (A) Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Starting capacitor (µF/V)F/V) 2014 170. 12,10 10,30 MRT20ALK 15.8 7.5-14 105.0 / 61.0 170 / 130 High/Mid. back pressure R134a -25 to 10 Capillar/Valve Fan cooled 43 CYCLE C 476 297 1.60 1.86 4.58 5.0 55.0 55.0 32.0 100V 50Hz CYCLE D 570 300 1.90 2.20 4.69 7.2 55.0 46.0 35.0 100V 50Hz T0103 15.8 7.5-14 120.0 / 62.0 DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3 DOC 980205 DESIGNATION Suction/Service Service/Suction Discharge INTERNAL DIAM. (MM) 6,5 6.5 4.9 1/2 TECHNICAL DATA SHEET GL80TC VE01 100V 50/60Hz ~1 TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan. 100V 50Hz 35 °C Subcooling 9 K MASS FLOW INTENSITY CONSUMPTION COOLING CAPACITY DOC 980205 2/2