Transcript
Technical Product Guide
A range of simple digital thermostats and programmable thermostats with large LCD displays for zone control of underfloor (UFH) or wall hung radiator (WHR) heating circuits
CS-11 LCD Simple NSB Digital Thermostat • • • • • • •
Large LCD, simple, clear, backlit display. (65mm x 48mm) Large easy to use buttons Extra slim control panel (15mm deep) Night Set Back function (NSB) Temperature range limiting function Frost protection and heat on indicator Controls air, floor or air & floor temperatures using remote sensor
Zone Controls | CS-11
CS11 Thermostats
CS-11 LCD 7-day Programmable Digital Thermostat • • • • • •
Large LCD, simple, clear, backlit display. (65mm x 48mm) Day and time display Extra slim control panel (15mm deep) Controls air, floor and air & floor temperatures using remote sensor Heating ‘on’ and programme number icons Offers simple to use 24 hour, 7-day, 6+1 day or 5+2 day programming options with six time / temperature events per day • Manual override and vacation mode • Frost protection, pump protection and optimum start functions
TST-11 Touchscreen Programmable Thermostat • Large LCD, simple, clear, backlit display. (95mm x 55mm) • Simple-to-use touchscreen interface with large, easy-to-read character size and extralarge touch keys for easy operation • Offers simple to use 24 hour, 7-day, 6+1 day or 5+2 day programming options with six time / temperature events per day. • Comfort, economy and vacation modes • Frost protection function
CS-11 LCD Timeswitch • • • • • • • •
Large LCD, simple, clear, backlit display. (65mm x 48mm) Large easy to use buttons Extra slim control panel (15mm deep) Offers simple to use 24 hour, 7-day, 6+1 day or 5+2 day programming options with three on off periods per day. Manual override and vacation mode Heat on indicator Volt-free contacts mean that it can be used for both 230V and 24V applications Battery back-up in the event of power failure.
For more information please call us on 01993 824900 or view our website at www.emmeti.co.uk
1
Technical Product Guide
Zone Controls | CS-11
CS-11 Range
EWC-1/EWC-2
Introduction to CS-11 Thermostats A range of wall mounted thermostats - one digital night set back (NSB) thermostat and two programmable thermostats including a touchscreen version. We also have a digital time switch available with the same styling. The LCD display features large, clear graphics which makes using and programming the thermostats extremely simple. Despite their simple and unobtrusive appearance, they are packed full of features. All models have an optional remote sensor which can be used either to sense air temperature remotely for use in bathrooms for example or to sense floor temperature where additional protection is required for the floor finish. The thermostat can be set to sense air temperature only, floor temperature only or air and floor temperature. Depending on the model selected, Emmeti CS-11 programmable thermostats have a choice of 24 hour, 5+2 day, 6+1 day or 7 day programming with up to six time / temperature events to give a flexible choice to meet different needs for different lifestyles.
2
Our CS-11 LCD Simple NSB Digital thermostat offers a night setback function (NSB) enabling the thermostat to lower the room temperature at night between 2oC to 7oC (via a timeswitch) which reduces heating costs. Available also is a temperature range limiting function, allowing to limit the minimum set temperature 10oC - 20oC or to limit the maximum set temperature 20oC - 35oC. The CS-11 LCD (Digital) timeswitch enables the time control or setback temperature control of underfloor of radiator heating circuits using Emmeti EWC-1 and EWC-2 wiring centres. It offers a choice of 24 hour, 5+2 day or 7 day programming with up to three on-off periods per day. The volt-free contacts mean that it can be used for both 230V and 24V applications and it has a battery back-up in the event of power failure. The Emmeti range of CS-11- thermostats are suitable for homes and commercial applications with a ‘button lock’ feature to prevent accidental tampering with settings. All models are fully approved and tested, and carry the CE mark.
For more information please call us on 01993 824900 or view our website at www.emmeti.co.uk
Technical Product Guide CS-11 Range
Model: Description
Dimension H x W x D (mm):
U9310090
U9310044
U9310010
U9310070
CS-11 LCD Digital Setback Thermostat
CS-11 LCD 7-day Programmable Digital Thermostat
TST-11 Touchscreen Programmable Thermostat
CS-11 LCD Digital Timeswitch
86 x 86 x 13
86 x 86 x 13
96 x 127 x 19
86 x 86 x 13
28
28
28
28
230V ~
230V ~
230V ~
230V ~
Overall depth incl. back box (mm) Operating voltage: Temperature control options
Zone Controls | CS-11
Technical Data
Air, floor or air & floor
Air, floor or air & floor
Air, floor or air & floor
N/A
Air temperature control range:
5oC – 35oC
5oC – 35oC
5oC – 35oC
N/A
Floor temperature control range:
20oC – 40oC
20oC – 40oC
20oC – 40oC
N/A
- at resistive loads:
16A
16A
16A
16A
- at inductive loads, cos φ = 0.6:
5A
5A
5A
5A
SPST
SPST
SPST
SPST
Display:
LCD 48mm high x 65mm wide, blue backlight
LCD 48mm high x 65mm wide, blue backlight
LCD 59mm high x 95mm wide, blue backlight
LCD 48mm high x 65mm wide, blue backlight
Setback:
Yes Temperature reduction between 2oC 7oC degrees
N/A
N/A
N/A
Switching capacity
Switching output:
5 oC
Frost protection setting:
5o C 0 C - 45 C
0 C - 45oC
0oC - 45oC
Set point switching differential:
1oC - 5oC
1oC - 10oC
1oC - 10oC
N/A
NTC10kΩ Length - 3m
NTC10kΩ Length - 3m
NTC10kΩ Length - 3m
N/A
N/A
24 hour, 5+2 day, 6+1 day or 7day options 6 time / temperature events per day / group of days
24 hour, 5+2 day or 7 day options 6 time / temperature events per day/ group of days
Three on-off periods per day 24hr, 5 +2 and 7 day
Double insulatedII (
Double insulated II (
Class of protection: Ingress protection: Compliance with EMC and LV directives:
Double insulated II (
o
)
IP30
o
N/A
0 C - 45 C
Programming:
o
5o C
Ambient temperature:
Remote sensor included with thermostat:
o
IP30
o
)
IP30
)
Double insulated II (
)
IP30
Electromagnetic Compatibility Directive (89/336/EEC; 92/32/EEC) EN60730-1:2000, EN 60730-2-9:2002 Low Voltage Directive (73/23/EEC; 93/68/EEC) EN60730-1:2000, EN60730-2-9:2002
CS-11 Range CS-11 LCD Simple NSB Digital Thermostat Size Pcs./Pack Code 230V AC Button operated LCD display, white case 1 U9310090 This electronic digital thermostat is a new addition to our range of CS-11 thermostat, it offers a night setback function (NSB) enabling the thermostat to lower the room temperature at night (via a timeswitch) between 2oC to 7oC lower than the set point. Temperature range limiting function available, allowing to limit the minimum set temperature 10oC - 20OC or to limit the maximum set temperature 20oC - 35oC. Large, simple, clear, backlit, LCD display. Temperature differential 1oC. Also has built-in frost protection set at 5 oC Flame icon in display provides calling for heat indicator. The remote sensor included enables thermostat to be used for floor sensing or for remote sensing in bathroom applications. The thermostat can be set to sense air temperature only, floor temperature only or air and floor temperature together. Terminal rating 5A (inductive loads). Designed to fit into a single gang 35mm deep backbox. For installation requirements and wiring connections, please see our website www.emmeti.co.uk.
For more information please call us on 01993 824900 or view our website at www.emmeti.co.uk
3
Technical Product Guide CS-11 Range Zone Controls | CS-11
CS-11 LCD 7 day programmable digital thermostat Size Pcs./Pack 230V AC button operated, LCD display, white case 1
Code U9310044
Electronic digital programmable thermostat with pre-connected on-off contacts for 230V AC operation. Large simple clear, backlit, LCD display. Offers simple to use 24 hour, 7 day, 6+1 day or 5+2 day programming options with six time / temperature settings per day. Temperature range limiting function is available on this thermostat. Temperature differential 1oC. Flame icon in display provides calling for heat indicator. Optional sensor enables thermostat to be used for floor sensing or for remote sensing in bathroom applications. The thermostat can be set to sense air temperature only, floor temperature only or air and floor temperature together. Also has built-in frost protection set at 5oC, holiday programming, manual override features, pump exercise (15 seconds in 24 hours) and optimum start (self regulating) features included. Designed to fit into a single gang 35mm deep backbox. Terminal rating 5A (inductive loads). For installation requirements and wiring connections, please see our website www.emmeti.co.uk.
TST-11 Touchscreen Programmable Thermostat Size Pcs./Pack Code 230V AC touchscreen LCD display, white case 1 U9310010
Touchscreen Controlled
Electronic digital touchscreen programmable thermostat with pre-connected on-off contacts for 230V AC operation. Large simple clear, backlit, LCD display. Temperature differential 1oC. Flame icon in display provides calling for heat indicator. The remote sensor included enables thermostat to be used for floor sensing or for remote sensing in bathroom applications. The thermostat can be set to sense air temperature only, floor temperature only or air and floor temperature together. Programming allows six time / temperature settings per day with a choice of 24 hour, 7 day or 5+2 day programming options. Also has built-in frost protection set at 5oC, holiday programming and manual override features included. Designed to fit into a single gang 35mm deep backbox. Terminal rating 5A (inductive loads). For installation requirements and wiring connections, please see our website www.emmeti.co.uk.
CS-11 LCD Digital Timeswitch Size Pcs./Pack Code 230V AC Button operated, LCD Display, white Case 1 U9310070 Electronic digital single channel timeswitch enables the time control or setback temperature control of underfloor or radiator heating circuits using Emmeti EWC-1 and EWC-2 wiring centres. It offers a choice of 24 hour, 5+2 day or 7 day programming with up to three on-off periods per day. The volt-free contacts mean that it can be used for both 230V and 24V applications and it has a battery back-up in the event of power failure. Features include and override function and holiday function. Designed to fit into a single gang 35mm deep backbox. Terminal rating 5A (inductive loads). For installation requirements and wiring connections, please see our website www.emmeti.co.uk.
4
For more information please call us on 01993 824900 or view our website at www.emmeti.co.uk
Technical Product Guide
Installation Requirements The thermostats have been designed for fixed wiring only. Cable access is through the mounting box directly to the screwed connection terminals as shown in the Wiring section below.
Please ensure that the electrical wiring of the installation and connections to and from the thermostat are in accordance with BS 7671, the latest edition of the IET Wiring Regulations. The thermostats are designed for mounting on industry standard single-gang flush mounted wiring box with a minimum depth of 35mm. The backplate of the thermostat is secured to the mounting box after separating the front half from the backplate as shown below: the fixing centres of the backplate are also shown below.
The thermostat should be positioned approximately 1.5m from floor level and must not be positioned where it can be affected by draughts, sources of heat or cold or direct sunlight. Full installation instructions are enclosed with each product and can also be obtained from our website www.emmeti.co.uk.
Dimensions, Installation and Wiring CS-11 LCD Simple NSB Digital Thermostat: U9310090 Connections and Dimensions 65mm
13mm
WED
60mm 7mm
Rear View
49 mm
48mm
49mm
86 mm
Side View
86 m m
AUTO
86mm
Zone Controls | CS-11
CS-11 Range
4mm 50mm
28mm 86mm
Installation 1
Carefully separate the front half of the thermostat from the backplate by placing a small flat headed screwdriver into the slots on the bottom face of the thermostat.
4
2
Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat.
5
3
Place the thermostat front half somewhere safe. Make the wiring connections as shown in the diagram below.
6
Link terminals 1 to 3 for 230VAC live output
Remote sensor for floor temperature control
Switched live Timeswitch live output for operation of temperature setback mode
Screw the thermostat back plate on to the back box.
N
L
230V ~ 50Hz
Re-connect the thermostat ribbon cable and clip the two halves together.
For more information please call us on 01993 824900 or view our website at www.emmeti.co.uk
5
Technical Product Guide
Dimensions, Installation and Wiring CS-11 Electronic Thermostats: U9310044 Connections and Dimensions 65mm
13mm
WED
Side View 60mm 7mm
86 mm
Rear View
49 mm
49mm
86 m m
AUTO
86mm
48mm
Zone Controls | CS-11
CS-11 Range
4mm 50mm
28mm 86mm
Installation 3
2
1
Carefully separate the front half of the thermostat from the backplate by placing a small flat headed screwdriver into the slots on the bottom face of the thermostat.
Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat.
CS-11 LCD 7-day Programmable Digital Thermostat TST-11 Touchscreen Programmable Thermostat
5
4
Place the thermostat front half somewhere safe. Make the wiring connections as shown in the diagram below.
6
X
NEUTRAL: DO NOT USE
Remote sensor for floor temperature control
Screw the thermostat back plate on to the back box.
6
Re-connect the thermostat ribbon cable and clip the two halves together.
Switched live output
N
L
230V ~ 50Hz
Wiring diagram
For more information please call us on 01993 824900 or view our website at www.emmeti.co.uk
Technical Product Guide CS-11 Range Zone Controls | CS-11
Dimensions, Installation and Wiring TST-11 Touchscreen Programmable Thermostat: U9310010 Connections and Dimensions 127mm
96mm
18 .5mm
Side View 4 mm
55mm
Auto
49 mm
95 mm
6 mm RT 57mm
Set Schedule
80.5mm
28mm
Installation 1
Carefully separate the front half of the thermostat from the backplate by placing a small flat headed screwdriver into the slots on the bottom face of the thermostat.
4
2
3
Carefully unplug the ribbon connector which Place the thermostat front half somewhere 7-day Programmable Digital Thermostat is plugged in to the front half of the CS-11 LCD safe. Make the wiring connections as shown thermostat. in the diagram below. TST-11 Touchscreen Programmable Thermostat
5
6
X
NEUTRAL: DO NOT USE
Remote sensor for floor temperature control
Screw the thermostat back plate on to the back box.
Re-connect the thermostat ribbon cable and clip the two halves together
Switched live output
N
L
230V ~ 50Hz
Wiring diagram
For more information please call us on 01993 824900 or view our website at www.emmeti.co.uk
7
Technical Product Guide
Zone Controls | CS-11
CS-11 Range Dimensions, Installation and Wiring CS-11 LCD Timeswitch: U9310070 Connections and Dimensions
28
Installation 2
1
Carefully separate the front half of the thermostat from the backplate by placing a small flat headed screwdriver into the slots on the bottom face of the thermostat.
Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat.
5
4
3
Place the thermostat front half somewhere safe. Terminate the thermostat as shown in the diagram below.
6
Link terminals 1 to 3 for 230VAC live output
NC switched live output
Screw the thermostat back plate on to the back box.
8
NO switched live output
N
L
230V ~ 50Hz
Re-connect the thermostat ribbon cable and clip the two halves together.
For more information please call us on 01993 824900 or view our website at www.emmeti.co.uk