Technical Data Sheet Ml60tg Ve01 200

   EMBED


Share

Transcript

TECHNICAL DATA SHEET ML60TG VE01 200-220/230V 50/60Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3) 5.67 21.99 14.9 10 ISO VG 46 ESTER 300 MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω) 1/4 200V 50Hz 170-242 62.079 CSIR 1 PH 12.0 6.5 31.46 APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz) ELECTRICAL COMPONENTS Relay Pick-Up (A) Drop-Out (A) Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Starting capacitor (µF/V)F/V) 2014 138. 6,10 5,20 MRT26AMK 11.1 7.5-14 105.0 / 61.0 47- 56 / 330 High/Mid. back pressure R404A -25 to 10 Capillar/Valve Fan cooled 43 CYCLE C 556 424 1.31 1.52 2.67 5.0 55.0 55.0 32.0 200V 50Hz CYCLE D 700 440 1.59 1.85 2.74 7.2 55.0 46.0 35.0 200V 50Hz T0181 11.1 7.5-14 105.0 / 61.0 DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3 DOC 980902 DESIGNATION Suction/Service Service/Suction Discharge INTERNAL DIAM. (MM) 6,5 6.5 4.9 1/2 TECHNICAL DATA SHEET ML60TG VE01 200-220/230V 50/60Hz ~1 TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan. 200V 50Hz 35 °C Subcooling 9 K MASS FLOW INTENSITY CONSUMPTION COOLING CAPACITY DOC 980902 2/2