Transcript
TEST NUMBER - 239-12R2 REPORT OF TESTING TO AS/ACIF S031:2001 Australian Standard Requirements for ISDN Basic Access Interface for Sangoma Technologies 100 Renfrew Drive, Suite 100 Markham ON L3R 9R6 Canada (905) 474 1990 of ISDN BRI Interface B500xx on August 29, 2012 Tested by:
Mark R. McSweeney
Reviewed by:
This report may not be reproduced except in full without written permission from Compliance Worldwide, Inc.
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 1 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx Table of Contents 1
Scope ......................................................................................................................................................4
2
Test parameters ......................................................................................................................................4
2.1
Laboratory environment ..........................................................................................................................4
3
Description of customer equipment.........................................................................................................5
4
Test program ...........................................................................................................................................6
4.1 5
Requirements matrix ...............................................................................................................................6 Test Results ............................................................................................................................................7
5.1
General....................................................................................................................................................7
5.1.1
Fail safe operation...................................................................................................................................7
5.1.2
Emergency services access....................................................................................................................7
5.1.2.1 5.2
General....................................................................................................................................................7 Physical layer (Layer 1)...........................................................................................................................8
5.2.1
General....................................................................................................................................................8
5.2.2
Variations or additions.............................................................................................................................8
5.2.2.1
Terminating resistors...............................................................................................................................8
5.2.2.2
ITAAB advisory notes..............................................................................................................................8
5.3
Data link layer (Layer 2) ..........................................................................................................................9
5.3.1
General....................................................................................................................................................9
5.3.2
ITAAB advisory notes..............................................................................................................................9
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 2 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx 5.4 5.4.1
General- ..................................................................................................................................................9
5.4.2
Variations/additional requirements..........................................................................................................9
5.4.2.1
Malicious call identification (MCID) .........................................................................................................9
5.4.2.2
Calling line identification restriction (CLIR) ...........................................................................................10
5.4.2.3
Calling line identification presentation (CLIP) .......................................................................................10
5.4.2.4
ITAAB advisory notes............................................................................................................................10
5.4.2.5
Initiation of automatic repeated outgoing call attempts.........................................................................10
5.5 6
Network layer (Layer 3) ...........................................................................................................................9
CE intended for connection to an AUSTEL TS 013 based ISDN BA Interface ....................................10 Photographs ..........................................................................................................................................11
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 3 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx 1
Scope S031 specifies the technical conditions and performance requirements for Customer Equipment (CE) at the Physical, Data Link and Network Layers (Layers 1, 2 and 3) when connected to an Integrated Services Digital Network (ISDN) Basic Access interface at the S/T reference point. Note: This report has been compiled to document ISDN BRI Interface B500xx ISDN interface using Primary Rate Access testing results in comparison to the requirements as specified in S031. All results are based on a test of one sample, only in as much as that sample represents other production units. If any significant changes are made to the unit, the changes shall be evaluated and a retest maybe required.
2
Test parameters
2.1
Laboratory environment All tests were carried out under the following conditions: Ambient Temperature:
15 - 25
°C
Relative Humidity:
30 - 75
%
Air pressure:
86 – 106
kPa
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 4 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx 3
Description of customer equipment Trade Name:
Sangoma B500
Model Number:
B500xx
Serial Number:
n/a
Input Power:
3.3, 5 VDC via host chassis
Description:
The ISDN BRI Interface B500xx 4 port ISDN BRI interaface. The device supports both Point-to-Point (PTP) and Point-to-Multi-Point configuration and was tested in both configurations. The B500xx is sold under 4 model numbers: B500 B500D B500E B500DE
PCI card without echo canceller daughter card PCI card with echo canceller daughter card PCI express card without echo canceller daughter card PCI express card with echo canceller daughter card
The model evaluated for this test report was the B500D
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 5 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx 4
Test program
4.1
Requirements matrix
Status Key C Complies with requirement D Does not Comply with requirement I Informative O Outside scope of this report NA Not Applicable S031 Reference
239-12 Reference
Description
Status
Notes
5.1
5.1
General
I
5.1.1
5.1.1
Fail-Safe operation
O
5.1.2
5.1.2
Emergency Services Access
C
5.2
5.2
Physical Layer 1 requirements
I
5.2.1
5.2.1
General
C
5.2.2
5.2.2
Variations or additions
C
5.2.2.1
5.2.2.1
Terminating resistors
C
5.2.2.2
5.2.2.2
ITAAB Advisory Note
C
5.3
5.3
Data Link Layer (Layer 2)
I
5.3.1
5.3.1
General
C
5.3.2
5.3.2
ITAAB Advisory Note
C
5.4
5.4
Network Layer (Layer 3)
I
5.4.1
5.4.1
General
C
5.4.2
5.4.2
Variations/additional requirements
C
5.4.2.1
5.4.2.1
Malicious Call Identification (MCID)
NA
1
5.4.2.2
5.4.2.2
Calling Line Identification Restriction (CLIR)
NA
2
5.4.2.3
5.4.2.3
Calling Line Identification Presentation (CLIP)
C
5.4.2.4
5.4.2.4
ITAAB Advisory Note
C
5.4.2.5
5.4.2.5
Initiation of automatic repeated outgoing call attempts
NA
3
Notes 1. CE does not support MCID 2. CE does not support CLIR 3. CE does not support automatic repeated outgoing call attempts Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 6 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx 5
Test Results
5.1
General
5.1.1
Fail safe operation Data: This report addresses only the ISDN BRI interface performance aspects in regards to S038 and hence fail-safe operation requirements are outside the scope of this report. Notes:
None
5.1.2
Emergency services access
5.1.2.1
General Data: Requirement
Status YES/NO
CE with dialling capability shall support dialling ‘000’
YES
CE with handset and dialling capability shall support dialling of ‘000’ and ‘106’
YES
Notes:
Limit YES
None
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 7 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx 5.2
Physical layer (Layer 1)
5.2.1
General Data: OK Notes:
CE complies with CTR003, Amendment 1 Layer 1 requirements as documented in Compliance Worldwide report 238-12 None
5.2.2
Variations or additions
5.2.2.1
Terminating resistors Data: OK
The CE allows for disconnection/reconnection of the terminating resistors for CE intended to work in a point-to-point wiring configuration
OK
The CE allows for disconnection/reconnection of the terminating resistors for CE intended to work in a point-to-point wiring configuration
Notes:
5.2.2.2
None
ITAAB advisory notes Data: OK Notes:
CE complies with ITAAB advisory note 071, 096, 102, 116 and 126 with regards to Layer 1 requirements as documented in Compliance Worldwide report 238-12 None
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 8 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx 5.3
Data link layer (Layer 2)
5.3.1
General Data: CE complies with CTR003, Amendment 1 Layer 2 requirements as documented in Compliance Worldwide report 238-12
OK Notes:
5.3.2
None
ITAAB advisory notes Data: CE complies with ITAAB advisory note 072 with regards to Layer 2 requirements as documented in Compliance Worldwide report 238-12
OK Notes:
None
5.4
Network layer (Layer 3)
5.4.1
GeneralData: OK Notes:
CE complies with CTR003, Amendment 1 Layer 3 requirements as documented in Compliance Worldwide report 238-12 None
5.4.2
Variations/additional requirements
5.4.2.1
Malicious call identification (MCID) Data: CE does not support MCID Notes:
None
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 9 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx 5.4.2.2
Calling line identification restriction (CLIR) Data: CE does not support CLIR Notes:
5.4.2.3
None
Calling line identification presentation (CLIP) Data: OK Notes:
5.4.2.4
CE complies with EN 300 089 and EN 300 092-1 by meeting CTR 4 layer 3 requirements documented in Compliance Worldwide report 238-12 None
ITAAB advisory notes Data: OK Notes:
5.4.2.5
CE complies with ITAAB advisory note 055, 071, 087 and 096 with regards to Layer 3 requirements as documented in Compliance Worldwide report 238-12 None
Initiation of automatic repeated outgoing call attempts Data: CE does not support automatic repeated outgoing call attempts Notes:
5.5
None
CE intended for connection to an AUSTEL TS 013 based ISDN BA Interface Data: CE is not intended for connection to a TS 013 based ISDN BA interface Notes:
None
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 10 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx 6
Photographs
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 11 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 12 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 13 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 14 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 15 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 16 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 17 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 18 of 19
TEST NUMBER: 239-12R2 MANUFACTURER: Sangoma Technologies EUT: ISDN BRI Interface B500xx
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873 (603) 887 3903 Fax 887 6445 http://www.complianceworldwide.com 239-12R2 Sangoma Technologies ISDN BRI Interface B500xx
Page 19 of 19