Preview only show first 10 pages with watermark. For full document please download

Teletronik Fttx Equipment Catalogue

   EMBED


Share

Transcript

INDEX OPTICAL PASSIVE EQUIPMENT OPTICAL CABLES FIG8 optical cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ADSS optical cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Underground optical cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 FTTH CABLES FTTH drop cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 ODF - PATCH PANELS 19" patch panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Wall mountable patch panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 OPTICAL SPLITTERS PLC splitters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 OPTICAL CLOSURES Outdoor optical closures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Indoor optical closures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Indoor / outdoor optical closures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 OPTICAL PATCH CORDS / PIGTAILS Patch cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 OPTICAL FILTERS 1x2 triplexer filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 1x3 triplexer filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 OPTICAL ATTENUATORS & ADAPTERS Attenuators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 ACCESSORIES Fiber connector cleaner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Mechanical splice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 OPTIAL ACTIVE EQUIPMENT OPTICAL TRAMSMITTERS & RECEIVERS OT-50xx Optical transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 EDFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 ON-500 Optical receiver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 OPTICAL MEASUREMENT Optical power meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Fiber ranger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Optical light source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Visual fault locator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Optical fiber identifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 OPTICAL CABLES 3 FIG8 OPTICAL CABLE AVAILABLE MODELS Environmental performance Number of fibers: 4 - 6 - 8 - 12 - 16 - 24 - 36 - 48 - 64 - 72 - 96 - 144 • Temperature Performance • Installation -30ºC to +70ºC • Service -30ºC to +70ºC • Storage -30ºC to +70ºC ELEMENTS MATERIAL Single Mode Optical Fibre ITU-T G652D (made by Sumitomo) NOMINAL VALUE Filling Jelly Thixotropic jelly Central Strength Member FRP Core wrap Polyester tape Filler Polyethylene Rip cord Twisted yarns (Under Sheath) Sheating High Density Polyethylene Min 1.5mm (Radial thickness) Stand wire Steel (7 strands wire) 0.9mm diameter Web Dimension High Density Polyethylene 2.0 x 2.0 ± 1.0 Suspension High Density Polyethylene Min 1.2 mm (Nominal thickness) Black / Natural WIRE STRAND WEB FILLER LOOSE TUBE WITH FIBERS & JELLY FLOODING JELLY CENTRAL STRENGTH MEMBER POLYSTER TAPE RIP CORD(S) HDPE OUTER SHEATH BLACK ADSS OPTICAL CABLE AVAILABLE MODELS Environmental performance Number of fibers: 4 - 8 - 12 - 24 - 36 - 48 - 64 - 72 - 96 - 144 • Temperature Performance • Installation -30ºC to +70ºC • Service -30ºC to +70ºC • Storage -30ºC to +70ºC Tensile strength: 1.5kN - 2.0kN - 3.0kN - 4.0 kN - 5.0kN - 6.0kN ELEMENTS MATERIAL Single Mode Optical Fibre ITU-T G652D (made by Sumitomo / Furukawa) Filling Jelly Thixotropic jelly Central Strength Member FRP Core wrap Polyester tape Filler Polyethylene Rip cord Twisted yarns (Under Sheath) Sheating High Density Polyethylene NOMINAL VALUE Black / Natural Min 1.5mm (Radial thickness) ARAMID YARNS FILLER FLOODING JELLY LOOSE TUBE WITH FIBERS & JELLY CENTRAL STRENGTH MEMBER POLYSTER TAPE RIP CORD(S) HDPE OUTER SHEATH BLACK 4 OPTICAL CABLES UNDERGROUND OPTICAL CABLE (ARMOURED) AVAILABLE MODELS Environmental performance Number of fibers: 4 - 8 - 12 - 24 - 36 - 48 - 64 - 72 - 96 - 144 • Temperature Performance • Installation -30ºC to +70ºC • Service -30ºC to +70ºC • Storage -30ºC to +70ºC Tensile strength: 1.5kN - 2.0kN - 3.0kN - 4.0 kN - 5.0kN - 6.0kN ELEMENTS MATERIAL NOMINAL VALUE Single Mode Optical Fibre ITU-T G652D (made by Sumitomo) 1310nm : 0.36 & 1550nm : 0.23 Filling Jelly Thixotropic jelly Tube PBTP Central Strength Member FRP Filler Polyethylene Water blocking elements Cable Flooding Jelly Core wrap Polyester tape Rip cord Twisted yarns (Under Sheath) Peripheral Strength Member GFR Yarns Armouring Tape Thickness ECCS Tape 0,15mm (Nominal Thickness) Outer Sheath High Density Polyethylene Min 1.5mm (Radial thickness) Black / Natural 2 ECCS TAPE FILLER LOOSE TUBE WITH FIBERS & JELLY FLOODING JELLY CENTRAL STRENGTH MEMBER GFR RIP CORD(S) HDPE OUTER SHEATH BLACK UNDERGROUND OPTICAL CABLE (NON-ARMOURED) AVAILABLE MODELS Environmental performance Number of fibers: 4 - 8 - 12 - 24 - 36 - 48 - 64 - 72 - 96 - 144 • Temperature Performance • Installation -30ºC to +70ºC • Service -30ºC to +70ºC • Storage -30ºC to +70ºC Tensile strength: 1.5kN - 2.0kN - 3.0kN - 4.0 kN - 5.0kN - 6.0kN ELEMENTS MATERIAL NOMINAL VALUE Single Mode Optical Fibre ITU-T G652D (made by Sumitomo) 1310nm : 0.36 & 1550nm : 0.23 Filling Jelly Thixotropic jelly Tube PBTP Central Strength Member FRP Filler Polyethylene FRP upcoat Polyethylene Water blocking elements Cable Flooding Jelly Core wrap Polyester tape Rip cord Twisted yarns (Under Sheath) Peripheral Strength Member GFR Yarns Outer Sheath High Density Polyethylene FILLER FLOODING JELLY Black / Natural 2 Min 1.5mm (Radial thickness) GFR YARNS LOOSE TUBE WITH FIBERS & JELLY CENTRAL STRENGTH MEMBER POLYSTER TAPE RIP CORD(S) HDPE OUTER SHEATH BLACK FTTH CABLES 5 FTTH CABLE Description Center positioned optical fiber unit Two parallel Fiber Reinforced Plastics (FRP) Black or color LSZH sheath Features • Special low-bend-sensitivity fiber provides high bandwidth and excellent communication transmission property • Two parallel FRP strength members ensure good performance of crush resistance to protect the fiber • Simple structure, light weight and high practicability • Novel flute design, easily strip and splice, simplify the installation and maintenance • Low smoke, zero halogen and flame retardant sheath • Single steel wire or massagers as the additional strength member ensures good performance of tensile strength Application • CATV Fiber Optic Sensor • Fiber to Home • Telecommunication Networks • Local Area Networks (LANs) G.652 Attenuation (+20°C) Bandwidth (ClassA) 50/125μm 62.5/125μm @850nm G.655 ≤3.5 dB/km ≤3.5 dB/km @1300nm ≤1.5 dB/km ≤1.5 dB/km @850nm ≥500 MHz·km ≥200 MHz x km @1300nm ≥1000 MHz·km ≥600 MHz x km 0.200±0.015NA 0.275±0.015NA @1310nm ≤0.45 dB/km ≤0.50 dB/km @1550nm ≤0.30 dB/km ≤0.50dB/km Numerical Aperture Cable Cut-off Wavelength λcc Fiber Count Cable Diameter mm ≤1260nm Cable Weight kg/km ≤1480nm Tensile Strength Long/Short Term N Crush Resistance Long/Short Term N/100mm Bending Radius Static/Dynamic mm 1 (2.0±0.2)×(3.0±0.2) 8 30/60 300/1000 15/30 2 (2.0±0.2)×(3.4±0.2) 8.5 30/60 300/1000 15/30 1 (2.0±0.2)×(3.8±0.2) 9 30/60 300/1000 15/30 4 (2.0±0.2)×(4.0±0.2) 10 30/60 300/1000 15/30 FRP STRENGTH MEMBER OPTICAL FIBER UNIT LSZH JACKET FRP STRENGTH MEMBER STEEL WIRE OPTICAL FIBER UNIT LSZH JACKET 6 ODF - PATCH PANELS 19" PATCH PANELS Features • Material: SPCC or AL available • Slide-out design for easy assembling • Easy and convenient 19" standard design • Cabinet surface covered with electrostatic powder coating • Bend radius of optical fiber ≥ 40mm • Variety of adaptors available Ordering options • Number of ports • connector • Multi Mode 12 – 48 SM SC, FC , LC, E2000, PC or APC SC, FC, LC, ST Features • Material: SPCC or AL available • Front and back side can have freely access to the cable • 19" standard design, easy and convenient on assembling • Cabinet surface covered with electrostatic powder coating • Bend radius of optical fiber ≥ 40mm • Variety of adaptors available Ordering options • port number • connector • Multi Mode WALL MOUNTABLE PATCH PANELS Environment Condition • Environmental temperature: -25°C ... +40°C • Relative humidity: ≤85% • Atmosphere pressure: 70~106kpa Photoelectricity Performance • Insertion Loss: ≤0.3dB; • Echo Loss: PC≥40 dB UPC≥50 dB APC≥60 dB • Insulation resistance: >1000MΩ/500VDC • Anti-voltage: 3000VDC/1min, non puncture, no arc-over Working Indexes • Standard work wavelength: 850nm 1310nm 1550nm • Fiber Movable Connector: up to GB/T 12507 standard • Fiber cable: up to GB/T 11819& GB/T 7424 standards Dimensions • Specification (H x W x depth): 435×385×55mm • Capacity: 48 cores • Can let 6 fiber cables in 12 – 144 SM SC, FC , LC, E2000, PC or APC SC, FC, LC, ST OPTICAL SPLITTERS 7 PLC SPLITTERS Features • Low Insertion Loss • Low PDL • Compact Design • Wide Operating Wavelength • Wide Operating Temperature • High Reliability and Stability • Telecordia GR-1221/1209 Compliance • Available types: filter, module, LGX, 19" ORDERING CHOICES Available Output Channel Counts from 2, 4, 8, 16, 32 to 64 Customized Module available Connectors: SM, SC, FC, LC, E2000, PC, APC PARAMETER UNIT 1x2 1x4 1x8 1x16 1x32 1x64 2x2 2x4 2x8 2x16 2x32 Insertion Loss (at 23 ºC) Max. dB 3,7 7.0 10,4 13,5 17.0 20,0 4,2 7,5 11.0 14,3 17,5 Channel Uniformity Max. dB 0,6 0,6 1.0 1,1 1,5 1,8 1,2 1,3 1,6 1,8 2,3 Polarization Dependent Loss Max. dB 0,15 0,15 0,2 0,2 0,2 0,3 0,3 0,3 0,3 0,4 0,4 Operating Wavelength nm 4x7x55 (4x7x60) 4x7x55 (4x7x60) 1260 ~ 1650 Return Loss Min. dB 55 Directivity Min. dB 55 Operating Temperature ºC Storage Temperature ºC -40 ~ 85 -40 ~ 85 Fiber Type Complied to G.652 D & G.657 A Fiber Length Customized Package Dimensions (T x W x L) Note:   mm 4x4x40 4x5x45 (4x4x40) 4x7x55 (4x7x60) 4x12x60 4x5x45 1. All measurement were done at room temperature without connectors. 2. The above spec. is under no connector. If including connector, IL, UL and PDL would increase 0.5dB, 0.2dB and 0.05dB respectively. OUTDOOR OPTICAL CLOSURES 8 OPTICAL CLOSURES KD 144 KDJ 144 KDJ 120 KDJ 408 OPTIONAL SEALING ADAPTERS KD 60 KDJ120 2-4 DOME TYPE 2+4 CABLE INLETS • Universal design (could be used for different sizes of cables; both single core and ribbon fibers; pole-mounting, aerial, and direct buried applications) • Designed for installing SC adapters & splitters • For installing various cables see optional sealing adapters Fibers/Tray Max capacity (F) Ports Suitable Dia of cable (mm) SC adapters Sealing structure Size & weight 24 120 2+4 Ø3 - Ø13.2 (depending on sealing) Max. 36 In-line mechanical sealing 480 × Ø250 / 5.8kg KDJ144 1-4 DOME TYPE 1+4 CABLE INLETS • Universal design (could be used for different sizes of cables; both single core and ribbon fibers; pole-mounting, aerial, and direct buried applications) • Adequate space for storage of fibers • For installing various cables see optional sealing adapters Fibers/Tray Max capacity (F) Ports Suitable Dia of cable (mm) SC adapters Sealing structure Size & weight 24 144 1+4 Ø3 - Ø24 (depending on sealing) Max. 36 In-line mechanical sealing 450 × Ø230 / 4.2kg KDJ408 2-4 DOME TYPE 2+4 CABLE INLETS • Universal design (could be used for different sizes of cables; both single core and ribbon fibers; pole-mounting, aerial, and direct buried applications) • Adequate space for storage of fibers • For installing various cables see optional sealing adapters Fibers/Tray Max capacity (F) Ports Suitable Dia of cable (mm) Sealing structure Size & weight 12 408 2+4 Ø8 - Ø17.5 (depending on sealing) In-line mechanical sealing 480 × Ø250 / 6.5kg KD60 6 SMALL SIZE FTTH CLOSURE • Small size with numeral cable ports and functions • 5 regular cable ports, 1 testing port, 4 pigtail outlets • Unique sealing method (could be reused many times) • Aerial, pole-mounting, direct buried, wall-mounting applications • Designed for installing SC adapters & splitters • Optional sealing adapter for 24pcs of FIG8 soft cable Fibers/Tray Max capacity (F) Ports Suitable Dia of cable (mm) Sealing structure Size & weight 12 60 5+4 Ø2 - Ø15 (depending on sealing) In-line mechanical sealing 300×220×100 / 2.7kg KD144 1-4 DOME TYPE 1+4 CABLE INLETS • Universal design (could be used for different sizes of cables; both single core and ribbon fibers; pole-mounting, aerial, and direct buried applications) • Adequate space for storage of fibers • Designed for installing splitters Fibers/Tray Max capacity (F) Ports Suitable Dia of cable (mm) SC adapters Sealing structure Size & weight 24 144 1+4 Ø8 - Ø17.5 Max. 18 Heat shrink sealing 450 × Ø230 / 4.2kg OPTIONAL SEALING ADAPTERS KDS 01 KDS 02 KDS 03 KDS 04 KDS 05 8pcs of Ø3mm soft cable 8pcs of FIG8 soft cable 6pcs of self support soft cable 4pcs of Ø5 - Ø7mm cable 16pcs of Ø5 - Ø7mm cable INDOOR OPTICAL CLOSURES 9 INDOOR OPTICAL CLOSURES FTTH WALL OUTLET KDI 12 KDI 96 KDI 4 KDI 96 INDOOR SPLICE CLOSURE • Indoor design • Prepared for adapter installation • Prepared for splitter installation • High capacity • Universal cable port for numerous drop cables Fibers/Tray Max capacity (F) Suitable Dia of cable (mm) Dimensions (W x L x H) Adapter type 24 96 Ø3 - Ø18 180 x 378 x 74mm SC, LC, FC KDI 12 INDOOR-OUTDOOR TERMINAL BOX 3 PORTS • Outdoor design protection grade IP65 • Prepared for adapter installation (SC 8 pieces) • Prepared for splitter installation • Optional universal cable ports Fibers/Tray Max capacity (F) Suitable Dia of cable (mm) Dimensions (W x L x H) Adapter type 12 12 Ø3 - Ø13 220 x 180 x 50mm SC KDI 4 INDOOR TERMINAL BOX • Small size • Low price • Prepared for adapter installation (SC 4 pieces) Fibers/Tray Max capacity (F) Suitable Dia of cable (mm) Dimensions (W x L x H) Adapter type 4 4 Ø1 - Ø5 150 x 110 x 30mm SC FTTH JUNCTION BOX • Small size • Low price • Prepared for adapter installation Fibers/Tray Max capacity (F) Suitable Dia of cable (mm) Dimensions (W x L x H) Adapter type 2 2 Ø1 - Ø5 86 x 86 x 45mm SC 10 INDOOR OPTICAL CLOSURES INDOOR / OUTDOOR OPTICAL CLOSURES KDI 24 KDI 24-S KDI 24 TERMINAL BOX • Applicable for inside and outside installation • Protective grade IP65 • It’s applicable to install up to 6 pieces of SC duplex or 6pcs of 4 fibers LC adapters • Suitable for 2x1/16 PLC installation Fibers/Tray Max capacity (F) Suitable Dia of cable (mm) Dimensions (W x L x H) Adapter type 24 24 Ø1,8 - Ø11 258×186×61mm SC, LC KDI 24-S FIBER OPTIC DISTRIBUTION BOX • Indoor / outdoor • Prepared for adapter installation • Prepared for splitter installation • High capacity • Cable parts for uncutted cables • 16 ports for drop cables Fibers/Tray Max capacity (F) Suitable Dia of cable (mm) Dimensions (W x L x H) Adapter type 24 24 Ø2 - Ø18 292 x 248 x 100mm SC, LC OPTICAL PATCH CORDS / PIGTAILS 11 PATCH CORDS Features • Variety of connectors available • Simplex or duplex • SM or MM • Various cable lenghts • Fan-out option • ITU-G6520 or G657A optional POLISHING PC APC PC Mode SM SM MM Insertion Loss (dB) ≤ 0.2 ≤ 0.2 ≤ 0.3 Return Loss dB) ≥ 45 ≥ 60 Repeatability dB) ≥ 35 ≤ 0.1 Changeability (dB) ≤ 0.2 Storage Temp ( ºC ) -40 ~ +85 Operating Temp ( ºC ) -10 ~ +75 AVAILABLE CONNECTORS (SM, 9/125) (MM, 50/125 or 62,5/125) SC/PC SC SC/APC FC FC/PC LC ORDERING CHOICES FC/APC ST Simplex/Duplex patch cord ST/PC E2000 Pigtails Various boot cable sizes LC/PC 0.9mm LC/APC E2000/APC E2000/PC FC SC LC E2000 LC duplex ST 2mm 3mm 12 OPTICAL FILTERS 1X2 TRIPLEXER FILTER Features • Wide pass band • High isolation • Low insertion loss PARAMETERS 1×2 TriPlexer Filter Central wavelength (nm) 1310, 1490, 1550 Operating Wavelength (nm) 1310±40, 1490±10 , 1550±10 Pass/Reflection wavelength (nm) On customer request Pass band insertion loss (nm) ≤0.8 (0.6 typical) Reflection band insertion loss (dB) ≤0.6 (0.4 typical) Pass band isolation (dB) ≥30 Reflection band isolation (dB) ≥15 Directivity (dB) ≥55 Return loss (dB) ≥50 PDL (dB) ≤0.1 Wavelength thermal stability (nm/ °C) ≤0.003 Insertion loss thermal stability (dB/ °C) ≤0.005 Power handling (Mw) ≤500 Operating temperature (°C) -40 ~ +85 Storage temperature (°C) -40 ~ +85 Dimensions (mm) Ф5.5× L34 Ф5.5 COMMON PORT PASS PORT REFLECTION PORT 34 55 1X3 TRIPLEXER FILTER Features • Splitting all three wavelengths • compact size • Wide pass band • High isolation • Low insertion loss PARAMETERS 1×3 TriPlexer Filter Central wavelength (nm) 1310, 1490, 1550 Operating Wavelength (nm) 1310±40, 1490±10 , 1550±10 Pass/Reflection wavelength (nm) 1490 ± 10/1310 ±40 , 1550 ± 10 Pass band insertion loss (nm) ≤0.8 (0.6 typical) Reflection band insertion loss (dB) ≤1.0 (0.8 typical) Pass band isolation (dB) ≥30 Reflection band isolation (dB) ≥15 Directivity (dB) ≥55 Return loss (dB) ≥50 PDL (dB) ≤0.1 Wavelength thermal stability (nm/ °C) ≤0.003 Insertion loss thermal stability (dB/ °C) ≤0.005 Power handling (Mw) ≤500 Operating temperature (°C) 0 ~ +75 Storage temperature (°C) -40 ~ +85 Dimensions (mm) Ф5.5×L50 1310 nm Ф5.5 1490 nm COMMON 1550 nm 50 68 OPTICAL ATTENUATORS & ADAPTERS 13 ATTENUATORS Features • High return loss • High power endurance • Wavelength independent • Low PDL • Precise control of attenuation range • Simple manipulation OPTICAL ATTENUATORS (PLUG-IN & ADAPTER TYPE) SC/PC SC/APC FC/PC FC/APC ST/PC LC/PC LC/APC E2000/APC PARAMETER UNIT DESCRIPTION Adapter type Plug-in type Operation Wavelength nm 1310, 1550 nm Attenuator Value dB 1,2,3 to 30 (base on your request) Attenuator Precision dB Max. PDL dB Return Loss dB Operating Temperature ºC -40~+75 Storage Temperature ºC -40~+75 +/-0.5 (attenuation<10) +/-1.0 (attenuation>10) 0,1 40 PC/65 APC 40 PC/65 APC ADAPTERS Features • Low insertion and back reflection loss • High precision alignment • Compact design • Zirconia ( SM ) or bronze ( MM ) sleeve PARAMETER UNIT Sleeve Operation Wavelength nm Insertion Loss dB Connection Durability Times DESCRIPTION SMPC SMAPC MM Zirconia Zirconia Phosphor Bronze 1200~1600 0,2 850 0,2 0,3 1000 Mating Operating Temperature ºC -40~+80 Storage Temperature ºC -40~+85 Relative Humidity % 95 HYBRID ADAPTERS SM-PC & APC ADAPTERS SC-FC SC/APC-FC/APC Simplex SC-LC SC/APC-FC/PC SC SC-E2000 SC/APC-LC/PC FC FC-LC SC/APC-LC/APC LC FC-E2000 SC/APC/-E2000/APC ST LC-E2000 LC/PC-SC/PC E2000 Duplex SC LC ACCESSORIES 14 FIBER CONNECTOR CLEANER Features • Safe and environment friendly • Safe to operator and no hazard to environment, no ESD contamination • Fast, effective, repeatable cleanings • Over 500 cleaning times • It is also suitable for fiber optic construction, maintenance, and equipment manufacture • It can be used for SC, FC, ST, D4, LC, DIN and Bionic connectors. • Cleaning tape is replaceable TYPE FIBER CONNECTOR CLEANER Cleaning Times Over 500 times per reel Cleaning Result -20 ... -50 dB (Return Loss) Operating Temperature -10 ... +50°C Weight 100 g MECHANICAL SPLICE ITEM TECHNICAL PARAMETERS Applicable for φ0.25 mm & φ0.90 mm Fiber Optical fiber diameter 125μm (657A & 657B) Tight buffer diameter (μm) 250μm & 900μm Fiber mode Single & multi mode Operation time About 10s (no fiber cut) Average Insert loss ≤ 0.2dB (1310nm & 1550nm) Return loss ≤ -40dB Fastening strength of naked fiber >5N Fastening strength of naked fiber holder >8N Using temperature -40 ... +75°C Repeatability (10 times) Δ IL ≤ 0.2dB Δ RL ≤ 5dB OPTICAL TRAMSMITTER 15 OT-55xx OPTICAL TRANSMITTER Features • High performance: Externally modulated technology, no laser chirp, low dispersion distortion, high extinction ratio, with excellent characteristic within 40~862MHz • AGC/MGC mode is optional at spot. OMI can be optimized at spot • 1+1 powers supply back , up hot-plug function available • The operating bandwidth is up to 47~1080MHz • CNR ≥ 53dB and excellent CTB, CSO index • SBS: 13~18dBm adjustable • ITU standard wavelength, ±200GHz (±1.6nm) adjustable • Advanced SNMP network management function • Excellent P/P ratio Product Series Model Number of output port Output power of each port OT5525HC 2 ≥4.5 OT5527HC 2 ≥7.0 OT5529HC 2 ≥8.5 OT55210HC 2 ≥ 10 OT5525HU 2 ≥4.5 OT5527HU 2 ≥7.0 OT5529HU 2 ≥8.5 OT55210HU 2 ≥ 10 Test condition: CNR1: Tx to Rx, 0dBm receiving. Operating wavelength (nm) SBS Restrain (dBm) 1548~1563 13~18 Adjustable 1528~1563nm ITU wavelength ADJ. System index (59 routes PAL-D) CNR1 CNR2 CTB CSO ≥53 ≥51.0 ≤-65 ≤-65 ≥53 ≥51.5 ≤-65 ≤-65 ≥53 ≥51.5 ≤-65 ≤-65 ≥53 ≥51.5 ≤-65 ≤-65 ≥53 ≥51.0 ≤-65 ≤-65 ≥53 ≥51.5 ≤-65 ≤-65 ≥53 ≥51.5 ≤-65 ≤-65 ≥53 ≥51.5 ≤-65 ≤-65 CNR2: 16dBm EDFA  (NF4.5~5.5dB), 65km fiber, 0dBm receiving. Specification Performance Optic feature RF feature Link feature Operating wavelength (nm) Wavelength ADJ. range (nm) Supplement HT8500HC ITU-TG.692 HT8500HU ±1.6 (±200GHz) HT8500HU Wavelength ADJ. mode   ±0.05nm stepping HT8500HU Wavelength stability (Pm/°C) -1~0 Tc=20~70°C Linewidth (MHz) Typ.=0.65 FWHM(Δλ) (-3dB full width) Side mode suppression ratio (dB) ≥45 SMSR Equivalent noise intensity (dB/Hz) ≤-160 RIN (20~1000MHz) Number of output port   2   Output power (dBm) 10, 8.5, 7.0, 4.5 2×7, 2×9, 2×10, 2×5, 4×7,6×7 Return loss (dB) ≥50   optical fiber connector   SC / APC Optional LC / APC,FC / APC Work bandwidth (MHz) 47-862 1 GHz optional Input level (dBmV) 18~28 AGC Flatness (dB) ≤±0.75 47~862MHz Return loss (dB) >16   Input impedance (Ω) 75   RF port   F-Female Transmit channel   PAL-D / 60CH   PAL-D / 99CH   CNR1 (dB) ≥53.0 ≥51.5 Back to back CNR2 (dB) ≥51.5 ≥49.5 65Km optical fiber, 0dBm receive CTB (dB) ≤-65 ≤-65   CSO (dB) ≤-65 ≤-65   SBS restrain (dBm) 13~18 Adjustable SNMP network management interface   RJ45   Communication interface Power supply General feature Index 1548~1563 Power Consume   RS232   (VAC) 90~265 50 / 60Hz (VDC) -48 30~72 (W) ≤50 Single power works Work temp. (°C) 0~50 Machine temp. control automatically Storage temp. (°C) -40~85   Operating relative humidity Size (W)x(D)x(H) (%) 5~95     483×386×44 (mm) S-Type   483×455×44 (mm) L-Type 16 EDFA / OPTICAL NODE OA-54xx FTTx EDFA Features • 1540~1563nm operating bandwidth for optical amplifier • 500~5000mW (27~37dBm) high output power • Low noise subnumber ( Typ ≤4.5dB, Max ≤5.0dB, Output ≥37dBm ) • high performance, high reliability • 8~32 uplink optical port, used in OLT • 8~32 1550nm output optical port, multiplex 1310/1490nm data stream • Can be compatible with any FTTx PON Technology: EPON/GEPON, GPON, BPON, DPON • Perfect RS232, SNMP • Efficient space, flexible installation and easy operation • Excellent P/P ratio Index Performance Optical feature Min. Supplement CATV Operation wavelength (nm) 1540   1563  CATV (nm)   1310/1490     CATV pass wavelength loss (dB)     0.8 1550nm OLT pass wavelength loss (dB)     0.8 1310/1490nm       CATV & OLT isolation (dB) 40 Number of uplink optical ports (for OLT) (pcs)  8 CATV input power (dBm) -10 ≥+3   Total output power (dBm) 27 Number of output ports (pcs)  8 Each port output power (dBm) Difference of each output power (dB) Output power adjustable range 32  +10 37 32 10   22 -0.5   +0.5   (dBm) -6   0 OA5800/P Noise figure (Pin=0dBm) (dB)   4.5 5.0 OA5837 Polarization dependence loss (dB)     0.3   Polarization dependence gain (dB)     0.4   Polarization mode dispersion (ps/nm)     0.3   Input/output isolation (dB) 30       Pump power leakage (dBm)     -30   Echo loss (dB) 55     APC  Serial interface   RS232 SNMP network management interface   RJ45 (V)       90   265 220VAC 30   72 -48VDC Power consume (W) 150   Work temp. (°C)   -5     65   Storage temp. (°C) -40   80   Relative humidity (%) 5   95 Size (W) × (D) × (H) (″) 19 × 14.3 × 1.75 / 19 × 14.7 × 3.5 ON-500 OPTICAL RECEIVER RF parameters FORWARD PATH Optical parameters • Input Wavelength • Pass wavelength: • Input power: • Optical connector: 1250 – 1600nm (ON -500/NC) 1550 ± 10 nm (ON-500/WF, ON-500/WD) 1310, 1490 nm (ON-500/WD) -11 ... -1dBm SC/APC, LC/APC Link performance • CNR (dB): • CTB (dB): • CSO (dB): Max. OLT pass wavelength Power supply General feature Typ. 52 65 65 • Test condition: PAL-59CH, OMI=3.8%, Pin=-5 dBm • Bandwidth: • Output level: • Output ports active/passive: • Output level adj.: 47 – 862 MHz 88 dBμV ( Pin: -2 dBm) 1/1 0 – 18 dB MGC OPTIONS • ON-500/NC: CATV, FTTx receiver • ON-500/WF: FTTx (1550 nm) receiver • ON-500/WD: FTTx (1550 nm) receiver with PON (1490, 1310 nm) signal pass through   1RU / 2RU OPTICAL MEASUREMENT TOM103 OPTICAL POWER METER TYPE TOM103A Calibrated Wavelength (nm) 850 / 1300 / 1310 / 1490 / 1550 / 1625 Detector type TOM103C InGaAs Measurement Range (dBm) -70 ... +10 -50 ... +30 Uncertainty (dB) ±0.1 (3.5%) linearity (dB) ±0.02 Display resolution (dB) 0.01 Frequency ID (Hz) 270, 330, 1K, 2K Wave ID (nm) 1310, 1490, 1550, 1625 Data Storage Capacity 1000 Communication Port USB Connector FC/SC/ST Interchangable Alkaline battery 3 x AA, 1.5V Power Adapter (V) 8.4 Battery Operating time (h) 200 without backlight Operation Temperature (°C) -10 ... +60 Storage Temperature (°C) -25 ... +70 Dimension (mm) 190×100×50 Weight (g) 370 TOM102 OPTICAL POWER METER TYPE TOM102A Wavelength range (nm) TOM102C 800 ~ 1700 Detector Type InGaAs Measurement Range (dBm) -70 ... +3 -50 ... +26 Uncertainty ±5% Calibrated Wavelength (nm) 850, 980 1300, 1310, 1490, 1550 Resolution 0.01dBm Operating Temperature (°C) -10 ... +60 Storage Temperature (°C) -25 ... +70 Auto-off Time (min) 10 Battery Operating Time (h) 240 Dimension (mm) 175×82×33 Power Supply alkaline battery (3xAA) Weight (g) 310 TOM101 MINI OPTICAL POWER METER TYPE TOM101A Calibrated Wavelengths (nm) Uncertainty TOM101C TOM101D 850, 980, 1310, 1550 Detector Measurement Range (dBm) TOM101B InGaAs -60 ... +3 -50 ... +10 -40 ... +20 ±5% Resolution 0.01 dBm Operating Temperature (°C) -10 ... +60 Storage Temperature (°C) -25 ... +70 Auto-off Time (min) 10 Battery Operating Time (h) 360 Power Supply alkaline battery (3xAA) Weight (g) 105 Dimension (mm) 115×60×20 -30 ... +30 17 OPTICAL MEASUREMENT 18 TOM110P GEPON OPTICAL POWER METER TYPE TOM110 PON Wavelength Pass zone (nm) Measurement Range (dBm) 1310 upstream 1490 downstream 1550 downstream 1260 ~ 1360 1470 ~ 1505 1535 ~ 1570 -40 ... +10 -40 ... +12 -40 ... +25 >40 >40 Isolation1310nm (dB) Isolation1490nm (dB) >40 Isolation1550nm (dB) >40 >40 >30 Connatural Uncertainty (dB) ±0.5 Linearity (dB) ±0.1 Pass through insertion loss (dB) <1.5 Unit dB/dBm/xW LCD display 128x64 px Resolution 0.01dB Optical Connector Interchangable FC / SC / ST Input Power Range DC 6.5V ~ 8.5V Rechargeable Battery 7.4V AC adaptor 8.4V Fiber Type 9/125µm Operating Temperature (°C) -10 ... +60 Storage Temperature (°C) -25 ... +70 Dimensions (mm) 210 x 115 x 55 (500g) Normal Optical Power meter module Measurement Range (dBm) -70 ... +6 or -50 ... +26 Connatural Uncertainty (dB) ±0.25 Linearity (dB) ±0.1 Calibration Wavelength 850, 1300, 1310, 1490, 1550, 1625 Resolution (dB) 0,01 Optical Connector FT / SC / ST Fiber type 9/125µm Visual fault locator module Output power 1mW Wavelength 650nm Optical connector FC/2.5 universal connector TOM402 FIBER RANGER TYPE TOM402 Operating Wavelength 1550±20nm LD Fiber Type 9/125µm SM Optical Connector Type FC / PC Detector Type Max. Displaying Distance InGaAs Reflection Event 60km (≥1dB) Non-reflection Event 20km (≥2.5dB) Reflection Event Dead Zone 15m Measurement Unit m Distance Accuracy (Reflection Event) ±2 + 2x10-4 x distance (m) Power Supply 3pcs AA alkaline battery Battery Operating Time ≥5000 measurements Temperature (°C) Working: -5 ... +40 / Storage: -10 ... +60 Humidity 0~85% (Non-condensation) Dimensions 190x100x50 (450g) OPTICAL MEASUREMENT TOM202 OPTICAL LIGHT SOURCE TYPE TOM202 Operating wavelengths (nm) 1310/1550, 1310/1490/1550/1625 (others specify on requests) Applicable fiber SM, MM Laser type FP-LD (others specify on requests) Output Power (dBm) -5 ~ -7 Adjustable Step (dBm) < 0.5 Adjustable Range ≥5 Stability (dB, 30min, 20°C) 0.15 Modulation (Hz) CW, 270, 330, 1K, 2K Fiber Port FC/PC Alkaline Battery 3 x AA, 1.5V Power Supply Adaptor (V) 8.4 Battery Operating time (h) 45 without backlight Operation Temperature (°C) -10 ... +60 Storage Temperature (°C) -25 ... +70 Dimension (mm) 175 x 90 x 44.5 Weight (g) 231 TOM210 PEN-TYPE VISUAL FAULT LOCATOR TYPE TOM210 Central Wavelength 650nm ± 10nm Emitter Type FP-LD Output Power 1mW, 3mW, 5mW, 10mW Optional Optical Connector 2.5mm universal connector or 1.25mm connector, FC (Male)-LC (Female) convertor can be optional Operating Model Both CW and Pulse available Pulse Frequency 2~3Hz Power Supply 2pcs AA alkaline batteries Battery Operating Time 60hours (1mW/650nm) Operating Temperature (°C) -10 ... +45 Storage Temperature (°C) -40 ... +70 Dimension (mm) Ø15x180 Weight (g) 120 TOM401 OPTICAL FIBER IDENTIFIER TYPE TOM401 Identified Wavelength Range 800 - 1700nm Identified Signal Type CW, 270Hz ± 5%, 1kHz ± 5%, 2kHz ± 5% Optical Power Reading (dBm) -50~+10 Detector Type 1mm InGaAs 2pcs Adapter Type (mm) 0.25 Applicable for Bare Fiber 0.9/2.0/3.0 Signal Direction Left & Right LED Power Display LED Signal Frequency 270Hz, 1KHz, 2KHz Operating Temperature (°C) -10 ... +60 Storage Temperature (°C) -25 ... +70 Power Supply Alkaline batteries (9V) Dimension (mm) 195x30x27 (235g) 19 For in depth information please visit our webpage Für mehr Information bitte besuchen Sie unsere Webseite AG Vorstadt 32 CH, 6304 Zug Switzerland [email protected] www.teletronik.com Your local distributor: © 23 11 2015