Preview only show first 10 pages with watermark. For full document please download

Technical Data Sheet Gl90rg Ve01 200-220/220

   EMBED


Share

Transcript

TECHNICAL DATA SHEET GL90RG VE01 200-220/220-230V 50/60Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3) 8.85 25.4 17.47 10.9 ISO VG 22 ESTER 300 MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω) 1/4 200V 50Hz 170-242 62.089 CSR 1 PH 12.5 5.91 18.81 APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz) ELECTRICAL COMPONENTS Relay Pick-Up (A) Drop-Out (A) Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Starting capacitor (µF/V)F/V) Run capacitor (µF/V) 2014 145. + NTC15 7,00 5,90 MRP56AMK 9.4 7.5-14 105.0 / 61.0 47- 56 / 330 4 / 400 High/Mid. back pressure R134a -25 to 10 Capillar/Valve Fan cooled 43 CYCLE C 568 327 1.73 2.02 1.93 5.0 55.0 55.0 32.0 200V 50Hz CYCLE D 680 340 2.00 2.32 2.00 7.2 55.0 46.0 35.0 200V 50Hz T0057 8.5 7.5-14 105.0 / 61.0 DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3 DOC 080331 DESIGNATION Suction/Service Service/Suction Discharge INTERNAL DIAM. (MM) 6,5 6.5 4.9 1/2 TECHNICAL DATA SHEET GL90RG VE01 200-220/220-230V 50/60Hz ~1 TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan. 200V 50Hz 35 °C Subcooling 9 K MASS FLOW INTENSITY CONSUMPTION COOLING CAPACITY DOC 080331 2/2