Preview only show first 10 pages with watermark. For full document please download

Technical Data Sheet Hly90aaa Ve01 220

   EMBED


Share

Transcript

TECHNICAL DATA SHEET HLY90AAa VE01 220-240V 50Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3) 9.08 24.29 19.6 9.5 ISO VG 10 MINERAL 345 MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω) 1/6 220V 50Hz 187-264 63.508 RSIR 1 PH 9.3 17.64 21.62 APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz) ELECTRICAL COMPONENTS Relay Nominal voltage (V) Resistanceµ Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Low back pressure R600a -35 to -10 Capillar Static 43 CYCLE A 94 98 0.95 1.11 0.69 -25.0 55.0 55.0 32.0 220V 50Hz PTC 3003 - K100 200 - 240 14,00 MSP331LZ T0366 AE37FJ 6.2 7,5-14 120.0 / 61.0 5.9 7.5-14 115.0 / 62.0 6.8 7,5-14 120.0 / 62.0 CYCLE B 125 103 1.21 1.41 0.71 -23.3 55.0 32.0 32.0 220V 50Hz 4TM222NFBY Y 7.0 5-15 120.0 / 61.0 DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3 DOC 080327 DESIGNATION Suction/Service Service/Suction Discharge INTERNAL DIAM. (MM) 6,5 6.5 4.9 1/2 TECHNICAL DATA SHEET HLY90AAa VE01 220-240V 50Hz ~1 TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan. 220V 50Hz 32 °C Subcooling at 32 °C MASS FLOW INTENSITY CONSUMPTION COOLING CAPACITY DOC 080327 2/2