TEMPORARY MX21TG VE01 200-220/230V 50/60Hz ~1 COMPRESSOR Displacement (cm3) Diameter (mm) Stroke (mm) Net Weight (Kg) Oil type Oil charge (cm3)
20.72 34.93 21.62 17.5 ISO VG 46 ESTER 500
MOTOR Approximate Power (CV) Voltage/Frequency (V/Hz) Voltage range (V) Code Type Phase number Locked rotor current (A) Main W. resist. at 25ºC (Ω) Start W. resist. at 25ºC (Ω)
1 200V 50Hz 170-242 82.219 CSR 1 PH 37.0 1.56 5.5
APPLICATION Application Refrigerant Evaporating (°C) Expansion Comp. cooling Max. ambient temp. (°C) NOMINAL PERFORMANCE Cooling capacity (kcal/h) Input power (W) EER (kcal/Wh) COP (W/W) Current (A) TEST CONDITIONS Evaporating temp. (°C) Condensing temp. (°C) Liq.t. entering expan. (°C) Ambient t. and return (°C) Tens/Freq (V/Hz)
ELECTRICAL COMPONENTS Relay Pick-Up (A) Drop-Out (A) Protector Current (A) Time check (seg) Disc temp. (Open/Close) (°C) Starting capacitor (µF/V)F/V) Run capacitor (µF/V)
3ARR3 10S3 180-195 40-105 MRA38142 24.0 7.5-14 120.0 / 52.0 72- 88 / 330 20 / 400
High/Mid. back pressure R404A -20 to 10 Capillar/Valve Fan cooled 43 CYCLE C 2085 1374 1.51 1.76 7.07 5.0 55.0 55.0 32.0 200V 50Hz
CYCLE D 2620 1415 1.85 2.15 7.30 7.2 55.0 46.0 35.0 200V 50Hz
RVA 3AG.. 180-195 40-105 T0257/G. 24.0 7.5-14 120.0 / 52.0
DIMENSIONS AND ELECTRICAL DIAGRAM 1 2 3
DOC 080409
DESIGNATION Service Suction Discharge
INTERNAL DIAM. (MM) 9,7 9.7 6.5
1/2
TECHNICAL DATA SHEET
TEMPORARY MX21TG VE01 200-220/230V 50/60Hz ~1
TEST CONDITIONS Voltage/frequency Ambient t. and return Liq.t. entering expan.
200V 50Hz 35 °C Subcooling 9 K
MASS FLOW
INTENSITY
CONSUMPTION
COOLING CAPACITY
DOC 080409