Preview only show first 10 pages with watermark. For full document please download

Technical Specification_mdr

   EMBED


Share

Transcript

ZODIAC DATA SYSTEMS GMBH HS500-10214+10314/HS500-20214+20314 Technical Specification HEIM DATaRec 4 MDR-8s/MDR-8sf General Power supply The HEIM DATaRec® 4 MDR-8s and MDR-8sf are digital data acquisition systems that can be equipped with user changeable signal conditioning modules to meet various applications. The system contains a CF card slot for the recording media. MDR-8s Total system bit rate MDR-8s MDR-8sf Bus data rate Data format Internal storage device Storage capacity Available module slots Input signals Modules Dimensions Weight Cooling ZODIAC Data Systems GmbH 100 Mbit/s 240 Mbit/s 800 Mbit/s IRIG 106 chapter 10-07 complaint removable CF card 16 GB / 32 GB / 64 GB available CF cards up to 128 GB supported 8 slots are available for signal conditioning modules, all modules can be used interchangeably and exchanged by the customer - PCM serial - MIL 1553B buses - ARINC 429 buses - serial data, asynchronous and synchronous - different bandwidth analog data - Ethernet network communication - voice, compressed video - others on request 126*123.1*259.7 mm (w x h x d) 5 kg conducted, no fans Power consumption MDR-8s MDR-8sf RTC Time accuracy HPO (optional) 11 - 36 V DC according to MIL-STD704E including power interruption of 50 ms 16 W (without signal modules) 21 W (without signal modules) yes ±20 ppm (power off state) ±1 ppm (power on state) 10 ppb (power on state) Built-in interfaces Input channels Voice Sampling rate High pass filter Resolution Dynamic range Input range Output range Ethernet Input format Function Max. total bit rate Page 1 of 2 All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. 2 input single ended head set channels 2 head set monitor outputs max. 25 kS/s selectable in steps 300 Hz selectable 8 bit / 16 bit 48 dB / 70 dB 1 Vrms, 1 Vpeak 0.1 Vrms, 0.1 Vpeak 10 mVrms, 10 mVpeak max. 1Vpeak 1 channel 10 / 100 / 1000 Mbit/s Ethernet bus communication Ethernet data input channel remote control, UDP broadcast, 1588 time code sync., FTP server download function 100 Mbit/s (MDR-8s) 200 Mbit/s (MDR-8sf) Document No.: 56024102 Technical Specification HEIM DATaRec 4 MDR-8s/MDR-8sf Serial Input format function Setup interface setup and control Contact remote Input level high Input level low Input impedance Status output Output current External storage interface 1 channel RS232 / RS422 GPS NMEA protocol (time sync) or asynchronous serial line input USB 2.0, Ethernet, RS232, RS422 6 discrete inputs 4.7 V- 36 V 0 V - 3.5 V min 25 kΩ 6 open collector max. 60 mA, max. 36 V (short circuit protected) eSATA Status indicators Buttons Input resolution Signal level Input impedance Output Standard codes Output accuracy Signal level Output impedance Synchronization Built-in GPS receiver Receiver type 0.1 m/s 0.5 degrees <4g < 2.5 m autonomous > 2.0 m SBAS Connectors Power Time, voice, synch Remote, media Temperature 20 character sunlight readable LED (green) 3 x LED, for system, time and media status 4 (record, stop, mode, event) Time coding Input Standard codes < 650 m/s 4 Hz 5-pin Souriau HD-D-Sub pin 26 female HD-D-Sub pin 44 female Environmental specifications Display / Buttons Recording information Max. speed Max. navigation Update rate Velocity accuracy Heading accuracy Dynamics Horizontal position Accuracy Storage temp. Humidity IRIG A, B, G, 1 pps / 10 pps and GPS time code, IEEE1588 IRIG A: 100 µs IRIG B: 1 ms IRIG G: 10 µs 0.2 Vpp – 20 Vpp (IRIG A, B, G) RS232 / RS422 (GPS, NMEA), TTL (1 pps / 10 pps) IRIG A, B, G: 100 kΩ IRIG A, B, G, J, 1 pps / 10 pps GPS replay as RS232 2 x 10-5 s (standard) 2 Vpp on 75 Ω (IRIG A, B, G) RS232 (IRIG J), TTL (1 pps / 10 pps) 75 Ω (IRIG A, B, G) 1 pps / 10 pps output with 1µs accuracy Altitude RFI Vibration Acceleration Shock operating -40°C - +71°C, with free air flow -40°C - +50°C, without free air flow (forced cooling) MIL-STD-810F Method 501 and 502 procedure II -50°C - +85°C, (long term) MIL-STD-810F method 501 and 502 procedure I 0 - 95% relative, non-condensing MIL-STD-810F method 507 0-21000 m MIL-STD-810F method 500 procedure I, II, III designed to MIL-STD-461F 10 g, MIL-STD-810F 20 g, in all directions (continuous) MIL-STD810F method 513 20 g, 11 ms MIL-STD-810E The environmental specifications for the complete system are depending on the installed storage media and signal modules. The given values apply for the complete system only if used with a industrial grade CF card. Notes The HEIM DATaRec® MDR series support record only. For replay purposes a wide range of HEIM DATaRec® 4 replay modules / systems is available. 50 channels GPS L1 frequency C/A code Galileo open service L1 frequency ZODIAC Data Systems GmbH Friedrich-Ebert-Strasse / TechnologiePark – D-51429 Bergisch Gladbach Tel.: +49 2204 84 41 00 – Fax: +49 2204 84 41 99 [email protected] – http://www.zodiac-data-systems.com ZODIAC Data Systems GmbH Page 2 of 2 All trademarks acknowledged. ICP® is a trademark of PCB. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. Document No.: 56024102