INDEX OPTICAL PASSIVE EQUIPMENT OPTICAL CABLES FIG8 optical cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ADSS optical cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Underground optical cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 FTTH CABLES FTTH drop cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 ODF - PATCH PANELS 19" patch panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Wall mountable patch panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 OPTICAL SPLITTERS PLC splitters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 OPTICAL CLOSURES Outdoor optical closures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Indoor optical closures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Indoor / outdoor optical closures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 OPTICAL PATCH CORDS / PIGTAILS Patch cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 OPTICAL FILTERS 1x2 triplexer filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 1x3 triplexer filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 OPTICAL ATTENUATORS & ADAPTERS Attenuators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 ACCESSORIES Fiber connector cleaner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Mechanical splice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
OPTIAL ACTIVE EQUIPMENT OPTICAL TRAMSMITTERS & RECEIVERS OT-50xx Optical transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 EDFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 ON-500 Optical receiver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 OPTICAL MEASUREMENT Optical power meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Fiber ranger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Optical light source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Visual fault locator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Optical fiber identifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
OPTICAL CABLES
3
FIG8 OPTICAL CABLE AVAILABLE MODELS
Environmental performance
Number of fibers: 4 - 6 - 8 - 12 - 16 - 24 - 36 - 48 - 64 - 72 - 96 - 144
• Temperature Performance • Installation -30ºC to +70ºC • Service -30ºC to +70ºC • Storage -30ºC to +70ºC
ELEMENTS
MATERIAL
Single Mode Optical Fibre
ITU-T G652D (made by Sumitomo)
NOMINAL VALUE
Filling Jelly
Thixotropic jelly
Central Strength Member
FRP
Core wrap
Polyester tape
Filler
Polyethylene
Rip cord
Twisted yarns (Under Sheath)
Sheating
High Density Polyethylene
Min 1.5mm (Radial thickness)
Stand wire
Steel (7 strands wire)
0.9mm diameter
Web Dimension
High Density Polyethylene
2.0 x 2.0 ± 1.0
Suspension
High Density Polyethylene
Min 1.2 mm (Nominal thickness)
Black / Natural
WIRE STRAND WEB
FILLER LOOSE TUBE WITH FIBERS & JELLY
FLOODING JELLY CENTRAL STRENGTH MEMBER
POLYSTER TAPE RIP CORD(S)
HDPE OUTER SHEATH BLACK
ADSS OPTICAL CABLE AVAILABLE MODELS
Environmental performance
Number of fibers: 4 - 8 - 12 - 24 - 36 - 48 - 64 - 72 - 96 - 144
• Temperature Performance • Installation -30ºC to +70ºC • Service -30ºC to +70ºC • Storage -30ºC to +70ºC
Tensile strength: 1.5kN - 2.0kN - 3.0kN - 4.0 kN - 5.0kN - 6.0kN
ELEMENTS
MATERIAL
Single Mode Optical Fibre
ITU-T G652D (made by Sumitomo / Furukawa)
Filling Jelly
Thixotropic jelly
Central Strength Member
FRP
Core wrap
Polyester tape
Filler
Polyethylene
Rip cord
Twisted yarns (Under Sheath)
Sheating
High Density Polyethylene
NOMINAL VALUE
Black / Natural
Min 1.5mm (Radial thickness)
ARAMID YARNS FILLER FLOODING JELLY
LOOSE TUBE WITH FIBERS & JELLY
CENTRAL STRENGTH MEMBER POLYSTER TAPE RIP CORD(S)
HDPE OUTER SHEATH BLACK
4
OPTICAL CABLES
UNDERGROUND OPTICAL CABLE (ARMOURED) AVAILABLE MODELS
Environmental performance
Number of fibers: 4 - 8 - 12 - 24 - 36 - 48 - 64 - 72 - 96 - 144
• Temperature Performance • Installation -30ºC to +70ºC • Service -30ºC to +70ºC • Storage -30ºC to +70ºC
Tensile strength: 1.5kN - 2.0kN - 3.0kN - 4.0 kN - 5.0kN - 6.0kN ELEMENTS
MATERIAL
NOMINAL VALUE
Single Mode Optical Fibre
ITU-T G652D (made by Sumitomo)
1310nm : 0.36 & 1550nm : 0.23
Filling Jelly
Thixotropic jelly
Tube
PBTP
Central Strength Member
FRP
Filler
Polyethylene
Water blocking elements
Cable Flooding Jelly
Core wrap
Polyester tape
Rip cord
Twisted yarns (Under Sheath)
Peripheral Strength Member
GFR Yarns
Armouring Tape Thickness
ECCS Tape
0,15mm (Nominal Thickness)
Outer Sheath
High Density Polyethylene
Min 1.5mm (Radial thickness)
Black / Natural
2
ECCS TAPE
FILLER
LOOSE TUBE WITH FIBERS & JELLY
FLOODING JELLY CENTRAL STRENGTH MEMBER
GFR RIP CORD(S)
HDPE OUTER SHEATH BLACK
UNDERGROUND OPTICAL CABLE (NON-ARMOURED) AVAILABLE MODELS
Environmental performance
Number of fibers: 4 - 8 - 12 - 24 - 36 - 48 - 64 - 72 - 96 - 144
• Temperature Performance • Installation -30ºC to +70ºC • Service -30ºC to +70ºC • Storage -30ºC to +70ºC
Tensile strength: 1.5kN - 2.0kN - 3.0kN - 4.0 kN - 5.0kN - 6.0kN ELEMENTS
MATERIAL
NOMINAL VALUE
Single Mode Optical Fibre
ITU-T G652D (made by Sumitomo)
1310nm : 0.36 & 1550nm : 0.23
Filling Jelly
Thixotropic jelly
Tube
PBTP
Central Strength Member
FRP
Filler
Polyethylene
FRP upcoat
Polyethylene
Water blocking elements
Cable Flooding Jelly
Core wrap
Polyester tape
Rip cord
Twisted yarns (Under Sheath)
Peripheral Strength Member
GFR Yarns
Outer Sheath
High Density Polyethylene
FILLER FLOODING JELLY
Black / Natural
2
Min 1.5mm (Radial thickness)
GFR YARNS LOOSE TUBE WITH FIBERS & JELLY
CENTRAL STRENGTH MEMBER POLYSTER TAPE RIP CORD(S)
HDPE OUTER SHEATH BLACK
FTTH CABLES
5
FTTH CABLE Description Center positioned optical fiber unit Two parallel Fiber Reinforced Plastics (FRP) Black or color LSZH sheath
Features • Special low-bend-sensitivity fiber provides high bandwidth and excellent communication transmission property • Two parallel FRP strength members ensure good performance of crush resistance to protect the fiber • Simple structure, light weight and high practicability • Novel flute design, easily strip and splice, simplify the installation and maintenance • Low smoke, zero halogen and flame retardant sheath • Single steel wire or massagers as the additional strength member ensures good performance of tensile strength
Application • CATV Fiber Optic Sensor • Fiber to Home • Telecommunication Networks • Local Area Networks (LANs)
G.652
Attenuation (+20°C)
Bandwidth (ClassA)
50/125μm
62.5/125μm
@850nm
G.655
≤3.5 dB/km
≤3.5 dB/km
@1300nm
≤1.5 dB/km
≤1.5 dB/km
@850nm
≥500 MHz·km
≥200 MHz x km
@1300nm
≥1000 MHz·km
≥600 MHz x km
0.200±0.015NA
0.275±0.015NA
@1310nm
≤0.45 dB/km
≤0.50 dB/km
@1550nm
≤0.30 dB/km
≤0.50dB/km
Numerical Aperture Cable Cut-off Wavelength λcc
Fiber Count
Cable Diameter mm
≤1260nm
Cable Weight kg/km
≤1480nm
Tensile Strength Long/Short Term N
Crush Resistance Long/Short Term N/100mm
Bending Radius Static/Dynamic mm
1
(2.0±0.2)×(3.0±0.2)
8
30/60
300/1000
15/30
2
(2.0±0.2)×(3.4±0.2)
8.5
30/60
300/1000
15/30
1
(2.0±0.2)×(3.8±0.2)
9
30/60
300/1000
15/30
4
(2.0±0.2)×(4.0±0.2)
10
30/60
300/1000
15/30
FRP STRENGTH MEMBER
OPTICAL FIBER UNIT
LSZH JACKET
FRP STRENGTH MEMBER STEEL WIRE
OPTICAL FIBER UNIT
LSZH JACKET
6
ODF - PATCH PANELS
19" PATCH PANELS
Features • Material: SPCC or AL available • Slide-out design for easy assembling • Easy and convenient 19" standard design • Cabinet surface covered with electrostatic powder coating • Bend radius of optical fiber ≥ 40mm • Variety of adaptors available
Ordering options • Number of ports • connector • Multi Mode
12 – 48 SM SC, FC , LC, E2000, PC or APC SC, FC, LC, ST
Features • Material: SPCC or AL available • Front and back side can have freely access to the cable • 19" standard design, easy and convenient on assembling • Cabinet surface covered with electrostatic powder coating • Bend radius of optical fiber ≥ 40mm • Variety of adaptors available
Ordering options • port number • connector • Multi Mode
WALL MOUNTABLE PATCH PANELS Environment Condition • Environmental temperature: -25°C ... +40°C • Relative humidity: ≤85% • Atmosphere pressure: 70~106kpa
Photoelectricity Performance • Insertion Loss: ≤0.3dB; • Echo Loss: PC≥40 dB UPC≥50 dB APC≥60 dB • Insulation resistance: >1000MΩ/500VDC • Anti-voltage: 3000VDC/1min, non puncture, no arc-over
Working Indexes • Standard work wavelength: 850nm 1310nm 1550nm • Fiber Movable Connector: up to GB/T 12507 standard • Fiber cable: up to GB/T 11819& GB/T 7424 standards
Dimensions • Specification (H x W x depth): 435×385×55mm • Capacity: 48 cores • Can let 6 fiber cables in
12 – 144 SM SC, FC , LC, E2000, PC or APC SC, FC, LC, ST
OPTICAL SPLITTERS
7
PLC SPLITTERS Features • Low Insertion Loss • Low PDL • Compact Design • Wide Operating Wavelength • Wide Operating Temperature • High Reliability and Stability • Telecordia GR-1221/1209 Compliance • Available types: filter, module, LGX, 19"
ORDERING CHOICES Available Output Channel Counts from 2, 4, 8, 16, 32 to 64 Customized Module available Connectors: SM, SC, FC, LC, E2000, PC, APC
PARAMETER
UNIT
1x2
1x4
1x8
1x16
1x32
1x64
2x2
2x4
2x8
2x16
2x32
Insertion Loss (at 23 ºC)
Max. dB
3,7
7.0
10,4
13,5
17.0
20,0
4,2
7,5
11.0
14,3
17,5
Channel Uniformity
Max. dB
0,6
0,6
1.0
1,1
1,5
1,8
1,2
1,3
1,6
1,8
2,3
Polarization Dependent Loss
Max. dB
0,15
0,15
0,2
0,2
0,2
0,3
0,3
0,3
0,3
0,4
0,4
Operating Wavelength
nm
4x7x55 (4x7x60)
4x7x55 (4x7x60)
1260 ~ 1650
Return Loss
Min. dB
55
Directivity
Min. dB
55
Operating Temperature
ºC
Storage Temperature
ºC
-40 ~ 85 -40 ~ 85
Fiber Type
Complied to G.652 D & G.657 A
Fiber Length
Customized
Package Dimensions (T x W x L) Note:
mm
4x4x40
4x5x45 (4x4x40)
4x7x55 (4x7x60)
4x12x60
4x5x45
1. All measurement were done at room temperature without connectors. 2. The above spec. is under no connector. If including connector, IL, UL and PDL would increase 0.5dB, 0.2dB and 0.05dB respectively.
OUTDOOR OPTICAL CLOSURES
8
OPTICAL CLOSURES KD 144
KDJ 144
KDJ 120
KDJ 408
OPTIONAL SEALING ADAPTERS
KD 60
KDJ120 2-4 DOME TYPE 2+4 CABLE INLETS • Universal design (could be used for different sizes of cables; both single core and ribbon fibers; pole-mounting, aerial, and direct buried applications) • Designed for installing SC adapters & splitters • For installing various cables see optional sealing adapters Fibers/Tray
Max capacity (F)
Ports
Suitable Dia of cable (mm)
SC adapters
Sealing structure
Size & weight
24
120
2+4
Ø3 - Ø13.2 (depending on sealing)
Max. 36
In-line mechanical sealing
480 × Ø250 / 5.8kg
KDJ144 1-4
DOME TYPE 1+4 CABLE INLETS
• Universal design (could be used for different sizes of cables; both single core and ribbon fibers; pole-mounting, aerial, and direct buried applications) • Adequate space for storage of fibers • For installing various cables see optional sealing adapters Fibers/Tray
Max capacity (F)
Ports
Suitable Dia of cable (mm)
SC adapters
Sealing structure
Size & weight
24
144
1+4
Ø3 - Ø24 (depending on sealing)
Max. 36
In-line mechanical sealing
450 × Ø230 / 4.2kg
KDJ408 2-4 DOME TYPE 2+4 CABLE INLETS • Universal design (could be used for different sizes of cables; both single core and ribbon fibers; pole-mounting, aerial, and direct buried applications) • Adequate space for storage of fibers • For installing various cables see optional sealing adapters Fibers/Tray
Max capacity (F)
Ports
Suitable Dia of cable (mm)
Sealing structure
Size & weight
12
408
2+4
Ø8 - Ø17.5 (depending on sealing)
In-line mechanical sealing
480 × Ø250 / 6.5kg
KD60 6
SMALL SIZE FTTH CLOSURE
• Small size with numeral cable ports and functions • 5 regular cable ports, 1 testing port, 4 pigtail outlets • Unique sealing method (could be reused many times) • Aerial, pole-mounting, direct buried, wall-mounting applications • Designed for installing SC adapters & splitters • Optional sealing adapter for 24pcs of FIG8 soft cable Fibers/Tray
Max capacity (F)
Ports
Suitable Dia of cable (mm)
Sealing structure
Size & weight
12
60
5+4
Ø2 - Ø15 (depending on sealing)
In-line mechanical sealing
300×220×100 / 2.7kg
KD144 1-4 DOME TYPE 1+4 CABLE INLETS • Universal design (could be used for different sizes of cables; both single core and ribbon fibers; pole-mounting, aerial, and direct buried applications) • Adequate space for storage of fibers • Designed for installing splitters Fibers/Tray
Max capacity (F)
Ports
Suitable Dia of cable (mm)
SC adapters
Sealing structure
Size & weight
24
144
1+4
Ø8 - Ø17.5
Max. 18
Heat shrink sealing
450 × Ø230 / 4.2kg
OPTIONAL SEALING ADAPTERS KDS 01
KDS 02
KDS 03
KDS 04
KDS 05
8pcs of Ø3mm soft cable
8pcs of FIG8 soft cable
6pcs of self support soft cable
4pcs of Ø5 - Ø7mm cable
16pcs of Ø5 - Ø7mm cable
INDOOR OPTICAL CLOSURES
9
INDOOR OPTICAL CLOSURES
FTTH WALL OUTLET
KDI 12
KDI 96 KDI 4
KDI 96 INDOOR SPLICE CLOSURE • Indoor design • Prepared for adapter installation • Prepared for splitter installation • High capacity • Universal cable port for numerous drop cables Fibers/Tray
Max capacity (F)
Suitable Dia of cable (mm)
Dimensions (W x L x H)
Adapter type
24
96
Ø3 - Ø18
180 x 378 x 74mm
SC, LC, FC
KDI 12 INDOOR-OUTDOOR TERMINAL BOX 3 PORTS • Outdoor design protection grade IP65 • Prepared for adapter installation (SC 8 pieces) • Prepared for splitter installation • Optional universal cable ports Fibers/Tray
Max capacity (F)
Suitable Dia of cable (mm)
Dimensions (W x L x H)
Adapter type
12
12
Ø3 - Ø13
220 x 180 x 50mm
SC
KDI 4 INDOOR TERMINAL BOX • Small size • Low price • Prepared for adapter installation (SC 4 pieces) Fibers/Tray
Max capacity (F)
Suitable Dia of cable (mm)
Dimensions (W x L x H)
Adapter type
4
4
Ø1 - Ø5
150 x 110 x 30mm
SC
FTTH JUNCTION BOX • Small size • Low price • Prepared for adapter installation Fibers/Tray
Max capacity (F)
Suitable Dia of cable (mm)
Dimensions (W x L x H)
Adapter type
2
2
Ø1 - Ø5
86 x 86 x 45mm
SC
10
INDOOR OPTICAL CLOSURES
INDOOR / OUTDOOR OPTICAL CLOSURES
KDI 24
KDI 24-S KDI 24 TERMINAL BOX • Applicable for inside and outside installation • Protective grade IP65 • It’s applicable to install up to 6 pieces of SC duplex or 6pcs of 4 fibers LC adapters • Suitable for 2x1/16 PLC installation Fibers/Tray
Max capacity (F)
Suitable Dia of cable (mm)
Dimensions (W x L x H)
Adapter type
24
24
Ø1,8 - Ø11
258×186×61mm
SC, LC
KDI 24-S FIBER OPTIC DISTRIBUTION BOX • Indoor / outdoor • Prepared for adapter installation • Prepared for splitter installation • High capacity • Cable parts for uncutted cables • 16 ports for drop cables Fibers/Tray
Max capacity (F)
Suitable Dia of cable (mm)
Dimensions (W x L x H)
Adapter type
24
24
Ø2 - Ø18
292 x 248 x 100mm
SC, LC
OPTICAL PATCH CORDS / PIGTAILS
11
PATCH CORDS Features • Variety of connectors available • Simplex or duplex • SM or MM • Various cable lenghts • Fan-out option • ITU-G6520 or G657A optional
POLISHING PC
APC
PC
Mode
SM
SM
MM
Insertion Loss (dB)
≤ 0.2
≤ 0.2
≤ 0.3
Return Loss dB)
≥ 45
≥ 60
Repeatability dB)
≥ 35 ≤ 0.1
Changeability (dB)
≤ 0.2
Storage Temp ( ºC )
-40 ~ +85
Operating Temp ( ºC )
-10 ~ +75
AVAILABLE CONNECTORS (SM, 9/125)
(MM, 50/125 or 62,5/125)
SC/PC
SC
SC/APC
FC
FC/PC
LC
ORDERING CHOICES
FC/APC
ST
Simplex/Duplex patch cord
ST/PC
E2000
Pigtails Various boot cable sizes
LC/PC
0.9mm
LC/APC E2000/APC E2000/PC
FC
SC
LC
E2000
LC duplex
ST
2mm
3mm
12
OPTICAL FILTERS
1X2 TRIPLEXER FILTER Features • Wide pass band • High isolation • Low insertion loss
PARAMETERS
1×2 TriPlexer Filter
Central wavelength (nm)
1310, 1490, 1550
Operating Wavelength (nm)
1310±40, 1490±10 , 1550±10
Pass/Reflection wavelength (nm)
On customer request
Pass band insertion loss (nm)
≤0.8 (0.6 typical)
Reflection band insertion loss (dB)
≤0.6 (0.4 typical)
Pass band isolation (dB)
≥30
Reflection band isolation (dB)
≥15
Directivity (dB)
≥55
Return loss (dB)
≥50
PDL (dB)
≤0.1
Wavelength thermal stability (nm/ °C)
≤0.003
Insertion loss thermal stability (dB/ °C)
≤0.005
Power handling (Mw)
≤500
Operating temperature (°C)
-40 ~ +85
Storage temperature (°C)
-40 ~ +85
Dimensions (mm)
Ф5.5× L34
Ф5.5 COMMON PORT PASS PORT
REFLECTION PORT 34 55
1X3 TRIPLEXER FILTER Features • Splitting all three wavelengths • compact size • Wide pass band • High isolation • Low insertion loss
PARAMETERS
1×3 TriPlexer Filter
Central wavelength (nm)
1310, 1490, 1550
Operating Wavelength (nm)
1310±40, 1490±10 , 1550±10
Pass/Reflection wavelength (nm)
1490 ± 10/1310 ±40 , 1550 ± 10
Pass band insertion loss (nm)
≤0.8 (0.6 typical)
Reflection band insertion loss (dB)
≤1.0 (0.8 typical)
Pass band isolation (dB)
≥30
Reflection band isolation (dB)
≥15
Directivity (dB)
≥55
Return loss (dB)
≥50
PDL (dB)
≤0.1
Wavelength thermal stability (nm/ °C)
≤0.003
Insertion loss thermal stability (dB/ °C)
≤0.005
Power handling (Mw)
≤500
Operating temperature (°C)
0 ~ +75
Storage temperature (°C)
-40 ~ +85
Dimensions (mm)
Ф5.5×L50
1310 nm
Ф5.5
1490 nm
COMMON
1550 nm
50 68
OPTICAL ATTENUATORS & ADAPTERS
13
ATTENUATORS Features • High return loss • High power endurance • Wavelength independent • Low PDL • Precise control of attenuation range • Simple manipulation
OPTICAL ATTENUATORS (PLUG-IN & ADAPTER TYPE) SC/PC SC/APC FC/PC FC/APC ST/PC LC/PC LC/APC E2000/APC
PARAMETER
UNIT
DESCRIPTION Adapter type
Plug-in type
Operation Wavelength
nm
1310, 1550 nm
Attenuator Value
dB
1,2,3 to 30 (base on your request)
Attenuator Precision
dB
Max. PDL
dB
Return Loss
dB
Operating Temperature
ºC
-40~+75
Storage Temperature
ºC
-40~+75
+/-0.5 (attenuation<10) +/-1.0 (attenuation>10) 0,1 40 PC/65 APC
40 PC/65 APC
ADAPTERS Features • Low insertion and back reflection loss • High precision alignment • Compact design • Zirconia ( SM ) or bronze ( MM ) sleeve
PARAMETER
UNIT
Sleeve Operation Wavelength
nm
Insertion Loss
dB
Connection Durability
Times
DESCRIPTION SMPC
SMAPC
MM
Zirconia
Zirconia
Phosphor Bronze
1200~1600 0,2
850 0,2
0,3
1000 Mating
Operating Temperature
ºC
-40~+80
Storage Temperature
ºC
-40~+85
Relative Humidity
%
95
HYBRID ADAPTERS
SM-PC & APC ADAPTERS
SC-FC
SC/APC-FC/APC
Simplex
SC-LC
SC/APC-FC/PC
SC
SC-E2000
SC/APC-LC/PC
FC
FC-LC
SC/APC-LC/APC
LC
FC-E2000
SC/APC/-E2000/APC
ST
LC-E2000
LC/PC-SC/PC
E2000
Duplex SC
LC
ACCESSORIES
14
FIBER CONNECTOR CLEANER Features • Safe and environment friendly • Safe to operator and no hazard to environment, no ESD contamination • Fast, effective, repeatable cleanings • Over 500 cleaning times • It is also suitable for fiber optic construction, maintenance, and equipment manufacture • It can be used for SC, FC, ST, D4, LC, DIN and Bionic connectors. • Cleaning tape is replaceable
TYPE
FIBER CONNECTOR CLEANER
Cleaning Times
Over 500 times per reel
Cleaning Result
-20 ... -50 dB (Return Loss)
Operating Temperature
-10 ... +50°C
Weight
100 g
MECHANICAL SPLICE ITEM
TECHNICAL PARAMETERS
Applicable for
φ0.25 mm & φ0.90 mm Fiber
Optical fiber diameter
125μm (657A & 657B)
Tight buffer diameter (μm)
250μm & 900μm
Fiber mode
Single & multi mode
Operation time
About 10s (no fiber cut)
Average Insert loss
≤ 0.2dB (1310nm & 1550nm)
Return loss
≤ -40dB
Fastening strength of naked fiber
>5N
Fastening strength of naked fiber holder
>8N
Using temperature
-40 ... +75°C
Repeatability (10 times)
Δ IL ≤ 0.2dB Δ RL ≤ 5dB
OPTICAL TRAMSMITTER
15
OT-55xx OPTICAL TRANSMITTER Features • High performance: Externally modulated technology, no laser chirp, low dispersion distortion, high extinction ratio, with excellent characteristic within 40~862MHz • AGC/MGC mode is optional at spot. OMI can be optimized at spot • 1+1 powers supply back , up hot-plug function available • The operating bandwidth is up to 47~1080MHz • CNR ≥ 53dB and excellent CTB, CSO index • SBS: 13~18dBm adjustable • ITU standard wavelength, ±200GHz (±1.6nm) adjustable • Advanced SNMP network management function • Excellent P/P ratio
Product Series Model
Number of output port
Output power of each port
OT5525HC
2
≥4.5
OT5527HC
2
≥7.0
OT5529HC
2
≥8.5
OT55210HC
2
≥ 10
OT5525HU
2
≥4.5
OT5527HU
2
≥7.0
OT5529HU
2
≥8.5
OT55210HU
2
≥ 10
Test condition:
CNR1: Tx to Rx, 0dBm receiving.
Operating wavelength (nm)
SBS Restrain (dBm)
1548~1563 13~18 Adjustable 1528~1563nm ITU wavelength ADJ.
System index (59 routes PAL-D) CNR1
CNR2
CTB
CSO
≥53
≥51.0
≤-65
≤-65
≥53
≥51.5
≤-65
≤-65
≥53
≥51.5
≤-65
≤-65
≥53
≥51.5
≤-65
≤-65
≥53
≥51.0
≤-65
≤-65
≥53
≥51.5
≤-65
≤-65
≥53
≥51.5
≤-65
≤-65
≥53
≥51.5
≤-65
≤-65
CNR2: 16dBm EDFA (NF4.5~5.5dB), 65km fiber, 0dBm receiving.
Specification Performance
Optic feature
RF feature
Link feature
Operating wavelength
(nm)
Wavelength ADJ. range
(nm)
Supplement HT8500HC
ITU-TG.692
HT8500HU
±1.6 (±200GHz)
HT8500HU
Wavelength ADJ. mode
±0.05nm stepping
HT8500HU
Wavelength stability
(Pm/°C)
-1~0
Tc=20~70°C
Linewidth
(MHz)
Typ.=0.65
FWHM(Δλ) (-3dB full width)
Side mode suppression ratio
(dB)
≥45
SMSR
Equivalent noise intensity
(dB/Hz)
≤-160
RIN (20~1000MHz)
Number of output port
2
Output power
(dBm)
10, 8.5, 7.0, 4.5
2×7, 2×9, 2×10, 2×5, 4×7,6×7
Return loss
(dB)
≥50
optical fiber connector
SC / APC
Optional LC / APC,FC / APC
Work bandwidth
(MHz)
47-862
1 GHz optional
Input level
(dBmV)
18~28
AGC
Flatness
(dB)
≤±0.75
47~862MHz
Return loss
(dB)
>16
Input impedance
(Ω)
75
RF port
F-Female
Transmit channel
PAL-D / 60CH
PAL-D / 99CH
CNR1
(dB)
≥53.0
≥51.5
Back to back
CNR2
(dB)
≥51.5
≥49.5
65Km optical fiber, 0dBm receive
CTB
(dB)
≤-65
≤-65
CSO
(dB)
≤-65
≤-65
SBS restrain
(dBm)
13~18
Adjustable
SNMP network management interface
RJ45
Communication interface Power supply
General feature
Index 1548~1563
Power Consume
RS232
(VAC)
90~265
50 / 60Hz
(VDC)
-48
30~72
(W)
≤50
Single power works
Work temp.
(°C)
0~50
Machine temp. control automatically
Storage temp.
(°C)
-40~85
Operating relative humidity Size (W)x(D)x(H)
(%)
5~95
483×386×44 (mm)
S-Type
483×455×44 (mm)
L-Type
16
EDFA / OPTICAL NODE
OA-54xx FTTx EDFA Features • 1540~1563nm operating bandwidth for optical amplifier • 500~5000mW (27~37dBm) high output power • Low noise subnumber ( Typ ≤4.5dB, Max ≤5.0dB, Output ≥37dBm ) • high performance, high reliability • 8~32 uplink optical port, used in OLT • 8~32 1550nm output optical port, multiplex 1310/1490nm data stream • Can be compatible with any FTTx PON Technology: EPON/GEPON, GPON, BPON, DPON • Perfect RS232, SNMP • Efficient space, flexible installation and easy operation • Excellent P/P ratio Index
Performance
Optical feature
Min.
Supplement
CATV Operation wavelength
(nm)
1540
1563
CATV
(nm)
1310/1490
CATV pass wavelength loss
(dB)
0.8
1550nm
OLT pass wavelength loss
(dB)
0.8
1310/1490nm
CATV & OLT isolation
(dB)
40
Number of uplink optical ports (for OLT)
(pcs)
8
CATV input power
(dBm)
-10
≥+3
Total output power
(dBm)
27
Number of output ports
(pcs)
8
Each port output power
(dBm)
Difference of each output power
(dB)
Output power adjustable range
32 +10 37 32
10
22
-0.5
+0.5
(dBm)
-6
0
OA5800/P
Noise figure (Pin=0dBm)
(dB)
4.5
5.0
OA5837
Polarization dependence loss
(dB)
0.3
Polarization dependence gain
(dB)
0.4
Polarization mode dispersion
(ps/nm)
0.3
Input/output isolation
(dB)
30
Pump power leakage
(dBm)
-30
Echo loss
(dB)
55
APC
Serial interface
RS232
SNMP network management interface
RJ45
(V)
90
265
220VAC
30
72
-48VDC
Power consume
(W)
150
Work temp.
(°C)
-5
65
Storage temp.
(°C)
-40
80
Relative humidity
(%)
5
95
Size (W) × (D) × (H)
(″)
19 × 14.3 × 1.75 / 19 × 14.7 × 3.5
ON-500 OPTICAL RECEIVER RF parameters
FORWARD PATH
Optical parameters • Input Wavelength • Pass wavelength: • Input power: • Optical connector:
1250 – 1600nm (ON -500/NC) 1550 ± 10 nm (ON-500/WF, ON-500/WD) 1310, 1490 nm (ON-500/WD) -11 ... -1dBm SC/APC, LC/APC
Link performance • CNR (dB): • CTB (dB): • CSO (dB):
Max.
OLT pass wavelength
Power supply General feature
Typ.
52 65 65
• Test condition: PAL-59CH, OMI=3.8%, Pin=-5 dBm
• Bandwidth: • Output level: • Output ports active/passive: • Output level adj.:
47 – 862 MHz 88 dBμV ( Pin: -2 dBm) 1/1 0 – 18 dB MGC
OPTIONS • ON-500/NC: CATV, FTTx receiver • ON-500/WF: FTTx (1550 nm) receiver • ON-500/WD: FTTx (1550 nm) receiver with PON (1490, 1310 nm) signal pass through
1RU / 2RU
OPTICAL MEASUREMENT TOM103 OPTICAL POWER METER TYPE
TOM103A
Calibrated Wavelength (nm)
850 / 1300 / 1310 / 1490 / 1550 / 1625
Detector type
TOM103C InGaAs
Measurement Range (dBm)
-70 ... +10
-50 ... +30
Uncertainty (dB)
±0.1 (3.5%)
linearity (dB)
±0.02
Display resolution (dB)
0.01
Frequency ID (Hz)
270, 330, 1K, 2K
Wave ID (nm)
1310, 1490, 1550, 1625
Data Storage Capacity
1000
Communication Port
USB
Connector
FC/SC/ST Interchangable
Alkaline battery
3 x AA, 1.5V
Power Adapter (V)
8.4
Battery Operating time (h)
200 without backlight
Operation Temperature (°C)
-10 ... +60
Storage Temperature (°C)
-25 ... +70
Dimension (mm)
190×100×50
Weight (g)
370
TOM102 OPTICAL POWER METER TYPE
TOM102A
Wavelength range (nm)
TOM102C 800 ~ 1700
Detector Type
InGaAs
Measurement Range (dBm)
-70 ... +3
-50 ... +26
Uncertainty
±5%
Calibrated Wavelength (nm)
850, 980 1300, 1310, 1490, 1550
Resolution
0.01dBm
Operating Temperature (°C)
-10 ... +60
Storage Temperature (°C)
-25 ... +70
Auto-off Time (min)
10
Battery Operating Time (h)
240
Dimension (mm)
175×82×33
Power Supply
alkaline battery (3xAA)
Weight (g)
310
TOM101 MINI OPTICAL POWER METER TYPE
TOM101A
Calibrated Wavelengths (nm)
Uncertainty
TOM101C
TOM101D
850, 980, 1310, 1550
Detector Measurement Range (dBm)
TOM101B
InGaAs -60 ... +3
-50 ... +10
-40 ... +20 ±5%
Resolution
0.01 dBm
Operating Temperature (°C)
-10 ... +60
Storage Temperature (°C)
-25 ... +70
Auto-off Time (min)
10
Battery Operating Time (h)
360
Power Supply
alkaline battery (3xAA)
Weight (g)
105
Dimension (mm)
115×60×20
-30 ... +30
17
OPTICAL MEASUREMENT
18
TOM110P GEPON OPTICAL POWER METER TYPE
TOM110 PON
Wavelength Pass zone (nm) Measurement Range (dBm)
1310 upstream
1490 downstream
1550 downstream
1260 ~ 1360
1470 ~ 1505
1535 ~ 1570
-40 ... +10
-40 ... +12
-40 ... +25
>40
>40
Isolation1310nm (dB) Isolation1490nm (dB)
>40
Isolation1550nm (dB)
>40
>40 >30
Connatural Uncertainty (dB)
±0.5
Linearity (dB)
±0.1
Pass through insertion loss (dB)
<1.5
Unit
dB/dBm/xW
LCD display
128x64 px
Resolution
0.01dB
Optical Connector
Interchangable FC / SC / ST
Input Power Range
DC 6.5V ~ 8.5V
Rechargeable Battery
7.4V
AC adaptor
8.4V
Fiber Type
9/125µm
Operating Temperature (°C)
-10 ... +60
Storage Temperature (°C)
-25 ... +70
Dimensions (mm)
210 x 115 x 55 (500g)
Normal Optical Power meter module Measurement Range (dBm)
-70 ... +6 or -50 ... +26
Connatural Uncertainty (dB)
±0.25
Linearity (dB)
±0.1
Calibration Wavelength
850, 1300, 1310, 1490, 1550, 1625
Resolution (dB)
0,01
Optical Connector
FT / SC / ST
Fiber type
9/125µm
Visual fault locator module Output power
1mW
Wavelength
650nm
Optical connector
FC/2.5 universal connector
TOM402 FIBER RANGER TYPE
TOM402
Operating Wavelength
1550±20nm LD
Fiber Type
9/125µm SM
Optical Connector Type
FC / PC
Detector Type Max. Displaying Distance
InGaAs Reflection Event
60km (≥1dB)
Non-reflection Event
20km (≥2.5dB)
Reflection Event Dead Zone
15m
Measurement Unit
m
Distance Accuracy (Reflection Event)
±2 + 2x10-4 x distance (m)
Power Supply
3pcs AA alkaline battery
Battery Operating Time
≥5000 measurements
Temperature (°C)
Working: -5 ... +40 / Storage: -10 ... +60
Humidity
0~85% (Non-condensation)
Dimensions
190x100x50 (450g)
OPTICAL MEASUREMENT TOM202 OPTICAL LIGHT SOURCE TYPE
TOM202
Operating wavelengths (nm)
1310/1550, 1310/1490/1550/1625 (others specify on requests)
Applicable fiber
SM, MM
Laser type
FP-LD (others specify on requests)
Output Power (dBm)
-5 ~ -7
Adjustable Step (dBm)
< 0.5
Adjustable Range
≥5
Stability (dB, 30min, 20°C)
0.15
Modulation (Hz)
CW, 270, 330, 1K, 2K
Fiber Port
FC/PC
Alkaline Battery
3 x AA, 1.5V
Power Supply Adaptor (V)
8.4
Battery Operating time (h)
45 without backlight
Operation Temperature (°C)
-10 ... +60
Storage Temperature (°C)
-25 ... +70
Dimension (mm)
175 x 90 x 44.5
Weight (g)
231
TOM210 PEN-TYPE VISUAL FAULT LOCATOR TYPE
TOM210
Central Wavelength
650nm ± 10nm
Emitter Type
FP-LD
Output Power
1mW, 3mW, 5mW, 10mW Optional
Optical Connector
2.5mm universal connector or 1.25mm connector, FC (Male)-LC (Female) convertor can be optional
Operating Model
Both CW and Pulse available
Pulse Frequency
2~3Hz
Power Supply
2pcs AA alkaline batteries
Battery Operating Time
60hours (1mW/650nm)
Operating Temperature (°C)
-10 ... +45
Storage Temperature (°C)
-40 ... +70
Dimension (mm)
Ø15x180
Weight (g)
120
TOM401 OPTICAL FIBER IDENTIFIER TYPE
TOM401
Identified Wavelength Range
800 - 1700nm
Identified Signal Type
CW, 270Hz ± 5%, 1kHz ± 5%, 2kHz ± 5%
Optical Power Reading (dBm)
-50~+10
Detector Type
1mm InGaAs 2pcs
Adapter Type (mm)
0.25 Applicable for Bare Fiber 0.9/2.0/3.0
Signal Direction
Left & Right LED
Power Display
LED
Signal Frequency
270Hz, 1KHz, 2KHz
Operating Temperature (°C)
-10 ... +60
Storage Temperature (°C)
-25 ... +70
Power Supply
Alkaline batteries (9V)
Dimension (mm)
195x30x27 (235g)
19
For in depth information please visit our webpage Für mehr Information bitte besuchen Sie unsere Webseite
AG Vorstadt 32 CH, 6304 Zug Switzerland
[email protected] www.teletronik.com
Your local distributor:
© 23 11 2015