EMC TEST REPORT METEL s.r.o., Žižkův Kopec 617, 55203 Česká Skalice xDW-S-PDS-BOX/12 Measured Date Type Version DPS SN Tomáš Metelka 28th May 2016 xDW-S-PDS-BOX/12 RDW-PDS_08012016 / 1 20160422017 -1- Immunity Testing - Electrostatic Contact Discharge Test No. 1: EN61000-4-2 ed.2 Device Used: SRG200LC Description of Connection: The EUT "RDW-S-PDS" and reference counterpart TDW-S-PDS were connected with 1m long SM fiber. The EUT was supplied separately from a 12VDC battery. The other devices (Control Panel EVO, Keyboard, TDW-S-PDS) were supplied separately from different a 12VDC battery. The other devices protected OVP-PDS protection. The test was used to demonstrate, resistance to electrostatic discharge. Scheme: CP EVO → OVP-PDS → twist cable 70m → RDW-S-PDS → 1m SM fiber → TDW-S-PDS → Keyboard Universal Connection Scheme: Results: Level Of Test kV Result Comment 2 4 (-)b / (+)b 5x negative pulses / 5x positive pulses 3 6 - 4 8 (-)b / (+)b 5x negative pulses / 5x positive pulses Measured Date Type Version DPS SN Tomáš Metelka 28th May 2016 xDW-S-PDS-BOX/12 RDW-PDS_08012016 / 1 20160422017 -2- Immunity Testing - Electrostatic Air Discharge Test No. 2: EN61000-4-2 ed.2 Device Used: SRG200LC Description of Connection: The EUT "RDW-S-PDS" were involved similarly to resistance tests - Electrostatic contact discharge (Test No. 1). The test demonstrated the resistance to electrostatic discharge. Results: Level Of Test kV Result Comment 2 4 (-)a / (+)b 5x negative pulses / 5x positive pulses – 1x AutoReset 3 8 - 4 15 (-)b / (+)b 5x negative pulses / 5x positive pulses Immunity Testing – Electrical Fast Transient / Burst Test No. 3: EN61000-4-4 ed.3 Device Used: Generator RG451, Capacitive Coupling Clamp KK 401 Description connection: The EUT "RDW-S-PDS" using the same connection scheme as the test "EN61000-4-2" only for application BURST with coupling clamp on BUS port we using a 2m length twist cable. For the application interference BURST we used capacitive coupling clamp connected to the coaxial HV output on BURST tester. Using procedure BURST No. 1. The length of each test was 60 seconds. Measured Date Type Version DPS SN Tomáš Metelka 28th May 2016 xDW-S-PDS-BOX/12 RDW-PDS_08012016 / 1 20160422017 -3- Scheme: AUX EQUIP. Electrical Fast Transient / Burst EUT line line Coupling Clamp 0,1 m 0,1 m insulating support insulating support Ground reference plane (GRP) GND Generator → BURST Grounding connection according to the manufacturer´s specifications Results: BURST on PORT 1 Level Of Test kV / KHz Result Comment 2 1 / 5KHz (-)a / (+)a (-)/(+) length 60sec 3 2 / 5KHz - 4 4 / 5KHz (-)a / (+)a (-)/(+) length 60sec Immunity Testing – Surge Pulse Test No. 4: EN61000-4-5 ed.2 Device Used: Generator RG451 Description of Connection: The EUT "RDW-S-PDS" using the same connection scheme as the test "EN61000-4-2 (Test No. 1)". For surge pulse application (SURGE No. 1) with output impedance 42 Ohms we using modified twist cable connected to the generator (twist cable with brought-out twist coule for connection to the generátor). Test (DATA) x (PE) / (CLK) x (PE) / (+V) x (PE). (PE=GND). After surge impulse we controlled the functioning EUT connecting the control panel EVO. (SURGE No. 1: level 2 → procedure 11 – 20) Measured Date Type Version DPS SN Tomáš Metelka 28th May 2016 xDW-S-PDS-BOX/12 RDW-PDS_08012016 / 1 20160422017 -4- Scheme: Generator combined wave Ancillary Equipment Protection Equipment Separation Network Reference Ground Results: Wire (DATA) - (PE) Level of Test kV Result Comment 2 1 (-)b / (+)b 5x negative pulses / 5x positive pulses (period 6sec) Wire (CLK) - (PE) Level of Test kV Result Comment 2 1 (-)b / (+)b 5x negative pulses / 5x positive pulses (period 6sec) Wire (+V) - (PE) Level of Test kV Result Comment 2 1 (-)b / (+)b 5x negative pulses / 5x positive pulses (period 6sec) Measured Date Type Version DPS SN Tomáš Metelka 28th May 2016 xDW-S-PDS-BOX/12 RDW-PDS_08012016 / 1 20160422017 -5- Immunity Testing – Static Magnetic Field 50 Hz Test No. 5: EN61000-4-8 ed.2 Device Used: Autotransformer 2,3kW / Conversion transformer 2KVA, Ring coil 20mH/1m; 2x Tripod for mounting coil; insulation pad Description of Connection: The EUT "RDW-S-PDS" was exposed a static magnetic field. The EUT using the same connection scheme as the test "EN61000-4-2" only to ensure the remoteness of the test device from the neighborhood we using longer twist cable and longer SM optical fiber. The equipment tested was separately powered from a 12VDC battery. We gradually changed position the EUT to the reference surface (0° / 45° / 90°) during the test. The length of each test was 60 seconds. During the test we controlled the functioning of the EUT. Scheme: ATR L ITR EUT N A PE Results: Level Of Test A/m Result Comment 2 3 - 3 10 (-)a / (+)a 4 30 - 5 100 (-)a / (+)a length 60sec (0°/45°/90°) length 60sec (0°/45°/90°) Measured Date Type Version DPS SN Tomáš Metelka 28th May 2016 xDW-S-PDS-BOX/12 RDW-PDS_08012016 / 1 20160422017 -6- Immunity Testing – Pulse Magnetic Field Test No. 6: EN61000-4-9 Device Used: Generator RG451 output COIL; Square coil 0,6m x 0,6m; insulation pad; tripod for mounting coil Description of Connection: The EUT "RDW-S-PDS" was exposed to pulsed magnetic field. The EUT using the same connection scheme as the test "EN61000-4-2 (Test No. 1)" only to ensure the remoteness of the test device from the neighborhood we using longer twist cables and longer SM optical fiber. We gradually changed position the EUT to the reference surface (0° / 45° / 90°) during the test. During the test we controlled the functioning of the EUT. Chosen procedure SRG1 No10. Scheme: EUT Generator Twisted cable length maximum 2 m (GRP) GND Separate source Results: Level Of Test A/m Result Comment 3 100 (-)a / (+)a 5x negative pulses / 5x positive pulses (period 1sec)(0°/45°/90°) 4 300 - 5 1000 (-)a / (+)a 5x negative pulses / 5x positive pulses (period 6sec)(0°/45°/90°) Measured Date Type Version DPS SN Tomáš Metelka 28th May 2016 xDW-S-PDS-BOX/12 RDW-PDS_08012016 / 1 20160422017 -7-