Preview only show first 10 pages with watermark. For full document please download

Technical Manu Al Technical Manual *sxc 16 Seer

   EMBED


Share

Transcript

TECHNICAL MANU AL MANUAL *SXC 16 SEER Condensing Units • Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • See models on page 3. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2009-2014 Goodman Manufacturing Company, L.P. RT6114004r10 March 2014 PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. D S X C BRAND: D: Deluxe Goodman® Brand A: Amana® Brand 16 COMMUNICATION FEATURE: C: 4-wire Communication Ready A MINOR REVISION: A: Initial Release NOMINAL CAPACITY: 024: 2 Tons 036: 3 Tons 048: 4 Tons 060: 5 Tons ELECTRICAL: 1: 208-230V/1ph/60Hz 3: 208-230v/3ph/60Hz 4: 460v/3ph/60Hz HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. 2 A MAJOR REVISION: A: Initial Release PRODUCT TYPE: C: Condenser R-22 H: Heat Pump R-22 X: Condenser R-410A Z: Heat Pump R-410A WARNING 1 SEER: SEER Rating PRODUCT FAMILY: S: Split System WARNING 024 ONLY individuals meeting (at a minimum) the requirements of an "entry level technician" as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) may use this information. Attempting to install or repair this unit without such background may result in product damage, personal injury or death. WARNING PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. ASXC160241A* ASXC160361A* ASXC160481A* ASXC160601A* DSXC160241A* DSXC160361A* DSXC160481A* DSXC160601A* ASXC160241B* ASXC160361B* ASXC160481B* ASXC160601B* DSXC160481B* DSXC160601B* * Indicates minor revision & is not used for order entry or inventory management WARNING The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. WARNING 3 PRODUCT DESIGN Models covered by this manual come with a new 4-wire communicating PCB. When paired with a compatible communicating indoor unit and a communicating thermostat, these models can support 4-wire communication protocol and provide more troubleshooting information. These models are also backward compatible with the legacy thermostat wiring. *SXC16 models are available in 2, 3, 4 and 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt single phase applications. The condenser air is pulled through the condenser coil by a direct drive propeller fan. This condenser air is then discharged out of the top of the cabinet. These units are designed for free air discharge, so no additional resistance like duct work shall be attached. The suction and liquid line connections on present models are of the sweat type for field piping with refrigerant type copper. Front seating valves are factory installed to accept the field run copper. The total refrigerant charge for a normal installation is factory installed in the condensing unit. *SXC units are charged for the matching evaporator coil and a 15 foot refrigerant line set. Operating pressures and amp draws may differ from standard reciprocating and/or scroll compressors. This information may be found in the "Cooling Performance Data" section. This unit is for outdoor installation only. Refer to figure for minimum clearances from the sides of the unit to full walls and other objects. NOTE: This unit cannot be completely enclosed. At least one side must be unrestricted. These clearances will help avoid air recirculation. If installing two or more units at the same location, allow at least 24 inches between units. If only one side is restricted (for example, against the outside wall of a house), the unit may be placed as close as 8" to that one wall. DO NOT locate the unit: * Directly under a vent termination for a gas appliance. * Within 3 feet of a clothes drier vent * Where the refreezing of defrost water would create a hazard * Where water may rise into the unit. Systems should be properly sized by heat gain and loss calculations made according to methods of the Air Conditioning Contractors Association (ACCA) or equivalent. It is the contractors responsibility to ensure the system has adequate capacity to heat or cool the conditioned space. *SXC16 models use the Copeland Scroll "Ultratech" Series compressors which are specifically designed for R-410A refrigerant. There are a number of design characteristics which are different from the traditional reciprocating and/or scroll compressors. "Ultratech" Series scroll compressors with Copeland® ComfortAlert diagnostics will not have a discharge thermostat, some of the early model scroll compressors required discharge thermostats. NOT RECOMMENDED B "Ultratech" Series scroll compressors use "POE" or polyolester oil which is NOT compatible with mineral oil based lubricants like 3GS. "POE" oil must be used if additional oil is required. WARNING To avoid possible injury, explosion or death, practice safe handling of refrigerants. 4 B A OK! AA C A OK! B AA OK! C AA AA AA Due to their design Scroll compressors are inherently more tolerant of small quantities of liquid refrigerant. NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued floodback or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure. B OK! OK! OK! AA AA C C Model Type A B C AA Residential 10" 10" 18" 20" Light Commercial 12' 12" 18" 24" CONDENSING UNIT SPECIFICATIONS A/DSXC160[24-60]1A* Dimensions M odel Dim ens ions - W x D x H *SXC 16 0 2 41 A* 29 x 29 x 32¼ *SXC 16 0 3 61 A* 29 x 29 x 38¼ *SXC 16 0 4 81 A* 35 ½ x 3 5 ½ x 3 8 ¼ *SXC 16 0 6 01 A* 35 ½ x 3 5 ½ x 3 8 ¼ A/DSXC160241A* - A/DSXC160601A* *SXC160241A* *SXC16036A* *SXC160481A* *SXC160601A* 24,000 36,000 48,000 60,000 R.L. Amps 10.3 16.7 21.2 25.6 L.R. Amps 52.0 82.0 96.0 118.0 Open 22 PSIG 22 PSIG 22 PSIG 22 PSIG Close 50 PSIG 50 PSIG 50 PSIG 50 PSIG Open 610 PSIG 610 PSIG 610 PSIG 610 PSIG Close 420 PSIG 420 PSIG 420 PSIG 420 PSIG Horsepower 1/12 1/6 1/6 1/6 F.L. Amps 0.6 1.0 1.0 1.0 Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8" Suc tion Line, Inches O.D.* 3/4" 7/8" 1-1/8" 1-1/8" 137.0 157.0 202.0 197.0 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 13.5 21.9 27.5 33.0 20 35 45 50 Power Supply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 Approx imate Shipping W eight 282 282 296 296 Cooling Capac ity, BTUH Compressor Low Pressure Switch High Pressure Switch Condenser Fan Motor Refrigerant Charge Power Supply Minimum Circuit Ampacity (1) Max imum Overc urrent Device (2) Electrical Conduit Size * Up to 24' in equivalent line length Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes. (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. (1) NOTES: • Always check the S & R plate for electrical data on the unit being installed. • Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units). • Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit). • Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. 5 CONDENSING UNIT SPECIFICATIONS Dimensions Model ASXC160[24-36]1B* Dimensions - W x D x H ASXC160241B* 29 x 29 x 30¼ ASXC160361B* 29 x 29 x 30¼ AS XC160241BB A S XC160241B C A SXC160361B B AS XC160361BC 24,000 24,000 36,000 36,000 R.L. A mps 10.3 11.7 16.7 15.3 L.R. A mps 52.0 58.3 82.0 83.0 Open 22 P S IG 22 P SIG 22 PS IG 22 P S IG Clos e 50 P S IG 50 P SIG 50 PS IG 50 P S IG Open 610 PS IG 610 P S IG 610 P SIG 610 PS IG Clos e 420 PS IG 420 P S IG 420 P SIG 420 PS IG Hors epower 1/6 1/6 1/6 1/6 F.L. Amps 1.1 1.1 0.9 0.9 Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8" S uction Line, Inches O.D.* 3/4" 3/4" 7/8" 7/8" 100.0 88.0 110.0 96.0 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 14.0 15.7 21.8 20.0 20 20 35 35 Power S upply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 A pprox imate Shipping W eight 198 198 202 202 Cooling Capacity, B TUH Compressor Low Pres sure S witch High P ress ure Switc h Condens er Fan Motor Refrigerant Charge P ower Supply Minimum Circ uit A mpac ity (1) Maximum Overcurrent Device (2) E lectrical Conduit S iz e * Up to 24' in equivalent line length Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes. (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. (1) NOTES: • Always check the S & R plate for electrical data on the unit being installed. • Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units). • Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit). • Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. 6 CONDENSING UNIT SPECIFICATIONS Dimensions Model ASXC160[48-60]1B* Dimensions - W x D x H ASXC160481B* 35½ x 35½ x 36¼ ASXC160601B* 35½ x 35½ x 38¼ ASXC160481B* ASXC160481BC AS XC160601B* A SXC160601BC 48,000 48,000 60,000 60,000 R.L. Amps 21.2 21.2 25.6 28.8 L.R. Amps 96.0 104.0 118.0 152.9 Open 55 PSIG 55 PSIG 22 PSIG 22 PS IG Clos e 95 PSIG 95 PSIG 50 PSIG 50 PS IG Open 610 PSIG 610 PSIG 610 P SIG 610 PSIG Clos e 420 PSIG 420 PSIG 420 P SIG 420 PSIG Horsepower 1/6 1/6 1/6 1/6 F.L. A mps 1.0 1.2 1.0 1.2 3/8" 3/8" 3/8" 3/8" Suc tion Line, Inc hes O.D.* 1 1/8" 1 1/8" 1 1/8" 1 1/8" Refrigerant Charge 135.0 135.0 200.0 200.0 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 27.5 27.7 33.0 37.2 45 45 50 60 Power Supply (Inc hes) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 Approx imate Shipping W eight 241 241 301 301 Cooling Capacity , BTUH Com pres sor Low P ressure Switch High Pressure Switch Condenser Fan M otor Liquid Line, Inc hes O.D.* Power Supply M inimum Circ uit Ampac ity (1) M ax imum Overc urrent Devic e (2) Electric al Conduit Size * Up to 24' in equivalent line length Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes. (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. (1) NOTES: • Always check the S & R plate for electrical data on the unit being installed. • Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units). • Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit). • Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. 7 CONDENSING UNIT SPECIFICATIONS DSXC160[24-36]1A* Dimensions Model Dimensions - W x D x H DSXC160241A* 29 x 29 x 30¼ DSXC160361A* 29 x 29 x 30¼ DSXC160241AB DSXC160241AC DSXC160361AB DSXC160361AC 24,000 24,000 36,000 36,000 R.L. Amps 10.3 11.7 16.7 15.3 L.R. Amps 52.0 58.3 82.0 83.0 Open 22 PSIG 22 PSIG 22 PSIG 22 PSIG Close 50 PSIG 50 PSIG 50 PSIG 50 PSIG Open 610 PSIG 610 PSIG 610 PSIG 610 PSIG Close 420 PSIG 420 PSIG 420 PSIG 420 PSIG Horsepower 1/6 1/6 1/6 1/6 F.L. Amps 1.1 1.1 0.9 0.9 Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8" Suction Line, Inches O.D.* 3/4" 3/4" 7/8" 7/8" 100.0 88.0 110.0 96.0 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 14.0 15.7 21.8 20.0 20 20 35 35 Power Supply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 Approximate Shipping Weight 198 198 202 202 Cooling Capacity, BTUH Compressor Low Pressure Switch High Pressure Switch Condenser Fan Motor Refrigerant Charge Power Supply Minimum Circuit Ampacity (1) Maximum Overcurrent Device(2) Electrical Conduit Size * Up to 24' in equivalent line length Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes. (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. (1) NOTES: • Always check the S & R plate for electrical data on the unit being installed. • Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units). • Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit). • Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. 8 CONDENSING UNIT SPECIFICATIONS Dimensions Model DSXC160[48-60]1B* Dimensions - W x D x H DSXC160481B* 35½ x 35½ x 36¼ DSXC160601B* 35½ x 35½ x 38¼ DSXC160481B* DSXC160481BC DSXC160601B* DSXC160601BC 48,000 48,000 60,000 60,000 R.L. Amps 21.2 21.2 25.6 28.8 L.R. Amps 96.0 104.0 118.0 152.9 Open 55 PSIG 55 PSIG 22 PSIG 22 PSIG Close 95 PSIG 95 PSIG 50 PSIG 50 PSIG Open 610 PSIG 610 PSIG 610 PSIG 610 PSIG Close 420 PSIG 420 PSIG 420 PSIG 420 PSIG Horsepower 1/6 1/6 1/6 1/6 F.L. Amps 1.0 1.2 1.0 1.2 3/8" 3/8" 3/8" 3/8" Suction Line, Inches O.D.* 1 1/8" 1 1/8" 1 1/8" 1 1/8" Refrigerant Charge 135.0 135.0 200.0 200.0 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 27.5 27.7 33.0 37.7 45 45 50 60 Power Supply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 Approximate Shipping Weight 241 241 301 301 Cooling Capacity, BTUH Compressor Low Pressure Switch High Pressure Switch Condenser Fan Motor Liquid Line, Inches O.D.* Power Supply Minimum Circuit Ampacity (1) Maximum Overcurrent Device(2) Electrical Conduit Size * Up to 24' in equivalent line length Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes. (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. (1) NOTES: • Always check the S & R plate for electrical data on the unit being installed. • Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units). • Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit). • Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL. NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only. Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. 9 10 675 600 525 675 600 525 Airflow 59 16.1 0.69 19 1.08 4.4 223 119 17.5 0.71 19 1.09 4.4 226 120 18.0 0.75 18 1.10 4.5 228 122 16.4 0.78 22 1.08 4.4 223 119 17.8 0.81 22 1.09 4.4 226 120 18.3 0.85 21 1.10 4.5 228 122 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 16.9 0.70 21 1.10 4.5 240 123 18.3 0.73 20 1.11 4.5 243 124 18.8 0.76 20 1.12 4.6 245 125 63 16.7 0.58 17 1.10 4.5 240 123 18.1 0.60 17 1.11 4.5 243 124 18.7 0.63 16 1.12 4.6 245 125 18.3 0.53 17 1.14 4.6 244 134 19.8 0.55 17 1.15 4.7 246 136 20.4 0.58 16 1.16 4.7 248 137 67 18.3 0.40 13 1.14 4.6 244 134 19.8 0.41 13 1.15 4.7 246 136 20.4 0.43 12 1.16 4.7 248 137 19.6 0.34 12 1.18 4.8 249 143 21.3 0.35 12 1.19 4.8 251 144 21.9 0.37 11 1.20 4.9 254 146 71 16.0 0.81 23 1.17 4.7 252 123 17.4 0.84 22 1.18 4.8 255 124 17.9 0.88 21 1.19 4.8 258 125 59 15.8 0.71 20 1.17 4.7 252 123 17.1 0.74 19 1.18 4.8 255 124 17.6 0.78 19 1.19 4.8 258 125 16.5 0.73 21 1.19 4.8 271 127 17.9 0.75 21 1.20 4.9 274 128 18.4 0.79 20 1.21 4.9 277 129 63 16.3 0.60 17 1.19 4.8 271 127 17.7 0.62 17 1.20 4.9 274 128 18.2 0.65 16 1.21 4.9 277 129 75 17.9 0.55 17 1.23 5.0 275 138 19.3 0.57 17 1.24 5.0 278 140 19.9 0.60 16 1.25 5.1 281 141 67 17.9 0.41 13 1.23 5.0 275 138 19.4 0.43 13 1.24 5.0 278 140 20.0 0.45 12 1.25 5.1 281 141 19.2 0.35 12 1.27 5.2 281 147 20.8 0.37 12 1.29 5.2 284 149 21.4 0.38 11 1.30 5.3 287 150 71 15.6 0.83 23 1.24 5.1 287 127 16.9 0.86 22 1.25 5.2 290 128 17.5 0.90 22 1.26 5.2 293 129 59 15.4 0.73 20 1.24 5.1 287 127 16.7 0.76 19 1.25 5.2 290 128 17.2 0.80 19 1.26 5.2 293 129 16.1 0.74 21 1.27 5.3 309 131 17.4 0.77 21 1.28 5.3 312 132 18.0 0.81 20 1.29 5.3 315 133 17.4 0.56 17 1.31 5.4 313 143 18.9 0.58 17 1.33 5.5 316 144 19.4 0.61 16 1.34 5.5 319 146 18.7 0.36 12 1.36 5.6 320 152 20.3 0.38 12 1.37 5.7 323 154 20.9 0.39 11 1.38 5.7 326 155 15.3 0.86 23 1.31 5.5 327 130 16.5 0.89 23 1.32 5.5 330 132 17.0 0.93 22 1.33 5.6 334 133 15.7 0.77 21 1.34 5.6 352 134 17.0 0.80 21 1.35 5.7 355 136 17.5 0.84 20 1.37 5.7 359 137 17.0 0.58 17 1.39 5.8 357 147 18.4 0.60 17 1.40 5.8 360 148 19.0 0.63 16 1.41 5.9 364 150 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 15.9 17.5 15.0 15.6 17.0 0.61 0.42 0.76 0.63 0.44 17 13 20 17 13 1.27 1.31 1.31 1.34 1.39 5.3 5.4 5.5 5.6 5.8 309 313 327 352 357 131 143 130 134 147 17.3 18.9 16.3 16.8 18.5 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 1.28 1.33 1.32 1.35 1.40 5.3 5.5 5.5 5.7 5.8 312 316 330 355 360 132 144 132 136 148 17.8 19.5 16.7 17.4 19.0 0.66 0.46 0.82 0.69 0.48 16 12 19 16 12 1.29 1.34 1.33 1.37 1.41 5.3 5.5 5.6 5.7 5.9 315 319 334 359 364 133 146 133 137 150 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 18.2 0.37 12 1.44 6.0 364 156 19.8 0.39 12 1.45 6.1 368 158 20.4 0.41 11 1.46 6.1 372 159 71 14.5 0.89 23 1.37 5.8 368 133 15.7 0.92 22 1.38 5.9 372 134 16.2 0.97 21 1.39 5.9 375 135 59 14.3 0.78 20 1.37 5.8 368 133 15.4 0.81 19 1.38 5.9 372 134 15.9 0.85 18 1.39 5.9 375 135 14.9 0.80 21 1.40 6.0 396 137 16.2 0.83 20 1.41 6.0 400 138 16.7 0.87 20 1.43 6.1 404 140 63 14.8 0.65 17 1.40 6.0 396 137 16.0 0.68 17 1.41 6.0 400 138 16.5 0.71 16 1.43 6.1 404 140 16.2 0.60 17 1.45 6.2 401 150 17.5 0.63 17 1.46 6.2 405 151 18.0 0.66 16 1.48 6.3 409 153 67 16.2 0.45 13 1.45 6.2 401 150 17.5 0.47 13 1.46 6.2 405 151 18.1 0.49 12 1.48 6.3 409 153 105 13.4 0.90 21 1.42 6.2 412 136 14.5 0.93 21 1.43 6.2 416 137 15.0 0.98 20 1.44 6.3 420 139 59 13.2 0.79 18 1.42 6.2 412 136 14.3 0.82 18 1.43 6.2 416 137 14.7 0.86 17 1.44 6.3 420 139 13.8 0.80 19 1.45 6.3 443 140 15.0 0.83 19 1.47 6.4 447 142 15.4 0.87 18 1.48 6.4 452 143 63 13.7 0.66 16 1.45 6.3 443 140 14.8 0.68 16 1.47 6.4 447 142 15.3 0.72 15 1.48 6.4 452 143 15.0 0.61 16 1.50 6.5 449 153 16.2 0.63 16 1.52 6.6 454 155 16.7 0.66 15 1.53 6.6 458 156 67 15.0 0.46 12 1.50 6.5 449 153 16.2 0.47 12 1.52 6.6 454 155 16.7 0.50 11 1.53 6.6 458 156 16.1 0.39 11 1.56 6.8 459 163 17.4 0.41 11 1.57 6.8 464 165 17.9 0.43 10 1.58 6.9 468 166 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 17.3 0.39 12 1.50 6.4 410 159 18.8 0.40 12 1.51 6.4 414 161 19.3 0.42 11 1.53 6.5 418 162 71 - 115 COOLING OPERATION MODEL: *SXC160241A* / CA*F3636C6** + TXV / MBVC1200**-1**, Design Subcooling @ AHRI 95°F Conditions, 5°F @ Serv. Vlv. EXPANDED PERFORMANCE DATA PERFORMANCE DATA ASXC160241A*-LOW STAGE 675 600 525 675 600 525 Airflow 63 17.1 0.81 24 1.10 4.5 240 123 18.5 0.84 24 1.11 4.5 243 124 19.0 0.88 23 1.12 4.6 245 125 17.3 0.87 26 1.10 4.5 240 123 18.8 0.90 26 1.11 4.5 243 124 19.3 0.94 25 1.12 4.6 245 125 59 16.7 0.86 25 1.08 4.4 223 119 18.1 0.89 25 1.09 4.4 226 120 18.6 0.93 24 1.10 4.5 228 122 MBh 17.0 S/T 0.90 Delta T 27 KW 1.08 AMPS 4.4 223 HI PR LO PR 119 MBh 18.4 S/T 0.93 Delta T 26 KW 1.09 AMPS 4.4 HI PR 226 LO PR 120 MBh 19.0 S/T 0.98 Delta T 25.27 KW 1.10 AMPS 4.5 HI PR 228 LO PR 122 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 18.1 0.78 25 1.14 4.6 244 134 19.6 0.81 24 1.15 4.7 246 136 20.2 0.85 23 1.16 4.7 248 137 67 18.2 0.66 21 1.14 4.6 244 134 19.7 0.68 21 1.15 4.7 246 136 20.3 0.71 20 1.16 4.7 248 137 19.3 0.64 22 1.18 4.8 249 143 21.0 0.66 21 1.19 4.8 251 144 21.6 0.69 20 1.20 4.9 254 146 71 19.5 0.49 17 1.18 4.8 249 143 21.1 0.51 16 1.19 4.8 251 144 21.7 0.53 16 1.20 4.9 254 146 16.6 0.93 27 1.17 4.7 252 123 18.0 0.97 27 1.18 4.8 255 124 18.5 1.00 25 1.19 4.8 258 125 59 16.3 0.89 25 1.17 4.7 252 123 17.7 0.92 25 1.18 4.8 255 124 18.2 0.97 24 1.19 4.8 258 125 16.9 0.90 27 1.19 4.8 271 127 18.3 0.93 26 1.20 4.9 274 128 18.9 0.98 25 1.21 4.9 277 129 63 16.7 0.83 24 1.19 4.8 271 127 18.1 0.87 24 1.20 4.9 274 128 18.6 0.91 23 1.21 4.9 277 129 75 17.7 0.81 25 1.23 5.0 275 138 19.2 0.84 25 1.24 5.0 278 140 19.8 0.88 24 1.25 5.1 281 141 67 17.8 0.68 21 1.23 5.0 275 138 19.3 0.70 21 1.24 5.0 278 140 19.9 0.74 20 1.25 5.1 281 141 18.9 0.66 22 1.27 5.2 281 147 20.5 0.68 21 1.29 5.2 284 149 21.1 0.72 21 1.30 5.3 287 150 71 19.0 0.51 17 1.27 5.2 281 147 20.6 0.53 17 1.29 5.2 284 149 21.2 0.55 16 1.30 5.3 287 150 16.2 0.96 27 1.24 5.1 287 127 17.5 0.99 27 1.25 5.2 290 128 18.1 1.00 25 1.26 5.2 293 129 59 15.9 0.91 25 1.24 5.1 287 127 17.2 0.95 25 1.25 5.2 290 128 17.8 1.00 24 1.26 5.2 293 129 16.5 0.92 27 1.27 5.3 309 131 17.9 0.96 26 1.28 5.3 312 132 18.4 1.00 25 1.29 5.3 315 133 17.3 0.83 25 1.31 5.4 313 143 18.7 0.86 25 1.33 5.5 316 144 19.3 0.91 24 1.34 5.5 319 146 18.4 0.68 22 1.36 5.6 320 152 20.0 0.70 21 1.37 5.7 323 154 20.6 0.73 21 1.38 5.7 326 155 15.8 0.99 27 1.31 5.5 327 130 17.1 1.00 26 1.32 5.5 330 132 17.6 1.00 24 1.33 5.6 334 133 16.1 0.95 27 1.34 5.6 352 134 17.4 0.99 26 1.35 5.7 355 136 18.0 1.00 24 1.37 5.7 359 137 16.9 0.86 25 1.39 5.8 357 147 18.3 0.89 25 1.40 5.8 360 148 18.8 0.93 24 1.41 5.9 364 150 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 16.3 17.4 18.6 15.5 15.9 17.0 0.86 0.70 0.52 0.94 0.88 0.72 21 24 21 17 26 25 1.27 1.31 1.36 1.31 1.34 1.39 5.3 5.4 5.6 5.5 5.6 5.8 309 313 320 327 352 357 131 143 152 130 134 147 17.6 18.8 20.1 16.8 17.2 18.4 0.89 0.72 0.54 0.98 0.92 0.75 24 21 17 25 24 21 1.28 1.33 1.37 1.32 1.35 1.40 5.3 5.5 5.7 5.5 5.7 5.8 312 316 323 330 355 360 132 144 154 132 136 148 18.1 19.4 20.7 17.3 17.7 18.9 0.93 0.76 0.57 1.00 0.96 0.78 20 23 20 16 24 23 1.29 1.34 1.38 1.33 1.37 1.41 5.3 5.5 5.7 5.6 5.7 5.9 315 319 326 334 359 364 133 146 155 133 137 150 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 18.0 0.70 22 1.44 6.0 364 156 19.5 0.72 22 1.45 6.1 368 158 20.1 0.76 21 1.46 6.1 372 159 71 18.1 0.54 17 1.44 6.0 364 156 19.6 0.56 17 1.45 6.1 368 158 20.2 0.58 16 1.46 6.1 372 159 15.0 1.00 26 1.37 5.8 368 133 16.3 1.00 25 1.38 5.9 372 134 16.8 1.00 23 1.39 5.9 375 135 59 14.8 0.98 25 1.37 5.8 368 133 16.0 1.00 24 1.38 5.9 372 134 16.5 1.00 22 1.39 5.9 375 135 15.3 0.99 26 1.40 6.0 396 137 16.6 1.00 25 1.41 6.0 400 138 17.1 1.00 23 1.43 6.1 404 140 63 15.1 0.92 24 1.40 6.0 396 137 16.3 0.95 24 1.41 6.0 400 138 16.8 1.00 23 1.43 6.1 404 140 16.0 0.89 25 1.45 6.2 401 150 17.4 0.93 25 1.46 6.2 405 151 17.9 0.97 24 1.48 6.3 409 153 67 16.1 0.75 21 1.45 6.2 401 150 17.4 0.77 21 1.46 6.2 405 151 18.0 0.81 20 1.48 6.3 409 153 105 13.9 1.00 24 1.42 6.2 412 136 15.1 1.00 23 1.43 6.2 416 137 15.5 1.00 21 1.44 6.3 420 139 59 13.7 0.99 24 1.42 6.2 412 136 14.8 1.00 23 1.43 6.2 416 137 15.2 1.00 21 1.44 6.3 420 139 14.2 1.00 25 1.45 6.3 443 140 15.4 1.00 24 1.47 6.4 447 142 15.8 1.00 22 1.48 6.4 452 143 63 14.0 0.92 23 1.45 6.3 443 140 15.1 0.96 22 1.47 6.4 447 142 15.6 1.00 21 1.48 6.4 452 143 14.8 0.90 23 1.50 6.5 449 153 16.1 0.93 23 1.52 6.6 454 155 16.6 0.98 22 1.53 6.6 458 156 67 14.9 0.75 20 1.50 6.5 449 153 16.2 0.78 19 1.52 6.6 454 155 16.6 0.82 19 1.53 6.6 458 156 15.8 0.73 20 1.56 6.8 459 163 17.2 0.76 20 1.57 6.8 464 165 17.7 0.79 19 1.58 6.9 468 166 71 15.9 0.56 16 1.56 6.8 459 163 17.3 0.58 15 1.57 6.8 464 165 17.8 0.61 15 1.58 6.9 468 166 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 17.1 0.72 22 1.50 6.4 410 159 18.5 0.75 21 1.51 6.4 414 161 19.1 0.79 20 1.53 6.5 418 162 71 17.2 0.56 17 1.50 6.4 410 159 18.7 0.58 17 1.51 6.4 414 161 19.2 0.61 16 1.53 6.5 418 162 115 COOLING OPERATION MODEL: *SXC160241A* / CA*F3636C6** + TXV / MBVC1200**-1**, Design Subcooling @ AHRI 95°F Conditions, 5°F @ Serv. Vlv. EXPANDED PERFORMANCE DATA PERFORMANCE DATA ASXC160241A*-LOW STAGE 11 12 608 540 473 608 540 473 Airflow 59 15.5 0.66 20 1.03 4.1 194 98 16.7 0.68 19 1.05 4.2 200 101 17.2 0.71 19 1.06 4.2 202 102 15.7 0.75 23 1.04 4.1 196 99 17.0 0.77 22 1.06 4.2 202 102 17.5 0.81 22 1.07 4.3 204 103 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 16.2 0.67 21 1.06 4.2 211 106 17.5 0.69 21 1.09 4.3 217 109 18.1 0.73 20 1.09 4.4 220 110 63 16.0 0.55 17 1.05 4.2 209 105 17.4 0.57 17 1.08 4.3 215 108 17.9 0.60 16 1.09 4.3 217 109 17.5 0.50 17 1.09 4.4 223 115 19.0 0.52 17 1.12 4.5 230 119 19.5 0.55 16 1.13 4.5 232 120 67 17.6 0.38 13 1.08 4.3 220 114 19.0 0.39 13 1.11 4.4 227 118 19.6 0.41 12 1.12 4.5 229 119 18.8 0.32 12 1.13 4.5 232 123 20.4 0.34 12 1.16 4.6 239 127 21.0 0.35 11 1.17 4.7 242 128 71 15.4 0.77 23 1.12 4.4 220 105 16.6 0.80 23 1.15 4.6 227 108 17.1 0.84 22 1.16 4.6 229 109 59 15.1 0.68 20 1.11 4.4 218 104 16.4 0.70 20 1.14 4.5 224 107 16.8 0.74 19 1.15 4.6 227 108 15.8 0.69 21 1.14 4.5 237 112 17.1 0.72 21 1.17 4.7 244 115 17.6 0.75 20 1.18 4.7 246 116 63 15.6 0.57 17 1.13 4.5 234 111 17.0 0.59 17 1.16 4.6 241 114 17.5 0.62 16 1.17 4.7 244 115 75 17.1 0.52 17 1.18 4.7 250 122 18.5 0.54 17 1.21 4.8 258 126 19.1 0.57 16 1.22 4.9 260 127 67 17.1 0.39 13 1.17 4.6 247 121 18.6 0.41 13 1.20 4.8 255 124 19.1 0.43 12 1.21 4.8 258 126 18.4 0.34 12 1.22 4.9 261 130 19.9 0.35 12 1.25 5.0 269 134 20.5 0.37 11 1.26 5.0 271 135 71 15.0 0.79 23 1.19 4.8 250 109 16.2 0.82 23 1.22 4.9 258 112 16.7 0.86 22 1.23 5.0 260 114 59 14.7 0.70 20 1.18 4.8 248 108 16.0 0.72 20 1.21 4.9 255 111 16.4 0.76 19 1.22 4.9 258 112 15.4 0.71 21 1.22 4.9 269 116 16.7 0.73 21 1.25 5.0 277 120 17.2 0.77 20 1.26 5.1 280 121 16.7 0.54 17 1.26 5.1 284 127 18.1 0.56 17 1.29 5.2 293 131 18.6 0.58 16 1.30 5.3 296 132 17.9 0.35 12 1.30 5.3 296 135 19.4 0.36 12 1.33 5.4 306 139 20.0 0.38 11 1.34 5.4 309 141 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 14.6 0.82 23 1.25 5.1 285 115 15.8 0.85 23 1.29 5.3 294 118 16.3 0.89 22 1.30 5.3 297 119 15.1 0.73 21 1.28 5.2 306 122 16.3 0.76 21 1.31 5.4 316 126 16.8 0.80 20 1.33 5.4 319 127 16.3 0.55 18 1.32 5.4 324 133 17.7 0.57 17 1.36 5.6 334 137 18.2 0.60 17 1.37 5.6 337 139 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 15.3 16.7 14.4 14.9 16.3 0.58 0.40 0.72 0.60 0.42 17 13 20 17 13 1.21 1.25 1.24 1.27 1.31 4.9 5.0 5.1 5.2 5.4 266 281 282 303 320 115 125 113 121 132 16.5 18.1 15.6 16.1 17.7 0.60 0.42 0.75 0.62 0.43 17 13 20 17 13 1.24 1.28 1.27 1.30 1.35 5.0 5.2 5.2 5.3 5.5 275 290 291 313 330 118 129 117 124 136 17.0 18.7 16.0 16.6 18.2 0.63 0.44 0.78 0.65 0.45 16 12 19 16 12 1.25 1.29 1.29 1.31 1.36 5.0 5.2 5.3 5.4 5.5 277 293 294 316 334 120 131 118 126 137 17.5 0.36 12 1.37 5.6 338 142 18.9 0.37 12 1.40 5.8 348 146 19.5 0.39 11 1.42 5.8 351 148 71 - EXPANDED PERFORMANCE DATA MODEL: *SXC160241B* / CA*F3636*6**+TXV+MBVC1200**-1* LOW STAGE 13.9 0.85 23 1.31 5.4 320 120 15.0 0.88 23 1.34 5.6 330 124 15.5 0.92 22 1.35 5.6 334 125 59 13.7 0.75 20 1.30 5.4 317 119 14.8 0.77 20 1.33 5.5 327 123 15.2 0.81 19 1.34 5.6 330 124 14.3 0.76 21 1.34 5.6 345 128 15.5 0.79 21 1.37 5.7 355 132 16.0 0.83 20 1.38 5.8 359 133 63 14.2 0.62 17 1.32 5.5 341 126 15.3 0.65 17 1.36 5.7 352 130 15.8 0.68 16 1.37 5.7 355 132 15.5 0.57 17 1.38 5.7 364 139 16.8 0.60 17 1.42 5.9 375 144 17.3 0.62 16 1.43 5.9 379 145 67 15.5 0.43 13 1.37 5.7 360 138 16.8 0.45 13 1.41 5.8 372 142 17.3 0.47 12 1.42 5.9 375 144 105 12.9 0.86 21 1.35 5.7 354 124 13.9 0.89 21 1.39 5.9 365 128 14.4 0.93 20 1.40 5.9 369 129 59 12.7 0.75 19 1.34 5.7 350 123 13.7 0.78 18 1.38 5.8 361 127 14.1 0.82 17 1.39 5.9 365 128 13.2 0.77 20 1.38 5.9 381 132 14.4 0.79 19 1.42 6.0 393 136 14.8 0.83 19 1.43 6.1 397 138 63 13.1 0.63 16 1.37 5.8 377 131 14.2 0.65 16 1.41 6.0 389 135 14.6 0.68 15 1.42 6.0 393 136 14.3 0.58 16 1.43 6.1 402 144 15.5 0.60 16 1.47 6.2 415 149 16.0 0.63 15 1.48 6.3 419 150 67 14.4 0.44 12 1.42 6.0 398 143 15.6 0.45 12 1.46 6.2 411 147 16.0 0.47 11 1.47 6.2 415 149 15.4 0.37 11 1.48 6.3 420 154 16.7 0.39 11 1.52 6.5 433 158 17.2 0.41 11 1.53 6.5 437 160 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 16.6 0.37 12 1.43 5.9 380 149 18.0 0.38 12 1.47 6.1 391 153 18.5 0.40 11 1.48 6.2 395 155 71 - 115 COOLING OPERATION PERFORMANCE DATA ASXC160241B*-LOW STAGE 67 17.5 0.62 21 1.10 4.4 225 117 18.9 0.65 21 1.13 4.5 232 120 19.5 0.68 20 1.14 4.5 234 121 17.4 0.75 25 1.11 4.4 227 118 18.8 0.77 25 1.14 4.5 234 121 19.4 0.81 24 1.15 4.6 237 123 MBh 16.3 16.6 S/T 0.86 0.83 Delta T 27 27 KW 1.05 1.08 AMPS 4.2 4.3 HI PR 200 215 LO PR 101 108 MBh 17.6 18.0 S/T 0.89 0.86 Delta T 27 26 KW 1.08 1.10 AMPS 4.3 4.4 HI PR 206 222 LO PR 104 111 MBh 18.2 18.5 S/T 0.93 0.90 Delta T 25.62 25 KW 1.09 1.11 AMPS 4.4 4.4 HI PR 208 224 LO PR 106 112 59 16.0 0.82 25 1.05 4.2 198 100 17.3 0.85 25 1.07 4.3 204 103 17.9 0.89 24 1.08 4.3 206 104 63 16.3 0.77 24 1.07 4.3 213 107 17.7 0.80 24 1.09 4.4 220 110 18.2 0.83 23 1.10 4.4 222 111 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 18.5 0.61 22 1.15 4.6 237 125 20.1 0.63 21 1.18 4.7 244 129 20.7 0.66 21 1.19 4.7 247 131 71 18.7 0.47 17 1.14 4.5 235 124 20.2 0.48 17 1.17 4.7 242 128 20.8 0.51 16 1.18 4.7 244 129 15.9 0.89 27 1.14 4.5 224 107 17.2 0.92 27 1.17 4.6 231 110 17.7 0.97 26 1.18 4.7 234 112 59 15.6 0.85 26 1.13 4.5 222 106 16.9 0.88 25 1.16 4.6 229 109 17.4 0.92 24 1.17 4.6 231 110 16.2 0.86 27 1.16 4.6 241 114 17.6 0.89 27 1.19 4.7 249 117 18.1 0.93 26 1.20 4.8 251 119 63 16.0 0.79 25 1.15 4.6 239 113 17.3 0.82 24 1.18 4.7 246 116 17.8 0.86 23 1.19 4.7 249 117 17.0 0.77 26 1.20 4.8 255 124 18.4 0.80 25 1.23 4.9 263 128 18.9 0.84 24 1.24 4.9 265 130 67 17.1 0.65 21 1.19 4.7 252 123 18.5 0.67 21 1.22 4.9 260 127 19.0 0.70 20 1.23 4.9 263 128 18.1 0.63 22 1.24 4.9 266 132 19.6 0.65 22 1.27 5.1 274 137 20.2 0.68 21 1.28 5.1 277 138 71 18.2 0.48 17 1.23 4.9 263 131 19.8 0.50 17 1.26 5.0 271 135 20.3 0.53 16 1.27 5.1 274 137 15.5 0.91 28 1.21 4.9 255 111 16.8 0.94 27 1.24 5.0 263 115 17.3 0.99 26 1.25 5.1 266 116 59 15.3 0.87 26 1.20 4.8 253 110 16.5 0.90 25 1.23 5.0 260 114 17.0 0.94 24 1.24 5.0 263 115 15.8 0.88 27 1.24 5.0 275 118 17.1 0.91 27 1.27 5.1 283 122 17.7 0.96 26 1.28 5.2 286 123 16.6 0.79 26 1.28 5.2 290 129 17.9 0.82 25 1.31 5.3 299 133 18.5 0.86 24 1.32 5.3 302 135 17.7 0.64 22 1.32 5.3 302 138 19.1 0.67 22 1.36 5.5 312 142 19.7 0.70 21 1.37 5.5 315 143 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 608 540 473 608 540 473 Airflow 75 15.1 0.94 28 1.27 5.2 291 117 16.4 0.98 27 1.31 5.4 300 121 16.9 1.00 26 1.32 5.4 303 122 15.4 0.91 27 1.30 5.3 313 124 16.7 0.94 27 1.34 5.5 322 128 17.2 0.99 26 1.35 5.5 326 130 16.2 0.82 26 1.35 5.5 330 136 17.5 0.85 25 1.38 5.6 340 140 18.0 0.89 24 1.39 5.7 344 141 17.2 0.66 22 1.39 5.7 344 145 18.7 0.69 22 1.43 5.9 355 149 19.2 0.72 21 1.44 5.9 359 151 71 17.4 0.51 17 1.38 5.6 341 143 18.8 0.53 17 1.42 5.8 351 148 19.4 0.56 16 1.43 5.9 355 149 14.4 0.98 27 1.33 5.5 327 123 15.6 1.00 27 1.36 5.7 337 126 16.1 1.00 24 1.38 5.7 340 128 59 14.1 0.93 26 1.32 5.5 324 121 15.3 0.97 25 1.35 5.6 334 125 15.8 1.00 24 1.36 5.7 337 126 14.7 0.94 27 1.36 5.7 352 130 15.9 0.98 26 1.39 5.8 363 134 16.4 1.00 25 1.41 5.9 366 136 63 14.4 0.87 25 1.35 5.6 348 129 15.6 0.91 24 1.38 5.8 359 133 16.1 0.95 23 1.39 5.8 363 134 15.4 0.85 25 1.40 5.8 371 142 16.6 0.88 25 1.44 6.0 383 147 17.1 0.92 24 1.45 6.1 387 148 67 15.4 0.71 21 1.39 5.8 368 141 16.7 0.74 21 1.43 5.9 379 145 17.2 0.77 20 1.44 6.0 383 147 105 13.3 0.98 26 1.38 5.8 361 127 14.4 1.00 25 1.41 6.0 372 131 14.9 1.00 23 1.42 6.1 376 132 59 13.1 0.94 24 1.36 5.8 358 125 14.2 0.97 24 1.40 5.9 369 129 14.6 1.00 22 1.41 6.0 372 131 13.6 0.95 25 1.41 6.0 389 135 14.7 0.98 25 1.44 6.1 401 139 15.2 1.00 23 1.46 6.2 405 140 63 13.4 0.88 23 1.40 5.9 385 133 14.5 0.91 23 1.43 6.1 397 138 14.9 0.96 22 1.44 6.1 401 139 14.2 0.86 24 1.46 6.2 410 147 15.4 0.89 23 1.49 6.3 423 152 15.9 0.93 22 1.51 6.4 427 153 67 14.3 0.72 20 1.44 6.1 406 146 15.5 0.74 20 1.48 6.3 419 150 16.0 0.78 19 1.49 6.3 423 152 15.2 0.70 21 1.51 6.4 428 157 16.4 0.72 20 1.55 6.6 441 162 16.9 0.76 19 1.56 6.6 446 163 71 15.3 0.54 16 1.49 6.3 424 155 16.6 0.56 16 1.53 6.5 437 160 17.1 0.58 15 1.55 6.6 441 162 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 16.4 0.69 22 1.45 6.1 387 152 17.7 0.72 22 1.49 6.2 399 156 18.3 0.75 21 1.50 6.3 403 158 71 16.5 0.53 17 1.44 6.0 384 150 17.9 0.55 17 1.48 6.2 395 155 18.4 0.58 16 1.49 6.2 399 156 115 COOLING OPERATION Same as ASX160241C 85 80 IDB* 65 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 15.6 16.7 17.8 14.9 15.2 16.2 0.81 0.66 0.50 0.90 0.84 0.68 25 21 17 26 25 22 1.23 1.27 1.31 1.26 1.29 1.33 5.0 5.1 5.3 5.2 5.3 5.5 272 287 299 288 310 327 117 128 136 116 123 134 17.6 16.9 18.0 19.3 16.1 16.5 0.85 0.69 0.51 0.93 0.87 0.71 21 24 21 17 26 24 1.26 1.30 1.34 1.30 1.33 1.37 5.6 5.1 5.3 5.4 5.3 5.4 280 296 309 297 319 337 121 132 141 119 127 139 17.4 18.6 19.9 16.6 17.0 18.1 0.89 0.72 0.54 1.00 0.91 0.74 23 20 16 25 23 20 1.27 1.31 1.36 1.31 1.34 1.38 5.1 5.3 5.5 5.4 5.5 5.6 283 299 312 300 322 340 122 133 142 121 128 140 EXPANDED PERFORMANCE DATA MODEL: *SXC160241B* / CA*F3636*6**+TXV+MBVC1200**-1* LOW STAGE PERFORMANCE DATA ASXC160241B*-LOW STAGE 13 14 904 800 696 904 800 696 Airflow 59 22.3 0.66 19 1.47 5.7 216 117 24.2 0.68 19 1.49 5.8 218 118 24.9 0.72 18 1.50 5.8 220 119 22.7 0.75 22 1.47 5.7 216 117 24.6 0.78 22 1.49 5.8 218 118 25.3 0.81 21 1.50 5.8 220 119 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 23.4 0.67 21 1.51 5.9 232 121 25.3 0.69 20 1.52 5.9 234 122 26.1 0.73 19 1.53 6.0 237 123 63 23.1 0.55 17 1.51 5.9 232 121 25.1 0.57 16 1.52 5.9 234 122 25.8 0.60 16 1.53 6.0 237 123 25.3 0.51 17 1.55 6.0 235 132 27.4 0.53 17 1.57 6.1 238 133 28.2 0.55 16 1.58 6.2 240 134 67 25.3 0.38 13 1.55 6.0 235 132 27.5 0.40 12 1.57 6.1 238 133 28.3 0.41 12 1.58 6.2 240 134 27.2 0.33 12 1.60 6.3 241 140 29.4 0.34 11 1.62 6.3 243 142 30.3 0.35 11 1.63 6.4 245 143 71 22.2 0.78 23 1.59 6.2 244 120 24.0 0.80 22 1.60 6.2 246 122 24.7 0.84 21 1.61 6.3 249 123 59 21.8 0.68 20 1.59 6.2 244 120 23.6 0.71 19 1.60 6.2 246 122 24.3 0.74 18 1.61 6.3 249 123 22.8 0.69 21 1.62 6.3 262 124 24.7 0.72 20 1.64 6.4 265 125 25.5 0.75 20 1.65 6.4 268 127 63 22.6 0.57 17 1.62 6.3 262 124 24.5 0.59 17 1.64 6.4 265 125 25.2 0.62 16 1.65 6.4 268 127 75 24.7 0.53 17 1.67 6.5 266 136 26.8 0.54 17 1.69 6.6 269 137 27.6 0.57 16 1.70 6.6 271 138 67 24.8 0.39 13 1.67 6.5 266 136 26.8 0.41 13 1.69 6.6 269 137 27.6 0.43 12 1.70 6.6 271 138 26.5 0.34 12 1.73 6.8 272 144 28.7 0.35 12 1.74 6.8 275 146 29.6 0.37 11 1.76 6.9 277 147 71 21.6 0.80 23 1.69 6.7 277 125 23.5 0.83 22 1.70 6.7 280 126 24.2 0.87 21 1.72 6.8 283 127 59 21.3 0.70 20 1.69 6.7 277 125 23.1 0.73 19 1.70 6.7 280 126 23.8 0.76 18 1.72 6.8 283 127 22.3 0.71 21 1.73 6.8 298 128 24.1 0.74 20 1.74 6.9 301 130 24.9 0.77 20 1.75 7.0 304 131 24.1 0.54 17 1.78 7.1 303 140 26.1 0.56 17 1.80 7.1 306 142 26.9 0.59 16 1.81 7.2 309 143 25.9 0.35 12 1.84 7.3 309 149 28.0 0.36 12 1.86 7.4 312 151 28.9 0.38 11 1.87 7.4 315 152 21.1 0.82 23 1.78 7.1 316 128 22.9 0.85 22 1.79 7.2 319 129 23.6 0.89 21 1.81 7.3 322 130 21.7 0.73 21 1.82 7.3 340 132 23.6 0.76 21 1.83 7.4 343 133 24.3 0.80 20 1.85 7.4 347 135 23.5 0.56 17 1.88 7.5 345 144 25.5 0.58 17 1.89 7.6 348 145 26.3 0.60 16 1.91 7.7 352 147 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 22.1 24.2 20.8 21.5 23.6 0.58 0.40 0.72 0.60 0.42 17 13 20 17 13 1.73 1.78 1.78 1.82 1.88 6.8 7.1 7.1 7.3 7.5 298 303 316 340 345 128 140 128 132 144 23.9 26.2 22.5 23.3 25.5 0.61 0.42 0.75 0.63 0.43 17 13 19 17 13 1.74 1.80 1.79 1.83 1.89 6.9 7.1 7.2 7.4 7.6 301 306 319 343 348 130 142 129 133 145 24.6 27.0 23.2 24.0 26.3 0.64 0.44 0.79 0.66 0.45 16 12 19 16 12 1.75 1.81 1.81 1.85 1.91 7.0 7.2 7.3 7.4 7.7 304 309 322 347 352 131 143 130 135 147 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 25.3 0.36 12 1.94 7.8 352 153 27.4 0.37 12 1.96 7.9 356 155 28.2 0.39 11 1.97 7.9 359 156 71 20.1 0.85 23 1.85 7.6 341 130 21.7 0.88 22 1.87 7.6 345 132 22.4 0.93 21 1.88 7.7 348 133 59 19.7 0.75 20 1.85 7.6 341 130 21.4 0.78 19 1.87 7.6 345 132 22.0 0.82 18 1.88 7.7 348 133 20.7 0.76 21 1.89 7.8 367 134 22.4 0.79 20 1.91 7.8 371 136 23.0 0.83 19 1.93 7.9 374 137 63 20.4 0.63 17 1.89 7.8 367 134 22.2 0.65 17 1.91 7.8 371 136 22.8 0.68 16 1.93 7.9 374 137 22.4 0.58 17 1.96 8.0 372 147 24.2 0.60 17 1.97 8.1 376 148 24.9 0.63 16 1.99 8.1 380 150 67 22.4 0.43 13 1.96 8.0 372 147 24.3 0.45 13 1.97 8.1 376 148 25.0 0.47 12 1.99 8.1 380 150 105 18.6 0.86 21 1.92 8.0 404 134 20.1 0.89 21 1.93 8.1 409 135 20.7 0.93 20 1.95 8.2 413 136 59 18.3 0.76 18 1.92 8.0 404 134 19.8 0.78 18 1.93 8.1 409 135 20.4 0.82 17 1.95 8.2 413 136 19.1 0.77 19 1.96 8.2 435 138 20.7 0.80 19 1.98 8.3 439 139 21.4 0.84 18 2.00 8.3 444 141 63 18.9 0.63 16 1.96 8.2 435 138 20.5 0.65 15 1.98 8.3 439 139 21.1 0.69 15 2.00 8.3 444 141 20.7 0.58 16 2.03 8.5 441 150 22.4 0.60 16 2.04 8.5 446 152 23.1 0.63 15 2.06 8.6 450 153 67 20.8 0.44 12 2.03 8.5 441 150 22.5 0.45 12 2.04 8.5 446 152 23.2 0.48 11 2.06 8.6 450 153 22.2 0.37 11 2.10 8.8 451 160 24.1 0.39 11 2.11 8.9 455 162 24.8 0.41 10 2.13 8.9 460 163 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 24.0 0.37 12 2.02 8.3 380 156 26.0 0.38 12 2.04 8.4 384 158 26.8 0.40 11 2.06 8.4 388 160 71 - 115 COOLING OPERATION MODEL: *SXC160361A* / CA*F3743*6** + TXV / MBVC1600**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA PERFORMANCE DATA ASXC160361A*-LOW STAGE 904 800 696 904 800 696 Airflow 63 23.6 0.77 24 1.51 5.9 232 121 25.6 0.80 23 1.52 5.9 234 122 26.3 0.84 22 1.53 6.0 237 123 24.0 0.83 26 1.51 5.9 232 121 26.0 0.86 26 1.52 5.9 234 122 26.7 0.90 25 1.53 6.0 237 123 59 23.1 0.82 25 1.47 5.7 216 117 25.0 0.85 24 1.49 5.8 218 118 25.8 0.89 23 1.50 5.8 220 119 MBh 23.5 S/T 0.86 Delta T 27 KW 1.47 AMPS 5.7 216 HI PR 117 LO PR MBh 25.5 S/T 0.89 Delta T 26 KW 1.49 AMPS 5.8 HI PR 218 118 LO PR MBh 26.2 S/T 0.94 Delta T 24.97 KW 1.50 AMPS 5.8 HI PR 220 119 LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 25.1 0.75 25 1.55 6.0 235 132 27.2 0.78 24 1.57 6.1 238 133 28.0 0.82 23 1.58 6.2 240 134 67 25.2 0.63 21 1.55 6.0 235 132 27.3 0.65 20 1.57 6.1 238 133 28.1 0.68 20 1.58 6.2 240 134 26.8 0.61 22 1.60 6.3 241 140 29.0 0.63 21 1.62 6.3 243 142 29.9 0.66 20 1.63 6.4 245 143 71 27.0 0.47 17 1.60 6.3 241 140 29.2 0.49 16 1.62 6.3 243 142 30.1 0.51 16 1.63 6.4 245 143 23.0 0.89 27 1.59 6.2 244 120 24.9 0.93 26 1.60 6.2 246 122 25.6 0.97 25 1.61 6.3 249 123 59 22.6 0.85 25 1.59 6.2 244 120 24.4 0.88 25 1.60 6.2 246 122 25.2 0.93 24 1.61 6.3 249 123 23.4 0.86 27 1.62 6.3 262 124 25.4 0.89 26 1.64 6.4 265 125 26.1 0.94 25 1.65 6.4 268 127 63 23.1 0.80 24 1.62 6.3 262 124 25.0 0.83 24 1.64 6.4 265 125 25.7 0.87 23 1.65 6.4 268 127 75 24.5 0.78 25 1.67 6.5 266 136 26.6 0.81 25 1.69 6.6 269 137 27.4 0.84 24 1.70 6.6 271 138 67 24.6 0.65 21 1.67 6.5 266 136 26.7 0.67 21 1.69 6.6 269 137 27.5 0.71 20 1.70 6.6 271 138 26.2 0.63 22 1.73 6.8 272 144 28.3 0.65 21 1.74 6.8 275 146 29.2 0.69 20 1.76 6.9 277 147 71 26.3 0.49 17 1.73 6.8 272 144 28.5 0.50 17 1.74 6.8 275 146 29.4 0.53 16 1.76 6.9 277 147 22.4 0.91 27 1.69 6.7 277 125 24.3 0.95 26 1.70 6.7 280 126 25.0 0.99 25 1.72 6.8 283 127 59 22.0 0.87 25 1.69 6.7 277 125 23.9 0.90 25 1.70 6.7 280 126 24.6 0.95 24 1.72 6.8 283 127 22.8 0.88 27 1.73 6.8 298 128 24.8 0.92 26 1.74 6.9 301 130 25.5 0.96 25 1.75 7.0 304 131 23.9 0.80 25 1.78 7.1 303 140 25.9 0.83 25 1.80 7.1 306 142 26.7 0.87 24 1.81 7.2 309 143 25.5 0.65 22 1.84 7.3 309 149 27.7 0.67 21 1.86 7.4 312 151 28.5 0.70 20 1.87 7.4 315 152 21.9 0.94 27 1.78 7.1 316 128 23.7 0.98 27 1.79 7.2 319 129 24.4 1.00 25 1.81 7.3 322 130 22.3 0.91 27 1.82 7.3 340 132 24.2 0.94 26 1.83 7.4 343 133 24.9 0.99 25 1.85 7.4 347 135 23.3 0.82 25 1.88 7.5 345 144 25.3 0.85 25 1.89 7.6 348 145 26.1 0.89 24 1.91 7.7 352 147 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 22.5 24.1 25.7 21.5 22.0 23.5 0.82 0.67 0.50 0.90 0.84 0.69 24 21 17 26 25 21 1.73 1.78 1.84 1.78 1.82 1.88 6.8 7.1 7.3 7.1 7.3 7.5 298 303 309 316 340 345 128 140 149 128 132 144 24.4 26.1 27.9 23.3 23.8 25.4 0.85 0.69 0.52 0.93 0.88 0.71 24 21 17 25 24 21 1.74 1.80 1.86 1.79 1.83 1.89 6.9 7.1 7.4 7.2 7.4 7.6 301 306 312 319 343 348 130 142 151 129 133 145 25.1 26.8 28.7 24.0 24.5 26.2 0.89 0.72 0.54 1.00 0.92 0.75 23 20 16 24 23 20 1.75 1.81 1.87 1.81 1.85 1.91 7.0 7.2 7.4 7.3 7.4 7.7 304 309 315 322 347 352 131 143 152 130 135 147 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 24.9 0.67 22 1.94 7.8 352 153 27.0 0.69 21 1.96 7.9 356 155 27.8 0.73 21 1.97 7.9 359 156 71 25.1 0.51 17 1.94 7.8 352 153 27.2 0.53 17 1.96 7.9 356 155 28.0 0.56 16 1.97 7.9 359 156 20.8 0.98 27 1.85 7.6 341 130 22.5 1.00 26 1.87 7.6 345 132 23.2 1.00 24 1.88 7.7 348 133 59 20.4 0.93 25 1.85 7.6 341 130 22.1 0.97 25 1.87 7.6 345 132 22.8 1.00 23 1.88 7.7 348 133 21.2 0.95 26 1.89 7.8 367 134 22.9 0.98 26 1.91 7.8 371 136 23.6 1.00 24 1.93 7.9 374 137 63 20.9 0.88 24 1.89 7.8 367 134 22.6 0.91 24 1.91 7.8 371 136 23.3 0.95 23 1.93 7.9 374 137 22.2 0.85 25 1.96 8.0 372 147 24.0 0.89 24 1.97 8.1 376 148 24.8 0.93 23 1.99 8.1 380 150 67 22.3 0.71 21 1.96 8.0 372 147 24.1 0.74 21 1.97 8.1 376 148 24.9 0.78 20 1.99 8.1 380 150 105 19.2 0.99 25 1.92 8.0 404 134 20.8 1.00 24 1.93 8.1 409 135 21.5 1.00 22 1.95 8.2 413 136 59 18.9 0.94 24 1.92 8.0 404 134 20.5 0.98 23 1.93 8.1 409 135 21.1 1.00 21 1.95 8.2 413 136 19.6 0.95 25 1.96 8.2 435 138 21.3 0.99 24 1.98 8.3 439 139 21.9 1.00 22 2.00 8.3 444 141 63 19.3 0.88 23 1.96 8.2 435 138 20.9 0.92 22 1.98 8.3 439 139 21.6 0.96 21 2.00 8.3 444 141 20.5 0.86 23 2.03 8.5 441 150 22.3 0.89 23 2.04 8.5 446 152 22.9 0.94 22 2.06 8.6 450 153 67 20.6 0.72 20 2.03 8.5 441 150 22.4 0.75 19 2.04 8.5 446 152 23.0 0.78 18 2.06 8.6 450 153 21.9 0.70 20 2.10 8.8 451 160 23.7 0.72 20 2.11 8.9 455 162 24.5 0.76 19 2.13 8.9 460 163 71 22.1 0.54 16 2.10 8.8 451 160 23.9 0.56 15 2.11 8.9 455 162 24.6 0.58 15 2.13 8.9 460 163 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 23.7 0.69 22 2.02 8.3 380 156 25.6 0.72 21 2.04 8.4 384 158 26.4 0.75 20 2.06 8.4 388 160 71 23.8 0.53 17 2.02 8.3 380 156 25.8 0.55 16 2.04 8.4 384 158 26.6 0.58 16 2.06 8.4 388 160 115 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: *SXC160361A* / CA*F3743*6** + TXV / MBVC1600**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. PERFORMANCE DATA ASXC160361A*-LOW STAGE 15 16 878 780 683 878 780 683 Airflow 59 22.7 0.67 21 1.42 5.6 198 104 24.5 0.70 20 1.45 5.8 204 107 25.3 0.73 19 1.47 5.8 206 108 23.0 0.77 24 1.43 5.7 200 105 25.0 0.79 23 1.47 5.8 206 108 25.7 0.83 22 1.48 5.9 208 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 23.7 0.69 22 1.46 5.8 215 111 25.7 0.71 22 1.50 5.9 222 115 26.5 0.75 21 1.51 6.0 224 116 26.2 0.61 17 1.50 5.9 222 115 63 23.5 0.56 18 1.45 5.7 213 110 25.4 0.58 18 1.49 5.9 220 114 25.7 0.52 18 1.51 6.0 227 122 27.8 0.54 18 1.55 6.1 234 125 28.7 0.56 17 1.56 6.2 237 127 28.7 0.42 13 1.55 6.1 234 125 67 25.7 0.39 14 1.50 5.9 225 120 27.9 0.40 13 1.54 6.1 232 124 27.6 0.33 12 1.56 6.2 237 129 29.9 0.35 12 1.60 6.3 244 133 30.8 0.36 12 1.61 6.4 247 135 - 71 - 22.5 0.79 24 1.54 6.1 224 111 24.4 0.82 24 1.58 6.3 231 114 25.1 0.86 23 1.60 6.3 234 115 24.7 0.76 20 1.58 6.3 231 114 59 22.1 0.70 21 1.53 6.0 222 109 24.0 0.72 20 1.57 6.2 229 113 23.2 0.71 22 1.58 6.2 242 118 25.1 0.74 22 1.62 6.4 249 121 25.9 0.77 21 1.63 6.5 251 122 25.6 0.63 17 1.62 6.4 249 121 63 22.9 0.58 18 1.57 6.2 239 116 24.8 0.61 18 1.61 6.3 246 120 75 25.1 0.54 18 1.63 6.4 255 128 27.2 0.56 18 1.67 6.6 263 132 28.0 0.58 17 1.69 6.7 266 134 28.0 0.44 13 1.67 6.6 263 132 67 25.1 0.40 14 1.62 6.4 252 127 27.2 0.42 13 1.66 6.5 260 131 26.9 0.35 13 1.69 6.7 266 137 29.2 0.36 12 1.73 6.8 274 141 30.0 0.38 12 1.75 6.9 277 142 - 71 - 22.0 0.81 24 1.65 6.6 255 115 23.8 0.84 24 1.69 6.8 263 118 24.5 0.89 23 1.70 6.8 266 120 24.1 0.78 20 1.69 6.8 263 118 59 21.6 0.72 21 1.63 6.5 253 114 23.4 0.74 21 1.67 6.7 260 117 22.6 0.73 22 1.68 6.7 275 122 24.5 0.76 22 1.73 6.9 283 126 25.2 0.79 21 1.74 7.0 286 127 25.0 0.65 17 1.73 6.9 283 126 24.5 0.55 18 1.74 7.0 290 133 26.5 0.57 18 1.79 7.1 299 138 27.3 0.60 17 1.80 7.2 302 139 27.4 0.45 13 1.79 7.1 299 138 26.3 0.35 13 1.80 7.2 303 142 28.5 0.37 12 1.85 7.4 312 147 29.3 0.39 12 1.86 7.5 315 148 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 21.4 0.84 24 1.73 7.0 291 121 23.2 0.87 24 1.78 7.2 300 124 23.9 0.91 23 1.80 7.3 303 126 23.5 0.80 20 1.78 7.2 300 124 22.1 0.75 22 1.77 7.2 313 128 23.9 0.78 22 1.82 7.4 323 132 24.6 0.82 21 1.84 7.4 326 134 24.4 0.67 17 1.82 7.4 322 132 23.9 0.57 18 1.83 7.4 330 140 25.9 0.59 18 1.88 7.6 341 145 26.7 0.62 17 1.90 7.7 344 146 26.7 0.47 13 1.88 7.6 340 145 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 22.4 24.5 21.1 21.8 23.9 0.60 0.41 0.74 0.62 0.43 18 14 21 18 14 1.67 1.72 1.72 1.76 1.82 6.7 6.9 7.0 7.1 7.3 272 287 288 310 327 121 132 119 127 139 24.3 26.6 22.8 23.7 25.9 0.62 0.43 0.77 0.64 0.44 18 13 21 18 14 1.71 1.77 1.77 1.81 1.87 6.9 7.1 7.1 7.3 7.5 280 296 297 319 337 125 136 123 131 143 25.6 0.37 13 1.90 7.7 345 149 27.8 0.38 12 1.95 7.9 355 154 28.6 0.40 12 1.97 8.0 359 155 - 71 - EXPANDED PERFORMANCE DATA MODEL: *SXC160361B* / CA*F3743*6**+TXV+MBVC1600**-1* LOW STAGE 20.4 0.87 24 1.81 7.4 327 127 22.1 0.90 24 1.86 7.7 337 130 22.7 0.95 23 1.87 7.7 341 132 22.3 0.83 20 1.86 7.6 337 130 59 20.0 0.77 21 1.79 7.4 324 125 21.7 0.80 20 1.84 7.6 334 129 21.0 0.78 22 1.85 7.6 352 135 22.7 0.81 22 1.90 7.8 363 139 23.4 0.85 21 1.92 7.9 366 140 23.2 0.70 17 1.90 7.8 363 139 63 20.8 0.64 18 1.84 7.6 348 133 22.5 0.66 18 1.88 7.8 359 137 22.7 0.59 18 1.92 7.9 372 147 24.6 0.61 18 1.97 8.1 383 151 25.3 0.64 17 1.98 8.2 387 153 25.4 0.48 13 1.97 8.1 383 151 67 22.7 0.44 14 1.90 7.8 368 145 24.6 0.46 13 1.95 8.0 379 150 105 18.9 0.88 22 1.88 7.9 361 131 20.4 0.91 22 1.93 8.1 373 135 21.0 0.96 21 1.94 8.2 376 136 20.7 0.84 18 1.93 8.1 372 135 59 18.5 0.77 19 1.86 7.8 358 130 20.1 0.80 19 1.91 8.0 369 134 19.4 0.79 21 1.92 8.1 389 139 21.0 0.82 20 1.97 8.3 401 144 21.7 0.86 19 1.99 8.4 405 145 21.5 0.70 16 1.97 8.3 401 143 63 19.2 0.65 17 1.90 8.0 385 138 20.8 0.67 16 1.95 8.2 397 142 21.0 0.60 17 1.99 8.3 411 152 22.8 0.62 17 2.04 8.5 423 157 23.5 0.65 16 2.06 8.6 428 158 23.5 0.49 12 2.04 8.5 423 157 67 21.1 0.45 13 1.97 8.2 406 150 22.8 0.46 12 2.02 8.5 419 155 22.6 0.38 12 2.05 8.6 428 162 24.4 0.40 11 2.11 8.9 442 167 25.2 0.42 11 2.13 8.9 446 169 - 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 24.4 0.38 12 1.98 8.2 388 156 26.4 0.39 12 2.04 8.4 400 161 27.2 0.41 12 2.05 8.5 404 163 - 71 - 115 COOLING OPERATION PERFORMANCE DATA ASXC160361B*-LOW STAGE 878 780 683 878 780 683 Airflow 67 25.6 0.64 22 1.52 6.0 230 123 27.7 0.67 22 1.56 6.2 237 127 28.6 0.70 21 1.57 6.2 239 128 25.5 0.77 26 1.54 6.1 232 124 27.6 0.80 26 1.57 6.2 239 128 28.4 0.83 25 1.59 6.3 241 129 MBh 23.9 24.3 S/T 0.88 0.85 Delta T 28 28 KW 1.45 1.49 AMPS 5.8 5.9 HI PR 204 220 LO PR 107 114 MBh 25.8 26.3 S/T 0.91 0.88 Delta T 28 27 KW 1.49 1.52 AMPS 5.9 6.0 HI PR 210 226 LO PR 110 117 MBh 26.6 27.1 S/T 0.96 0.92 Delta T 26.73 26 KW 1.50 1.54 AMPS 6.0 6.1 HI PR 212 229 LO PR 111 118 59 23.4 0.84 27 1.44 5.7 202 106 25.4 0.87 26 1.48 5.9 208 109 26.2 0.91 25 1.49 5.9 210 110 63 24.0 0.79 25 1.47 5.8 217 112 26.0 0.82 25 1.51 6.0 224 116 26.7 0.86 24 1.52 6.0 226 117 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 27.2 0.62 23 1.59 6.3 242 132 29.4 0.65 22 1.63 6.4 249 136 30.3 0.68 22 1.64 6.5 252 138 71 27.4 0.48 18 1.57 6.2 239 131 29.6 0.50 17 1.61 6.4 247 135 30.5 0.52 17 1.63 6.4 249 136 23.3 0.91 29 1.57 6.2 229 113 25.2 0.95 28 1.61 6.4 236 116 26.0 0.99 27 1.63 6.4 238 117 59 22.9 0.87 27 1.56 6.1 227 112 24.8 0.90 26 1.60 6.3 234 115 25.6 0.95 25 1.61 6.4 236 116 23.8 0.88 28 1.61 6.3 246 120 25.7 0.91 28 1.65 6.5 254 124 26.5 0.96 27 1.66 6.6 257 125 63 23.4 0.82 26 1.59 6.3 244 119 25.4 0.85 25 1.63 6.5 251 123 26.1 0.89 24 1.65 6.5 254 124 75 24.9 0.80 27 1.66 6.5 260 131 27.0 0.82 26 1.70 6.7 268 135 27.8 0.86 25 1.72 6.8 271 136 67 25.0 0.67 22 1.65 6.5 258 130 27.1 0.69 22 1.69 6.7 266 134 27.9 0.72 21 1.70 6.7 268 135 26.5 0.65 23 1.72 6.8 271 140 28.8 0.67 23 1.76 7.0 280 144 29.6 0.70 22 1.78 7.0 283 145 71 26.7 0.50 18 1.70 6.7 269 138 29.0 0.52 18 1.75 6.9 277 142 29.8 0.54 17 1.76 7.0 280 144 22.7 0.94 29 1.67 6.7 260 117 24.6 0.97 28 1.72 6.9 268 121 25.4 1.00 27 1.73 6.9 271 122 59 22.4 0.89 27 1.66 6.6 258 116 24.2 0.93 26 1.70 6.8 266 120 25.0 1.00 26 1.72 6.9 268 121 23.2 0.90 28 1.71 6.9 280 125 25.1 0.94 28 1.76 7.0 289 129 25.9 0.98 27 1.77 7.1 292 130 24.3 0.82 27 1.77 7.1 296 136 26.3 0.85 26 1.82 7.3 305 140 27.1 0.89 25 1.83 7.3 308 142 25.9 0.66 23 1.83 7.3 309 145 28.1 0.69 23 1.88 7.5 318 150 28.9 0.72 22 1.90 7.6 321 151 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 22.2 0.97 29 1.76 7.1 297 123 24.0 1.00 28 1.81 7.3 306 127 24.8 1.00 26 1.83 7.4 309 128 22.6 0.93 28 1.81 7.3 319 131 24.5 0.97 28 1.85 7.5 329 135 25.2 1.00 26 1.87 7.6 332 136 23.7 0.84 27 1.87 7.5 337 143 25.7 0.87 26 1.92 7.7 347 147 26.4 0.92 25 1.93 7.8 351 149 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 22.8 24.4 26.1 21.8 22.3 23.8 0.84 0.68 0.51 0.92 0.86 0.70 26 22 18 27 26 23 1.70 1.75 1.81 1.75 1.79 1.85 6.8 7.0 7.3 7.1 7.2 7.5 277 293 306 294 316 334 123 135 144 122 130 142 25.8 24.8 26.4 28.3 23.6 24.1 0.87 0.71 0.53 0.96 0.90 0.73 22 25 22 18 27 26 1.74 1.80 1.86 1.80 1.84 1.90 7.7 7.0 7.2 7.5 7.3 7.4 286 302 315 303 326 344 127 139 148 126 134 146 25.5 27.2 29.1 24.3 24.9 26.6 0.91 0.74 0.55 1.00 0.94 0.77 24 21 17 26 25 21 1.76 1.82 1.88 1.81 1.85 1.92 7.0 7.3 7.5 7.3 7.5 7.7 289 305 318 306 329 347 129 140 150 127 135 147 25.3 0.68 23 1.93 7.8 352 152 27.4 0.71 23 1.98 8.0 362 157 28.2 0.74 22 2.00 8.1 366 159 71 25.5 0.53 18 1.91 7.7 348 151 27.6 0.55 18 1.97 8.0 359 155 28.4 0.57 17 1.98 8.0 362 157 EXPANDED PERFORMANCE DATA MODEL: *SXC160361B* / CA*F3743*6**+TXV+MBVC1600**-1* LOW STAGE 21.1 1.00 28 1.84 7.6 334 129 22.8 1.00 27 1.89 7.8 344 133 23.5 1.00 25 1.91 7.9 347 134 59 20.7 0.96 27 1.83 7.5 330 128 22.5 0.99 26 1.87 7.7 341 132 23.1 1.00 24 1.89 7.8 344 133 21.5 0.97 28 1.88 7.8 359 137 23.3 1.00 27 1.93 8.0 370 142 24.0 1.00 25 1.95 8.0 374 143 63 21.2 0.90 26 1.87 7.7 355 136 22.9 0.93 25 1.92 7.9 366 140 23.6 1.00 25 1.93 8.0 370 142 22.5 0.87 26 1.95 8.0 379 150 24.4 0.91 26 2.00 8.2 391 155 25.1 0.95 25 2.02 8.3 395 156 67 22.6 0.73 22 1.93 7.9 375 148 24.5 0.76 22 1.98 8.2 387 153 25.2 0.79 21 2.00 8.2 391 155 105 19.5 1.00 26 1.91 8.0 369 133 21.2 1.00 25 1.96 8.2 380 138 21.8 1.00 23 1.98 8.3 384 139 59 19.2 0.97 25 1.89 7.9 365 132 20.8 1.00 25 1.94 8.2 376 136 21.4 1.00 22 1.96 8.2 380 138 19.9 0.98 26 1.95 8.2 397 142 21.6 1.00 25 2.01 8.4 409 146 22.2 1.00 23 2.02 8.5 413 148 63 19.6 0.91 24 1.94 8.1 393 141 21.3 0.94 24 1.99 8.4 405 145 21.9 1.00 23 2.01 8.4 409 146 20.9 0.88 25 2.02 8.5 419 155 22.6 0.91 24 2.07 8.7 432 160 23.3 0.96 23 2.09 8.8 436 161 67 21.0 0.74 21 2.00 8.4 415 154 22.7 0.76 20 2.06 8.6 428 158 23.4 0.80 20 2.07 8.7 432 160 22.2 0.71 21 2.09 8.8 437 165 24.1 0.74 21 2.15 9.0 450 170 24.8 0.78 20 2.17 9.1 455 172 71 22.4 0.55 17 2.07 8.7 433 163 24.3 0.57 16 2.13 8.9 446 169 25.0 0.60 16 2.15 9.0 450 170 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 24.0 0.71 23 2.02 8.3 395 160 26.0 0.74 23 2.07 8.5 408 165 26.8 0.77 22 2.09 8.6 412 166 71 24.2 0.55 18 2.00 8.2 392 158 26.2 0.57 17 2.05 8.5 404 163 27.0 0.59 17 2.07 8.5 408 165 115 COOLING OPERATION PERFORMANCE DATA ASXC160361B*-LOW STAGE 17 18 1238 1100 963 1238 1100 963 Airflow 59 30.4 0.67 20 2.01 8.0 223 119 32.9 0.70 19 2.03 8.1 225 120 33.9 0.73 18 2.04 8.1 227 122 30.9 0.77 23 2.01 8.0 223 119 33.5 0.79 22 2.03 8.1 225 120 34.5 0.83 21 2.04 8.1 227 122 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 31.8 0.69 21 2.05 8.2 239 123 34.5 0.71 20 2.07 8.2 242 124 35.5 0.75 20 2.09 8.3 244 125 63 31.5 0.56 17 2.05 8.2 239 123 34.1 0.58 17 2.07 8.2 242 124 35.2 0.61 16 2.09 8.3 244 125 34.4 0.52 17 2.12 8.4 243 134 37.3 0.54 17 2.14 8.5 245 136 38.4 0.56 16 2.16 8.6 248 137 67 34.5 0.39 13 2.12 8.4 243 134 37.4 0.40 13 2.14 8.5 245 136 38.5 0.42 12 2.16 8.6 248 137 37.0 0.33 12 2.19 8.7 248 143 40.1 0.35 12 2.21 8.8 251 144 41.3 0.36 11 2.23 8.9 253 146 71 30.2 0.79 23 2.17 8.6 252 123 32.7 0.82 23 2.19 8.7 254 124 33.7 0.86 22 2.21 8.8 257 125 59 29.7 0.70 20 2.17 8.6 252 123 32.2 0.72 19 2.19 8.7 254 124 33.1 0.76 19 2.21 8.8 257 125 31.1 0.71 21 2.22 8.8 270 127 33.7 0.74 21 2.24 8.9 273 128 34.7 0.77 20 2.26 9.0 276 129 63 30.8 0.58 17 2.22 8.8 270 127 33.3 0.61 17 2.24 8.9 273 128 34.3 0.63 16 2.26 9.0 276 129 75 33.6 0.54 17 2.29 9.1 274 138 36.4 0.56 17 2.31 9.2 277 140 37.5 0.58 16 2.33 9.3 280 141 67 33.7 0.40 13 2.29 9.1 274 138 36.5 0.42 13 2.31 9.2 277 140 37.6 0.44 12 2.33 9.3 280 141 36.1 0.35 12 2.37 9.4 280 147 39.1 0.36 12 2.39 9.5 283 149 40.3 0.38 11 2.41 9.6 286 150 71 29.5 0.81 23 2.31 9.3 286 127 31.9 0.84 23 2.33 9.4 289 128 32.9 0.89 22 2.35 9.5 292 129 59 29.0 0.72 20 2.31 9.3 286 127 31.4 0.74 19 2.33 9.4 289 128 32.3 0.78 19 2.35 9.5 292 129 30.3 0.73 21 2.36 9.6 308 131 32.9 0.76 21 2.38 9.6 311 132 33.9 0.79 20 2.41 9.7 314 134 32.8 0.55 17 2.44 9.9 312 143 35.6 0.57 17 2.47 10.0 315 144 36.6 0.60 16 2.49 10.0 318 146 35.2 0.35 12 2.53 10.2 319 152 38.2 0.37 12 2.55 10.3 322 154 39.3 0.39 11 2.57 10.4 325 155 28.8 0.84 23 2.44 10.0 326 130 31.1 0.87 23 2.46 10.1 329 132 32.1 0.91 22 2.48 10.1 332 133 29.6 0.75 21 2.49 10.2 350 134 32.1 0.78 21 2.51 10.3 354 136 33.0 0.82 20 2.54 10.4 357 137 32.0 0.57 17 2.58 10.5 355 147 34.7 0.59 17 2.60 10.6 359 148 35.8 0.62 16 2.62 10.7 362 150 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 30.0 32.9 28.3 29.3 32.1 0.60 0.41 0.74 0.62 0.43 17 13 20 17 13 2.36 2.44 2.44 2.49 2.58 9.6 9.9 10.0 10.2 10.5 308 312 326 350 355 131 143 130 134 147 32.5 35.7 30.6 31.7 34.8 0.62 0.43 0.77 0.64 0.44 17 13 20 17 13 2.38 2.47 2.46 2.51 2.60 9.6 10.0 10.1 10.3 10.6 311 315 329 354 359 132 144 132 136 148 33.5 36.7 31.5 32.7 35.8 0.65 0.45 0.80 0.67 0.47 16 12 19 16 12 2.41 2.49 2.48 2.54 2.62 9.7 10.0 10.1 10.4 10.7 314 318 332 357 362 134 146 133 137 150 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 34.4 0.37 12 2.67 10.9 363 156 37.3 0.38 12 2.69 11.0 367 158 38.4 0.40 11 2.71 11.1 370 159 71 27.3 0.87 23 2.54 10.6 367 133 29.6 0.90 22 2.57 10.7 370 134 30.5 0.95 21 2.59 10.8 374 136 59 26.9 0.77 20 2.54 10.6 367 133 29.1 0.80 19 2.57 10.7 370 134 30.0 0.83 19 2.59 10.8 374 136 28.1 0.78 21 2.60 10.8 394 137 30.5 0.81 21 2.62 10.9 398 138 31.4 0.85 20 2.65 11.0 402 140 63 27.8 0.64 17 2.60 10.8 394 137 30.2 0.66 17 2.62 10.9 398 138 31.1 0.70 16 2.65 11.0 402 140 30.4 0.59 17 2.69 11.2 400 150 33.0 0.61 17 2.71 11.3 404 151 34.0 0.64 16 2.74 11.4 408 153 67 30.5 0.44 13 2.69 11.2 400 150 33.0 0.46 13 2.71 11.3 404 151 34.0 0.48 12 2.74 11.4 408 153 105 25.3 0.88 21 2.64 11.2 411 136 27.4 0.91 21 2.66 11.3 415 138 28.2 0.96 20 2.68 11.4 419 139 59 24.9 0.77 18 2.64 11.2 411 136 27.0 0.80 18 2.66 11.3 415 138 27.8 0.84 17 2.68 11.4 419 139 26.0 0.79 20 2.70 11.5 441 140 28.2 0.82 19 2.72 11.6 446 142 29.1 0.86 18 2.74 11.7 450 143 63 25.8 0.65 16 2.70 11.5 441 140 27.9 0.67 16 2.72 11.6 446 142 28.8 0.70 15 2.74 11.7 450 143 28.2 0.60 16 2.79 11.9 448 153 30.5 0.62 16 2.81 12.0 452 155 31.5 0.65 15 2.84 12.1 457 156 67 28.3 0.45 12 2.79 11.9 448 153 30.6 0.46 12 2.81 12.0 452 155 31.5 0.49 11 2.84 12.1 457 156 30.3 0.38 11 2.89 12.3 458 163 32.8 0.40 11 2.91 12.4 462 165 33.8 0.42 10 2.94 12.5 467 167 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 32.7 0.38 12 2.78 11.6 409 159 35.4 0.39 12 2.81 11.7 413 161 36.5 0.41 11 2.83 11.8 417 163 71 - 115 COOLING OPERATION MODEL: *SXC160481A* / CA*F4961*6** + TXV / MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA PERFORMANCE DATA A/DSXC160481A*-LOW STAGE 1238 1100 963 1238 1100 963 Airflow 67 34.3 0.64 21 2.12 8.4 243 134 37.2 0.67 21 2.14 8.5 245 136 38.3 0.70 20 2.16 8.6 248 137 34.2 0.77 25 2.12 8.4 243 134 37.0 0.80 25 2.14 8.5 245 136 38.1 0.83 24 2.16 8.6 248 137 MBh 32.0 32.6 S/T 0.88 0.85 Delta T 27 26 KW 2.01 2.05 AMPS 8.0 8.2 HI PR 223 239 LO PR 119 123 MBh 34.7 35.3 S/T 0.91 0.88 Delta T 26 26 KW 2.03 2.07 AMPS 8.1 8.2 HI PR 225 242 LO PR 120 124 MBh 35.7 36.4 S/T 0.96 0.92 Delta T 25.42 25 KW 2.04 2.09 AMPS 8.1 8.3 HI PR 227 244 LO PR 122 125 59 31.5 0.84 25 2.01 8.0 223 119 34.1 0.87 25 2.03 8.1 225 120 35.1 0.91 24 2.04 8.1 227 122 63 32.1 0.79 24 2.05 8.2 239 123 34.8 0.82 24 2.07 8.2 242 124 35.9 0.86 23 2.09 8.3 244 125 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 36.5 0.62 22 2.19 8.7 248 143 39.5 0.65 21 2.21 8.8 251 144 40.7 0.68 20 2.23 8.9 253 146 71 36.7 0.48 17 2.19 8.7 248 143 39.8 0.50 17 2.21 8.8 251 144 41.0 0.52 16 2.23 8.9 253 146 31.3 0.91 27 2.17 8.6 252 123 33.9 0.95 27 2.19 8.7 254 124 34.9 0.99 26 2.21 8.8 257 125 59 30.7 0.87 26 2.17 8.6 252 123 33.3 0.90 25 2.19 8.7 254 124 34.3 0.95 24 2.21 8.8 257 125 31.9 0.88 27 2.22 8.8 270 127 34.5 0.91 26 2.24 8.9 273 128 35.6 0.96 25 2.26 9.0 276 129 63 31.4 0.82 24 2.22 8.8 270 127 34.0 0.85 24 2.24 8.9 273 128 35.0 0.89 23 2.26 9.0 276 129 75 33.4 0.80 25 2.29 9.1 274 138 36.2 0.82 25 2.31 9.2 277 140 37.2 0.86 24 2.33 9.3 280 141 67 33.5 0.66 21 2.29 9.1 274 138 36.3 0.69 21 2.31 9.2 277 140 37.4 0.72 20 2.33 9.3 280 141 35.6 0.65 22 2.37 9.4 280 147 38.6 0.67 22 2.39 9.5 283 149 39.7 0.70 21 2.41 9.6 286 150 71 35.9 0.50 17 2.37 9.4 280 147 38.8 0.52 17 2.39 9.5 283 149 40.0 0.54 16 2.41 9.6 286 150 30.5 0.94 27 2.31 9.3 286 127 33.1 0.97 27 2.33 9.4 289 128 34.1 1.00 25 2.35 9.5 292 129 59 30.0 0.89 26 2.31 9.3 286 127 32.5 0.93 25 2.33 9.4 289 128 33.5 1.00 25 2.35 9.5 292 129 31.1 0.90 27 2.36 9.6 308 131 33.7 0.94 26 2.38 9.6 311 132 34.7 0.98 25 2.41 9.7 314 134 32.6 0.82 25 2.44 9.9 312 143 35.3 0.85 25 2.47 10.0 315 144 36.4 0.89 24 2.49 10.0 318 146 34.8 0.66 22 2.53 10.2 319 152 37.7 0.69 22 2.55 10.3 322 154 38.8 0.72 21 2.57 10.4 325 155 29.8 0.97 27 2.44 10.0 326 130 32.3 1.00 27 2.46 10.1 329 132 33.2 1.00 25 2.48 10.1 332 133 30.3 0.93 27 2.49 10.2 350 134 32.9 0.97 27 2.51 10.3 354 136 33.9 1.00 25 2.54 10.4 357 137 31.8 0.84 26 2.58 10.5 355 147 34.4 0.87 25 2.60 10.6 359 148 35.5 0.92 24 2.62 10.7 362 150 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 30.6 32.7 35.0 29.3 29.9 31.9 0.84 0.68 0.51 0.92 0.86 0.70 25 21 17 26 25 21 2.36 2.44 2.53 2.44 2.49 2.58 9.6 9.9 10.2 10.0 10.2 10.5 308 312 319 326 350 355 131 143 152 130 134 147 33.2 35.5 37.9 31.7 32.4 34.6 0.87 0.71 0.53 0.96 0.90 0.73 24 21 17 25 24 21 2.38 2.47 2.55 2.46 2.51 2.60 9.6 10.0 10.3 10.1 10.3 10.6 311 315 322 329 354 359 132 144 154 132 136 148 34.2 36.5 39.1 32.7 33.4 35.6 0.91 0.74 0.55 1.00 0.94 0.77 23 20 16 24 23 20 2.41 2.49 2.57 2.48 2.54 2.62 9.7 10.0 10.4 10.1 10.4 10.7 314 318 325 332 357 362 134 146 155 133 137 150 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 33.9 0.68 22 2.67 10.9 363 156 36.7 0.71 22 2.69 11.0 367 158 37.8 0.74 21 2.71 11.1 370 159 71 34.1 0.53 17 2.67 10.9 363 156 37.0 0.55 17 2.69 11.0 367 158 38.1 0.57 16 2.71 11.1 370 159 28.3 1.00 27 2.54 10.6 367 133 30.6 1.00 26 2.57 10.7 370 134 31.6 1.00 23 2.59 10.8 374 136 59 27.8 0.96 25 2.54 10.6 367 133 30.1 0.99 25 2.57 10.7 370 134 31.0 1.00 23 2.59 10.8 374 136 28.8 0.97 27 2.60 10.8 394 137 31.2 1.00 26 2.62 10.9 398 138 32.2 1.00 24 2.65 11.0 402 140 63 28.4 0.90 24 2.60 10.8 394 137 30.8 0.93 24 2.62 10.9 398 138 31.7 1.00 24 2.65 11.0 402 140 30.2 0.87 25 2.69 11.2 400 150 32.7 0.91 25 2.71 11.3 404 151 33.7 0.95 24 2.74 11.4 408 153 67 30.3 0.73 21 2.69 11.2 400 150 32.9 0.76 21 2.71 11.3 404 151 33.9 0.79 20 2.74 11.4 408 153 105 26.2 1.00 25 2.64 11.2 411 136 28.4 1.00 24 2.66 11.3 415 138 29.2 1.00 22 2.68 11.4 419 139 59 25.8 0.96 24 2.64 11.2 411 136 27.9 1.00 23 2.66 11.3 415 138 28.7 1.00 21 2.68 11.4 419 139 26.7 0.98 25 2.70 11.5 441 140 28.9 1.00 24 2.72 11.6 446 142 29.8 1.00 22 2.74 11.7 450 143 63 26.3 0.90 23 2.70 11.5 441 140 28.5 0.94 22 2.72 11.6 446 142 29.4 1.00 22 2.74 11.7 450 143 28.0 0.88 24 2.79 11.9 448 153 30.3 0.91 23 2.81 12.0 452 155 31.2 0.96 22 2.84 12.1 457 156 67 28.1 0.74 20 2.79 11.9 448 153 30.5 0.76 19 2.81 12.0 452 155 31.4 0.80 19 2.84 12.1 457 156 29.8 0.71 20 2.89 12.3 458 163 32.3 0.74 20 2.91 12.4 462 165 33.3 0.78 19 2.94 12.5 467 167 71 30.1 0.55 16 2.89 12.3 458 163 32.6 0.57 16 2.91 12.4 462 165 33.5 0.60 15 2.94 12.5 467 167 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 32.2 0.71 22 2.78 11.6 409 159 34.9 0.73 21 2.81 11.7 413 161 35.9 0.77 21 2.83 11.8 417 163 71 32.4 0.55 17 2.78 11.6 409 159 35.1 0.57 17 2.81 11.7 413 161 36.2 0.59 16 2.83 11.8 417 163 115 COOLING OPERATION MODEL: *SXC160481A* / CA*F4961*6** + TXV / MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA PERFORMANCE DATA A/DSXC160481A*-LOW STAGE 19 20 1238 1100 963 1238 1100 963 Airflow 59 30.7 0.68 20 1.97 9.5 207 102 33.3 0.71 20 2.02 9.7 214 106 34.3 0.74 19 2.04 9.8 216 107 31.3 0.78 23 1.99 9.6 209 104 33.9 0.81 23 2.04 9.8 216 107 34.9 0.84 22 2.06 9.9 218 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 32.2 0.69 21 2.03 9.7 225 110 34.9 0.72 21 2.08 10.0 232 114 35.9 0.76 20 2.10 10.0 235 115 63 31.9 0.57 17 2.02 9.7 223 109 34.5 0.59 17 2.07 9.9 230 112 35.5 0.62 16 2.08 10.0 232 114 34.8 0.53 17 2.10 10.0 238 120 37.7 0.55 17 2.15 10.2 245 124 38.9 0.57 17 2.17 10.3 248 125 67 34.9 0.40 13 2.08 9.9 235 119 37.8 0.41 13 2.13 10.2 243 123 38.9 0.43 12 2.15 10.2 245 124 37.4 0.34 12 2.17 10.3 248 128 40.5 0.35 12 2.22 10.6 256 132 41.7 0.37 11 2.24 10.6 258 133 71 30.5 0.81 23 2.14 10.2 235 109 33.1 0.84 23 2.20 10.4 242 113 34.1 0.88 22 2.22 10.5 245 114 59 30.0 0.71 20 2.13 10.1 232 108 32.5 0.73 20 2.18 10.4 240 112 33.5 0.77 19 2.20 10.4 242 113 31.4 0.72 22 2.19 10.4 253 116 34.1 0.75 21 2.25 10.6 261 120 35.1 0.78 20 2.27 10.7 263 121 63 31.1 0.59 18 2.17 10.3 250 115 33.7 0.61 17 2.23 10.6 258 119 34.7 0.64 17 2.25 10.6 261 120 75 34.0 0.55 18 2.26 10.7 267 127 36.9 0.57 17 2.32 10.9 275 131 38.0 0.59 17 2.34 11.0 278 132 67 34.1 0.41 13 2.24 10.6 264 126 36.9 0.43 13 2.30 10.9 272 130 38.0 0.45 13 2.32 10.9 275 131 36.5 0.35 12 2.34 11.0 278 135 39.6 0.36 12 2.40 11.3 287 139 40.7 0.38 12 2.42 11.4 290 141 71 29.8 0.83 24 2.28 10.9 267 114 32.3 0.86 23 2.34 11.2 275 117 33.3 0.90 22 2.36 11.3 278 118 59 29.3 0.73 20 2.26 10.8 264 113 31.7 0.75 20 2.32 11.1 273 116 32.7 0.79 19 2.34 11.2 275 117 30.7 0.74 22 2.33 11.2 287 121 33.2 0.77 21 2.39 11.4 296 125 34.2 0.80 20 2.41 11.5 299 126 33.2 0.56 18 2.41 11.5 304 132 36.0 0.58 17 2.47 11.8 313 136 37.1 0.61 17 2.49 11.8 316 137 35.6 0.36 12 2.49 11.8 317 141 38.6 0.37 12 2.55 12.1 326 145 39.8 0.39 12 2.57 12.2 330 146 29.1 0.85 24 2.40 11.6 304 119 31.5 0.88 23 2.46 11.9 314 123 32.4 0.93 22 2.48 11.9 317 124 29.9 0.76 22 2.45 11.8 327 127 32.4 0.79 21 2.52 12.1 338 131 33.4 0.83 21 2.54 12.2 341 132 32.4 0.58 18 2.54 12.2 346 139 35.1 0.60 18 2.60 12.5 356 143 36.2 0.63 17 2.62 12.6 360 144 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 30.4 33.3 28.6 29.6 32.5 0.61 0.42 0.75 0.63 0.43 18 13 20 18 13 2.31 2.39 2.38 2.43 2.51 11.1 11.4 11.5 11.7 12.1 285 300 301 324 342 120 131 118 126 137 32.9 36.1 31.0 32.1 35.2 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 2.37 2.45 2.44 2.50 2.58 11.3 11.7 11.8 12.0 12.4 293 310 310 334 353 123 135 122 130 142 33.9 37.1 31.9 33.1 36.2 0.66 0.46 0.82 0.68 0.47 17 13 19 17 13 2.39 2.47 2.46 2.52 2.60 11.4 11.8 11.9 12.1 12.5 296 313 314 337 356 125 136 123 131 143 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 MODEL: *SXC160481B* / CA*F4860*6** + TXV / MBVC2000**-1** 34.8 0.37 12 2.62 12.6 361 148 37.7 0.38 12 2.69 12.9 372 152 38.8 0.40 12 2.71 13.0 375 154 71 - EXPANDED PERFORMANCE DATA 27.6 0.88 23 2.50 12.2 342 125 29.9 0.92 23 2.57 12.5 353 129 30.8 0.96 22 2.59 12.6 356 130 59 27.2 0.78 20 2.48 12.1 339 124 29.4 0.81 20 2.55 12.4 349 128 30.3 0.85 19 2.57 12.5 353 129 28.4 0.79 21 2.56 12.5 368 133 30.8 0.82 21 2.63 12.8 380 137 31.7 0.86 20 2.65 12.9 383 139 63 28.2 0.65 17 2.54 12.4 365 132 30.5 0.67 17 2.60 12.7 376 136 31.4 0.71 16 2.63 12.8 380 137 30.8 0.60 18 2.64 12.8 389 145 33.3 0.62 17 2.71 13.2 401 150 34.4 0.65 17 2.74 13.3 405 151 67 30.8 0.45 13 2.62 12.7 385 144 33.4 0.47 13 2.69 13.0 397 148 34.4 0.49 13 2.71 13.2 401 150 105 25.6 0.89 22 2.59 12.8 378 129 27.7 0.93 21 2.66 13.2 390 133 28.6 0.97 21 2.68 13.3 394 135 59 25.2 0.78 19 2.57 12.7 374 128 27.3 0.81 19 2.64 13.1 386 132 28.1 0.85 18 2.66 13.2 390 133 26.3 0.80 20 2.65 13.1 407 138 28.5 0.83 20 2.72 13.4 420 142 29.4 0.87 19 2.74 13.6 424 143 63 26.1 0.66 16 2.63 13.0 403 136 28.3 0.68 16 2.70 13.3 415 141 29.1 0.71 15 2.72 13.4 419 142 28.5 0.60 16 2.74 13.5 430 150 30.9 0.63 16 2.81 13.8 443 155 31.8 0.66 16 2.83 14.0 447 157 67 28.6 0.45 12 2.71 13.4 425 149 31.0 0.47 12 2.79 13.7 439 153 31.9 0.49 12 2.81 13.8 443 155 30.6 0.39 11 2.83 14.0 448 160 33.2 0.40 11 2.91 14.3 462 165 34.2 0.42 11 2.93 14.4 467 167 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 33.0 0.39 12 2.73 13.3 406 155 35.8 0.40 12 2.81 13.6 418 160 36.9 0.42 11 2.83 13.7 422 161 71 - 115 COOLING OPERATION PERFORMANCE DATA *SXC160481B*-LOW STAGE 1238 1100 963 1238 1100 963 Airflow 67 34.7 0.65 22 2.11 10.1 240 121 37.6 0.67 21 2.17 10.3 248 125 38.8 0.71 20 2.19 10.4 250 126 34.6 0.78 26 2.13 10.2 243 123 37.4 0.81 25 2.19 10.4 250 126 38.6 0.85 24 2.20 10.5 253 128 MBh 32.4 33.0 S/T 0.89 0.86 Delta T 28 27 KW 2.02 2.07 AMPS 9.7 9.9 214 230 HI PR LO PR 106 112 MBh 35.1 35.7 S/T 0.93 0.89 Delta T 27 27 KW 2.07 2.12 AMPS 9.9 10.1 HI PR 220 237 LO PR 109 116 MBh 36.1 36.8 S/T 0.97 0.94 Delta T 26.07 26 KW 2.09 2.13 AMPS 10.0 10.2 HI PR 222 239 LO PR 110 117 59 31.8 0.85 26 2.01 9.6 211 105 34.5 0.88 25 2.06 9.9 218 108 35.5 0.93 24 2.07 9.9 220 109 63 32.5 0.80 25 2.05 9.8 228 111 35.2 0.83 24 2.10 10.0 235 115 36.3 0.87 23 2.12 10.1 237 116 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 36.9 0.63 22 2.20 10.5 253 131 39.9 0.65 22 2.26 10.7 261 135 41.1 0.69 21 2.28 10.8 264 136 71 37.1 0.49 17 2.18 10.4 251 129 40.2 0.50 17 2.24 10.6 258 133 41.4 0.53 16 2.26 10.7 261 135 31.6 0.93 28 2.18 10.4 240 112 34.3 0.96 27 2.24 10.6 247 115 35.3 1.00 26 2.25 10.7 249 116 59 31.1 0.88 26 2.16 10.3 237 110 33.7 0.92 26 2.22 10.5 245 114 34.7 0.96 25 2.24 10.6 247 115 32.2 0.89 27 2.23 10.6 258 119 34.9 0.93 27 2.28 10.8 266 122 36.0 0.97 26 2.30 10.9 268 124 63 31.7 0.83 25 2.21 10.5 255 118 34.4 0.86 25 2.27 10.7 263 121 35.4 0.90 24 2.28 10.8 266 122 75 33.8 0.81 26 2.30 10.9 272 130 36.6 0.84 26 2.36 11.1 281 134 37.7 0.88 25 2.38 11.2 284 135 67 33.9 0.67 22 2.28 10.8 270 128 36.8 0.70 21 2.34 11.0 278 132 37.9 0.73 21 2.36 11.1 281 134 36.0 0.65 22 2.38 11.2 284 138 39.0 0.68 22 2.44 11.5 293 142 40.2 0.71 21 2.46 11.6 296 144 71 36.3 0.50 17 2.36 11.1 281 137 39.3 0.52 17 2.42 11.4 290 141 40.5 0.55 16 2.44 11.5 293 142 30.9 0.95 28 2.32 11.1 273 116 33.4 0.98 28 2.38 11.4 281 120 34.4 1.00 26 2.40 11.5 284 121 59 30.3 0.91 26 2.30 11.0 270 115 32.9 0.94 26 2.36 11.3 278 118 33.8 1.00 25 2.38 11.4 281 120 31.5 0.92 28 2.37 11.3 293 123 34.1 0.95 27 2.43 11.6 302 127 35.1 1.00 26 2.45 11.7 305 128 32.9 0.83 26 2.45 11.7 310 135 35.7 0.86 26 2.51 11.9 319 139 36.8 0.90 25 2.53 12.0 322 140 35.1 0.67 23 2.53 12.0 323 143 38.1 0.70 22 2.60 12.3 333 148 39.2 0.73 21 2.62 12.4 336 149 30.1 0.98 28 2.44 11.8 310 122 32.6 1.00 27 2.50 12.0 320 126 33.6 1.00 25 2.53 12.1 323 127 30.7 0.95 28 2.50 12.0 334 130 33.3 0.98 27 2.56 12.3 344 134 34.2 1.00 25 2.58 12.4 348 135 32.1 0.85 26 2.58 12.4 353 141 34.8 0.89 26 2.65 12.7 364 146 35.9 0.93 25 2.67 12.8 367 147 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 31.0 33.1 35.4 29.6 30.2 32.3 0.85 0.69 0.52 0.93 0.88 0.71 22 17 26 25 22 25 2.35 2.43 2.51 2.42 2.48 2.56 11.2 11.6 11.9 11.7 11.9 12.3 290 307 320 307 331 349 122 133 142 121 128 140 33.6 35.9 38.4 32.1 32.8 35.0 0.88 0.72 0.54 0.97 0.91 0.74 21 17 26 25 22 25 2.41 2.49 2.57 2.48 2.54 2.62 11.5 11.8 12.2 12.0 12.2 12.6 299 316 330 317 341 360 126 137 146 124 132 144 34.6 37.0 39.5 33.0 33.7 36.1 0.92 0.75 0.56 1.00 0.95 0.78 25 24 21 24 21 16 2.43 2.51 2.60 2.50 2.56 2.65 11.6 11.9 12.3 12.0 12.3 12.7 302 319 333 320 344 364 127 139 148 126 134 146 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 MODEL: *SXC160481B* / CA*F4860*6** + TXV / MBVC2000**-1** 34.3 0.69 23 2.67 12.8 368 151 37.2 0.72 22 2.74 13.1 379 155 38.3 0.75 21 2.76 13.2 383 157 71 34.5 0.53 18 2.64 12.7 364 149 37.4 0.55 17 2.71 13.0 375 154 38.5 0.58 17 2.74 13.1 379 155 EXPANDED PERFORMANCE DATA 28.6 1.00 27 2.55 12.4 349 128 31.0 1.00 26 2.61 12.7 360 132 31.9 1.00 24 2.63 12.8 364 133 59 28.1 0.97 26 2.52 12.3 346 126 30.5 1.00 25 2.59 12.6 356 130 31.4 1.00 23 2.61 12.7 360 132 29.2 0.98 27 2.60 12.7 376 136 31.6 1.00 26 2.67 13.0 387 140 32.5 1.00 24 2.69 13.1 391 141 63 28.7 0.91 25 2.58 12.6 372 134 31.1 0.94 25 2.65 12.9 384 139 32.1 1.00 24 2.67 13.0 387 140 30.5 0.89 26 2.69 13.0 397 148 33.1 0.92 25 2.76 13.4 409 153 34.1 0.96 24 2.78 13.5 413 154 67 30.7 0.74 22 2.67 12.9 393 147 33.3 0.77 21 2.74 13.3 405 151 34.2 0.81 20 2.76 13.4 409 153 105 26.5 1.00 25 2.64 13.1 386 132 28.7 1.00 24 2.70 13.4 398 136 29.6 1.00 22 2.73 13.5 402 137 59 26.0 0.98 24 2.61 12.9 382 131 28.2 1.00 24 2.68 13.3 394 135 29.1 1.00 22 2.70 13.4 398 136 27.0 0.99 26 2.69 13.3 415 140 29.3 1.00 24 2.77 13.7 428 145 30.1 1.00 22 2.79 13.8 432 146 63 26.6 0.92 23 2.67 13.2 411 139 28.8 0.95 23 2.74 13.6 424 143 29.7 1.00 22 2.77 13.7 428 145 28.3 0.89 24 2.79 13.7 438 153 30.6 0.93 24 2.86 14.1 452 158 31.6 0.97 23 2.88 14.2 456 160 67 28.4 0.75 20 2.76 13.6 434 152 30.8 0.77 20 2.83 14.0 447 157 31.7 0.81 19 2.86 14.1 452 158 30.2 0.72 21 2.88 14.2 457 163 32.7 0.75 21 2.96 14.6 471 168 33.7 0.79 20 2.98 14.7 476 170 71 30.4 0.56 16 2.86 14.1 453 162 32.9 0.58 16 2.93 14.4 467 167 33.9 0.61 15 2.96 14.6 471 168 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 32.6 0.72 22 2.78 13.5 414 158 35.3 0.75 22 2.85 13.8 427 163 36.4 0.78 21 2.88 13.9 431 164 71 32.8 0.55 17 2.76 13.4 410 156 35.5 0.57 17 2.83 13.7 422 161 36.6 0.60 16 2.85 13.8 427 163 115 COOLING OPERATION PERFORMANCE DATA *SXC160481B*-LOW STAGE 21 22 1575 1400 1225 1575 1400 1225 Airflow 59 37.4 0.69 19 2.57 9.9 226 118 40.6 0.71 19 2.59 10.0 228 119 41.8 0.75 18 2.61 10.1 231 120 38.1 0.78 22 2.57 9.9 226 118 41.3 0.81 22 2.59 10.0 228 119 42.5 0.85 21 2.61 10.1 231 120 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 39.2 0.70 21 2.63 10.1 243 122 42.5 0.73 20 2.65 10.2 246 123 43.8 0.76 19 2.67 10.3 248 124 63 38.8 0.57 17 2.63 10.1 243 122 42.0 0.60 16 2.65 10.2 246 123 43.3 0.62 16 2.67 10.3 248 124 42.4 0.53 17 2.72 10.5 247 133 46.0 0.55 17 2.74 10.6 249 134 47.4 0.58 16 2.76 10.7 252 136 67 42.5 0.40 13 2.72 10.5 247 133 46.1 0.41 12 2.74 10.6 249 134 47.5 0.43 12 2.76 10.7 252 136 45.5 0.34 12 2.81 10.9 252 142 49.3 0.35 11 2.83 11.0 255 143 50.8 0.37 11 2.86 11.1 257 144 71 37.2 0.81 23 2.78 10.7 248 122 40.3 0.84 22 2.80 10.8 251 123 41.5 0.88 21 2.83 10.9 253 124 59 36.6 0.71 20 2.78 10.7 248 122 39.6 0.74 19 2.80 10.8 251 123 40.8 0.78 18 2.83 10.9 253 124 38.3 0.72 21 2.84 11.0 267 125 41.5 0.75 20 2.87 11.1 270 127 42.7 0.79 20 2.89 11.2 272 128 63 37.9 0.60 17 2.84 11.0 267 125 41.1 0.62 17 2.87 11.1 270 127 42.3 0.65 16 2.89 11.2 272 128 75 41.5 0.55 17 2.94 11.4 271 137 44.9 0.57 17 2.97 11.5 274 138 46.3 0.60 16 2.99 11.6 276 140 67 41.5 0.41 13 2.94 11.4 271 137 45.0 0.43 13 2.97 11.5 274 138 46.3 0.45 12 2.99 11.6 276 140 44.5 0.35 12 3.04 11.8 277 146 48.2 0.37 12 3.07 11.9 280 147 49.6 0.38 11 3.10 12.0 282 149 71 36.3 0.83 23 2.97 11.7 291 126 39.3 0.86 22 2.99 11.8 294 127 40.5 0.90 21 3.02 11.9 297 128 59 35.7 0.73 20 2.97 11.7 291 126 38.7 0.76 19 2.99 11.8 294 127 39.8 0.80 18 3.02 11.9 297 128 37.4 0.74 21 3.03 12.0 313 130 40.5 0.77 21 3.06 12.1 316 131 41.7 0.81 20 3.09 12.2 319 132 40.5 0.56 17 3.14 12.4 317 142 43.8 0.58 17 3.17 12.5 320 143 45.2 0.61 16 3.19 12.6 323 144 43.4 0.36 12 3.25 12.8 324 151 47.1 0.38 12 3.28 13.0 327 152 48.5 0.39 11 3.31 13.1 331 154 35.4 0.86 23 3.13 12.5 331 129 38.4 0.89 22 3.16 12.6 335 130 39.5 0.93 22 3.19 12.7 338 132 36.5 0.77 21 3.20 12.8 356 133 39.5 0.80 21 3.23 12.9 360 134 40.7 0.83 20 3.26 13.0 363 136 39.5 0.58 17 3.31 13.2 361 145 42.8 0.60 17 3.34 13.4 365 147 44.1 0.63 16 3.37 13.5 368 148 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 37.0 40.5 34.8 36.1 39.6 0.61 0.42 0.75 0.63 0.44 17 13 20 17 13 3.03 3.14 3.13 3.20 3.31 12.0 12.4 12.5 12.8 13.2 313 317 331 356 361 130 142 129 133 145 40.1 43.9 37.7 39.1 42.9 0.63 0.44 0.78 0.65 0.45 17 13 19 17 13 3.06 3.17 3.16 3.23 3.34 12.1 12.5 12.6 12.9 13.4 316 320 335 360 365 131 143 130 134 147 41.3 45.2 38.9 40.3 44.1 0.66 0.46 0.82 0.69 0.47 16 12 19 16 12 3.09 3.19 3.19 3.26 3.37 12.2 12.6 12.7 13.0 13.5 319 323 338 363 368 132 144 132 136 148 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 42.4 0.37 12 3.43 13.7 369 155 45.9 0.39 12 3.46 13.9 373 156 47.3 0.41 11 3.49 14.0 377 158 71 33.7 0.89 22 3.27 14.6 373 132 36.5 0.92 22 3.30 14.7 376 133 37.6 0.97 21 3.33 14.9 380 134 59 33.1 0.78 19 3.27 14.6 373 132 35.9 0.81 19 3.30 14.7 376 133 36.9 0.85 18 3.33 14.9 380 134 34.6 0.80 21 3.35 15.0 401 136 37.5 0.83 20 3.38 15.1 405 137 38.7 0.87 20 3.41 15.2 409 139 63 34.3 0.65 17 3.35 15.0 401 136 37.2 0.68 17 3.38 15.1 405 137 38.3 0.71 16 3.41 15.2 409 139 37.5 0.60 17 3.46 15.5 406 148 40.6 0.63 17 3.49 15.6 410 150 41.9 0.66 16 3.52 15.8 415 151 67 37.6 0.45 13 3.46 15.5 406 148 40.7 0.47 13 3.49 15.6 410 150 41.9 0.49 12 3.52 15.8 415 151 105 31.2 0.90 21 3.39 15.4 431 135 33.8 0.93 21 3.42 15.6 435 136 34.8 0.98 20 3.45 15.7 439 138 59 30.7 0.79 18 3.39 15.4 431 135 33.2 0.82 18 3.42 15.6 435 136 34.2 0.86 17 3.45 15.7 439 138 32.1 0.80 19 3.47 15.8 463 139 34.8 0.83 19 3.50 15.9 468 141 35.8 0.87 18 3.53 16.1 472 142 63 31.8 0.66 16 3.47 15.8 463 139 34.4 0.68 15 3.50 15.9 468 141 35.5 0.72 15 3.53 16.1 472 142 34.7 0.61 16 3.59 16.3 469 152 37.6 0.63 16 3.62 16.5 474 153 38.8 0.66 15 3.66 16.7 479 155 67 34.8 0.46 12 3.59 16.3 469 152 37.7 0.47 12 3.62 16.5 474 153 38.8 0.50 11 3.66 16.7 479 155 37.3 0.39 11 3.72 17.0 480 162 40.4 0.41 11 3.75 17.1 485 163 41.6 0.43 10 3.79 17.3 490 165 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 40.3 0.39 12 3.58 16.1 415 158 43.6 0.40 12 3.62 16.2 419 159 44.9 0.42 11 3.65 16.4 424 161 71 - 115 COOLING OPERATION MODEL: *SXC160601A* / CA*F4961*6** + TXV / MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA PERFORMANCE DATA *SXC160601A*-LOW STAGE 1575 1400 1225 1575 1400 1225 Airflow 67 42.3 0.65 21 2.72 10.5 247 133 45.8 0.68 20 2.74 10.6 249 134 47.2 0.71 20 2.76 10.7 252 136 42.1 0.78 25 2.72 10.5 247 133 45.6 0.81 24 2.74 10.6 249 134 47.0 0.85 23 2.76 10.7 252 136 MBh 39.4 40.2 S/T 0.90 0.87 Delta T 27 26 KW 2.57 2.63 AMPS 9.9 10.1 HI PR 226 243 LO PR 118 122 MBh 42.7 43.6 S/T 0.93 0.90 Delta T 26 26 KW 2.59 2.65 AMPS 10.0 10.2 HI PR 228 246 LO PR 119 123 MBh 44.0 44.9 S/T 0.98 0.94 Delta T 25.12 25 KW 2.61 2.67 AMPS 10.1 10.3 HI PR 231 248 LO PR 120 124 59 38.8 0.86 25 2.57 9.9 226 118 42.0 0.89 25 2.59 10.0 228 119 43.3 0.93 24 2.61 10.1 231 120 63 39.6 0.80 24 2.63 10.1 243 122 42.9 0.83 24 2.65 10.2 246 123 44.2 0.87 23 2.67 10.3 248 124 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 44.9 0.64 21 2.81 10.9 252 142 48.7 0.66 21 2.83 11.0 255 143 50.1 0.69 20 2.86 11.1 257 144 71 45.2 0.49 17 2.81 10.9 252 142 49.0 0.51 16 2.83 11.0 255 143 50.5 0.53 16 2.86 11.1 257 144 38.5 0.93 27 2.78 10.7 248 122 41.7 0.97 26 2.80 10.8 251 123 43.0 1.00 25 2.83 10.9 253 124 59 37.9 0.89 25 2.78 10.7 248 122 41.0 0.92 25 2.80 10.8 251 123 42.2 0.97 24 2.83 10.9 253 124 39.3 0.90 26 2.84 11.0 267 125 42.5 0.93 26 2.87 11.1 270 127 43.8 0.98 25 2.89 11.2 272 128 63 38.7 0.83 24 2.84 11.0 267 125 41.9 0.86 24 2.87 11.1 270 127 43.2 0.91 23 2.89 11.2 272 128 75 41.1 0.81 25 2.94 11.4 271 137 44.6 0.84 25 2.97 11.5 274 138 45.9 0.88 24 2.99 11.6 276 140 67 41.3 0.68 21 2.94 11.4 271 137 44.8 0.70 21 2.97 11.5 274 138 46.1 0.74 20 2.99 11.6 276 140 43.9 0.66 22 3.04 11.8 277 146 47.5 0.68 21 3.07 11.9 280 147 49.0 0.72 20 3.10 12.0 282 149 71 44.2 0.51 17 3.04 11.8 277 146 47.9 0.53 17 3.07 11.9 280 147 49.3 0.55 16 3.10 12.0 282 149 37.6 0.96 27 2.97 11.7 291 126 40.7 0.99 27 2.99 11.8 294 127 42.0 1.00 24 3.02 11.9 297 128 59 37.0 0.91 25 2.97 11.7 291 126 40.0 0.95 25 2.99 11.8 294 127 41.2 1.00 24 3.02 11.9 297 128 38.3 0.92 27 3.03 12.0 313 130 41.5 0.96 26 3.06 12.1 316 131 42.8 1.00 25 3.09 12.2 319 132 40.1 0.83 25 3.14 12.4 317 142 43.5 0.86 25 3.17 12.5 320 143 44.8 0.90 24 3.19 12.6 323 144 42.8 0.68 22 3.25 12.8 324 151 46.4 0.70 21 3.28 13.0 327 152 47.8 0.73 20 3.31 13.1 331 154 36.7 0.99 27 3.13 12.5 331 129 39.7 1.00 26 3.16 12.6 335 130 40.9 1.00 24 3.19 12.7 338 132 37.4 0.95 27 3.20 12.8 356 133 40.5 0.99 26 3.23 12.9 360 134 41.7 1.00 24 3.26 13.0 363 136 39.2 0.86 25 3.31 13.2 361 145 42.4 0.89 25 3.34 13.4 365 147 43.7 0.93 24 3.37 13.5 368 148 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 37.8 40.3 43.1 36.1 36.8 39.4 0.85 0.70 0.52 0.94 0.88 0.72 24 21 17 25 24 21 3.03 3.14 3.25 3.13 3.20 3.31 12.0 12.4 12.8 12.5 12.8 13.2 313 317 324 331 356 361 130 142 151 129 133 145 40.9 43.7 46.7 39.1 39.9 42.6 0.89 0.72 0.54 0.98 0.92 0.74 24 21 17 25 24 21 3.06 3.17 3.28 3.16 3.23 3.34 12.1 12.5 13.0 12.6 12.9 13.4 316 320 327 335 360 365 131 143 152 130 134 147 42.1 45.0 48.1 40.2 41.1 43.9 0.93 0.76 0.57 1.00 0.96 0.78 23 20 16 23 23 20 3.09 3.19 3.31 3.19 3.26 3.37 12.2 12.6 13.1 12.7 13.0 13.5 319 323 331 338 363 368 132 144 154 132 136 148 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 41.8 0.70 22 3.43 13.7 369 155 45.3 0.72 21 3.46 13.9 373 156 46.6 0.76 21 3.49 14.0 377 158 71 42.1 0.54 17 3.43 13.7 369 155 45.6 0.56 17 3.46 13.9 373 156 47.0 0.58 16 3.49 14.0 377 158 34.8 1.00 26 3.27 14.6 373 132 37.8 1.00 25 3.30 14.7 376 133 38.9 1.00 23 3.33 14.9 380 134 59 34.3 0.98 25 3.27 14.6 373 132 37.1 1.00 24 3.30 14.7 376 133 38.2 1.00 22 3.33 14.9 380 134 35.5 0.99 26 3.35 15.0 401 136 38.5 1.00 25 3.38 15.1 405 137 39.6 1.00 23 3.41 15.2 409 139 63 35.0 0.92 24 3.35 15.0 401 136 37.9 0.95 24 3.38 15.1 405 137 39.1 1.00 23 3.41 15.2 409 139 37.2 0.89 25 3.46 15.5 406 148 40.3 0.92 24 3.49 15.6 410 150 41.5 0.97 23 3.52 15.8 415 151 67 37.4 0.75 21 3.46 15.5 406 148 40.5 0.77 21 3.49 15.6 410 150 41.7 0.81 20 3.52 15.8 415 151 105 32.3 1.00 24 3.39 15.4 431 135 35.0 1.00 23 3.42 15.6 435 136 36.0 1.00 21 3.45 15.7 439 138 59 31.7 0.98 23 3.39 15.4 431 135 34.4 1.00 23 3.42 15.6 435 136 35.4 1.00 21 3.45 15.7 439 138 32.9 1.00 25 3.47 15.8 463 139 35.7 1.00 23 3.50 15.9 468 141 36.7 1.00 21 3.53 16.1 472 142 63 32.4 0.92 22 3.47 15.8 463 139 35.1 0.96 22 3.50 15.9 468 141 36.2 1.00 21 3.53 16.1 472 142 34.5 0.90 23 3.59 16.3 469 152 37.3 0.93 23 3.62 16.5 474 153 38.5 0.98 22 3.66 16.7 479 155 67 34.6 0.75 20 3.59 16.3 469 152 37.5 0.78 19 3.62 16.5 474 153 38.7 0.82 18 3.66 16.7 479 155 36.8 0.73 20 3.72 17.0 480 162 39.8 0.76 20 3.75 17.1 485 163 41.0 0.79 19 3.79 17.3 490 165 71 37.0 0.56 16 3.72 17.0 480 162 40.1 0.58 15 3.75 17.1 485 163 41.3 0.61 15 3.79 17.3 490 165 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 39.7 0.72 22 3.58 16.1 415 158 43.0 0.75 21 3.62 16.2 419 159 44.3 0.79 20 3.65 16.4 424 161 71 40.0 0.56 17 3.58 16.1 415 158 43.3 0.58 16 3.62 16.2 419 159 44.6 0.61 16 3.65 16.4 424 161 115 COOLING OPERATION MODEL: *SXC160601A* / CA*F4961*6** + TXV / MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA PERFORMANCE DATA *SXC160601A*-LOW STAGE 23 24 2025 1800 1575 2025 1800 1575 Airflow 59 50.1 0.68 20 3.45 13.6 222 100 54.2 0.71 20 3.54 13.9 229 103 55.9 0.74 19 3.57 14.1 231 104 50.9 0.78 23 3.48 13.7 224 101 55.1 0.81 23 3.57 14.1 231 104 56.8 0.84 22 3.60 14.2 233 105 MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR 52.4 0.69 21 3.56 14.0 241 108 56.8 0.72 21 3.65 14.4 248 111 58.5 0.76 20 3.68 14.6 251 112 63 51.9 0.57 17 3.53 13.9 239 106 56.2 0.59 17 3.62 14.3 246 110 57.9 0.62 16 3.65 14.4 248 111 56.7 0.53 17 3.68 14.5 254 117 61.5 0.55 17 3.78 14.9 262 121 63.3 0.57 16 3.81 15.0 265 122 67 56.8 0.40 13 3.65 14.4 252 116 61.6 0.41 13 3.74 14.8 260 120 63.4 0.43 12 3.77 14.9 262 121 60.9 0.34 12 3.80 15.0 265 125 66.0 0.35 12 3.90 15.5 274 129 67.9 0.37 11 3.94 15.6 276 130 71 49.7 0.81 23 3.77 14.8 251 107 53.9 0.84 23 3.87 15.3 259 110 55.5 0.88 22 3.90 15.4 262 111 59 48.9 0.71 20 3.73 14.7 249 106 53.0 0.73 20 3.83 15.1 256 109 54.6 0.77 19 3.86 15.2 259 110 51.2 0.72 22 3.85 15.2 270 114 55.5 0.75 21 3.95 15.6 279 117 57.1 0.78 20 3.99 15.8 282 118 63 50.7 0.59 17 3.82 15.0 268 112 54.9 0.61 17 3.92 15.5 276 116 56.5 0.64 17 3.95 15.6 279 117 75 55.4 0.55 18 3.98 15.7 286 124 60.0 0.57 17 4.09 16.2 294 128 61.8 0.59 17 4.12 16.3 297 129 67 55.5 0.41 13 3.95 15.6 283 123 60.1 0.43 13 4.05 16.0 291 127 62.0 0.45 13 4.09 16.2 294 128 59.5 0.35 12 4.12 16.3 298 132 64.4 0.36 12 4.23 16.8 307 136 66.4 0.38 11 4.27 16.9 310 138 71 48.5 0.83 23 4.02 16.1 286 111 52.6 0.86 23 4.12 16.6 295 114 54.2 0.90 22 4.16 16.8 298 116 59 47.7 0.73 20 3.98 16.0 283 110 51.7 0.75 20 4.09 16.5 292 113 53.3 0.79 19 4.12 16.6 295 114 50.0 0.74 22 4.11 16.5 308 118 54.1 0.77 21 4.22 17.0 317 122 55.8 0.80 20 4.26 17.2 320 123 54.1 0.56 18 4.25 17.1 325 129 58.6 0.58 17 4.36 17.6 335 133 60.4 0.61 17 4.40 17.8 338 134 58.1 0.36 12 4.40 17.8 339 137 62.9 0.37 12 4.52 18.3 349 142 64.8 0.39 12 4.56 18.5 353 143 47.3 0.85 24 4.24 17.3 326 117 51.3 0.88 23 4.35 17.8 336 120 52.8 0.93 22 4.39 18.0 339 121 48.8 0.76 22 4.34 17.7 350 124 52.8 0.79 21 4.45 18.2 361 128 54.4 0.83 20 4.49 18.4 365 129 52.8 0.58 18 4.49 18.3 370 135 57.2 0.60 17 4.61 18.9 381 140 58.9 0.63 17 4.65 19.0 385 141 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 49.5 54.2 46.6 48.3 52.9 0.61 0.42 0.75 0.63 0.43 18 13 20 18 13 4.07 4.21 4.20 4.30 4.45 16.4 16.9 17.1 17.5 18.1 304 321 322 347 366 117 128 115 123 134 53.6 58.7 50.4 52.3 57.3 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 4.18 4.33 4.31 4.41 4.57 16.9 17.4 17.6 18.1 18.7 314 331 332 357 377 120 132 119 127 138 55.2 60.5 52.0 53.9 59.0 0.66 0.46 0.82 0.68 0.47 17 13 19 17 13 4.22 4.36 4.35 4.45 4.61 17.0 17.6 17.8 18.2 18.9 317 335 336 361 381 122 133 120 128 140 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 56.6 0.37 12 4.64 19.0 386 144 61.4 0.38 12 4.77 19.6 398 149 63.2 0.40 12 4.81 19.8 402 150 71 45.0 0.88 23 4.43 18.4 366 122 48.7 0.92 23 4.55 19.0 378 126 50.2 0.96 22 4.59 19.1 381 127 59 44.2 0.78 20 4.39 18.2 363 121 47.9 0.81 20 4.51 18.8 374 125 49.4 0.85 19 4.55 19.0 377 126 46.3 0.79 21 4.53 18.9 394 130 50.2 0.82 21 4.65 19.4 406 134 51.7 0.86 20 4.70 19.6 410 135 63 45.8 0.65 17 4.49 18.7 390 129 49.7 0.67 17 4.61 19.2 402 133 51.2 0.71 16 4.65 19.4 406 134 50.1 0.60 18 4.69 19.5 416 142 54.3 0.62 17 4.82 20.1 429 146 55.9 0.65 17 4.86 20.3 433 148 67 50.2 0.45 13 4.65 19.3 412 140 54.4 0.47 13 4.77 19.9 425 145 56.1 0.49 12 4.82 20.1 429 146 105 41.7 0.89 22 4.59 19.5 405 126 45.1 0.93 21 4.71 20.1 417 130 46.5 0.97 20 4.76 20.3 421 132 59 41.0 0.78 19 4.55 19.4 401 125 44.4 0.81 18 4.67 19.9 413 129 45.7 0.85 18 4.71 20.1 417 130 42.9 0.80 20 4.70 20.0 435 134 46.5 0.83 20 4.83 20.6 449 139 47.9 0.87 19 4.87 20.8 453 140 63 42.5 0.66 16 4.66 19.8 431 133 46.0 0.68 16 4.78 20.4 444 137 47.4 0.71 15 4.83 20.6 449 139 46.4 0.60 16 4.86 20.7 460 147 50.3 0.63 16 5.00 21.3 474 151 51.8 0.66 15 5.04 21.5 479 153 67 46.5 0.45 12 4.82 20.5 455 145 50.4 0.47 12 4.95 21.1 469 150 51.9 0.49 12 4.99 21.3 474 151 49.8 0.39 11 5.03 21.5 480 156 54.0 0.40 11 5.17 22.2 494 161 55.6 0.42 11 5.22 22.4 499 163 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 53.8 0.39 12 4.85 20.3 434 151 58.3 0.40 12 4.99 20.9 447 156 60.0 0.42 11 5.03 21.1 452 157 71 - 115 COOLING OPERATION MODEL: *SXC160601 B*/CA*F496*6** +TXV/MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA PERFORMANCE DATA *SXC160601B*-LOW STAGE EXPANDED PERFORMANCE DATA 2025 1800 1575 2025 1800 1575 Airflow 59 51.8 0.85 26 3.51 13.8 226 102 56.1 0.88 25 3.60 14.2 233 105 57.8 0.93 24 3.63 14.3 236 106 52.7 0.89 27 3.54 13.9 228 103 57.1 0.93 27 3.63 14.3 236 106 58.8 0.97 25.94 3.66 14.5 238 107 MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR 53.7 0.86 27 3.62 14.3 246 110 58.2 0.89 27 3.72 14.7 253 113 60.0 0.94 26 3.75 14.8 256 114 63 52.9 0.80 25 3.59 14.2 243 109 57.4 0.83 24 3.68 14.6 251 112 59.1 0.87 23 3.72 14.7 253 113 56.3 0.78 26 3.74 14.8 260 120 61.0 0.81 25 3.84 15.2 268 123 62.8 0.85 24 3.87 15.3 270 125 67 56.6 0.65 21 3.71 14.6 257 119 61.3 0.67 21 3.81 15.1 265 122 63.1 0.71 20 3.84 15.2 268 123 60.0 0.63 22 3.87 15.3 271 128 65.0 0.65 22 3.97 15.8 279 131 67.0 0.69 21 4.01 15.9 282 133 71 60.5 0.49 17 3.84 15.2 268 126 65.5 0.50 17 3.94 15.6 276 130 67.5 0.53 16 3.97 15.8 279 131 51.5 0.93 28 3.83 15.1 256 109 55.8 0.96 27 3.93 15.5 264 112 57.5 1.00 26 3.97 15.7 267 113 59 50.6 0.88 26 3.80 15.0 254 108 54.8 0.92 26 3.90 15.4 262 111 56.5 0.96 25 3.93 15.5 264 112 52.5 0.89 27 3.92 15.5 276 116 56.9 0.93 27 4.02 15.9 284 119 58.6 0.97 26 4.06 16.1 287 121 63 51.7 0.83 25 3.88 15.3 273 115 56.0 0.86 25 3.99 15.8 282 118 57.7 0.90 24 4.02 15.9 284 119 75 55.0 0.81 26 4.05 16.0 291 127 59.6 0.84 25 4.16 16.5 300 130 61.3 0.88 24 4.20 16.6 303 132 67 55.2 0.67 22 4.02 15.9 288 125 59.9 0.70 21 4.12 16.3 297 129 61.6 0.73 21 4.16 16.5 300 130 58.6 0.65 22 4.19 16.6 304 135 63.5 0.68 22 4.30 17.1 313 139 65.4 0.71 21 4.34 17.3 316 140 71 59.1 0.50 17 4.16 16.5 301 133 64.0 0.52 17 4.27 16.9 310 138 65.9 0.55 16 4.30 17.1 313 139 50.3 0.95 28 4.09 16.4 292 113 54.5 0.98 27 4.20 16.9 301 117 56.1 1.00 25 4.23 17.1 304 118 59 49.4 0.91 26 4.05 16.3 289 112 53.5 0.94 26 4.16 16.8 298 116 55.1 1.00 25 4.20 16.9 301 117 51.2 0.92 27 4.18 16.9 314 120 55.5 0.95 27 4.29 17.3 323 124 57.2 1.00 26 4.33 17.5 327 125 53.7 0.83 26 4.33 17.4 331 132 58.1 0.86 25 4.44 17.9 342 136 59.9 0.90 24 4.48 18.1 345 137 57.2 0.67 22 4.48 18.1 346 140 62.0 0.70 22 4.60 18.6 356 144 63.9 0.73 21 4.64 18.8 360 146 49.0 0.98 28 4.31 17.6 332 119 53.1 1.00 27 4.43 18.1 342 123 54.7 1.00 25 4.47 18.3 346 124 50.0 0.95 28 4.41 18.1 357 127 54.2 0.98 27 4.53 18.6 368 130 55.8 1.00 25 4.57 18.8 372 132 52.3 0.85 26 4.57 18.7 377 138 56.7 0.89 26 4.69 19.2 389 142 58.4 0.93 25 4.73 19.4 393 144 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 50.5 53.9 57.6 48.2 49.2 52.6 0.85 0.69 0.52 0.93 0.88 0.71 25 22 17 26 25 22 4.15 4.29 4.44 4.28 4.38 4.53 16.7 17.3 17.9 17.4 17.9 18.5 311 328 342 329 354 374 119 130 139 118 125 137 57.0 54.7 58.4 62.5 52.2 53.4 0.88 0.72 0.54 0.97 0.91 0.74 22 25 21 17 26 25 4.26 4.40 4.56 4.39 4.49 4.65 19.0 17.2 17.8 18.5 18.0 18.4 320 338 353 339 365 385 123 134 143 121 129 141 56.3 60.2 64.3 53.8 55.0 58.7 0.92 0.75 0.56 1.00 0.95 0.78 24 21 16 24 24 21 4.29 4.44 4.60 4.43 4.53 4.69 17.3 17.9 18.6 18.1 18.6 19.2 323 342 356 342 368 389 124 136 144 123 130 142 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 55.8 0.69 23 4.73 19.4 394 147 60.5 0.72 22 4.86 20.0 406 152 62.3 0.75 21 4.90 20.2 410 153 71 56.2 0.53 18 4.69 19.2 390 146 60.9 0.55 17 4.81 19.8 402 150 62.8 0.58 17 4.86 20.0 406 152 46.6 1.00 27 4.51 18.8 374 125 50.5 1.00 26 4.63 19.3 385 129 52.0 1.00 24 4.67 19.5 389 130 59 45.8 0.97 26 4.47 18.6 370 123 49.6 1.00 25 4.59 19.1 381 127 51.1 1.00 23 4.63 19.3 385 129 47.5 0.98 27 4.61 19.2 402 133 51.4 1.00 26 4.74 19.8 414 137 53.0 1.00 24 4.78 20.0 419 138 63 46.8 0.91 25 4.57 19.1 398 131 50.7 0.94 24 4.70 19.6 410 135 52.2 1.00 24 4.74 19.8 414 137 49.7 0.89 26 4.77 19.9 425 145 53.9 0.92 25 4.90 20.5 438 149 55.5 0.96 24 4.95 20.7 442 151 67 50.0 0.74 22 4.73 19.7 420 143 54.2 0.77 21 4.86 20.3 433 148 55.8 0.81 20 4.90 20.5 438 149 105 43.1 1.00 25 4.67 19.9 413 129 46.7 1.00 24 4.80 20.5 426 133 48.2 1.00 22 4.84 20.7 430 134 59 42.4 0.98 24 4.63 19.7 409 128 45.9 1.00 23 4.76 20.3 421 132 47.3 1.00 21 4.80 20.5 426 133 44.0 0.99 25 4.78 20.4 444 137 47.7 1.00 24 4.91 21.0 458 141 49.1 1.00 22 4.96 21.2 463 143 63 43.3 0.92 23 4.74 20.2 440 136 46.9 0.95 23 4.87 20.8 453 140 48.4 1.00 22 4.91 21.0 458 141 46.1 0.89 24 4.95 21.1 469 150 49.9 0.93 24 5.09 21.7 484 154 51.4 0.97 23 5.13 22.0 488 156 67 46.3 0.75 20 4.91 20.9 464 148 50.2 0.77 20 5.04 21.5 479 153 51.7 0.81 19 5.09 21.7 484 154 49.1 0.72 21 5.13 21.9 489 159 53.2 0.75 20 5.27 22.6 504 164 54.8 0.79 20 5.31 22.8 509 166 71 49.5 0.56 16 5.08 21.7 484 158 53.6 0.58 16 5.22 22.4 499 163 55.2 0.61 15 5.27 22.6 504 164 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 53.1 0.72 22 4.94 20.7 443 154 57.5 0.75 22 5.08 21.3 457 159 59.2 0.78 21 5.12 21.5 461 161 71 53.4 0.55 17 4.90 20.5 438 153 57.9 0.57 17 5.03 21.1 452 157 59.6 0.60 16 5.08 21.3 457 159 115 COOLING OPERATION MODEL: *SXC160601 B*/CA*F496*6** +TXV/MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. PERFORMANCE DATA *SXC160601B*-LOW STAGE 25 26 900 800 700 900 800 700 Airflow 59 21.1 0.70 19 1.48 5.8 232 119 22.8 0.72 19 1.49 5.9 234 120 23.5 0.76 18 1.50 5.9 237 122 21.4 0.79 22 1.48 5.8 232 119 23.2 0.82 22 1.49 5.9 234 120 23.9 0.86 21 1.50 5.9 237 122 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 22.1 0.71 21 1.51 5.9 249 123 23.9 0.73 20 1.52 6.0 252 124 24.6 0.77 19 1.53 6.0 255 125 63 21.8 0.58 17 1.51 5.9 249 123 23.7 0.60 16 1.52 6.0 252 124 24.4 0.63 16 1.53 6.0 255 125 23.9 0.54 17 1.56 6.1 253 134 25.9 0.56 17 1.57 6.2 256 136 26.7 0.58 16 1.58 6.2 258 137 67 23.9 0.40 13 1.56 6.1 253 134 25.9 0.42 12 1.57 6.2 256 136 26.7 0.44 12 1.58 6.2 258 137 25.6 0.34 12 1.61 6.3 259 143 27.8 0.36 11 1.62 6.4 261 144 28.6 0.37 11 1.63 6.5 264 146 71 20.9 0.82 23 1.59 6.3 262 123 22.7 0.85 22 1.61 6.3 265 124 23.4 0.89 21 1.62 6.4 268 125 59 20.6 0.72 20 1.59 6.3 262 123 22.3 0.75 19 1.61 6.3 265 124 23.0 0.78 18 1.62 6.4 268 125 21.6 0.73 21 1.63 6.4 282 127 23.4 0.76 20 1.64 6.5 285 128 24.1 0.80 20 1.65 6.5 288 129 63 21.3 0.60 17 1.63 6.4 282 127 23.1 0.63 17 1.64 6.5 285 128 23.8 0.66 16 1.65 6.5 288 129 75 23.3 0.56 17 1.68 6.6 286 138 25.3 0.58 17 1.69 6.7 289 140 26.0 0.60 16 1.71 6.7 292 141 67 23.4 0.42 13 1.68 6.6 286 138 25.3 0.43 13 1.69 6.7 289 140 26.1 0.45 12 1.71 6.7 292 141 25.0 0.36 12 1.74 6.8 292 147 27.1 0.37 12 1.75 6.9 295 149 27.9 0.39 11 1.77 7.0 298 150 71 20.4 0.84 23 1.69 6.8 298 127 22.1 0.87 22 1.71 6.8 301 128 22.8 0.91 21 1.72 6.9 304 129 59 20.1 0.74 20 1.69 6.8 298 127 21.8 0.77 19 1.71 6.8 301 128 22.4 0.80 18 1.72 6.9 304 129 21.0 0.75 21 1.73 6.9 321 131 22.8 0.78 20 1.75 7.0 324 132 23.5 0.82 20 1.76 7.1 327 134 22.8 0.57 17 1.79 7.2 325 143 24.7 0.59 17 1.80 7.2 329 144 25.4 0.62 16 1.82 7.3 332 146 24.4 0.37 12 1.85 7.4 332 152 26.5 0.38 12 1.87 7.5 336 154 27.3 0.40 11 1.88 7.6 339 155 19.9 0.87 23 1.78 7.2 340 130 21.6 0.90 22 1.80 7.3 343 132 22.2 0.94 21 1.81 7.4 347 133 20.5 0.78 21 1.82 7.4 365 134 22.2 0.81 21 1.84 7.5 369 136 22.9 0.84 20 1.86 7.5 373 137 22.2 0.59 17 1.89 7.6 370 147 24.1 0.61 17 1.90 7.7 374 148 24.8 0.64 16 1.92 7.8 378 150 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 20.8 22.8 19.6 20.3 22.3 0.62 0.43 0.76 0.64 0.44 17 13 20 17 13 1.73 1.79 1.78 1.82 1.89 6.9 7.2 7.2 7.4 7.6 321 325 340 365 370 131 143 130 134 147 22.6 24.7 21.2 22.0 24.1 0.64 0.44 0.79 0.66 0.46 17 13 19 17 13 1.75 1.80 1.80 1.84 1.90 7.0 7.2 7.3 7.5 7.7 324 329 343 369 374 132 144 132 136 148 23.2 25.5 21.9 22.7 24.8 0.67 0.47 0.83 0.69 0.48 16 12 19 16 12 1.76 1.82 1.81 1.86 1.92 7.1 7.3 7.4 7.5 7.8 327 332 347 373 378 134 146 133 137 150 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 23.8 0.38 12 1.95 7.9 379 156 25.8 0.39 12 1.97 8.0 382 158 26.6 0.41 11 1.98 8.1 386 159 71 18.9 0.90 22 1.86 7.7 382 133 20.5 0.93 22 1.88 7.8 386 134 21.1 0.98 21 1.89 7.8 390 136 59 18.6 0.79 19 1.86 7.7 382 133 20.2 0.82 19 1.88 7.8 386 134 20.8 0.86 18 1.89 7.8 390 136 19.5 0.81 21 1.90 7.9 411 137 21.1 0.84 20 1.92 7.9 415 138 21.8 0.88 19 1.94 8.0 419 140 63 19.3 0.66 17 1.90 7.9 411 137 20.9 0.69 17 1.92 7.9 415 138 21.5 0.72 16 1.94 8.0 419 140 21.1 0.61 17 1.97 8.1 417 150 22.9 0.63 17 1.98 8.2 421 151 23.6 0.66 16 2.00 8.3 425 153 67 21.1 0.46 13 1.97 8.1 417 150 22.9 0.48 13 1.98 8.2 421 151 23.6 0.50 12 2.00 8.3 425 153 105 17.5 0.91 21 1.93 8.1 428 136 19.0 0.94 21 1.94 8.2 432 138 19.6 0.99 20 1.96 8.3 437 139 59 17.3 0.80 18 1.93 8.1 428 136 18.7 0.83 18 1.94 8.2 432 138 19.3 0.87 17 1.96 8.3 437 139 18.1 0.81 19 1.97 8.3 460 140 19.6 0.84 19 1.99 8.4 465 142 20.2 0.88 18 2.01 8.5 470 143 63 17.9 0.67 16 1.97 8.3 460 140 19.4 0.69 15 1.99 8.4 465 142 20.0 0.73 15 2.01 8.5 470 143 19.6 0.62 16 2.04 8.6 467 153 21.2 0.64 16 2.06 8.7 471 155 21.8 0.67 15 2.07 8.7 476 156 67 19.6 0.46 12 2.04 8.6 467 153 21.2 0.48 12 2.06 8.7 471 155 21.9 0.50 11 2.07 8.7 476 156 21.0 0.40 11 2.11 8.9 477 163 22.7 0.41 11 2.13 9.0 482 165 23.4 0.43 10 2.15 9.1 487 167 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 22.7 0.39 12 2.04 8.4 426 159 24.5 0.41 11 2.05 8.5 430 161 25.3 0.43 11 2.07 8.6 435 163 71 - 115 COOLING OPERATION MODEL: *SXC160241A* / CA*F3636*6** + TXV / MBVC1200**-1**, Design Subcooling @ AHRI 95°F Conditions, 5°F @ Serv. Vlv. EXPANDED PERFORMANCE DATA COOLING PERFORMANCE DATA ASXC160241A*-HIGH STAGE 900 800 700 900 800 700 Airflow 63 22.3 0.81 24 1.51 5.9 249 123 24.1 0.84 23 1.52 6.0 252 124 24.9 0.89 22 1.53 6.0 255 125 22.6 0.88 26 1.51 5.9 249 123 24.5 0.91 26 1.52 6.0 252 124 25.2 0.96 25 1.53 6.0 255 125 59 21.8 0.87 25 1.48 5.8 232 119 23.6 0.90 24 1.49 5.9 234 120 24.3 0.94 23 1.50 5.9 237 122 MBh 22.2 S/T 0.91 Delta T 27 KW 1.48 AMPS 5.8 232 HI PR LO PR 119 MBh 24.0 S/T 0.94 Delta T 26 KW 1.49 AMPS 5.9 HI PR 234 LO PR 120 MBh 24.8 S/T 0.99 Delta T 25.04 KW 1.50 AMPS 5.9 HI PR 237 LO PR 122 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 23.7 0.79 25 1.56 6.1 253 134 25.7 0.82 24 1.57 6.2 256 136 26.4 0.86 23 1.58 6.2 258 137 67 23.8 0.66 21 1.56 6.1 253 134 25.8 0.69 20 1.57 6.2 256 136 26.6 0.72 20 1.58 6.2 258 137 25.3 0.64 21 1.61 6.3 259 143 27.4 0.67 21 1.62 6.4 261 144 28.2 0.70 20 1.63 6.5 264 146 71 25.5 0.50 17 1.61 6.3 259 143 27.6 0.51 16 1.62 6.4 261 144 28.4 0.54 16 1.63 6.5 264 146 21.7 0.94 27 1.59 6.3 262 123 23.5 0.98 26 1.61 6.3 265 124 24.2 1.00 25 1.62 6.4 268 125 59 21.3 0.90 25 1.59 6.3 262 123 23.1 0.93 25 1.61 6.3 265 124 23.8 1.00 24 1.62 6.4 268 125 22.1 0.91 26 1.63 6.4 282 127 23.9 0.94 26 1.64 6.5 285 128 24.7 0.99 25 1.65 6.5 288 129 63 21.8 0.84 24 1.63 6.4 282 127 23.6 0.88 24 1.64 6.5 285 128 24.3 0.92 23 1.65 6.5 288 129 75 23.1 0.82 25 1.68 6.6 286 138 25.1 0.85 25 1.69 6.7 289 140 25.8 0.89 24 1.71 6.7 292 141 67 23.3 0.69 21 1.68 6.6 286 138 25.2 0.71 21 1.69 6.7 289 140 26.0 0.75 20 1.71 6.7 292 141 24.7 0.67 22 1.74 6.8 292 147 26.8 0.69 21 1.75 6.9 295 149 27.6 0.72 20 1.77 7.0 298 150 71 24.9 0.51 17 1.74 6.8 292 147 26.9 0.53 16 1.75 6.9 295 149 27.7 0.56 16 1.77 7.0 298 150 21.2 0.97 27 1.69 6.8 298 127 22.9 1.00 26 1.71 6.8 301 128 23.6 1.00 24 1.72 6.9 304 129 59 20.8 0.92 25 1.69 6.8 298 127 22.5 0.96 25 1.71 6.8 301 128 23.2 1.00 24 1.72 6.9 304 129 21.6 0.93 26 1.73 6.9 321 131 23.4 0.97 26 1.75 7.0 324 132 24.1 1.00 25 1.76 7.1 327 134 22.6 0.84 25 1.79 7.2 325 143 24.5 0.87 25 1.80 7.2 329 144 25.2 0.92 24 1.82 7.3 332 146 24.1 0.68 22 1.85 7.4 332 152 26.1 0.71 21 1.87 7.5 336 154 26.9 0.74 20 1.88 7.6 339 155 20.6 1.00 27 1.78 7.2 340 130 22.4 1.00 26 1.80 7.3 343 132 23.0 1.00 24 1.81 7.4 347 133 21.0 0.96 27 1.82 7.4 365 134 22.8 1.00 26 1.84 7.5 369 136 23.5 1.00 24 1.86 7.5 373 137 22.0 0.87 25 1.89 7.6 370 147 23.9 0.90 25 1.90 7.7 374 148 24.6 0.95 24 1.92 7.8 378 150 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 21.3 22.7 24.3 20.3 20.7 22.2 0.87 0.70 0.53 0.95 0.89 0.73 25 24 21 24 21 17 1.73 1.79 1.85 1.78 1.82 1.89 6.9 7.2 7.4 7.2 7.4 7.6 321 325 332 340 365 370 131 143 152 130 134 147 23.0 24.6 26.3 22.0 22.5 24.0 0.90 0.73 0.55 0.99 0.93 0.75 25 24 21 24 21 16 1.75 1.80 1.87 1.80 1.84 1.90 7.0 7.2 7.5 7.3 7.5 7.7 324 329 336 343 369 374 132 144 154 132 136 148 23.7 25.3 27.1 22.6 23.1 24.7 0.94 0.77 0.57 1.00 1.00 0.79 20 16 23 24 20 23 1.76 1.82 1.88 1.81 1.86 1.92 7.1 7.3 7.6 7.4 7.5 7.8 327 332 339 347 373 378 134 146 155 133 137 150 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 23.5 0.71 22 1.95 7.9 379 156 25.5 0.73 21 1.97 8.0 382 158 26.2 0.77 21 1.98 8.1 386 159 71 23.7 0.54 17 1.95 7.9 379 156 25.7 0.56 17 1.97 8.0 382 158 26.4 0.59 16 1.98 8.1 386 159 19.6 1.00 26 1.86 7.7 382 133 21.2 1.00 24 1.88 7.8 386 134 21.9 1.00 22 1.89 7.8 390 136 59 19.3 0.99 25 1.86 7.7 382 133 20.9 1.00 24 1.88 7.8 386 134 21.5 1.00 22 1.89 7.8 390 136 20.0 1.00 26 1.90 7.9 411 137 21.7 1.00 25 1.92 7.9 415 138 22.3 1.00 23 1.94 8.0 419 140 63 19.7 0.93 24 1.90 7.9 411 137 21.3 0.96 24 1.92 7.9 415 138 22.0 1.00 22 1.94 8.0 419 140 20.9 0.90 25 1.97 8.1 417 150 22.7 0.94 24 1.98 8.2 421 151 23.4 0.98 23 2.00 8.3 425 153 67 21.0 0.75 21 1.97 8.1 417 150 22.8 0.78 21 1.98 8.2 421 151 23.5 0.82 20 2.00 8.3 425 153 105 18.2 1.00 24 1.93 8.1 428 136 19.7 1.00 23 1.94 8.2 432 138 20.3 1.00 21 1.96 8.3 437 139 59 17.9 1.00 23 1.93 8.1 428 136 19.3 1.00 22 1.94 8.2 432 138 19.9 1.00 20 1.96 8.3 437 139 18.5 1.00 24 1.97 8.3 460 140 20.1 1.00 23 1.99 8.4 465 142 20.7 1.00 21 2.01 8.5 470 143 63 18.2 0.93 22 1.97 8.3 460 140 19.8 0.97 22 1.99 8.4 465 142 20.4 1.00 21 2.01 8.5 470 143 19.4 0.91 23 2.04 8.6 467 153 21.0 0.94 23 2.06 8.7 471 155 21.6 0.99 22 2.07 8.7 476 156 67 19.5 0.76 19 2.04 8.6 467 153 21.1 0.79 19 2.06 8.7 471 155 21.8 0.83 18 2.07 8.7 476 156 20.7 0.74 20 2.11 8.9 477 163 22.4 0.77 20 2.13 9.0 482 165 23.1 0.80 19 2.15 9.1 487 167 71 20.8 0.57 16 2.11 8.9 477 163 22.6 0.59 15 2.13 9.0 482 165 23.3 0.62 15 2.15 9.1 487 167 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 22.3 0.73 21 2.04 8.4 426 159 24.2 0.76 21 2.05 8.5 430 161 24.9 0.80 20 2.07 8.6 435 163 71 22.5 0.56 17 2.04 8.4 426 159 24.4 0.58 16 2.05 8.5 430 161 25.1 0.61 16 2.07 8.6 435 163 115 COOLING OPERATION MODEL: *SXC160241A* / CA*F3636*6** + TXV / MBVC1200**-1**, Design Subcooling @ AHRI 95°F Conditions, 5°F @ Serv. Vlv. EXPANDED PERFORMANCE DATA COOLING PERFORMANCE DATA ASXC160241A*-HIGH STAGE 27 28 878 780 683 878 780 683 Airflow 59 21.1 0.65 18 1.37 5.3 203 97 22.8 0.67 18 1.41 5.4 209 100 23.5 0.70 17 1.42 5.5 211 101 21.4 0.73 21 1.39 5.3 205 98 23.2 0.76 21 1.42 5.5 211 101 23.9 0.80 20 1.43 5.5 213 102 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 22.1 0.66 20 1.42 5.5 220 104 23.9 0.68 19 1.45 5.6 227 108 24.6 0.71 18 1.47 5.7 229 109 63 21.8 0.54 16 1.41 5.4 218 103 23.7 0.56 16 1.44 5.6 225 107 24.4 0.59 15 1.45 5.6 227 108 23.9 0.50 16 1.46 5.6 233 114 25.9 0.52 16 1.50 5.8 240 118 26.7 0.54 15 1.52 5.9 242 119 67 23.9 0.37 12 1.45 5.6 230 113 25.9 0.39 12 1.49 5.8 237 116 26.7 0.41 11 1.50 5.8 240 118 25.6 0.32 11 1.51 5.9 243 121 27.8 0.33 11 1.55 6.0 250 125 28.6 0.35 10 1.57 6.1 253 126 71 20.9 0.76 21 1.50 5.8 230 104 22.7 0.79 21 1.54 5.9 237 107 23.4 0.83 20 1.55 6.0 239 108 59 20.6 0.67 19 1.49 5.7 227 103 22.3 0.69 18 1.53 5.9 234 106 23.0 0.73 18 1.54 5.9 237 107 21.6 0.68 20 1.53 5.9 247 110 23.4 0.71 19 1.57 6.1 255 114 24.1 0.74 19 1.59 6.1 257 115 63 21.3 0.56 16 1.52 5.9 245 109 23.1 0.58 16 1.56 6.0 252 113 23.8 0.61 15 1.57 6.1 255 114 75 23.3 0.52 16 1.58 6.1 261 121 25.3 0.53 16 1.63 6.3 269 124 26.0 0.56 15 1.64 6.3 272 125 67 23.4 0.39 12 1.57 6.0 258 119 25.3 0.40 12 1.61 6.2 266 123 26.1 0.42 12 1.63 6.3 269 124 25.0 0.33 11 1.64 6.3 272 128 27.1 0.34 11 1.68 6.5 281 132 27.9 0.36 11 1.70 6.6 283 134 71 20.4 0.78 22 1.60 6.3 261 108 22.1 0.81 21 1.64 6.4 269 111 22.8 0.85 20 1.66 6.5 272 112 59 20.1 0.69 19 1.58 6.2 259 107 21.8 0.71 18 1.63 6.4 267 110 22.4 0.75 18 1.64 6.4 269 111 21.0 0.70 20 1.64 6.4 281 115 22.8 0.72 19 1.68 6.6 290 118 23.5 0.76 19 1.69 6.7 293 119 22.8 0.53 16 1.69 6.6 297 125 24.7 0.55 16 1.74 6.8 306 129 25.4 0.57 15 1.75 6.9 309 130 24.4 0.34 11 1.75 6.9 310 133 26.5 0.35 11 1.80 7.1 319 138 27.3 0.37 11 1.81 7.1 322 139 19.9 0.81 22 1.69 6.7 297 113 21.6 0.84 21 1.73 6.9 307 117 22.2 0.88 20 1.75 7.0 310 118 20.5 0.72 20 1.73 6.9 320 121 22.2 0.75 20 1.77 7.1 330 124 22.9 0.78 19 1.79 7.1 333 125 22.2 0.55 16 1.79 7.1 338 132 24.1 0.57 16 1.83 7.3 348 136 24.8 0.59 15 1.85 7.4 352 137 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 20.8 22.8 19.6 20.3 22.3 0.57 0.40 0.71 0.59 0.41 16 12 19 16 12 1.62 1.68 1.67 1.71 1.77 6.4 6.6 6.6 6.8 7.0 278 294 294 317 335 114 124 112 119 130 22.6 24.7 21.2 22.0 24.1 0.60 0.41 0.74 0.61 0.43 16 12 18 16 12 1.66 1.72 1.72 1.76 1.82 6.5 6.8 6.8 7.0 7.2 287 303 304 327 345 117 128 116 123 134 23.2 25.5 21.9 22.7 24.8 0.62 0.43 0.77 0.64 0.45 15 12 18 15 12 1.68 1.74 1.73 1.77 1.83 6.6 6.8 6.9 7.1 290 306 307 330 348 118 129 117 124 136 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 23.8 0.35 11 1.85 7.4 353 140 25.8 0.36 11 1.90 7.6 363 144 26.6 0.38 11 1.92 7.6 367 146 71 - EXPANDED PERFORMANCE DATA HIGH STAGE MODEL: *SXC160241B* / CA*F3636*6**+TXV+MBVC1200**-1* 18.9 0.84 21 1.76 7.1 335 119 20.5 0.87 21 1.81 7.3 345 122 21.1 0.91 20 1.83 7.4 348 124 59 18.6 0.74 18 1.75 7.1 331 118 20.2 0.76 18 1.79 7.3 342 121 20.8 0.80 17 1.81 7.3 345 122 19.5 0.75 20 1.80 7.3 360 126 21.1 0.78 19 1.85 7.5 371 130 21.8 0.81 19 1.87 7.6 375 132 63 19.3 0.61 16 1.79 7.2 356 125 20.9 0.64 16 1.84 7.4 368 129 21.5 0.67 15 1.85 7.5 371 130 21.1 0.57 16 1.87 7.5 380 138 22.9 0.59 16 1.92 7.8 392 142 23.6 0.62 15 1.93 7.8 396 144 67 21.1 0.43 12 1.85 7.5 376 136 22.9 0.44 12 1.90 7.7 388 141 23.6 0.46 11 1.92 7.8 392 142 105 17.5 0.84 20 1.83 7.6 370 123 19.0 0.88 20 1.88 7.8 381 127 19.6 0.92 19 1.89 7.8 385 128 59 17.3 0.74 17 1.81 7.5 366 122 18.7 0.77 17 1.86 7.7 377 125 19.3 0.81 16 1.88 7.8 381 127 18.1 0.75 18 1.87 7.7 398 131 19.6 0.78 18 1.92 8.0 410 135 20.2 0.82 17 1.94 8.0 414 136 63 17.9 0.62 15 1.85 7.7 394 129 19.4 0.64 15 1.90 7.9 406 133 20.0 0.67 14 1.92 8.0 410 135 19.6 0.57 15 1.93 8.0 420 143 21.2 0.59 15 1.99 8.2 433 147 21.8 0.62 14 2.00 8.3 437 148 67 19.6 0.43 11 1.92 7.9 416 141 21.2 0.45 11 1.97 8.2 429 146 21.9 0.47 11 1.99 8.2 433 147 21.0 0.37 10 2.00 8.3 438 152 22.7 0.38 10 2.06 8.5 452 157 23.4 0.40 10 2.08 8.6 456 158 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 22.7 0.36 11 1.93 7.8 397 147 24.5 0.38 11 1.98 8.1 409 151 25.3 0.40 10 2.00 8.1 413 153 71 - 115 COOLING OPERATION COOLING PERFORMANCE DATA ASXC160241B*-HIGH STAGE 878 780 683 878 780 683 Airflow 63 22.3 0.76 23 1.43 5.5 222 106 24.1 0.78 22 1.47 5.7 229 109 24.9 0.82 21 1.48 5.7 232 110 22.6 0.82 25 1.44 5.6 225 107 24.5 0.85 24 1.48 5.7 232 110 25.2 0.89 23 1.49 5.8 234 111 59 21.8 0.81 24 1.40 5.4 207 99 23.6 0.84 23 1.43 5.5 213 102 24.3 0.88 22 1.45 5.6 215 103 MBh 22.2 S/T 0.85 Delta T 25 KW 1.41 AMPS 5.4 HI PR 209 LO PR 100 MBh 24.0 S/T 0.88 Delta T 25 KW 1.45 AMPS 5.6 HI PR 215 LO PR 103 MBh 24.8 S/T 0.92 Delta T 23.85 KW 1.46 AMPS 5.6 HI PR 217 LO PR 104 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 23.7 0.74 23 1.49 5.7 237 116 25.7 0.76 23 1.53 5.9 245 120 26.4 0.80 22 1.54 6.0 247 121 67 23.8 0.62 20 1.48 5.7 235 115 25.8 0.64 19 1.52 5.9 242 119 26.6 0.67 19 1.53 5.9 245 120 25.3 0.60 20 1.54 6.0 247 124 27.4 0.62 20 1.58 6.1 255 128 28.2 0.65 19 1.59 6.2 258 129 71 25.5 0.46 16 1.53 5.9 245 123 27.6 0.48 16 1.57 6.1 253 126 28.4 0.50 15 1.58 6.1 255 128 21.7 0.88 26 1.52 5.9 234 106 23.5 0.91 25 1.57 6.0 242 109 24.2 0.95 24 1.58 6.1 244 110 59 21.3 0.84 24 1.51 5.8 232 105 23.1 0.87 24 1.55 6.0 239 108 23.8 0.91 23 1.57 6.0 242 109 22.1 0.85 25 1.56 6.0 252 113 23.9 0.88 25 1.60 6.2 260 116 24.7 0.92 24 1.61 6.2 263 117 63 21.8 0.78 23 1.55 6.0 250 112 23.6 0.81 23 1.59 6.1 257 115 24.3 0.85 22 1.60 6.2 260 116 75 23.1 0.76 24 1.61 6.2 266 123 25.1 0.79 23 1.66 6.4 274 127 25.8 0.83 22 1.67 6.4 277 128 67 23.3 0.64 20 1.60 6.2 264 122 25.2 0.66 20 1.64 6.3 272 125 26.0 0.69 19 1.66 6.4 274 127 24.7 0.62 21 1.67 6.4 278 131 26.8 0.64 20 1.71 6.6 286 135 27.6 0.67 19 1.73 6.7 289 136 71 24.9 0.48 16 1.65 6.4 275 130 26.9 0.49 16 1.70 6.6 283 134 27.7 0.52 15 1.71 6.6 286 135 21.2 0.90 26 1.63 6.4 266 110 22.9 0.93 25 1.67 6.6 275 113 23.6 0.98 24 1.68 6.6 277 115 59 20.8 0.86 24 1.61 6.3 264 109 22.5 0.89 24 1.66 6.5 272 112 23.2 0.93 23 1.67 6.6 275 113 21.6 0.87 25 1.66 6.5 287 117 23.4 0.90 25 1.71 6.7 296 121 24.1 0.94 24 1.72 6.8 299 122 22.6 0.78 24 1.72 6.8 303 128 24.5 0.81 23 1.77 6.9 312 132 25.2 0.85 22 1.78 7.0 315 133 24.1 0.63 21 1.78 7.0 316 136 26.1 0.66 20 1.83 7.2 326 140 26.9 0.69 19 1.85 7.3 329 142 20.6 0.93 26 1.72 6.8 303 116 22.4 0.96 25 1.76 7.0 313 119 23.0 1.00 24 1.78 7.1 316 120 21.0 0.89 25 1.76 7.0 327 123 22.8 0.93 25 1.80 7.2 337 127 23.5 0.97 24 1.82 7.3 340 128 22.0 0.81 24 1.82 7.2 345 134 23.9 0.84 24 1.87 7.4 356 138 24.6 0.88 23 1.88 7.5 359 140 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 21.3 22.7 24.3 20.3 20.7 22.2 0.80 0.65 0.49 0.88 0.83 0.67 23 20 16 24 23 20 1.65 1.71 1.77 1.70 1.74 1.80 6.5 6.7 6.9 6.8 6.9 7.2 284 300 313 300 323 341 116 127 135 114 122 133 23.0 24.6 26.3 22.0 22.5 24.0 0.83 0.68 0.51 0.92 0.86 0.70 23 20 16 24 23 20 1.69 1.75 1.81 1.75 1.79 1.85 6.7 6.9 7.1 7.0 7.1 7.4 293 309 322 310 333 352 119 130 139 118 125 137 23.7 25.3 27.1 22.6 23.1 24.7 0.87 0.71 0.53 0.96 0.90 0.73 22 19 15 23 22 19 1.71 1.77 1.83 1.76 1.80 1.87 6.7 6.9 7.2 7.0 7.2 7.4 296 312 326 313 337 356 121 132 140 119 127 138 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 23.5 0.65 21 1.88 7.5 360 143 25.5 0.68 20 1.93 7.7 371 147 26.2 0.71 20 1.95 7.8 375 149 71 23.7 0.50 16 1.86 7.4 356 142 25.7 0.52 16 1.92 7.6 367 146 26.4 0.55 15 1.93 7.7 371 147 EXPANDED PERFORMANCE DATA HIGH STAGE MODEL: *SXC160241B* / CA*F3636*6**+TXV+MBVC1200**-1* 19.6 0.96 25 1.79 7.3 341 121 21.2 1.00 25 1.84 7.5 352 125 21.9 1.00 23 1.86 7.5 355 126 59 19.3 0.92 24 1.78 7.2 338 120 20.9 0.95 23 1.83 7.4 348 124 21.5 1.00 23 1.84 7.5 352 125 20.0 0.93 25 1.83 7.4 367 129 21.7 0.96 25 1.88 7.7 379 133 22.3 1.00 23 1.90 7.7 383 134 63 19.7 0.86 23 1.82 7.4 364 128 21.3 0.89 22 1.87 7.6 375 132 22.0 0.94 22 1.88 7.7 379 133 20.9 0.84 24 1.90 7.7 388 141 22.7 0.87 23 1.95 7.9 400 145 23.4 0.91 22 1.97 8.0 404 146 67 21.0 0.70 20 1.88 7.6 384 139 22.8 0.73 20 1.93 7.8 396 144 23.5 0.76 19 1.95 7.9 400 145 105 18.2 0.97 24 1.86 7.7 377 125 19.7 1.00 23 1.91 7.9 389 129 20.3 1.00 21 1.93 8.0 393 130 59 17.9 0.93 22 1.84 7.6 373 124 19.3 0.96 22 1.89 7.8 385 128 19.9 1.00 21 1.91 7.9 389 129 18.5 0.94 23 1.90 7.9 406 133 20.1 0.97 23 1.95 8.1 418 137 20.7 1.00 22 1.97 8.2 423 139 63 18.2 0.87 21 1.89 7.8 402 132 19.8 0.90 21 1.94 8.0 414 136 20.4 0.94 20 1.95 8.1 418 137 19.4 0.84 22 1.97 8.1 429 145 21.0 0.88 22 2.02 8.4 442 150 21.6 0.92 21 2.04 8.5 446 151 67 19.5 0.71 19 1.95 8.1 424 144 21.1 0.73 18 2.00 8.3 438 149 21.8 0.77 18 2.02 8.4 442 150 20.7 0.69 19 2.04 8.5 447 155 22.4 0.71 19 2.09 8.7 461 160 23.1 0.75 18 2.11 8.8 466 161 71 20.8 0.53 15 2.02 8.4 443 153 22.6 0.55 15 2.08 8.6 456 158 23.3 0.57 14 2.09 8.7 461 160 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 22.3 0.68 20 1.97 8.0 405 150 24.2 0.70 20 2.02 8.2 417 154 24.9 0.74 19 2.04 8.3 421 156 71 22.5 0.52 16 1.95 7.9 401 148 24.4 0.54 16 2.00 8.1 413 153 25.1 0.57 15 2.02 8.2 417 154 115 COOLING OPERATION COOLING PERFORMANCE DATA ASXC160241B*-HIGH STAGE 29 30 1356 1200 1043 1356 1200 1043 Airflow 34.1 0.57 15 2.17 8.2 247 119 35.1 0.60 14 2.18 8.3 249 120 32.9 0.68 17 2.12 8.0 230 115 33.9 0.72 17 2.14 8.1 232 116 30.9 0.75 20 2.10 8.0 227 114 33.5 0.78 20 2.12 8.0 230 115 34.5 0.82 19 2.14 8.1 232 116 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 31.8 0.67 19 2.15 8.2 244 117 34.5 0.70 18 2.17 8.2 247 119 35.5 0.73 18 2.18 8.3 249 120 63 31.5 0.55 15 2.15 8.2 244 117 59 MBh 30.4 S/T 0.66 Delta T 18 KW 2.10 AMPS 8.0 HI PR 227 LO PR 114 34.4 0.51 15 2.22 8.4 248 128 37.3 0.53 15 2.24 8.5 250 129 38.4 0.55 14 2.25 8.6 253 131 37.4 0.40 11 2.24 8.5 250 129 38.5 0.42 11 2.25 8.6 253 131 67 34.5 0.38 12 2.22 8.4 248 128 37.0 0.33 11 2.29 8.7 253 136 40.0 0.34 10 2.31 8.8 256 138 41.2 0.36 10 2.33 8.9 259 139 - 71 - 30.2 0.78 21 2.27 8.6 257 117 32.7 0.81 20 2.29 8.7 260 118 33.7 0.85 19 2.31 8.8 262 119 32.2 0.71 17 2.29 8.7 260 118 33.1 0.74 17 2.31 8.8 262 119 59 29.7 0.68 18 2.27 8.6 257 117 31.1 0.70 19 2.32 8.8 276 121 33.7 0.72 19 2.34 8.9 279 122 34.7 0.76 18 2.36 9.0 282 123 33.3 0.59 15 2.34 8.9 279 122 34.3 0.62 14 2.36 9.0 282 123 63 30.8 0.57 15 2.32 8.8 276 121 75 33.6 0.53 16 2.39 9.1 280 132 36.4 0.55 15 2.41 9.2 283 133 37.5 0.57 15 2.43 9.3 286 135 36.5 0.41 11 2.41 9.2 283 133 37.6 0.43 11 2.43 9.3 286 135 67 33.7 0.40 12 2.39 9.1 280 132 36.1 0.34 11 2.47 9.4 286 140 39.1 0.35 11 2.49 9.5 289 142 40.3 0.37 10 2.51 9.6 292 143 - 71 - 29.5 0.80 21 2.41 9.3 292 121 31.9 0.83 20 2.43 9.4 295 122 32.9 0.87 19 2.45 9.5 298 124 31.4 0.73 18 2.43 9.4 295 122 32.3 0.76 17 2.45 9.5 298 124 30.3 0.71 19 2.47 9.6 314 125 32.9 0.74 19 2.49 9.6 317 126 33.8 0.78 18 2.51 9.7 321 127 32.5 0.61 15 2.49 9.6 317 126 33.5 0.64 14 2.51 9.7 321 127 32.8 0.54 16 2.55 9.9 319 136 35.6 0.56 15 2.57 10.0 322 138 36.6 0.59 15 2.59 10.0 325 139 35.6 0.42 11 2.57 10.0 322 138 36.7 0.44 11 2.59 10.0 325 139 35.2 0.35 11 2.63 10.2 326 145 38.2 0.36 11 2.66 10.3 329 147 39.3 0.38 10 2.68 10.4 332 148 28.7 0.82 21 2.54 10.0 333 124 31.1 0.85 20 2.56 10.1 336 126 32.1 0.90 19 2.58 10.1 340 127 30.6 0.75 18 2.56 10.1 336 126 31.5 0.79 17 2.58 10.1 340 127 29.6 0.74 19 2.60 10.2 358 128 32.1 0.76 19 2.62 10.3 362 130 33.0 0.80 18 2.64 10.4 365 131 31.7 0.63 15 2.62 10.3 362 130 32.7 0.66 15 2.64 10.4 365 131 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 29.0 30.0 32.9 28.3 29.3 0.70 0.59 0.41 0.72 0.61 18 16 12 18 16 2.41 2.47 2.55 2.54 2.60 9.3 9.6 9.9 10.0 10.2 292 314 319 333 358 121 125 136 124 128 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 32.0 0.56 16 2.68 10.5 363 140 34.7 0.58 15 2.71 10.6 367 141 35.7 0.61 15 2.73 10.7 370 143 34.8 0.43 12 2.71 10.6 367 141 35.8 0.46 11 2.73 10.7 370 143 67 32.1 0.42 12 2.68 10.5 363 140 34.4 0.36 11 2.78 10.9 371 149 37.2 0.37 11 2.80 11.0 375 151 38.4 0.39 10 2.82 11.1 379 152 - 71 - 27.3 0.85 21 2.65 10.6 360 127 29.6 0.89 20 2.67 10.7 363 128 30.5 0.93 19 2.69 10.8 367 129 29.1 0.78 17 2.67 10.7 363 128 30.0 0.82 17 2.69 10.8 367 129 59 26.9 0.75 18 2.65 10.6 360 127 28.1 0.76 19 2.71 10.9 387 131 30.5 0.79 19 2.73 11.0 390 132 31.4 0.83 18 2.76 11.1 394 133 30.2 0.65 15 2.73 11.0 390 132 31.1 0.68 14 2.76 11.1 394 133 63 27.8 0.63 15 2.71 10.9 387 131 30.4 0.58 16 2.80 11.2 392 143 33.0 0.60 15 2.82 11.3 396 144 34.0 0.63 14 2.85 11.4 400 146 33.0 0.45 11 2.82 11.3 396 144 34.0 0.47 11 2.85 11.4 400 146 67 30.5 0.44 12 2.80 11.2 392 143 105 25.3 0.86 19 2.74 11.2 426 130 27.4 0.89 19 2.77 11.3 430 131 28.2 0.94 18 2.79 11.4 435 133 26.9 0.79 16 2.77 11.3 430 131 27.8 0.82 16 2.79 11.4 435 133 59 24.9 0.76 17 2.74 11.2 426 130 26.0 0.77 18 2.81 11.5 458 134 28.2 0.80 17 2.83 11.6 463 135 29.1 0.84 17 2.85 11.7 467 137 27.9 0.66 14 2.83 11.6 463 135 28.8 0.69 13 2.85 11.7 467 137 63 25.8 0.63 14 2.81 11.5 458 134 28.2 0.58 14 2.90 11.9 465 146 30.5 0.61 14 2.93 12.0 469 148 31.5 0.63 14 2.95 12.1 474 149 30.6 0.45 11 2.93 12.0 469 148 31.5 0.48 10 2.95 12.1 474 149 67 28.2 0.44 11 2.90 11.9 465 146 30.3 0.38 10 3.00 12.3 475 156 32.8 0.39 10 3.03 12.4 480 157 33.8 0.41 9 3.05 12.6 484 159 - 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 32.7 0.37 11 2.90 11.6 401 152 35.4 0.39 10 2.92 11.7 405 154 36.4 0.40 10 2.95 11.9 409 155 - 71 - 115 MODEL: *SXC160361A* / CA*F3743*6** + TXV / MBVC1600**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA COOLING PERFORMANCE DATA ASXC160361A*-HIGH STAGE 1356 1200 1043 1356 1200 1043 Airflow 59 31.4 0.82 23 2.10 8.0 227 114 34.1 0.85 22 2.12 8.0 230 115 35.1 0.90 21 2.14 8.1 232 116 32.0 0.86 24 2.10 8.0 227 114 34.7 0.90 24 2.12 8.0 230 115 35.7 0.94 23 2.14 8.1 232 116 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 32.6 0.83 24 2.15 8.2 244 117 35.3 0.86 23 2.17 8.2 247 119 36.4 0.91 22 2.18 8.3 249 120 63 32.1 0.77 22 2.15 8.2 244 117 34.8 0.80 21 2.17 8.2 247 119 35.9 0.84 20 2.18 8.3 249 120 34.2 0.75 23 2.22 8.4 248 128 37.0 0.78 22 2.24 8.5 250 129 38.1 0.82 21 2.25 8.6 253 131 67 34.3 0.63 19 2.22 8.4 248 128 37.2 0.65 19 2.24 8.5 250 129 38.3 0.68 18 2.25 8.6 253 131 36.4 0.61 20 2.29 8.7 253 136 39.5 0.63 19 2.31 8.8 256 138 40.7 0.66 18 2.33 8.9 259 139 71 36.7 0.47 15 2.29 8.7 253 136 39.8 0.49 15 2.31 8.8 256 138 41.0 0.51 14 2.33 8.9 259 139 31.3 0.89 25 2.27 8.6 257 117 33.9 0.93 24 2.29 8.7 260 118 34.9 0.97 23 2.31 8.8 262 119 59 30.7 0.85 23 2.27 8.6 257 117 33.3 0.88 23 2.29 8.7 260 118 34.3 0.93 22 2.31 8.8 262 119 31.9 0.86 24 2.32 8.8 276 121 34.5 0.90 24 2.34 8.9 279 122 35.6 0.94 23 2.36 9.0 282 123 63 31.4 0.80 22 2.32 8.8 276 121 34.0 0.83 22 2.34 8.9 279 122 35.0 0.87 21 2.36 9.0 282 123 75 33.4 0.78 23 2.39 9.1 280 132 36.1 0.81 22 2.41 9.2 283 133 37.2 0.85 21 2.43 9.3 286 135 67 33.5 0.65 19 2.39 9.1 280 132 36.3 0.68 19 2.41 9.2 283 133 37.4 0.71 18 2.43 9.3 286 135 35.6 0.63 20 2.47 9.4 286 140 38.6 0.66 19 2.49 9.5 289 142 39.7 0.69 19 2.51 9.6 292 143 71 35.8 0.49 15 2.47 9.4 286 140 38.8 0.50 15 2.49 9.5 289 142 40.0 0.53 14 2.51 9.6 292 143 30.5 0.92 25 2.41 9.3 292 121 33.1 0.95 24 2.43 9.4 295 122 34.0 1.00 23 2.45 9.5 298 124 59 30.0 0.87 23 2.41 9.3 292 121 32.5 0.91 23 2.43 9.4 295 122 33.5 0.95 22 2.45 9.5 298 124 31.1 0.89 24 2.47 9.6 314 125 33.7 0.92 24 2.49 9.6 317 126 34.7 0.96 23 2.51 9.7 321 127 32.6 0.80 23 2.55 9.9 319 136 35.3 0.83 22 2.57 10.0 322 138 36.3 0.87 21 2.59 10.0 325 139 34.7 0.65 20 2.63 10.2 326 145 37.6 0.67 19 2.66 10.3 329 147 38.8 0.70 19 2.68 10.4 332 148 29.8 0.95 25 2.54 10.0 333 124 32.2 0.98 24 2.56 10.1 336 126 33.2 1.00 23 2.58 10.1 340 127 30.3 0.91 24 2.60 10.2 358 128 32.9 0.95 24 2.62 10.3 362 130 33.9 0.99 23 2.64 10.4 365 131 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 30.6 32.7 35.0 29.3 29.9 0.82 0.67 0.50 0.90 0.85 22 19 15 23 22 2.47 2.55 2.63 2.54 2.60 9.6 9.9 10.2 10.0 10.2 314 319 326 333 358 125 136 145 124 128 33.2 35.5 37.9 31.7 32.4 0.85 0.69 0.52 0.94 0.88 22 19 15 23 22 2.49 2.57 2.66 2.56 2.62 9.6 10.0 10.3 10.1 10.3 317 322 329 336 362 126 138 147 126 130 34.2 36.5 39.0 32.6 33.4 0.89 0.73 0.54 1.00 0.92 21 18 14 22 21 2.51 2.59 2.68 2.58 2.64 9.7 10.0 10.4 10.1 10.4 321 325 332 340 365 127 139 148 127 131 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 31.8 0.82 23 2.68 10.5 363 140 34.4 0.86 23 2.71 10.6 367 141 35.5 0.90 22 2.73 10.7 370 143 67 31.9 0.69 19 2.68 10.5 363 140 34.6 0.71 19 2.71 10.6 367 141 35.6 0.75 18 2.73 10.7 370 143 33.9 0.67 20 2.78 10.9 371 149 36.7 0.69 20 2.80 11.0 375 151 37.8 0.73 19 2.82 11.1 379 152 71 34.1 0.52 16 2.78 10.9 371 149 37.0 0.53 15 2.80 11.0 375 151 38.1 0.56 14 2.82 11.1 379 152 28.3 0.98 24 2.65 10.6 360 127 30.6 1.00 23 2.67 10.7 363 128 31.6 1.00 21 2.69 10.8 367 129 59 27.8 0.94 23 2.65 10.6 360 127 30.1 0.97 22 2.67 10.7 363 128 31.0 1.00 21 2.69 10.8 367 129 28.8 0.95 24 2.71 10.9 387 131 31.2 0.98 24 2.73 11.0 390 132 32.2 1.00 22 2.76 11.1 394 133 63 28.4 0.88 22 2.71 10.9 387 131 30.8 0.91 21 2.73 11.0 390 132 31.7 0.96 21 2.76 11.1 394 133 30.2 0.86 23 2.80 11.2 392 143 32.7 0.89 22 2.82 11.3 396 144 33.7 0.93 21 2.85 11.4 400 146 67 30.3 0.72 19 2.80 11.2 392 143 32.9 0.74 19 2.82 11.3 396 144 33.9 0.78 18 2.85 11.4 400 146 105 26.2 0.99 23 2.74 11.2 426 130 28.4 1.00 22 2.77 11.3 430 131 29.2 1.00 20 2.79 11.4 435 133 59 25.7 0.95 21 2.74 11.2 426 130 27.9 0.98 21 2.77 11.3 430 131 28.7 1.00 19 2.79 11.4 435 133 26.7 0.96 22 2.81 11.5 458 134 28.9 0.99 22 2.83 11.6 463 135 29.8 1.00 20 2.85 11.7 467 137 63 26.3 0.89 21 2.81 11.5 458 134 28.5 0.92 20 2.83 11.6 463 135 29.4 0.96 19 2.85 11.7 467 137 28.0 0.86 21 2.90 11.9 465 146 30.3 0.89 21 2.93 12.0 469 148 31.2 0.94 20 2.95 12.1 474 149 67 28.1 0.72 18 2.90 11.9 465 146 30.4 0.75 17 2.93 12.0 469 148 31.4 0.78 17 2.95 12.1 474 149 29.8 0.70 18 3.00 12.3 475 156 32.3 0.73 18 3.03 12.4 480 157 33.3 0.76 17 3.05 12.6 484 159 71 30.0 0.54 14 3.00 12.3 475 156 32.5 0.56 14 3.03 12.4 480 157 33.5 0.59 13 3.05 12.6 484 159 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 32.2 0.69 20 2.90 11.6 401 152 34.9 0.72 19 2.92 11.7 405 154 35.9 0.75 18 2.95 11.9 409 155 71 32.4 0.53 15 2.90 11.6 401 152 35.1 0.55 15 2.92 11.7 405 154 36.2 0.58 14 2.95 11.9 409 155 115 COOLING OPERATION MODEL: *SXC160361A* / CA*F3743*6** + TXV / MBVC1600**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA COOLING PERFORMANCE DATA ASXC160361A*-HIGH STAGE 31 32 1294 1150 1006 1294 1150 1006 Airflow 59 30.7 0.67 19 2.09 8.4 216 101 33.3 0.70 19 2.14 8.6 222 104 34.3 0.73 18 2.16 8.7 225 105 31.3 0.77 22 2.11 8.4 218 102 33.9 0.79 22 2.16 8.7 225 105 34.9 0.83 21 2.18 8.8 227 106 MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR 32.2 0.69 20 2.15 8.6 235 108 34.9 0.71 20 2.21 8.9 242 112 35.9 0.75 19 2.23 9.0 244 113 63 31.9 0.56 16 2.14 8.6 232 107 34.5 0.58 16 2.19 8.8 239 111 35.5 0.61 15 2.21 8.9 242 112 34.8 0.52 17 2.23 8.9 248 118 37.7 0.54 16 2.28 9.2 255 122 38.9 0.56 16 2.30 9.3 258 123 67 34.9 0.39 12 2.21 8.8 245 117 37.8 0.40 12 2.26 9.1 253 121 38.9 0.42 12 2.28 9.2 255 122 37.4 0.33 11 2.30 9.3 258 126 40.5 0.35 11 2.36 9.5 266 130 41.7 0.36 11 2.38 9.6 269 131 71 30.5 0.79 22 2.28 9.1 245 108 33.1 0.82 22 2.34 9.4 252 111 34.1 0.86 21 2.36 9.5 255 112 59 30.0 0.70 19 2.26 9.0 242 106 32.5 0.72 19 2.32 9.3 250 110 33.5 0.76 18 2.34 9.4 252 111 31.4 0.71 20 2.33 9.4 263 114 34.1 0.74 20 2.39 9.6 271 118 35.1 0.77 19 2.41 9.7 274 119 63 31.1 0.58 17 2.31 9.3 261 113 33.7 0.61 16 2.37 9.5 269 117 34.7 0.63 16 2.39 9.6 271 118 75 34.0 0.54 17 2.40 9.7 278 125 36.9 0.56 16 2.47 9.9 287 129 38.0 0.58 16 2.49 10.0 289 130 67 34.1 0.40 13 2.38 9.6 275 124 36.9 0.42 12 2.45 9.9 284 127 38.0 0.44 12 2.47 9.9 287 129 36.5 0.35 12 2.49 10.0 290 133 39.6 0.36 11 2.55 10.3 299 137 40.7 0.38 11 2.57 10.4 302 139 71 29.8 0.81 22 2.43 9.9 278 112 32.3 0.84 22 2.49 10.2 287 115 33.3 0.89 21 2.51 10.3 290 116 59 29.3 0.72 19 2.40 9.8 275 111 31.7 0.74 19 2.47 10.1 284 114 32.7 0.78 18 2.49 10.2 287 115 30.7 0.73 20 2.48 10.2 299 119 33.2 0.76 20 2.55 10.5 309 123 34.2 0.79 19 2.57 10.6 312 124 33.2 0.55 17 2.56 10.5 316 130 36.0 0.57 16 2.63 10.8 326 134 37.1 0.60 16 2.65 10.9 329 135 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 35.6 0.35 12 2.65 10.9 330 138 38.6 0.37 11 2.72 11.2 340 143 39.8 0.39 11 2.75 11.3 343 144 29.1 0.84 22 2.56 10.6 317 117 31.5 0.87 22 2.62 10.9 327 121 32.4 0.91 21 2.65 11.0 330 122 29.9 0.75 21 2.61 10.9 341 125 32.4 0.78 20 2.68 11.2 352 129 33.4 0.82 19 2.71 11.3 355 130 Outdoor Ambient Temperature 95 85 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 30.4 33.3 28.6 29.6 0.60 0.41 0.74 0.62 17 13 19 17 2.46 2.54 2.53 2.59 10.1 10.4 10.5 10.8 296 313 314 338 118 129 116 124 32.9 36.1 31.0 32.1 0.62 0.43 0.77 0.64 16 12 19 16 2.52 2.61 2.60 2.66 10.4 10.7 10.8 11.1 306 323 323 348 121 132 120 127 33.9 37.1 31.9 33.1 0.65 0.45 0.80 0.67 16 12 18 16 2.54 2.63 2.62 2.68 10.5 10.8 10.9 11.2 309 326 327 352 123 134 121 129 32.4 0.57 17 2.70 11.3 360 136 35.1 0.59 17 2.78 11.6 371 141 36.2 0.62 16 2.80 11.7 375 142 67 32.5 0.43 13 2.68 11.2 356 135 35.2 0.44 12 2.75 11.5 368 139 36.2 0.47 12 2.78 11.6 371 141 71 34.8 0.37 12 2.80 11.7 376 145 37.7 0.38 11 2.87 12.0 387 150 38.8 0.40 11 2.90 12.1 391 151 EXPANDED PERFORMANCE DATA MODEL: *SXC160361B* / CA*F3743*6**+TXV+MBVC1600**-1* HIGH STAGE 27.6 0.87 22 2.67 11.3 357 123 29.9 0.90 22 2.74 11.7 368 127 30.8 0.95 21 2.76 11.8 371 128 59 27.2 0.77 19 2.64 11.2 353 122 29.4 0.80 19 2.72 11.5 364 126 30.3 0.83 18 2.74 11.7 367 127 28.4 0.78 20 2.73 11.6 384 131 30.8 0.81 20 2.80 11.9 396 135 31.7 0.85 19 2.83 12.1 399 136 63 28.2 0.64 16 2.71 11.5 380 130 30.5 0.66 16 2.78 11.8 392 134 31.4 0.70 16 2.80 11.9 395 135 30.8 0.59 17 2.82 12.0 405 143 33.3 0.61 16 2.90 12.4 418 147 34.4 0.64 16 2.92 12.5 422 149 67 30.8 0.44 13 2.80 11.9 401 141 33.4 0.46 12 2.87 12.2 413 146 34.4 0.48 12 2.90 12.3 418 147 105 25.6 0.88 21 2.76 12.0 394 127 27.7 0.91 20 2.84 12.4 406 131 28.6 0.96 19 2.86 12.5 410 133 59 25.2 0.77 18 2.74 11.9 390 126 27.3 0.80 17 2.81 12.2 402 130 28.1 0.84 17 2.84 12.4 406 131 26.3 0.79 19 2.83 12.3 424 135 28.5 0.82 19 2.90 12.7 437 140 29.4 0.86 18 2.93 12.8 441 141 63 26.1 0.65 15 2.80 12.2 420 134 28.3 0.67 15 2.88 12.5 433 138 29.1 0.70 15 2.90 12.7 437 140 28.5 0.60 16 2.93 12.7 448 148 30.9 0.62 15 3.00 13.1 461 152 31.8 0.65 15 3.03 13.2 466 154 67 28.6 0.45 12 2.90 12.6 443 146 31.0 0.46 11 2.98 13.0 457 151 31.9 0.49 11 3.00 13.1 461 152 30.6 0.38 11 3.03 13.2 467 157 33.2 0.40 11 3.11 13.6 481 162 34.2 0.42 10 3.14 13.7 486 164 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 33.0 0.38 11 2.92 12.5 423 152 35.8 0.39 11 3.00 12.8 436 157 36.9 0.41 11 3.03 13.0 440 158 71 - 115 COOLING PERFORMANCE DATA ASXC160361B*-HIGH STAGE 1294 1150 1006 1294 1150 1006 Airflow 59 31.8 0.84 24 2.13 8.5 220 103 34.5 0.87 24 2.18 8.8 227 106 35.5 0.91 23 2.20 8.8 229 107 32.4 0.88 26 2.14 8.6 222 104 35.1 0.91 26 2.20 8.8 229 107 36.1 0.96 25 2.22 8.9 232 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 33.0 0.85 26 2.19 8.8 239 110 35.7 0.88 25 2.25 9.1 247 114 36.8 0.92 24 2.27 9.1 249 115 63 32.5 0.79 23 2.17 8.7 237 109 35.2 0.82 23 2.23 9.0 244 113 36.3 0.86 22 2.25 9.1 247 114 34.6 0.77 24 2.26 9.1 253 121 37.4 0.80 24 2.32 9.4 261 124 38.6 0.83 23 2.34 9.4 263 126 67 34.7 0.64 20 2.24 9.0 250 119 37.6 0.67 20 2.30 9.3 258 123 38.8 0.70 19 2.32 9.4 261 124 36.9 0.62 21 2.34 9.4 264 128 39.9 0.65 21 2.40 9.7 272 132 41.1 0.68 20 2.42 9.8 275 134 71 37.1 0.48 16 2.32 9.4 261 127 40.2 0.50 16 2.38 9.6 269 131 41.4 0.52 15 2.40 9.7 272 132 31.6 0.91 26 2.32 9.3 250 110 34.3 0.95 26 2.38 9.6 257 113 35.3 0.99 25 2.40 9.7 260 114 59 31.1 0.87 25 2.30 9.2 247 109 33.7 0.90 24 2.36 9.5 255 112 34.7 0.95 23 2.38 9.6 257 113 32.2 0.88 26 2.37 9.5 269 117 34.9 0.91 26 2.43 9.8 277 120 36.0 0.96 24 2.45 9.9 280 122 63 31.7 0.82 24 2.35 9.4 266 116 34.4 0.85 23 2.41 9.7 274 119 35.4 0.89 22 2.43 9.8 277 120 75 33.8 0.80 25 2.45 9.8 284 127 36.6 0.82 24 2.51 10.1 292 131 37.7 0.86 23 2.53 10.2 295 133 67 33.9 0.67 21 2.43 9.8 281 126 36.8 0.69 20 2.49 10.0 290 130 37.9 0.72 19 2.51 10.1 292 131 36.0 0.65 21 2.53 10.2 296 136 39.0 0.67 21 2.60 10.5 305 140 40.2 0.70 20 2.62 10.6 308 141 71 36.3 0.50 16 2.51 10.1 293 134 39.3 0.52 16 2.57 10.4 302 139 40.5 0.54 16 2.60 10.5 305 140 30.9 0.94 26 2.47 10.1 284 114 33.4 0.97 26 2.53 10.4 293 118 34.4 1.00 24 2.55 10.5 296 119 59 30.3 0.89 25 2.45 10.0 281 113 32.9 0.93 24 2.51 10.3 290 116 33.8 1.00 24 2.53 10.4 293 118 31.5 0.90 26 2.52 10.4 305 121 34.1 0.94 26 2.59 10.7 315 125 35.1 0.98 25 2.61 10.8 318 126 32.9 0.82 25 2.61 10.7 323 132 35.7 0.85 24 2.68 11.0 333 137 36.8 0.89 23 2.70 11.1 336 138 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 35.1 0.66 21 2.70 11.1 336 141 38.1 0.69 21 2.77 11.5 347 145 39.2 0.72 20 2.79 11.6 350 147 30.1 0.97 27 2.60 10.8 323 120 32.6 1.00 26 2.67 11.1 333 123 33.6 1.00 24 2.69 11.2 337 125 30.7 0.93 26 2.66 11.1 348 127 33.3 0.97 26 2.73 11.4 359 131 34.2 1.00 24 2.75 11.5 362 133 Outdoor Ambient Temperature 95 85 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 31.0 33.1 35.4 29.6 30.2 0.84 0.68 0.51 0.92 0.86 24 21 16 25 24 2.50 2.59 2.67 2.58 2.64 10.3 10.6 11.0 10.7 11.0 302 319 333 320 344 120 131 140 119 126 33.6 35.9 38.4 32.1 32.8 0.87 0.71 0.53 0.96 0.90 23 20 16 25 23 2.57 2.65 2.75 2.65 2.71 10.6 10.9 11.3 11.0 11.3 312 329 343 330 355 124 135 144 122 130 34.6 37.0 39.5 33.0 33.7 0.91 0.74 0.55 1.00 0.94 22 19 16 23 23 2.59 2.68 2.77 2.67 2.73 10.7 11.0 11.5 11.1 11.4 315 333 347 333 359 125 137 145 123 131 32.1 0.84 25 2.75 11.5 367 139 34.8 0.87 24 2.82 11.8 379 143 35.9 0.92 23 2.85 11.9 383 145 67 32.3 0.70 21 2.73 11.4 364 138 35.0 0.73 20 2.80 11.7 375 142 36.1 0.77 20 2.82 11.8 379 143 34.3 0.68 21 2.85 11.9 383 148 37.2 0.71 21 2.92 12.3 395 153 38.3 0.74 20 2.95 12.4 399 154 71 34.5 0.53 17 2.82 11.8 379 147 37.4 0.55 16 2.90 12.2 391 151 38.5 0.57 16 2.92 12.3 395 153 EXPANDED PERFORMANCE DATA MODEL: *SXC160361B* / CA*F3743*6**+TXV+MBVC1600**-1* HIGH STAGE 28.6 1.00 26 2.71 11.5 364 126 31.0 1.00 25 2.79 11.9 375 129 31.9 1.00 23 2.81 12.0 379 131 59 28.1 0.96 25 2.69 11.4 360 124 30.5 0.99 24 2.76 11.8 371 128 31.4 1.00 22 2.79 11.9 375 129 29.2 0.97 26 2.78 11.8 391 134 31.6 1.00 25 2.85 12.2 404 138 32.5 1.00 23 2.88 12.3 408 139 63 28.7 0.90 24 2.75 11.7 388 132 31.1 0.93 23 2.83 12.1 400 136 32.1 1.00 23 2.85 12.2 404 138 30.5 0.87 24 2.87 12.2 413 146 33.1 0.91 24 2.95 12.6 426 150 34.1 0.95 23 2.98 12.7 430 152 67 30.7 0.73 20 2.85 12.1 409 144 33.3 0.76 20 2.92 12.5 422 149 34.2 0.79 19 2.95 12.6 426 150 105 26.5 1.00 24 2.81 12.2 402 130 28.7 1.00 23 2.89 12.6 414 134 29.6 1.00 21 2.91 12.7 418 135 59 26.0 0.97 23 2.79 12.1 398 129 28.2 1.00 23 2.86 12.5 410 133 29.1 1.00 21 2.89 12.6 414 134 27.0 0.98 24 2.88 12.5 432 138 29.3 1.00 23 2.96 12.9 446 142 30.1 1.00 21 2.98 13.0 450 144 63 26.6 0.91 22 2.85 12.4 428 137 28.8 0.94 22 2.93 12.8 441 141 29.7 1.00 21 2.96 12.9 446 142 28.3 0.88 23 2.98 13.0 457 151 30.6 0.91 22 3.06 13.4 471 155 31.6 0.96 21 3.08 13.5 475 157 67 28.4 0.74 19 2.95 12.9 452 149 30.8 0.76 19 3.03 13.2 466 154 31.7 0.80 18 3.06 13.4 471 155 30.2 0.71 20 3.08 13.5 476 161 32.7 0.74 19 3.16 13.9 491 166 33.7 0.78 19 3.19 14.0 496 167 71 30.4 0.55 15 3.05 13.4 472 159 32.9 0.57 15 3.14 13.7 486 164 33.9 0.60 14 3.16 13.9 491 166 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 32.6 0.71 21 2.97 12.7 431 155 35.3 0.74 21 3.05 13.1 444 160 36.4 0.77 20 3.08 13.2 449 162 71 32.8 0.55 16 2.95 12.6 427 154 35.5 0.57 16 3.03 13.0 440 158 36.6 0.59 15 3.05 13.1 444 160 115 COOLING OPERATION COOLING PERFORMANCE DATA ASXC160361B*-HIGH STAGE 33 34 1800 1600 1400 1800 1600 1400 Airflow 59 41.3 0.68 19 2.93 14.2 226 100 44.7 0.71 18 3.01 14.5 233 103 46.1 0.74 17 3.03 14.6 235 104 42.0 0.78 21 2.96 14.3 228 101 45.5 0.81 21 3.03 14.6 235 104 46.8 0.84 20 3.06 14.7 237 105 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 43.2 0.69 20 3.02 14.5 245 108 46.8 0.72 19 3.10 14.9 253 111 48.2 0.76 19 3.12 15.0 255 112 63 42.8 0.57 16 3.00 14.4 243 106 46.3 0.59 16 3.07 14.8 250 110 47.7 0.62 15 3.10 14.9 253 111 46.8 0.53 16 3.12 14.9 259 117 50.7 0.55 16 3.20 15.3 267 121 52.2 0.57 15 3.22 15.4 270 122 67 46.9 0.40 12 3.09 14.8 256 116 50.8 0.41 12 3.17 15.1 264 120 52.3 0.43 11 3.19 15.3 267 121 50.2 0.34 11 3.22 15.4 270 125 54.4 0.35 11 3.30 15.7 278 129 56.0 0.37 11 3.33 15.9 281 130 71 41.0 0.81 22 3.19 15.2 256 107 44.4 0.84 21 3.27 15.5 264 110 45.7 0.88 20 3.29 15.7 266 111 59 40.3 0.71 19 3.16 15.1 253 106 43.7 0.73 18 3.24 15.4 261 109 45.0 0.77 18 3.27 15.5 264 110 42.2 0.72 20 3.26 15.5 275 114 45.7 0.75 20 3.34 15.9 284 117 47.1 0.78 19 3.37 16.0 287 118 63 41.8 0.59 16 3.23 15.4 272 112 45.3 0.61 16 3.31 15.7 281 116 46.6 0.64 15 3.34 15.9 284 117 75 45.7 0.55 16 3.36 15.9 291 124 49.5 0.57 16 3.45 16.3 300 128 51.0 0.59 15 3.48 16.4 303 129 67 45.8 0.41 12 3.33 15.8 288 123 49.6 0.43 12 3.42 16.2 297 127 51.1 0.45 12 3.45 16.3 300 128 49.0 0.35 11 3.47 16.4 303 132 53.1 0.36 11 3.56 16.8 312 136 54.7 0.38 11 3.59 16.9 316 138 71 40.0 0.83 22 3.39 16.3 291 111 43.4 0.86 21 3.48 16.7 300 114 44.7 0.90 20 3.51 16.8 303 116 59 39.4 0.73 19 3.36 16.1 288 110 42.6 0.75 18 3.45 16.5 297 113 43.9 0.79 18 3.48 16.7 300 114 41.2 0.74 20 3.46 16.6 313 118 44.6 0.77 20 3.55 17.0 323 122 46.0 0.80 19 3.58 17.1 326 123 44.6 0.56 16 3.58 17.1 331 129 48.3 0.58 16 3.67 17.5 341 133 49.8 0.61 15 3.70 17.6 344 134 47.9 0.36 11 3.70 17.6 345 137 51.9 0.37 11 3.79 18.0 355 142 53.4 0.39 11 3.83 18.2 359 143 39.0 0.85 22 3.57 17.2 331 117 42.3 0.88 21 3.66 17.6 342 120 43.6 0.93 21 3.69 17.8 345 121 40.2 0.76 20 3.65 17.6 356 124 43.6 0.79 20 3.74 18.0 368 128 44.9 0.83 19 3.77 18.1 371 129 43.5 0.58 16 3.77 18.1 376 135 47.1 0.60 16 3.87 18.5 388 140 48.6 0.63 16 3.90 18.6 392 141 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 40.8 44.7 38.4 39.8 43.6 0.61 0.42 0.75 0.63 0.43 16 12 19 16 12 3.44 3.55 3.54 3.62 3.74 16.5 16.9 17.1 17.4 17.9 310 327 328 353 373 117 128 115 123 134 44.2 48.4 41.6 43.1 47.2 0.63 0.44 0.78 0.65 0.45 16 12 19 16 12 3.52 3.64 3.63 3.71 3.83 16.9 17.3 17.5 17.8 18.4 319 337 338 364 384 120 132 119 127 138 45.5 49.9 42.8 44.4 48.7 0.66 0.46 0.82 0.68 0.47 15 12 18 15 12 3.55 3.67 3.66 3.74 3.87 17.0 17.5 17.6 18.0 18.5 323 341 341 367 388 122 133 120 128 140 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 MODEL: *SXC160481B* / CA*F496**6** + TXV / MBVC2000**-1** 46.7 0.37 11 3.90 18.6 393 144 50.6 0.38 11 4.00 19.1 405 149 52.1 0.40 11 4.03 19.3 409 150 71 - EXPANDED PERFORMANCE DATA 37.1 0.88 22 3.72 18.1 373 122 40.2 0.92 21 3.82 18.6 384 126 41.4 0.96 20 3.85 18.7 388 127 59 36.5 0.78 19 3.69 18.0 369 121 39.5 0.81 18 3.78 18.4 380 125 40.7 0.85 18 3.82 18.6 384 126 38.2 0.79 20 3.80 18.5 401 130 41.4 0.82 20 3.90 19.0 413 134 42.6 0.86 19 3.94 19.1 418 135 63 37.8 0.65 16 3.77 18.4 397 129 41.0 0.67 16 3.87 18.8 409 133 42.2 0.71 15 3.90 19.0 413 134 41.3 0.60 16 3.93 19.1 423 142 44.8 0.62 16 4.03 19.5 437 146 46.1 0.65 15 4.07 19.7 441 148 67 41.4 0.45 12 3.90 18.9 419 140 44.9 0.47 12 4.00 19.4 432 145 46.2 0.49 12 4.03 19.5 437 146 105 34.4 0.89 20 3.85 19.1 412 126 37.2 0.93 20 3.95 19.5 424 130 38.3 0.97 19 3.99 19.7 429 132 59 33.8 0.78 17 3.82 18.9 408 125 36.6 0.81 17 3.92 19.4 420 129 37.7 0.85 16 3.95 19.5 424 130 35.4 0.80 19 3.94 19.5 443 134 38.3 0.83 18 4.04 20.0 457 139 39.5 0.87 17 4.08 20.1 461 140 63 35.0 0.66 15 3.90 19.3 439 133 37.9 0.68 15 4.01 19.8 452 137 39.1 0.71 14 4.04 20.0 457 139 38.3 0.60 15 4.07 20.0 468 147 41.5 0.63 15 4.18 20.5 482 151 42.7 0.66 14 4.21 20.7 487 153 67 38.4 0.45 11 4.04 19.9 463 145 41.6 0.47 11 4.14 20.4 478 150 42.8 0.49 11 4.18 20.5 482 151 41.1 0.39 10 4.21 20.7 488 156 44.5 0.40 10 4.32 21.2 503 161 45.9 0.42 10 4.36 21.4 508 163 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 44.4 0.39 11 4.06 19.7 442 151 48.1 0.40 11 4.17 20.2 455 156 49.5 0.42 11 4.21 20.3 460 157 71 - 115 COOLING OPERATION COOLING PERFORMANCE DATA *SXC160481B*-HIGH STAGE 1800 1600 1400 1800 1600 1400 Airflow 67 46.6 0.65 20 3.14 15.0 262 119 50.5 0.67 20 3.22 15.4 270 122 52.0 0.71 19 3.25 15.5 272 123 46.4 0.78 24 3.17 15.1 264 120 50.3 0.81 23 3.25 15.5 272 123 51.8 0.85 22 3.27 15.6 275 125 MBh 43.5 44.3 S/T 0.89 0.86 Delta T 25 25 KW 3.01 3.07 AMPS 14.5 14.7 HI PR 233 250 LO PR 103 110 MBh 47.1 48.0 S/T 0.93 0.89 Delta T 25 25 KW 3.08 3.15 AMPS 14.8 15.1 HI PR 240 258 LO PR 106 113 MBh 48.5 49.4 S/T 0.97 0.94 Delta T 24.07 24 KW 3.11 3.17 AMPS 14.9 15.2 HI PR 242 261 LO PR 107 114 59 42.7 0.85 24 2.98 14.4 230 102 46.3 0.88 24 3.06 14.7 237 105 47.7 0.93 23 3.08 14.8 240 106 63 43.6 0.80 23 3.05 14.6 248 109 47.3 0.83 23 3.12 15.0 255 112 48.7 0.87 22 3.15 15.1 258 113 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 49.5 0.63 21 3.27 15.6 276 128 53.6 0.65 20 3.35 16.0 284 131 55.2 0.69 19 3.38 16.1 287 133 71 49.9 0.49 16 3.24 15.5 273 126 54.0 0.50 16 3.33 15.9 281 130 55.6 0.53 15 3.35 16.0 284 131 42.5 0.93 26 3.24 15.4 261 109 46.0 0.96 25 3.32 15.8 269 112 47.4 1.00 24 3.35 15.9 272 113 59 41.7 0.88 24 3.21 15.3 258 108 45.2 0.92 24 3.29 15.7 266 111 46.6 0.96 23 3.32 15.8 269 112 43.3 0.89 25 3.31 15.7 281 116 46.9 0.93 25 3.39 16.1 289 119 48.3 0.97 24 3.42 16.2 292 121 63 42.6 0.83 23 3.28 15.6 278 115 46.2 0.86 23 3.37 16.0 287 118 47.6 0.90 22 3.39 16.1 289 119 75 45.3 0.81 24 3.42 16.2 296 127 49.1 0.84 24 3.51 16.5 306 130 50.6 0.88 23 3.53 16.7 309 132 67 45.6 0.67 20 3.39 16.0 294 125 49.4 0.70 20 3.48 16.4 303 129 50.8 0.73 19 3.51 16.5 306 130 48.4 0.65 21 3.53 16.7 309 135 52.4 0.68 20 3.62 17.1 319 139 54.0 0.71 20 3.65 17.2 322 140 71 48.7 0.50 16 3.50 16.5 306 133 52.8 0.52 16 3.59 16.9 316 138 54.3 0.55 15 3.62 17.1 319 139 41.4 0.95 26 3.45 16.5 297 113 44.9 0.98 25 3.53 16.9 306 117 46.2 1.00 24 3.56 17.0 309 118 59 40.7 0.91 24 3.42 16.4 294 112 44.1 0.94 24 3.51 16.8 303 116 45.5 1.00 23 3.53 16.9 306 117 42.2 0.92 25 3.52 16.9 319 120 45.8 0.95 25 3.61 17.3 329 124 47.1 1.00 24 3.64 17.4 332 125 44.2 0.83 24 3.64 17.3 337 132 47.9 0.86 24 3.73 17.8 348 136 49.4 0.90 23 3.76 17.9 351 137 47.2 0.67 21 3.76 17.9 352 140 51.1 0.70 20 3.86 18.3 363 144 52.7 0.73 20 3.89 18.5 366 146 40.4 0.98 26 3.63 17.5 338 119 43.8 1.00 25 3.72 17.9 348 123 45.1 1.00 23 3.75 18.0 352 124 41.2 0.95 26 3.71 17.8 364 127 44.7 0.98 25 3.81 18.3 375 130 46.0 1.00 23 3.84 18.4 379 132 43.2 0.85 24 3.83 18.3 384 138 46.8 0.89 24 3.93 18.8 396 142 48.2 0.93 23 3.97 18.9 400 144 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 41.6 44.5 47.5 39.7 40.6 43.4 0.85 0.69 0.52 0.93 0.88 0.71 23 20 16 24 23 20 3.49 3.61 3.73 3.60 3.68 3.80 16.7 17.2 17.7 17.3 17.7 18.2 316 334 348 335 360 380 119 130 139 118 125 137 45.1 48.2 51.5 43.1 44.0 47.0 0.88 0.72 0.54 0.97 0.91 0.74 23 20 16 24 23 20 3.58 3.70 3.83 3.69 3.77 3.90 17.1 17.6 18.2 17.8 18.1 18.7 326 344 359 345 371 392 123 134 143 121 129 141 46.4 49.6 53.0 44.3 45.3 48.4 0.92 0.75 0.56 1.00 0.95 0.78 22 19 15 23 22 19 3.61 3.73 3.86 3.72 3.81 3.93 17.3 17.8 18.3 17.9 18.3 18.8 329 348 363 348 375 396 124 136 144 123 130 142 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 MODEL: *SXC160481B* / CA*F496**6** + TXV / MBVC2000**-1** 46.0 0.69 21 3.96 18.9 401 147 49.9 0.72 21 4.07 19.4 413 152 51.4 0.75 20 4.10 19.6 417 153 71 46.4 0.53 16 3.93 18.8 397 146 50.2 0.55 16 4.03 19.3 409 150 51.8 0.58 15 4.07 19.4 413 152 EXPANDED PERFORMANCE DATA 38.4 1.00 25 3.78 18.4 380 125 41.6 1.00 24 3.88 18.9 392 129 42.9 1.00 22 3.92 19.0 396 130 59 37.8 0.97 24 3.75 18.3 376 123 40.9 1.00 24 3.85 18.7 388 127 42.1 1.00 22 3.88 18.9 392 129 39.2 0.98 25 3.87 18.8 409 133 42.4 1.00 24 3.97 19.3 422 137 43.7 1.00 22 4.00 19.4 426 138 63 38.6 0.91 23 3.84 18.7 405 131 41.8 0.94 23 3.94 19.1 418 135 43.0 1.00 22 3.97 19.3 422 137 41.0 0.89 24 4.00 19.4 432 145 44.4 0.92 23 4.10 19.8 445 149 45.8 0.96 23 4.14 20.0 450 151 67 41.2 0.74 20 3.96 19.2 428 143 44.7 0.77 20 4.07 19.7 441 148 46.0 0.81 19 4.10 19.8 445 149 105 35.6 1.00 23 3.92 19.4 420 129 38.5 1.00 22 4.02 19.9 433 133 39.7 1.00 20 4.05 20.0 437 134 59 35.0 0.98 22 3.88 19.2 416 128 37.9 1.00 22 3.99 19.7 429 132 39.0 1.00 20 4.02 19.9 433 133 36.3 0.99 24 4.01 19.8 452 137 39.3 1.00 23 4.11 20.3 466 141 40.5 1.00 21 4.15 20.4 471 143 63 35.7 0.92 22 3.97 19.6 448 136 38.7 0.95 21 4.08 20.1 461 140 39.9 1.00 20 4.11 20.3 466 141 38.0 0.89 22 4.14 20.4 477 150 41.2 0.93 22 4.25 20.9 492 154 42.4 0.97 21 4.29 21.0 497 156 67 38.2 0.75 19 4.11 20.2 473 148 41.4 0.77 18 4.21 20.7 487 153 42.6 0.81 18 4.25 20.9 492 154 40.5 0.72 19 4.28 21.0 498 159 43.9 0.75 19 4.40 21.6 513 164 45.2 0.79 18 4.44 21.8 518 166 71 40.8 0.56 15 4.25 20.9 493 158 44.2 0.58 15 4.36 21.4 508 163 45.5 0.61 14 4.40 21.6 513 164 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 43.7 0.72 21 4.13 20.0 451 154 47.4 0.75 20 4.24 20.5 465 159 48.8 0.78 19 4.28 20.7 469 161 71 44.1 0.55 16 4.10 19.8 446 153 47.7 0.57 16 4.21 20.3 460 157 49.2 0.60 15 4.24 20.5 465 159 115 COOLING OPERATION COOLING PERFORMANCE DATA *SXC160481B*-HIGH STAGE 35 36 2025 1800 1575 2025 1800 1575 Airflow 59 50.1 0.70 21 3.87 13.9 242 115 54.2 0.73 20 3.91 14.0 245 116 55.9 0.77 19 3.94 14.2 247 118 50.9 0.80 24 3.87 13.9 242 115 55.1 0.83 23 3.91 14.0 245 116 56.8 0.87 22 3.94 14.2 247 118 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 52.4 0.72 22 3.96 14.3 260 119 56.8 0.74 22 3.99 14.4 263 120 58.5 0.78 21 4.02 14.5 266 121 63 51.9 0.59 18 3.96 14.3 260 119 56.2 0.61 18 3.99 14.4 263 120 57.9 0.64 17 4.02 14.5 266 121 56.7 0.54 18 4.08 14.7 264 130 61.5 0.56 18 4.12 14.9 267 131 63.3 0.59 17 4.15 15.0 269 132 67 56.8 0.41 14 4.08 14.7 264 130 61.6 0.42 13 4.12 14.9 267 131 63.4 0.44 13 4.15 15.0 269 132 60.9 0.35 12 4.22 15.3 270 138 66.0 0.36 12 4.25 15.5 273 140 67.9 0.38 12 4.29 15.6 275 141 71 49.7 0.83 24 4.18 15.1 266 119 53.9 0.86 24 4.21 15.2 269 120 55.5 0.90 23 4.25 15.4 271 121 59 48.9 0.73 21 4.18 15.1 266 119 53.0 0.76 20 4.21 15.2 269 120 54.6 0.79 20 4.25 15.4 271 121 51.2 0.74 22 4.27 15.5 286 122 55.5 0.77 22 4.30 15.6 289 124 57.1 0.81 21 4.34 15.8 292 125 63 50.7 0.61 18 4.27 15.5 286 122 54.9 0.63 18 4.30 15.6 289 124 56.5 0.66 17 4.34 15.8 292 125 75 55.4 0.56 18 4.41 16.0 290 134 60.0 0.58 18 4.44 16.1 293 135 61.8 0.61 17 4.48 16.3 296 136 67 55.5 0.42 14 4.41 16.0 290 134 60.1 0.44 13 4.44 16.1 293 135 62.0 0.46 13 4.48 16.3 296 136 59.5 0.36 13 4.55 16.6 296 142 64.4 0.37 12 4.59 16.8 299 144 66.4 0.39 12 4.63 16.9 302 145 71 48.5 0.85 24 4.44 16.4 311 123 52.6 0.88 24 4.48 16.6 314 124 54.2 0.93 23 4.52 16.8 318 125 59 47.7 0.75 21 4.44 16.4 311 123 51.7 0.78 20 4.48 16.6 314 124 53.3 0.81 20 4.52 16.8 318 125 50.0 0.76 22 4.54 16.9 335 126 54.1 0.79 22 4.58 17.0 338 128 55.8 0.83 21 4.62 17.2 342 129 54.1 0.58 18 4.69 17.4 340 138 58.6 0.60 18 4.73 17.6 343 139 60.4 0.63 17 4.77 17.8 346 141 58.1 0.37 13 4.85 18.1 347 147 62.9 0.38 12 4.89 18.3 350 149 64.8 0.40 12 4.93 18.5 354 150 47.3 0.88 24 4.68 17.6 355 126 51.3 0.91 24 4.72 17.8 358 127 52.8 0.95 23 4.76 18.0 362 128 48.8 0.79 22 4.78 18.1 381 130 52.8 0.81 22 4.82 18.2 385 131 54.4 0.85 21 4.86 18.4 389 132 52.8 0.59 18 4.94 18.7 387 142 57.2 0.62 18 4.98 18.9 391 143 58.9 0.65 17 5.03 19.0 395 145 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 49.5 54.2 46.6 48.3 52.9 0.63 0.43 0.77 0.65 0.45 18 14 21 18 14 4.54 4.69 4.68 4.78 4.94 16.9 17.4 17.6 18.1 18.7 335 340 355 381 387 126 138 126 130 142 53.6 58.7 50.4 52.3 57.3 0.65 0.45 0.80 0.67 0.46 18 13 21 18 14 4.58 4.73 4.72 4.82 4.98 17.0 17.6 17.8 18.2 18.9 338 343 358 385 391 128 139 127 131 143 55.2 60.5 52.0 53.9 59.0 0.68 0.47 0.84 0.70 0.49 17 13 20 17 13 4.62 4.77 4.76 4.86 5.03 17.2 17.8 18.0 18.4 19.0 342 346 362 389 395 129 141 128 132 145 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 56.6 0.38 13 5.11 19.4 395 151 61.4 0.40 12 5.15 19.6 399 153 63.2 0.42 12 5.20 19.8 403 154 71 45.0 0.91 24 4.88 20.6 399 128 48.7 0.95 24 4.92 20.8 403 130 50.2 0.99 23 4.96 21.0 407 131 59 44.2 0.80 21 4.88 20.6 399 128 47.9 0.83 20 4.92 20.8 403 130 49.4 0.87 20 4.96 21.0 407 131 46.3 0.82 22 4.99 21.1 429 132 50.2 0.85 22 5.03 21.4 433 134 51.7 0.89 21 5.07 21.6 438 135 63 45.8 0.67 18 4.99 21.1 429 132 49.7 0.69 18 5.03 21.4 433 134 51.2 0.73 17 5.07 21.6 438 135 50.1 0.62 18 5.16 21.9 435 145 54.3 0.64 18 5.20 22.1 439 146 55.9 0.67 17 5.24 22.3 444 148 67 50.2 0.46 14 5.16 21.9 435 145 54.4 0.48 13 5.20 22.1 439 146 56.1 0.50 13 5.24 22.3 444 148 105 41.7 0.92 22 5.05 21.8 461 132 45.1 0.95 22 5.09 22.0 466 133 46.5 1.00 21 5.14 22.2 470 134 59 41.0 0.81 19 5.05 21.8 461 132 44.4 0.84 19 5.09 22.0 466 133 45.7 0.88 18 5.14 22.2 470 134 42.9 0.82 21 5.17 22.3 496 136 46.5 0.85 20 5.21 22.6 501 137 47.9 0.89 19 5.25 22.8 506 138 63 42.5 0.68 17 5.17 22.3 496 136 46.0 0.70 16 5.21 22.6 501 137 47.4 0.73 16 5.25 22.8 506 138 46.4 0.62 17 5.34 23.1 503 148 50.3 0.65 17 5.39 23.4 508 150 51.8 0.68 16 5.43 23.6 513 151 67 46.5 0.47 13 5.34 23.1 503 148 50.4 0.49 12 5.39 23.4 508 150 51.9 0.51 12 5.43 23.6 513 151 49.8 0.40 12 5.52 24.0 514 158 54.0 0.42 11 5.57 24.3 519 159 55.6 0.44 11 5.62 24.5 524 161 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 53.8 0.40 12 5.33 22.7 445 154 58.3 0.41 12 5.38 23.0 449 156 60.0 0.43 12 5.42 23.2 454 157 71 - 115 COOLING OPERATION MODEL: *SXC160601A* / CA*F4961*6** + TXV / MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA COOLING PERFORMANCE DATA *SXC160601A*-HIGH STAGE 2025 1800 1575 2025 1800 1575 Airflow 59 51.8 0.88 27 3.87 13.9 242 115 56.1 0.91 26 3.91 14.0 245 116 57.8 0.95 25 3.94 14.2 247 118 52.7 0.92 28 3.87 13.9 242 115 57.1 0.95 28 3.91 14.0 245 116 58.8 1.00 27 3.94 14.2 247 118 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 53.7 0.89 28 3.96 14.3 260 119 58.2 0.92 27 3.99 14.4 263 120 60.0 0.97 26 4.02 14.5 266 121 63 52.9 0.82 25 3.96 14.3 260 119 57.4 0.85 25 3.99 14.4 263 120 59.1 0.90 24 4.02 14.5 266 121 56.3 0.80 26 4.08 14.7 264 130 61.0 0.83 26 4.12 14.9 267 131 62.8 0.87 25 4.15 15.0 269 132 67 56.6 0.67 22 4.08 14.7 264 130 61.3 0.70 22 4.12 14.9 267 131 63.1 0.73 21 4.15 15.0 269 132 60.0 0.65 23 4.22 15.3 270 138 65.0 0.67 22 4.25 15.5 273 140 67.0 0.71 22 4.29 15.6 275 141 71 60.5 0.50 18 4.22 15.3 270 138 65.5 0.52 17 4.25 15.5 273 140 67.5 0.54 17 4.29 15.6 275 141 51.5 0.95 29 4.18 15.1 266 119 55.8 0.99 28 4.21 15.2 269 120 57.5 1.00 26 4.25 15.4 271 121 59 50.6 0.91 27 4.18 15.1 266 119 54.8 0.94 26 4.21 15.2 269 120 56.5 1.00 26 4.25 15.4 271 121 52.5 0.92 28 4.27 15.5 286 122 56.9 0.95 28 4.30 15.6 289 124 58.6 1.00 27 4.34 15.8 292 125 63 51.7 0.85 26 4.27 15.5 286 122 56.0 0.88 25 4.30 15.6 289 124 57.7 0.93 24 4.34 15.8 292 125 75 55.0 0.83 27 4.41 16.0 290 134 59.6 0.86 26 4.44 16.1 293 135 61.3 0.90 25 4.48 16.3 296 136 67 55.2 0.69 22 4.41 16.0 290 134 59.9 0.72 22 4.44 16.1 293 135 61.6 0.76 21 4.48 16.3 296 136 58.6 0.67 23 4.55 16.6 296 142 63.5 0.70 23 4.59 16.8 299 144 65.4 0.73 22 4.63 16.9 302 145 71 59.1 0.52 18 4.55 16.6 296 142 64.0 0.54 18 4.59 16.8 299 144 65.9 0.56 17 4.63 16.9 302 145 50.3 0.98 29 4.44 16.4 311 123 54.5 1.00 28 4.48 16.6 314 124 56.1 1.00 25 4.52 16.8 318 125 59 49.4 0.93 27 4.44 16.4 311 123 53.5 0.97 26 4.48 16.6 314 124 55.1 1.00 25 4.52 16.8 318 125 51.2 0.94 28 4.54 16.9 335 126 55.5 0.98 28 4.58 17.0 338 128 57.2 1.00 26 4.62 17.2 342 129 53.7 0.85 27 4.69 17.4 340 138 58.1 0.88 26 4.73 17.6 343 139 59.9 0.93 25 4.77 17.8 346 141 57.2 0.69 23 4.85 18.1 347 147 62.0 0.72 23 4.89 18.3 350 149 63.9 0.75 22 4.93 18.5 354 150 49.0 1.00 29 4.68 17.6 355 126 53.1 1.00 27 4.72 17.8 358 127 54.7 1.00 25 4.76 18.0 362 128 50.0 0.97 28 4.78 18.1 381 130 54.2 1.00 28 4.82 18.2 385 131 55.8 1.00 25 4.86 18.4 389 132 52.3 0.88 27 4.94 18.7 387 142 56.7 0.91 26 4.98 18.9 391 143 58.4 0.96 25 5.03 19.0 395 145 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 50.5 53.9 57.6 48.2 49.2 52.6 0.88 0.71 0.53 0.96 0.90 0.74 26 22 18 27 26 23 4.54 4.69 4.85 4.68 4.78 4.94 16.9 17.4 18.1 17.6 18.1 18.7 335 340 347 355 381 387 126 138 147 126 130 142 54.7 58.4 62.5 52.2 53.4 57.0 0.91 0.74 0.55 1.00 0.94 0.76 25 22 18 27 26 22 4.58 4.73 4.89 4.72 4.82 4.98 17.0 17.6 18.3 17.8 18.2 18.9 338 343 350 358 385 391 128 139 149 127 131 143 56.3 60.2 64.3 53.8 55.0 58.7 0.95 0.77 0.58 1.00 1.00 0.80 24 21 17 24 25 21 4.62 4.77 4.93 4.76 4.86 5.03 17.2 17.8 18.5 18.0 18.4 19.0 342 346 354 362 389 395 129 141 150 128 132 145 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 55.8 0.71 23 5.11 19.4 395 151 60.5 0.74 23 5.15 19.6 399 153 62.3 0.78 22 5.20 19.8 403 154 71 56.2 0.55 18 5.11 19.4 395 151 60.9 0.57 18 5.15 19.6 399 153 62.8 0.60 17 5.20 19.8 403 154 46.6 1.00 27 4.88 20.6 399 128 50.5 1.00 26 4.92 20.8 403 130 52.0 1.00 24 4.96 21.0 407 131 59 45.8 1.00 27 4.88 20.6 399 128 49.6 1.00 25 4.92 20.8 403 130 51.1 1.00 23 4.96 21.0 407 131 47.5 1.00 28 4.99 21.1 429 132 51.4 1.00 26 5.03 21.4 433 134 53.0 1.00 24 5.07 21.6 438 135 63 46.8 0.94 26 4.99 21.1 429 132 50.7 0.97 25 5.03 21.4 433 134 52.2 1.00 24 5.07 21.6 438 135 49.7 0.91 26 5.16 21.9 435 145 53.9 0.95 26 5.20 22.1 439 146 55.5 0.99 25 5.24 22.3 444 148 67 50.0 0.76 22 5.16 21.9 435 145 54.2 0.79 22 5.20 22.1 439 146 55.8 0.83 21 5.24 22.3 444 148 105 43.1 1.00 25 5.05 21.8 461 132 46.7 1.00 24 5.09 22.0 466 133 48.2 1.00 22 5.14 22.2 470 134 59 42.4 1.01 25 5.05 21.8 461 132 45.9 1.00 23 5.09 22.0 466 133 47.3 1.00 21 5.14 22.2 470 134 44.0 1.00 26 5.17 22.3 496 136 47.7 1.00 24 5.21 22.6 501 137 49.1 1.00 22 5.25 22.8 506 138 63 43.3 0.95 24 5.17 22.3 496 136 46.9 0.98 24 5.21 22.6 501 137 48.4 1.00 22 5.25 22.8 506 138 46.1 0.92 25 5.34 23.1 503 148 49.9 0.95 24 5.39 23.4 508 150 51.4 1.00 23 5.43 23.6 513 151 67 46.3 0.77 21 5.34 23.1 503 148 50.2 0.80 20 5.39 23.4 508 150 51.7 0.84 20 5.43 23.6 513 151 49.1 0.75 21 5.52 24.0 514 158 53.2 0.77 21 5.57 24.3 519 159 54.8 0.81 20 5.62 24.5 524 161 71 49.5 0.58 17 5.52 24.0 514 158 53.6 0.60 16 5.57 24.3 519 159 55.2 0.63 16 5.62 24.5 524 161 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 53.1 0.74 23 5.33 22.7 445 154 57.5 0.77 23 5.38 23.0 449 156 59.2 0.81 22 5.42 23.2 454 157 71 53.4 0.57 18 5.33 22.7 445 154 57.9 0.59 17 5.38 23.0 449 156 59.6 0.62 17 5.42 23.2 454 157 115 COOLING OPERATION MODEL: *SXC160601A* / CA*F4961*6** + TXV / MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA COOLING PERFORMANCE DATA *SXC160601A*-HIGH STAGE 37 38 2025 1800 1575 2025 1800 1575 Airflow 59 50.1 0.68 20 3.45 13.6 222 100 54.2 0.71 20 3.54 13.9 229 103 55.9 0.74 19 3.57 14.1 231 104 50.9 0.78 23 3.48 13.7 224 101 55.1 0.81 23 3.57 14.1 231 104 56.8 0.84 22 3.60 14.2 233 105 MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR 52.4 0.69 21 3.56 14.0 241 108 56.8 0.72 21 3.65 14.4 248 111 58.5 0.76 20 3.68 14.6 251 112 63 51.9 0.57 17 3.53 13.9 239 106 56.2 0.59 17 3.62 14.3 246 110 57.9 0.62 16 3.65 14.4 248 111 56.7 0.53 17 3.68 14.5 254 117 61.5 0.55 17 3.78 14.9 262 121 63.3 0.57 16 3.81 15.0 265 122 67 56.8 0.40 13 3.65 14.4 252 116 61.6 0.41 13 3.74 14.8 260 120 63.4 0.43 12 3.77 14.9 262 121 60.9 0.34 12 3.80 15.0 265 125 66.0 0.35 12 3.90 15.5 274 129 67.9 0.37 11 3.94 15.6 276 130 71 49.7 0.81 23 3.77 14.8 251 107 53.9 0.84 23 3.87 15.3 259 110 55.5 0.88 22 3.90 15.4 262 111 59 48.9 0.71 20 3.73 14.7 249 106 53.0 0.73 20 3.83 15.1 256 109 54.6 0.77 19 3.86 15.2 259 110 51.2 0.72 22 3.85 15.2 270 114 55.5 0.75 21 3.95 15.6 279 117 57.1 0.78 20 3.99 15.8 282 118 63 50.7 0.59 17 3.82 15.0 268 112 54.9 0.61 17 3.92 15.5 276 116 56.5 0.64 17 3.95 15.6 279 117 75 55.4 0.55 18 3.98 15.7 286 124 60.0 0.57 17 4.09 16.2 294 128 61.8 0.59 17 4.12 16.3 297 129 67 55.5 0.41 13 3.95 15.6 283 123 60.1 0.43 13 4.05 16.0 291 127 62.0 0.45 13 4.09 16.2 294 128 59.5 0.35 12 4.12 16.3 298 132 64.4 0.36 12 4.23 16.8 307 136 66.4 0.38 11 4.27 16.9 310 138 71 48.5 0.83 23 4.02 16.1 286 111 52.6 0.86 23 4.12 16.6 295 114 54.2 0.90 22 4.16 16.8 298 116 59 47.7 0.73 20 3.98 16.0 283 110 51.7 0.75 20 4.09 16.5 292 113 53.3 0.79 19 4.12 16.6 295 114 50.0 0.74 22 4.11 16.5 308 118 54.1 0.77 21 4.22 17.0 317 122 55.8 0.80 20 4.26 17.2 320 123 54.1 0.56 18 4.25 17.1 325 129 58.6 0.58 17 4.36 17.6 335 133 60.4 0.61 17 4.40 17.8 338 134 58.1 0.36 12 4.40 17.8 339 137 62.9 0.37 12 4.52 18.3 349 142 64.8 0.39 12 4.56 18.5 353 143 47.3 0.85 24 4.24 17.3 326 117 51.3 0.88 23 4.35 17.8 336 120 52.8 0.93 22 4.39 18.0 339 121 48.8 0.76 22 4.34 17.7 350 124 52.8 0.79 21 4.45 18.2 361 128 54.4 0.83 20 4.49 18.4 365 129 52.8 0.58 18 4.49 18.3 370 135 57.2 0.60 17 4.61 18.9 381 140 58.9 0.63 17 4.65 19.0 385 141 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 49.5 54.2 46.6 48.3 52.9 0.61 0.42 0.75 0.63 0.43 18 13 20 18 13 4.07 4.21 4.20 4.30 4.45 16.4 16.9 17.1 17.5 18.1 304 321 322 347 366 117 128 115 123 134 53.6 58.7 50.4 52.3 57.3 0.63 0.44 0.78 0.65 0.45 17 13 20 17 13 4.18 4.33 4.31 4.41 4.57 16.9 17.4 17.6 18.1 18.7 314 331 332 357 377 120 132 119 127 138 55.2 60.5 52.0 53.9 59.0 0.66 0.46 0.82 0.68 0.47 17 13 19 17 13 4.22 4.36 4.35 4.45 4.61 17.0 17.6 17.8 18.2 18.9 317 335 336 361 381 122 133 120 128 140 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 56.6 0.37 12 4.64 19.0 386 144 61.4 0.38 12 4.77 19.6 398 149 63.2 0.40 12 4.81 19.8 402 150 71 45.0 0.88 23 4.43 18.4 366 122 48.7 0.92 23 4.55 19.0 378 126 50.2 0.96 22 4.59 19.1 381 127 59 44.2 0.78 20 4.39 18.2 363 121 47.9 0.81 20 4.51 18.8 374 125 49.4 0.85 19 4.55 19.0 377 126 46.3 0.79 21 4.53 18.9 394 130 50.2 0.82 21 4.65 19.4 406 134 51.7 0.86 20 4.70 19.6 410 135 63 45.8 0.65 17 4.49 18.7 390 129 49.7 0.67 17 4.61 19.2 402 133 51.2 0.71 16 4.65 19.4 406 134 50.1 0.60 18 4.69 19.5 416 142 54.3 0.62 17 4.82 20.1 429 146 55.9 0.65 17 4.86 20.3 433 148 67 50.2 0.45 13 4.65 19.3 412 140 54.4 0.47 13 4.77 19.9 425 145 56.1 0.49 12 4.82 20.1 429 146 105 41.7 0.89 22 4.59 19.5 405 126 45.1 0.93 21 4.71 20.1 417 130 46.5 0.97 20 4.76 20.3 421 132 59 41.0 0.78 19 4.55 19.4 401 125 44.4 0.81 18 4.67 19.9 413 129 45.7 0.85 18 4.71 20.1 417 130 42.9 0.80 20 4.70 20.0 435 134 46.5 0.83 20 4.83 20.6 449 139 47.9 0.87 19 4.87 20.8 453 140 63 42.5 0.66 16 4.66 19.8 431 133 46.0 0.68 16 4.78 20.4 444 137 47.4 0.71 15 4.83 20.6 449 139 46.4 0.60 16 4.86 20.7 460 147 50.3 0.63 16 5.00 21.3 474 151 51.8 0.66 15 5.04 21.5 479 153 67 46.5 0.45 12 4.82 20.5 455 145 50.4 0.47 12 4.95 21.1 469 150 51.9 0.49 12 4.99 21.3 474 151 49.8 0.39 11 5.03 21.5 480 156 54.0 0.40 11 5.17 22.2 494 161 55.6 0.42 11 5.22 22.4 499 163 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 53.8 0.39 12 4.85 20.3 434 151 58.3 0.40 12 4.99 20.9 447 156 60.0 0.42 11 5.03 21.1 452 157 71 - 115 COOLING OPERATION MODEL: *SXC160601 B*/CA*F496*6** +TXV/MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA COOLING PERFORMANCE DATA A/DSXC160601B*-HIGH STAGE 2025 1800 1575 2025 1800 1575 Airflow 59 51.8 0.85 26 3.51 13.8 226 102 56.1 0.88 25 3.60 14.2 233 105 57.8 0.93 24 3.63 14.3 236 106 52.7 0.89 27 3.54 13.9 228 103 57.1 0.93 27 3.63 14.3 236 106 58.8 0.97 26 3.66 14.5 238 107 MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR MBh S/T DT KW AMPS HI PR LO PR 53.7 0.86 27 3.62 14.3 246 110 58.2 0.89 27 3.72 14.7 253 113 60.0 0.94 26 3.75 14.8 256 114 243 109 57.4 0.83 24 3.68 14.6 251 112 59.1 0.87 23 3.72 14.7 253 113 63 52.9 0.80 25 3.59 14.2 56.3 0.78 26 3.74 14.8 260 120 61.0 0.81 25 3.84 15.2 268 123 62.8 0.85 24 3.87 15.3 270 125 257 119 61.3 0.67 21 3.81 15.1 265 122 63.1 0.71 20 3.84 15.2 268 123 67 56.6 0.65 21 3.71 14.6 60.0 0.63 22 3.87 15.3 271 128 65.0 0.65 22 3.97 15.8 279 131 67.0 0.69 21 4.01 15.9 282 133 268 126 65.5 0.50 17 3.94 15.6 276 130 67.5 0.53 16 3.97 15.8 279 131 71 60.5 0.49 17 3.84 15.2 51.5 0.93 28 3.83 15.1 256 109 55.8 0.96 27 3.93 15.5 264 112 57.5 1.00 26 3.97 15.7 267 113 254 108 54.8 0.92 26 3.90 15.4 262 111 56.5 0.96 25 3.93 15.5 264 112 59 50.6 0.88 26 3.80 15.0 52.5 0.89 27 3.92 15.5 276 116 56.9 0.93 27 4.02 15.9 284 119 58.6 0.97 26 4.06 16.1 287 121 273 115 56.0 0.86 25 3.99 15.8 282 118 57.7 0.90 24 4.02 15.9 284 119 63 51.7 0.83 25 3.88 15.3 75 55.0 0.81 26 4.05 16.0 291 127 59.6 0.84 25 4.16 16.5 300 130 61.3 0.88 24 4.20 16.6 303 132 288 125 59.9 0.70 21 4.12 16.3 297 129 61.6 0.73 21 4.16 16.5 300 130 67 55.2 0.67 22 4.02 15.9 58.6 0.65 22 4.19 16.6 304 135 63.5 0.68 22 4.30 17.1 313 139 65.4 0.71 21 4.34 17.3 316 140 301 133 64.0 0.52 17 4.27 16.9 310 138 65.9 0.55 16 4.30 17.1 313 139 71 59.1 0.50 17 4.16 16.5 50.3 0.95 28 4.09 16.4 292 113 54.5 0.98 27 4.20 16.9 301 117 56.1 1.00 25 4.23 17.1 304 118 289 112 53.5 0.94 26 4.16 16.8 298 116 55.1 1.00 25 4.20 16.9 301 117 59 49.4 0.91 26 4.05 16.3 51.2 0.92 27 4.18 16.9 314 120 55.5 0.95 27 4.29 17.3 323 124 57.2 1.00 26 4.33 17.5 327 125 311 119 54.7 0.88 25 4.26 17.2 320 123 56.3 0.92 24 4.29 17.3 323 124 53.7 0.83 26 4.33 17.4 331 132 58.1 0.86 25 4.44 17.9 342 136 59.9 0.90 24 4.48 18.1 345 137 328 130 58.4 0.72 21 4.40 17.8 338 134 60.2 0.75 21 4.44 17.9 342 136 57.2 0.67 22 4.48 18.1 346 140 62.0 0.70 22 4.60 18.6 356 144 63.9 0.73 21 4.64 18.8 360 146 342 139 62.5 0.54 17 4.56 18.5 353 143 64.3 0.56 16 4.60 18.6 356 144 49.0 0.98 28 4.31 17.6 332 119 53.1 1.00 27 4.43 18.1 342 123 54.7 1.00 25 4.47 18.3 346 124 329 118 52.2 0.97 26 4.39 18.0 339 121 53.8 1.00 24 4.43 18.1 342 123 50.0 0.95 28 4.41 18.1 357 127 54.2 0.98 27 4.53 18.6 368 130 55.8 1.00 25 4.57 18.8 372 132 354 125 53.4 0.91 25 4.49 18.4 365 129 55.0 0.95 24 4.53 18.6 368 130 52.3 0.85 26 4.57 18.7 377 138 56.7 0.89 26 4.69 19.2 389 142 58.4 0.93 25 4.73 19.4 393 144 374 137 57.0 0.74 22 4.65 19.0 385 141 58.7 0.78 21 4.69 19.2 389 142 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 50.5 53.9 57.6 48.2 49.2 52.6 0.85 0.69 0.52 0.93 0.88 0.71 25 22 17 26 25 22 4.15 4.29 4.44 4.28 4.38 4.53 16.7 17.3 17.9 17.4 17.9 18.5 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 55.8 0.69 23 4.73 19.4 394 147 60.5 0.72 22 4.86 20.0 406 152 62.3 0.75 21 4.90 20.2 410 153 390 146 60.9 0.55 17 4.81 19.8 402 150 62.8 0.58 17 4.86 20.0 406 152 71 56.2 0.53 18 4.69 19.2 46.6 1.00 27 4.51 18.8 374 125 50.5 1.00 26 4.63 19.3 385 129 52.0 1.00 24 4.67 19.5 389 130 370 123 49.6 1.00 25 4.59 19.1 381 127 51.1 1.00 23 4.63 19.3 385 129 59 45.8 0.97 26 4.47 18.6 47.5 0.98 27 4.61 19.2 402 133 51.4 1.00 26 4.74 19.8 414 137 53.0 1.00 24 4.78 20.0 419 138 398 131 50.7 0.94 24 4.70 19.6 410 135 52.2 1.00 24 4.74 19.8 414 137 63 46.8 0.91 25 4.57 19.1 49.7 0.89 26 4.77 19.9 425 145 53.9 0.92 25 4.90 20.5 438 149 55.5 0.96 24 4.95 20.7 442 151 420 143 54.2 0.77 21 4.86 20.3 433 148 55.8 0.81 20 4.90 20.5 438 149 67 50.0 0.74 22 4.73 19.7 105 43.1 1.00 25 4.67 19.9 413 129 46.7 1.00 24 4.80 20.5 426 133 48.2 1.00 22 4.84 20.7 430 134 409 128 45.9 1.00 23 4.76 20.3 421 132 47.3 1.00 21 4.80 20.5 426 133 59 42.4 0.98 24 4.63 19.7 44.0 0.99 25 4.78 20.4 444 137 47.7 1.00 24 4.91 21.0 458 141 49.1 1.00 22 4.96 21.2 463 143 440 136 46.9 0.95 23 4.87 20.8 453 140 48.4 1.00 22 4.91 21.0 458 141 63 43.3 0.92 23 4.74 20.2 46.1 0.89 24 4.95 21.1 469 150 49.9 0.93 24 5.09 21.7 484 154 51.4 0.97 23 5.13 22.0 488 156 464 148 50.2 0.77 20 5.04 21.5 479 153 51.7 0.81 19 5.09 21.7 484 154 67 46.3 0.75 20 4.91 20.9 49.1 0.72 21 5.13 21.9 489 159 53.2 0.75 20 5.27 22.6 504 164 54.8 0.79 20 5.31 22.8 509 166 484 158 53.6 0.58 16 5.22 22.4 499 163 55.2 0.61 15 5.27 22.6 504 164 71 49.5 0.56 16 5.08 21.7 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 53.1 0.72 22 4.94 20.7 443 154 57.5 0.75 22 5.08 21.3 457 159 59.2 0.78 21 5.12 21.5 461 161 438 153 57.9 0.57 17 5.03 21.1 452 157 59.6 0.60 16 5.08 21.3 457 159 71 53.4 0.55 17 4.90 20.5 115 COOLING OPERATION MODEL: *SXC160601 B*/CA*F496*6** +TXV/MBVC2000**-1**, Design Subcooling @ AHRI 95°F Conditions, 5° - 7°F @ the Serv. Vlv. EXPANDED PERFORMANCE DATA COOLING PERFORMANCE DATA A/DSXC160601B*-HIGH STAGE 39 40 608 540 473 608 540 473 Airflow 59 15.5 0.66 20 1.03 4.1 194 98 16.7 0.68 19 1.05 4.2 200 101 17.2 0.71 19 1.06 4.2 202 102 15.7 0.75 23 1.04 4.1 196 99 17.0 0.77 22 1.06 4.2 202 102 17.5 0.81 22 1.07 4.3 204 103 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 16.2 0.67 21 1.06 4.2 211 106 17.5 0.69 21 1.09 4.3 217 109 18.1 0.73 20 1.09 4.4 220 110 63 16.0 0.55 17 1.05 4.2 209 105 17.4 0.57 17 1.08 4.3 215 108 17.9 0.60 16 1.09 4.3 217 109 17.5 0.50 17 1.09 4.4 223 115 19.0 0.52 17 1.12 4.5 230 119 19.5 0.55 16 1.13 4.5 232 120 67 17.6 0.38 13 1.08 4.3 220 114 19.0 0.39 13 1.11 4.4 227 118 19.6 0.41 12 1.12 4.5 229 119 18.8 0.32 12 1.13 4.5 232 123 20.4 0.34 12 1.16 4.6 239 127 21.0 0.35 11 1.17 4.7 242 128 71 15.4 0.77 23 1.12 4.4 220 105 16.6 0.80 23 1.15 4.6 227 108 17.1 0.84 22 1.16 4.6 229 109 59 15.1 0.68 20 1.11 4.4 218 104 16.4 0.70 20 1.14 4.5 224 107 16.8 0.74 19 1.15 4.6 227 108 15.8 0.69 21 1.14 4.5 237 112 17.1 0.72 21 1.17 4.7 244 115 17.6 0.75 20 1.18 4.7 246 116 63 15.6 0.57 17 1.13 4.5 234 111 17.0 0.59 17 1.16 4.6 241 114 17.5 0.62 16 1.17 4.7 244 115 75 17.1 0.52 17 1.18 4.7 250 122 18.5 0.54 17 1.21 4.8 258 126 19.1 0.57 16 1.22 4.9 260 127 67 17.1 0.39 13 1.17 4.6 247 121 18.6 0.41 13 1.20 4.8 255 124 19.1 0.43 12 1.21 4.8 258 126 18.4 0.34 12 1.22 4.9 261 130 19.9 0.35 12 1.25 5.0 269 134 20.5 0.37 11 1.26 5.0 271 135 71 15.0 0.79 23 1.19 4.8 250 109 16.2 0.82 23 1.22 4.9 258 112 16.7 0.86 22 1.23 5.0 260 114 59 14.7 0.70 20 1.18 4.8 248 108 16.0 0.72 20 1.21 4.9 255 111 16.4 0.76 19 1.22 4.9 258 112 15.4 0.71 21 1.22 4.9 269 116 16.7 0.73 21 1.25 5.0 277 120 17.2 0.77 20 1.26 5.1 280 121 16.7 0.54 17 1.26 5.1 284 127 18.1 0.56 17 1.29 5.2 293 131 18.6 0.58 16 1.30 5.3 296 132 17.9 0.35 12 1.30 5.3 296 135 19.4 0.36 12 1.33 5.4 306 139 20.0 0.38 11 1.34 5.4 309 141 14.6 0.82 23 1.25 5.1 285 115 15.8 0.85 23 1.29 5.3 294 118 16.3 0.89 22 1.30 5.3 297 119 15.1 0.73 21 1.28 5.2 306 122 16.3 0.76 21 1.31 5.4 316 126 16.8 0.80 20 1.33 5.4 319 127 16.3 0.55 18 1.32 5.4 324 133 17.7 0.57 17 1.36 5.6 334 137 18.2 0.60 17 1.37 5.6 337 139 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 15.3 16.7 14.4 14.9 16.3 0.58 0.40 0.72 0.60 0.42 17 13 20 17 13 1.21 1.25 1.24 1.27 1.31 4.9 5.0 5.1 5.2 5.4 266 281 282 303 320 115 125 113 121 132 16.5 18.1 15.6 16.1 17.7 0.60 0.42 0.75 0.62 0.43 17 13 20 17 13 1.24 1.28 1.27 1.30 1.35 5.0 5.2 5.2 5.3 5.5 275 290 291 313 330 118 129 117 124 136 17.0 18.7 16.0 16.6 18.2 0.63 0.44 0.78 0.65 0.45 16 12 19 16 12 1.25 1.29 1.29 1.31 1.36 5.0 5.2 5.3 5.4 5.5 277 293 294 316 334 120 131 118 126 137 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 17.5 0.36 12 1.37 5.6 338 142 18.9 0.37 12 1.40 5.8 348 146 19.5 0.39 11 1.42 5.8 351 148 71 - EXPANDED PERFORMANCE DATA LOW STAGE MODEL: DSXC160241A* / CA*F3636*6**+TXV+MBVC1200**-1* 13.9 0.85 23 1.31 5.4 320 120 15.0 0.88 23 1.34 5.6 330 124 15.5 0.92 22 1.35 5.6 334 125 59 13.7 0.75 20 1.30 5.4 317 119 14.8 0.77 20 1.33 5.5 327 123 15.2 0.81 19 1.34 5.6 330 124 14.3 0.76 21 1.34 5.6 345 128 15.5 0.79 21 1.37 5.7 355 132 16.0 0.83 20 1.38 5.8 359 133 63 14.2 0.62 17 1.32 5.5 341 126 15.3 0.65 17 1.36 5.7 352 130 15.8 0.68 16 1.37 5.7 355 132 15.5 0.57 17 1.38 5.7 364 139 16.8 0.60 17 1.42 5.9 375 144 17.3 0.62 16 1.43 5.9 379 145 67 15.5 0.43 13 1.37 5.7 360 138 16.8 0.45 13 1.41 5.8 372 142 17.3 0.47 12 1.42 5.9 375 144 105 12.9 0.86 21 1.35 5.7 354 124 13.9 0.89 21 1.39 5.9 365 128 14.4 0.93 20 1.40 5.9 369 129 59 12.7 0.75 19 1.34 5.7 350 123 13.7 0.78 18 1.38 5.8 361 127 14.1 0.82 17 1.39 5.9 365 128 13.2 0.77 20 1.38 5.9 381 132 14.4 0.79 19 1.42 6.0 393 136 14.8 0.83 19 1.43 6.1 397 138 63 13.1 0.63 16 1.37 5.8 377 131 14.2 0.65 16 1.41 6.0 389 135 14.6 0.68 15 1.42 6.0 393 136 14.3 0.58 16 1.43 6.1 402 144 15.5 0.60 16 1.47 6.2 415 149 16.0 0.63 15 1.48 6.3 419 150 67 14.4 0.44 12 1.42 6.0 398 143 15.6 0.45 12 1.46 6.2 411 147 16.0 0.47 11 1.47 6.2 415 149 15.4 0.37 11 1.48 6.3 420 154 16.7 0.39 11 1.52 6.5 433 158 17.2 0.41 11 1.53 6.5 437 160 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 16.6 0.37 12 1.43 5.9 380 149 18.0 0.38 12 1.47 6.1 391 153 18.5 0.40 11 1.48 6.2 395 155 71 - 115 COOLING OPERATION COOLING PERFORMANCE DATA DSXC160241A*-LOW STAGE 608 540 473 608 540 473 Airflow 17.4 0.75 25 1.11 4.4 227 118 18.8 0.77 25 1.14 4.5 234 121 19.4 0.81 24 1.15 4.6 237 123 67 MBh 16.3 16.6 S/T 0.86 0.83 Delta T 27 27 KW 1.05 1.08 AMPS 4.2 4.3 HI PR 200 215 LO PR 101 108 MBh 17.6 18.0 S/T 0.89 0.86 Delta T 27 26 KW 1.08 1.10 AMPS 4.3 4.4 HI PR 206 222 LO PR 104 111 MBh 18.2 18.5 S/T 0.93 0.90 Delta T 25.62 25 KW 1.09 1.11 AMPS 4.4 4.4 HI PR 208 224 LO PR 106 112 63 17.5 0.62 21 1.10 4.4 225 117 18.9 0.65 21 1.13 4.5 232 120 19.5 0.68 20 1.14 4.5 234 121 59 16.0 0.82 25 1.05 4.2 198 100 17.3 0.85 25 1.07 4.3 204 103 17.9 0.89 24 1.08 4.3 206 104 16.3 0.77 24 1.07 4.3 213 107 17.7 0.80 24 1.09 4.4 220 110 18.2 0.83 23 1.10 4.4 222 111 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 71 18.5 0.61 22 1.15 4.6 237 125 20.1 0.63 21 1.18 4.7 244 129 20.7 0.66 21 1.19 4.7 247 131 18.7 0.47 17 1.14 4.5 235 124 20.2 0.48 17 1.17 4.7 242 128 20.8 0.51 16 1.18 4.7 244 129 59 15.9 0.89 27 1.14 4.5 224 107 17.2 0.92 27 1.17 4.6 231 110 17.7 0.97 26 1.18 4.7 234 112 15.6 0.85 26 1.13 4.5 222 106 16.9 0.88 25 1.16 4.6 229 109 17.4 0.92 24 1.17 4.6 231 110 63 16.2 0.86 27 1.16 4.6 241 114 17.6 0.89 27 1.19 4.7 249 117 18.1 0.93 26 1.20 4.8 251 119 16.0 0.79 25 1.15 4.6 239 113 17.3 0.82 24 1.18 4.7 246 116 17.8 0.86 23 1.19 4.7 249 117 75 67 17.0 0.77 26 1.20 4.8 255 124 18.4 0.80 25 1.23 4.9 263 128 18.9 0.84 24 1.24 4.9 265 130 17.1 0.65 21 1.19 4.7 252 123 18.5 0.67 21 1.22 4.9 260 127 19.0 0.70 20 1.23 4.9 263 128 71 18.1 0.63 22 1.24 4.9 266 132 19.6 0.65 22 1.27 5.1 274 137 20.2 0.68 21 1.28 5.1 277 138 18.2 0.48 17 1.23 4.9 263 131 19.8 0.50 17 1.26 5.0 271 135 20.3 0.53 16 1.27 5.1 274 137 15.5 0.91 28 1.21 4.9 255 111 16.8 0.94 27 1.24 5.0 263 115 17.3 0.99 26 1.25 5.1 266 116 15.3 0.87 26 1.20 4.8 253 110 16.5 0.90 25 1.23 5.0 260 114 17.0 0.94 24 1.24 5.0 263 115 15.8 0.88 27 1.24 5.0 275 118 17.1 0.91 27 1.27 5.1 283 122 17.7 0.96 26 1.28 5.2 286 123 15.6 0.81 25 1.23 5.0 272 117 16.9 0.85 24 1.26 5.1 280 121 17.4 0.89 23 1.27 5.1 283 122 16.6 0.79 26 1.28 5.2 290 129 17.9 0.82 25 1.31 5.3 299 133 18.5 0.86 24 1.32 5.3 302 135 16.7 0.66 21 1.27 5.1 287 128 18.0 0.69 21 1.30 5.3 296 132 18.6 0.72 20 1.31 5.3 299 133 17.7 0.64 22 1.32 5.3 302 138 19.1 0.67 22 1.36 5.5 312 142 19.7 0.70 21 1.37 5.5 315 143 17.8 0.50 17 1.31 5.3 299 136 19.3 0.51 17 1.34 5.4 309 141 19.9 0.54 16 1.36 5.5 312 142 15.1 0.94 28 1.27 5.2 291 117 16.4 0.98 27 1.31 5.4 300 121 16.9 1.00 26 1.32 5.4 303 122 14.9 0.90 26 1.26 5.2 288 116 16.1 0.93 26 1.30 5.3 297 119 16.6 1.00 25 1.31 5.4 300 121 15.4 0.91 27 1.30 5.3 313 124 16.7 0.94 27 1.34 5.5 322 128 17.2 0.99 26 1.35 5.5 326 130 15.2 0.84 25 1.29 5.3 310 123 16.5 0.87 24 1.33 5.4 319 127 17.0 0.91 23 1.34 5.5 322 128 16.2 0.82 26 1.35 5.5 330 136 17.5 0.85 25 1.38 5.6 340 140 18.0 0.89 24 1.39 5.7 344 141 16.2 0.68 22 1.33 5.5 327 134 17.6 0.71 21 1.37 5.6 337 139 18.1 0.74 20 1.38 5.6 340 140 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 17.2 0.66 22 1.39 5.7 344 145 18.7 0.69 22 1.43 5.9 355 149 19.2 0.72 21 1.44 5.9 359 151 17.4 0.51 17 1.38 5.6 341 143 18.8 0.53 17 1.42 5.8 351 148 19.4 0.56 16 1.43 5.9 355 149 71 EXPANDED PERFORMANCE DATA LOW STAGE MODEL: DSXC160241A* / CA*F3636*6**+TXV+MBVC1200**-1* 59 14.4 0.98 27 1.33 5.5 327 123 15.6 1.00 27 1.36 5.7 337 126 16.1 1.00 24 1.38 5.7 340 128 14.1 0.93 26 1.32 5.5 324 121 15.3 0.97 25 1.35 5.6 334 125 15.8 1.00 24 1.36 5.7 337 126 63 14.7 0.94 27 1.36 5.7 352 130 15.9 0.98 26 1.39 5.8 363 134 16.4 1.00 25 1.41 5.9 366 136 14.4 0.87 25 1.35 5.6 348 129 15.6 0.91 24 1.38 5.8 359 133 16.1 0.95 23 1.39 5.8 363 134 67 15.4 0.85 25 1.40 5.8 371 142 16.6 0.88 25 1.44 6.0 383 147 17.1 0.92 24 1.45 6.1 387 148 15.4 0.71 21 1.39 5.8 368 141 16.7 0.74 21 1.43 5.9 379 145 17.2 0.77 20 1.44 6.0 383 147 105 71 59 13.3 0.98 26 1.38 5.8 361 127 14.4 1.00 25 1.41 6.0 372 131 14.9 1.00 23 1.42 6.1 376 132 13.1 0.94 24 1.36 5.8 358 125 14.2 0.97 24 1.40 5.9 369 129 14.6 1.00 22 1.41 6.0 372 131 63 13.6 0.95 25 1.41 6.0 389 135 14.7 0.98 25 1.44 6.1 401 139 15.2 1.00 23 1.46 6.2 405 140 13.4 0.88 23 1.40 5.9 385 133 14.5 0.91 23 1.43 6.1 397 138 14.9 0.96 22 1.44 6.1 401 139 67 14.2 0.86 24 1.46 6.2 410 147 15.4 0.89 23 1.49 6.3 423 152 15.9 0.93 22 1.51 6.4 427 153 14.3 0.72 20 1.44 6.1 406 146 15.5 0.74 20 1.48 6.3 419 150 16.0 0.78 19 1.49 6.3 423 152 71 15.2 0.70 21 1.51 6.4 428 157 16.4 0.72 20 1.55 6.6 441 162 16.9 0.76 19 1.56 6.6 446 163 15.3 0.54 16 1.49 6.3 424 155 16.6 0.56 16 1.53 6.5 437 160 17.1 0.58 15 1.55 6.6 441 162 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 16.4 0.69 22 1.45 6.1 387 152 17.7 0.72 22 1.49 6.2 399 156 18.3 0.75 21 1.50 6.3 403 158 16.5 0.53 17 1.44 6.0 384 150 17.9 0.55 17 1.48 6.2 395 155 18.4 0.58 16 1.49 6.2 399 156 115 COOLING OPERATION COOLING PERFORMANCE DATA DSXC160241A*-LOW STAGE 41 42 878 780 683 878 780 683 Airflow 59 21.1 0.65 18 1.37 5.3 203 97 22.8 0.67 18 1.41 5.4 209 100 23.5 0.70 17 1.42 5.5 211 101 21.4 0.73 21 1.39 5.3 205 98 23.2 0.76 21 1.42 5.5 211 101 23.9 0.80 20 1.43 5.5 213 102 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 22.1 0.66 20 1.42 5.5 220 104 23.9 0.68 19 1.45 5.6 227 108 24.6 0.71 18 1.47 5.7 229 109 63 21.8 0.54 16 1.41 5.4 218 103 23.7 0.56 16 1.44 5.6 225 107 24.4 0.59 15 1.45 5.6 227 108 23.9 0.50 16 1.46 5.6 233 114 25.9 0.52 16 1.50 5.8 240 118 26.7 0.54 15 1.52 5.9 242 119 67 23.9 0.37 12 1.45 5.6 230 113 25.9 0.39 12 1.49 5.8 237 116 26.7 0.41 11 1.50 5.8 240 118 25.6 0.32 11 1.51 5.9 243 121 27.8 0.33 11 1.55 6.0 250 125 28.6 0.35 10 1.57 6.1 253 126 71 20.9 0.76 21 1.50 5.8 230 104 22.7 0.79 21 1.54 5.9 237 107 23.4 0.83 20 1.55 6.0 239 108 59 20.6 0.67 19 1.49 5.7 227 103 22.3 0.69 18 1.53 5.9 234 106 23.0 0.73 18 1.54 5.9 237 107 21.6 0.68 20 1.53 5.9 247 110 23.4 0.71 19 1.57 6.1 255 114 24.1 0.74 19 1.59 6.1 257 115 63 21.3 0.56 16 1.52 5.9 245 109 23.1 0.58 16 1.56 6.0 252 113 23.8 0.61 15 1.57 6.1 255 114 75 23.3 0.52 16 1.58 6.1 261 121 25.3 0.53 16 1.63 6.3 269 124 26.0 0.56 15 1.64 6.3 272 125 67 23.4 0.39 12 1.57 6.0 258 119 25.3 0.40 12 1.61 6.2 266 123 26.1 0.42 12 1.63 6.3 269 124 25.0 0.33 11 1.64 6.3 272 128 27.1 0.34 11 1.68 6.5 281 132 27.9 0.36 11 1.70 6.6 283 134 71 20.4 0.78 22 1.60 6.3 261 108 22.1 0.81 21 1.64 6.4 269 111 22.8 0.85 20 1.66 6.5 272 112 59 20.1 0.69 19 1.58 6.2 259 107 21.8 0.71 18 1.63 6.4 267 110 22.4 0.75 18 1.64 6.4 269 111 21.0 0.70 20 1.64 6.4 281 115 22.8 0.72 19 1.68 6.6 290 118 23.5 0.76 19 1.69 6.7 293 119 22.8 0.53 16 1.69 6.6 297 125 24.7 0.55 16 1.74 6.8 306 129 25.4 0.57 15 1.75 6.9 309 130 24.4 0.34 11 1.75 6.9 310 133 26.5 0.35 11 1.80 7.1 319 138 27.3 0.37 11 1.81 7.1 322 139 19.9 0.81 22 1.69 6.7 297 113 21.6 0.84 21 1.73 6.9 307 117 22.2 0.88 20 1.75 7.0 310 118 20.5 0.72 20 1.73 6.9 320 121 22.2 0.75 20 1.77 7.1 330 124 22.9 0.78 19 1.79 7.1 333 125 22.2 0.55 16 1.79 7.1 338 132 24.1 0.57 16 1.83 7.3 348 136 24.8 0.59 15 1.85 7.4 352 137 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 20.8 22.8 19.6 20.3 22.3 0.57 0.40 0.71 0.59 0.41 16 12 19 16 12 1.62 1.68 1.67 1.71 1.77 6.4 6.6 6.6 6.8 7.0 278 294 294 317 335 114 124 112 119 130 22.6 24.7 21.2 22.0 24.1 0.60 0.41 0.74 0.61 0.43 16 12 18 16 12 1.66 1.72 1.72 1.76 1.82 6.5 6.8 6.8 7.0 7.2 287 303 304 327 345 117 128 116 123 134 23.2 25.5 21.9 22.7 24.8 0.62 0.43 0.77 0.64 0.45 15 12 18 15 12 1.68 1.74 1.73 1.77 1.83 6.6 6.8 6.9 7.1 290 306 307 330 348 118 129 117 124 136 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB* 65 23.8 0.35 11 1.85 7.4 353 140 25.8 0.36 11 1.90 7.6 363 144 26.6 0.38 11 1.92 7.6 367 146 71 - EXPANDED PERFORMANCE DATA HIGH STAGE MODEL: DSXC160241A* / CA*F3636*6**+TXV+MBVC1200**-1* 18.9 0.84 21 1.76 7.1 335 119 20.5 0.87 21 1.81 7.3 345 122 21.1 0.91 20 1.83 7.4 348 124 59 18.6 0.74 18 1.75 7.1 331 118 20.2 0.76 18 1.79 7.3 342 121 20.8 0.80 17 1.81 7.3 345 122 19.5 0.75 20 1.80 7.3 360 126 21.1 0.78 19 1.85 7.5 371 130 21.8 0.81 19 1.87 7.6 375 132 63 19.3 0.61 16 1.79 7.2 356 125 20.9 0.64 16 1.84 7.4 368 129 21.5 0.67 15 1.85 7.5 371 130 21.1 0.57 16 1.87 7.5 380 138 22.9 0.59 16 1.92 7.8 392 142 23.6 0.62 15 1.93 7.8 396 144 67 21.1 0.43 12 1.85 7.5 376 136 22.9 0.44 12 1.90 7.7 388 141 23.6 0.46 11 1.92 7.8 392 142 105 17.5 0.84 20 1.83 7.6 370 123 19.0 0.88 20 1.88 7.8 381 127 19.6 0.92 19 1.89 7.8 385 128 59 17.3 0.74 17 1.81 7.5 366 122 18.7 0.77 17 1.86 7.7 377 125 19.3 0.81 16 1.88 7.8 381 127 18.1 0.75 18 1.87 7.7 398 131 19.6 0.78 18 1.92 8.0 410 135 20.2 0.82 17 1.94 8.0 414 136 63 17.9 0.62 15 1.85 7.7 394 129 19.4 0.64 15 1.90 7.9 406 133 20.0 0.67 14 1.92 8.0 410 135 19.6 0.57 15 1.93 8.0 420 143 21.2 0.59 15 1.99 8.2 433 147 21.8 0.62 14 2.00 8.3 437 148 67 19.6 0.43 11 1.92 7.9 416 141 21.2 0.45 11 1.97 8.2 429 146 21.9 0.47 11 1.99 8.2 433 147 21.0 0.37 10 2.00 8.3 438 152 22.7 0.38 10 2.06 8.5 452 157 23.4 0.40 10 2.08 8.6 456 158 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 22.7 0.36 11 1.93 7.8 397 147 24.5 0.38 11 1.98 8.1 409 151 25.3 0.40 10 2.00 8.1 413 153 71 - 115 COOLING OPERATION COOLING PERFORMANCE DATA DSXC160241A*-HIGH STAGE 878 780 683 878 780 683 Airflow 63 22.3 0.76 23 1.43 5.5 222 106 24.1 0.78 22 1.47 5.7 229 109 24.9 0.82 21 1.48 5.7 232 110 22.6 0.82 25 1.44 5.6 225 107 24.5 0.85 24 1.48 5.7 232 110 25.2 0.89 23 1.49 5.8 234 111 59 21.8 0.81 24 1.40 5.4 207 99 23.6 0.84 23 1.43 5.5 213 102 24.3 0.88 22 1.45 5.6 215 103 MBh 22.2 S/T 0.85 Delta T 25 KW 1.41 AMPS 5.4 209 HI PR LO PR 100 MBh 24.0 S/T 0.88 Delta T 25 KW 1.45 AMPS 5.6 HI PR 215 LO PR 103 MBh 24.8 S/T 0.92 Delta T 23.85 KW 1.46 AMPS 5.6 HI PR 217 LO PR 104 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 23.7 0.74 23 1.49 5.7 237 116 25.7 0.76 23 1.53 5.9 245 120 26.4 0.80 22 1.54 6.0 247 121 67 23.8 0.62 20 1.48 5.7 235 115 25.8 0.64 19 1.52 5.9 242 119 26.6 0.67 19 1.53 5.9 245 120 25.3 0.60 20 1.54 6.0 247 124 27.4 0.62 20 1.58 6.1 255 128 28.2 0.65 19 1.59 6.2 258 129 71 25.5 0.46 16 1.53 5.9 245 123 27.6 0.48 16 1.57 6.1 253 126 28.4 0.50 15 1.58 6.1 255 128 21.7 0.88 26 1.52 5.9 234 106 23.5 0.91 25 1.57 6.0 242 109 24.2 0.95 24 1.58 6.1 244 110 59 21.3 0.84 24 1.51 5.8 232 105 23.1 0.87 24 1.55 6.0 239 108 23.8 0.91 23 1.57 6.0 242 109 22.1 0.85 25 1.56 6.0 252 113 23.9 0.88 25 1.60 6.2 260 116 24.7 0.92 24 1.61 6.2 263 117 63 21.8 0.78 23 1.55 6.0 250 112 23.6 0.81 23 1.59 6.1 257 115 24.3 0.85 22 1.60 6.2 260 116 75 23.1 0.76 24 1.61 6.2 266 123 25.1 0.79 23 1.66 6.4 274 127 25.8 0.83 22 1.67 6.4 277 128 67 23.3 0.64 20 1.60 6.2 264 122 25.2 0.66 20 1.64 6.3 272 125 26.0 0.69 19 1.66 6.4 274 127 24.7 0.62 21 1.67 6.4 278 131 26.8 0.64 20 1.71 6.6 286 135 27.6 0.67 19 1.73 6.7 289 136 71 24.9 0.48 16 1.65 6.4 275 130 26.9 0.49 16 1.70 6.6 283 134 27.7 0.52 15 1.71 6.6 286 135 21.2 0.90 26 1.63 6.4 266 110 22.9 0.93 25 1.67 6.6 275 113 23.6 0.98 24 1.68 6.6 277 115 59 20.8 0.86 24 1.61 6.3 264 109 22.5 0.89 24 1.66 6.5 272 112 23.2 0.93 23 1.67 6.6 275 113 21.6 0.87 25 1.66 6.5 287 117 23.4 0.90 25 1.71 6.7 296 121 24.1 0.94 24 1.72 6.8 299 122 22.6 0.78 24 1.72 6.8 303 128 24.5 0.81 23 1.77 6.9 312 132 25.2 0.85 22 1.78 7.0 315 133 24.1 0.63 21 1.78 7.0 316 136 26.1 0.66 20 1.83 7.2 326 140 26.9 0.69 19 1.85 7.3 329 142 20.6 0.93 26 1.72 6.8 303 116 22.4 0.96 25 1.76 7.0 313 119 23.0 1.00 24 1.78 7.1 316 120 21.0 0.89 25 1.76 7.0 327 123 22.8 0.93 25 1.80 7.2 337 127 23.5 0.97 24 1.82 7.3 340 128 22.0 0.81 24 1.82 7.2 345 134 23.9 0.84 24 1.87 7.4 356 138 24.6 0.88 23 1.88 7.5 359 140 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 21.3 22.7 24.3 20.3 20.7 22.2 0.80 0.65 0.49 0.88 0.83 0.67 20 23 20 16 24 23 1.65 1.71 1.77 1.70 1.74 1.80 6.5 6.7 6.9 6.8 6.9 7.2 284 300 313 300 323 341 116 127 135 114 122 133 23.0 24.6 26.3 22.0 22.5 24.0 0.83 0.68 0.51 0.92 0.86 0.70 20 23 20 16 24 23 1.69 1.75 1.81 1.75 1.79 1.85 6.7 6.9 7.1 7.0 7.1 7.4 293 309 322 310 333 352 119 130 139 118 125 137 23.7 25.3 27.1 22.6 23.1 24.7 0.87 0.71 0.53 0.96 0.90 0.73 22 19 15 23 22 19 1.71 1.77 1.83 1.76 1.80 1.87 6.7 6.9 7.2 7.0 7.2 7.4 296 312 326 313 337 356 121 132 140 119 127 138 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 23.5 0.65 21 1.88 7.5 360 143 25.5 0.68 20 1.93 7.7 371 147 26.2 0.71 20 1.95 7.8 375 149 71 23.7 0.50 16 1.86 7.4 356 142 25.7 0.52 16 1.92 7.6 367 146 26.4 0.55 15 1.93 7.7 371 147 EXPANDED PERFORMANCE DATA HIGH STAGE MODEL: DSXC160241A* / CA*F3636*6**+TXV+MBVC1200**-1* 19.6 0.96 25 1.79 7.3 341 121 21.2 1.00 25 1.84 7.5 352 125 21.9 1.00 23 1.86 7.5 355 126 59 19.3 0.92 24 1.78 7.2 338 120 20.9 0.95 23 1.83 7.4 348 124 21.5 1.00 23 1.84 7.5 352 125 20.0 0.93 25 1.83 7.4 367 129 21.7 0.96 25 1.88 7.7 379 133 22.3 1.00 23 1.90 7.7 383 134 63 19.7 0.86 23 1.82 7.4 364 128 21.3 0.89 22 1.87 7.6 375 132 22.0 0.94 22 1.88 7.7 379 133 20.9 0.84 24 1.90 7.7 388 141 22.7 0.87 23 1.95 7.9 400 145 23.4 0.91 22 1.97 8.0 404 146 67 21.0 0.70 20 1.88 7.6 384 139 22.8 0.73 20 1.93 7.8 396 144 23.5 0.76 19 1.95 7.9 400 145 105 18.2 0.97 24 1.86 7.7 377 125 19.7 1.00 23 1.91 7.9 389 129 20.3 1.00 21 1.93 8.0 393 130 59 17.9 0.93 22 1.84 7.6 373 124 19.3 0.96 22 1.89 7.8 385 128 19.9 1.00 21 1.91 7.9 389 129 18.5 0.94 23 1.90 7.9 406 133 20.1 0.97 23 1.95 8.1 418 137 20.7 1.00 22 1.97 8.2 423 139 63 18.2 0.87 21 1.89 7.8 402 132 19.8 0.90 21 1.94 8.0 414 136 20.4 0.94 20 1.95 8.1 418 137 19.4 0.84 22 1.97 8.1 429 145 21.0 0.88 22 2.02 8.4 442 150 21.6 0.92 21 2.04 8.5 446 151 67 19.5 0.71 19 1.95 8.1 424 144 21.1 0.73 18 2.00 8.3 438 149 21.8 0.77 18 2.02 8.4 442 150 20.7 0.69 19 2.04 8.5 447 155 22.4 0.71 19 2.09 8.7 461 160 23.1 0.75 18 2.11 8.8 466 161 71 20.8 0.53 15 2.02 8.4 443 153 22.6 0.55 15 2.08 8.6 456 158 23.3 0.57 14 2.09 8.7 461 160 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 22.3 0.68 20 1.97 8.0 405 150 24.2 0.70 20 2.02 8.2 417 154 24.9 0.74 19 2.04 8.3 421 156 71 22.5 0.52 16 1.95 7.9 401 148 24.4 0.54 16 2.00 8.1 413 153 25.1 0.57 15 2.02 8.2 417 154 115 COOLING OPERATION COOLING PERFORMANCE DATA DSXC160241A*-HIGH STAGE 43 44 * 75 70 IDB* 59 22.7 0.67 21 1.42 5.6 198 104 24.5 0.70 20 1.45 5.8 204 107 25.3 0.73 19 1.47 5.8 206 108 23.0 0.77 24 1.43 5.7 200 105 25.0 0.79 23 1.47 5.8 206 108 25.7 0.83 22 1.48 5.9 208 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 23.7 0.69 22 1.46 5.8 215 111 25.7 0.71 22 1.50 5.9 222 115 26.5 0.75 21 1.51 6.0 224 116 63 23.5 0.56 18 1.45 5.7 213 110 25.4 0.58 18 1.49 5.9 220 114 26.2 0.61 17 1.50 5.9 222 115 25.7 0.52 18 1.51 6.0 227 122 27.8 0.54 18 1.55 6.1 234 125 28.7 0.56 17 1.56 6.2 237 127 67 25.7 0.39 14 1.50 5.9 225 120 27.9 0.40 13 1.54 6.1 232 124 28.7 0.42 13 1.55 6.1 234 125 27.6 0.33 12 1.56 6.2 237 129 29.9 0.35 12 1.60 6.3 244 133 30.8 0.36 12 1.61 6.4 247 135 71 - Entering Indoor Dry Bulb Temperature 878 780 683 878 780 683 Airflow 65 22.5 0.79 24 1.54 6.1 224 111 24.4 0.82 24 1.58 6.3 231 114 25.1 0.86 23 1.60 6.3 234 115 59 22.1 0.70 21 1.53 6.0 222 109 24.0 0.72 20 1.57 6.2 229 113 24.7 0.76 20 1.58 6.3 231 114 25.1 0.54 18 1.63 6.4 255 128 27.2 0.56 18 1.67 6.6 263 132 28.0 0.58 17 1.69 6.7 266 134 67 25.1 0.40 14 1.62 6.4 252 127 27.2 0.42 13 1.66 6.5 260 131 28.0 0.44 13 1.67 6.6 263 132 26.9 0.35 13 1.69 6.7 266 137 29.2 0.36 12 1.73 6.8 274 141 30.0 0.38 12 1.75 6.9 277 142 71 22.0 0.81 24 1.65 6.6 255 115 23.8 0.84 24 1.69 6.8 263 118 24.5 0.89 23 1.70 6.8 266 120 59 21.6 0.72 21 1.63 6.5 253 114 23.4 0.74 21 1.67 6.7 260 117 24.1 0.78 20 1.69 6.8 263 118 22.6 0.73 22 1.68 6.7 275 122 24.5 0.76 22 1.73 6.9 283 126 25.2 0.79 21 1.74 7.0 286 127 24.5 0.55 18 1.74 7.0 290 133 26.5 0.57 18 1.79 7.1 299 138 27.3 0.60 17 1.80 7.2 302 139 26.3 0.35 13 1.80 7.2 303 142 28.5 0.37 12 1.85 7.4 312 147 29.3 0.39 12 1.86 7.5 315 148 NOTE: Shaded area is ACCA (TVA) conditions 23.2 0.71 22 1.58 6.2 242 118 25.1 0.74 22 1.62 6.4 249 121 25.9 0.77 21 1.63 6.5 251 122 63 22.9 0.58 18 1.57 6.2 239 116 24.8 0.61 18 1.61 6.3 246 120 25.6 0.63 17 1.62 6.4 249 121 75 21.4 0.84 24 1.73 7.0 291 121 23.2 0.87 24 1.78 7.2 300 124 23.9 0.91 23 1.80 7.3 303 126 22.1 0.75 22 1.77 7.2 313 128 23.9 0.78 22 1.82 7.4 323 132 24.6 0.82 21 1.84 7.4 326 134 23.9 0.57 18 1.83 7.4 330 140 25.9 0.59 18 1.88 7.6 341 145 26.7 0.62 17 1.90 7.7 344 146 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 22.4 24.5 21.1 21.8 23.9 0.60 0.41 0.74 0.62 0.43 18 14 21 18 14 1.67 1.72 1.72 1.76 1.82 6.7 6.9 7.0 7.1 7.3 272 287 288 310 327 121 132 119 127 139 24.3 26.6 22.8 23.7 25.9 0.62 0.43 0.77 0.64 0.44 18 13 21 18 14 1.71 1.77 1.77 1.81 1.87 6.9 7.1 7.1 7.3 7.5 280 296 297 319 337 125 136 123 131 143 25.0 27.4 23.5 24.4 26.7 0.65 0.45 0.80 0.67 0.47 17 13 20 17 13 1.73 1.79 1.78 1.82 1.88 6.9 7.1 7.2 7.4 7.6 283 299 300 322 340 126 138 124 132 145 25.6 0.37 13 1.90 7.7 345 149 27.8 0.38 12 1.95 7.9 355 154 28.6 0.40 12 1.97 8.0 359 155 71 - EXPANDED PERFORMANCE DATA MODEL: DSXC160361A* / CA*F3743*6**+TXV+MBVC1600**-1* LOW STAGE 20.4 0.87 24 1.81 7.4 327 127 22.1 0.90 24 1.86 7.7 337 130 22.7 0.95 23 1.87 7.7 341 132 59 20.0 0.77 21 1.79 7.4 324 125 21.7 0.80 20 1.84 7.6 334 129 22.3 0.83 20 1.86 7.6 337 130 21.0 0.78 22 1.85 7.6 352 135 22.7 0.81 22 1.90 7.8 363 139 23.4 0.85 21 1.92 7.9 366 140 63 20.8 0.64 18 1.84 7.6 348 133 22.5 0.66 18 1.88 7.8 359 137 23.2 0.70 17 1.90 7.8 363 139 22.7 0.59 18 1.92 7.9 372 147 24.6 0.61 18 1.97 8.1 383 151 25.3 0.64 17 1.98 8.2 387 153 67 22.7 0.44 14 1.90 7.8 368 145 24.6 0.46 13 1.95 8.0 379 150 25.4 0.48 13 1.97 8.1 383 151 105 24.4 0.38 12 1.98 8.2 388 156 26.4 0.39 12 2.04 8.4 400 161 27.2 0.41 12 2.05 8.5 404 163 71 18.9 0.88 22 1.88 7.9 361 131 20.4 0.91 22 1.93 8.1 373 135 21.0 0.96 21 1.94 8.2 376 136 59 18.5 0.77 19 1.86 7.8 358 130 20.1 0.80 19 1.91 8.0 369 134 20.7 0.84 18 1.93 8.1 372 135 19.4 0.79 21 1.92 8.1 389 139 21.0 0.82 20 1.97 8.3 401 144 21.7 0.86 19 1.99 8.4 405 145 63 19.2 0.65 17 1.90 8.0 385 138 20.8 0.67 16 1.95 8.2 397 142 21.5 0.70 16 1.97 8.3 401 143 21.0 0.60 17 1.99 8.3 411 152 22.8 0.62 17 2.04 8.5 423 157 23.5 0.65 16 2.06 8.6 428 158 67 21.1 0.45 13 1.97 8.2 406 150 22.8 0.46 12 2.02 8.5 419 155 23.5 0.49 12 2.04 8.5 423 157 115 22.6 0.38 12 2.05 8.6 428 162 24.4 0.40 11 2.11 8.9 442 167 25.2 0.42 11 2.13 8.9 446 169 71 - COOLING OPERATION COOLING PERFORMANCE DATA DSXC160361A*-LOW STAGE * 85 80 IDB* 67 25.6 0.64 22 1.52 6.0 230 123 27.7 0.67 22 1.56 6.2 237 127 28.6 0.70 21 1.57 6.2 239 128 25.5 0.77 26 1.54 6.1 232 124 27.6 0.80 26 1.57 6.2 239 128 28.4 0.83 25 1.59 6.3 241 129 MBh 23.9 24.3 0.88 0.85 S/T 28 28 Delta T KW 1.45 1.49 AMPS 5.8 5.9 204 220 HI PR LO PR 107 114 MBh 25.8 26.3 0.91 0.88 S/T Delta T 28 27 KW 1.49 1.52 AMPS 5.9 6.0 HI PR 210 226 LO PR 110 117 MBh 26.6 27.1 0.96 0.92 S/T Delta T 26.73 26 KW 1.50 1.54 AMPS 6.0 6.1 HI PR 212 229 LO PR 111 118 59 23.4 0.84 27 1.44 5.7 202 106 25.4 0.87 26 1.48 5.9 208 109 26.2 0.91 25 1.49 5.9 210 110 63 24.0 0.79 25 1.47 5.8 217 112 26.0 0.82 25 1.51 6.0 224 116 26.7 0.86 24 1.52 6.0 226 117 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 27.2 0.62 23 1.59 6.3 242 132 29.4 0.65 22 1.63 6.4 249 136 30.3 0.68 22 1.64 6.5 252 138 71 27.4 0.48 18 1.57 6.2 239 131 29.6 0.50 17 1.61 6.4 247 135 30.5 0.52 17 1.63 6.4 249 136 Entering Indoor Dry Bulb Temperature 878 780 683 878 780 683 Airflow 65 23.3 0.91 29 1.57 6.2 229 113 25.2 0.95 28 1.61 6.4 236 116 26.0 0.99 27 1.63 6.4 238 117 59 22.9 0.87 27 1.56 6.1 227 112 24.8 0.90 26 1.60 6.3 234 115 25.6 0.95 25 1.61 6.4 236 116 24.9 0.80 27 1.66 6.5 260 131 27.0 0.82 26 1.70 6.7 268 135 27.8 0.86 25 1.72 6.8 271 136 67 25.0 0.67 22 1.65 6.5 258 130 27.1 0.69 22 1.69 6.7 266 134 27.9 0.72 21 1.70 6.7 268 135 26.5 0.65 23 1.72 6.8 271 140 28.8 0.67 23 1.76 7.0 280 144 29.6 0.70 22 1.78 7.0 283 145 71 26.7 0.50 18 1.70 6.7 269 138 29.0 0.52 18 1.75 6.9 277 142 29.8 0.54 17 1.76 7.0 280 144 22.7 0.94 29 1.67 6.7 260 117 24.6 0.97 28 1.72 6.9 268 121 25.4 1.00 27 1.73 6.9 271 122 59 22.4 0.89 27 1.66 6.6 258 116 24.2 0.93 26 1.70 6.8 266 120 25.0 1.00 26 1.72 6.9 268 121 23.2 0.90 28 1.71 6.9 280 125 25.1 0.94 28 1.76 7.0 289 129 25.9 0.98 27 1.77 7.1 292 130 24.3 0.82 27 1.77 7.1 296 136 26.3 0.85 26 1.82 7.3 305 140 27.1 0.89 25 1.83 7.3 308 142 25.9 0.66 23 1.83 7.3 309 145 28.1 0.69 23 1.88 7.5 318 150 28.9 0.72 22 1.90 7.6 321 151 NOTE: Shaded area is AHRI Rating Conditions 23.8 0.88 28 1.61 6.3 246 120 25.7 0.91 28 1.65 6.5 254 124 26.5 0.96 27 1.66 6.6 257 125 63 23.4 0.82 26 1.59 6.3 244 119 25.4 0.85 25 1.63 6.5 251 123 26.1 0.89 24 1.65 6.5 254 124 75 22.2 0.97 29 1.76 7.1 297 123 24.0 1.00 28 1.81 7.3 306 127 24.8 1.00 26 1.83 7.4 309 128 22.6 0.93 28 1.81 7.3 319 131 24.5 0.97 28 1.85 7.5 329 135 25.2 1.00 26 1.87 7.6 332 136 23.7 0.84 27 1.87 7.5 337 143 25.7 0.87 26 1.92 7.7 347 147 26.4 0.92 25 1.93 7.8 351 149 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 22.8 24.4 26.1 21.8 22.3 23.8 0.84 0.68 0.51 0.92 0.86 0.70 26 22 18 27 26 23 1.70 1.75 1.81 1.75 1.79 1.85 6.8 7.0 7.3 7.1 7.2 7.5 277 293 306 294 316 334 123 135 144 122 130 142 25.8 24.8 26.4 28.3 23.6 24.1 0.87 0.71 0.53 0.96 0.90 0.73 22 25 22 18 27 26 1.74 1.80 1.86 1.80 1.84 1.90 7.7 7.0 7.2 7.5 7.3 7.4 286 302 315 303 326 344 127 139 148 126 134 146 25.5 27.2 29.1 24.3 24.9 26.6 0.91 0.74 0.55 1.00 0.94 0.77 24 21 17 26 25 21 1.76 1.82 1.88 1.81 1.85 1.92 7.0 7.3 7.5 7.3 7.5 7.7 289 305 318 306 329 347 129 140 150 127 135 147 25.3 0.68 23 1.93 7.8 352 152 27.4 0.71 23 1.98 8.0 362 157 28.2 0.74 22 2.00 8.1 366 159 71 25.5 0.53 18 1.91 7.7 348 151 27.6 0.55 18 1.97 8.0 359 155 28.4 0.57 17 1.98 8.0 362 157 EXPANDED PERFORMANCE DATA MODEL: DSXC160361A* / CA*F3743*6**+TXV+MBVC1600**-1* LOW STAGE 21.1 1.00 28 1.84 7.6 334 129 22.8 1.00 27 1.89 7.8 344 133 23.5 1.00 25 1.91 7.9 347 134 59 20.7 0.96 27 1.83 7.5 330 128 22.5 0.99 26 1.87 7.7 341 132 23.1 1.00 24 1.89 7.8 344 133 21.5 0.97 28 1.88 7.8 359 137 23.3 1.00 27 1.93 8.0 370 142 24.0 1.00 25 1.95 8.0 374 143 63 21.2 0.90 26 1.87 7.7 355 136 22.9 0.93 25 1.92 7.9 366 140 23.6 1.00 25 1.93 8.0 370 142 22.5 0.87 26 1.95 8.0 379 150 24.4 0.91 26 2.00 8.2 391 155 25.1 0.95 25 2.02 8.3 395 156 67 22.6 0.73 22 1.93 7.9 375 148 24.5 0.76 22 1.98 8.2 387 153 25.2 0.79 21 2.00 8.2 391 155 105 24.0 0.71 23 2.02 8.3 395 160 26.0 0.74 23 2.07 8.5 408 165 26.8 0.77 22 2.09 8.6 412 166 71 24.2 0.55 18 2.00 8.2 392 158 26.2 0.57 17 2.05 8.5 404 163 27.0 0.59 17 2.07 8.5 408 165 19.5 1.00 26 1.91 8.0 369 133 21.2 1.00 25 1.96 8.2 380 138 21.8 1.00 23 1.98 8.3 384 139 59 19.2 0.97 25 1.89 7.9 365 132 20.8 1.00 25 1.94 8.2 376 136 21.4 1.00 22 1.96 8.2 380 138 19.9 0.98 26 1.95 8.2 397 142 21.6 1.00 25 2.01 8.4 409 146 22.2 1.00 23 2.02 8.5 413 148 63 19.6 0.91 24 1.94 8.1 393 141 21.3 0.94 24 1.99 8.4 405 145 21.9 1.00 23 2.01 8.4 409 146 20.9 0.88 25 2.02 8.5 419 155 22.6 0.91 24 2.07 8.7 432 160 23.3 0.96 23 2.09 8.8 436 161 67 21.0 0.74 21 2.00 8.4 415 154 22.7 0.76 20 2.06 8.6 428 158 23.4 0.80 20 2.07 8.7 432 160 115 22.2 0.71 21 2.09 8.8 437 165 24.1 0.74 21 2.15 9.0 450 170 24.8 0.78 20 2.17 9.1 455 172 71 22.4 0.55 17 2.07 8.7 433 163 24.3 0.57 16 2.13 8.9 446 169 25.0 0.60 16 2.15 9.0 450 170 COOLING OPERATION COOLING PERFORMANCE DATA DSXC160361A*-LOW STAGE 45 46 1294 1150 1006 1294 1150 1006 Airflow 59 30.7 0.67 19 2.09 8.4 216 101 33.3 0.70 19 2.14 8.6 222 104 34.3 0.73 18 2.16 8.7 225 105 31.3 0.77 22 2.11 8.4 218 102 33.9 0.79 22 2.16 8.7 225 105 34.9 0.83 21 2.18 8.8 227 106 MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR MBh S/T Delt a T KW AMPS HI PR LO PR 32.2 0.69 20 2.15 8.6 235 108 34.9 0.71 20 2.21 8.9 242 112 35.9 0.75 19 2.23 9.0 244 113 63 31.9 0.56 16 2.14 8.6 232 107 34.5 0.58 16 2.19 8.8 239 111 35.5 0.61 15 2.21 8.9 242 112 34.8 0.52 17 2.23 8.9 248 118 37.7 0.54 16 2.28 9.2 255 122 38.9 0.56 16 2.30 9.3 258 123 67 34.9 0.39 12 2.21 8.8 245 117 37.8 0.40 12 2.26 9.1 253 121 38.9 0.42 12 2.28 9.2 255 122 37.4 0.33 11 2.30 9.3 258 126 40.5 0.35 11 2.36 9.5 266 130 41.7 0.36 11 2.38 9.6 269 131 71 30.5 0.79 22 2.28 9.1 245 108 33.1 0.82 22 2.34 9.4 252 111 34.1 0.86 21 2.36 9.5 255 112 59 30.0 0.70 19 2.26 9.0 242 106 32.5 0.72 19 2.32 9.3 250 110 33.5 0.76 18 2.34 9.4 252 111 31.4 0.71 20 2.33 9.4 263 114 34.1 0.74 20 2.39 9.6 271 118 35.1 0.77 19 2.41 9.7 274 119 63 31.1 0.58 17 2.31 9.3 261 113 33.7 0.61 16 2.37 9.5 269 117 34.7 0.63 16 2.39 9.6 271 118 75 34.0 0.54 17 2.40 9.7 278 125 36.9 0.56 16 2.47 9.9 287 129 38.0 0.58 16 2.49 10.0 289 130 67 34.1 0.40 13 2.38 9.6 275 124 36.9 0.42 12 2.45 9.9 284 127 38.0 0.44 12 2.47 9.9 287 129 36.5 0.35 12 2.49 10.0 290 133 39.6 0.36 11 2.55 10.3 299 137 40.7 0.38 11 2.57 10.4 302 139 71 29.8 0.81 22 2.43 9.9 278 112 32.3 0.84 22 2.49 10.2 287 115 33.3 0.89 21 2.51 10.3 290 116 59 29.3 0.72 19 2.40 9.8 275 111 31.7 0.74 19 2.47 10.1 284 114 32.7 0.78 18 2.49 10.2 287 115 30.7 0.73 20 2.48 10.2 299 119 33.2 0.76 20 2.55 10.5 309 123 34.2 0.79 19 2.57 10.6 312 124 33.2 0.55 17 2.56 10.5 316 130 36.0 0.57 16 2.63 10.8 326 134 37.1 0.60 16 2.65 10.9 329 135 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65 35.6 0.35 12 2.65 10.9 330 138 38.6 0.37 11 2.72 11.2 340 143 39.8 0.39 11 2.75 11.3 343 144 29.1 0.84 22 2.56 10.6 317 117 31.5 0.87 22 2.62 10.9 327 121 32.4 0.91 21 2.65 11.0 330 122 29.9 0.75 21 2.61 10.9 341 125 32.4 0.78 20 2.68 11.2 352 129 33.4 0.82 19 2.71 11.3 355 130 Outdoor Ambient Temperature 95 85 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 30.4 33.3 28.6 29.6 0.60 0.41 0.74 0.62 17 13 19 17 2.46 2.54 2.53 2.59 10.1 10.4 10.5 10.8 296 313 314 338 118 129 116 124 32.9 36.1 31.0 32.1 0.62 0.43 0.77 0.64 16 12 19 16 2.52 2.61 2.60 2.66 10.4 10.7 10.8 11.1 306 323 323 348 121 132 120 127 33.9 37.1 31.9 33.1 0.65 0.45 0.80 0.67 16 12 18 16 2.54 2.63 2.62 2.68 10.5 10.8 10.9 11.2 309 326 327 352 123 134 121 129 32.4 0.57 17 2.70 11.3 360 136 35.1 0.59 17 2.78 11.6 371 141 36.2 0.62 16 2.80 11.7 375 142 67 32.5 0.43 13 2.68 11.2 356 135 35.2 0.44 12 2.75 11.5 368 139 36.2 0.47 12 2.78 11.6 371 141 71 34.8 0.37 12 2.80 11.7 376 145 37.7 0.38 11 2.87 12.0 387 150 38.8 0.40 11 2.90 12.1 391 151 EXPANDED PERFORMANCE DATA MODEL: DSXC160361A* / CA*F3743*6**+TXV+MBVC1600**-1* HIGH STAGE 27.6 0.87 22 2.67 11.3 357 123 29.9 0.90 22 2.74 11.7 368 127 30.8 0.95 21 2.76 11.8 371 128 59 27.2 0.77 19 2.64 11.2 353 122 29.4 0.80 19 2.72 11.5 364 126 30.3 0.83 18 2.74 11.7 367 127 28.4 0.78 20 2.73 11.6 384 131 30.8 0.81 20 2.80 11.9 396 135 31.7 0.85 19 2.83 12.1 399 136 63 28.2 0.64 16 2.71 11.5 380 130 30.5 0.66 16 2.78 11.8 392 134 31.4 0.70 16 2.80 11.9 395 135 30.8 0.59 17 2.82 12.0 405 143 33.3 0.61 16 2.90 12.4 418 147 34.4 0.64 16 2.92 12.5 422 149 67 30.8 0.44 13 2.80 11.9 401 141 33.4 0.46 12 2.87 12.2 413 146 34.4 0.48 12 2.90 12.3 418 147 105 25.6 0.88 21 2.76 12.0 394 127 27.7 0.91 20 2.84 12.4 406 131 28.6 0.96 19 2.86 12.5 410 133 59 25.2 0.77 18 2.74 11.9 390 126 27.3 0.80 17 2.81 12.2 402 130 28.1 0.84 17 2.84 12.4 406 131 26.3 0.79 19 2.83 12.3 424 135 28.5 0.82 19 2.90 12.7 437 140 29.4 0.86 18 2.93 12.8 441 141 63 26.1 0.65 15 2.80 12.2 420 134 28.3 0.67 15 2.88 12.5 433 138 29.1 0.70 15 2.90 12.7 437 140 28.5 0.60 16 2.93 12.7 448 148 30.9 0.62 15 3.00 13.1 461 152 31.8 0.65 15 3.03 13.2 466 154 67 28.6 0.45 12 2.90 12.6 443 146 31.0 0.46 11 2.98 13.0 457 151 31.9 0.49 11 3.00 13.1 461 152 30.6 0.38 11 3.03 13.2 467 157 33.2 0.40 11 3.11 13.6 481 162 34.2 0.42 10 3.14 13.7 486 164 71 - KW=Total system power AMPS=outdoor unit amps (comp.+fan) 33.0 0.38 11 2.92 12.5 423 152 35.8 0.39 11 3.00 12.8 436 157 36.9 0.41 11 3.03 13.0 440 158 71 - 115 COOLING PERFORMANCE DATA DSXC160361A*-HIGH STAGE 1294 1150 1006 1294 1150 1006 Airflow 59 31.8 0.84 24 2.13 8.5 220 103 34.5 0.87 24 2.18 8.8 227 106 35.5 0.91 23 2.20 8.8 229 107 32.4 0.88 26 2.14 8.6 222 104 35.1 0.91 26 2.20 8.8 229 107 36.1 0.96 25 2.22 8.9 232 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 33.0 0.85 26 2.19 8.8 239 110 35.7 0.88 25 2.25 9.1 247 114 36.8 0.92 24 2.27 9.1 249 115 63 32.5 0.79 23 2.17 8.7 237 109 35.2 0.82 23 2.23 9.0 244 113 36.3 0.86 22 2.25 9.1 247 114 34.6 0.77 24 2.26 9.1 253 121 37.4 0.80 24 2.32 9.4 261 124 38.6 0.83 23 2.34 9.4 263 126 67 34.7 0.64 20 2.24 9.0 250 119 37.6 0.67 20 2.30 9.3 258 123 38.8 0.70 19 2.32 9.4 261 124 36.9 0.62 21 2.34 9.4 264 128 39.9 0.65 21 2.40 9.7 272 132 41.1 0.68 20 2.42 9.8 275 134 71 37.1 0.48 16 2.32 9.4 261 127 40.2 0.50 16 2.38 9.6 269 131 41.4 0.52 15 2.40 9.7 272 132 31.6 0.91 26 2.32 9.3 250 110 34.3 0.95 26 2.38 9.6 257 113 35.3 0.99 25 2.40 9.7 260 114 59 31.1 0.87 25 2.30 9.2 247 109 33.7 0.90 24 2.36 9.5 255 112 34.7 0.95 23 2.38 9.6 257 113 32.2 0.88 26 2.37 9.5 269 117 34.9 0.91 26 2.43 9.8 277 120 36.0 0.96 24 2.45 9.9 280 122 63 31.7 0.82 24 2.35 9.4 266 116 34.4 0.85 23 2.41 9.7 274 119 35.4 0.89 22 2.43 9.8 277 120 75 33.8 0.80 25 2.45 9.8 284 127 36.6 0.82 24 2.51 10.1 292 131 37.7 0.86 23 2.53 10.2 295 133 67 33.9 0.67 21 2.43 9.8 281 126 36.8 0.69 20 2.49 10.0 290 130 37.9 0.72 19 2.51 10.1 292 131 36.0 0.65 21 2.53 10.2 296 136 39.0 0.67 21 2.60 10.5 305 140 40.2 0.70 20 2.62 10.6 308 141 71 36.3 0.50 16 2.51 10.1 293 134 39.3 0.52 16 2.57 10.4 302 139 40.5 0.54 16 2.60 10.5 305 140 30.9 0.94 26 2.47 10.1 284 114 33.4 0.97 26 2.53 10.4 293 118 34.4 1.00 24 2.55 10.5 296 119 59 30.3 0.89 25 2.45 10.0 281 113 32.9 0.93 24 2.51 10.3 290 116 33.8 1.00 24 2.53 10.4 293 118 31.5 0.90 26 2.52 10.4 305 121 34.1 0.94 26 2.59 10.7 315 125 35.1 0.98 25 2.61 10.8 318 126 32.9 0.82 25 2.61 10.7 323 132 35.7 0.85 24 2.68 11.0 333 137 36.8 0.89 23 2.70 11.1 336 138 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction service valves. 85 80 IDB* 65 35.1 0.66 21 2.70 11.1 336 141 38.1 0.69 21 2.77 11.5 347 145 39.2 0.72 20 2.79 11.6 350 147 30.1 0.97 27 2.60 10.8 323 120 32.6 1.00 26 2.67 11.1 333 123 33.6 1.00 24 2.69 11.2 337 125 30.7 0.93 26 2.66 11.1 348 127 33.3 0.97 26 2.73 11.4 359 131 34.2 1.00 24 2.75 11.5 362 133 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 31.0 33.1 35.4 29.6 30.2 0.84 0.68 0.51 0.92 0.86 24 21 16 25 24 2.50 2.59 2.67 2.58 2.64 10.3 10.6 11.0 10.7 11.0 302 319 333 320 344 120 131 140 119 126 33.6 35.9 38.4 32.1 32.8 0.87 0.71 0.53 0.96 0.90 23 20 16 25 23 2.57 2.65 2.75 2.65 2.71 10.6 10.9 11.3 11.0 11.3 312 329 343 330 355 124 135 144 122 130 34.6 37.0 39.5 33.0 33.7 0.91 0.74 0.55 1.00 0.94 22 19 16 23 23 2.59 2.68 2.77 2.67 2.73 10.7 11.0 11.5 11.1 11.4 315 333 347 333 359 125 137 145 123 131 32.1 0.84 25 2.75 11.5 367 139 34.8 0.87 24 2.82 11.8 379 143 35.9 0.92 23 2.85 11.9 383 145 67 32.3 0.70 21 2.73 11.4 364 138 35.0 0.73 20 2.80 11.7 375 142 36.1 0.77 20 2.82 11.8 379 143 34.3 0.68 21 2.85 11.9 383 148 37.2 0.71 21 2.92 12.3 395 153 38.3 0.74 20 2.95 12.4 399 154 71 34.5 0.53 17 2.82 11.8 379 147 37.4 0.55 16 2.90 12.2 391 151 38.5 0.57 16 2.92 12.3 395 153 EXPANDED PERFORMANCE DATA MODEL: DSXC160361A* / CA*F3743*6**+TXV+MBVC1600**-1* HIGH STAGE 28.6 1.00 26 2.71 11.5 364 126 31.0 1.00 25 2.79 11.9 375 129 31.9 1.00 23 2.81 12.0 379 131 59 28.1 0.96 25 2.69 11.4 360 124 30.5 0.99 24 2.76 11.8 371 128 31.4 1.00 22 2.79 11.9 375 129 29.2 0.97 26 2.78 11.8 391 134 31.6 1.00 25 2.85 12.2 404 138 32.5 1.00 23 2.88 12.3 408 139 63 28.7 0.90 24 2.75 11.7 388 132 31.1 0.93 23 2.83 12.1 400 136 32.1 1.00 23 2.85 12.2 404 138 30.5 0.87 24 2.87 12.2 413 146 33.1 0.91 24 2.95 12.6 426 150 34.1 0.95 23 2.98 12.7 430 152 67 30.7 0.73 20 2.85 12.1 409 144 33.3 0.76 20 2.92 12.5 422 149 34.2 0.79 19 2.95 12.6 426 150 105 26.5 1.00 24 2.81 12.2 402 130 28.7 1.00 23 2.89 12.6 414 134 29.6 1.00 21 2.91 12.7 418 135 59 26.0 0.97 23 2.79 12.1 398 129 28.2 1.00 23 2.86 12.5 410 133 29.1 1.00 21 2.89 12.6 414 134 27.0 0.98 24 2.88 12.5 432 138 29.3 1.00 23 2.96 12.9 446 142 30.1 1.00 21 2.98 13.0 450 144 63 26.6 0.91 22 2.85 12.4 428 137 28.8 0.94 22 2.93 12.8 441 141 29.7 1.00 21 2.96 12.9 446 142 28.3 0.88 23 2.98 13.0 457 151 30.6 0.91 22 3.06 13.4 471 155 31.6 0.96 21 3.08 13.5 475 157 67 28.4 0.74 19 2.95 12.9 452 149 30.8 0.76 19 3.03 13.2 466 154 31.7 0.80 18 3.06 13.4 471 155 30.2 0.71 20 3.08 13.5 476 161 32.7 0.74 19 3.16 13.9 491 166 33.7 0.78 19 3.19 14.0 496 167 71 30.4 0.55 15 3.05 13.4 472 159 32.9 0.57 15 3.14 13.7 486 164 33.9 0.60 14 3.16 13.9 491 166 KW=Total system power AMPS=outdoor unit amps (comp.+fan) 32.6 0.71 21 2.97 12.7 431 155 35.3 0.74 21 3.05 13.1 444 160 36.4 0.77 20 3.08 13.2 449 162 71 32.8 0.55 16 2.95 12.6 427 154 35.5 0.57 16 3.03 13.0 440 158 36.6 0.59 15 3.05 13.1 444 160 115 COOLING OPERATION COOLING PERFORMANCE DATA DSXC160361A*-HIGH STAGE 47 PERFORMANCE DATA ASXC160**1A* LOW STAGE *SXC160241A* / CA*F3636*6**+TXV / M BV C1200**-1** Conditions : 80°F IDB, 67°F IWB @ 600 CFM , LOW STAGE *SXC160361A* / CA*F3743*6**+TXV / MBVC1600**-1** Conditions: 80°F IDB, 67°F IWB @ 800 CFM, LOW STAGE Outdoor Te m p. ° F. Total Btuh Se ns ible Btuh Late nt Btuh Total Watts Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 19,285 13,583 5,702 1,243 75° 26,692 17,980 8,712 1,689 80° 19,056 13,592 5,463 1,285 80° 26,374 17,991 8,383 1,743 85° 18,826 13,597 5,229 1,327 85° 26,057 17,998 8,059 1,797 90° 18,597 13,648 4,949 1,363 90° 25,739 18,065 7,674 1,845 95° 18,367 13,693 4,674 1,400 95° 25,421 18,125 7,296 1,893 100° 17,908 13,604 4,304 1,431 100° 24,785 18,006 6,779 1,934 105° 17,449 13,501 3,947 1,462 105° 24,150 17,871 6,279 1,974 110° 16,806 13,058 3,747 1,489 110° 23,260 17,285 5,976 2,010 115° 16,163 12,611 3,552 1,516 115° 22,370 16,693 5,678 2,045 TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 17,020 13,556 3,464 1,353 ASXC160481A* / CA*F4860*6**+TXV / MBVC2000**-1 Conditions: 80°F IDB, 67°F IW B @ 1100 CFM, Low Stage TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 23,556 17,943 5,613 1,832 *SXC160601A* / CA*F4961*6**+TXV / MBVC2000**-1** Conditions: 80°F IDB, 67°F IWB @ 1400 CFM, LOW STAGE Outdoor Te m p. ° F. Total Btuh Se ns ible Btuh Late nt Btuh Total Watts Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 36,800 25,760 11,040 2,340 75° 44,775 31,511 13,264 2,966 80° 36,350 25,809 10,542 2,415 80° 44,242 31,532 12,711 3,066 85° 35,900 25,848 10,052 2,490 85° 43,709 31,543 12,166 3,166 90° 35,450 25,879 9,572 2,555 90° 43,176 31,660 11,516 3,255 95° 35,000 25,900 9,100 2,620 95° 42,643 31,765 10,878 3,343 100° 34,150 25,783 8,367 2,680 100° 41,577 31,558 10,019 3,418 105° 33,300 25,641 7,659 2,740 105° 40,511 31,320 9,191 3,493 110° 32,050 24,679 7,372 2,785 110° 39,018 30,293 8,726 3,558 115° 30,800 23,716 7,084 2,830 115° 37,526 29,256 8,270 3,623 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 48 43,552 35,549 8,003 3,618 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 39,515 31,447 8,067 3,231 PERFORMANCE DATA ASXC160**1A* HIGH STAGE *SXC160241A* / CA*F3636*6**+TXV / MBVC1200**-1** Conditions: 80°F IDB, 67°F IW B @ 800 CFM, High Stage *SXC160361A* / CA*F3743*6**+TXV / MBVC1600**-1** Conditions: 80°F IDB, 67°F IWB @ 1200 CFM, High Stage Outdoor Te m p. ° F. Total Btuh Se ns ible Btuh Late nt Btuh Total Watts Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 25,200 17,951 7,249 1,694 75° 36,330 24,540 11,790 2,413 80° 24,900 17,963 6,937 1,749 80° 35,898 24,557 11,341 2,491 85° 24,600 17,969 6,631 1,805 85° 35,465 24,565 10,900 2,569 90° 24,300 18,036 6,264 1,853 90° 35,033 24,657 10,376 2,638 34,600 24,738 9,862 2,707 95° 24,000 18,096 5,904 1,902 95° 100° 23,400 17,978 5,422 1,943 100° 33,735 24,577 9,158 2,766 105° 22,800 17,843 4,957 1,985 105° 32,870 24,392 8,478 2,824 110° 21,960 17,257 4,703 2,020 110° 31,659 23,592 8,067 2,875 115° 21,120 16,666 4,454 2,056 115° 30,448 22,784 7,664 2,925 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 22,239 17,915 4,324 1,840 ASXC160481A* / CA*F4860*6**+TXV / MBVC2000**-1 Conditions: 80°F IDB, 67°F IW B @ 1600 CFM, High Stage 95° 32,062 24,491 7,571 2,620 *SXC160601A* / CA*F4961*6**+TXV / MBVC2000**-1** Conditions: 80°F IDB, 67°F IWB @ 1800 CFM, High Stage Outdoor Te m p. ° F. Total Btuh Se ns ible Btuh Late nt Btuh Total Watts Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 49,400 34,580 14,820 3,480 75° 59,850 43,108 16,742 4,443 80° 48,800 34,648 14,152 3,590 80° 59,138 43,137 16,001 4,587 85° 48,200 34,704 13,496 3,700 85° 58,425 43,152 15,273 4,731 90° 47,600 34,748 12,852 3,800 90° 57,713 43,312 14,400 4,857 95° 47,000 34,780 12,220 3,900 95° 57,000 43,456 13,544 4,984 100° 45,850 34,617 11,233 3,985 100° 55,575 43,172 12,403 5,092 105° 44,700 34,419 10,281 4,070 105° 54,150 42,848 11,302 5,199 110° 43,050 33,149 9,902 4,140 110° 52,155 41,442 10,713 5,292 115° 41,400 31,878 9,522 4,210 115° 50,160 40,023 10,137 5,385 TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 43,552 35,549 8,003 3,618 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 52,818 43,021 9,797 4,823 49 PERFORMANCE DATA ASXC160[24-60]1B* LOW STAGE *SXC160241B* / CA*F3636*6**+T XV +M BV C1200**-1* Conditions : 80°F IDB, 67°F IWB @ 540 CFM , L OW STAGE *SXC160361B* / CA*F3743*6**+TXV + MBVC1600**-1** Conditions: 80°F IDB, 67°F IWB @ 800 CFM, LOW STAGE Outd oor Te m p. ° F. Total Btu h Se ns ible Btu h Late n t Btuh Total Watts Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 18,480 12,396 6,084 1,220 75° 27,090 18,692 8,398 1,689 80° 18,260 12,404 5,856 1,260 80° 26,770 18,739 8,031 1,743 85° 18,040 12,409 5,631 1,300 85° 26,450 18,780 7,671 1,797 90° 17,820 12,455 5,365 1,335 90° 26,125 18,810 7,315 1,849 95° 17,600 12,496 5,104 1,370 95° 25,800 18,834 6,966 1,900 100° 17,160 12,414 4,746 1,400 100° 25,155 18,740 6,415 1,940 105° 16,720 12,321 4,399 1,430 105° 24,510 18,628 5,882 1,980 110° 16,104 11,917 4,187 1,455 110° 23,605 17,940 5,665 2,020 115° 15,488 11,509 3,979 1,481 115° 22,700 17,252 5,448 2,060 TV A Con dition s @ 95° OD DB, 75° ID DB, 63° ID WB 95° 16,300 12,388 3,912 1,310 *SX160481B* / CA*F4961*6** +TXV / MBVC2000**-1** Conditions: 80°F IDB, 67°F IWB @ 1100 CFM, LOW STAGE TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 23,556 17,943 5,613 1,832 *SXC160601B* / CA*F496*6**+T XV / M BV C2000**-1 ** Conditions : 80°F IDB, 67°F IWB @ 1400 CFM , L OW STAGE Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts Outd oor Te m p. ° F. Total Btu h Se ns ible Btu h Late n t Btuh Total Watts 75° 36,341 25,055 11,286 2,312 75° 42,700 29,463 13,237 2,810 80° 35,908 25,071 10,837 2,389 80° 42,200 29,540 12,660 2,905 41,700 29,607 12,093 3,000 85° 35,475 25,080 10,395 2,465 85° 90° 35,043 25,174 9,869 2,533 90° 41,150 29,628 11,522 3,085 40,600 29,638 10,962 3,170 95° 34,610 25,257 9,353 2,600 95° 100° 33,745 25,092 8,653 2,657 100° 39,600 29,502 10,098 3,240 105° 32,880 24,903 7,976 2,715 105° 38,600 29,336 9,264 3,310 37,200 28,458 8,742 3,375 35,800 27,566 8,234 3,440 110° 31,668 24,086 7,582 2,764 110° 115° 30,457 23,262 7,195 2,813 115° TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 50 32,071 25,004 7,067 2,515 TV A Con dition s @ 95° OD DB, 75° ID DB, 63° ID WB 95° 39,515 31,447 8,067 3,231 PERFORMANCE DATA ASXC160[24-60]1B* HIGH STAGE *SXC160241B* / CA*F3636*6**+TXV+MBVC1200**-1* Conditions: 80°F IDB, 67°F IWB @ 780 CFM, High Stage *SXC160361B* / CA*F3743*6** +TXV + MBVC1600**-1 Conditions: 80°F IDB, 67°F IWB @ 1200 CFM, High Stage Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 25,200 16,666 8,534 1,641 75° 36,750 25,358 11,393 2,490 80° 24,900 16,677 8,223 1,697 80° 36,315 25,421 10,895 2,570 35,880 25,475 10,405 2,650 35,440 25,517 9,923 2,725 85° 24,600 16,682 7,918 1,752 85° 90° 24,300 16,744 7,556 1,801 90° 95° 24,000 16,800 7,200 1,850 95° 35,000 25,550 9,450 2,800 34,125 25,423 8,702 2,860 100° 23,400 16,690 6,710 1,892 100° 105° 22,800 16,565 6,235 1,933 105° 33,250 25,270 7,980 2,920 110° 21,960 16,021 5,939 1,969 110° 32,025 24,339 7,686 2,975 115° 21,120 15,473 5,647 2,005 115° 30,800 23,408 7,392 3,030 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 22,200 16,650 5,550 1,770 *SXC160481B* / CA*F496*6**+TXV / MBVC2000**-1 Conditions: 80°F IDB, 67°F IWB @ 1550 CFM, High Stage 95° 32,062 24,491 7,571 2,620 *SXC160601B* / CA*F496*6**+TXV / MBVC2000**-1** Conditions: 80°F IDB, 67°F IW B @ 1800 CFM, High Stage Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts Outdoor Te m p. ° F. Total Btuh Se ns ible Btuh Late nt Btuh Total Watts 75° 49,350 35,621 13,729 3,328 75° 59,900 41,930 17,970 4,120 80° 48,763 35,644 13,118 3,437 80° 59,150 41,997 17,154 4,260 85° 48,175 35,657 12,518 3,547 85° 58,400 42,048 16,352 4,400 57,700 42,121 15,579 4,525 90° 47,588 35,789 11,798 3,644 90° 95° 47,000 35,908 11,092 3,741 95° 57,000 42,180 14,820 4,650 100° 45,825 35,674 10,151 3,823 100° 55,600 41,978 13,622 4,755 54,200 41,734 12,466 4,860 105° 44,650 35,405 9,245 3,906 105° 110° 43,005 34,244 8,761 3,977 110° 52,200 40,194 12,006 4,950 115° 41,360 33,071 8,289 4,048 115° 50,200 38,654 11,546 5,040 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 43,552 35,549 8,003 3,618 TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 52,818 43,021 9,797 4,823 51 PERFORMANCE DATA DSXC160[24-60]1A* LOW STAGE *SXC160241A* / CA*F3636*6**+TXV+MBVC1200**-1* Conditions: 80°F IDB, 67°F IWB @ 540 CFM, LOW STAGE *SXC160361A* / CA*F3743*6***+TXV + MBVC1600**-1** Conditions: 80°F IDB, 67°F IWB @ 800 CFM, LOW STAGE Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 18,480 12,396 6,084 1,220 75° 27,090 18,692 8,398 1,689 80° 18,260 12,404 5,856 1,260 80° 26,770 18,739 8,031 1,743 85° 18,040 12,409 5,631 1,300 85° 26,450 18,780 7,671 1,797 90° 17,820 12,455 5,365 1,335 90° 26,125 18,810 7,315 1,849 95° 17,600 12,496 5,104 1,370 95° 25,800 18,834 6,966 1,900 100° 17,160 12,414 4,746 1,400 100° 25,155 18,740 6,415 1,940 105° 16,720 12,321 4,399 1,430 105° 24,510 18,628 5,882 1,980 110° 16,104 11,917 4,187 1,455 110° 23,605 17,940 5,665 2,020 115° 15,488 11,509 3,979 1,481 115° 22,700 17,252 5,448 2,060 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 16,300 12,388 3,912 1,310 DSXC160481A* / CA*F4961*6A*+TXV / MBVC2000**-1 Conditions: 80°F IDB, 67°F IWB @ 1100 CFM, LOW STAGE TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 23,556 17,943 5,613 1,832 DSXC160601A* / CA*F4961*6**+TXV / MBVC2000**-1 Conditions: 80°F IDB, 67°F IWB @ 1400 CFM, LOW STAGE Outdoor Te m p. ° F. Total Btuh Se nsible Btuh Late nt Btuh Total Watts Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 36,800 25,760 11,040 2,340 75° 44,775 31,511 13,264 2,966 80° 36,350 25,809 10,542 2,415 80° 44,242 31,532 12,711 3,066 85° 35,900 25,848 10,052 2,490 85° 43,709 31,543 12,166 3,166 90° 35,450 25,879 9,572 2,555 90° 43,176 31,660 11,516 3,255 95° 35,000 25,900 9,100 2,620 95° 42,643 31,765 10,878 3,343 100° 34,150 25,783 8,367 2,680 100° 41,577 31,558 10,019 3,418 105° 33,300 25,641 7,659 2,740 105° 40,511 31,320 9,191 3,493 110° 32,050 24,679 7,372 2,785 110° 39,018 30,293 8,726 3,558 115° 30,800 23,716 7,084 2,830 115° 37,526 29,256 8,270 3,623 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 52 43,552 35,549 8,003 3,618 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 39,515 31,447 8,067 3,231 PERFORMANCE DATA DSXC160[24-60]1A* HIGH STAGE DSXC160241A* / CA*F3636*6**+TXV+MBVC1200**-1* Conditions: 80°F IDB, 67°F IWB @ 780 CFM, High Stage DSXC160361A* / CA*F3743*6** +TXV + MBVC1600**-1 Conditions: 80°F IDB, 67°F IWB @ 1200 CFM, High Stage Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 25,200 16,666 8,534 1,641 75° 36,750 25,358 11,393 2,490 80° 24,900 16,677 8,223 1,697 80° 36,315 25,421 10,895 2,570 85° 24,600 16,682 7,918 1,752 85° 35,880 25,475 10,405 2,650 90° 24,300 16,744 7,556 1,801 90° 35,440 25,517 9,923 2,725 35,000 25,550 9,450 2,800 95° 24,000 16,800 7,200 1,850 95° 100° 23,400 16,690 6,710 1,892 100° 34,125 25,423 8,702 2,860 105° 22,800 16,565 6,235 1,933 105° 33,250 25,270 7,980 2,920 32,025 24,339 7,686 2,975 30,800 23,408 7,392 3,030 110° 21,960 16,021 5,939 1,969 110° 115° 21,120 15,473 5,647 2,005 115° TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 22,200 16,650 5,550 1,770 DSXC160481A* / CA*F496*6**+TXV / MBVC2000**-1 Conditions: 80°F IDB, 67°F IWB @ 1550 CFM, High Stage Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 49,400 34,580 14,820 3,480 80° 48,800 34,648 14,152 3,590 85° 48,200 34,704 13,496 3,700 90° 47,600 34,748 12,852 3,800 95° 47,000 34,780 12,220 3,900 100° 45,850 34,617 11,233 3,985 105° 44,700 34,419 10,281 4,070 110° 43,050 33,149 9,902 4,140 115° 41,400 31,878 9,522 4,210 95° 43,552 35,549 8,003 3,618 24,491 7,571 2,620 DSXC160601A* / CA*F4861*6**+TXV / MVBC2000**-1 Conditions: 80°F IDB, 67°F IWB @ 1800 CFM, High Stage Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 80° 85° 90° 95° 100° 105° 110° 115° 59,850 59,138 58,425 57,713 57,000 55,575 54,150 52,155 50,160 43,108 43,137 43,152 43,312 43,456 43,172 42,848 41,442 40,023 16,742 16,001 15,273 14,400 13,544 12,403 11,302 10,713 10,137 4,443 4,587 4,731 4,857 4,984 5,092 5,199 5,292 5,385 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 32,062 95° 52,818 43,021 9,797 4,823 53 PERFORMANCE DATA DSXC160[48-60]1B* LOW STAGE DSXC160481A* / CA*F4961*6** +TXV / M BV C2000**-1B* Conditions : 80°F IDB, 67°F IWB @ 950 CFM , LOW STAGE DSXC160601B* / CA*F496*6**+TXV / M BV C2000**-1 ** Conditions : 80°F IDB, 67°F IWB @ 1400 CFM , LOW STAGE Outdoor Te m p. ° F. Total Btuh Se ns ible Btuh Late nt Btuh Total Watts Outdoor Te m p. ° F. Total Btuh Se ns ible Btuh Late nt Btuh Total Watts 75° 36,750 24,304 12,446 2,067 75° 42,700 29,463 13,237 2,810 42,200 29,540 12,660 2,905 80° 36,313 24,320 11,993 2,182 80° 85° 35,875 24,329 11,547 2,297 85° 41,700 29,607 12,093 3,000 90° 35,438 24,419 11,018 2,399 90° 41,150 29,628 11,522 3,085 40,600 29,638 10,962 3,170 95° 35,000 24,500 10,500 2,500 95° 100° 34,125 24,340 9,785 2,586 100° 39,600 29,502 10,098 3,240 105° 33,250 24,157 9,093 2,672 105° 38,600 29,336 9,264 3,310 37,200 28,458 8,742 3,375 35,800 27,566 8,234 3,440 110° 32,025 23,364 8,661 2,747 110° 115° 30,800 22,565 8,236 2,821 115° TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 32,071 25,004 7,067 95° 2,515 39,515 31,447 8,067 3,231 DSXC160[48-60]1B* HIGH STAGE DSXC160481B* / CA*F4961*6**+TXV / MBVC2000**-1 Conditions: 80°F IDB, 67°F IWB @ 1550 CFM, High Stage *SXC160601B* / CA*F496*6**+TXV / MBVC2000**-1** Conditions: 80°F IDB, 67°F IW B @ 1800 CFM, High Stage Outdoor Te m p. ° F. Total Btuh Se ns ible Btuh Late nt Btuh Total Watts 75° 59,900 41,930 17,970 4,120 80° 59,150 41,997 17,154 4,260 85° 58,400 42,048 16,352 4,400 3,660 90° 57,700 42,121 15,579 4,525 95° 57,000 42,180 14,820 4,650 Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 49,350 35,434 13,916 3,331 80° 48,763 35,457 13,305 3,445 85° 48,175 35,470 12,705 3,559 90° 47,588 35,602 11,986 95° 100° 47,000 45,825 35,720 35,487 11,280 10,338 3,760 3,845 100° 55,600 41,978 13,622 4,755 105° 44,650 35,220 9,430 3,931 105° 54,200 41,734 12,466 4,860 110° 115° 43,005 41,360 34,064 32,898 8,941 8,462 4,005 4,078 110° 52,200 40,194 12,006 4,950 115° 50,200 38,654 11,546 5,040 TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 22,200 16,650 5,550 1,770 TV A Conditions @ 95° OD DB, 75° ID DB, 63° ID WB 95° 52,818 43,021 9,797 4,823 PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side pressures and power. A properly operating unit should be within the subcooling value shown in the Air Conditioner Specifications. A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown. A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown. A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown. A properly operating unit should be within plus or minus 3 Amps of the typical value shown. NOTE: Pressures are measured at the liquid and suction service valve ports. 54 S OAS DT R C YL CS CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. COMPONENT CODE C --------------- CONTACTOR CM ------------ CONDENSER FAN MOTOR COMP -------- COMPRESSOR CS ------------- COMPRESSOR SOLENOID HPS ----------- HIGH PRESSURE SWITCH IO -------------- INTERNAL OVERLOAD LPS ---------- LOW PRESSURE SWITCH OAS ----------- OUTDOOR AIR SENSOR RCCF --------- RUN CAPACITO R FOR COMPRESSOR & FAN SC ------------- STAR T CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- STAR T RELAY FOR COMPRESSOR (OPTIONAL) CH ------------ CRANKCASE HEATER (OPTIONAL) CHS ---------- CRANKCASE HEATER SWITCH (OPTIONAL) SEE NOTE 1 C AUX COMP MAIN RD RD NOTE 2 BK BK LPS RD BL/PK HPS R HIGH VOLTAGE AREA BK BK SC OPTIONAL HARD START 1 SR 2 5 NOTE 4 RUN CAPACITOR CM C CAP CH C CHS K2 C COMP C R S S HERM HERM FAN COM IO BK NOTE 4 H RCCF CH PU BR BK (HIGH) RD (LOW) LOW CAP K3 UC CONTROL PSC FAN MOTOR AUX C F YL BR RD BL/PK 2 RES LPS CS E14 OAS HPS LOW VOLTAGE AREA 5 OPTIONAL HARD START SR SC 1 PU E22 MAIN E23 E24 GR/YL HIGH K4 CHS K6 DT BK --------------- BLACK BL --------------- BLUE BL/PK ---------- BLUE/PINK STRIPE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW YL/PK ---------- YELLOW/PINK STRIPE L1 L2 E26 E47 COLOR CODE E29 YL RD O L Y2 Y1 W1 C R 2 1 E2 FROM OUTDOOR UNIT L2 L1 L1 L2 E13 L2 OUT YL RELAY E16 RELAY CH E21 RELAY START RLY CAP COM E17 E11 C R O L (OPTIONAL) Y2 Y1 W1 C R C R 2 1 E47 OCT E2 O L Y2 Y1 W1 C R 2 1 C R 1 2 E25 FUSE RELAY NOTE 2 GND C R 2 1 OPTIONAL LOW VOLTAGE OPTIONAL HIGH VOLTAGE HIGH VOLTAGE FIELD LOW VOLTAGE HIGH VOLTAGE WIRING CODE FACTORY WIRING BL RD YL PU LOW VOLTAGE BARRIER 1. IF DT IS NOT PRESENT, HPS BL/PK WIRE GOES DIRECTLY TO TERMINAL E29. 2. USE COPPER SUPPLY WIRES ONLY. 3. USE 40VA TRANSFORMER MINIMUM. 4. CRANKCASE HEATER FACTORY INSTALLED OPTION. NOTES: CONTROL BOX TO INDOOR COMMUNICATING PCB INDOOR POWER SUPPLY 24 VAC 0140R00138-F THIS WIRING SCHEMATIC SHOWS THE LEGACY WIRING FROM THE FACTORY. THE WIRES GO TO INDOOR T-STAT AS SHOWN IN "LEGACY INDOOR T-STAT". TO WIRE THE SYSTEM IN COMMUNICATING MODE, THE INSTALLER HAS TO WORK THE WIRING AS SHOWN IN "COMMUNICATING INDOOR T-STAT". REFER TO THE IO MANUAL LOCATED IN COMMUNICATING T-STAT KIT FOR MORE DETAILS. OAT UC BOARD E1 LPCO HPCO RELAY E22 E23 INDOOR POWER SUPPLY 24 VAC E14 HIGH FAN RUN E24 E26 E28 E29 COMMUNICATING INDOOR T-STAT FROM OUTDOOR UNIT O L Y2 Y1 W1 C R LEGACY INDOOR T-STAT E8 R RUN RD C E5 START E10 HERM RD BK COM START YL/PK YL/PK 230 VAC SUPPLY RD BK BK BK 3 6 E28 1 4 E1 WIRING DIAGRAMS *SXC160[24-60]1A*/B* HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 55