Preview only show first 10 pages with watermark. For full document please download

Technical Data Sheet Hly80aaa Ve01 220

   EMBED


Share

Transcript

TECHNICAL DATA SHEET HLY80AAa VE01 220-240V 50Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3) 8.1 24.29 17.48 9.1 ISO VG 10 MINERAL 210 MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω) 1/7 220V 50Hz 187-264 63.503 RSIR 1 PH 8.6 22.02 22.53 APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz) ELECTRICAL COMPONENTS Relay Nominal voltage (V) Resistanceµ Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Low back pressure R600a -35 to -10 Capillar Static 43 CYCLE A 85 89 0.95 1.11 0.60 -25.0 55.0 55.0 32.0 220V 50Hz PTC 3003 - K100 200 - 240 14,00 MSP318LZ T0462 AE37FJ 5.9 7.5-14 120.0 / 61.0 5.9 7.5-14 115.0 / 62.0 6.2 7.5-14 110.0 / 62.0 CYCLE B 113 93 1.21 1.41 0.61 -23.3 55.0 32.0 32.0 220V 50Hz 4TM189NFBY Y 5.5 5-15 120.0 / 61.0 DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3 DOC 080327 DESIGNATION Suction/Service Service/Suction Discharge INTERNAL DIAM. (MM) 6,5 6.5 4.9 1/2 TECHNICAL DATA SHEET HLY80AAa VE01 220-240V 50Hz ~1 TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan. 220V 50Hz 32 °C Subcooling at 32 °C MASS FLOW INTENSITY CONSUMPTION COOLING CAPACITY DOC 080327 2/2