The Aether Installation And User Manual

   EMBED


Share

Transcript

THE AETHER INSTALLATION AND USER MANUAL AURORA WOODFIRES INSTALLATION AND USER MANUAL +612 66874880 PO 347 BOX BYRON BAY NSW 2481 CONTENTS PLANNING ! ! ! ! ! ! ! 1 DIMENSIONS & SPECIFICATIONS INSTALLATION 3 USING THE AETHER TESTING 2 4 5 KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266 874880 PO 347 BOX BYRON BAY NSW 2481 1. PLANNING ! We would like to thank you for your purchase of The Aether.The care and craftsmanship we put into each fire will give you trouble free heating for many years to come. For your safety, ensure you have read the operation guidelines prior to use. The Aether should be installed by a qualified professional. Contact us for help finding an installer in your area. ! Installation Process: – Choose the position of firebox and flue ensuring that you follow the clearances described within this section – Install the suspension bracket – Install the external flue – Install the internal flue and engage the firebox – Ensure the floor has adequate protection ! CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, AURORA WOODFIRES SHOULD BE CONSULTED IN THE FIRST INSTANCE. ! !WARNING: ! ! ! • THE APPLIANCE AND FLUE-SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. • APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING ‘TESTED TO AS/NZS 4013’. • ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013. AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266 874880 PO 347 BOX BYRON BAY NSW 2481 1. PLANNING CONTINUED Wall MINIMUM CLEARANCE – INTERNAL !Clearance Distance Wall ! Clearance Distance WALL MATERIAL POSTION OF FIREBOX CLEARANCE DISTANCE Non combustible Fixed 100mm Non combustible Rotating 100mm Combustible Fixed 700mm Combustible Rotating 1200mm A combustible surface is anything that can burn (i.e. plaster, wall paper, wood, fabrics etc.)These surfaces are not limited to those that are visible and also include materials that are behind non-combustible material. Timber frames behind gyprock are considered combustible. ! IMPORTANT: Frames must also be considered. Timber window frames must be treated as combustible surfaces. Aluminium frames can be treated as noncombustible surfaces AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266 874880 PO 347 BOX BYRON BAY NSW 2481 2. DIMENSIONS & SPECIFICATIONS WEIGHT & DIMENSIONS Firebox diameter 900mm Firebox weight 55kg Flue diameter 165mm Flue weight 12kg/meter Standard bracket weight 23kg External flue kit Triple skin 152/203/254 mm ! THE AETHER • Stainless steel ball bearing 360 degree rotation system • Flue custom length with damper • Material: 4mm Steel • Finish: high temperature coating ! ! ! ! system. Resistant to 650 degrees MATTE BLACK A range of other colours are available on request. For more information visit our website: www.aurorawoodfires.com.au AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266 874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION FLAT ROOF INSTALLATION 3.1 Installing the suspension bracket ! • The bracket must be structurally secured within the roof as shown in the diagram • The largest cylinder must project down from the ceiling by at least 150mm (BCA requirement) unless the ceiling is made ! from a non-combustible material such as concrete. • You must leave a 25mm clearance gap between the bracket and the ceiling. This gap will be covered by the ceiling Flange. ! ! ! • 12mm ventilation gap between the plasterboard and the ceiling flange • 25mm minimum clearance from the triple skin flue to any combustible material within the roof space • 50mm minimum overlap of the stainless steel 6” flue into the connector ! AURORA WOODFIRES INSTALLATION AND USER MANUAL • Engage smallest diameter of the triple skinned flue, minimum 50mm into the connector in the lower active flue. +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) PITCHED ROOF INSTALLATION (Custom Made Bracket) AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) PITCHED ROOF INSTALLATION 3.2 Installing the external flue ! The top of the flue must be 60cm higher than the highest point of the roof. Alternatively, there must be a ! minimum distance of 5 meters from any higher section of roof. 1. The connection piece is welded into the top of the active lower flue. The upper triple skinned flue will slot into it. 2. Ensure the triple skin flue is installed as per Australian standards (see diagrams below). 60cm 60cm 5 m 1 meter The minimum height of the flue system further than 5 meters from the highest point of the roof shall be 1 meter above roof penetration. AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) FLAT ROOF INSTALLATION (LESS THAN 5% PITCH) The top of the flue must be 60cm above the roofline. Alternatively, there must be a minimum distance of 5 meters from any higher section of roof. 60cm 5m 60cm The minimum height of the flue system further than 5 meters from the highest point of the roof shall be 1 meter above roof penetration. 1 meter AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) FLAT ROOF INSTALLATION 3.3 Assembling the external flue IMPORTANT • CRIMPS (MALE ENDS) ON STAINLESS STEEL PIPES TO POINT DOWN INTO THE HEATER IMPORTANT • CRIMPS (MALE ENDS) ON OUTER PIPES TO POINT UPWARDS ! • POP RIVET ALL JOINTS WITH 1/8 “ MONEL RIVETS AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) PITCHED ROOF INSTALLATION 3.3 Assembling the external flue IMPORTANT • CRIMPS (MALE ENDS) ON STAINLESS STEEL PIPES TO POINT DOWN INTO THE HEATER IMPORTANT • CRIMPS (MALE ENDS) ON OUTER PIPES TO POINT UPWARDS ! • POP RIVET ALL JOINTS WITH 1/8 “ MONEL RIVETS AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) 3.4 Installing the internal flue Position the single skin flue inside the suspension bracket and tighten the grub screws. Use a level to ensure that the flue is perfectly vertical and the grub screws are tight. Grub Screws AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) 3.5 Engaging The Firebox ! Assemble the shaft & bearing system in the following order: ! 1. Push the thrust bearing over the shaft. 2. Engage the firebox. If firebox is to be locked insert locking plates before engaging. 3. Push the second bearing over the shaft. 4. Push the bearing cap over the second bearing. 5. Tighten the first 16mm nut. If necessary back the nut off slightly until the firebox rotates freely. 6. Tighten the second 16mm nut against the first. 7. Insert the split pin. IMPORTANT Ensure the threaded shaft DOES NOT KNOCK against the firebox when engaging. ! THIS CAN DAMAGE THE THREAD. ! The firebox MUST BE LIFTED PARALLEL when engaging. Item NO. NOTE: The bearings are shipped in the correct order on the shaft. AURORA WOODFIRES INSTALLATION AND USER MANUAL PART NUMBER QTY 1 Pivot-Upper Plate 1 2 Ball Bearing Shaft 1 3 Pivot Lower plate 1 4 Stainless Thrust Bearing 2 5 Ball Bearing Cap 1 6 16mm Nut 2 +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) Locking Plates AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) 3.5 Floor protection ! • You will require a hearth to protect any combustible floor beneath the firebox. Your floor protection must extend 30cm beyond the diameter of the firebox in all directions. ! • If installed directly on combustible material, the floor protector must be made of a 30mm thick sheet of material with a thermal conductivity of a 0.21W/m.K. Non-combustible finishes can be applied to the floor protector (tiles, steel sheet, light concrete, etc). ! • If the combustible floor is installed on concrete, you can replace the combustible material with a non-combustible material laid directly onto the concrete. ! ! AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266874880 PO 347 BOX BYRON BAY NSW 2481 3. INSTALLATION (CONTINUED) FLOOR PROTECTOR LOCATION FLOOR PROTECTOR DETAILS Floor protector laid directly onto timber floor 30mm thick material with thermal conductivity of 0.21w/m.k. Floor protector laid directly onto timber joist as above Floor protector laid directly onto concrete, with combustible floor surrounding it as above Note: Non combustible finishes can be applied to the floor protector, e.g. tiles, stone, metal. Floor protector 30cm 650mm combustible 500mm Non combustible Floor AURORA WOODFIRES INSTALLATION AND USER MANUAL 30cm 0422417295 PO 347 BOX BYRON BAY NSW 2481 4. USING THE AETHER ! 4.1 What you should burn • Maximum load capacity: No more than four large logs (not exceeding 110mm in diameter) at a time. • Untreated, air dried hardwood • Split logs with a humidity content of less than 20% 4.2 Do not burn • Trash • Painted plastic • Coated or preservative treated wood • Waste or black coal • Inflammable liquids • Fire gels ! ! • Moist wood with a residual humidity content of more than 20% (this may cause soothing of the chimney). IMPORTANT: • Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee. • Burning only seasoned hardwood helps to protect the environment and lower emissions. WARNING: • DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE. • DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING. • DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES. CAUTION: • THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS. • THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE HAZARDOUS. ! • DO NOT TOUCH THE FIREBOX OR FLUE WHEN HOT. AURORA WOODFIRES INSTALLATION AND USER MANUAL 0422417295 PO 347 BOX BYRON BAY NSW 2481 4. USING THE AETHER ! IMPORTANT FOR YOUR SAFETY & THE LONGEVITY OF YOUR FIRE 4.3 High Temperature Stove Paint Initial Firing Process ! Your stove has been painted with the highest quality coating used in the heating appliance industry. We have selected Stove Bright® brand coatings because the product has been proven durable, colourfast, and beautiful at temperatures to 1200°F. Stove Bright® high temperature paint has been air dried creating a quality coating. To optimise the performance of the coating, and to maximise its durability, it needs to go through a heating process. This process is explained on the next page and should be followed as closely as possible during the first burn of your new suspended fireplace. Once this initial firing process is successfully completed, the coating will bond to the metal with a colourfast finish that will last for years ! ! ! AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266 874880 PO 347 BOX BYRON BAY NSW 2481 4. USING THE AETHER 4.3 High Temperature Stove Paint Initial Firing Process - continued ! Do the following BEFORE you fire the stove for the first time: 1. Ventilate: Open doors and windows in the room with the stove. To speed dissipation of odour from the initial firing process, you can place a fan in the room to move the air. 2. Vacate: The fumes from the initial heating process are non-toxic, but may be uncomfortable for babies, small children, pregnant women, elderly, pets, or anyone with breathing difficulties. ! INITIAL FIRING PROCESS ! 1. Slowly bring the stove to a medium burn, about 205°C, for about 45 minutes. ! 2. Increase the burn temperature to a hot burn, about 315°C, for an additional 45-60 minutes. ! ! ! NOTE: During the initial firing process there are changes in the paint causing it to give off an odour and some visible smoke. The fumes are non-toxic, but can be unpleasant. Ventilate and vacate the room to avoid discomfort. Once the burn is complete there will be no odour or smoke the next time the stove is fired. AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266 874880 PO 347 BOX BYRON BAY NSW 2481 5. TESTING ! TESTING LABORATORY: Vipac Engineers & Scientists ! MANUFACTURER: Aurora Wood Fires Pty Ltd ! MODEL: The Aether ! TEST REPORT NUMBER: 30A-14-0097-TRP-359162-0 ! TEST DATES: 25 January 2015 to 30 January 2014 ! CONCLUSION: This appliance meets the requirements of AS/NZS 4013:2014 section 1.2.3 (f) ! TEST REPORT NUMBER: 30A-14-0097-TRP-358755-0 ! TEST DATES: 12 January 2015 to 26 January 2014 ! CONCLUSION: This appliance complies with the requirements of AS/NZS 2918:2001 Appendix B for the configurations tested. ! AURORA WOODFIRES INSTALLATION AND USER MANUAL +61 266 874880 PO 347 BOX BYRON BAY NSW 2481