Preview only show first 10 pages with watermark. For full document please download

Terminal Manager Pin - Honeywell Process Solutions

   EMBED


Share

Transcript

RC500 Remote Terminal Unit Designed to withstand the toughest environments and very low power requirements, Honeywell’s RC500 RTU is a modular and scalable controller capable of all remote automation and control applications. The RC500 RTU, combined with Honeywell’s powerful and feature-rich SCADA products, provides an integrated solution solving complex remote automation requirements Multiple RTU Models to Suit Specific Application Needs Flexible Communication Ports and Protocol Options RC500 offers the flexibility to choose the appropriate RTU model to suit specific application needs. RTU variants are available based upon the number of communication ports needed, memory requirements, system topology needs, protocol needs and type of input/output modules needed. RC500 RTUs have the power of embedded Linux platform and are capable of all remote automation and control applications RC500 RTUs have a variety of communication ports – RS232, RS485 and Ethernet ports. An RTU model with multiple ethernet ports enables dual Ethernet configuration, integration with other controllers and SCADA Servers. RC500 Ethernet ports enable easy I/O expansion through connectivity to Ethernet I/Os. RC500 supports industry standard protocols Modbus and DNP3 over Serial and Ethernet. Simple I/O Transfers Enable Easy Information Exchange RC500 RTUs allow simple and fast configuration of I/O transfers to peer RTUs. An I/O transfer is a way of copying input or output values from one RTU to another. I/O can be transferred to/from an external device (I/O module or RTU/PLC) or within the local RTU itself. This allows easy transfer and sharing of information between devices in a large network. Peer-to-Peer I/O transfers Robust Datalogging Ensures Data Availability Endures Tough Environments and Low Power Situations RC500 has been designed to withstand the toughest environments most suited for remote automation needs such as in oil and gas applications. RC500 can operate on very low power suitable for solar power in remote applications. RC500 has datalogging capabilities that provide the ability to record I/O values and log them into data files. This ensures important field data is never missed and is available for analysis. The data files can be retrieved and then displayed or imported by many Windows applications. RC500 can log data continuously at a pre-defined interval or datalogging can be event-triggered by a program. RC500 Remote Terminal Unit 2 Integrated Solution Answers Complex Automation Needs RC500 I/O Toolkit Simplifies RTU and I/O Configuration RC500 RTU, when combined with powerful Experion SCADA products, provides an integrated solution for complex remote automation and control needs such as in oil and gas applications. RTU integrates into Honeywell’s Experion using industry standard protocols such as Modbus and DNP3. This seamless RTU integration with Experion answers the most critical and complex automation needs and at the same time brings in all the latest technology that the Experion platform offers. The RC500 I/O Toolkit is an easy-to-use software package for designing, configuring and maintaining RC500 RTUs and I/O. The basic level lets you configure RTUs and I/O, assign tag names and configure modes of operation for various RC500 systems. The optional feature sets add exporting, datalogging, Linux features and other rich functionalities to your system. This software also enables easy configuration of I/O transfers between RTUs. RC500 I/O Toolkit Experion Station Redundant Experion SCADA 127 RC500 Engineering Station RC500 I/O Toolkit & ISAGRAF Modbus/DNP3 RC500 RTU RC500 Ethernet I/O RC500 Ethernet I/O ISAGRAF Enables Effective and Fast RTU Programming Scalable Architecture and Flexible I/O Expansion Options RC500 RTU provides flexibility in I/O expansion on Ethernet. The RC500 Ethernet I/O family consists of Ethernet I/O-1 and Ethernet I/O-2 with each offering a range of features and functions. The RC500 Ethernet I/O-2 is the next generation of process quality I/O that offers the best price/performance for control applications. These I/O modules offer several benefits such as redundant power survivability, self-resetting fuses, independent watchdog for health monitoring and many more. There are easy to view LEDs that provide complete status information. The Ethernet I/O modules also have RS485 and USB ports for flexibility and allow hot swapping for instant installation and maintenance. The Ethernet I/O-2 family also offers a full range of analog and discrete I/O module types with several features such as 32 I/O channel in a space saving package, flexible mix of I/O functions in a single module, 16-bit analog for extreme accuracy, very fast I/O polling, advanced counter functions and watchdog monitoring. ISAGRAF programming for RC500 provides all IEC 61131 standard programming languages: Sequential Function Chart, Ladder Diagram, Structured Text, Instruction List and Function Block Diagram and Flow Charting Graphical Programming: ISaGRAF combines ladder logic with powerful function blocks to give you the simplicity of a PLC, and the performance of a high-end process controller. Text Programming: IEC 1131 statement language uses simple text that is easy to learn and maintain. Multi-Tasking Organization: Sequential Function Charts organize your programs into tasks or sequential steps. Each SFC block may be a ladder diagram, function diagram, statement program or instruction list. On-Line Program Changes: Improve processes without waiting for shutdowns. The ISaGRAF "Workbench" lets you make program changes on the fly. Program Simulation: ISaGRAF has a program simulator that shows how your program works before the actual startup. You can develop and debug your programs quickly and easily and then load them to a RC500 programmable node Direct RC500 tag references: The tag names from the RC500 I/O Toolkit configuration appear automatically in ISaGRAF. They flow automatically to your program logic, saving significant programming time. RC500 Remote Terminal Unit 3 RC500 Specification Summary RC500 RTU Models & Technical Specifications RC500 RTU Models Ports RC-SCONTRL RC-VCONTRL RC-MVACONTRL RC-MVBCONTRL Note Ethernet 5 1 1 1 RS232 2 3 2 2 On-board I/O RD485 1 1 2 1 DI 12 12 DO 4 8 AI 8 6 Memory AO 2 - Datalogging 2M 512K 512K 512K Program Flash 128M 16M 64M 64M DRAM 64M 16M 32M 32M RC-MVxCONTRL RTU models include in-built DNP3 & AGA options RC500 Technical Specifications General Operating System I/O Expansion Industrial Power PC (32 bit data bus) Embedded LINUX Ethernet I/O Number of applications allowed IEC 61131 Open programming Languages supported Memory dependant ISaGRAF Software FBD (Function Block Diagram) Quick LD SFC ST IL Watchdogs and Monitors CPU Watchdog Communication Watchdog Heartbeat Watchdog Ethernet Port For run-time diagnostics :Ladder Logic :Sequential Flow Chart :Structured Text :Instruction List CPU automatically resets if error is detected; status LED flashes error code Settable timeout and output action (force off or freeze) Settable timeout and output action (force off or freeze) 10/100BaseTx (auto-detect) Connection Protocols supported RJ45 (auto-crossover) TCP/IP, ARP, UDP, ICMP, DHCP RS485 Port A RS232 Port B RS485 Port C RS232 Port D Screws (GND, 485+, 485-, termination) (2-wire Half-duplex) RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR/RI, GND) Screws (GND, 485+, 485-, termination) (2-wire Half-duplex) Screws (TD, RD, RTS, GND) Protocols DNP 3.0 Serial Modbus RTU/ASCII Serial DNP 3.0 TCP/IP Modbus RTU/ASCII TCP/IP Serial Ports Protocols supported Environmental Input Power Temperature Humidity RC500 Ethernet I/O-1 Technical Specifications Ethernet I/O-1 Ethernet Port Isolation RS485 port Protocol 300 to 115200 baud Serial / Ethernet DIN rail or flat panel mount 10-30 VDC @ 100 ma (typical) -40 to 70 DegC (Operational) -40 to 85 DegC (Storage) 5% to 95% RH (non-condensing) Full line of analog and discrete I/O Ethernet port 10BaseT at 10 Mbps 1200 Volts RMS 1 minute Up to 38400 baud Modbus RC500 Remote Terminal Unit RC500 Ethernet I/O-2 Technical Specifications Ethernet I/O-2 Ethernet Port Isolation RS485 port Protocol RC500 I/O Toolkit Software RTU & I/O Configuration Software Operating System Hardware RC500 I/O Toolkit (Basic) RC500 I/O Toolkit Additional Option Choices 4 Latest full line of analog and discrete I/O 10/100BaseTx (auto-detecting) 1500 Volts RMS 1 minute Up to 38400 baud Modbus RC500 I/O Toolkit Windows XP Dell Workstation (minimum 32MB RAM and 100MB HDD space) Configuration, calibration, diagnostics, and limited exporting of I/O definitions. - Full importing and exporting of I/O definitions, peer to peer I/O transfers, and the IOmap shared database. - Datalogging capability For More Information To learn more about the RC500 RTU, visit www.honeywell.com/ps or contact your Honeywell account manager. Automation & Control Solutions Process Solutions Honeywell 1860 W. Rose Garden Lane Phoenix, AZ 85027 Tel: 800-822-7673 www.honeywell.com/ps PN-09-30-ENG October 2009 © 2009 Honeywell International Inc.