Transcript
Datasheet for TESTEC BNC-Test lead according MIL-Standard / RoHS compliant Cable Type Impedance max. Frequency Conductor AWG Conductor Size Insulation Braid Copper Jacket Capacity max. Insulation Voltage Working Voltage Attenuation @ 20°C
Insulation Resistance Standard
Connector RG58 C/U 50Ohm 1GHz 20AWG - Tinned Copper 19 / 0,18mm ± 0,008mm PE, D 2,95mm ± 0,05mm Tinned Copper PVC D 5,00mm ± 0,15mm 105pF/m 2000V max. 500V 0,66dB / 10m @ 10MHz 1,65dB / 10m @ 100MHz 2,38dB / 10m @ 200MHz 3,56dB / 10m @ 400MHz 5,60dB / 10m @ 1000MHz 10MOhm / km bei 20°C MIL-C17F
Type Impedance max. Frequency Center Pin Dielectric Body / Shell Insulation Resistance Working Voltage Test Voltage Insertions / Extractions Contact Resistance VSWR
BNC 50Ohm 0-1,5GHz Brass with Gold Plating 3-5u" min Teflon Brass, Nickel Plated 5000MOhm max. 500V 1500V 500 1,5 Milliohm Center Contact 1,0 Milliohm Outer Contact < 1,10 (1GHz, 50W)
Standard
MIL-C-39012
TESTEC Elektronik GmbH - Westerbachstr. 58 - 60489 Frankfurt/Germany - Tel.: +49 (0)69-943335-0 - www.testec.de