Preview only show first 10 pages with watermark. For full document please download

Technical Sheet Uninterruptible Power Supply Masterys

   EMBED


Share

Transcript

File name: DCB0028-33.doc Version 23/04/2004 Technical Sheet Uninterruptible Power Supply MASTERYS® MC 3/3 R00 Strong Points - Applications VFI-SS-111 (IEC62040-3) On Line double conversion technology Perfectly stable output voltage and frequency Parallel configurations of up to 6 MASTERYS MC units ensure scalability and high reliability. High input power factor > 0.99 Low current distortion (THDI<3%) Flexible backup time: different backup capacities available inside the same cabinet Advanced graphics display for total system control RS232/RS485 serial communication interface Standard LAN (Ethernet) connection and second RS232 2 free slots for ADC relay card and (GSS) generator interface Backfeed protection Expert battery system (EBS) Redundant (separate strings) and “Hot Swappable” batteries “Always On Mode” function to optimise performance, correcting harmonics generated by the load “Energy Saver” function to optimise the performance of redundant parallel mode Installable in standard 19” rack cabinets (up to 30kVA) - Protection of Mission Critical IT applications: Banking EDP centres IT networks Hospital institutions Protection of industrial applications: Medium/large enterprises Industrial transformations Automatic systems Protection of public utility/services applications: Sorting/distribution centres Universities - Railway stations/Airports MASTERYS is the most effective solution for protecting your loads not only against black outs, but from any other type of electrical noise and disturbance thanks to the VFI (Voltage and Frequency Independent) on line double conversion technology it uses. This new technology is based on multiprocessor and IGBT architechture and ensures total reliability in any operating environment and situation. Description of the UPS system The MC models offer excellent performance thanks to the IGBT based low distortion rectifier, to the standard LAN connection and to the “Always On” feature that optimises efficiency keeping the harmonics correction. When necessary or for special protection architectures, up to six units of the models in the MC range can be connected in parallel. Masterys MC can also manage the generator set thanks to the GSS interface. A new Expert Battery System optimises battery use and recharging in accordance with the type of battery and environmental conditions rationalising the use of the accumulators and therefore prolonging the average battery life. Standard features and benefits Options Complete: detailed information and numerous commands thanks to the advanced mimic panel Convenient: standard 10Mb Ethernet LAN (RJ45) connection with second RS232 interface UPS living: elegant design and ergonomic commands IT compatible: up to 30kVA installable in standard 19” rack cabinet (optional kit) Vertical backup: three UPS cabinet models satisfy a wide range of backup capacities without additional cabinets. Easy-to-move: handy wheels simplify inspection and maintenance operations. Frequency converter (from 50Hz to 60Hz and vice-versa) - Technical Specifications MASTERYS MAS-MC 320 20.000/16.000 - MAS-MC 330 MAS-MC 340 MAS-MC 360 30.000/24.000 40.000/32.000 60.000/48.000 Voltage 400 V ± 15% (up to 35% @ 70% P nominal) Nominal current 22 A 30 A 44 A 60 A 89 A Input Power factor 0.99 (THDi < 3%) Frequency 50/60 Hz ± 10% Voltage 400 V ± 1% Voltage distortion (1% on linear load) (<6% on distorting load) Output Frequency 50/60 Hz ± 2% (up 1% to 8% in operation together with generator) Overload 125% for 10 minutes 150% for 60 seconds AC/AC efficiency Up to 92% (on-line) / 96% (Eco Mode) By-pass Automatic Output nominal voltage ± 15% (up 10% to 20% in operation together with generator) Battery Battery backup time* Up to 11 a 210 min. Up to 10 a 135 min. Up to 10 a 85 min. Up to 10 a 60 min. Up to 12 a 45 min. ** Cabinet LxDxH (mm) 444x795x800/1400* 444x795x1400 Weight (kg) with batt. 195 245 312 400 170 (UPS only) Communication RS232/485 / RS232 / LAN connection Connectors Input/output Terminal block / terminal block Standards Safety/EMC IEC 62040-1-1, IEC60950-1 / (EN) IEC 62040-2 (2° edition), EN 50091-2 class A Topology IEC 62040-3 (VFI-SS-111) Temperature 0 ÷ 40° C (da 15° C a 25° C for improved battery life) Characteristics Noise < 55dB < 62dB * backup time at 75% of the maximum loads with cabinet models of different heights (S-M-T-W type) ** External battery cabinet Socomec Sicon UPS reserves the right to introduce changes referring to new technologies or regulations. Power (VA/W) MAS-MC 315 15.000/12.000 - Advanced Dry Contact (ADC) card, three dry input contacts and 4 dry output contacts (250 V). Global Supply System (GSS) generator interface, 4 dry input contacts and 1 dry output contact (60 V) Net Vision WEB/SNMP manager Uni Vision pro shutdown software LCD panel for remote communication Input/output galvanic isolation transformer External manual bypass Rack kit to install BC and MC models up to 30kVA in 19” rack cabinets Parallel configuration kit External battery cabinets to extend backup time (W type) ACS fuction, enables the synchronization with an alternative power source MAS-MC 380 80.000/64.000 119 A Up to 8 a 35 min. ** 180 (UPS only)