Technical Data Sheet Gl90af Ve01 200-220/220

   EMBED


Share

Transcript

TECHNICAL DATA SHEET GL90AF VE01 200-220/220-230V 50/60Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3) 9.08 24.29 19.62 10.8 ISO VG 19 ESTER 445 MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω) 1/4 220V 50Hz 170-242 62.512 RSIR 1 PH 18.0 5.3 8.51 APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz) ELECTRICAL COMPONENTS Relay Nominal voltage (V) Resistanceµ Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Low back pressure R134a -35 to -10 Capillar Static 43 CYCLE A 140 193 0.72 0.84 1.86 -25.0 55.0 55.0 32.0 220V 50Hz CYCLE B 191 202 0.94 1.09 1.87 -23.3 55.0 32.0 32.0 220V 50Hz PTC 3003 - K100 200 - 240 14,00 4TM757NFBYY 10.4 5-15 120.0 / 61.0 DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3 DOC 080327 DESIGNATION Suction/Service Service/Suction Discharge INTERNAL DIAM. (MM) 6,5 6.5 4.9 1/2 TECHNICAL DATA SHEET GL90AF VE01 200-220/220-230V 50/60Hz ~1 TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan. 220V 50Hz 32 °C Subcooling at 32 °C MASS FLOW INTENSITY CONSUMPTION COOLING CAPACITY DOC 080327 2/2