Preview only show first 10 pages with watermark. For full document please download

Technical Manual

   EMBED


Share

Transcript

R410A50Hz Universal Outdoor Series Technical Manual Outdoor Unit R410A 50Hz Universal Outdoor Series Inverter type Technical Manual 2014 Version LCAC/1.0/201401 I GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Content PART 1.General Information ..................................................................................... 1 1. Nomenclature ....................................................................................................... 2 2. Model Names of Indoor/Outdoor Units ................................................................ 3 3. External Appearance............................................................................................ 4 4. Features ............................................................................................................... 6 Part 2 Indoor Unit....................................................................................................... 7 4-Way Cassette Type ...................................................................................................... 7 1. Features ............................................................................................................... 8 2. Specification ....................................................................................................... 11 3. Dimension .......................................................................................................... 13 4. Service Space .................................................................................................... 15 5. Wiring Diagrams ................................................................................................ 16 6. Capacity Table.................................................................................................... 17 7. Electric Characteristics ...................................................................................... 20 8. Exploded View ................................................................................................... 21 9. Accessories ........................................................................................................ 25 10. The Specification of Wiring .............................................................................. 26 11. Field Wiring ...................................................................................................... 27 12. Trouble shooting .............................................................................................. 29 Duct Type .................................................................................................................... 30 1. Features ............................................................................................................. 31 2.Specification ........................................................................................................ 35 3. Dimensions ........................................................................................................ 37 4. Service Space .................................................................................................... 38 5. Wiring Diagrams ................................................................................................ 39 6. Capacity Tables .................................................................................................. 42 7. Static Pressure................................................................................................... 44 8.Electric Characteristics ....................................................................................... 46 9. Accessories ........................................................................................................ 47 10.The Specification of Wiring ............................................................................... 48 11.Field Wiring ....................................................................................................... 49 12. Exploded View ................................................................................................. 50 13. Trouble shooting .............................................................................................. 53 Floor & Ceiling ............................................................................................................ 54 1.Features .............................................................................................................. 55 2. Specifications ..................................................................................................... 57 3.Dimensions ......................................................................................................... 59 4.Service Space ..................................................................................................... 60 5.Wiring Diagrams ................................................................................................. 61 6.Capacity Table..................................................................................................... 62 7.Electric Characteristics ....................................................................................... 64 8. Exploded View ................................................................................................... 65 II GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 9.Accessories ......................................................................................................... 67 10.The Specification of Power ............................................................................... 68 11.Field Wiring ....................................................................................................... 69 12.Troubleshooting ................................................................................................ 70 Part 3 Outdoor Units................................................................................................ 71 1.Specification ........................................................................................................ 72 2.Dimensions ......................................................................................................... 74 3.Service Space ..................................................................................................... 76 4.Wiring Diagrams ................................................................................................. 77 5.Electric Characteristics ....................................................................................... 79 6.Operation Limits .................................................................................................. 80 7.Sound Levels ...................................................................................................... 81 8.Exploded View .................................................................................................... 82 9.Troubleshooting .................................................................................................. 89 Part 4 Installation ..................................................................................................... 91 1. Precaution on Installation .................................................................................. 92 2.Vacuum Dry and Leakage Checking .................................................................. 93 3.Additional Refrigerant Charge ............................................................................ 95 4.Water Drainage ................................................................................................... 96 5.Insulation Work ................................................................................................... 99 6. Test Operation .................................................................................................. 101 Part 5 Controller..................................................................................................... 102 1.Wireless Remote Controller .............................................................................. 103 2.Wire Controller .................................................................................................. 106 III GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual R410A 50Hz Universal Outdoor series PART 1.General Information 1.Nomenclature ..................................................................................... 2 2.Model Names of Indoor/Outdoor Units ............................................... 3 3.External Appearance .......................................................................... 4 4.Features ............................................................................................. 6 1 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 1. Nomenclature 1.1 Indoor unit C CA T i - 2 E C V R1 - B Design No Refrigerant -:R22; R1:R410A V:DC Inv. -:Fixed speed. Function code E:Electrical auxiliary heater. Capacity,unit:kBtu/h -:Match universal outdoor unit; i:match individual outdoor Working Condition -:T1 condition; T:T3 condition. Product series CA:4-way cassette; CB:Compact 4-way Casssette TA;Low ESP Duct; TB:Mid ESP Duct; TH:High ESP Duct;UA:Floor & C:Chigo HVAC 1.2 Outdoor unit C 3 O T - 2 C S V R1 - B Design No Refrigerant V:DC Inv. Power Code Function code Capacity,unit:kBtu/h Working Condition Product series Match Code C:Chigo HVAC 2 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 2. Model Names of Indoor/Outdoor Units 2.1 Indoor Units Model name Dimension (W×H×D) (mm) Net/Gross weight(kg) Power supply CCA-18HVR1 CCA-24HVR1 CCA-36HVR1 840×230×840 840×230×840 840×285×840 25/30 24/30 30.5/36 220~240V-1Ph-50Hz 220~240V-1Ph-50Hz 220~240V-1Ph-50Hz CTA-18HVR1 CTA-24HVR1 CTB-36HVR1 1100×467×210 1100×467×210 1425×663×260 22.5/25.5 25/28 46/50 220~240V-1Ph-50Hz 220~240V-1Ph-50Hz 220~240V-1Ph-50Hz CUA-18HVR1 CUA-24HVR1 CUA-36HVR1 1245×680×244 1245×680×244 34/40 34/40 35/41 220~240V-1Ph-50Hz 220~240V-1Ph-50Hz 220~240V-1Ph-50Hz 1245×680×244 2.2 Outdoor Units Model name COU-18HDR1 COU-24HDR1 COU-36HDR1 3 Dimension (W×H×D) (mm) 930×370×700 960×390×835 911×400×1335 Net/Gross weight(kg) 45/49 59/69 96/101 Power supply 220~240V-1Ph-50Hz 220~240V-1Ph-50Hz 220~240V-1Ph-50Hz GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 3. External Appearance 3.1 Indoor unit 4-way Cassette Low ESP Duct Middle ESP Duct Floor & Ceiling 4 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 3.2 Outdoor unit COU-18HDR1 COU-24HDR1 COU-36HDR1 5 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 4. Features 4.1 Wide operation range, -5 for cooling and -15 for heating. 4.2 Excellent in efficiency, SCOP higher than 3.8, meet the EU’s new energy efficiency standards. 4.3 High quality coils The coil is constructed of advanced inner grooved copper tube and aluminum fins. 4.4 Low operation sound level: Well-known stable and quiet running DC fan motor. 4.5 Well-known compressor, GMCC and Mitsubishi. 4.6 Universal design: convenient for market stock and spare parts stock. 4.8 R410A environment friendly refrigerant. 4.9 CE certification, ROHS certification. 6 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Part 2 Indoor Unit 4-Way Cassette Type 1. Features ............................................................................................. 8 2. Specification ...................................................................................... 11 3. Dimension ....................................................................................... 13 4. Service Space .................................................................................. 15 5. Wiring Diagrams .............................................................................. 16 6. Capacity Table ................................................................................. 17 7. Electric Characteristics .................................................................... 20 8. Exploded View ................................................................................. 21 9. Accessories ..................................................................................... 25 10. The Specification of Wiring ............................................................ 26 11. Field Wiring .................................................................................... 27 12. Trouble shooting ............................................................................ 29 7 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Features (1) Brand-new panel design. Indoor unit use uniform panel, simple and convenient. (2) Simple, featly and voguish appearance suit for different requirements, it’s mostly used for office, shopping center, restaurant, meeting room and etc. 18kBtu/h~60kBtu/h, standard type, 950mm*950mm (3) Ultra-thin body design, the min. height is only 230mm, save installation space. (4) 4-way air flow, cold air can reach each corner of the room, providing a stable and comfortable environment. (5) Intelligent auto-swing function, three modes for choice. Standard mode 8 Anti-point blow mode Ceiling against mode GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual (6) 3 fan speed,meet for different requirement. (7) New streamlined fan design. (8) Occupied a small installation space, saving interior space (9) Easy and convenient installation and maintenance, washable filter design. (10) Built-in water pump, water head up to 1200mm. 9 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual (11) Integrated electric control box, The E-box is safely covered by metal plate, for better fire-resistance, save using. (12) Add 4 interfaces in body, can be connected with duct to another room. Fresh air makes air quality more healthy and comfortable. (13) (14) (15) Multi protection and auto-restart function. Low operation sound level: Well-known stable and quiet running DC fan motor. Standard for wireless controller; option for wired controller. Standard 10 optional GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 1. Specification Model CCA-18HVR1 CCA-24HVR1 CCA-36HVR1 V/Ph/Hz 220~240/1/50 220~240/1/50 220~240/1/50 KW 2.0-5.3-5.6 3.5-7.0-8.0 6.6-10.5-12.8 Power input W 420-1840 600-3000 1050-4600 Current input A 1.8-7.8 2.5-13 4.2-24.8 SEER W/W 5.6 5.6 5.1 Capacity KW 3.0-5.3-6.0 4.5-7.0-8.5 7.35-10.5-13.2 Input W 640-1640 1500-2600 1100-4150 Rated current A 3-8.0 5.5-11 4.4-18.5 W/W 4.0 4.0 3.8 Energy rate Cooling A+ A+ A Energy rate Heating A+ A+ A+ Max. power input W 2000 3200 4800 Max. current input A 10 14 26 Model DR-310-60Q-8 DR-310-60Q-8 DR-310-100Q-8 Brand Panasonic Panasonic Panasonic W 60 60 100 r/min 850 850 840/750/650 Insulation class E E E Number of rows Tube pitch(a) x row pitch(b) Fin spacing 2 2 2 mm 21×13.37 21×13.37 21×13.37 mm 1.45 1.45 1.45 Hydrophilic Hydrophilic Hydrophilic Ф7 Ф7 Ф7 inner grooved inner grooved inner grooved 2000×168×26.7 2000×168×26.74 2000×252×26.74 Indoor power supply Capacity Cooling Heating SCOP Indoor fan motor Power output Speed Indoor coil Fin type Tube outside dia. and type Coil length x height x width Number of circuits mm mm 8 8 12 Indoor air flow(High speed) 3 m /h 900 1100 1800 Indoor noise level dB(A) 46~58 56~63 53~61 Body(mm) 840×840×230 840×840×230 840×840×285 Panel(mm) 950×950×50 950×950×50 950×950×50 Body(mm) 985×920×265 985×920×265 920×920×310 Panel(mm) 1030×1030×105 1030×1030×105 1030×1030×105 Body(Kg) 25/30 24/30 30.5/36 Panel(Kg) 5.4/8.0 5.4/8.0 5.4/8.0 MPa 3.8 3.8 3.8 Dimension(W*H*D) Indoor unit Packing(W*H*D) Net/Gross weight Max pressure 11 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Refrigerant type Refrigerant Liquid side/Gas side piping Drainage pipe R410A R410A R410A mm Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 mm DN25 DN25 DN25 Standard controller Standard for remote controller(wired controller for option) Operation temp °C 16~32 16~32 16~32 Ambient temp °C -5~50 -5~50 -5~50 cooling Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. Piping: 7.5m(horizontal) 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 7.5m(horizontal) 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. 12 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 3. Dimension 3.1 CCA-18HVR1, CCA-24HVR1 13 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 3.2 CCA-36HVR1 14 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 4. Service Space The indoor unit should be installed in a location that meets the following requirements: 4.1 There is enough interspace for installation and maintenance. 4.2 The ceiling is horizontal, and its structure can endure the weight of the indoor unit. 4.3 The outlet and the inlet are not impeded, and the influence of external air is the least. 4.4 The air flow can reach throughout the room. 4.5 The connecting pipe and drainpipe could be extracted out easily. 4.6 There is no direct radiation from heaters. 15 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 5. Wiring Diagrams CCA-18HVR1 CCA-24HVR1 CCA-36HVR1 Indoor models Select bits ON Note:Model 10.5 kw ground does not need to connect outdoor Indoor models SW2 NO.1,2 Low static pressure duct unit OFF 1 2 ON Ceiling cassette unit OFF 1 2 ON Standard static pressure duct unit OFF 1 2 ON Connect to the outdoor Floor&Ceiling unit OFF 1 2 Receive and display light board ON L1 N1 S LED OFF 4 ON Digital tube OFF 4 SW2 NO.8 Heating fan stop time SW2 NO.5 ON power-down memory OFF 5 4MIN OFF 8 ON No power-down memory OFF 5 SW2 NO.6 ON ON 8MIN OFF 8 Heating temperature compensation SW2 NO.7 ON 6℃ OFF 6 ON ON OFF 7 ON 2℃ OFF 6 Anti-cold wind off the fan temperature selection bit OFF 7 15℃ NOTE: L N SW2 NO.4 ON OFF 1 That DIP to ON ON OFF 1 That DIP to Digital 24℃ SW2 ON HP POWER SW1 16 2 53 0 2 53 1 2 53 2 2 53 3 2 3 53 70 4 5 3 4 4 4 70 105 105 105 6 7 9 8 OFF 1234 567 8 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 6. Capacity Table Cooling 6.1 CCA-18HVR1 MODEL COOLING Indoor Conditions Total capacity kW 21ºC D Sensitive capacity kW 15ºC W Input kW. Total capacity kW 24ºC D Sensitive capacity kW 17ºC W Input kW. Total capacity kW 27ºC D Sensitive capacity kW 19ºC W Input kW. Total capacity kW 29ºC D Sensitive capacity kW 19ºC W Input kW. Total capacity kW 32ºC D Sensitive capacity kW 23ºC W Input kW. 21ºC 5.15 4.13 1.0 5.59 4.52 1.06 6.23 5.12 1.09 6.39 5.27 1.21 6.98 5.52 1.3 CCA-18HVR1 OUTDOOR TEMPERATURE DRY 28ºC 35ºC 4.85 4.49 3.91 3.58 1.29 1.49 5.31 4.91 4.25 3.89 1.3 1.57 5.42 5.32 4.61 4.23 1.67 1.69 5.85 5.57 4.75 4.47 1.71 1.93 6.11 5.83 4.92 4.68 1.89 2.18 43ºC 4.21 3.38 1.75 4.61 3.71 1.83 5.01 4.01 1.96 5.33 4.28 2.16 5.78 4.55 2.25 21ºC 7.34 5.42 2.14 7.57 5.68 2.28 7.71 5.71 2.31 7.76 6.54 2.36 7.84 6.63 2.42 CCA-24HVR1 OUTDOOR TEMPERATURE DRY 28ºC 35ºC 7.05 6.68 5.44 5.32 2.32 2.47 7.23 6.83 5.62 5.61 2.47 2.56 7.37 7.18 5.66 5.6 2.45 2.56 7.43 7.16 6.32 6.26 2.52 2.65 7.61 7.42 6.60 6.40 2.53 2.72 43ºC 6.41 5.39 2.55 6.43 5.41 2.67 6.69 5.45 2.71 6.71 6.15 2.73 6.88 6.37 2.82 6.2 CCA-24HVR1 MODEL COOLING Indoor Conditions Total capacity kW 21ºC D Sensitive capacity kW 15ºC W Input kW. Total capacity kW 24ºC D Sensitive capacity kW 17ºC W Input kW. Total capacity kW 27ºC D Sensitive capacity kW 19ºC W Input kW. Total capacity kW 29ºC D Sensitive capacity kW 19ºC W Input kW. Total capacity kW 32ºC D Sensitive capacity kW 23ºC W Input kW. 17 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 6.3 CCA-36HVR1 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 29ºC D 19ºC W 32ºC D 23ºC W MODEL COOLING Indoor Conditions Total capacity kW Sensitive capacity kW Input kW. Total capacity kW Sensitive capacity kW Input kW. Total capacity kW Sensitive capacity kW Input kW. Total capacity kW Sensitive capacity kW Input kW. Total capacity kW Sensitive capacity kW Input kW. 21ºC 10.92 8.08 3.11 11.19 8.40 3.29 11.38 8.42 3.36 11.51 9.67 3.39 11.59 9.82 3.54 CCA-36HVR1 OUTDOOR TEMPERATURE DRY 28ºC 35ºC 10.32 9.81 7.98 7.84 3.38 3.52 10.66 10.14 8.29 8.23 3.52 3.67 10.92 10.55 8.40 8.19 3.56 3.63 11.03 10.74 9.32 9.28 3.62 3.77 11.18 11.03 9.71 9.71 3.67 3.96 43ºC 9.38 7.89 3.61 9.52 8.01 3.88 9.75 7.19 4.10 9.91 9.00 3.98 10.11 9.37 4.09 Heating 6.4 CCA-18HVR1 MODEL HEATING Indoor Conditions 15ºC 18ºC 20ºC 22ºC 27ºC 18 Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. 24ºC D 18ºC W 9.92 2.95 9.31 2.83 8.61 2.58 7.92 2.41 6.91 2.11 CCA-18HVR1 OUTDOOR CONDITIONS 7ºC D 2ºC DB -5ºC D 6ºC W 1ºC WB -6ºC W 6.62 5.81 4.97 2.01 1.82 1.71 6.22 5.45 4.68 1.88 1.74 1.61 5.89 5.05 4.29 1.65 1.61 1.48 5.32 4.66 4.03 1.58 1.48 1.38 4.63 4.05 3.48 1.38 1.29 1.19 -7ºC D -8ºC W 4.64 1.61 4.38 1.51 4.04 1.40 3.73 1.23 3.27 1.11 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 6.5 CCA-24HVR1 MODEL HEATING Indoor Conditions 15ºC 20ºC 27ºC Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. 24ºC D 18ºC W 10.32 2.31 10.03 2.41 9.41 2.58 CCA-24HVR1 OUTDOOR CONDITIONS 7ºC D 2ºC DB -5ºC D 6ºC W 1ºC WB -6ºC W 8.17 6.85 6.19 2.06 2.0 1.88 7.88 6.43 6.08 2.07 2.05 1.97 7.53 6.11 5.89 2.17 2.11 2.05 -7ºC D -8ºC W 5.84 1.77 5.59 1.87 5.27 1.98 24ºC D 18ºC W 15.22 3.57 14.75 3.87 13.79 4.39 CCA-36HVR1 OUTDOOR CONDITIONS 7ºC D 2ºC DB -5ºC D 6ºC W 1ºC WB -6ºC W 12.31 10.12 9.14 3.15 2.98 2.85 11.63 9.41 8.85 3.18 3.1 2.98 10.94 8.86 8.64 3.55 3.46 3.33 -7ºC D -8ºC W 8.46 2.65 8.21 2.87 7.72 3.07 6.6 CCA-36HVR1 MODEL HEATING Indoor Conditions 15ºC 20ºC 27ºC 19 Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 7. Electric Characteristics Model Indoor Units Indoor Fan Motor Hz Voltage Min. Max. kW CCA-18HVR1 50 220-240V 198V 254V 0.06 CCA-24HVR1 50 220-240V 198V 254V 0.06 CCA-36HVR1 50 220-240V 198V 254V 0.10 20 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 8. Exploded View 8.1 CCA-18HVR1,CCA-24HVR1 21 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual No. Part Name No. Part Name 1 E-parts box cover 8.4.2 Evaporator 2 Electric control components for indoor unit 8.4.3 collecting pipe welding assy 2.1 E-parts board for indoor unit 8.4.4 Current divider capillary assy 2.2 Temperature sensor 8.5 Main fixing board 2.3 Terminal 9 Upper foam components 2.4 Terminal 10 Pre-assembling assy for water pump 2.5 Relay 10.1 water pump support 2.6 Welded chassis for E-parts box 10.2 Water pump 3 Wind inlet guide assy 10.3 Liquid-level sensor 3.1 Wind inlet guide 10.4 Underlay for water pump support 4 Water pan components 11 Hanger 4.1 Foam pendant 12 Rear brattice 5 Centrifugal fan 13 Chassis assy 6 Fan motor for indoor unit 14 Discharge pipe joint 7 Auxiliary fixing board for evaporator 15 Side maintenance board for water pump 8 Evaporator components 16 Front brattice 8.1 Insulating pipe 17 Lower pipe clamp 8.2 Insulating pipe 18 Lower pipe clamp(φ35) 8.3 Evaporator attached cotton 19 Upper pipe clamp 8.4 Evaporator welding assy 20 Upper pipe clamp(φ35) 21 Valve panel 8.4.1 Installation tube for probe 22 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 8.2 CCA-36HVR1 23 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual No. Part Name No. Part Name 1 E-parts box cover 8.4.2 Evaporator 2 Electric control components for indoor unit 8.4.3 collecting pipe welding assy 2.1 The electric control board base 8.4.4 Current divider capillary assy 2.2 relay 8.5 Main fixing board 2.3 Terminal 9 The chassis plate 2.4 Terminal 10 Upper foam components 2.5 E-parts board for indoor unit 11 Pre-assembling assy for water pump 2.6 Temperature sensor 11.1 water pump support 2.7 Temperature sensor 11.2 Water pump 2.8 Welded chassis for E-parts box 11.3 Liquid-level sensor 3 Wind inlet guide assy 11.4 Underlay for water pump support 3.1 Wind inlet guide 12 Hanger 4 Water pan components 13 Rear brattice 4.1 Foam pendant 14 Chassis assy 5 Centrifugal fan 15 Discharge pipe joint 6 Fan motor for indoor unit 16 Side maintenance board for water pump 7 Auxiliary fixing board for evaporator 17 Front brattice 8 Evaporator components 18 Lower pipe clamp 8.1 Insulating pipe 19 Lower pipe clamp(φ35) 8.2 Insulating pipe 20 Upper pipe clamp 8.3 Evaporator attached cotton 21 Upper pipe clamp(φ35) 8.4 Evaporator welding assy 22 Valve panel 8.4.1 Installation tube for probe 24 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 9. Accessories Name Installation Fittings Tubing & Fittings (optional) Drainpipe Fittings Protect Pipe Fittings (optional) Remote controller Others 25 Shape Quantity Expansible hook 4 Installation hook 4 Installation paper board 1 Bolt M5 4 Connecting pipe group 1 Binding tape 1 Soundproof/insulation sheath 2 Out-let pipe sheath 1 Tightening band 5 Wall conduit 1 Wall conduit cover 1 Remote controller 1 Mounting screw(ST2.9×10-C-H) 2 Alkaline dry batteries (AM4) 2 Operation & installation instruction manual 1 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 10. The Specification of Wiring Model 18kBtu/h 24kBtu/h Indoor power supply V/Ph/Hz 220~240/1/50 Outdoor power supply V/Ph/Hz 220~240/1/50 mm 2 3×2.5 3×2.5 Power supply individually for indoor and outdoor 3×1.5/3×4.0 mm 2 4×2.5 4×2.5 3×1.0 Outdoor Power Supply Connection wiring Power wiring Signal wiring 26 36kBtu/h From indoor unit From indoor unit GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 11. Field Wiring 27 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 28 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 12. Trouble shooting Fault codes table 29 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Duct Type 1. Features ........................................................................................... 31 2.Specification ..................................................................................... 35 3. Dimensions ...................................................................................... 37 4. Service Space .................................................................................. 38 5. Wiring Diagrams .............................................................................. 39 6. Capacity Tables ............................................................................... 42 7. Static Pressure ................................................................................ 44 8.Electric Characteristics ..................................................................... 46 9. Accessories ..................................................................................... 47 10.The Specification of Wiring ............................................................. 48 11.Field Wiring ..................................................................................... 49 12. Exploded View ............................................................................... 50 13. Trouble shooting ............................................................................ 53 30 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 1. Features Low Static Pressure Duct Medium Static Pressure Duct 31 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 1.1 Low ESP Ducted Unit 1. Short body, min. 700 mm width, easy to install. 2. Adopting aviation centrifugal fans, and CFD technology design, increasing air-volume and decreasing noise level. 3. Three fan speed, meet different requirement. 4. High efficiency DC fan motor, low noise and more comfortable. 5. E-box is body-side design, convenient installation and maintenance. 6. Standard for wireless remote controller, wired controller for option. Standard 32 optional GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 1.2 Medium ESP Ducted Unit 1. Ultra-thin body design. 2. Adopting aviation centrifugal fans, and CFD technology design, increasing air-volume and decreasing noise level. 3. Three fan speed, meet different requirement. 4. 30-50Pa ESP design for the medium static pressure duct type, duct connected installation meet for different room structure. 5. Filter can be taken out easily for clear. Easy maintenance. 6. E-box is body-side design, convenient installation and maintenance. 33 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 7. High efficiency DC fan motor, low noise and more comfortable. 8. Two air return type option: air inlet from back is standard and from bottom is optional 9. Multi protection and auto-restart function. 10. Standard for wireless remote controller, wired controller for option. Standard 34 optional GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 2. Specification Model KW CTA-18HVR1 220~240V/1Ph/50H z 2.0-5.3-5.6 CTA-24HVR1 220~240V/1Ph/5 0Hz 3.5-7.0-8.0 CTB-36HVR1 220~240V/1Ph/50 Hz 6.6-10.5-12.8 Power input W 420-1840 650-3050 1150-4760 Current input A 1.8-7.8 2.8-13.3 4.7-25.3 SEER W/W 5.5 5.5 5.1 Capacity KW 3.0-5.3-6.0 4.5-7.0-8.5 7.35-10.5-13.2 Input W 640-1640 1550-2650 1200-4250 Rated current A 3.0-8.0 5.8-11.3 4.9-19 W/W 3.8 3.8 3.8 Energy rate Cooling A A A Energy rate Heating A A A Max. power input W 2000 3250 4800 Max. current input A 10 14.5 Model DR-310-68F-8 DR-310-68F-8 26 DR-310-150F-8 + DR-310-75F-8 Brand Panasonic Panasonic Panasonic W 68 68 150+75 μF - - r/min 1275/1080/880/720 1275/1080/880/7 20 E E 1350/1240/1140/1 040 + 1350/1270/1200/1 130 E 2*2 2*2 3 mm 20×19.05 20×19.05 22×19.05 mm 1.4 1.4 1.7 Hydrophilic Hydrophilic Hydrophilic Ф7 Ф7 Ф7.94 inner grooved inner grooved Indoor power supply Capacity Cooling Heating SCOP Indoor fan motor Power output Capacitor Speed V/Ph/Hz Insulation class Number of rows Tube pitch(a) x row pitch(b) Fin spacing Fin type Indoor coil Tube outside dia. and type mm 4 5 3 m /h 800 1050 1800 Pa 0-30 0-30 30-50 dB(A) 46~58 56~63 55~63 Dimension(W*H*D) Body(mm) 1100×467×210 1100×467×210 1425×663×260 Packing(W*H*D) Body(mm) 1310×240×510 1310×240×510 1490×720×325 Net/Gross weight Body(Kg) 22.5/25.5 25/28 46/50 Coil length x height x width mm Number of circuits Indoor air flow(High speed) Static Pressure Indoor noise level Indoor unit 35 inner grooved 1136×240×57.1 5 6 920×200×46 920×200×46 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Max pressure Refrigerant type Refrigerant Liquid side / piping Gas side Drainage pipe MPa 3.8 3.8 3.8 R410A R410A R410A mm Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 mm DN25 DN25 DN25 Standard controller Standard for remote controller(wired controller for option) Operation temp °C 16~32 16~32 16~32 Ambient temp °C -5~50 -5~50 -5~50 cooling Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. Piping: 7.5m(horizontal) 2.Nominal heating capacities are based on the following conditions: Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 7.5m(horizontal) 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. 36 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 3. Dimensions 3.1 CTA-18HVR1 CTA-24HVR1 3.2 CTB-36HVR1 37 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 4. Service Space Ensure enough space required for installation and maintenance. 38 GD Chigo Heating & Ventilation Equipment Co., Ltd. ALARM S CN37 CN27 Wi re control T1 T2 T 2B L1 N1 S COMMUNICATION Line pressing buttons OUT POWER CN11 CN23 Duct display L N POWER T1 Line pressing buttons That DIP to ON SW2 1 2 3 4 5 6 7 8 COM NO J PUMP PUMP 1 NOTE: ON OFF That DIP to Digital OFF ON FACTORY DEFAULT 1 C10 BR BK ON OFF IC4 ALARM S CN37 SW1 4 4 4 105 105 105 7 9 8 SW2 3 70 6 CN26 CN4 HEATER REM O_CT RL 3 70 5 N RY6 5 CN27 Wire control 2 53 4 L CN3 T1 T2 T2B CN17 2 53 3 CN1 RD COM SW2 1 2 3 4 5 6 7 8 OFF ON PT1 CN18 Water-SW LEFT FAN CN7 IC2 2 53 2 YE/GN Connect to the outdoor L1N1 S NO OUT POWER CN11 PT2 BR BK BK F01 PT3 2 53 1 PUMP Controller BR L N POWER INPUT CN26 REMO_CTRL WATER SWITCH 5 DC FAN YE/GN PTC 10 C10 IC4 RY4 CN23 Duct display RIGHT FAN CN8 E21 T1 Receive and display light board 2 53 0 The power (PH) of indoor units can be set throughDIP switch SW1(16- bit disc DIP ) on the indoor control panel before delivery, the detailed information is as follows: HP POWER SW1 NOTE: 1. Without the pump type water level switch output cables short circuit. 6 6 7 7 OFF 1 ON 2 2 2 Floor&Ceiling Unit Standard static pressure duct unit Low static pressure duct unit Indoor models Indoor models Select bits SW2 NO.1,2 OFF 1 ON 2 OFF 5 OFF 5 ON ON ON OFF 4 ON OFF 4 High speed FAN SPEED Super speed LED Digital tube 8MIN Heating fan stop time 4MIN 24℃ 15℃ Anti-cold wind off the fan temperature selection bit 2℃ 6℃ Heating temperature compensation No power-down memory power-down memory SW2 NO.4 Receive and display light board OFF 3 OFF 3 ON ON SW2 NO.3 FAN SPEED CHOICE Ceiling cassette unit OFF 1 ON ON OFF 1 SW2 NO.5 OFF ON ON SW2 NO.6 OFF OFF ON ON SW2 NO.7 OFF ON 8 8 SW2 NO.8 OFF ON OFF GD Chigo Heating & Ventilation Equipment Co., Ltd. 39 N CN10 L CN3 CN4 CN2 HEATER R410A50Hz Universal Outdoor Series Technical Manual 5. Wiring Diagrams 5.1 CTA-18HVR1 ALARM S CN37 CN27 Wi re control L1 N1 S COMMUNICATION CN1 RY6 CN23 Duct display RY4 L N POWER Line pressing buttons That DIP to ON Line pressing buttons T1 T2 CN17 1 OUT POWER CN11 PUMP ON That DIP to Digital NOTE: 1 1 2 3 4 5 6 7 8 SW2 FACTORY DEFAULT ON OFF PUMP BR BK OFF ON OFF C10 CN1 ALARM CN37 S SW1 4 4 4 105 105 105 7 9 8 IC4 3 70 6 E21 3 70 5 IC2 T1 T2 T2B CN17 RY6 5 CN27 Wire control 2 53 PTC 1 2 3 4 5 6 7 8 OFF 2 53 3 COM NO J N CN10 L CN3 CN26 CN4 CN2 HEATER REM O_CT RL OUT POWER CN11 PT1 CN18 Water-SW LEFT FAN CN7 IC2 2 53 2 PUMP RD COM SW2 PT3 2 53 1 YE/GN Connect to the outdoor L1N1 S NO F01 PT2 BR BK BK ON Controller BR L N POWER INPUT CN26 REMO_CTRL WATER SWITCH 5 DC FAN YE/GN PTC 10 C10 IC4 RY4 CN23 Duct display RIGHT FAN CN8 E21 T1 Receive and display light board 2 53 0 The power (PH) of indoor units can be set throughDIP switch SW1(16- bit disc DIP ) on the indoor control panel before delivery, the detailed information is as follows: HP POWER SW1 4 NOTE: 1. Without the pump type water level switch output cables short circuit. 6 6 7 7 Floor&Ceiling Unit Standard static pressure duct unit Ceiling cassette unit Low static pressure duct unit Indoor models Indoor models Select bits SW2 NO.1,2 ON OFF 1 2 ON OFF 1 2 ON OFF 1 2 ON SW2 NO.3 OFF 5 OFF 5 ON ON ON OFF 4 ON OFF 4 High speed FAN SPEED Super speed Digital tube LED 8MIN 4MIN Heating fan stop time 24℃ 15℃ Anti-cold wind off the fan temperature selection bit 2℃ 6℃ Heating temperature compensation No power-down memory power-down memory SW2 NO.4 Receive and display light board OFF 3 OFF 3 ON ON FAN SPEED CHOICE OFF 1 2 SW2 NO.5 OFF ON ON SW2 NO.6 OFF OFF ON ON SW2 NO.7 OFF 8 8 SW2 NO.8 ON OFF ON OFF GD Chigo Heating & Ventilation Equipment Co., Ltd. 40 N CN10 L CN3 CN4 CN2 HEATER R410A50Hz Universal Outdoor Series Technical Manual 5.2 CTA-24HVR1 R410A50Hz Universal Outdoor Series Technical Manual 5.3 CTB-36HVR1 PUMP BK BR BK COM HP POWER SW1 NOTE: 2 53 0 2 53 1 2 53 2 2 53 3 2 53 4 SW2 3 70 5 PTC RY6 5 CN27 Wire control T1 T2 T2B CN17 3 70 6 DC FAN 5 IC2 LEFT FAN CN7 Water-SW CN18 WATER SWITCH C10 IC4 RY4 RIGHT FAN 5 E21 RIGHT FAN CN8 CN23 Duct display 10 4 4 4 105 105 105 7 9 8 T1 Receive and display light board Note:Model 105 kw ground does not need to connect outdoor YE/GN Controller 1 2 3 4 5 6 7 8 OFF SW1 PT3 Connect to the outdoor L1N1 S RD ON CN26 REMO_CTRL NO CN37 S OUT POWER CN11 N CN10 L CN3 CN4 CN2 HEATER PUMP CN1 BK BR ALARM BR L N POWER INPUT PT1 The power (PH) of indoor units can be set throughDIP switch SW1(16- bit disc DIP ) on the indoor control panel before delivery, the detailed information is as follows: YE/GN PT2 1. The factory default CN18 need cables short circuit 2、The water pump outlet are connected by a field installation COM NO J CN26 REM O_CT RL CN37 S OUT POWER CN11 CN4 HEATER N CN10 L CN3 CN2 PUMP CN1 ALARM L N POWER SW2 T1 T2 T 2B CN17 PTC RY6 CN27 Wi re control L1 N1 S IC2 COMMUNICATION Line pressing buttons That DIP to ON Line pressing buttons 1 1 That DIP to Digital NOTE: ON OFF ON OFF 1 2 3 4 5 6 7 8 SW2 FACTORY DEFAULT ON OFF E21 CN23 Duct display C10 IC4 RY4 T1 Low static pressure duct unit Indoor models Indoor models Select bits SW2 NO.1,2 ON Ceiling cassette unit 1 2 1 2 ON OFF OFF ON Floor&Ceiling unit Standard static pressure duct unit SW2 NO.3 OFF 5 OFF 5 ON ON ON OFF 4 ON OFF 4 FAN SPEED High speed Super speed LED Digital tube 2℃ 6℃ Heating temperature compensation No power-down memory power-down memory SW2 NO.4 Receive and display light board OFF 3 OFF 3 ON ON FAN SPEED CHOICE 1 2 1 2 ON OFF OFF SW2 NO.5 SW2 NO.6 ON OFF 6 ON OFF 6 ON 8MIN 4MIN Heating fan stop time 24℃ 15℃ Anti-cold wind off the fan SW2 NO.7 temperature selection bit OFF 7 ON OFF 7 ON 8 8 SW2 NO.8 OFF ON OFF GD Chigo Heating & Ventilation Equipment Co., Ltd. 41 F01 R410A50Hz Universal Outdoor Series Technical Manual 6. Capacity Tables Cooling 6.1 CTA-18HVR1 MODEL COOLING Indoor Conditions 21ºC DB Total capacity kW 15ºC WB Input kW. 24ºC DB Total capacity kW 17ºC WB Input kW. 27ºC DB Total capacity kW 19ºC WB Input kW. 32ºC DB Total capacity kW 23ºC WB Input kW. 21ºC 5.27 1.07 5.78 1.14 6.24 1.18 7.17 1.41 CTA-18HVR1 OUTDOOR TEMPERATURE DRY 25ºC 30ºC 35ºC 40ºC 4.98 4.68 4.55 4.33 1.24 1.41 1.55 1.74 5.47 5.33 4.99 4.79 1.31 1.47 1.67 1.85 5.94 5.72 5.38 5.18 1.41 1.58 1.72 1.96 6.81 6.58 6.26 5.98 1.61 1.8 2.04 2.26 21ºC 6.95 5.44 7.59 1.63 8.27 1.68 9.43 1.97 CTA-24HVR1 OUTDOOR TEMPERATURE DRY 25ºC 30ºC 35ºC 40ºC 6.63 6.39 6.03 5.82 5.18 4.96 4.7 4.51 7.23 6.99 6.58 6.33 1.84 2.1 2.3 2.55 7.88 7.61 7.18 6.93 1.94 2.17 2.45 2.66 9.04 8.71 8.25 7.90 2.27 2.56 2.81 3.1 45ºC 5.61 4.52 6.12 2.79 6.68 2.97 7.5 3.53 21ºC 10.21 2.27 11.16 2.4 12.16 2.59 13.8 2.91 CTB-36HVR1 OUTDOOR TEMPERATURE DRY 25ºC 30ºC 35ºC 40ºC 9.77 9.41 9.6 8.56 2.67 2.97 3.3 3.61 10.69 10.31 9.77 9.37 2.76 3.1 3.46 3.86 11.62 11.18 10.59 10.18 2.94 3.31 3.76 4.05 13.36 12.87 12.18 11.68 3.32 3.8 4.2 4.65 45ºC 8.31 3.98 9.05 4.19 9.88 4.4 11.3 5.08 45ºC 4.24 1.9 4.66 2.0 5.04 2.09 5.82 2.48 6.2 CTA-24HVR1 MODEL COOLING Indoor Conditions 21ºC DB Total capacity kW 15ºC WB Input kW. 24ºC DB Total capacity kW 17ºC WB Input kW. 27ºC DB Total capacity kW 19ºC WB Input kW. 32ºC DB Total capacity kW 23ºC WB Input kW. 6.3 CTB-36HVR1 MODEL COOLING Indoor Conditions 21ºC DB Total capacity kW 15ºC WB Input kW. 24ºC DB Total capacity kW 17ºC WB Input kW. 27ºC DB Total capacity kW 19ºC WB Input kW. 32ºC DB Total capacity kW 23ºC WB Input kW. 42 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Heating 6.4 CTA-18HVR1 MODEL HEATING Indoor Conditions Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. 15ºC 18ºC 20ºC 22ºC 27ºC CTA-18HVR1 OUTDOOR CONDITIONS 24ºC DB 18ºC WB 10.26 3.09 9.64 2.9 9.0 2.67 8.23 2.39 7.24 2.07 12ºC DB 11ºC WB 8.23 2.41 7.74 2.3 7.15 2.1 6.56 1.91 5.73 1.6 7ºC DB 6ºC WB 4ºC DB 3ºC WB 0ºC DB -1ºC WB -5ºC DB -6ºC WB -7ºC DB -8ºC WB 6.81 2.01 6.42 1.83 5.88 1.66 5.51 1.58 4.76 1.36 6.17 1.88 5.86 1.8 5.37 1.59 4.87 1.5 4.3 1.27 5.77 1.8 5.52 1.67 5.13 1.57 4.67 1.46 4.11 1.2 5.17 1.71 4.86 1.6 4.53 1.48 4.17 1.35 3.6 1.1 4.88 1.6 4.6 1.51 4.23 1.35 3.85 1.27 3.4 1.07 6.5 CTA-24HVR1 MODEL HEATING Indoor Conditions Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. 15ºC 18ºC 20ºC 22ºC 27ºC CTA-24HVR1 OUTDOOR CONDITIONS 24ºC DB 18ºC WB 13.86 4.24 13.03 3.97 12.12 3.67 11.13 3.35 9.63 2.91 12ºC DB 11ºC WB 11.13 3.34 10.44 3.1 9.61 2.94 8.88 2.64 7.72 2.28 7ºC DB 6ºC WB 4ºC DB 3ºC WB 0ºC DB -1ºC WB -5ºC DB -6ºC WB -7ºC DB -8ºC WB 9.29 2.8 8.71 2.58 8.12 2.41 7.5 2.18 6.48 1.9 8.37 2.66 7.83 2.47 7.27 2.27 6.7 2.06 5.82 1.83 7.88 2.5 7.42 2.34 6.83 2.17 6.33 1.94 5.51 1.67 6.94 2.37 6.54 2.21 6.14 2.05 5.55 1.8 4.83 1.59 6.53 2.23 6.12 2.05 5.71 2.01 5.2 1.75 4.51 1.51 6.6 CTB-36HVR1 MODEL HEATING Indoor Conditions 15ºC 18ºC 20ºC 22ºC 27ºC 43 Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. 24ºC DB 18ºC WB 19.28 6.24 17.98 5.91 16.76 5.3 15.34 5.0 13.39 4.27 12ºC DB 11ºC WB 15.46 5.05 14.42 4.7 13.4 4.17 12.32 4.01 10.73 3.43 CTB-36HVR1 OUTDOOR CONDITIONS 7ºC DB 4ºC DB 0ºC DB 6ºC WB 3ºC WB -1ºC WB 12.88 11.6 10.94 4.15 3.92 3.68 12.0 10.9 10.3 3.87 3.69 3.49 11.66 10.0 9.6 3.33 3.21 3.09 10.35 9.23 8.8 3.3 3.09 2.96 8.93 8.12 7.67 2.87 2.76 2.56 -5ºC DB -6ºC WB 9.67 3.53 9.15 3.29 8.43 2.97 7.73 2.8 6.7 2.4 -7ºC DB -8ºC WB 9.04 3.32 8.49 3.07 7.85 2.85 7.23 2.61 6.33 2.28 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 7. Static Pressure External static pressure (Pa) 7.1 CTA-18HVR1 CTA-18HVR1 Pa 50 40 Super high speed 30 High speed Mid speed 20 Low speed 10 200 300 400 500 600 700 Air volume(m 3 /h) 800 900 1000 1100 1200 7.2 CTA-24HVR1 CTA-24HVR1 External static pressure (Pa) Pa 60 50 Super high speed 40 High speed 30 Mid speed Low speed 20 10 700 44 800 900 1000 1100 1200 1300 1400 Air volume(m 3 /h) 1500 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 7.3 CTB-36HVR1 Pa CTB-36HVR1 External static pressure (Pa) 60 50 40 Super high speed High speed 30 Mid speed 20 Low speed 10 1100 1200 1400 1600 1800 2000 2200 Air volume(m 3 /h) 45 2400 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 8 Electric Characteristics Model Indoor Units Indoor Fan Motor Hz Voltage Min. Max. kW CTA-18HVR1 50 220-240V 198V 254V 0.068 CTA-24HVR1 50 220-240V 198V 254V 0.068 CTB-36HVR1 50 220-240V 198V 254V 0.225 46 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 9 Accessories Name Soundproof/insulation sheath Tubing & Fittings Drainpipe Fittings others 47 Shape Quantity 2 Binding tape 1 Seal sponge 1 Seal ring 1 Remote controller (optional) 1 Operation & installation instruction manual 1 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 10 The Specification of Wiring Model 18kBtu/h 24kBtu/h Indoor power supply V/Ph/Hz 220~240/1/50 Outdoor power supply V/Ph/Hz 220~240/1/50 mm 2 3×2.5 3×2.5 Power supply individually for indoor and outdoor 3×1.5/3×4.0 mm 2 4×2.5 4×2.5 3×1.0 Outdoor Power Supply Connection wiring Power wiring Signal wiring 48 36kBtu/h From indoor unit From indoor unit GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 11 Field Wiring 49 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 12. Exploded View 12.1 CTA-18HVR1, CTA-24HVR1 50 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual No. Part Name No. Part Name 1 Cover attached cotton assay 9 Evaporator 1.1 Cover plate assay 9.1 Evaporator assy 1.1.1 Cover 9.1.1 Up evaporator 1.1.2 Hook 9.1.2 Down evaporator 1.2 cover cotton 9.1.3 Collecting pipe assy 1.3 Cotton on outlet 9.1.4 Shunt assy 1.4 Cotton on the cover 9.2 Damped rubber 2 panel upper air inlet channel 9.3 Damped rubber 3 panel bellow air inlet channel 9.4 sheath insullation 4 Motor assy 9.5 sheath insullation 4.1 Cotton on fan fixing board assy 10 Left clapboard attached cotton assy 4.2 Holder for fan motor 10.1 Left clapboard 4.3 Wind turbine volute 10.2 Left clapboard cotton 4.4 Biaxial indoor DC 10.3 Left and right outlet cotton 4.5 Motor support joint 11 Left inlet clapboard attached cotton assy 4.6 Right fixing clamp for motor 11.1 Left clapboard of air inlet channel 4.7 Left fixing clamp for motor 11.2 The right plate of air inlet channel 4.8 Axis 12 Cotton posted a pipe cover assy 12.1 Output pipe of left clapboard 4.9 Bearing holder 4.10 The holder of axis assy 12.2 Cotton posted a pipe cover 5 The right plate of air inlet channel 13 Pump holder attached cotton assy 6 panel bellow attached cotton assy 13.1 Pump holder 6.1 Down Panel assy 13.2 Pump cover sponge 6.1.1 Down Panel 14 Up foam 6.1.2 fan fixed plate 15 E-parts assy 6.2 Down outlet cotton 15.1 Base for electric control 6.3 Dowm panel cotton 15.2 Electric control cover 7 Right clapboard cotton assy 15.3 Plastic base for PCB 7.1 Right clapboard 15.4 Electronic control board for indoor unit 7.2 Right clapboard cotton 15.5 Terminal 8 Bubble water pan 15.6 Relay 51 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 12.2 CTB-36HVR1 52 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 13.Trouble shooting 13.1 Fault code table 53 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Floor & Ceiling 1.Features ........................................................................................... 55 3. Specifications ................................................................................... 57 3.Dimensions ....................................................................................... 59 4.Service Space .................................................................................. 60 5.Wiring Diagrams ............................................................................... 61 6.Capacity Table .................................................................................. 62 7.Electric Characteristics ..................................................................... 64 8. Exploded View ................................................................................. 65 9.Accessories ...................................................................................... 67 10.The Specification of Power ............................................................. 68 11.Field Wiring ..................................................................................... 69 12.Troubleshooting .............................................................................. 70 54 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 1 Features 1. Flexible installation, ceiling suspended and floor standing. 2. Adopting centrifugal fans, higher ESP and longer air flow distance. 3. Two way auto-swing function, built-in two louver motor, vertical and horizontal air-flow adjustment. 4. Washable air filter 55 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 5. LED display optional. 6. High efficiency DC fan motor, low noise and more comfortable. 7. New upper and lower buckle type wheel case, the upper plastic wheel case can be removed Alone, which is convenient adjust the wheel motor. 8. Water pump optional, pumping head is up to 1200mm. 9. Adopting waterproof plastic film on water collector, avoiding water leakage. 10. Self-diagnostic function and multi protection; Auto-restart function. 11. Standard for wireless controller; option for wired controller Standard 56 Optional GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 2 Specifications Model KW CUA-18HVR1 220~240V/1Ph/ 50Hz 2.0-5.3-5.6 CUA-24HVR1 220~240V/1Ph/5 0Hz 3.5-7.0-8.0 CUA-36HVR1 220~240V/1Ph/50 Hz 6.6-10.5-12.8 Power input W 420-1840 600-3000 1050-4660 Current input A 1.8-7.8 2.5-13 4.2-24.8 SEER W/W 5.5 5.5 5.1 Capacity KW 3.0-5.3-6.0 4.5-7.0-8.5 7.35-10.5-13.2 Input W 640-1640 1500-2600 1100-4150 Rated current A 3.0-8.0 5.5-11 4.4-18.5 W/W 3.8 3.8 3.8 Energy rate Cooling A A A Energy rate Heating A A A Max. power input W 2000 3200 4800 Max. current input A 10 14 26 Model DR-310-120LD -8 DR-310-120LD-8 DR-310-120LD-8 Brand Panasonic Panasonic Panasonic W 120 120 120 r/min 1400 1400 1400 Insulation class E E E Number of rows Tube pitch(a)xrow pitch(b) Fin spacing 2 2 3 mm 21×13.37 21×13.37 21×13.37 mm 1.4 1.4 1.4 Hydrophilic Hydrophilic Hydrophilic Ф7 inner grooved 1000x252x26.7 4 2 Ф7 Ф7 inner grooved inner grooved 1000x252x26.74 1000x252x26.74 2 4 Indoor power supply Capacity Cooling Heating SCOP Indoor fan motor Power output Speed Indoor coil V/Ph/Hz Fin type Tube outside dia. and type Coil length x height x width Number of circuits mm mm Indoor air flow(High speed) 3 m /h 900 1150 1800 Indoor noise level dB(A) 46~58 56~63 53~63 Dimension(W*H*D) Body(mm) 1245×680×244 1245×680×244 1245×680×244 Packing(W*H*D) Body(mm) 1325×770×330 1325×770×330 1325×770×330 Net/Gross weight Body(Kg) 34/40 34/40 35/41 MPa 3.8 3.8 3.8 R410A R410A R410A mm Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 mm DN25 DN25 DN25 Indoor unit Max pressure Refrigerant type Refrigerant Liquid side/Gas side piping Drainage pipe Standard controller 57 Standard for remote controller(wired controller for option) GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Operation temp Ambient temp °C 16~32 16~32 16~32 cooling °C -5~50 -5~50 -5~50 heating °C -15~30 -15~30 -15~30 20-35 28-50 40-70 75/165/189 75/165/189 75/165/189 2 Application area m Stuffing Quantity(20'/40'/40'HQ) set Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. Piping: 7.5m(horizontal) 2.Nominal heating capacities are based on the following conditions: Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 7.5m(horizontal) 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. 58 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 3 Dimensions 3.1 CUA-18HVR1 CUA-24HVR1 CUA-36HVR1 150 200 680 1245 1119 59 235 247 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 4 Service Space 60 GD Chigo Heating & Ventilation Equipment Co., Ltd. Indoor models Select bits Indoor models Low static pressure duct unit Ceiling cassette unit Standard static pressure duct unit S CN37 4 4 4 105 105 105 7 9 8 Floor&Ceiling Unit 3 70 6 F0 1 SW2 1 2 3 4 5 6 7 8 OFF 5 That DIP to ON ON 1 2 1 2 1 2 1 2 2 53 4 3 70 5 SW2 NO.1,2 OFF ON ON OFF ON OFF OFF 2 53 3 Controller SW1 OUT POWER CN11 CN2 PUMP CN1 ALARM L CN10 N CN26 CN4 REMO_CTRL HEATER ON NOTE: ON 1 That DIP to Digital SW2 2 53 2 1 2 3 4 5 6 7 8 2 53 1 WATER SWITCH CN27 Wire control CN17 T2B T2 T1 Water-SW CN18 RY6 PTC RD BK PUMP SW2 NO.3 Super speed High speed FAN SPEED FAN SPEED CHOICE ON OFF 3 ON OFF 3 OFF 4 OFF 4 ON ON Digital tube LED Receive and display light board SW2 NO.4 POWER INPUT Connect to the outdoor OFF 1 ON OFF 2 53 0 SWING2 CN19 IC2 YE/GN ON OFF HP POWER SW1 10 Receive and display light board 5 LEFT FAN CN7 SWING1 CN20 RIGHT FAN CN8 RY4 CN23 Duct display T1 E21 COM SW2 NO.5 OFF ON 6 6 ON ON OFF 5 ON OFF 5 SW2 NO.6 OFF OFF ON 7 7 ON SW2 NO.7 OFF ON 8 8 SW2 NO.8 OFF ON OFF power-down memory No power-down memory Heating temperature compensation 6℃ 2℃ Anti-cold wind off the fan temperature selection bit 15℃ 24℃ 4MIN Heating fan stop time 8MIN Note:Model 105 kw ground does not need to connect outdoor GD Chigo Heating & Ventilation Equipment Co., Ltd. 61 RD BK RD BK NO RD L1N1 S L N YE/GN IC4 C10 DC FAN1 CN3 R410A50Hz Universal Outdoor Series Technical Manual 5 Wiring Diagrams 5.1 CUA-18HVR1 CUA-24HVR1 CUA-36HVR1 PT3 PT2 PT1 R410A50Hz Universal Outdoor Series Technical Manual 6. Capacity Table Cooling 6.1 CUA-18HVR1 MODEL COOLING Indoor Conditions 21ºC D Total capacity Kw 15ºC W Input kW. 24ºC D Total capacity kW 17ºC W Input kW. 27ºC D Total capacity kW 19ºC W Input kW. 32ºC D Total capacity kW 23ºC W Input kW. 21ºC 5.21 1.1 5.7 1.13 6.2 1.22 7.13 1.4 CUA-18HVR1 OUTDOOR TEMPERATURE DRY 25ºC 30ºC 35ºC 40ºC 4.98 4.79 4.52 4.36 1.25 1.41 1.56 1.71 5.47 5.26 4.95 4.78 1.31 1.49 1.62 1.83 5.95 5.71 5.3 5.16 1.4 1.59 1.66 1.96 6.84 6.57 6.22 5.94 1.60 1.83 2.03 2.22 45ºC 4.21 1.91 4.61 2.02 5.01 2.12 5.77 2.43 21ºC 6.85 1.52 7.52 1.63 8.15 1.73 9.37 2.02 CUA-24HVR1 OUTDOOR TEMPERATURE DRY 25ºC 30ºC 35ºC 40ºC 6.55 6.31 5.94 5.71 1.79 2.03 2.28 2.53 7.18 6.91 6.52 6.26 1.88 2.15 2.32 2.65 7.79 7.51 7.10 6.81 2.01 2.22 2.4 2.8 8.96 8.63 8.16 7.82 2.3 2.61 2.87 3.22 45ºC 5.54 2.78 6.05 2.87 6.58 3.07 7.57 3.51 21ºC 10.12 2.2 11.1 2.32 12.06 2.41 13.86 2.87 CUA-36HVR1 OUTDOOR TEMPERATURE DRY 25ºC 30ºC 35ºC 40ºC 9.68 9.33 8.81 8.45 2.52 2.88 3.25 3.53 10.61 10.23 9.64 9.26 2.7 3.02 3.4 3.8 11.54 11.12 10.50 10.1 2.89 3.23 3.61 4.0 13.26 12.78 12.06 11.58 3.28 3.78 4.21 4.58 45ºC 8.18 3.89 8.96 4.13 9.75 4.31 11.21 5.0 6.2 CUA-24HVR1 MODEL COOLING Indoor Conditions 21ºC DB Total capacity kW 15ºC WB Input kW. 24ºC DB Total capacity kW 17ºC WB Input kW. 27ºC DB Total capacity kW 19ºC WB Input kW. 32ºC DB Total capacity kW 23ºC WB Input kW. 6.3 CUA-36HVR1 MODEL COOLING Indoor Conditions 21ºC DB Total capacity kW 15ºC WB Input kW. 24ºC DB Total capacity kW 17ºC WB Input kW. 27ºC DB Total capacity kW 19ºC WB Input kW. 32ºC DB Total capacity kW 23ºC WB Input kW. 62 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Heating 6.4 CUA-18HVR1 MODEL HEATING Indoor Conditions Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. 15ºC 18ºC 20ºC 22ºC 27ºC 24ºC D 18ºC W 10.28 3.02 9.67 2.81 8.87 2.6 8.21 2.36 7.15 2.0 12ºC D 11ºC W 8.21 2.4 7.72 2.19 7.12 2.01 6.56 1.88 5.72 1.63 CUA-18HVR1 OUTDOOR CONDITIONS 7ºC D 4ºC D 0ºC D 6ºC W 3ºC W -1ºC W 6.88 6.2 5.85 2.0 1.86 1.76 6.45 5.81 5.49 1.85 1.73 1.64 5.8 5.38 5.08 1.57 1.59 1.52 5.51 4.96 4.66 1.5 1.42 1.37 4.78 4.3 4.06 1.33 1.26 1.18 -5ºC D -6ºC W 5.16 1.65 4.85 1.54 4.49 1.41 4.13 1.3 3.58 1.11 -7ºC D -8ºC W 4.81 1.54 4.52 1.44 4.18 1.32 3.85 1.21 3.37 1.0 12ºC D 11ºC W 10.91 3.62 10.27 3.3 9.48 3.12 8.76 2.81 7.57 2.32 CUA-24HVR1 OUTDOOR CONDITIONS 7ºC D 4ºC D 0ºC D 6ºC W 3ºC W -1ºC W 9.12 8.24 7.78 3.0 2.82 2.66 8.56 7.68 7.31 2.69 2.62 2.48 7.8 7.16 6.78 2.2 2.19 2.13 7.31 6.58 6.24 2.13 2.1 2.07 6.34 5.72 5.42 2.02 1.98 1.85 -5ºC D -6ºC W 6.86 2.55 6.42 2.32 5.92 2.08 5.5 1.96 4.68 1.7 -7ºC D -8ºC W 6.42 2.41 6.01 2.24 5.58 2.02 5.12 1.85 4.46 1.53 12ºC D 11ºC W 15.74 4.66 14.78 4.37 13.7 4.04 12.62 3.7 11.03 3.19 CUA-36HVR1 OUTDOOR CONDITIONS 7ºC D 4ºC D 0ºC D 6ºC W 3ºC W -1ºC W 13.12 11.82 11.15 3.89 3.68 3.45 12.32 11.12 10.49 3.61 3.47 3.26 11.55 10.25 9.7 3.25 3.1 3.0 10.51 9.45 8.94 3.04 2.88 2.78 9.13 8.22 7.74 2.65 2.5 2.35 -5ºC D -6ºC W 9.81 3.39 9.21 3.19 8.54 2.96 7.88 2.71 6.86 2.35 -7ºC D -8ºC W 9.19 3.07 8.63 2.85 8.02 2.66 7.35 2.41 6.39 2.09 6.5 CUA-24HVR1 MODEL HEATING Indoor Conditions Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. 15ºC 18ºC 20ºC 22ºC 27ºC 24ºC D 18ºC W 13.68 4.65 12.85 4.34 11.89 3.95 10.95 3.64 9.51 3.14 6.6 CUA-36HVR1 MODEL HEATING Indoor Conditions Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. 15ºC 18ºC 20ºC 22ºC 27ºC 63 24ºC D 18ºC W 19.64 5.88 18.49 5.51 17.12 5.1 15.75 4.68 13.66 4.02 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 7 Electric Characteristics Model CUA-18HVR1 CUA-24HVR1 CUA-36HVR1 64 Hz 50 50 50 Indoor Units Voltage Min. 220-240V 198 220-240V 198 220-240V 198 Max. 254 254 254 Indoor Fan Motor kW 0.12 0.12 0.12 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 8. Exploded View 8.1 CUA-18HVR1 CUA-24HVR1 CUA-36HVR1 65 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual No. Part Name Quantity No. Part Name Quantity 1 Rear cover with cotton 1 17 Supporting board for motor 1 2 Chassis assembly 1 18 Weld assembly for intermediate transverse girder 1 3 Electric box cover 1 19 Right mounting plate of evaporator 1 4 E-part box mat 1 20 Right cover 1 5 Indoor PCB assembly 1 21 Right sealplate 1 5.1 E-part box 1 22 Right separating board 1 5.2 Indoor PCB 1 23 Evaporator component 1 5.3 Relay 1 23.1 Left mounting plate of evaporator 1 5.4 plastic base of Electric control board 1 23.2 Shunt capillary assembly 1 5.5 Terminal 1 23.3 Air inlet header pipe assembly of evaporator 1 6 Left sealplate 1 23.4 Evaporator assembly 1 7 Left cover 1 24 Air-out frame component 1 8 Left hoisting pate 1 24.1 Fixing board assembly for air-out frame 1 9 Lelf separating board Ⅰ 1 24.2 Display film 1 10 Motor holder 1 24.3 Display lamp panel 1 11 Wheel volute 3 24.4 Vertical step motor 1 12 Indoor fan motor 1 24.5 Horizontal step motor 1 13 Connecting shaft 1 24.6 Endbearing of louver 2 14 Air inlet grille 2 24.7 Intermediate bearing of louver 8 15 Top Cover assembly 1 24.8 Guard vane 10 16 Weld assembly of Water drain pan 1 25 Upper horizontal louver 1 16.1 Water outlet rubber cover 1 26 Down horizontal louver 1 66 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 9 Accessories Name Shape Quantity Installation fittings 1.Hanging arm 2 2. Remote controller 1 3. Remote controller holder (optional) 1 5. Mounting screw (ST2.9×10-C-H) 2 6. Alkaline dry batteries (AM4) 2 7. Installation & operation instruction manual 1 Controller Others 67 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 10 The Specification of Power Model 18kBtu/h 24kBtu/h Indoor power supply V/Ph/Hz 220~240/1/50 Outdoor power supply V/Ph/Hz 220~240/1/50 Power wiring mm 2 3×2.5 3×2.5 Power supply individually for indoor and outdoor 3×1.5/3×4.0 Signal wiring mm 2 4×2.5 4×2.5 3×1.0 Outdoor Power Supply Connection wiring 68 36kBtu/h From indoor unit From indoor unit GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 11 Field Wiring 69 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 12 Troubleshooting Fault code Table 70 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Part 3 Outdoor Units 1.Specification ..................................................................................... 72 2.Dimensions ....................................................................................... 74 3.Service Space .................................................................................. 76 4.Wiring Diagrams ............................................................................... 77 5.Electric Characteristics ..................................................................... 79 6.Operation Limits ............................................................................... 80 7.Sound Levels .................................................................................... 81 8.Exploded View .................................................................................. 82 9.Troubleshooting ................................................................................ 89 71 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Outdoor Unit 1 Specification Model COU-18HDR1 COU-24HDR1 COU-36HDR1 V/Ph/Hz 220~240/1/50 220~240/1/50 220~240/1/50 KW 2.0-5.3-5.6 4.5-7.0-8.0 7.35-10.5-12.8 Power input W 330-1750 540-2940 950-4560 Current input A 1.2-7.2 2.2-12.7 3.5-24 KW 3.0-5.3-6.0 4.5-7.0-8.5 7.35-10.5-13.2 Power input W 550-1550 1440-2540 1000-4050 Current input A 5.2-10.7 TNB220FFEM C DC/ROTARY 3.7-17.8 MNB36FAAMC Type 2.4-7.0 DA131S1B-28F Z DC/ROTARY Brand GMCC Mitsubishi Mitsubishi Outdoor power supply Capacity Cooling Capacity Heating Model Compressor Outdoor fan motor Frequency range Hz 12-120 20-220 30-360 Capacity W 3925 6940 11900 Input W 1005 2150 3580 Current(RLA) A 7.1 8.7 13.6 Refrigerant oil ml 450 520 1400 Model DR-310-50-8 DR-310-72-8 DR-380-100-8 Brand Panasonic Panasonic Panasonic W 50 72 100 r/min 800 800 800 Insulation class E E E Number of rows Tube pitch(a)xrow pitch(b) Fin spacing 2 2 2 mm 22×19.05 25×21.65 22×19.05 mm 1.6 1.8 1.6 Hydrophilic Hydrophilic Hydrophilic 7.94 9.52 7.94 inner grooved inner grooved 623×660×38.1 626×800×43.3 4 4 inner grooved 610×1280× 38.1 10 Power output Speed Outdoor coil DC/ROTARY Fin type Tube outside dia. and type Coil length x height x width Number of circuits mm mm Outdoor air flow(High speed) m /h 3 4000 5000 7000 Outdoor noise level dB(A) 63 67 68 Dimension(W*H*D) mm 930×370×700 911×400×1335 Packing(W*H*D) mm 990×410×770 Net/Gross weight kg 45/49 960×390×835 1025×430×88 0 59/69 g R410A/1800 R410A/2400 R410A/4400 EXV EXV EXV 4.4/1.1 4.4/1.1 4.4/1.1 Outdoor unit Refrigerant type/quantity Throttle part Design pressure 72 MPa 964×402×1445 96/101 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Max pressure Connection wire Refrigerant piping Ambient temp Stuffing Quantity 73 MPa 3.8 3.8 3.8 mm 2 3×2.5 3×2.5 3×1.5/3×4.0 Signal wiring mm 2 4×2.5 4×2.5 3×1.0 Liquid side/Gas side mm φ6.35/φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Max. pipe length m 15 20 20 Max. high drop m 8 10 10 cooling °C -5~50 -5~50 -5~50 heating °C 20'/40'/40'H Q -15~30 -15~30 -15~30 100/200/208 70/140/144 32/64/64 Power wiring GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 2 Dimensions 1.1 COU-18HDR1 2.2 COU-24HDR1 74 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 1335 2.3 COU-36HDR1 400 360 400 585 911 75 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 3 Service Space >30cm Air inlet >30cm Obstacle >50cm (Wall or obstacle) Fix with bolt Air inlet Maintain channel >150cm >60cm Air outlet Deep foundation Necessary width 300mm is necessary between 2 outdoor units 300mm M10 bolt 4pieces per unit 76 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 4 Wiring Diagrams 4.1 COU-18HDR1 COU-24HDR1 (Power supply from indoor unit) ELECTRICAL WIRING DIAGRAM Current Mutual BK inductor BK RD PFC Ctrl S N INDOOR COMM 1 2 SW4 ON SW5 J2 CHECK SW1 SW2 COOL 1 2 LP HP P-OUT Trans In Relay1 CN26 HEAT1 4-WAY Relay1 YE/GN 4-WAY N SW3 1 2 T5 ON BR DOWN-DC FAN YE/GN SW3 SW4 YE/GN N-OUT Reactor SW5 BK N' DC FAN Factory default RD 1 2 1 2 1 2 E Filter P' BL N P BK BK RD Caution 1: The Current Mutual inductor must be through with power cord. 77 GD Chigo Heating & Ventilation Equipment Co., Ltd. Power supply Connect to Indoor INV Comp. UP-DC FAN 5 BL WV U T4 T3 2 BR T1 6 DC+ E3 CN6 BL I-CHECK CPU DC- IC6 BK RD L-IN 2 Exhaust Ambient temp. Condensing temp. temp. RD YE P+ NN- 6 CAP E2 P+ N- BR P+ BL CAP E1 -N P+ W V U ON BL CAP T1 L-OUT 2 6 YE YE IPM COMM 4 DISPLAY RY1 -15V +15V Trans Out P-IN DC-2 AC-1 BL P-BL 2 N-IN Hi.Prss Lo.Prss swicth. swicth. N-OUT P-L RD YE/GN C P-OUT Bridge 2 B BR BL DC-1 C11 N-IN BR A Relay AC-2 VGND BL N YE R410A50Hz Universal Outdoor Series Technical Manual 4.2 COU-36HDR1 (Power supply independently) BK 78 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 5 Electric Characteristics Outdoor Unit Model 79 Hz 254 Min. Max. Outdoor motor (kw) COU-18HDR1 50 254 198 254 0.050 COU-24HDR1 50 254 198 254 0.072 COU-36HDR1 50 418V 198 254 0.100 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 6 Operation Limits Operation mode Outdoor temperature(℃) Room temperature(℃) Cooling operation -5~50 16~32 Heating operation -15~30 16~32 80 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 7. Sound Levels 18kBtu/h-24kBtu/h 36kBtu/h Outdoor Unit Microphone H 1.0m Note: H= 0.5 × height of outdoor unit 81 Note: The point A is in the middle of the whole outdoor panel. Model Noise level dB(A) COU-18HDR1 63 COU-24HDR1 67 COU-36HDR1 68 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 8. Exploded View 8.1 COU-18HDR1 82 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Part Name Quantity No. Part Name Quantit y Cover plate assay 1 10 Maintenance board 1 1.1 cover 1 11 Chassis assy 1 1.2 Specifications sponge 1 12 4-Ways valve assy 1 Electronic control components 1 13 Compressor 1 2.1 E-box welded components 1 14 Throttle part 1 2.2 Cover for E-parts 1 14. 1 Electric expansive valve (EEV) 1 2.3 Capacitor plates 1 14. 2 Control wire for EEV 1 2.4 Current transformer 1 15 Plastic front nets 1 2.5 Electric control 1 16 Front clapboard 1 3 Amorphous PFC inductor 1 17 Left clapboard 1 4 Middle separating board 1 18 Small handle 1 5 Right side board 1 19 Condenser assy 1 6 Large handle 1 20 Holder for fan motor assy 1 7 cut-off valve C 1 21 Uniaxial fan DC motor 1 8 cut-off valve C 1 22 Propeller fan 1 9 Valve holder 1 No 1 2 83 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 8.2 COU-24HDR1 84 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual No. Part Name Quantity Part Name Quantity Cover attached cotton assay 1 14 Inverter compressor 1 1.1 Cover 1 15 Separating board 1 1.2 Specifications sponge 1 16 Discharge pipe assy 1 2 Back frame 1 16.1 Discharge pipe 1 3 Left clapboard 1 16.2 Probe of copper pipe 1 4 Condenser welding assy 1 17 4-Ways valve assy 1 4.1 Condenser 1 17.1 4-Ways valve 1 4.2 Collector welding components 1 17.2 4-Ways valve connecting pipe 1 4.3 Distributing capillary assy 1 17.3 4-Ways valve connecting pipe 1 4.4 EEV welding assy 1 17.4 Length of straight pipe 1 5 Front top net 1 18 Big handle 1 6 Front panel 1 19 connecting pipe of 4-Ways valve 1 7 Holder for fan motor 1 20 Suction pipe 1 8 Propeller fan 1 21 E-parts assy 1 9 Holder for fan motor welding assy 1 21.1 Heatsink 1 10 Maintenance panel 1 21.2 fixing board for heatsink 1 11 Chassis 1 21.3 E-parts welding assy 1 12 Vapour-liquid separator 1 21.4 E-parts module board 1 13 Valve holder assy 1 21.5 Main control board 1 13.1 Valve holder 1 22 Right clapboard 1 13.2 Cut-off valve 1 23 Handle 2 13.3 Cut-off valve 1 1 85 No. GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 8.3 COU-36HDR1 86 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual No. Part Name Quantity Part Name Quantity Condenser 1 16.3 Oil return pipe filter 1 1.1 Condenser assy 1 16.4 Transition pipe 1 1.2 Flute shunt components 1 16.5 Connection pipe of Oil separator 1 1.3 Confluence components 1 16.6 Transition pipe 1 1.4 Cold out pipe 1 16.7 Oil return pipe capillary 1 1.5 Damping rubber 1 16.8 discharge pipe B 1 2 Top net 2 17 Valve holder 1 3 Right clapboard 1 18 Rail 1 4 Handle 3 19 Contactor 1 5 High pressure cut-off valve assy 1 20 After backplane 1 5.1 High pressure cut-off valve pipe 1 21 4-Ways valve assy 1 5.2 Cut-off valve DN8 1 21.1 4-Ways valve 1 6 Front panel 1 21.2 Filter 1 7 Separating board welding assy 2 21.3 High-pressure switch 1 7.1 Separating board 1 21.4 cut-off valve DN13 1 7.2 Winding card 1 21.5 Length of straight pipe 2 8 Chassis assy 1 21.6 4-Ways valve connecting pipe A 1 8.1 Foot 2 21.7 4-Ways valve connecting pipe C 1 8.2 Chassis 1 21.8 4-Ways valve connecting pipe D 1 8.3 Unit foot bolt 3 21.9 4-Ways valve connecting pipe E 1 9 Inverter compressor 1 22 Column 1 10 EXV assy 1 23 Cover attached cotton assay 1 10.1 Transition pipe 1 23.1 Cover board 1 10.2 Length of straight pipe 1 23.2 Specifications cotton 1 10.3 Capillary 1 23.3 Specifications sponge 1 10.4 filter 1 24 E-parts assy 1 10.5 EXV 1 24.1 E-parts welding assy 1 10.6 Oil return pipe filter 1 24.2 Flap welding assy 1 Suction pipe assy 1 24.3 Heatsink cover 1 11.1 Suction pipe A 1 24.4 Capacitor clamp 1 11.2 Suction pipe B 1 24.5 E-parts heat sink 1 11.3 Low-pressure swicth 1 24.6 Main control board 1 12 discharge pipe assy 1 24.7 PFC board 1 12.1 discharge pipe 1 24.8 IPM module board 1 12.2 Probe of copper pipe 1 25 Holder for fan motor connect board 1 1 11 87 No. GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 13 Vapour-liquid separator 1 26 Holder for fan motor assy 1 14 Rear side of the valve panel 1 26.1 Propeller fan 2 15 The right side of the valve panel 1 26.2 Holder for fan motor welding assy 1 16 Oil separator assy 1 26.3 fixing board for fan welding assy 1 16.1 Oil separator 1 26.4 Fan motor 2 16.2 Connection pipe 1 88 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 9 Troubleshooting 9.1 Fault display 89 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 9.2 Parameter table for spot inspection of outdoor unit 90 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Part 4 Installation 1.Precaution on Installation ..................................................................92 2.Vacuum Dry and Leakage Checking .................................................93 3.Additional Refrigerant Charge ...........................................................95 4.Water Drainage .................................................................................96 5.Insulation Work ..................................................................................99 6.Test Operation .................................................................................101 91 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 1. Precaution on Installation 1.1. Measure the necessary length of the connecting pipe, and make it by the following way. a. Connect the indoor unit at first, then the outdoor unit. Bend the tubing in proper way. Do not harm them. CAUTIONS:  Daub the surfaces of the flare pipe and the joint nuts with frozen oil, and wrench it for 3~4 rounds  With hands before fasten the flare nuts. Be sure to use two wrenches simultaneously when you connect or disconnect the pipes. Pipe gauge Tightening torque Φ6.4 15~16N.m (153~163 kgf.cm) 25~26N.m (255~265kgf.cm) 35~36N.m (357~367kgf.cm) 45~47N.m (459~480 kgf.cm) 65~67N.m (663~684kgf.cm) Φ9.5 Φ12.7 Φ15.9 Φ19.1 b. c. Flare dimension A Min (mm) Max 8.3 8.7 12.0 12.4 15.4 15.8 18.6 19.1 22.9 23.3 Flare shape The stop value of the outdoor unit should be closed absolutely (as original state). Every time you connect it, first loosen the nuts at the part of stop value, then connect the flare pipe immediately (in 5 minutes). If the nuts have been loosened for a long time, dusts and other impurities may enter the pipe system and may cause malfunction later. So please expel the air out of the pipe with refrigerant before connection. Expel the air after connecting the refrigerant pipe with the indoor unit and the outdoor unit. Then fasten the nuts at the repair-points. 1.2. Locate The Pipe a. Drill a hole in the wall (suitable just for the size of the wall conduit), then set on the fittings such as the wall conduit and its cover. b. Bind the connecting pipe and the cables together tightly with binding tapes. Do not let air in, which will cause water leakage by condensation. c. Pass the bound connecting pipe through the wall conduit from outside. Be careful of the pipe allocation to do no damage to the tubing. 1.3. Connect the pipes. 1.4. Then, open the stem of stop values of the outdoor unit to make the refrigerant pipe connecting the indoor unit with the outdoor unit in fluent flow. 1.5. Be sure of no leakage by checking it with leak detector or soap water. 1.6. Cover the joint of the connecting pipe to the indoor unit with the soundproof / insulating sheath (fittings), and bind it well with the tapes to prevent leakage. 92 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 2 Vacuum Dry and Leakage Checking 2.1 Vacuum Dry: use vacuum pump to change the moisture (liquid) into steam (gas) in the pipe and discharge it out of the pipe to make the pipe dry. Under one atmospheric pressure, the boiling point of water(steam temperature) is 100℃. Use vacuum pump to make the pressure in the pipe near vacuum state, the boiling point of water falls relatively. When it falls under outdoor temperature, the moisture in the pipe will be vaporized. 2.2 Vacuum dry procedure There are two methods of vacuum dry due to different construction environment: common vacuum dry, special vacuum dry. ①. Common vacuum dry procedure  Vacuum dry (for the first time)---connect the all-purpose detector to the inlet of liquid pipe and gas pipe, and run the vacuum pump more than two hours (the vacuum pump should be below -755mmHg)  If the pump can’t achieve below -755mmHg after pumping 2 hours, moisture or leakage point will still exist in the pipe. At this time, it should be pumped 1 hour more.  If the pump can’t achieve -755mmHg after pumping 3 hours, please check if there are some leakage points.  Vacuum placement test: place 1 hour when it achieves -755mmHg, pass if the vacuum watch shows no rising. If it rises, it shows there’s moisture or leakage point.  Vacuuming from liquid pipe and gas pipe at the same time.  Sketch map of common vacuum dry procedure. 93 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual ②. Special vacuum dry procedure  This vacuum dry method is used in the following conditions:  There’s moisture when flushing the refrigerant pipe.  Rainwater may enter into the pipe.  Vacuum dry for the first time ······2h pumping ③. Vacuum destroy for the second time ······Fill nitrogen to 0.5Kgf/cm 2 Because nitrogen is for drying gas, it has vacuum drying effect during vacuum destroy. But if the moisture is too much, this method can’t dry thoroughly. So, please pay more attention to prevent water entering and forming condensation water. ④. Vacuum dry for the second time······1h pumping Determinant: Pass if achieving below -755mmHg. If -755mmHg can’t be achieved in 2h, repeat procedure ③ and ④. ⑤. Vacuum placing test ······1h ⑥. Sketch map of special vacuum dry procedure 94 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 3 Additional Refrigerant Charge Caution ● Refrigerant cannot be charged until field wiring has been completed. ● Refrigerant may only be charged after performing the leak test and the vacuum pumping. ● When charging a system, care shall be taken that its maximum permissible charge is never exceeded, in view of the danger of liquid hammer. ● Charging with an unsuitable substance may cause explosions and accidents, so always ensure that the appropriate refrigerant is charged. ● Refrigerant containers shall be opened slowly. ● Always use protective gloves and protect your eyes when charging refrigerant. The outdoor unit is factory charged with refrigerant. Calculate the added refrigerant according to the diameter and the length of the liquid side pipe of the outdoor unit/indoor unit R(g) D(mm) L(m) Less than 5m (One-way) Added Refrigerant When Over 5m(One-way) φ6.4 Φ9.5 Φ12.7 — — — 30g/m×(L-5) 65g/m×(L-5) 120g/m×(L-5) Remark: R (g): Additional refrigerant to be charged L (m): The length of the refrigerant pipe (one-way) D (mm): Liquid side piping 95 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 4 Water Drainage 4.1 Gradient and Supporting 4.1.1 Keep the drainpipe sloping downwards at a gradient of at least 1/100. Keep the drainpipe as short as possible and eliminate the air bubble. 4.1.2 The horizontal drainpipe should be short. When the pipe is too long, a prop stand must be installed to keep the gradient of 1/100 and prevent bending. Refer to the following table for the specification of the prop stand. Hard PVC pipe Diameter Distance between the prop stands 25~40mm 1~1.5m 4.1.3. Precautions ① The diameter of drainpipe should meet the drainage requirement at least. ② The drainpipe should be heat-insulated to prevent atomization. ③ Drainpipe should be installed before installing indoor unit. After powering on, there is some water in water-receiver plate. Please check if the drain pump can operate correctly. ④ All connection should be firm. ⑤ Wipe color on PVC pipe to note connection. ⑥ Climbing, horizontal and bending conditions are prohibited. ⑦ The dimension of drainpipe can’t less than the connecting dimension of indoor drainpipe. ⑧ Heat-insulation should be done well to prevent condensation. ⑨ Indoor units with different drainage type can’t share one convergent drainpipe. 4.2 Drainpipe Trap 4.2.1. If the pressure at the connection of the drainpipe is negative, it needs to design drainpipe trap. 4.2.2. Every indoor unit needs one drainpipe trap. 4.2.3. A plug should be designed to do cleaning. 96 50cm 50cm P l u g GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 4.3 Upwards drainage (drain pump) For Four-way cassette(compact) For Four-way cassette 4.4 Convergent drainage 4.4.1. The number of indoor units should be as small as possible to prevent the traverse main pipe overlong. 4.4.2. Indoor unit with drain pump and indoor unit without drain pump should be in different drainage system. 4.4.3. Selecting the diameter Number of connecting indoor units → Calculate drainage volume → Select the diameter Calculate allowed volume =Total cooling capacity of indoor units(HP)×2 (l/ hr) Allowed volume(lean 1/50) (l/ hr) I.D. (mm) Thick Hard PVC ∽≤14 ¢25 3.0 集中排水管 Hard PVC 14<∽≤88 ¢30 3.5 Hard PVC 88<∽≤334 ¢40 4.0 Hard PVC 175<∽≤334 ¢50 4.5 Hard PVC 334<∽ ¢80 6.0 97 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 4.5 Drainage test 4.5.1Drainage without drain pump After finishing drainpipe installation, pour some water into the water receiver plate to check if the water flows smoothly. 4.5.2 Drainage with drain pump ① Poke the Water Level Switch, remove the cover, use water pipe to pour 2000ml water into the water receipt plate through the water inlet. ② Turn on the power to Cooling operation. Check the pump’s operation and switch on the Water Level Switch. Check the pump’s sound and look into the transparent hard pipe in the outlet at the same time to check if the water can discharge normally. ③ Stop the air conditioner running, turn off the power, and put back the cover.  Stop the air conditioner. After 3 minutes, check if it has abnormity. If the collocation of drainpipes is illogical, the water will flow back overfull, which will cause the alarm lamp flashes, even overflow from the water receipt plate.  Keep on pouring water until it gives an alarm signal for high water level, check if the pump drains water at once. If the water level can’t fall below the alarmed water level after 3 minutes, the air conditioner will stop. Turn off the power and drain the remained water, and then turn on the air conditioner. Note: the drain stuff in the main water receipt plate is for maintenance. Stuff up the drain stuff to prevent water leakage. 98 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 5 Insulation Work 5.1 Insulation material and thickness 5.1.1. Insulation material Insulation material should adopt the material which is able to endure the pipe’s temperature: no less than 70℃ in the high-pressure side, no less than 120℃ in the low-pressure side(For the cooling type machine, no requirements at the low-pressure side.)  Example: Heat pump type----Heat-resistant Polyethylene foam (withstand above 120℃) Cooling only type----Polyethylene foam (withstand above 100℃) 5.1.2. Thickness choice for insulation material Insulation material thickness is as follows: Refrigerant pipe Drainage pipe Pipe diameter (mm) Φ6.4—Φ25.4 Φ28.6—Φ38.1 Inner diameterΦ20—Φ32 Adiabatic material thickness 10mm 15mm 6mm 5.2 Refrigerant pipe insulation 5.2.1. Work Procedure ① Before laying the pipes, the non-jointing parts and non-connection parts should be heat insulated. ② When the gas proof test is eligible, the jointing area, expanding area and the flange area should be heat insulated 5.2.2. Insulation for non-jointing parts and non-connection parts wrong Gas pipe and liquid pipe should not be put together to insulate 99 right Insulate the gas pipe (cooling only) Insulate the gas pipe and liquid pipe GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual For construction convenience, before laying pipes, use insulation material to insulate the pipes to be deal with, at the same time, at two ends of the pipe, remain some length not to be insulated, in order to be welded and check the leakage after laying the pipes. 5.2.3. Insulate for the jointing area, expanding area and the flange area ① Insulate for the jointing area, expanding area and the flange area should be done after checking leakage of the pipes ② Make sure there’s no clearance in the joining part of the accessorial insulation material and local preparative insulation material. 5.3 Drainage pipe insulation The connection part should be insulated, or else water will be condensing at the non-insulation part. 5.4 Note 5.4.1 The jointing area, expanding area and the flange area should be heat insulated after passing the pressure test 5.4.2 The gas and liquid pipe should be heat insulated individually, the connecting part should be heat insulated individually. 5.4.3 Use the attached heat-insulation material to insulate the pipe connections (pipes’ tie-in ,expand nut ) of the indoor unit 100 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 6. Test Operation (1) The test operation must be carried out after the entire installation has been completed. (2) Please confirm the following points before the test operation.  The indoor unit and outdoor unit are installed properly.  Tubing and wiring are correctly completed.  The refrigerant pipe system is leakage-checked.  The drainage is unimpeded.  The ground wiring is connected correctly.  The length of the tubing and the added stow capacity of the refrigerant have been recorded.  The power voltage fits the rated voltage of the air conditioner.  There is no obstacle at the outlet and inlet of the outdoor and indoor units.  The gas-side and liquid-side stop values are both opened.  The air conditioner is pre-heated by turning on the power. (3) According to the user's requirement, install the remote controller when the remote controller's signal can reach the indoor unit smoothly. (4) Test operation Set the air conditioner under the mode of "COOLING" with the remote controller, and check the following points. Indoor unit  Whether the switch on the remote controller works well.  Whether the buttons on the remote controller works well.  Whether the air flow louver moves normally.  Whether the room temperature is adjusted well.  Whether the indicator lights normally.  Whether the temporary buttons works well.  Whether the drainage is normal.  Whether there is vibration or abnormal noise during operation. Outdoor unit  Whether there is vibration or abnormal noise during operation.  Whether the generated wind, noise, or condensed of by the air conditioner have influenced your neighborhood.  Whether any of the refrigerant is leaked. 101 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual Control Part 5 Controller 1.Wireless Remote Controller ............................................................ 103 2.Wire Controller ................................................................................ 106 150 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 1 Wireless Remote Controller 1.1 Jingling TB-YKQ-D02b USE OF REMOTE CONTROLLER The controller below is the Jingling Common Remote Controller, SWING key, TURBO key, LAMP key and CLEAN key is applicable for special latest developed new models instead of normal ones. FUNCTION KEY A. ON/OFF key: Press the key and the remote control will switch circularly in the order: ON→OFF→ON. When it is powered on at first from off state to on state, the default setting of work condition is ( The set temperature is 25℃ and the mode , wind speed, swing and air door are all automatic and there is no lamp, no turbo, no purification, no sleep, no timing and no hold function ). When it is not powered on firstly from off state to on state, the work condition is as the same as the state before stopping. It will cancel damp, purification, sleep, turbo and timing 103 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual running mode. B. MODE key: Press the key to switch modes in the order: automatic cooling →dehumidify →heating →ventilating →automatic. C. "▼" key: In dehumidifying mode and automatic mode, pressing the key cannot change the temperature. In other mode, press the key once and the temperature will decrease 1℃ in the order: 32℃→31℃→…→17℃→16℃ . D. "▲"key: In dehumidifying mode and automatic mode, pressing the key cannot change the temperature. In other mode, press the key once and the temperature will increase 1℃ in the order: 16℃→17℃→…→31℃→32℃. E. SWING key: In dehumidifying mode, the swing mode is in the stable wind mode without change. In other mode, press the key to switch modes in the order: swing → stable wind→ natural wind →swing F. AIR FLOW key: The default air flow is in the swing mode when starting firstly and press the key to switch modes in the order: swing →stop →swing. G. WIND SPEED key: The default wind speed is in the automatic wind mode when starting firstly. The remote control won’t react by pressing the key because the wind speed can’t be adjusted and in low speed in dehumidifying mode. In other mode, press the key to switch modes in the order: Automatic wind→ high speed →middle speed→ low speed →automatic wind H. TIMER key: The default mode is in no timing state, press the key to set timing time with hour as its union. The switch order is: 1H→2H→…→24H→cancel→1H…. Press the key to set timing starting in the off state and set timing stopping in the on state. After setting timing function, the time keeps decreasing per hour until the time decreasing to the timing on or timing off and the timing display will be cancelled at the same time. Pressing MODE key can’t cancel timing in timing mode which will send out the order of timing time by pressing other key. I. TURBO key: The default state for the control is no turbo and the key don’t work in the automatic mode, dehumidifying mode and ventilating mode (It will not display any contents and not send out any codes). The control, however, will 104 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual switch between on and off by pressing the key in other mode. The wind speed isn’t indicated in turbo mode and it will be cancelled for changing modes and setting sleep mode. J. SLEEP key: Press the key to switch modes in the order: sleep→ cancel sleep→ sleep. The sleep function won’t be cancelled for changing modes. Press the key to set sleep mode and the wind speed will automatically be switched to low speed and it can adjust the wind speed by pressing the WIND SPEED key (except dehumidifying mode). K. LOCK key: The default state is in no LOCK key state, press the key to select modes in order: LOCK key →cancel LOCK key→ LOCK key; In LOCK key mode, all keys except LOCK key of the remote control can’t work . (NOTE: In LOCK key mode, the remote and operation panel of the unit both will be locked automatically by pressing the key and press the key again, they will be unlocked. As for the split unit, it only holds the control rather than urgent keys and the panel will make a reaction.) L. LAMP key: The default state is in no LAMP key state, press the key to select modes in order: LAMP key →cancel LAMP key→ LAMP key; In LAMP key mode, pressing MODE key can’t cancel the show of LAMP key. M. CLEAN key: The default state is in no purification state, press the key to select modes in order: CLEAN →cancel CLEAN→ CLEAN; In purification mode, pressing CLEAN key can’t cancel purification function. Press the key when the remote control is closed, the control will switch modes in the order: CLEAN →cancel CLEAN→ CLEAN; when you stop the unit and turn on the purification switch, except the wind, the stable swing and air door swing speed aren’t adjusted. 105 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 2 Wire Controller ZKX-CMVE-05 106 GD Chigo Heating & Ventilation Equipment Co., Ltd. R410A50Hz Universal Outdoor Series Technical Manual 107 GD Chigo Heating & Ventilation Equipment Co., Ltd.