Preview only show first 10 pages with watermark. For full document please download

The Datasheetarchive - Datasheet Search Engine

   EMBED


Share

Transcript

Catalog 1307191 Revised 10-00 R F C O A X I A L S O L U T I O N S F O R WIRELESS BASE STATION The new Tyco Electronics RF Coaxial Solutions for Communications Equipment catalog combines the best products from industry leading brand names like Omni SPECTRA, M/A-COM, Siemens E.C., GreenPar, and of course AMP. We have integrated these into one cohesive set of RF products focused specifically on wireless, wireline carrier, and enterprise networking sectors of the world telecom equipment market. Tyco’s broadest selection of RF connectors and coaxial cable assemblies provides you with a solution for every interconnection requirement. Type N and 7/16 connectors are used where high power and rugged reliability are required, typically as antenna feeds, filter/combiner I/O’s, and power amplifier outputs. SMA, SMB, and TNC connectors are the primary cable interface for inner cabinet routing and are available in panel mount, board mount, and cable terminations. Subminiature connectors such as MCX, OSMP, DIN, and BlindMate provide panel to board and backplane connections. Finally, our micro miniature OSMT, SSMT, and MMCX series provide excellent board to board and card edge to board solutions. All of these interfaces are supported with cable terminating tools and between series adapters to meet all your requirements for trouble free terminations at the lowest applied cost. The appendices hold a wealth of information including a Theory and Application tutorial, RG/U cable specification tables, Application notes on White Bronze plating and intermodulation distortion. Whether you need rugged external RF power cables, panel mount, board to board, blind mate, or DIN, Tyco Electronics has the connection. RF COAXIAL SOLUTIONS FOR COMMUNICATIONS EQUIPMENT Based on the communications gear that you are designing: CARRIER RACK EQUIPMENT Wireless Basestations Carrier Rack Equipment Chassis Set Top Box NIC Card Typical equipment drawings guide you to the interconnect section(s) in this catalog. Selection guides will direct you to products based on performance and mechanical requirements such as impedance, VSWR, max. frequency, power handling, etc. CHASSIS There are other guides to help you find the right connection: A table of contents listed by interface type, a complete connector type selector describes each interface with typical applications, and a mini-selection guide shows key parameters to quickly pinpoint the right connector type. SET TOP BOX NIC CARD I WIRELESS BASE STATION SMA CONNECTORS PAGE 99 Radio base station cabinets demand packaging that combines high power r.f. signals, high speed digital data, and analog signals. Cabinet input/output connections are provided by N Series and 7/16 connectors. Plug-in r.f. modules require Blind Mate, DIN inserts, and panel mount connectors. Transceiver modules utilize MCX, OSMT, and SSMT board and cable connectors for board to board and panel to board applications. Finally, both semi-rigid and flexible RG cable assemblies route signals throughout the entire cabinet. SMB CONNECTORS PAGE 177 N SERIES CONNECTORS, PAGE 17 TNC CONNECTORS, PAGE 23 II 7-16 SERIES CONNECTORS, PAGE 1 LIGHTNING PROTECTION CONNECTORS, PAGE 9 7-16 SERIES CABLE ASSEMBLIES, PAGE 269 N SERIES CABLE ASSEMBLIES, PAGE 269 MCX CONNECTORS, PAGE 197 OSMT CONNECTORS, PAGE 223 SSMT CONNECTORS, PAGE 215 OSMP SUBMINIATURE BLIND MATE CONNECTORS, PAGE 172 DIN INSERTS, PAGE 237 COAXICON COAXIAL CONTACTS, PAGE 247 SIEMAX CONNECTORS, PAGE 253 III CARRIER RACK EQUIPMENT For today’s fast paced Carrier Equipment market, Tyco Electronics offers a broad line of RF interconnect products that meet demanding customer requirements for CATV, telecom and data transmission applications. Connectors, cable assemblies, and applicator tooling are available for applications ranging from central office to customer premise environments, 50 or 75 ohms, from rack based equipment to set top boxes. Styles range from standard miniature RF connectors such as F series, BNC and TNC to subminiature RF connectors such as SMA, SMB, SMC and Blind Mate connectors, to Micro miniature MMCX, OSMT and SMT Quick Grip products. Siemax connectors provide multi-positional surface mount technology RF connection for pcb and panel applications, and offer superior packaging density. Between Series adapters are available, along with connectors meeting international DIN and IEC standard interfaces. High performance GHz range BNC connectors meet the needs for faster signaling. G SERIES CONNECTORS, PAGE 97 F SERIES CONNECTORS, PAGE 91 IV BNC CONNECTORS, PAGE 41 SMA CONNECTORS, PAGE 99 SMB CONNECTORS, PAGE 177 TNC CONNECTORS, PAGE 23 DIN INSERTS, PAGE 237 SIEMAX CONNECTORS, PAGE 253 MMCX CONNECTORS, PAGE 233 V CHASSIS, NIC CARD AND SET TOP BOX Coaxial interconnects have evolved in the enterprise market place over the years. The BNC interfaces that once dominated the Ethernet premise installations to coax products that provide high speed access to the carrier infrastructure. In today’s environment, Network Interface Cards (NIC) still feature Capacitively Decoupled BNC connectors with built-in chip capacitors to reduce noise and ground loop currents. For the infrastructure, the standard coaxial interfaces to the infrastructure include both 50 and 75 ohm BNC connectors. The BNC family features numerous styles including cable plugs and jacks, adapters and printed circuit board connectors. To address manufacturability, we offer the board mount in SMT, wave solder, and press fit. More recently, the SMB interface is the one of choice for improved density and is available in both commercial and MIL-type. Again, our portfolio has a wide variety of configurations to address your system requirements. Lastly, as broadband CATV becomes more prevalent for internet access in cable modems, our family of F connectors offer a high performance solution. VI SET TOP BOX CHASSIS BNC CONNECTORS, PAGE 41 SMB CONNECTORS, PAGE 177 F CONNECTORS, PAGE 91 DECOUPLED BNC, PAGE 79 NIC CARD VII Product Facts ■ ■ Listed under the Component Program of Underwriters Laboratories Inc., File No. E-81956 as indicated by Product Family R R ■ Recognized under the Component Program of Underwriters Laboratories Inc., File No. E-81956 as indicated by Product Family R Certified by Canadian Standards Association File No. LR 7189 as indicated by Product Family ■ Produced under a Quality Management System certified to ISO 9001 A copy of the certificate is available upon request ISO900e1d i rtif Ce Need more information? Call the Technical Support Center: 1-800-522-6752. The Technical Support Center is staffed with specialists well versed in all AMP products. The Center can provide you with: ■ Technical Support ■ Catalogs ■ Technical Documents ■ Product Samples ■ AMP Authorized Distributor Locations ■ Tooling Assistance Instant Information by the AMP FAX Service 24 hours a day... Call the Technical Support Center at 1-800-522-6752 any time. Choose the new AMP FAX service option at the voice prompt. The Information you request will be faxed to you within a few minutes. From the AMP FAX service you can get: ■ Drawings ■ Instruction Sheets ■ Product Specifications ■ Latest Revisions of Catalog Pages. ■ The list of your closest distributors. ■ Instructions on how to use the AMP FAX service. Visit our website at: www.amp.com/communications/com Dimensioning: Dimensions are in millimeters over inches. Metric symbols used are: C (Celsius) N (Newton) m (meter) mm (millimeter) mm2 (square millimeter) kg (kilogram) © Copyright 1982, 1990, 1992, 1994,1998, and 2000 by Tyco Electronics Corporation. All Rights Reserved. AMP, AMP-FAX, AMP-O-LECTRIC, AMP-O-MATIC, AMPOMATOR, CERTI-CRIMP, COAXICON, PRO-CRIMPER and SMT QUICK-GRIP are trademarks. VIII AT&T and WESTERN ELECTRIC are trademarks of AT&T. BELDEN is a trademark of Belden Wire and Cable Company. BERK-TEK is a trademark of Berk-Tek, Incorporated. ROLM is a trademark of the Rolm Corp. TEFLON is a trademark of E.I. Dupont de Nemours and Company. Other products, logos, and company names mentioned herein may be trademarks of their respective owners. Catalog 1307191 Revised 10-00 RF Coax Connectors RF Catalog Table of Contents Miniature Connectors 7-16 Series Connectors ...................................................................................................1-8 Lightning Protection Connectors ...................................................................................9-16 Surge Protectors ........................................................................................................9-12 /4 Wave Stub Tuners ..............................................................................................13-16 N Series Connectors ....................................................................................................17-22 TNC Connectors ..........................................................................................................23-40 BNC Connectors ..........................................................................................................41-78 Decoupled Connectors................................................................................................79-86 Twin BNC Connectors .................................................................................................87-90 F Series and G Series Connectors ..............................................................................91-98 Subminiature Connectors SMA Connectors ........................................................................................................99-124 DIN Connectors .......................................................................................................125-148 Series 1.0/2.3 .......................................................................................................125-130 Series 1.6/5.6 .......................................................................................................131-141 OSMP Connectors ...................................................................................................149-154 Blind Mate Connectors ............................................................................................155-176 3.5 mm Blind Mate Connectors ...................................................................................156 2.8 mm Blind Mate Connectors............................................................................157-158 OSP Miniature Blind Mate Connectors.................................................................159-171 OSSP Subminiature Blind Mate Connectors ........................................................172-176 SMB Connectors ......................................................................................................177-196 MCX Connectors......................................................................................................197-206 Micro Miniature RF Coax Connectors SMT Quick Grip Connectors ....................................................................................207-214 SSMT Connectors ....................................................................................................215-222 OSMT Connectors ...................................................................................................223-232 MMCX Connectors...................................................................................................233-236 Multi Position Connectors DIN Inserts ...............................................................................................................237-243 Size 8 Contacts ........................................................................................................244-246 Coaxial Contacts (COAXICON) ...............................................................................247-252 Siemax Connectors..................................................................................................253-254 Between Series Adapters ............................................................................................255-264 Tooling ........................................................................................................................265-268 Cable Assembly Capabilities ......................................................................................269-272 Appendix A - Theory and Application ......................................................................................273-278 B - White Bronze Application Note ..........................................................................279-281 C - Intermodulation Application Note ......................................................................282-284 D - Typical Coaxial Cable Specifications ................................................................285-299 E - Maximum Power Handling Capabilities for Cables ...................................................300 F - Nominal Loss Characteristics for Cables ..................................................................301 G - Glossary of Terms ..............................................................................................302-306 Part Number Index ......................................................................................................307-313 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. IX Catalog 1307191 Revised 10-00 RF Coax Connectors Connector Selection Connector Types 7-16 Series connectors are designed for medium to high power applications such as cellular base stations, control components, antenna and broadcast. The 7-16 Series minimizes intermodulation distortion by silver plating the electrical path. Combined hex/knurl coupling nuts allow for manual or torque tightening, further reducing distortion by providing a strong butt joint. Lightning Protection devices have an integral surge arrestor capsule which is designed to protect equipment from high current pulses. It is effective against very fast rise times as induced by electromagnetic pulses from nuclear explosions (NEMP) and the slower pulses arising from lightning strikes (LEMP). N Series threaded connectors have an air dielectric interface and are low cost. These connectors operate to 11 GHz and are commonly used in cable-based local-area networks (LAN’s) medium power transmitters, and base station antenna applications. TNC connectors have an interface similar to BNC except for a threaded coupling nut. The tighter fit provided by this screw-on connection improves interface control allowing connectors to operate up to 11 GHz. TNC connectors are excellent for mobile units where top-notch performance is required under vibration. BNC connectors offer easy engagement and disengagement using bayonet couplings and overlapping dielectrics. They are most useful for frequently coupled and uncoupled RF connections with frequencies below 4 GHz. BNC connectors find applications in flexible networks, instrumentation, and computer peripheral interconnections. F & G Series connectors offer enhanced performance beyond 1 GHz. Designed to meet the rigorous requirements of Bellcore TA-NWT-001503 and SCTE specifications, the F & G series provides high current carrying capabilities in both sealed and un-sealed configurations. Plugs, jacks and adapters are available in threaded and push-on versions. These connectors meet the evolving needs of the communications industry for increased reliability and performance. SMA threaded connectors are widely used in microwave communications. Connectors operate to at least 12.4 GHz on flexible coax cables, and up to 26.5 GHz on semi-rigid coax cables. Crimp-on SMA connectors that operate to 26.5 GHz are available. Blind Mate connectors operate to 22 GHz for OSP, 26.5 GHz for 3.5 mm, 28 GHz for OSSP, and 40 GHz for 2.8 mm and OSMP styles. These connectors offer easy slide-on connection and require less alignment between the cable and the equipment than other connectors with comparable band width. Blind Mate connectors are widely used as coaxial interconnects between plug-in modules and motherboards when axial and radial misalignments are necessary. SMB connectors feature a snap coupling for fast connection. A self centering outer spring and overlapping dielectric allows easy snap-on and excellent performance even in moderate vibration. The SMB is smaller in size than the SMA and excellent where engineers are concerned about circuit miniaturization. Typical application is inter- or intra-board connection of RF or digital signals. Commercial 50 ohm versions operate to 4 GHz, and 75 ohm versions reach 2 GHz. MCX connectors offer a high reliability, space saving sub-miniature coaxial cable to cable and cable to board interconnection system. The MCX connectors impedance types are applicable up to 6 GHz. Surface Mount (SMT) connectors. The RF solution to the communication and information age. These connectors (OSMT,SSMT and SMT Quick Grip) are designed to meet the growing demand for surface mount RF connector technology. These connectors operate up to 6 GHz utilizing cable assembly design to terminate to SMT connectors. Surface mount connectors contribute to high density packaging and high volume manufacturing requirements. Multi Position connectors. These connector series, including the 1.0/2.3 (CECC 22230), 1.6/5.6 (CECC 22240), Subminiature D (DIN 41652 and CECC 75 301-082), and Tyco’s own Siemax multi coax connector series offer the customer a broad choice of options where density and performance are a major concern. The 1.0/2.3 series contacts are available in both 50 and 75 Ohm versions and are designed for use to 10 GHz. The different types of coupling mechanisms, such as screw on, slide-in and latching coupling provide for a variety of space-saving installations. The connector series 1.6/5.6 has been modified to incorporate improved technical advantages. A 75 Ohm design for use up to 8 GHz, it offers excellent screening effectiveness and is a most suitable component for those applications where the transmission of high bit rates is required. In Subminiature D type connectors these interfaces provide good electrical grounding and electromagnetic shielding in a small package size. These plug connectors address the increasing demands related to EMC (electromagnetic compatibility) and RFI (immunity to radiated noise), and are widely used as interface connectors in office and data systems, telecommunications equipment, and in measurement and control systems. Tyco’s Siemax connectors combine the benefits of surface mount technology and modular design. This 75 Ohm connector series operates up to 2 GHz and offers a compact grid pitch of 10mm. Its uses include multiplex and high-density systems, and Base Station applications. Miscellaneous connector types include multiple-circuit connectors that use coaxial contacts in a pin-and-socket configuration, crimp-on ferrules that offer fast, reliable connections for attaching one or more ground taps to shielded wire and braided shield terminations for connecting cable shields to pc boards. Also available are network/premises interconnect products for Ethernet/IEEE 802.3 systems and coaxial taps for simple, dependable connections from transceiver to LAN without cutting the cable. X Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Connector Selection Guide Nominal Impedance Ohms 50 50 Maximum Frequency GHz 7 2.5 Temperature Rating C -55° to +155° -45° to +85° 50 11 -65° to +85° 50 7 -65° to +165° 50 11 -65° to +165° 50 7 -55° to +85° 75 2 -55° to +85° 50 2.5 -65° to +165° 50 4 -65° to +165° 50 4 -55° to +85° 50 4 -55° to +85° 50 4 -65° to +165° 75 2 -65° to +85° Nonconstant — -55° to +85° F Series 75 — -55° to +85° G Series 75 — -55° to +85° SMA Semi-Rigid SMA Flexible 50 26.5 -65° to +105° 50 12.4 -65° to +165° OSMP 50 40 -65° to +165° Blind Mate 3.5 mm Blind Mate 2.8 mm OSP Semi-Rigid OSP Flexible OSSP Semi-Rigid OSSP Flexible 50 26.5 -65° to +105° 50 26.5 -65° to +105° SMB Product 7-16 Series Lightning Protection N Series Commercial TNC Single Crimp TNC Dual Crimp TNC Commercial TNC 75 Ohm BNC Single Crimp BNC Dual Crimp BNC Dual Crimp Commercial BNC Hex Crimp BNC Field Serviceable BNC 75 Ohm Twin BNC MCX Connectors 50 22 -65° to +125° 50 12.4 -65° to +125° 50 28 -65° to +125° 50 — -65° to +125° 50 4 -65° to +85° 50 6 -65° to +165° 75 6 -65° to +165° SMT Quick Grip SSMT OSMT 50 50 50 3 6 6 -40° to +125° -40° to +125° -40° to +105° MMCX 50 6 -55° to +155° Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Cable Retention lb RG8A/U — Adapter — 90 400.3 (RG-214/U) 60 266.9 (RG-58C/U) 60 266.9 (RG-58C/U) 60 266.9 (RG-58C/U) 60 266.9 (RG-59B/U) 60 266.9 (RG-58C/U) 60 266.9 (RG-58C/U) 60 266.9 (RG-58C/U) 60 266.9 (RG-58C/U) 40 177.9 (RG-142B/U) 60 266.9 (RG-59B/U) 25 111.2 (RG-108/U) 40 (Series 59, 6, 7 — Single Braid) 40 (Series 59, 6, 7 — Single Braid) 60 266.9 (RG-402/U) 40 177.9 (RG-58C/U) 20 89 (RG-405/U) 60 266.9 (RG-402/U) 30 133.4 (RG-405/U) 60 267.02 (RG-402/U) 40 178 (RG-58/U) 20 89 (RG-405/U) 20 89 (RG-316/U) 20 89 (RG-316/U) 20 32 (RG-316/U) 20 32 (RG-187/U) Omni-Flex — Omni-Flex — Omni-Flex — 10 44.5 (RG-178/U) Dimensions are in millimeters over [inches] Durability Cycles Threaded Threaded Maximum Peak Voltage 4000 650 Page No. 500 500 Connector Body Finish White Bronze White Bronze Threaded 1000 500 Nickel 17 Threaded 500 500 Silver 23 Threaded 500 500 Silver or Nickel 23 Threaded 500 500 Nickel 23 Threaded 500 500 Nickel 23 Bayonet 500 500 Silver or Nickel 41 Bayonet 500 500 Silver or Nickel 41 Bayonet 500 500 Nickel 41 Bayonet 500 500 Nickel 41 Bayonet 500 500 Nickel 41 Bayonet 500 500 Nickel 41 Bayonet 500 200 Silver or Nickel 87 Threaded (F) 500 200 Nickel 91 Push-On (G) 500 200 Nickel 91 Threaded 500 500 99 Threaded 500 500 Gold or Passivated Stainless Steel Gold or Passivated Stainless Steel Snap-On 500 100 Gold 149 Slide-On 335 500 Passivated Stainless Steel 155 Slide-On — 500 Gold 155 Gold or Passivated Stainless Steel Gold or Passivated Stainless Steel Gold or Passivated Stainless Steel Gold or Passivated Stainless Steel 155 Coupling Mechanism [N] 1 9 99 Push-On 500 5000 Push-On 335 5000 Push-On 335 5000 Push-On 250 5000 Snap-On 335 500 Nickel 177 Snap-On 500 500 Nickel 197 155 155 155 Snap-On 500 500 Nickel 197 Snap-On Snap-On Snap-On 250 250 250 5 100 100 Gold Gold Gold 207 215 223 Snap-On 500 500 Gold 233 www.amp.com/communications/com Specifications subject to change. XI Catalog 1307191 Revised 10-00 RF Coax Connectors Connector Selection (Continued) Method of Termination Construction AMP provides connectors that can be terminated to coaxial cable, printed circuit boards or other connector interfaces. The construction of a connector will greatly affect the purchase price. The connector tables in this catalog include construction details that allow you to select connectors that meet your requirements at the lowest price. Commercial designs use lower cost materials, such as zinc diecast bodies, polypropylene insulators and silver-plated contacts. Specific details of connector construction are listed in each product section of this catalog. Selection of the proper connector to terminate to an RG cable is simplified by using the format of this catalog. Experience has proven that certain connector types lend themselves to termination of particular coax cable sizes. For example, miniature cables such as RG 188 are most practically terminated to subminiature connectors such as SMB and SMC styles. Figure 3 illustrates the interface diameters of each connector type and the dielectric outside diameter (DOD) of popular RG cables. It is most economical to select a connector that terminates to a cable with a dielectric diameter close in size to the connector’s interface diameter.The product information sections of this catalog have been organized so that all connector construction types are grouped together by cable size. This allows easy selection of the connector construction best suited for the application. AMP offers a wide range of connector configurations for terminating to printed circuit boards. Also available are connectors which allow the interconnection of one interface type to another. By reviewing this catalog, a connector can be found to match most any application. Since the RF connector is a part of a transmission line system, make sure when selecting a new connector design, that it is compatible with the overall system’s performance. RG-8 RG-6 C N RG-59/62 RG-58/142 SHV BNC/TNC SMA RG-180 SMB/C RG-188 RG-178 0 0.1 0.2 0.3 Diameter (Inches) Cable Type XII Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 0.4 0.5 The materials used affect both performance and cost. Common base metals include brass, beryllium copper and stainless steel. The most common plating used for the center contact is gold because of its low contact resistance, superior mating properties and corrosion resistance. Teflon, polypropylene and polymethylpentene (TPX) are the most common connector dielectrics. Teflon offers the lowest loss, the most stable electrical properties and highest operating temperature. But since it cannot be injection molded, manufacturing is more costly than other materials. Be certain, when specifying connectors, that the temperature and voltage limitations are taken into consideration. Assembly There are several methods of assembly or termination, but they can be categorized into two major areas: (1) Solder center conductor and clamp braid (Category A) and (2) Crimp center conductor and crimp braid. Other methods are derived from combinations of the above, (e.g., solder center conductor and crimp braid. Method (1) (Category A) is generally used where no specialized tools are available, such as with field installations. With the development of low cost assembly tools, method (2) is becoming more popular for field installation. Crimping is preferred in most manufacturing environments where assembly tooling is available because terminations can be made in the least amount of time and with the greatest reliability. The design of crimp tools assures that every termination is made the same; this cannot be done with a clamp design without further testing or inspection. Figure 4 illustrates the difference between braid crimping using AMP “O” crimp and the industry-standard hex crimp. The AMP “O” crimp gives a more consistent pressure on the outer collar. In addition, the crimp of the center conductor provides superior VSWR as shown in Figure 5. Benefits derived by using AMP “O” crimp: ■ No soldering of center contact is required. This alleviates all prospective problems associated with the soldering process such as excess solder, cold solder joints and overheating the dielectric. ■ Fewer parts resulting in less assembly errors ■ Braid crimping which eliminates the need for the combing, screwing and torquing associated with the braid clamp. Connector Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Connector Selection (Continued) Figure 4 Hex Crimp vs. AMP “O” Crimp Hex Crimp Four Indent Crimp Solder AMP "O" Crimp 1 2 3 4 5 6 7 8 9 10 11 Frequency GHz Figure 5 VSWR vs. Frequency Comparison of Crimping or Soldering Center Contacts Using Series N Plug on RG-214/U Cable Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. XIII Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes XIV Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors 7-16 Series Connectors Features ■ Designed for cellular basestations, control component, antenna and broadcast applications ■ Available in White Bronze plating ■ Minimizes Intermodulation Distortion by the use of nonferrous materials ■ Hex knurl for wrench tightening ■ Available for several popular RG cable sizes in solder-clamp and crimpcrimp attachment styles AMP offers a comprehensive range of 7-16 Connectors to suit today’s challenging Wireless Infrastructure Market. This market demands reliable, intermodulation sensitive connectors that accommodate higher power. Related Product Data N Connectors — Pages 17-22 Application Notes — White Bronze Intermodulation Between Series Adapters For 7-16 Series Between Series Adapters, see Pages 255-264. AMP 7-16 Coaxial Connector Series provides reliable, intermodulationminimizing solutions that also provide a logical alternative to N Series connectors in high power applications where a more rugged interface design is required. Typical examples of this include transmitter to antenna links and channel switching networks. The 7-16 Series conforms to CECC 22190 and IEC 169-4 specification standards and has a 2.7kV working voltage at the connector interface and maximum power Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] handling capability of 4kW. The series has been designed for these demanding environments and can withstand a minimum of 500 mating cycles. Popular RG cable sizes are covered in both solder/clamp and crimp attachment styles. Two piece combination connectors adapt to straight or right angle configurations, minimizing the number of different part codes needed by the customer. Series N to 7-16 between series adapters facilitate the transition between system interfaces as well as providing a test interface. The increased customer demand for greater channel capacity combined with increased sensitivity of receivers has exposed the IMD (Intermodulation Distortion) phenomenon. To address this problem 7-16 Connectors have been designed to reduce IMD through the use of non-ferrous base materials and by silver plating of the electrical path. The proprietary White Bronze plating technique is standard, providing high corrosion resistance, low porosity, scratch resistance, low RF loss and a non-magnetic finish. Incorporation of hex-knurl coupling nuts allow for hand or wrench tightening of connectors, depending upon the application. AMP is a global ISO 9001 certified manufacturer and maintains a complete inhouse Intermodulation Testing facility. Connector part numbers shown form just a small part of the extensive interconnect package that AMP offers for the professional wireless and telecom markets. www.amp.com/communications/com Specifications subject to change. 1 Catalog 1307191 Revised 10-00 RF Coax Connectors 7-16 Series Connectors (Continued) General Specifications Materials Female Contacts (inner and outer) Other Metal Parts Insulators Gaskets Finishes Parts in the electrical path Other Metal Parts Beryllium Copper Brass Fluorocarbon Polymer Silicone Rubber Silver over copper White Bronze Electrical Frequency Range Impedance Insulation Resistance Maximum Working Voltage rms (sea level) Maximum Proof Voltage rms (sea level) Center Contact Resistance Insertion Loss VSWR Intermodulation DC-7GHz 50 Ohms 10,000 Megohms Minimum 2.7kV (connector) 1.4kV (versions for RG 213, 214 and 393) 2.7kV (connector) 1.4kV (versions for RG 213, 214 and 393) 0.8 milliohm (max.) after conditioning <1.5dB to 5 GHz 1.02 + 0.03f up to 7 GHz where f is measured in GHz Better than –150dBc Mechanical Coupling Torque Proof Torque Mechanical Endurance 18.5 – 22 ft.-lbs. 25 ft.-lbs. 500 mating cycles Environmental Temperature Rating 2 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] –55°C to +155°C www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors 7-16 Series Connectors (Continued) Straight Cable Plug Solder/Clamp 47.8 [1.88] Cable Type RG 8A/U, RG 9B/U, RG 213/U, RG 214/U Body Plating M/A-COM Model No. Part No. White Bronze D75A01B004X 1311218-1 Cable Type RG 8A/U, RG 213/U RG 9B/U, RG 214/U Body Plating White Bronze White Bronze M/A-COM Model No. D75A02B001X D75A02B004X Part No. 1331959-1 1362765-1 32.0 Dia. [1.26] Straight Cable Plug Crimp/Crimp 43.5 [1.71] 32.0 Dia. [1.26] Right Angle Cable Plug Solder/Crimp 43.0 [1.69] 36.0 [1.42] Assembled 32.0 Dia. [1.26] 34.3 [1.35] 36.0 [1.42] Cable Type RG 58C/U, RG 141A/U RG 55B/U, RG 142B/U, RG 223/U, RG 400/U RG 213/U RG 214/U RG 393 Body Plating White Bronze M/A-COM Model No. D75B02B010X Part No. 1408028-1 White Bronze D75B02B060X 1408029-1 White Bronze White Bronze White Bronze D75B03B001X D75B03B004X D75B03BB04X 1408030-1 1312113-1 1408031-1 43.0 [1.69] 32.0 [1.26] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 3 Catalog 1307191 Revised 10-00 RF Coax Connectors 7-16 Series Connectors (Continued) Right Angle Cable Plug Solder/Clamp 43.0 [1.69] 32.0 [1.26] Cable Type RG 55B/U, RG 58C/U, RG 141A/U, RG 142B/U, RG 223/U, RG 400/U T-Flex 402 Body Plating M/A-COM Model No. Part No. White Bronze D75B04B010X 1408026-1 Silver D75B01B470X 1328873-1 Cable Type RG 213/U, RG 214/U, RG 393/U RG 8A/U, RG 9B/U, RG 213/U, RG 214/U Body Plating M/A-COM Model No. Part No. White Bronze D75B04B004X 1408027-1 White Bronze D75B05B004X 1408038-1 23.2 [0.91] 43.0 [1.69] 32.0 Dia. [1.26] 47.2 [1.86] Straight Panel Mount Cable Jack Solder/Clamp 50.2 [1.97] 17.0 [0.67] Mounting Detail 24.8 [0.98] 5.00 [0.19] Cable Type RG 8A/U, RG 9B/U, RG 213/U, RG 214/U Body Plating M/A-COM Model No. Part No. White Bronze D75G01B004R 1311221-1 24.8 [0.98] 5.70 Dia [0.22] 4 Holes. 4 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 26.5 Dia. [1.04] Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors 7-16 Series Connectors (Continued) Straight Panel Mount Cable Jacks Crimp/Crimp 46.5 Assembled [1.83] Mounting Detail 44.0 [1.73] 17.2 [0.68] 5.00 [0.20] Cable Type RG 8A/U, RG 213/U RG 9B/U, RG 214/U RG 393 24.8 [0.98] Body Plating White Bronze White Bronze White Bronze M/A-COM Model No. Part No. D75G03B001R 1408032-1 D75G03B004R 1408033-1 D75G03BB04R 1408034-1 24.8 [0.98] 3.70 Dia [0.15] 4 Holes. 29.5 Dia. [1.16] Straight Panel Plug Solder Attachment 36.8 [1.45] 5.00 [0.20] 3.90 [0.15] Mounting Detail 24.8 [0.98] 32.0 Dia. [1.26] 24.8 [0.98] 3.70 Dia [0.15] 4 Holes. Body Plating White Bronze White Bronze M/A-COM Model No. D75C01B999R D75C01B999X Part No. 1331026-1 1408035-1 Body Plating White Bronze M/A-COM Model No. D75K14B999R Part No. 1311225-1 19.0 Dia. [0.75] Panel Socket Launcher Mounting Detail 21.6 [0.85] 24.8 [0.98] 24.8 [0.98] 5.00 [0.20] 3.70 Dia [0.15] 4 Holes. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 29.5 Dia. [1.16] Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 5 Catalog 1307191 Revised 10-00 RF Coax Connectors 7-16 Series Connectors (Continued) Right Angle Panel Jack Solder/Clamp 46.3 [1.82] 17.2 [0.68] Mounting Detail 5.00 [0.20] 24.8 [0.98] 24.8 [0.98] Cable Type RG 213/U, RG 214/U, RG 393 RG 58C/U, RG 142B/U, RG 223/U, RG 400/U Body Plating M/A-COM Model No. Part No. White Bronze D75G10B004R 1408036-1 White Bronze D75G09B010R 1363527-1 47.2 [1.86] 3.70 Dia [0.15] 4 Holes. Combination Series 29.5 Dia. [1.16] Right Angle Configuration The 7-16 combination series provides a cost effective and versatile method for attaching 7-16 connectors to coaxial cable. The connector front end (plug or jack interface) has two 90° diametrically opposed ports with a threaded cap for creating straight or right angle Straight Configuration configurations merely by switching the cap with a cable entry sub-assembly. The sub-assemblies are available in either crimp or clamp cable attachment styles for specified RG cables. Simply select the connector front end and the appropriate cable entry sub- assembly to make your combination connector. This versatility lowers inventory and installation costs by minimizing the number of piece parts required to assemble a maximum number of connector types. Combination Panel Jack Solder/Crimp 46.3 [1.82] 17.2 [0.68] Mounting Detail 24.8 [0.98] 5.00 [0.20] 34.2 [1.35] 24.8 [0.98] 36.7 [1.44] Assembled 3.70 Dia [0.15] 4 Holes. 6 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Cable Type RG 55B/U, RG 142B/U, RG 233/U, RG 400/U RG 8A/U, RG 213/U RG 9B/U, RG 214/U Body Plating M/A-COM Model No. Part No. White Bronze D75G07B060R 1363524-1 White Bronze White Bronze D75G08B001R D75G08B004R 1363525-1 1363526-1 29.5 Dia. [1.16] Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors 7-16 Series Connectors (Continued) Straight Adapter Plug/Plug 47.0 [1.85] 32.0 Dia. [1.26] Straight Adapter Jack/Jack Body Plating White Bronze M/A-COM Model No. D75P10B999X Part No. 1421020-1 Body Plating White Bronze M/A-COM Model No. D75P12B999X Part No. 1408062-1 Body Plating White Bronze M/A-COM Model No. D75R02B999X Part No. 1408037-1 29.0 [1.14] 34.0 Dia. [1.34] Bulkhead Adapter Jack/Jack 49.0 [1.93] 33.0 [1.30] 14.0 Max [0.55] Panel 45.0 [1.77] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 7 Catalog 1307191 Revised 10-00 RF Coax Connectors 7-16 Series Connectors (Continued) Combination Series Cable Entry Sub-Assemblies Crimp/Crimp 22.5 [1.70] Cable Type RG 55, RG 142, RG223, RG400 RG 8, RG 213 RG 9, RG 214 RG 393 RG 58, RG 141 Combination Series Cable Entry Sub-Assemblies Solder/Clamp Body Plating M/A-COM Model No. White Bronze D75X04B060X 1314660-1 White Bronze White Bronze White Bronze White Bronze D75X03B001X D75X03B004X D75X03BB04X D75X03B010X 1362390-1 1314660-1 1408039-1 1408040-1 Part No. 33.2 [1.31] Ø 19.1 [0.75] Cable Type RG 8, RG 213, RG 9, RG 214 8 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Body Plating M/A-COM Model No. Part No. White Bronze D75X01B004X 1311555-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Lightning and EMP Protection Devices Product Facts ■ Cellular operator protection against EMP (electro-magnetic pulses) caused by lightning strikes ■ Two different categories: Surge protectors and Quarter wave stub tuners ■ For use in cellular infrastructure including GSM, DCS 1800, and PCS 1900 systems ■ Incorporates Gas Discharge Tube (GDT) technology AMP has developed a unique series of Lightning and EMP protection devices for use in cellular infrastructure including GSM, DCS 1800, and PCS 1900 systems. These devices are designed to offer the cellular operator protection against EMP (electro-magnetic pulses) caused by lightning strikes. Direct or even near strikes produce fast rising electric fields within microseconds. These fields generate high voltage pulses through unprotected antennas and transmission lines which lead to the primary communication equipment. High voltage pulses can cause extensive damage leading to costly repairs as well as significant loss of service to subscribers. These protective devices come in two different categories: surge protectors and quarter wave stub tuners. To ensure that proper, low level contact resistance is established between the LP device and mounting wall, it is recommended that a minimum torque of 50 in/lbs / 5.65 n/m be applied to tighten the connector mounting nut. A recommended minimum torque of 35 in/lbs / 3.95 n/m should also be applied for installation of replacement surge protector capsules to ensure proper protection performance. In order to ensure that resultant currents from lightning or EMP strikes do not inter- Selecting your RF Coaxial Lightning Protection Device Number of Thunderstorm Days per year 05 10 15 20 30 40 50 70 90 130 150 180 Between Series Adapters For 7-16 Series and N Series Between Series Adapters, please see Pages 255-264. fere with parallel transmission lines within protected electronic equipment, surge protector devices must be installed with proper orientation. The surge protector side of the device should be mounted in the unprotected side of the equipment while the mounting nut is positioned internally in the protected area. It is important when planning lightning protection, that the user can estimate the potential number of direct strikes. This information may influence the type of device selected or the requirement for routine maintenance checks. Significant attention must be paid to the height of sup- hmax/m 10% 28 18 14 12 9.4 7.9 6.9 5.6 4.8 3.9 3.5 3.1 porting structure as this, when related to the typical number of thunderstorms in a particular region, allows us to estimate the probability of a direct strike taking place. To assist our customers in this, the following table and chart has been included in this note. This should enable lightning protection planners to establish the likelihood of direct strikes across a network anywhere in the world. Detailed application notes are available for proper selection of lightning protection devices (surge protectors & stub tuners) as well as intermodulation and White Bronze plating. hmax/m 20% 39 26 20 17 13 11 9.5 8.0 7.0 5.5 5.0 4.4 hmax/m 50% 61 40 31 26 20 17 15 12 10.6 8.5 7.7 6.9 Table 1: Maximum height of supporting building for a given number of thunderstorm days (when hmax is exceeded, probability of direct strike to supporting building within 15 years is greater than 10% for hmax values given in second column, 20% for hmax values given in third column and 50% for hmax values given in the fourth column). Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 9 Catalog 1307191 Revised 10-00 RF Coax Connectors Surge Protectors Features ■ Excellent for Broadband Frequency Applications ■ Field Replaceable Gas Discharge Tube ■ Available Interfaces Facilitate Retrofit Capabilities ■ Low VSWR up to 2.5GHz ■ Specialized White Bronze Finish Advantages ■ Broadband ■ Allows DC bias on the transmission line. (critical for applications using mast top electronics.) ■ No harmonic passband ■ Ease of retrofitting antenna sights ■ GDT easily accessible for replacement Selection of a Lightning Protection Device At right are the basic advantages and limitations for both types of protection to use in the proper selection for your application. Limitations ■ Routine maintenance recommended ■ 2.5 GHZ maximum frequency ■ Initial pass-through voltage These devices incorporate Gas Discharge Tube (GDT) technology. A GDT is a hermetically sealed tube containing an inert gas. The tube is inserted in the side of the device through an easily accessible weather sealed port. During normal operation the tube is inactive. When an installation is struck by lightning, a high voltage impulse will appear on the coaxial line. As the impulse amplitude rises, a level is reached where the impulse surpasses the dynamic voltage threshold of the tube and the electrodes arc over to discharge the energy to ground. Prior to activation of the tube, there will be a short period of time where energy will be present on the line. This RESIDUAL PULSE is equal to the dynamic voltage threshold of the tube. The maximum impulse voltage a tube can handle without discharging is referred to as the IMPULSE SPARKOVER VOLTAGE. This capacity of the GDT is quoted as follows: Characteristic Impulse sparkover voltage 10 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Symbol Definition Impulse Typical Value Dynamic voltage threshold 1kV/µS 650V Uzdyn Dimensions are in millimeters over [inches] In the case of the referenced chart, the voltage will rise at one kilovolt per microsecond and the tube will fire after 650 nanoseconds. During activation a small percentage of voltage (called ARC VOLTAGE) will still pass through. This will be approximately 30 volts. When the pulse subsides, the tube again becomes inactive leaving a small RESIDUAL VOLTAGE on the line. A direct lightning strike results in an impulse current of high amplitude. The capability of a device to protect a system is defined as the IMPULSE DISCHARGE CURRENT rating. This is defined as the peak current of an impulse which the device can withstand ten times (5 at each polarity at fixed intervals) without affecting the device. MAXIMUM IMPULSE DISCHARGE CURRENT is the peak current of an impulse the device can withstand once. Surge protectors are often used in applications requiring a standing DC line voltage. This is typical in applications with mast top electronics. The maximum voltage capacity of a surge protector prior to it surpassing the static voltage threshold and discharging it to ground is defined as its D.C. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Surge Protectors (Continued) have a finite life span which is inversely proportional to the energy dissipated. At extremes it is possible to reach a level where the tube is unable to discharge all the energy and is destroyed. It is therefore necessary to schedule routine maintenance checks and periodically replace the tube within the surge protector. SPARKOVER VOLTAGE. This capacity is quoted as follows: Characteristic Symbol Definition Impulse Typical Value d.c. sparkover voltage Uzstat Static voltage threshold n/a 230V In these applications it is important to select a device that will assure the tube can return to its inactive state after the passage of a surge. This feature of the Surge protector is known as the HOLDOVER VOLTAGE. If the device continues to conduct, the protected line will be short circuited and the tube will heat up (GLOW MODE). If left in this state, the tube can overheat and destruct. GDT’s Specifications N Series Jack to SMA Bulkhead Jack Adapter Requirement Electrical Frequency Range Impedance VSWR Performance Insertion Loss (Typical) Impulse Discharge Current (8/20µs, multiple strike) Maximum Impulse Discharge Current (8/20µs, single strike) Dynamic Sparkover Voltage, NEMP (1kV/µs) Dynamic Sparkover Voltage, LEMP (1kV/µs) Dynamic Sparkover Voltage, Static (<100V/µs) Materials Body Parts Gaskets Female Contacts Male Contacts Insulators Environmental Operating Temperature Range Relative Humidity 53.8 Ref. [2.12] 25.4 [1.00] Sq. 21.5 [0.85] Ref. 13.6 [0.54] 14.0 [0.55] M/A-COM Model Number A55X01B999X Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Surge protectors offer excellent lightning protection for broadband systems and are usable up to 2.5 GHz. Standard interfaces include 7-16, N, and SMA. Configurations include straight and bulkhead mounted adapters which allows for ease of assimilation into existing systems. Part Number 1312079-1 Dimensions are in millimeters over [inches] Detail DC to 2.5GHz 50Ω ≤1.2:1 0.2dB 20kA 50kA 2,000V 800V 230V Brass Silicone Rubber Beryllium Copper Brass P.T.F.E. -45° C to +85° C up to 100% 16.0 [0.63] Dia. Recommended Mounting Hole Frequency Range Contact Plating Body Plating Max Panel Compliant With DC to 2.5GHz Gold White Bronze 10.00mm CECC22210/ CEC22110 Coupling Torque 0.7-1.1Nm Proof Torque 1.7Nm both ends Endurance 500 Matings www.amp.com/communications/com Specifications subject to change. 11 Catalog 1307191 Revised 10-00 RF Coax Connectors Surge Protectors (Continued) N Series Bulkhead Jack to N Series Bulkhead Jack Adapter 25.4 [1.00] Sq. 53.8 Ref. [2.12] 16.0 [.063] Dia. 13.6 [.054] Recommended Mounting Hole M/A-COM Model No. N15X10B999X 7-16 Plug to 7-16 Jack Adapter 56.5 [2.23] Ref. 34.0 [1.34] Dia. Ref. Frequency Range Contact Plating Body Plating Compliant With Coupling Torque Proof Torque Endurance DC to 2.5GHz 6.0mm ± 0.5 Silver White Bronze CECC22190 25 - 30 Nm 35Nm 500 Matings Part No. 1312121-1 Gas Discharge Tube Replacement M/A-COM Model No. ST127893-98 DC to 2.5 GHz Gold White Bronze 10.00mm CECC22210 0.7-1.1 Nm 1.7 Nm 500 Matings Part No. 1312138-1 31.9 [1.25] M/A-COM Model No. D75X06B999X Frequency Range Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance Part No. 1402314-1 d.c. Sparkover Voltage: Impulse Sparkover Voltage: (1kV/mS) 230V±46V 700V typ. (900V max) Glow Discharge Voltage: Arc Discharge Voltage: a.c. Discharge Current: (1 sec, 50Hz) Impulse Discharge Current: (8/20mS waveform) 72V 10V 20A 20kA (50kA for one strike) Insulation Resistance (@100V): 10GW Capacitance: 2pF Tools & Adapters Crimping Tool M/A-COM Model No. G30040 12 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Part No. 1069249-1 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors λ/4 Stub Tuners Features ■ Ideal for use with GSM, PCS and DCS ■ Maintenance Free Operation ■ Low VSWR Within Specified Bandwidth ■ Configurations include direct attachments to Cable variants ■ Optional White Bronze Finish Advantages ■ Low VSWR in passband ■ Minimal maintenance ■ Pass-through voltage eliminated ■ No sparkover or residual voltage concerns ■ Ease of retro-fitting antenna sights These devices are three port coaxial connectors. The third port extending from the main through path is terminated in a short circuit at a pre-determined distance calculated to be exactly one quarter wavelength at the desired center frequency (see graph). Limitations ■ Frequency specific ■ Harmonic passband ■ Does not allow DC bias on transmission line Unlike surge protectors, this design eliminates concerns about residual pulse, sparkover voltage and residual voltage ensuring greater protection for sensitive electronic equipment. As opposed to surge protectors, stub tuners will absorb lightning strikes without need for replacing components. These devices yield very low VSWR and feature high attenuation within a relatively narrow pass-band (+/- 70 MHz) but are application specific. Stub tuners also pass energy in bands that are harmonically related to the fundamental center frequency. The graphs below show a typical test impulse and the response of a stub tuner. λ/4 Shorting Stub Basics li Vi Vr lr Stub tuners are classified into two broad categories— simple and broadband. The simple stub tuner exhibits a V-shaped response on the VSWR vs. frequency plot. The trough of the V is designed to occur at the required Fo and the bandwidth is restricted to approximately 8%. The broadband tuner employs extra RF techniques, similar to multiple cavity filtering, which increase the effective bandwidth by approximately 20%. AMP offers a wide variety of stub tuners for the most popular frequency bands to facilitate purchase without need for custom design and manufacturing. Designs exist for GSM, PCS 1900, DCS 1800 Dimensions are in millimeters over [inches] Typical Test Impulse V 1.0 1.9 0.5 0.3 0 01 t T T1 T1 = 1.67T T2 Typical λ/4 Test Response 326.400 110.308 V kA 244.800 94.5588 V kA 163.200 78.8088 V kA 81.6000 63.0588 V kA -640.0nS, 80.033280 V 10.98uS, 49.45920kA 0.0 uV 47.3088 kA -81.600 31.5588 V kA -163.20 V 15.8088 kA -244.80 V 58.80 A -326.40 V -15.691 kA 0.0nS 0.0nS Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 frequencies with standard industry interfaces including SMA, 7-16, and Type N. Configurations include cable assemblies, cabled connectors, and adapters for ease of assimilation into existing systems. Stub tuners are maintenance free since they incorporate no active components though it is recommended that a check of the stub tuner affixment be made following heavy discharges at an installation. 20.00uS 20.00uS 40.00uS 40.00uS www.amp.com/communications/com 60.00uS 60.00uS 80.00uS 80.00uS Specifications subject to change. 13 Catalog 1307191 Revised 10-00 RF Coax Connectors λ/4 Stub Tuners (Continued) Requirement Electrical Impedance VSWR Performance in Band Insertion Loss (Typical) DC Resistance (stub outer to inner) Dynamic Voltage @ 250A/ms Residual Voltage @ 2500A, 8/20µs Outer Conductor Contact Resistance DC Resistance (through-path center contact) Materials Body parts Gasket Female contacts Male Contacts Insulators Environmental Operating temperature range Relative humidity (non-condensing) DCS 1800 Type N Clamp Bulkhead Jack 62.9 Ref. [2.48] Detail (Type-N, 7-16) 50Ω ≤1.2:1 0.2dB 1mΩ ≤15V ≤15V 10mΩ 100mΩ Brass Silicone Rubber Beryllium Copper Brass P.T.F.E. -45°C to +85°C up to 100% 25.4 [1.00] Sq. 23.5 [0.92] Ref. 13.6 [0.54] 54.7 42.0 [2.15] [1.65] Ref. Ref. Cable T-Flex402 7-16 Jack to 7-16 Bulkhead Jack Adapter M/A-COM Model No. N15X12E470X 77.6 Ref. [3.06] 16.0 Dia. [0.63] Recommended Mounting Hole 44.9 Dia. [1.77] Ref. 30.5 [1.20] 67.0 [2.64] 44.6 Ref. [1.76] Ref. 3.20 [0.13] Recommended Mounting Hole 14 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 ± 70 MHz 1795 MHz 6.0mm±0.5 Silver 6.0mm±0.5 Silver 10.00mm CECC22210 0.7-1.1Nm 1.7Nm 500 Matings Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance ± 70 MHz 1795 MHz 6.0mm±0.5 Silver White Bronze 8.00mm CECC22190 25 - 30Nm 35Nm 500 Matings Part No. 1329818-1 17.5 [0.69] M/A-COM Model No. D75X15B999X Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance Part No. 1361137-1 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors λ/4 Stub Tuners (Continued) DCS 1800 (Continued) Type N Crimp Bulkhead Jack 62.9 Ref. [2.48] 25.4 [1.00] Sq. 23.5 [0.92] Ref. 13.6 [0.54] 42.0 [1.65] Ref. Cable RG58C/U Type N Jack to Type N Bulkhead Jack Adapter 23.5 [0.93] Ref. 13.6 [0.54] 10.0 [0.39] 54.7 42.0 [2.15] [1.65] Ref. Ref. 77.6 Ref. [3.06] 16.0 Dia. [0.63] Recommended Mounting Hole 44.9 Dia. [1.77] Ref. 27.4 [10.8] Ref. 30.5 Dia. [1.20] 17.5 [0.69] Recommended Mounting Hole M/A-COM Model No. D75X07B999X 23.5 [0.92] Ref. 25.4 [1.00] Sq. 13.6 [0.54] 52.9 40.2 [2.08] [1.58] Ref. Ref. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 ± 70 MHz 1795 MHz 6.0mm±0.5 Silver 6.0mm±0.5 Silver 10.00mm CECC22210 0.7-1.1Nm 1.7Nm 500 Matings Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance ± 70 MHz 925 MHz 6.0mm±0.5 Silver White Bronze 8.00mm CECC22190 25 - 30Nm 35Nm 500 Matings Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance ± 70 MHz 1920 MHz 6.0mm±0.5 Silver 6.0mm±0.5 Silver 10.00mm CECC22210 0.7-1.1Nm 1.7Nm 500 Matings Part No. 1312122-1 62.9 Ref. [2.48] Cable T-Flex 402 Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance Part No. 1361138-1 93.4 [3.68] 71.0 Ref. [2.79] Ref. PCS 1900 Type N Clamp Bulkhead Jack ± 70 MHz 1795 MHz 6.0mm±0.5 Silver 6.0mm±0.5 Silver 10.00mm CECC22210 0.7-1.1Nm 1.7Nm 500 Matings Part No. 1329819-1 25.4 [1.00] Sq. M/A-COM Model No. N15X16E999X 16.0 Dia. [0.63] Recommended Mounting Hole M/A-COM Model No. N15X18E010X 57.3 Ref. [2.26] GSM 7-16 Bulkhead Jack to 7-16 Bulkhead Jack 54.7 [2.15] Ref. Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance M/A-COM Model No. N15X09E470X Dimensions are in millimeters over [inches] 16.0 Dia. [0.63] Recommended Mounting Hole Part No. 1312137-1 www.amp.com/communications/com Specifications subject to change. 15 Catalog 1307191 Revised 10-00 RF Coax Connectors λ/4 Stub Tuners (Continued) PCS 1900 (Continued) Type N Crimp Bulkhead Jack 62.9 Ref. [2.48] 25.4 [1.00] Sq. 23.5 [0.92] 13.6 [0.54] 52.9 40.2 [2.08] [1.58] Ref. Ref. Cable RG58 C/U 7-16 Clamp Bulkhead Jack 27.4 [1.08] Ref. M/A-COM Model No. N15X14E010X 24.6 [0.97] Ref. Recommended Mounting Hole 27.5 [1.08] 4.00 Ref. [0.16] 29.5 Dia. [1.16] 40.2 Ref. [1.58] Recommended Mounting Hole Cable T-Flex402 7-16 Bulkhead Jack to 7-16 Bulkhead Jack Adapter M/A-COM Model No. D75X12E470X 77.6 Ref. [3.06] 44.9 Dia. [1.77] Ref. 30.5 [1.20] 17.5 [0.69] Recommended Mounting Hole Type N Bulkhead Jack to Type N Bulkhead Jack Adapter 57.3 Ref. [2.26] 25.4 [1.00] Sq. 16.0 [0.63] Dia. 40.0 [1.58] Ref. 16 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 1920 MHz ± 70 MHz 6.00mm ± 0.5 Silver 6.00mm ± 0.5 Silver 8.00mm CECC 22190 25-30 Nm 35 Nm 500 Matings Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance 1920 MHz ± 70 MHz 6.00mm ± 0.5 Silver White Bronze 8.00mm CECC 22190 25-30 Nm 35 Nm 500 Matings Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance ± 70 MHz 1920 MHz 6.0mm±0.5 Silver 6.0mm±0.5 Silver 10.00mm CECC22210 0.7-1.1Nm 1.7Nm 500 Matings Part No. 1312124-1 52.7 [2.08] Ref. M/A-COM Model No. N15X17E999X Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance Part No. 1312123-1 64.6 [2.54] Ref. 42.2 [1.66] Ref. M/A-COM Model No. D75X14B999X ± 70 MHz 1920 MHz 6.0mm±0.5 Silver 6.0mm±0.5 Silver 10.00mm CECC22210 0.7-1.1Nm 1.7Nm 500 Matings Part No. 1312139-1 72.7 Ref. [2.86] 38.0 Dia. [1.50] Ref. 16.0 Dia. [0.63] Bandwidth Center Frequency Contact Plating Body Plating Max Panel Compliant With Coupling Torque Proof Torque Endurance 13.6 [0.54] Recommended Mounting Hole Part No. 1361139-1 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors N Series Connectors Product Facts ■ Designated connectors are MIL-C-39012, Class II, Category B qualified ■ Captive center contacts ■ Completely crimpable application – one hand tool crimps all cables with single or double braided shields of a given size ■ Impedance matching crimps ■ Broad band performance – low VSWR ■ Superior cable retention ■ TEFLON dielectric ■ Silver or nickel finish ■ Fully intermateable with MIL-C-39012 connectors ■ Listed under the Component Program of Underwriters Laboratories Inc., File No. E81956 R ■ Recognized under the Component Program of Underwriters Laboratories Inc., File No. E81956 R ■ Certified by Canadian Standards Association File No. LR 7189 R The AMP N Connector, featuring a 15.88 [5/8] - 24 threaded coupling for optimum stability, is highly suited for critical applications and environments. This medium sized connector can withstand shock and vibration to assure a low noise level and has a constant impedance of 50 ohms. It also features a captive center contact and provides excellent performance at frequencies up to 11 GHz, with voltages to 1000 volts rms. This AMP connector offers the added benefits of low overall applied cost with a labor-saving two-crimp assembly. The contact is simply crimped to the cable’s center conductor, then both braid and cable support are simultaneously crimped to complete the termination. N Series Connectors are available in standard plug, jack, panel jack, bulkhead jack and right-angle plug configurations. Those connectors with a military designation (M39012) are furnished in accordance with all requirements of specification MIL-C-39012, Class II, Category B. Materials Brass — QQ-B-626 Beryllium Copper — QQ-C-530 Dielectric — TEFLON TEFLON — MIL-P-19468 Copper, Annealed — QQ-C-576 Phosphor Bronze — QQ-B-750 Silicone Rubber — ZZ-R-765 Between Series Adapters Plating For N Series Between Series Adapters, see Pages 255-264. Body — Silver per QQ-S-365 Nickel per QQ-N-290 Center Contact — Gold per MIL-B-45204 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Electrical Characteristics Mechanical Characteristics Nominal Impedance — 50 ohms Working Voltage — 1000 volts, rms at sea level Frequency Range — 0 to 11 GHz Voltage Standing Wave Ratio (VSWR) — Straight Plug or Jack1.3:1 max. Right-Angle Plug— 1.35 max. at 0 to 9.0 GHz 1.50 max. at 9.0 to 11.0 GHz Contact Resistance — Outer Contact — 0.2 milliohms Center Contact — 1.0 milliohms Right-Angle — 2.5 milliohms Insulation Resistance — 5000 megohms min. Dielectric Withstanding Voltage — 2500 Volts, rms at sea level RF Leakage — Mil Type, -90 dB min. at 2 to 3 GHz RF Insertion Loss — Mil Type, 0.15 dB max. at 10 GHz Right-Angle Plug, 0.3 dB max. at 10 GHz Corona Level — Mil Type, 500 volts min. at 21 336 m [70,000 ft.] Terminator — Resistance — 50 ohms ±1% Power Rating — 1.0 watt max. Mating/Unmating — Threaded coupling Cable Attachment — Crimp type center contact and braid Coupling Nut Retention — 445 N [100 lbs.] min. Cable Retention — 400 N [90 lbs.] min. RG 214/U Cable Durability — 500 cycles per MIL-C39012 Captive Contact — 27 N [6 lbs.] min. axial retention, either direction Environmental Characteristics Temperature Range — Mil Type, -65°C to +165°C Commercial, -55°C to +85°C Vibration — MIL-STD-202, Method 204, Test Cond. B Shock — MIL-STD-202, Method 213, Test Cond. I Moisture Resistance — MIL-STD202 Method 106 Salt Spray — MIL-STD-202, Method 101, Test Cond B Temperature Cycling — MIL-STD202, Method 107, Test Cond. B (except high temperature is +85°C) Note: All data pertains to use with MIL-C39012 specified cables only. www.amp.com/communications/com Specifications subject to change. 17 Catalog 1307191 Revised 10-00 RF Coax Connectors N Series Connectors, 50 Ohm (Continued) Plugs Mil Type Dual Crimp Semi-Rigid Cable 19.05 Dia. [.750] Max. 58, 58A, 58B, 58C 58A,58C 223, 55, 55A, 55B 142, 142A 142B, 400 21.01 Dia. [.827] Max. 21.01 Dia. [.827] Max. L Max. RG/U Cable Hex Dual Crimp L Max. L Max. Termination Type Body Plating M39012/ Military No. and/ or Comments Dim. L Integral Die Hand Tool O Crimp Nickel Knurl Collar 220045-2 — — 1-225661-2* O Crimp Silver Knurl Collar 220045-2 — — 225361-1* Hex Crimp Nickel Knurl Collar 58436-1** 1.73 .068 5.41 .213 415232-2 O Crimp Nickel Knurl Collar 220045-2 — — 1-225661-3* O Crimp Silver Knurl Collar 220045-2 — — 225361-2* O Crimp Nickel Knurl Collar 220045-2 — — 1-225661-5* O Crimp Silver Knurl Collar Knurl Collar 42.85 1.687 42.85 1.687 39.40 1.550 42.85 1.687 42.85 1.687 42.85 1.687 42.85 1.687 39.40 1.550 39.40 1.550 Knurl Collar 42.85 1.687 Hex Collar 142, 142A 142B Hex Crimp 115A, Belden 89880, 9880 O Crimp Nickel Nickel Hex Across Flats Center Braid 220045-2 — — 225361-4* 58436-1** 5.41 .213 5.41 .213 415232-3 58436-1** 1.73 .068 1.73 .068 220015-1 — — 225092-8 39.40 2.54 10.90 58485-1** 1.550 .100 .429 39.40 2.54 10.90 Knurl Collar 58485-1** 1.550 .100 .429 402 Semi Rigid 24.6 — — — Solder Nickel Knurl Collar (.141) .970 405 Semi Rigid 24.6 — — — Solder Nickel Knurl Collar (.085) .970 42.85 O Crimp Nickel Knurl Collar 220015-1 — — 1.687 42.85 8, 8A, 213 O Crimp Nickel Knurl Collar 220015-1 — — 1.687 01B0007 42.85 O Crimp Silver 220015-1 — — Knurl Collar 1.687 39.40 2.54 10.90 Hex Collar 58485-1** 1.550 .100 .429 8, 213 Hex Crimp Nickel 39.40 2.54 10.90 Knurl Collar 58436-1** 1.550 .100 .429 01B0013 42.85 11, 11A, 216 O Crimp Silver 220015-1 — — Knurl Collar 1.687 47.22 Belden 9292 O Crimp Nickel — 220015-1 — — 1.859 39.40 2.54 10.90 393 Hex Crimp Nickel Hex Collar 58485-1** 1.550 .100 .429 42.85 Belden 8214 O Crimp Nickel Knurl Collar 220015-1 — — 1.687 42.85 O Crimp Nickel Knurl Collar 220015-1 — — 1.687 9, 9A, 9B, 01B0008 42.85 O Crimp Silver 220015-1 — — 214 Knurl Collar 1.687 42.85 O Crimp Nickel Knurl Collar 220015-1 — — 1.687 39.40 2.54 10.90 Hex Collar 58485-1** 1.550 .100 .429 9, 214 Hex Crimp Nickel 39.40 2.54 10.90 Knurl Collar 58485-1** 1.550 .100 .429 *Hand Tool 69710-1, with Die Insert 220062-1, is available to terminate these connectors. The 626 Pneumatic tool system can also be used. **Die Set Crimp Tool — Pro Crimper II Hand Tool, P/N 354940-1 or 626 Series Pneumatic Tool with 679304-1. Hex Collar Belden 9880 18 Hex Crimp Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 415232-4 415232-9 Nickel Dimensions are in millimeters over [inches] www.amp.com/communications/com 1-415232-0 1057088-1 1057094-1 1-227086-0 225661-2 51692-2 415232-5 415232-6 51692-4 1-225662-8 1-415232-1 1-225661-6 225661-1 51692-1 1-227086-1 415232-7 415232-8 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors N Series Connectors, 50 Ohm (Continued) 35.86 Max. [1.412] L Max. Right Angle Plugs, Crimp 21.01 Dia. [.827] Max. RG/U Cable Termination Type Body Plating M39012/ Military No. and/ or Comments Dim. L Integral Die Hand Tool 58A, 58C Hex Crimp Nickel Hex Collar 58436-1* 142, 142A, 142B Hex Crimp Nickel Hex Collar O Crimp Nickel Knurl Collar Silver 05B0002 Knurl Collar 57.79 2.275 57.79 2.275 57.79 2.275 57.79 2.275 57.79 2.275 57.79 2.275 57.79 2.275 57.79 2.275 57.79 2.275 57.79 2.275 8, 8A, 213 O Crimp 8, 213 Hex Crimp Nickel Hex Collar 393 Hex Crimp Nickel Hex Collar O Crimp Nickel Knurl Collar Silver 05B0003 Knurl Collar 9, 9A, 9B 214 O Crimp 9, 214 Hex Crimp Nickel Hex Collar Belden 9880 Hex Crimp Nickel Hex Collar Hex Across Flats Center Braid Part No. 5.41 .213 5.41 .213 415255-1 58436-1* 1.73 .068 1.73 .068 220015-1 — — 225669-2 415255-2 220015-1 — — 225014-2 58485-1* 10.90 .429 10.90 .429 415255-3 58485-1* 2.54 .100 2.54 .100 220015-1 — — 225669-1 415255-6 220015-1 — — 225014-3 58485-1* 2.54 .100 2.54 .100 10.90 .429 10.90 .429 415255-4 58485-1* 415255-5 *Crimp Tool — Pro Crimper II Hand Tool, P/N 354940-1 or 626 Series Pneumatic Tool with 679304-1. Jacks L Max. 15.93 Dia. [.627] Max. RG/U Cable Termination Type Body Plating M39012/ Military No. and/ or Comments Dim. L Integral Die Hand Tool 58A, 58C Hex Crimp Nickel — 58436-1** 142, 142A, 142B, 400 142, 142A, 142B 8, 8A, 213 O Crimp Nickel — 41.28 1.625 44.84 1.765 41.28 1.625 49.2 1.937 41.28 1.625 49.2 1.937 41.28 1.625 41.28 1.625 41.28 1.05 26.7 1.625 26.7 1.05 Hex Crimp Nickel — O Crimp Silver 02B0008 8, 213 Hex Crimp Nickel — 9, 9A, 9B, 214 O Crimp Silver 02B0009 9, 214 Hex Crimp Nickel — Belden 9880 Hex Crimp Nickel — 393 Hex Crimp Nickel — 402 Semi Rigid (.141) 405 Semi Rigid (.085) Solder Nickel — Solder Nickel — Hex Across Flats Center Braid 1.73 .068 Part No. 5.41 .213 415242-1 220045-2** — — 1-225663-5* 58436-1** 1.73 .068 5.41 .213 415242-2 220015-1 — — 225093-2 58485-1** 2.54 .100 10.90 .429 415242-3 220015-1 — — 225093-1 58485-1** 10.90 .429 10.90 .429 10.90 .429 415242-4 58485-1** 2.54 .100 2.54 .100 2.54 .100 — — — 1057116-1 — — — 1057119-1 58485-1** 415242-5 415242-6 *Hand Tool 69710-1, with Die Insert 220062-1, is available to terminate these connectors. The 626 Pneumatic tool system can also be used. **Die Set Crimp Tool — Pro Crimper II Hand Tool, P/N 354940-1 or 626 Series Pneumatic Tool with 679304-1. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 19 Catalog 1307191 Revised 10-00 RF Coax Connectors N Series Connectors, 50 Ohm (Continued) 16/16.38 [.630/.645] Dia. Bulkhead Jacks, Crimp 13.51/13.79 [.532/.543] L Max. 22.48 Dia. [.885] Max. Maximum Panel Thickness 6.35 [.250] Recommended Panel Cutout Hex Across Flats Center Braid RG/U Cable Termination Type Body Plating Dim. L Integral Die Hand Tool 58, 58A, 58B, 58C O Crimp Silver 220045-2 — — 225363-1* 58A, 58C Hex Crimp Nickel 58436-1** 1.73 .068 5.41 .213 415248-1 223, 55, 55A, 55B 142, 142A, 142B, 400 142, 142A, 142B O Crimp Silver 220045-2 — — 225363-2* O Crimp Silver 49.6 1.953 45.72 1.800 49.6 1.953 49.6 1.953 45.72 1.800 45.21 1.780 49.61 1.953 45.72 1.800 45.72 1.800 45.72 1.800 45.72 1.800 49.61 1.953 Hex Crimp Nickel O Crimp Silver O Crimp Nickel 124, 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269, 89269 Belden 9880 Hex Crimp Nickel 8, 213 Hex Crimp Nickel 393 Hex Crimp Nickel 9, 214 Hex Crimp Nickel 9, 9A, 9B 214 O Crimp Nickel Part No. 220045-2 — — 225363-4* 58436-1** 1.73 .068 5.41 .213 415248-2 220045-3 — — 225363-6 220045-3 — — 1-225667-6 58485-1** 10.90 .429 10.90 .429 10.90 .429 10.90 .429 415248-5 58485-1** 2.54 .100 2.54 .100 2.54 .100 2.54 .100 220015-1 — — 225667-1 58485-1** 58485-1** 415248-3 415248-6 415248-4 *Hand Tool 69710-1, with Die Insert 220062-1, is available to terminate these connectors. The 626 Pneumatic tool system can also be used. **Crimp Tool — Pro Crimper II Hand Tool, P/N 354940-1 or 626 Series Pneumatic Tool with 679304-1. 16.26 +0.13 -0.25 Dia. [.640 +.005 ] -.010 Bulkhead Jacks for Semi-Rigid Cable 12.88 +0.08 -0.05 Dia. [.507 +.003 ] -.002 Front Mount Rear Mount 5.59 +0.03 -0.05 [.220 +.001 ] -.002 13.72 +0.08 -0.2 [.540 +.003 ] -.008 Maximum Panel Thickness 6.35 [.250] 22.86 Dia. [.900] Max. L Max. 16.1 Dia. [.630] Max. L Max. Maximum Panel Thickness 6.35 [.250] Recommended Panel Cutout RG/U Cable 402 Semi-Rigid/.141 405 Semi-Rigid/.085 Recommended Panel Cutout Termination Type Body Plating M39012/ Military No. and/or Comments Crimp Nickel Rear Mount Crimp Nickel Front Mount Solder Nickel Rear Mount Solder Nickel Rear Mount Dim. L Integral Die Hand Tool Part No. 29.37 1.156 29.37 1.156 25.4 1.00 33.9 1.335 * 228658-1 * 228448-1 — 1057176-1 — 1057165-1 *Tooling—Hand Tool No. 59980-1, Requires (2) Crimping Dies No. 312253-1 and (1) Locator No. 220220-2. 20 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors N Series Connectors, 50 Ohm (Continued) Jack, Panel Mount 16.25 Dia. [.640] Min. 25.40 [1.000] 18.24 ± .013 [.718 ± .005] 18.24 ± .013 [.718 ± .005] L Max. 3.17 [.125] Dia. (4 Holes) Min. Recommended Panel Cutout RG/U Cable Termination Type Body Plating Dim. L Die Set 58A, 58C Hex Crimp Nickel 58436-1 142, 142A, 142B Hex Crimp Nickel 8, 213 Hex Crimp Nickel 9, 214 Hex Crimp Nickel Belden 9880 Hex Crimp Nickel 41.28 1.625 41.28 1.625 41.28 1.625 41.28 1.625 41.28 1.625 58436-1 58485-1 58485-1 58485-1 Hex Across Flats Center Braid 1.73 .068 1.73 .068 2.54 .100 2.54 .100 2.54 .100 Part No. 5.41 .213 5.41 .213 10.90 .429 10.90 .429 10.90 .429 415252-3 Body Plating NIckel Nickel Nickel M/A-COM Model No. 3052-0000-10 3052-1200-10 3052-1201-10 Part No. 1057284-1 1057286-1 1057290-1 Body Plating NIckel Nickel Nickel M/A-COM Model No. 3051-0000-10 3051-1201-10 3051-1200-10 Part No. 1057275-1 1057279-1 1057277-1 415252-1 415252-2 415252-4 415252-5 *Crimp Tool — Pro Crimper II Hand Tool, P/N 354940-1 or 626 Series Pneumatic Tool with 679304-1. 25.0 [.986] 18.7 [.736] 2.0 [.080] Panel Jacks, Solder 18.2 [.718] Typ. 3.0 Dia. [.120] 2.5 Dia. [.098] 9.6 Ref. [.377] Panel Plug, Solder 25.4 Sq. [1.000] Ø 3.2 Dia. [.125] 4 Plcs. 27.2 [1.070] 20.8 [.819] 2.0 [.080] 25.4 Sq. [1.000] 18.2 [.718] Typ. Ø 3.0 [.120] Ø 2.5 [.098] Ø 3.2 4 Plcs. [.125] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 21 Catalog 1307191 Revised 10-00 RF Coax Connectors N Series Connectors, 50 Ohm (Continued) Feed-Thru Jack Adapter (Jack-Jack) Contact — Gold plated Part No. 227945-2 Plating Body — Nickel Dielectric — General purpose polypropylene 45.22 Max. [1.780] 15.93 Dia. [.627] Max. Inter-Series Adapters 50.69 [1.996] 40.5 [1.59] Ref. 20.6 Dia. [0.81] Ref. Part No. 1311318-1 M/A-COM Model No. N15P10E999X Body Plating White bronze Stainless steel/ passivate 22 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 1057374-1 M/A-COM Model No. 3082-0000-10 Gold Teflon M/A-COM Model No. N15P10E999X Gold Teflon 3082-0000-10 Contact Dimensions are in millimeters over [inches] Dielectric www.amp.com/communications/com Part No. 1311318-1 1057374-1 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors Product Facts Hex Crimp and O Crimp Connectors ■ 50 and 75 ohm commercial versions available ■ Provides excellent performance at frequencies up to 7 GHz ■ Low cost commercial type available ■ Commercial type is smaller and lighter weight ■ Tarnish resistant nickel finish ■ Choice of dielectric materials ■ Standard and weatherproof versions available ■ Plugs available for high temperature cable Single Crimp Connectors ■ Fast application–one crimping operation terminates inner conductor, outer braid and cable support ■ Low application cost Connectors for Semi-Rigid Cable ■ Crimp and solder versions available ■ Standard cable stripping dimensions ■ Universal cable termination common to all configurations The AMP TNC RF connector family, with 7/16-28 threaded couplings, provides low noise levels and optimum stability, and can withstand the shock and vibration often present in hostile environments. Available in both 50 and 75 ohm versions, these connectors feature numerous styles including cable plugs and jacks, adapters and printed circuit board connectors. These connectors accept a wide range of coaxial cables and are intermateable with industry standard connectors designed to MIL-C-39012 specifications. Single crimp connectors provide reduced application time and lower applied costs. This is accomplished by using AMP one-crimp operation tooling which simultaneously terminates the inner conductor, outer braid and cable support with one controlled stroke. AMP can also supply lowcost alternatives with a commercial type product line. These connectors are designed around the milspecifications, offering comparable mechanical and electrical performance. Listed under the Component Program of Underwriters Laboratories Inc., File No. E81956 R PC Board connectors are recognized under the Component Program of Underwriters Laboratories Inc., File No. E81956 R Certified by Canadian Standards Association File No. LR 7189 Related Product Data R Military Category — All crimp connectors are Category B Type (AMP Crimp Tooling), unless otherwise noted. Packaging — All Mil-Type connectors are packaged individually and all Commercial connectors are bulk packaged unless otherwise noted. Between Series Adapters For TNC Between Series Adapters, see Pages 255-264. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 23 Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors (Continued) Specifications Characteristics Single Crimp (Mil Type) Category B O Crimp (Mil Type) Commercial O Crimp & Hex Crimp 50 & 75 Ohm Commercial PCB Commercial Solder Jacks Semi-Rigid Solder Clamp 50 50 50 50 50 50 50 Electrical Impedance, Nom. (Ohms) Working Voltage (Volts RMS) Contact Resistance (Milliohms) Initial Insulation Resistance (Megohms) Dielectric Withstanding Voltage (VAC) Corona Level at 70,000 ft. (Picocoulombs) RF Leakage, Max. (dB) RF Insertion Loss, Max. (dB) Frequency Range (GHz) VSWR in Frequency Range Max. 500 500 500 500 500 335 500 Inner: 1.5 Outer: 3 Inner: 1.5 Outer: 0.2 Inner: 2.0 Outer: 0.3 Inner: 6.0 Outer: 3.0 Inner: 2.75 Outer: 1.0 Inner: 1.5 Outer: 0.2 Inner: 1.5 Outer: 0.2 5000 5000 5000 5000 5000 5000 5000 1500 1500 1500 1500 1500 1500 1500 5 max. @ 375 VRMS 5 max. @ 375 VRMS 55 @ 2-3 GHz 0.2 @ 3 GHz — — — — — 5 max. @ 375 VRMS 60 @ 2-3 GHz 0.18 @ 9 GHz — — 5 max. @ 375 VRMS 60 @ 2-3 GHz 0.06 @ 3-6 GHz 5 max. @ 375 VRMS 55 @ 2-3 GHz 0.2 @ 3 GHz 0-4 0-11 0-7 0-4 0-4 0-15 0-11 1.35 1.3 1.40 — — 1.35 1.30 @ 4 GHz 10/2 [44.5/8.9] 100 [444.8] 60 [266.9] RG58C/U 500 25 [2.8] 2/2 [8.9/8.9] 100 [444.8] 60 [266.9] RG58C/U 500 25 [2.8] 6/6 [26.7/26.7] 60 [266.9] 60 [266.9] RG58C/U 500 25 [2.8] — — — — 60 [266.9] (PCB Ret) 500 25 [2.8] 500 25 [2.8] 2 [.023] 100 [444.8] 60 [266.9] 500 25 [2.8] 2 [.023] 100 [444.8] 40 [178.0] 500 25 [2.8] -65 to +85 — Mechanical Force to Engage/ Couple, lbs. [N] Coupling Nut Retention, Min. lbs. [N] Cable Retention, lbs. [N] Durability (Cycles) Jam Nut Mounting Torque, Max. lbs. [N•m] — Environmental Temperature Range, Operating (C°) Thermal Shock MIL-STD-202 Method 107 -65 to +1651 -55 to +852 MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. I, (100 G’s) MIL-STD-202 Method 107 Cond. B Moisture Resistance MIL-STD-202 Method 106 MIL-STD-202 Method 106 Salt Spray MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. I, (100 G’s) MIL-STD-20 Method 107 Cond. A MIL-STD-202 Method 106 Type II MIL-STD-202 Method 101 Cond. B — 108-12001 108-12046 Vibration Physical Shock Product Specification MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G, (50 G’s) -55 to +85 -55 to +85 -65 to +165 -65 to +105 -65 to +165 MIL-STD-202 Method 201A Cond. A MIL-STD-202 Method 213 Cond. I, (100 G’s) MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. I, (100 G’s) MIL-STD-202 Method 202 Cond. B MIL-STD-202 Method 213 Cond. I MIL-STD-202 Method 202 Cond. B MIL-STD-202 Method 213 Cond. I MIL-STD-202 Method 107 MIL-STD-202 Method 107 MIL-STD-202 Method 107 MIL-STD-202 Method 107 MIL-STD-202 Method 106 MIL-STD-202 Method 106 MIL-STD-202 Method 106 MIL-STD-202 Method 106 MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 101 Cond. B — — 108-12032 — Assembled to cable with polytetrafluorethylene dielectric. Assembled to cable with polyethylene dielectric. 1 2 24 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors (Continued) Specifications (Continued) Commercial O Crimp & Hex Crimp 50 & 75 Ohm Commercial PCB Commercial Solder Jacks Semi-Rigid Solder Clamp Brass QQ-B-626 — — Brass QQ-B-626 Brass QQ-B-626 Brass MIL-C-21768 — — Brass QQ-B-626 Brass QQ-B-626 Brass QQ-B-626 Zinc QQ-Z-363 Zinc QQ-Z-363 Zinc QQ-Z-363 Brass QQ-B-626 Brass QQ-B-626 TEFLON MIL-P-19468 TEFLON MIL-P-19468 Polyethylene Polypropylene Gen. Purpose Polypropylene Gen. Purpose1 TEFLON MIL-P-19468 Polyester PBT MIL-P-24519 TEFLON MIL-P-19468 TEFLON MIL-P-19468 Brass QQ-B-626 Beryl. Copper ASTM-B-643, QQ-C-530 Silicon Rubber QQ-R-765 Copper QQ-C-576 Brass QQ-B-626 Beryl. Copper ASTM-B-643, QQ-C-530 Silicon Rubber QQ-R-765 Copper QQ-C-576 Brass QQ-B-626 — — Brass QQ-B-626 Brass QQ-B-626 Beryl. Copper QQ-C-530 Phos. Bronze QQ-B-570 Phos. Bronze QQ-B-570 Beryl Copper QQ-C-530 Beryl Copper QQ-C-530 Silicon Rubber QQ-R-765 Copper QQ-C-576 — — Silicone Rubber QQ-R-765 Silicone Rubber QQ-R-765 — — — — Collar Silver QQ-S-365 Silver QQ-S-365 — — Nickel QQ-N-290 Nickel QQ-N-290 Outer Contact (Plug & Jack) Silver QQ-S-365 Bright Nickel QQ-N-290 Bright Nickel QQ-N-290 Bright Nickel QQ-N-290 Nickel QQ-N-290 Nickel QQ-N-290 Center Contact (Plug & Jack) Gold MIL-G-45204 Silver QQ-S-365 Tin Lead, ASTM-B-545 Silver, QQ-S-365 Gold, MIL-G-45204 Tin Lead, ASTM-B-545 Silver, QQ-S-365 Gold, MIL-G-45204 Gold MIL-G-45204 Gold MIL-G-45204 Silver QQ-S-365 Gold MIL-G-45204 Bright Nickel QQ-N-290 Bright or Matte Nickel QQ-N-290 Tin Lead, ASTM-B-545 Silver, QQ-S-365 Gold, MIL-G-45204 Tin Lead ASTM-B-5 — — — — Single Crimp (Mil Type) Category B O Crimp (Mil Type) Brass QQ-B-626 Phos. Bronze QQ-B-750 Beryl. Copper QQ-C-530 Brass QQ-B-626 Phos. Bronze QQ-B-750 Beryl. Copper QQ-C-530 Brass QQ-B-626 Dielectric Center Contact (Plug) Characteristics Connector Material Collar Outer Contact (Plug) Outer Contact (Jack) Center Contact (Jack) Gasket Ferrule Connector Primary Finishes Ferrule 2 Several pc board connectors have an outer polyester PBT insulator per MIL-P-24519. If several finishes are listed, refer to individual catalog page(s) or customer drawings for exact specifications. 1 2 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 25 Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm Plugs, Crimp Hex Crimp and O Crimp Mil Type O Crimp Weatherproof L Max. 13.21 Dia. [.520] Max. RG/U Cable 174, 188, 188A, 316 179, 179A, 179B 161, 187, 187A Belden 9221 RD316 188 Double Braid 180, 180A, 180B 195, 195A Center Termination Contact Type Plating 16.26 Dia. [.640] Max. Body Plating Dielectric Style Comments CERTI-CRIMP Dim. Hand Tool L with Integral Die L Max. Interchangeable Dies for Interchangeable PRO-CRIMPER Dies for Hand Hand Tool Tool 69710-1 354940-1 or & 626 Pneu. PRO-CRIMPER Head 318161-1 Adapter 679304-1 Part No. Hex Crimp Gold Nickel Polypropylene Commercial — 31.24 1.230 — 58436-3 — 222506-5 Hex Crimp Gold Nickel Polypropylene Commercial — 31.24 1.230 — 58436-3 — 222506-6 Hex Crimp Gold Nickel Polypropylene Commercial — — 58436-3 — 222506-9 Hex Crimp Gold Nickel Polypropylene Commercial — — 58436-3 — 222506-7 Hex Crimp Gold Nickel Polypropylene Commercial — — 58436-1 — 222506-1 O Crimp Gold Silver TEFLON Mil Type — 220045-2 — — 225550-2 O Crimp Gold Nickel TEFLON Mil Type Weatherproof 220045-2 — — 225555-2 O Crimp Gold Nickel Polypropylene Commercial — 220187-1 58435-11 220217-1 227000-5 Hex Crimp Gold Nickel Polypropylene Commercial — — 58436-1 — 1-222506-1 Hex Crimp Gold Nickel Polypropylene Commercial — — 58436-1 — 222506-4 O Crimp Gold Silver TEFLON Mil Type — 220045-2 — — 225345-6 O Crimp Gold Silver TEFLON Mil Type Weatherproof 220045-2 — — 225550-6 O Crimp Gold Nickel TEFLON Mil Type Weatherproof 220045-2 — Gold Nickel Polypropylene Commercial — Gold Nickel Polypropylene Commercial — 8, 8A, 213 O Crimp Gold Nickel TEFLON Mil Type Weatherproof 31.24 1.230 31.24 1.230 31.25 1.230 34.93 1.375 34.93 1.375 26.8 1.055 31.24 1.230 31.24 1.230 34.29 1.350 34.93 1.375 34.93 1.375 29.72 1.170 26.8 1.055 50.8 2.000 Alpha 9847, Belden 8213, 9292 O Crimp Gold Silver TEFLON Mil Type Weatherproof 50.68 1.995 220015-1 — — 1-225550-3 225, 393 O Crimp Gold Silver TEFLON Mil Type Weatherproof 220015-1 — — 1-225550-2 O Crimp Gold Silver TEFLON Mil Type — 220015-1 — — 225345-8 O Crimp Gold Silver TEFLON Mil Type Weatherproof 220015-1 — — 225550-8 O Crimp Gold Nickel TEFLON Mil Type Weatherproof 50.8 2.000 50.8 2.000 50.8 2.000 50.8 2.000 220015-1 — — 225555-8 58, 58A, 58B, 58C 58, 58A, 58B, 58C 141, 141A, 303 223, 55, 55A, 55B 142, 142A 142B, 400 124, 140, 210, Hex Crimp 62, 62A, 62B, 59, 59A, 59B Belden 9291, 9209, 9269 O Crimp 9, 9A, 9B, 214 2 — 225555-6 — 58436-1 2 — 222506-2 — 58435-11 — 227000-7 220015-1 — — 225555-7 Order AMP PRO-CRIMPER Coaxial “O” Crimp Hand Tool assembly 58433-1, which includes dies 58435-1. Order AMP PRO-CRIMPER Coaxial Hex Crimp Hand Tool assembly 58433-2, which includes dies 58436-1. 1 2 26 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm Plug Plugs, Solder/Clamp A 14.4 Dia. [.570] B A/F RG/U Cable RG58C/U, RG141A/U RG174A/U, RG188A/U, RG316/U RG55B/U, RG142B/U, RG223/U, RG400/U Termination Type Center Contact Plating Body Plating Dielectric Style Dim. A Dim. B M/A-COM Model No. Part No. Solder Clamp Gold Nickel Teflon Mil Type 1311379-1 Gold Silver Teflon Mil Type 11.1 .437 11.1 .437 T35A70J010X Solder Clamp 28.5 1.12 28.5 1.12 T35A70E010X 1311378-1 Solder Clamp Gold Nickel Teflon Mil Type 28.5 1.12 11.1 .437 T35A70J022X 1328461-1 Solder Clamp Gold Nickel Teflon Mil Type 28.5 1.12 11.1 .437 T35A70J060X 1362489-1 Plugs for Semi Rigid-Cable 19.6 Ref. [.770] A Dia. 16.5 Dia. [.650] Max. B Dia. 16.26 Dia. [.640] Max. 23.4 [.921] Max. Solder Type Crimp Type RG/U Cable 402 Semi-Rigid/ 3.66 [.141] RG402/U .141 3.66 [.141] Center Termination Contact Type Plating Body Plating Dielectric Style Comments Dim. A Interchangeable Dies for PRO-CRIMPER Dim. Hand Tool B 354940-1 or PRO-CRIMPER Adapter 679304-1 Interchangeable Dies for Hand Tool 69710-1 M/A Com & 626 Pneu. Model No. Head 318161-1 Part No. Crimp Gold Nickel Teflon Commercial Weather proof — — 1 2 — 228179-3 Solder Gold Gold Solid PTFE Mil Type — 3.7 .144 4.6 .180 — 3 3101-7941-00 1057631-1 Hand Tool 59980-1, Requires (2) Crimping Dies 312253-1 and (1) Locator 312644-1. Pneumatic Tool 58318-1, Requires (2) Crimping Dies 313720-1 and (1) Locator 312645-1. Refer to Recommended Assembly Tools in Tool Section. 1 2 3 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 27 Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Right Angle Plugs, Crimp O Crimp Mil Type O Crimp Weatherproof 31.75 [1.250] 27.43 Max. [1.080] L Max. L Max. 16.26 Dia. [.640] Max. 13.21 Dia. [.520] RG/U Cable 174, 174A, 188 188A, 316 RD 188, 316 Double Braid 58, 58A, 58B 58C 58, 58A, 58B, 58C 141, 141A, 303 55, 55A, 55B 223 Center Contact Plating Body Plating Dielectric Style Comments Dim. L CERTI-CRIMP Hand Tool with Integral Die O Crimp Gold Nickel Commercial — — 318450-2 414173-3 O Crimp Gold Nickel Polymethylpentene Polymethylpentene Commercial — — 58539-1 414173-4 O Crimp Gold Nickel TEFLON Mil Type Weatherproof 220045-2 — 225559-2 Commercial — — 220189-1 414173-1 Commercial — — 220189-1 414173-6 Commercial — — 220189-1 414173-5 220045-2 — 225554-6 Part No. O Crimp Gold Silver TEFLON Mil Type Weatherproof 38.23 1.505 38.23 1.505 47.63 1.875 38.23 1.505 38.23 1.505 38.23 1.505 47.63 1.875 124, 140, 210, 62 62A, 62B, 59, 59A 59B, Belden 9291 9209, 9269 O Crimp Gold Nickel Polymethylpentene Commercial — 38.23 1.505 — 220189-2 414173-2 8, 8A, 213 O Crimp Gold Nickel TEFLON Mil Type Weatherproof 220015-1 — 225559-8 393, 225 O Crimp Gold Silver TEFLON Mil Type Weatherproof 220015-1 — 1-225554-1 9, 9A, 9B, 214 O Crimp Gold Silver TEFLON Mil Type — 63.5 2.500 63.5 2.500 59.52 2.343 220015-1 — 225349-9 142, 142A, 142B 400 28 Termination Type Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 O Crimp Gold Nickel O Crimp Gold Nickel O Crimp Gold Nickel Polymethylpentene Polymethylpentene Polymethylpentene Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Jacks, Crimp O Crimp Mil Type O Crimp Weatherproof L Max. 11.43 Dia. [.450] Max. L Max. 11.43 Dia. [.450] Max. RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric Style Comments Dim. L CERTI-CRIMP Hand Tool with Integral Die Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 174, 174A, 188 188A, 316 RD 188, 316 Double Braid 58, 58A, 58B 58C 58, 58A, 58B, 58C 141, 141A, 303 O Crimp Gold Nickel Commercial — — 318450-2 414171-3 O Crimp Gold Nickel Polymethylpentene Polymethylpentene Commercial — — 58539-1 414171-4 O Crimp Gold Silver TEFLON Mil Type Weatherproof 220045-2 — 225551-2 O Crimp Gold Nickel Polymethylpentene Commercial — — 220189-1 414171-1 141, 141A, 303 O Crimp Gold Silver TEFLON Mil Type Weatherproof 220045-2 — 225551-5 O Crimp Gold Nickel Polymethylpentene Commercial — — 220189-1 414171-6 O Crimp Gold Silver TEFLON Mil Type — 220045-2 — 225551-1 Commercial — — 220189-1 414171-5 220045-2 — 225551-6 — 220189-2 414171-2 55, 55A, 55B 223 142, 142A, 142B 400 124, 140, 210, 62 62A, 62B, 59, 59A 59B, Belden 9291 9209, 9269 O Crimp Gold Nickel Polymethylpentene O Crimp Gold Silver TEFLON Mil Type Weatherproof 30.48 1.200 30.48 1.200 35.72 1.406 29.85 1.175 35.72 1.406 29.85 1.175 35.72 1.406 34.29 1.350 35.72 1.406 O Crimp Gold Nickel Polymethylpentene Commercial — 29.85 1.175 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Part No. Specifications subject to change. 29 Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Jacks, Solder/Clamp 33.3 [1.31] 14.3 Dia. [.562] 12.7 A/F [.500] 30 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 11.1 A/F [.437] RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric Style M/A-COM Model No. Part No. RG58C/U, RG141 A/U Solder/Clamp Gold Silver Teflon Mil Type T35E60E010X 1312569-1 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Bulkhead Jacks, Crimp Single Crimp O Crimp H H L Max. L Max. +.013 -.000 12.83 +0.05 Dia. [.505 -0.00] 5.54 [.218 +.008 -.000 +0.03 -0.00 ] Maximum Panel Thickness Single Crimp 3.18 [.125]; Dual Crimp 6.35 [.250] Recommended Panel Cutout H= 11/16 [.6875] max. across flats, 20.32 [.800] max. across points. RG/U Cable 174, 174A, 316 188, 188A 179, 179A, 179B 161, 187, 187A Belden 9221 RD 188, 316 Double Braid 58, 58A, 58B, 58C 58, 58A, 58B, 58C 141, 141A, 303 223 55, 55A, 55B 142, 142A 142B, 400 120, 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269 Termination Type Center Contact Plating Body Plating Dielectric Style Comments Dim. L CERTI-CRIMP Hand Tool with Integral Die Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 O Crimp Gold Nickel Polymethylpentene Commercial — 34.93 1.375 — 318450-2 414168-3 Single Crimp Gold Nickel TEFLON Mil Type — 38.1 1.500 69245-1 — 331238 O Crimp Gold Nickel Polymethylpentene Commercial — — 58539-1 414168-4 O Crimp Gold Nickel TEFLON Mil Type Weatherproof 220045-2 — 225557-2 O Crimp Gold Nickel Commercial — — 220189-1 414168-1 O Crimp Gold Nickel Commercial — — 220189-1 414168-6 O Crimp Gold Nickel Polymethylpentene Polymethylpentene Polymethylpentene Commercial — — 220189-1 414168-5 O Crimp Gold Nickel TEFLON Mil Type Weatherproof 34.93 1.375 38.1 1.500 34.93 1.375 34.93 1.375 34.93 1.375 38.1 1.500 220045-2 — 225557-6 O Crimp Gold Nickel Polymethylpentene Commercial — 34.93 1.375 — 220189-2 414168-2 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Part No. Specifications subject to change. 31 Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Bulkhead Jacks Solder/Clamp 12.0 A/F [.470] 17.5 [.690] 12.9 Dia. [.510] A A/F 15.8 A/F [.620] Recommended Panel Cutout 17.5 A/F [.690] RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric Style M/A Com Model No. Part No. RG58 C/U, RG141 A/U Solder Clamp Gold Silver Teflon Mil Type T35H39E010X 1328580-1 Bulkhead Jacks for Semi-Rigid Cable, Rear Mount +.013 12.83 -.000 Dia. +0.05 [0.505 -0.00 ] +.008 5.54 -.000 +0.03 [.218 -0.00 ] H L Max. Maximum Panel Thickness 6.35 [.250] Recommended Panel Cutout H= 17.45 [.687] max. across flats, 20.32 [.800] max. across points. RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric Style Dim. L Part No. Crimp Gold Nickel Teflon Mil Type 25.4 1.000 228502-1 Crimp Gold Nickel Teflon Mil Type 29.7 1.169 228507-1 402 Semi-Rigid/ 3.66 [.141]* 405 Semi-Rigid/ 2.18 [.086]** *Tooling—Hand Tool 59980-1, Requires (2) Crimping Dies 312253-1 and (1) Locator 220220-2. **Tooling—Hand Tool 59980-1, Requires (2) Crimping Dies 312253-2 and (1) Locator 220221-2. 30.5 Ref. [1.200] 20.9 [.821] 12.1 [.475] Min. 6.40 Max. [.250] Panel A Dia. 12.7 Dia. [.500] Min. B Dia. Recommended Panel Cutout RG/U Cable RG 402/U 3.66 [.141] RG 405/U 2.16 [.085] 32 15.9 Hex. [.625] 19.1 Hex. [.750] Termination Type Center Contact Plating Body Plating Dielectric Style Dim. A Dim. B M/A-COM Model No. Part No. Solder Gold Solid PTFE Mil Type Solid PTFE Mil Type 4.6 .180 3.0 .120 1057676-1 Gold 3.7 .144 2.3 .089 3104-7941-00 Solder Pass. Stainless Steel Pass. Stainless Steel 3104-7985-00 1057679-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Panel Jacks, Crimp 11.2 Dia. [.441] Min. 12.7 ±0.1 [.500 ±.004 ] 12.7 ±0.1 [.500 ±.004 ] 2.71 Dia. [.107] Min. Clearance for 3-56 Screws (4 Holes) 17.86 Sq. [.703] Max. L Max. Recommended Panel Cutout RG/U Cable 58, 58A, 58B, 58C Termination Type Center Contact Plating Body Plating Dielectric Style Dim. L CERTI-CRIMP Hand Tool With Integral Die Part No. Crimp Gold Silver Teflon Mil Type 34.93 1.375 220045-2 225348-2 Panel Jacks for Semi-Rigid Cable 22.9 [.900] 16.3 [.642] 14.3 [.562] 17.5 Sq. [.687] 12.7 [.500] Typ. A Dia. B Dia. 3.20 Dia. [.125] 4 Plcs. RG/U Cable RG 402/U 3.66 [.141] RG 405/U 2.16 [.085] Termination Type Center Contact Plating Body Plating Dielectric Style Solder Gold Gold Teflon Mil Type Solder Gold Gold Teflon Mil Type Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Dim. A Dim. B M/A-COM Model No. Part No. 3.7 .144 Min. 2.3 .089 Min. 4.6 .180 3.0 .120 3106-7941-00 1057697-1 3106-7985-00 1057699-1 www.amp.com/communications/com Specifications subject to change. 33 Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Right Angle PC Board/Panel Mount Jacks VALOX Body Metal Body 1/2-28 Thread 1/2-28 Thread 15.88 [.625] Mtg. Hgt. +0.13 12.83 -.000 [.505 +0.05 ] -0.00 Dia. C L B A 15.88 [.625] Mtg. Hgt. C L 34.93 [1.375] A B 34.93 [1.375] +.008 5.54 -.000 [.218 +0.03 ] -0.00 Body Material Maximum Panel Thickness 6.1 [.240] Recommended Panel Cutout Center Contact Plating  VALOX, White 50 Gold Metal 50 Gold Part Numbers Without With Mounting Posts Mounting Posts Dimensions A B 8.56 .337 8.26 .325 21.21 .835 20.83 .820 Without Mounting Posts 2.64 [.104] Dia. Clearance Holes (2) For 2-56 Self-Tapping Screws* 5.08 ± 0.05 [.200 ± .002] Mating Face 0.89 ± 0.08 Dia. [.035 ± .003] (2 Holes) 2.54 ± 0.05 [.100 ± .002] (Top View) Vertical PC Board/Panel Mount Jacks G 2.01 ± 0.08 Dia. [.079 ± .003] (2 Holes) 5.08 ± 0.05 [.200 ± .002] 5.08 ± 0.05 [.200 ± .002] Mating 0.89 ± 0.08 Dia. Face [.035 ± .003] (2 Holes) S G 2.54 ± 0.05 [.100 ± .002] VALOX Body (Top View) Metal Body 1/2-28 Thread 1/2-28 Thread 15.88 [.625] 15.88 [.625] B Lockwasher and Jam Nut B 34.93 [1.375] Mtg. Hgt. Body Material Center Contact Plating Dimension B VALOX, White Gold Metal Gold 21.21 .835 20.83 .820 Part No. 1-329631-2 227816-1 227820-1 — 227835-1 With Mounting Posts 2.64 [.104] Dia. Clearance Holes (2) For 2-56 Self-Tapping Screws* ±0.05 2.54 [.100 ±.002] 10.16 ±0.08 [.400 ±.003] G S 10.16 ±0.08 [.400 ±.003] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] 2.01 ±0.08 Dia. [.079±.003] (2 Holes) 5.08 ±0.05 [.200 ±.002] 5.08 ±0.05 [.200 ±.002] 2.54 ±0.05 [.100 ±.002] 10.16 ±0.08 [.400 ±.003] G S 10.16 ±0.08 [.400 ±.003] 0.89 ±0.08 Dia. [.035 ±.003] (2 Holes) (Top View) 34.93 [1.375] Mtg. Hgt. Part Numbers Without Mounting Posts With Mounting Posts Without Mounting Posts 5.08 ±0.05 [.200 ±.002] 34 227839-1 Recommended PC Board Layouts *2-56 Self-Tapping Screws: For 1.57 [3/32] or greater panel thickness Part No. 221108-2 For less than 1.57 [3/32] panel thickness Part No. 221108-4 Part No. 1-329632-2 227838-1 10.16 ± 0.08 [.400 ± .003] 5.08 ± 0.05 [.200 ± .002] S 227818-1 With Mounting Posts 10.16 ± 0.08 [.400 ± .003] G 227812-1 Recommended PC Board Layouts 5.08 ±0.05 [.200 ±.002] 0.89 ±0.08 Dia. [.035 ±.003] (2 Holes) (Top View) www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Right Angle PC Board/Mount Jacks 16.64 [.655] 23.62 [.930] Plating Body — Nickel Center Contact — Gold Dielectric — TEFLON 27.96 [1.101] 28.98 [1.141] Part No. 413933-1 6.60 [.260] 2.74 Dia. [.108] 2 Holes 6.60 [.260] 5.59 [.220] 3.30 [.130] 6.60 [.260] 16.51 [.650] 6.60 [.260] 8.26 [.325] 2.29 Dia. [.090] 2 Holes 3.30 [.130] 3.43 Dia. [.135] 2 Holes 3.30 [.130] 3.43 Dia. [.135] 2 Holes 3.30 8.26 [.130] [.325] 1.27 Dia. [.050] Part No. 414449-1 2.29 Dia. [.090] 2 Holes 1.27 Dia. [.050] 2.79 [.110] 2.79 [.110] Hole for #4 Self Tapping Screw Recommended PC Board Cutouts Accepts 1.5 Dia. Max. Wire [.059] Bulkhead Solder Jacks 9.65 [.380 Insulation Bushing L Max. Material — Nylon Part No. 227223-1 0.89 [.035] +0.13 -.000 +.005 Dia. -.000 ] 3.96 [.156 4.04 Max. [.159] 11.43 [.450] 22.23 [.875] 13.09 Dia. [.515] Max. 0.89 [.035] +0.08 -.000 +.003 Dia. -.000 ] Recommended Panel Cutout (Jack) Max. Panel Thickness Refer to chart below. 14.86 [.585] 9.53 [.375] 10.93 [.430] Max. 11.56 ±0.08 Dia. [.455 ±.003] 10.97 [.432 Body Plating Center Contact Plating Dielectric Nickel Gold VALOX Nickel Gold VALOX ±0.08 ±.003] Dim. L Panel Thickness 26.93 1.060 33.33 1.312 1.02-3.96 .040-.156 1.17-6.35 .046-.250 Part Numbers With Without Solder Terminal Solder Terminal 227760-2 227758-2 227762-2 227764-2 Recommended Panel Cutout (Bushing) Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 35 Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Panel Mount Jack Receptacles 25.9 Ref. [1.000] 19.1 Sq. [.750] 10.1 [.750] Center Contact Plating Nickel Plated Brass 13.5 [.531] Typ. 2.0 [.080] 1.6 Dia. [.062] M/A-COM Model No. Part No. 3152-0000-10 1057775-11 Captured Center Contact - Solder Pot Terminal 1 2.2 Dia. [.086] 3.2 Dia. [.125] 4 Plcs. Flange Mount Receptacles 37.0 [1.455] 10.1 [.750] 2.0 [.080] 15.0 [.590] 19.1 [.750] Sq. 7.0 Dia. [.275] Center Contact Plating Nickel Plated Brass Nickel Plated Brass 13.5 [.531] Typ. 2.2 Dia. [.086] 3.2 Dia. [.125] 4 Plcs. M/A-COM Model No. Part No. 3152-1200-10 1057777-11 3152-1201-10 1057780-12 Non Captured Center Contact - Straight Terminal Captured Center Contact - Straight Terminal 1 2 Jack-Jack Adapter Center Contact Plating Gold 12.96 Dia. [.510] Max. Body Plating Dielectric Part No. Nickel Polypropylene 221325-1 36.2 Max. [1.425] Bulkhead Jack-Jack Adapter +0.13 12.83 -.000 [.505 +.005 ] -0.00 Dia. Center Contact Plating Gold Body Plating Dielectric Part No. Nickel Acetal 221500-1 +0.08 5.54 -.000 [.218 +.003 ] -0.00 40.14 Max. [1.580] Maximum Panel Thickness 6.35 [.250] Recommended Panel Cutout Part No. 221500-1 36 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 50 Ohm (Continued) Vertical Jack PC Board/Panel Mount Left Hand Thread Lockwasher and Jam Nut See page 34 +0.13 20.78 ± 0.38 [.818 ± .015] 12.83 -.000 [.505 +.005 ] -0.00 Dia. 12.70 ± .008 [.500 ± 0.02] Center Contact Plating Gold 0.94 ± 0.06 [.037 ± .002] Body Plating Dielectric Part No. Nickel Acetal 415188-1 +0.08 0.99 ± 0.06 [.037 ± .002] 6.35 ± 0.25 [.250 ± .010] 5.54 -.000 [.218 +.003 ] -0.00 6.35 ± 0.06 [.250 ± .002] Recommended Panel Cutout Recommended PC Board Cutout Plug, Crimp Left Hand Thread L RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric Style Dim. L Tooling Part No. Belden 9907, 89907, 8219, CommScope 3104, 2104, RG141, 141A, 303 Hex Crimp Gold Nickel PTFE Commercial 31.24 1.230 Use Hand Tool 354940-1 with Die Set 58536-1 415000-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 37 Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 75 Ohm Plugs, Crimp Hex Crimp and O Crimp These connectors have been designed for optimum performance and have a true 75 ohm impedance the complete length of the connector. The crimp die tooling listed below is different from the equivalent 50 ohm connectors. 12.96 Dia. [.510] Max. L Max. Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Part No. 58425-2 413591-8 318451-2 221506-3 58174-1 221506-5 58425-1 413591-2 58536-1 221506-1 RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric Style Dim. L 179, 179A, 179B 187, 187A Belden 9221 Hex Crimp Gold Nickel Commercial O Crimp Gold Nickel O Crimp Gold Nickel Hex Crimp Gold Nickel O Crimp Gold Nickel Polymethylpentene Polymethylpentene Polymethylpentene Polymethylpentene Polymethylpentene Commercial 31.75 1.250 27.79 1.094 29.46 1.160 31.75 1.250 29.21 1.150 Hex Crimp Gold Nickel Polymethylpentene Commercial 31.75 1.250 58425-1 413591-1 Hex Crimp Gold Nickel Polymethylpentene Commercial 31.75 1.250 58425-3 413591-6 Hex Crimp Gold Nickel Polymethylpentene Commercial 31.75 1.250 58425-1 413591-9 Hex Crimp Gold Nickel Commercial 413591-7 Gold Nickel 58536-1 221506-4 Hex Crimp Gold Nickel 58425-3 413591-5 O Crimp Gold Nickel 31.75 1.250 29.21 1.150 31.75 1.250 32.9 1.295 58425-1 O Crimp Polymethylpentene Polymethylpentene Polymethylpentene Polymethylpentene 58538-1 221506-2 AT&T 735A 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209 9269 302 Belden 88241 89269 Hi-Temp 62A Times PL62, Berk-Tek BTDC-59, BTDC-62 Double Shield RG-59 Belden 9104, 9112 9240, 9167, 9259, 9266, Times FM-59 Belden 9145 AT&T 734A Belden 8281 9141, 9231 Commercial Commercial Commercial Commercial Commercial Commercial Bulkhead Jack, Crimp +0.13 12.83 -.000 [.505 +.005 ] -.000 Dia. +0.08 5.54 -.000 [.218 +.003 ] -.000 H 34.29 Max. [1.350] Maximum Panel Thickness 6.35 [.250] Recommended Panel Cutout Part No. 221509-1 RG/U Cable 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9169, 89269 38 Termination Type Center Contact Plating Body Plating Dielectric Style O Crimp Gold Nickel Polymethylpentene Commercial Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Dim. H 11/16 across flats, 20.32 .800 max. across points Tooling Part No. Use Hand Tool 354940-1 with Die Set 58536-1 221509-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors, 75 Ohm (Continued) Right-Angle PC Board/Panel Mount Jacks Metal Body 1/2-28 Thread 15.88 [.625] Mtg. Hgt. +0.13 12.83 -.000 [.505 +0.05 ] -0.00 Dia. C L A B 34.93 [1.375] +.008 5.54 -.000 [.218 +0.03 ] -0.00 Body Material  Maximum Panel Thickness 6.1 [.240] Metal Recommended Panel Cutout 75 Center Contact Plating A B Gold 8.26 .325 20.83 .820 Dimensions Part Numbers Without With Mounting Posts Mounting Posts — 413506-1 Bulkhead Jack-Jack Adapter Center Contact Plating Gold Body Plating Dielectric Part No. Nickel Polymethylpentene 414396-1 Body Plating Nickel Part No. 40.14 Max. [1.580] Male Dust Cap with Chain 57.15 [2.25] 14.73 Ref. [.580] 414910-1 3.66 Ref. [.144] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 39 Catalog 1307191 Revised 10-00 RF Coax Connectors TNC Connectors Part No. 1055469-1 M/A-COM Model No. 2098-5274-54 Inserts Locator Tool Solder Gage Center Contact Holder Fixture Sub-Assembly For installation of TNC (OST) Series connectors to 3.66 [.141] and 2.16 [.085] diameter semi-rigid cable. Most BNC (OSB) Series connectors can also be assembled using this kit. See appropriate assembly procedure for specific tooling. This kit contains: Description Center Contact Holder Fixture Sub-Assembly Inserts – 2.16 [.085] (2) Inserts – 3.66 [.141] (2) Locator Tool Locator Tool Solder Gage .813 [.032] Model No. T-4580 T-4567 T-4700-2 T-4700-1 T-4596 T-4574 T-4562-6 NSN M/A-COM No. –– –– 5120-00-132-6808 5120-00-132-6807 –– –– –– 2098-5279-10 2098-5206-54 2098-5208-54 2098-5207-54 2098-5282-02 2098-5283-02 2098-5281-02 Part No. 1055474-1 1055439-1 1055441-1 1055440-1 1055476-1 1055477-1 1055475-1 All Tools May Be Purchased Separately. 40 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors (50 ohm/75 ohm) Product Facts ■ Bayonet lock coupling for quick connect/disconnect ■ Various connectors available in 50 and 75 ohm versions ■ Fully intermateable with comparable BNC UG/U connectors ■ Full range of Hex Crimp and O Crimp Products for common coaxial cables. ■ Low VSWR ■ Single crimp connectors offer one crimping operation for fast application ■ Twist-on connectors require no special tooling for application to the cable ■ Field serviceable (Category A) connectors qualified to MIL-C-39012 ■ Field replaceable (Category C) plugs with captivated center contact ■ Field replaceable plugs can be terminated with industry standard tooling ■ Tarnish resistant Nickel finish available ■ Choice of different dielectrics ■ Listed under the Component Program of Underwriters Laboratories Inc., File No. E81956 R ■ PC Board soldered connectors are recognized under the Component Program of Underwriters Laboratories Inc., File No. E81956 The AMP BNC RF connector family with bayonet locking coupling provides highly reliable, quick connect / disconnect coaxial connections. Exclusive single and O crimp terminations allow positive insulation grip and require no soldering, providing terminations at a very low overall applied cost. Available in both 50 and 75 ohm versions, these connectors feature numerous styles including cable plugs and jacks, adapters and printed circuit board connectors. In addition to a variety of crimp type terminations, connectors are furnished in field replaceable and twist-on styles. These connectors accept a wide range of coaxial cables and are intermateable with industry standard connectors designed to MIL-C39012 specifications. AMP can also supply low cost alternatives with an extensive commercial type product line. A lower cost consumer series product offers the capability to supply center contacts in strip form and allow for automated center contact crimp technology. All connectors are designed around the mil-specifications, but utilize low-cost materials, offering comparable mechanical and electrical performance. 108-12002 — BNC Commercial T Adapter 108-12095 — BNC Commercial 75 Ohm Connectors 108-12096 — BNC Commercial FeedThru and Bulkhead Adapters 108-12079 — BNC Commercial 50 Ohm Solder Jacks 108-12103 — BNC Commercial PCB Press Fit Jacks Application Specifications — 114-12001 — BNC Commercial PCB Jack Press Fit Performance Specifications — Page 42 Material Specifications — Page 43 Tooling — Pages 265-268 Military Category — All mil type O crimp connectors are Category B Type (AMP Crimp Tooling), unless otherwise noted. Packaging — All Mil Type connectors are packaged individually, all O crimp connectors are bulk packaged and all Hex crimp connectors are individually packaged unless otherwise noted. R ■ Certified by Canadian Standards Association File No. LR 7189 R Between Series Adapters For BNC Between Series Adapters, see Pages 255-264. Related Product Data Product Specifications — 108-1275 — BNC Ohm Terminators 108-12020 — BNC O Crimp Connectors 108-12044 — BNC Commercial Hex Crimp 108-12047 — BNC Commercial and Hex Crimp Connectors 108-12074 — BNC Solder Jacks 108-12075 — BNC Connectors (Category A) 108-12078 — BNC Commercial PCB Panel-Mount Jacks Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 41 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors (50 ohm/75 ohm) Performance Specifications Characteristics Electrical Impedance, Nom. (Ohms) Working Voltage (Volts RMS) Contact Resistance (Milliohms) Initial Insulation Resistance (Megohms) Dielectric Withstanding Voltage (VAC) Corona Level at 70,000 ft. (Volts, RMS) RF Leakage, Max. (dB) RF Insertion Loss, Max. (dB) Frequency Range (GHz) VSWR in Frequency Range Max. Mechanical Force to Engage (lbs. [N])/couple, (in-lbs. [N-M]) max. Coupling Nut Retention, Min. N [lbs.] Cable Retention, N [lbs.] Durability (Cycles) Jam Nut Mounting Torque, Max. [N•m] (in. lbs.) Environmental Temperature Range, Operating (C°) Vibration Physical Shock Single Crimp (Mil Type) Category B O Crimp (Mil Type) Straight Solder Clamp Right Angle Solder Clamp Commercial O Crimp & Hex Crimp 50 Ohms Commercial O Crimp & Hex Crimp 75 Ohms Commercial PC Board 50 & 75 Ohms Commercial Solder 50 Ohm Jacks 50 50 50 50 50 75 50 & 75 50 & 75 500 500 500 500 500 500 500 500 Inner: 1.5 Outer: 0.3 Inner: 1.5 Outer: 0.2 Inner: 1.5 Outer: .20 Inner: 1.5 Outer: .20 Inner: 2.0 Outer: 1.0 Inner: 2.0 Outer: 2.0 Inner: 6/1.5 Outer: 3/0.2 Inner: 2.75 Outer: 1.0 5000 5000 5000 5000 5000 5000 5000 5000 1500 1500 1500 1500 1500 1500 1500 1500 375 375 375 375 375 375 — 375 — -55 at 2-3 GHz 0.2 at 3 GHz -55 at 2-3 GHz 0.2 at 3 GHz -55 at 2-3 GHz 0.3 at 3 GHz -55 at 2-3 GHz 0.2 at 3 GHz -55 at 1-2 GHz 0.15 at 2 GHz — — — — 0-4 — 0-2.5 0-4 0-4 0-4 0-4 0-2 0-4 and 0-2 1.35 1.30 1.30 1.35 1.30 1.30 — — 13.3/11.12 [3/2.5] 444.8 [100] 266.9 [60] (RG58C/U) 500 25 [2.8] 13.3/11.12 [3/2.5] 444.8 [100] 266.9 [60] (RG58C/U) 500 25 [2.8] 13.3/.028 [3/2.5] 444.8 [100] 177.9 [40] (RG58C/U) 500 25 [2.8] 13.3/.028 [3/2.5] 444.8 [100] 177.9 [40] (RG58C/U) 500 26.7/26.69 [6/6.0] 266.9 [60] 266.9 [60] (RG58C/U) 500 25 [2.8] 26.7/26.69 [6/6.0] 266.9 [60] 266.9 [60] (RG58C/U) 500 25 [2.8] — — — — 266.9 [60] (PCB Ret) 500 253/124 [2.8/1.4] 500 25 [2.8] -55 to +85 -65 to +165 MIL-STD-202 Method 201A -65 to +1651 -55 to +852 MIL-STD-202 MIL-STD-202 Method 204 Method 204 Cond. B Cond. B MIL-STD-202 MIL-STD-202 Method 213 Method 213 Cond. G, 50 G’s Cond. G, 50 G’s -65 to +85 — -65 to +165 -65 to +165 -55 to +85 -55 to +85 MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. G MIL-STD-1344 Method 2005 Cond. III MIL-STD-1344 Method 2004 Cond. G, 100 G’s MIL-STD-1344 Method 1003 Cond. A MIL-STD-1344 Method 1002 Type II MIL-STD-1344 Method 1001 Cond. B 108-12044 108-12047 MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. I, 100 G’s MIL-STD-202 Method 213 Cond. I or A, 50 G’s MIL-STD-202 Method 204 Cond. B MIL-STD-202 Method 213 Cond. I, 100 G’s MIL-STD-202 Method 107 MIL-STD-202 Method 107 MIL-STD-202 Method 107 MIL-STD-202 Method 106 MIL-STD-202 Method 106 MIL-STD-202 Method 106 MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 101 Cond. B 108-12095 108-12078 108-12079 Thermal Shock MIL-STD-202 Method 107 MIL-STD-202 Method 107 MIL-STD-202 Method 107 MIL-STD-202 Method 107 Moisture Resistance MIL-STD-202 Method 106 MIL-STD-202 Method 106 MIL-STD-202 Method 106 MIL-STD-202 Method 106 Salt Spray MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 101 Cond. B MIL-STD-202 Method 101 Cond. B 108-12002 108-12020 — — Product Specification — Assembled to cable with polytetrafluorethylene dielectric. Assembled to cable with polyethylene dielectric. 3 For Metal Threads 4 For Polyester Threads 1 2 42 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors (50 ohm/75 ohm) Performance Specifications (Continued) Connector Component Single Crimp (Mil Type) Category B&C O Crimp (Mil Type) Straight Solder Clamp Right Angle Solder Clamp Commercial O Crimp Hex Crimp & Terminators Commercial PCB Solder Commercial PCB Press Fit Commercial Solder Ohm Jacks Brass QQ-B-626 Brass QQ-B-626 Beryl. Copper QQ-C-530 Brass QQ-B-626 Brass Brass Brass QQ-B-626 Zinc QQ-Z-363 — — — Phos. Bronze QQ-B-750 Brass Brass Brass MIL-C-21768 — — — Zinc QQ-Z-363 Zinc Zinc QQ-Z-363 Adapters Connector Material Collar Outer Contact (Plug) Brass QQ-B-626 Brass QQ-B-626 Beryl. Copper QQ-C-530 Shell (Jack) Brass QQ-B-626 Brass QQ-B-626 Brass — Zinc QQ-Z-363 Dielectric TEFLON MIL-P-19468 Polypropylene Gen. Purpose TEFLON MIL-P-19468 TEFLON TEFLON Polyethylene Polypropylene Polymethylpentene Gen. Purpose Center Contact (Plug) Brass QQ-B-626 Brass QQ-B-626 Brass Brass Brass QQ-B-626 — — — Center Contact (Jack) Beryl. Copper ASTM-B-643 QQ-C-530 Beryl. Copper ASTM-B-643 QQ-C-530 Beryl. Copper Beryl. Copper Beryl. Copper QQ-C-530 Phos. Bronze QQ-B-750 Beryl. Copper QQ-C-530 Phos. Bronze QQ-B-570 Beryl. Copper QQ-C-530 Silicon Rubber QQ-R-765 Copper Ferrule QQ-C-576 Connector Primary Finishes2 Silicon Rubber QQ-R-765 Copper QQ-C-576 Silicon Rubber Silicon Rubber — — — — — Silicon Rubber QQ-R-765 Copper QQ-C-576 TEFLON MIL-P-19468 Polypropylene, Gen. Purpose Brass QQ-B-626 Beryl. Copper QQ-C-530 Phos. Bronze QQ-B-570 Beryl. Copper QQ-C-530 Silicon Rubber QQ-R-765 — — — — Silver/ Bright Nickel Silver/ Bright Nickel Bright Nickel QQ-N-290 — — — — Tin Lead ASTM-B-545 — — — Gasket Collar Silver QQ-S-365 Bright Nickel QQ-N-290 Silver QQ-S-365 Bright Nickel QQ-N-290 Silver QQ-S-365 Bright Nickel QQ-N-290 Outer Contacts (Plug & Jack) QQ-S-365 Gold Center Contacts (Plug & Jack) MIL-G-45204 Silver Gold MIL-G-45204 Gold Ferrule3 QQ-S-365 Silver QQ-S-365 Tin Lead ASTM-B-545 — Silver/ Bright Nickel Polymethylpentene TEFLON MIL-P-19468 Gen. Purpose1 QQ-Z-363 Brass QQ-B-626 TEFLON MIL-P-19468 Polyester PBT MIL-P-24519 Brass QQ-B-626 Silver QQ-S-365 Bright Nickel QQ-N-290 Silver Bright or Silver/ Bright Nickel Bright Nickel Bright Nickel QQ-S-365 Matte Nickel Bright Nickel QQ-N-290 QQ-N-290 QQ-N-290 Bright Nickel QQ-N-290 QQ-N-290 Tin Lead Tin Lead Tin Lead Silver ASTM-B-545 ASTM-B-545 Gold ASTM-B-545 QQ-S-365 Gold Silver, QQ-S-365 Silver, QQ-S-365 MIL-B-45204 Silver, QQ-S-365 Gold Gold, MIL-G-45204 Gold, MIL-G-45204 Gold, MIL-G-45204 MIL-G-45204 — Several pc board connectors have an outer polyester PBT insulator per MIL-P-24519. If more than one finish is listed, refer to individual catalog page(s) or customer drawings for exact specification. Ferrules with tin-lead finish are used with nickel plated outer contacts. 1 2 3 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 43 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm Plugs, Crimp Single Crimp Hex and O Crimp L Max. 14.53 [.572] Dia. Max. 14.53 [.572] Dia. Max. Style Dim. L CERTI-CRIMP Hand Tool with Integral Die Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. Head 318161-1 Part No. TEFLON Mil Type 33.33 1.312 69245-4 — 269471-1 2330876-0 Nickel Polyethylene Commercial — 358436-3 — 2-221128-1 Gold Nickel Polyethylene Commercial 220009-5 318450-2 220217-3 1-227079-6 O Crimp Gold Nickel Polyethylene Economy — 58559-1 — 414852-3 O Crimp Gold Nickel Polyethylene Economy — — — 414915-35 O Crimp Gold Nickel TEFLON Mil Type 220009-1 — 220026-1 225395-7 O Crimp Gold Silver TEFLON Mil Type 220009-1 — 220026-1 2-331350-4 Single Crimp Gold Silver TEFLON Mil Type 69245-2 — 269422 2-330061-1 Hex Crimp Gold Nickel Polyethylene Commercial — 358436-3 — 2-221128-3 O Crimp Gold Nickel Polyethylene Commercial 220009-5 318450-2 220217-3 2-227079-2 O Crimp Gold Nickel TEFLON Mil Type 220009-1 — 220026-1 225395-8 O Crimp Gold Silver TEFLON Mil Type 220009-1 — 220026-1 2-331350-5 69245-1 — 269408 2-329446-1 69477-4 358539-1 — 8-227079-2 69477-2 — 269669-2 5-225395-7 — 158436-3 — 2-221128-5 69477-2 — 269669-2 — 158436-1 220187-1 RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric 178, 178A, 178B, 196, 196A Single Crimp Gold Silver Hex Crimp Gold O Crimp Single Crimp Gold Silver TEFLON Mil Type RD 316, 188, Double Braid Belden 9252, 122 O Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel TEFLON Mil Type 180, 180A, C1180B, 195, 195A Hex Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel TEFLON Mil Type Hex Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel Polyethylene Commercial 33.53 1.320 27.69 1.090 27.69 1.090 27.69 1.090 30.18 1.188 30.18 1.188 33.33 1.312 33.53 1.320 27.69 1.090 -30.18 1.188 30.18 1.188 33.33 1.312 27.69 1.090 38.10 1.500 33.53 1.320 35.44 1.395 33.53 1.320 27.69 1.090 O Crimp Gold Nickel Polyethylene Commercial 27.69 1.090 O Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel TEFLON Mil Type 27.69 1.090 30.18 1.188 174, 188, 188A, 316 179, 179A, 179B, 161, 187, 187A, Belden 9221 Belden 8219 Belden 9907, 89907 Comm/ Scope 2104 Belden 8218 L Max. 225395-9 — 2-221128-7 158435-11 220217-1 6-227079-73 220187-1 318452-2 220217-1 6-227079-84 69477-4 158539-1 258376-1 1-227079-9 69477-2 — 269669-2 1-225395-0 2 Order AMP PRO-CRIMPER Coaxial “O” Crimp Hand Tool assembly 58433-1, which includes dies 58435-1. Order AMP PRO-CRIMPER Coaxial Hex Crimp Hand Tool assembly 58433-2, which includes dies 58436-1. For use with Belden 9907, Comm/Scope 3104, Belden 8219 only. 4 For use with Belden 89907, Comm/Scope 2104 only. 5 Kit includes connector subassembly and ferrule only, center contact part no. 1-414724-0 supplied separately on strip. Terminate with Amp-o-lectric terminating machine 220152-1 with applicator. 1 2 3 44 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Plugs, Crimp (Continued) Single Crimp Hex and O Crimp L Max. 14.53 [.572] Dia. Max. RG/U Cable 58, 58A, 58B, 58C Termination Type Center Contact Plating Body Plating Dielectric Style Hex Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel Polyethylene Commercial O Crimp Silver Nickel Polyethylene Commercial O Crimp Gold Nickel Polyethylene Economy O Crimp Gold Nickel Polyethylene Economy O Crimp Gold Nickel TEFLON Mil Type O Crimp Gold Silver TEFLON Mil Type Single Crimp Gold Silver TEFLON Mil Type 141, 141A, 303 O Crimp Gold Nickel TEFLON Mil Type Belden 88240, Berk-Tek BTDC-58, Comm/ Scope 2135 Hex Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel Polyethylene Commercial 223, 55, 55A, 55B O Crimp Gold Nickel TEFLON Mil Type O Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel TEFLON Mil Type Single Crimp Gold Silver TEFLON Mil Type O Crimp 142, 142A, 142B, 400 O Crimp Gold Gold Nickel Nickel Polyethylene TEFLON Commercial Mil Type O Crimp Gold Silver TEFLON Mil Type Single Crimp Gold Silver TEFLON Mil Type 14.53 [.572] Dia. Max. Dim. L 33.53 1.320 27.69 1.090 27.69 -1.090 27.69 1.090 27.69 1.090 33.74 1.328 33.74 1.328 33.33 1.312 30.18 1.188 33.53 1.320 33.33 1.312 33.33 1.312 27.69 1.280 43.64 1.718 33.33 1.312 27.69 1.090 30.18 1.188 30.18 1.188 33.33 1.312 L Max. CERTI-CRIMP Hand Tool with Integral Die Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 — 158436-12 — 221128-13 220187-1 158435-11 220217-1 227079-5 220187-1 158435-11 220217-1 227079-9 58558-1 — 414852-1 — — — 414915-14,5 269478-1 220189-3 269727-1 225395-1 269478-1 220189-3 269727-1 2-331350-1 269140-1 — 269223-1 2-329444-1 269478-1 220189-3 269727- 225395-5 — 158436-12 — 1-221128-0 220187-1 158435-11 220217-1 4-227079-3 269478-1 220189-3 269727 4-225395-2 220187-1 158435-1 220217-1 227079-6 269478-1 220189-3 269727- -225395-3 269140-2 — 269424 2-329444-2 220187-1 258435-11 220217-1 6-227079-1 -225395-6 — 269478-1 Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. 1 1 Part No. Head 318161-1 220189-3 269727 269478-1 220189-3 269727- 2-331350-9 269331-1 — 269429-1 2-330358-2 Consult AMP for recommended crimp tooling. 1 Order AMP PRO-CRIMPER Coaxial “O” Crimp Hand Tool assembly 58433-1, which includes dies 58435-1. 2 Order AMP PRO-CRIMPER Coaxial Hex Crimp Hand Tool assembly 58433-2, which includes dies 58436-1. 3 Bulk packaged. 4 Kit includes connector subassembly and ferrule only, center contact part no. 414724-2 supplied separately on strip. 5 Terminate with Amp-o-lectric terminating machine 220152-1 with applicator. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 45 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Plugs, Crimp (Continued) Single Crimp Hex and O Crimp L Max. 14.53 [.572] Dia. Max. RG/U Cable 124, 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269 302, Belden 88241, 89269, Hi-Temp 62A, Times PL62, Berk-Tek, BTDC-59, BTDC-62 Hi-Temp 59, Times PL59, PLF59 (20 AWG C.C.) Belden 9104, 9240, 9112, 9167, 9259, 9266, Times FM-59 Belden 9248, 9114 Termination Type Center Contact Plating Body Plating Dielectric Style Dim. L Hex Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Silver TEFLON Mil Type Single Crimp Gold Silver TEFLON Mil Type Hex Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel TEFLON Mil Type 33.53 1.320 27.69 1.090 27.69 1.090 27.69 1.090 27.69 1.090 30.18 1.188 30.18 1.188 33.33 1.312 33.53 1.320 33.33 1.312 34.14 1.344 O Crimp Gold Nickel Polyethylene Commercial Hex Crimp Gold Nickel Polyethylene Commercial O Crimp Gold Nickel Polyethylene Commercial O Crimp Silver Nickel Polyethylene Commercial O Crimp Gold Nickel Polyethylene Economy O Crimp Gold Nickel Polyethylene Economy O Crimp Gold Nickel TEFLON Mil Type O Crimp O Crimp O Crimp Hex Crimp Belden 8281, 9141, 9231, Western Electric 724, 728, 3049 14.53 [.572] Dia. Max. O Crimp Gold Gold Gold Gold Gold Nickel Nickel Nickel Nickel Nickel Polyethylene TEFLON Polyethylene Polyethylene Polyethylene Commercial Mil Type Commercial Commercial Commercial O Crimp Gold Silver TEFLON Mil Type Single Crimp Gold Silver Polypropylene Mil Type 8, 8A, 213 O Crimp Gold Silver TEFLON Mil Type 11, 11A O Crimp Gold Silver TEFLON Mil Type Belden 9914, Times FM-8 Alpha 9847, Belden 8213, 9292 9, 9A, 9B, 214 O Crimp Gold Silver TEFLON Mil Type O Crimp Gold Silver TEFLON Mil Type O Crimp Gold Silver TEFLON Mil Type L Max. Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. Head 318161-1 Part No. — Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 258436-12 — 1-221128-1 220187-2 258435-11 220217-2 227079-7 220187-2 258435-11 220217-2 1-227079-1 58558-1 — 414852-2 — — 414915-2 3,4 CERTI-CRIMP Hand Tool with Integral Die — 2 — 269477-1 58537-1 — 225395-2 269477-1 — 269669-1 331350-0 269141-1 — — 220187-2 2 — 2-329445-1 2 258436-1 — 1-221128-1 258435-1 1 220217-2 4-227079-9 58537-1 269669-1 4-225395-1 58537-1 — 5-227079-3 258436-12 — 1-221128-7 — 1-227079-3 269669-1 2-225395-0 — 3-227079-0 — 1-221128-2 220088-1 5-227079-8 269477-1 2 33.33 1.312 — 2 33.53 1.320 27.69 1.090 30.94 1.218 27.69 1.090 33.53 1.320 31.75 1.250 38.10 1.500 41.50 1.634 27.31 1.075 47.63 1.875 47.63 1.875 47.63 1.875 52.38 2.062 — 2 220187-2 58537-1 2 269477-1 58537-1 2 220247-1 58539-1 2 — 58436-2 2 220043-1 58538-1 2 220043-1 58538-1 220088-1 4-331350-0 69652- — 220000- 330878-0 220015-1 — — -225886-1 220015-1 — — 225886-4 220015-1 — — 225886-7 220015-1 — — 225886-5 220015-1 — — 225886-1 Order AMP PRO-CRIMPER Coaxial “O” Crimp Hand Tool assembly 58433-1, which includes dies 58435-1. Order AMP PRO-CRIMPER Coaxial Hex Crimp Hand Tool assembly 58433-2, which includes dies 58436-1. AMP PRO-CRIMPER II Hand Tool Frame without dies Part No. 354940-1 3 Kit includes connector sub assembly and ferrule only, center contact part no. 414724-4 supplied separately on strip. 4 Terminate with Amp-o-lectric terminating machine 220152-1 with applicator. 1 2 2 46 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Plugs, Solder/Clamp Standard Push-On H 14.3 [.563] 13.67 [.538] Ref. L Max. L Max. H = 12.7 [.500] Max. across flats, 14.74 [.580] Max. across points. 9.65-9.78 [.380/.385] Dia. RG/U Cable RG174A/U, RG188A/U, RG316/U, URM95 RG179B/U, RG187A/U, URM111 Center Contact Plating Body Plating Dielectric Style M/A-COM Model No. Dim. L Part No. Gold Silver TEFLON Mil Type B35A70E022X 1310700-1 Gold Nickel TEFLON Mil Type B35A70J022X Gold Silver TEFLON Mil Type B37A70E022X Gold Silver TEFLON Mil Type B35A70E010X 28.5 1.122 28.5 1.122 28.5 1.122 28.5 1.122 28.5 1.122 26.04 1.025 28.5 1.122 28.5 1.122 28.5 1.122 28.5 1.122 38.1 1.500 38.1 1.500 28.5 1.122 28.5 1.122 28.5 1.122 Maximum PC Board Thickness 2.11 [.083] RG58C/U, RG141A/U, URM43, URM76 Recommended Panel Cutout for Push-On Style Gold Nickel TEFLON Mil Type B35A70J010X 58, 58A, 58B, 58C Gold Nickel TEFLON Push-On — RG55B/U, RG142B/U, RG223/U, RG400/U, URM301 Gold Silver TEFLON Mil Type B35A70E060X Gold Nickel TEFLON Mil Type B35A70J060X Gold Silver TEFLON Mil Type B37A70E025X Gold Nickel TEFLON Mil Type B37A70J025X Gold Silver TEFLON Mil Type B35A03E001X Gold Nickel TEFLON Mil Type B35A03J001X RG59B/U, RG62A/U, RG140/U, TM3304 PSF1/4(BBC), RG8A/U, RG213/U, URM67 URM70 Gold Silver TEFLON Mil Type B37A70E012X BT2003, BT2003A Gold Silver TEFLON Mil Type B37A70E062X BT2002 Gold Silver TEFLON Mil Type B37A70E117X 1310705-1 1311685-1 1310697-1 1310702-1 222728-1 1312559-1 1311674-1 1310776-1 1310777-1 1314882-1 1310690-1 1310775-1 1314874-1 1314875-1 Plugs, Twist-On Related Product Data Twist-On plugs must be used with cable that has a solid conductor. These plugs are not recommended for applications where the cable frequently moves or flexes. Mating Twist-On Jack — Page 51 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 14.53 [.572] Dia. Max. RG/U Cable 58, 58B 59, 59A, 59B Belden 8281, 9141, 9231, Western Electric 724, 728, 3049 38.10 [1.500] Contact Plating Body Plating Dielectric Style Part No. Gold Nickel Commercial 414265-7 Gold Nickel Polymethylpentene Polymethylpentene Commercial 414265-3 Gold Nickel Polymethylpentene Commercial 414265-5 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 47 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Right Angle Plugs, Crimp Single Crimp Hex and O Crimp 26.57 [1.046] 26.57 [1.046] L Max. L Max. 14.53 [.572] Dia. Max. RG/U Cable Body Plating Dielectric Style Dim. L Hex Crimp Gold Nickel Polymethylpentene Commercial — 258436-3 — 413959-3 269245-1 — 269422 331178-0 — 258436-3 — 413959-4 Single Crimp Gold Silver TEFLON Mil Type Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 1.553 RD 316 Hex Crimp Gold Nickel — — 58, 58A, 58B, 58C 55, 55A, 55B, 223 142, 142A, 142B, 400 124, 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269 Interchangeable Dies for PRO-CRIMPER Interchangeable Hand Tool 354940-1 Dies for Hand or Tool 69710-1 PRO-CRIMPER & 626 Pneu. Adapter 679304-1 Head 318161-1 Termination Type 179, 179A, 179B, 161, 187, 187A, Belden 9221 180, 180A, 180B, 195, 195A Belden 9907, 89907, 8219, Comm/Scope 2104, 3104 CERTI-CRIMP Hand Tool with Integral Die Center Contact Plating 39.45 1.553 44.45 1.750 174, 188, 188A, 316 48 14.53 [.572] Dia. Max. Part No. — — 220026-1 413959-7 Commercial 39.45 1.553 39.45 1.553 — 258436-3 — 413959-5 Hex Crimp Gold Nickel Polymethylpentene Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 1.553 — 258436-1 — 413959-6 Hex Crimp Gold Nickel Polymethylpentene Commercial — 258436-1 — 413959-1 O Crimp Gold Nickel TEFLON Mil Type 269478-1 220189-3 269727-1 225974-1 Single Crimp Gold Silver TEFLON Mil Type 269140-1 — 269223-1 331175-0 O Crimp Gold Nickel TEFLON Mil Type 269478-1 220189-3 269727-1 225974-2 Single Crimp Gold Silver TEFLON Mil Type 269140-2 — 269429-1 331182-0 O Crimp Gold Silver TEFLON Mil Type 269478-1 220189-3 269727-1 225973-4 Single Crimp Gold Silver TEFLON Mil Type 39.45 1.553 37.29 1.468 44.45 1.750 37.29 1.468 44.45 1.750 37.29 1.468 44.45 1.750 269331-1 — 269429-1 331182-0 Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 1.553 — 258436-1 — 413959-2 O Crimp Gold Nickel TEFLON Mil Type 37.29 1.468 269477-1 258537-1 269669-1 225974-5 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Right Angle Plugs, Solder/Clamp 29.2 [1.150] 14.3 Dia. [.563] Max. 28.0 [1.102] Part No. 1310707-1 RG/U Center Contact Cable Plating RG174A/U, RG188A/U, Gold RG316U, URM95 Gold RG58C/U, RG141A/U, URM43, URM76 Gold RG59B/U, RG62A/U, Gold RG140/U URM70 Gold Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Body Plating Dielectric Style M/A-COM Model No. Part No. Silver TEFLON Mil Type B35B02E022X 1328427-1 Silver Nickel TEFLON TEFLON Mil Type Mil Type B35B02E010X B35B02J010X 1310707-1 1310712-1 Silver TEFLON Mil Type B37B02E025X 1328481-1 Silver TEFLON Mil Type B37B02E012X 1310778-1 www.amp.com/communications/com Specifications subject to change. 49 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Jacks, Crimp Single Crimp 11.1 [.437] Dia. Max. RG/U Cable 174, 188, 188A, 316 179, 179A, 179B, 161, 187, 187A, Belden 9221 180, 180A, 180B, 195, 195A Belden 89907, 9907, 8219, Comm/Scope 3104, 2104 58, 58A, 58B, 58C 58, 58A, 58B, 58C Belden 88240, BerkTek BTDC-58 Comm/Scope 2135 223, 55, 55A, 55B 124, 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269 Termination Type Center Contact Plating Body Plating Hex and O Crimp 11.08 [.436] Dia. Max. L Max. Dielectric Style Hex Crimp Gold Nickel O Crimp Gold Nickel Polymethylpentene Polypropylene O Crimp Gold Nickel TEFLON Mil Type Single Crimp Gold Silver TEFLON Mil Type Commercial Commercial Commercial Dim. L 33.02 1.300 30.48 1.200 30.48 -1.200 33.33 1.312 -33.02 1.300 30.48 1.200 L Max. CERTI-CRIMP Hand Tool with Integral Die Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 — 258436-3 — 413779-3 220009-5 — 220217-3 228979-7 220009-1 — 220026-1 225396-7 69245-2 — 69422 2-330062-1-1 — 258436-3 — 413779-4 220009-1 — 220026-1 225396-8 Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. Part No. Head 318161-1 Hex Crimp Gold Nickel Polymethylpentene O Crimp Gold Nickel TEFLON Mil Type Hex Crimp Gold Nickel Polymethylpentene Commercial 33.02 1.300 — 258436-3 — 413779-5 Hex Crimp Gold Nickel Polymethylpentene Commercial 33.02 1.300 — 258436-1 — 413779-6 O Crimp Gold Nickel Polypropylene Commercial 220187-1 258435-11 220217-1 228979-5 269478-1 220189-3 269727- 225396-11 269478-1 220189-3 269727-1 2-331351-1 269140-1 — 269223-1 2-329545-1 Single Crimp Gold Silver TEFLON Mil Type 30.48 1.200 30.48 1.200 30.48 1.200 33.33 1.312 Hex Crimp Gold Nickel Polymethylpentene Commercial 33.02 1.300 — 258436-1 — 413779-1 Single Crimp Gold Silver TEFLON Mil Type 269140-2 — 269424- 2-329452-21 Polymethylpentene Polypropylene Commercial 33.33 1.312 33.02 1.300 30.48 1.200 30.48 1.200 30.48 1.200 33.33 1.312 — 258436-1 — 413779-2 220187-2 258435-11 220217-2 -228979-6 269477-1 258537-1 269669-1 225396-2 269477-1 — 269669-1 331351 269141-1 — 269224-1 2-329549-1 O Crimp O Crimp Gold Gold Nickel Silver Hex Crimp Gold Nickel O Crimp Gold Nickel O Crimp Gold Nickel O Crimp Single Crimp Gold Gold Silver Silver TEFLON TEFLON TEFLON TEFLON TEFLON Mil Type Mil Type Commercial Mil Type Mil Type Mil Type Order AMP PRO-CRIMPER Coaxial “O” Crimp Hand Tool assembly 58433-1, which includes dies 58435-1. 1 50 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Jacks, Solder/Clamp 14.3 Dia. [.563] RG/U Cable RG58C/U, RG141A/U, URM43, URM76 33.3 Dia. [1.311] Max. Center Contact Plating Body Plating Dielectric Style M/A-COM Model No. Part No. Gold Silver TEFLON Mil Type B35E60E010X 1327037-1 Gold Nickel TEFLON Mil Type B35E60J010X 1310970-1 Jacks, Twist-On Related Product Data Twist-on jacks must be used with cable that has a solid conductor. These jacks are not recommended for applications where the cable frequently moves or flexes. 40.14 Max. [1.580] Mating Twist-On Plug — Page 47 RG/U Cable 58,58B 59, 59A, 59B Center Contact Gold Gold Body Plating Nickel Nickel Dielectric Style Part No. Acetal Acetal Commercial Commercial 222428-7 222428-1 Panel Jacks, Crimp 11.2 [.441] Dia. 12.7 ±0.1 [.500 ±.004] 17.84 Max. [.702] 12.7 ±0.1 [.500 ±.004] 28.96 [1.140] Max. 2.77 Dia. [.109] Recommended Panel Cutout RG/U Cable Termination Type Center Contact Plating 174, 188, 188A, 316 RD 316, 188 58, 58A, 58B, 58C 124, 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269, 89269 O Crimp O Crimp O Crimp Gold Gold Gold Nickel Nickel Nickel TEFLON TEFLON TEFLON Mil Type Mil Type Mil Type 220009-1 220009-1 -69478-1 Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 — — 220189-3 O Crimp Gold Nickel TEFLON Mil Type -69477-1 258537-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Body Plating Dielectric Style CERTI-CRIMP Hand Tool with Integral Die Dimensions are in millimeters over [inches] www.amp.com/communications/com Interchangeable Dies for Hand Tool 69710-1 Part No. & 626 Pneu. Head 318161-1 220026-1 220026-1 69727- 225397-7 1-225397-4 225397-1 269669-1 225397-2 Specifications subject to change. 51 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Bulkhead Jacks, Crimp Single Crimp Hex and O Crimp Note: Panel Insulating Bushings — Page 54 H H L Max. L Max. +0.13 12.83 -0.00 Dia. [.505 +.005 ] 12.82 [.505] Dia. Min. Recommended Panel Cutouts -.000 11.04 [.435] Min. Maximum Panel Thickness 3.18 [.125] +0.08 5.54 -0.00 [.218 +.003 ] -.000 H = 11/16" across flats, 20.32 [.800] Max. across points Dielectric Style Dim. L Interchangeable Dies for PRO-CRIMPER Interchangeable Hand Tool 354940-1 Dies for Hand Part No. or Tool 69710-1 PRO-CRIMPER & 626 Pneu. Adapter 679304-1 Head 318161-1 RG/U Cable Termination Type 178, 178A, 178B, 196, 196A Single Crimp Gold Silver TEFLON Mil Type 32.13 1.265 2 69245-4 — 269471- Hex Crimp Gold Nickel Commercial — 58436-3 — 413771-3 O Crimp Gold Nickel Polymethylpentene Polypropylene 220009-5 — 220217-3 228980-7 O Crimp Gold Nickel TEFLON Mil Type 220009-1 — 220026-1 225398-7 O Crimp Gold Silver TEFLON Mil Type 220009-1 — 220026-1 1-331693-2 Single Crimp Gold Silver TEFLON Mil Type 269245-2 — 269422- 2-330063-1 Commercial — 58436-3 — 413771-4 Mil Type 220009-1 — 220026-1 225398-8 269245-1 — 269408- 2-329458-1 269477-2 — 269669-2 1-225398-5 174, 188, 188A, 316 179, 179A, 179B, 161, 187, 187A, Belden 9221 Times RD316 180, 180A, 180B, 195, 195A Belden 9907, 89907, 8219, Comm/Scope 2104, 3104 52 Body Plating CERTI-CRIMP Hand Tool with Integral Die Center Contact Plating 331974 Single Crimp Gold Silver TEFLON Mil Type O Crimp Gold Nickel TEFLON Mil Type 36.83 1.450 34.93 1.375 35.71 1.406 35.71 1.406 32.13 1.265 36.83 1.450 35.71 1.406 32.13 1.265 35.71 1.406 Hex Crimp Gold Nickel Polymethylpentene Commercial 36.83 1.450 — 58436-3 — 413771-5 Hex Crimp Gold Nickel Polymethylpentene Commercial 36.83 1.450 — 58436-1 — 413771-6 Hex Crimp Gold Nickel Polymethylpentene O Crimp Gold Nickel TEFLON Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Commercial Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Bulkhead Jacks, Crimp (Continued) Single Crimp Hex and O Crimp Note: Panel Insulating Bushings — Page 54 L Max. H H L Max. +0.13 12.83 -0.00 Dia. [.505 +.005 ] 12.82 [.505] Dia. Min. Recommended Panel Cutouts -.000 11.04 [.435] Min. Maximum Panel Thickness 3.18 [.125] +0.08 5.54 -0.00 [.218 +.003 ] -.000 H = 11/16" across flats, 20.32 [.800] Max. across points Style CERTI-CRIMP Hand Tool with Integral Die Polymethylpentene Commercial 36.83 1.450 — 258436-1 — 413771-1 Nickel Polypropylene Commercial 220187-1 0158435-11 220217-1 228980-5 Gold Nickel TEFLON Mil Type 269478-1 220189-3 269727-1 225398-1 Gold Silver TEFLON Mil Type 34.93 1.375 41.28 1.625 32.13 1.265 35.71 1.406 35.71 1.406 36.83 1.450 1-34.93 1.375 41.28 1.625 269140-1 — 269223-1 2-329456-1 220189-3 269727- 225398-3 — 220189-3 269727-1 225398-6 — 058436-1 — 413771-2 220187-2 0158435-11 220217-2 228980-6 269477-1 058537-1 269669-1 225398-2 Termination Type Center Contact Plating Body Plating Dielectric 58, 58A, 58B, 58C, Belden 88240, BerkTek BTDC58, Comm/ Scope 2135 Hex Crimp Gold Nickel O Crimp Gold O Crimp Single Crimp 58, 58A, 58B, 58C 223, 55, 55A, 55B 142, 142A, 142B, 400 O Crimp O Crimp Gold Nickel TEFLON Mil Type 124, 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269 Hex Crimp Gold Nickel Polymethylpentene Polypropylene Commercial O Crimp O Crimp Interchangeable Dies Interchangeable for PRO-CRIMPER Dies for Hand Hand Tool 354940-1 Tool 69710-1 or & 626 Pneu. PRO-CRIMPER Head 318161-1 Adapter 679304-1 Dim. L RG/U Cable Gold Gold Gold Nickel Nickel Nickel TEFLON TEFLON Mil Type Commercial Mil Type 269478-1 Part No. Order AMP PRO-CRIMPER Coaxial “O” Crimp Hand Tool assembly 58433-1, which includes dies 58435-1. 1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 53 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Bulkhead Jacks, Solder/Clamp 12.9 Dia. [.508] Note: Panel Insulating Bushings — See below. 5.56 [.219] H 31.6 Dia. [1.244] Max. Recommended Panel Cutout Maximum Panel Thickness 3.6 [.142] H = 17.5 [.689] across flats, 20.32 [.800] Max. across points Panel Insulating Bushings for Bulkhead Jacks RG/U Cable Center Contact Plating Body Plating Dielectric Style M/A-COM Model No. Part No. RG179B/U, RG187A/U, URM111 RG58C/U, RG141A/U, URM43, URM76 RG59B/U, RG62A/U, RG140/U URM70 Gold Silver TEFLON Mil Type B37H39E022X 1310793-1 Gold Silver TEFLON Mil Type B35H39E010X 1314101-1 Gold Nickel TEFLON Mil Type B37H39J025X 1311691-1 Gold Silver TEFLON Mil Type B37H39E012X 1310792-1 0.89 [.035] 12.93 [.509] Dia. 0.81 [.032] 5.46 [.215] 13.95 [.549] Dia. 14.73±0.13 [.580±.005] Dia. Material — Nylon Note: Can not be used with single crimp bulkhead jacks. 14.1±0.08 [.555±.003] 17.45 [.687] Dia. 14.58 Dia. [.574] Recommended Panel Cutout Part No. 330620 (2 Required) 54 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Polarized Connectors, Crimp 14.53 Max. [.572] 29.03 Max. [1.143] 27.69 Max. [1.090] Description RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric Style Dim. L Plug 58, 58A 58B, 58C 58, 58A 58B, 58C O Crimp O Crimp Gold Nickel TEFLON Commercial Gold Nickel TEFLON Commercial 27.69 1.090 29.03 1.143 Jack CERTI-CRIMP Hand Tool with Integral Die Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. Head 318161-1 Part No. 220187-1 220189-1 220217-1 415087-1 220187-1 220189-1 220217-1 415407-1 Insulated Plugs, Crimp 53.0 [2.086] Assembled 17.1 Dia. [.673] RG/U Cable Center Contact Plating Body Plating Dielectric Style M/A-COM Model No. Part No. Belden 9907, RG58C/U Gold Nickel TEFLON Mil Type B35A04JB105 1310693-1 Plugs, for JIS Cables, Crimp Plating Body — Nickel Center Contact — Gold 14.53 [.572] Dia. Max. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 L Max. JIS Cable Termination Type Dielectric Dim. L 3D-2V Hex Crimp Polyethylene 1.5D-2V Hex Crimp Polyethylene 33.53 1.320 33.53 1.320 Dimensions are in millimeters over [inches] Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Part No. 58436-1 3-221128-1 58436-3 3-221128-2 www.amp.com/communications/com Specifications subject to change. 55 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Bulkhead Solder Jacks, Front Mount Without Solder Terminal With Solder Terminal Body Plating — Nickel 22.23 [.875] 9.65/9.75 [.380/.384] Dia. Accepts 1.5 [.059] Dia. Max. Wire 3/8" - 32 Thread Accepts 1.5 [.059] Dia. Max. Wire 3/8" - 32 Thread .396/4.04 [.156/.159] L Max. W Dia. Max. Recommended Panel Cutout Contact Material Dielectric Silver VALOX Dimensions L W 26.93 1.060 33.33 1.312 26.93 1.060 33.33 1.312 26.93 1.060 33.33 1.312 26.93 1.060 VALOX Gold TEFLON Tin Lead VALOX L Max. W Dia. Max. 13.09 .515 13.09 .515 13.09 .515 13.09 .515 13.09 .515 13.09 .515 13.09 .515 Panel Thickness Insulating Bushing 1.17-3.18 .046-.125 1.17-6.35 .046-.250 1.17-3.18 .046-.125 1.17-6.35 .046-.250 1.17-3.18 .046-.125 1.17-6.35 .046-.250 1.17-3.18 .046-.125 227223-1 or 221951-1 227223-1 or 221951-1 227223-1 or 221951-1 227223-1 or 221951-1 227223-1 or 221951-1 227223-1 or 221951-1 227223-1 or 221951-1 Part No. Without Solder With Solder Terminal* Terminal** 227754-3 227755-3 227169-3 227169-7 227754-2 227755-2 227169-4 227169-8 227715-3 227716-3 227169-1 227169-5 227754-1 227755-1 **Includes lockwasher and jam nut. **Includes solder terminal and jam nut. Insulating Bushings 1.09 Max. [.043] 11.43 [.450] 4.04 Max. [.159] 0.94 [.030] Max. 14.86 Dia. [.585] 10.93 Dia. [.430] 1.78 [.070] 12.7 [.500] Dia. 0.81 [.032] 11.94 [.470] 9.53 Dia. [.375] 15.88 Dia. [.625] 9.53 [.375] Part No. 227223-1 Part No. 221951-1 Recommended Panel Cutout Recommended Panel Cutout 11.56 ±0.08 [.455 ±.003] Dia. 12.83 ±0.08 [.505 ±.003] Dia. 10.97 ±0.06 [.432 ±.003] 56 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 3.94 Dia. [.155] Dimensions are in millimeters over [inches] 12.07±0.08 [.475 ±.003] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) 3/8" - 24 Thread Isolated Bulkhead Solder Jacks, Front Mount Accepts 1.5 [.059] DIa. Max. Wire Plating Body — Nickel Dielectric — White VALOX Center Contact Plating Tin Silver Gold Flange & Thread Material VALOX VALOX VALOX Part No. +0.13 9.91 -0.20 Dia. [.390 +.005 ] -.000 +0.08 31.75 Max. [1.250] 13.09 Dia. [.515] Max. 3.89 -0.00 [.153 +.003 ] -.000 Panel Thickness 1.17-6.35 [.046-.250] 227726-1 227726-2 227726-3 Recommended Panel Cutout 3/8" - 24 Thread Plating Body — Nickel Center Contact — Silver Dielectric — Black VALOX Flange & Thread Material — Black VALOX +0.08 9.60 -0.00 Dia. [.378 +.003 ] -.000 12.83 [.505] Max. +0.08 3.94 -0.00 [.155 +.003 ] 26.80 [1.055] Max. -.000 Panel Thickness 1.17-3.18 [.046-.125] Recommended Panel Cutout Part No. 414194-1 Rubber Gasket Sealed Bulkhead Solder Jack, Rear Mount Plating Body — Nickel Center Contact — Gold Dielectric — Polymethylpentene This connector is designed to prevent moisture from entering the interface from the rear of the connector. +0.13 17.78 Dia. [.700] Max. 1/2" - 28 Thread 12.83 -0.00 Dia. [.505 +.005 ] -.000 Accepts . 1.5 [.059] DIa. Max. Wire +0.08 5.54 -0.00 [.218 +.003 ] 31.75 [1.250] Max. -.000 Maximum Panel Thickness 6.35 [.250] Recommended Panel Cutout Part No. 227426-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 57 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Right-Angle Jacks PC Board/Panel Mount VALOX Body Metal Body 1/2-28 Thread 1/2-28 Thread C Mtg. Hgt. Body — Nickel Dielectric — Polymethylpentene C L A C Mtg. Hgt. C L B A B 34.93 [1.375] 34.93 [1.375] Mounting Post Style Center Contact Plating Body Material Tin-Lead L Gold1 VALOX, White Gold2 Tin-Lead Gold1 Compliant Post Tin-Lead Gold1 VALOX, Black Gold1 L E Gold1 Tin-Lead Gold1 +0.13 12.83 -0.00 Dia. [.505 +.005 ] Metal -.000 Gold1 Gold2 High Temp. Housing +0.08 5.54 -0.00 Dia. [.218 +.003 ] -.000 Maximum Panel Thickness 6.1 [.240] Recommended Panel Cutout Gold1 A B C 8.59 .338 8.59 .338 8.59 .338 6.91 .272 6.91 .272 8.59 .338 8.59 .338 6.91 .272 6.17 .243 8.26 .325 8.26 .325 6.91 .272 6.91 .272 6.91 .272 21.21 .835 21.21 .835 21.21 .835 21.21 .835 21.21 .835 21.21 .835 21.21 .835 21.21 .835 21.21 .835 20.83 .820 20.83 .820 20.83 .820 20.83 .820 21.21 .835 15.88 .625 15.88 .625 15.88 .625 13.18 .519 13.18 .519 15.88 .625 15.88 .625 13.18 .519 11.68 .460 15.88 .625 15.88 .625 12.70 .500 12.70 .500 13.18 .519 With Compliant Posts L — — — — — — — — — 414684-1 4.70 1.85 — — — 1-227161-4* 226990-7 — — — 1-227161-7* 226990-2 1-227161-2* 226990-6 1-227161-6* 3.48 .137 3.48 .137 3.48 .137 3.48 .137 — — 415218-1 2.79 .110 — 1-227161-9* — 1-415046-1* — 415046-2 — 227433-1 1-227661-1* — — 227676-1 222785-1 3.89 .153 — 1-227677-1 * 1-227677-2* 1-413879-1* — — — 1-413879-2* 3.48 .137 3.48 .137 3.48 .137 3.48 .137 — — — — 415218-5 — — *IR reflow compatible Plating: Gold1 — 0.00076 [.000030] thick Gold2 — 0.00127 [.000050] thick Note: If an Insulating Bushing is required see part number 330620 and Panel Cutout on page 54. Lockwasher and Jam Nut Without Mounting Posts 10.16 ±0.08 [.400 ±.003] With Mounting Posts 2.64 [.104] Dia. Clearance Hole for 2-56 Self-Tapping Screw* (2 Holes) 5.08 ±0.05 [.200 ±.002] 5.08 ±0.05 [.200 ±.002] G Part No. 1-329632-2 Part No. Without With L Mounting Posts Mounting Posts 3.48 226990-1 1-227161-1* .137 3.48 226990-3 1-227161-3* .137 Dimensions Part No. 1-329631-2 2.54 ±0.05 [.100 ±.002] S 10.16 ±0.08 [.400 ±.003] 5.08 ±0.05 [.200 ±.002] 5.08 ±0.05 Mating [.200 ±.002] Face Mating Face G 0.89 ±0.08 [.035 ±.003] 2.54 ±0.05 [.100 ±.002] (Top View) 2.01 ±0.05 [.079 ±.002] (2 Holes) S 0.89 ±0.08 [.035 ±.003] (Top View) Recommended PC Board Layouts * Screw for panel thickness of 2.38 [3/32] or greater Part No. 221108-2. Screw for panel thickness of less than 2.38 [3/32] Part No. 221108-4. 58 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Vertical Jacks PC Board/Panel Mount VALOX Body Metal Body L L Plating Body — Nickel Dielectric — Polymethylpentene 1/2-28 Thread 1/2-28 Thread B +0.13 12.83 -0.00 Dia. [.505 +.005 ] -.000 Body Material +0.08 5.54 -0.00 Dia. [.218 +.003 ] -.000 Maximum Panel Thickness 6.1 [.240] VALOX, White Recommended Panel Cutout VALOX, Black B 34.93 [1.375] Mtg. Hgt. Center Contact Plating Dim. B Dim. L Tin-Lead 21.21 .835 21.21 .835 21.21 .835 21.21 .835 20.83 .820 20.83 .820 3.48 .137 3.48 .137 3.48 .137 3.48 .137 3.48 .137 3.48 .137 Gold Tin-Lead Gold Tin-Lead Lockwasher and Jam Nut 15.88 [.625] 15.88 [.625] Metal Gold 34.93 [1.375] Mtg. Hgt. Part No. Without With Mounting Mounting Posts Posts 226993-1 227222-1 226993-3 227222-3 226993-2 227222-2 226993-6 227222-6 227670-1 227671-1 227672-1 227673-1 Note: If an Insulating Bushing is required see part number 330620 and Panel Cutout on page 54. Part No. 1-329632-2 Part No. 1-329631-2 Without Mounting Posts With Mounting Posts 2.64 [.104] Dia. Clearance Hole for 2-56 Self-Tapping Screw* (2 Holes) 5.08 ±0.05 [.200 ±.002] 2.54 ±0.05 [.100 ±.002] 10.16 ±0.08 [.400 ±.003] G S 10.16 ±0.08 [.400 ±.003] 0.89 ±0.08 [.035 ±.003] 2.01 ±0.08 [.079 ±.003] (2 Holes) 5.08 ±0.05 [.200 ±.002] 5.08 ±0.05 [.200 ±.002] 2.54 [.100 10.16 ±0.08 [.400 ±.003] G S 10.16 ±0.08 [.400 ±.003] (Top View) ±0.05 ±.002] 5.08 ±0.05 [.200 ±.002] 0.89 ±0.08 [.035 ±.003] (Top View) Recommended PC Board Layouts * Screw for board thickness of 2.38 [.093] or greater Part No. 221108-2. Screw for thickness of less than 2.38 [.093] Part No. 221108-4. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 59 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Jacks with Mounting Flanges PC Board/Panel Mount Right Angle Mount Vertical Mount 1/2-28 Thread 1/2-28 Thread 15.88 [.625] 15.88 [.625] Mounting Height +0.13 12.83 -0.00 Dia. [.505 +.005 ] -.000 C L 8.59 [.338] C L 21.21 [.835] 8.59 [.338] 21.21 [.835] 34.93 [1.375] 34.93 [1.375] Mounting Height +0.08 5.54 -0.00 Dia. [.218 +.003 ] -.000 Maximum Panel Thickness 6.1 [.240] Recommended Panel Cutout Lockwasher and Jam Nut Body Material Center Contact Plating VALOX, White Tin Gold Part No. Right Angle Mount Vertical Mount 226978-1 — 226978-3 226987-7 Vertical Mount Right Angle Mount 3.3 [.130] Dia. Clearance Hole for 5-40 Screw 22.86 ±0.08 [.900 ±.003] 22.86 ±0.08 [.900 ±.003] 8.89 [.350] Part No. 1-329632-2 11.43 [.450] 11.43 [.450] Mating Face G Part No. 1-329631-2 G S 2.54 [.100] 0.89 ±0.08 [.035 ±.003] 2.54 [.100] 0.89 ±0.08 [.035 ±.003] 3.3 [.130] Dia. Clearance Hole for 5-40 Screw S (Top View) (Top View) Recommended PC Board Layouts Surface Mount Right Angle Jacks 10.16 ±.0.08 [.400 ±.003] 2.54 [.100] Typ. With Mounting Holes (no post) 1.27 [.050] Typ. B 2.54 [.100] 12.01 ±.0.08 [.079 ±.003] 2 Plcs. +0.13 12.83 -0.00 Dia. [.505 +.005 ] -.000 5.08 [.200] 5.08 [.200] +0.08 5.54 -0.00 Dia. [.218 +.003 ] -.000 Recommended Panel Cutout A Recommended PCB Configuration Body Material With Compliant Post Center Contact Plating Gold High Temp. Gold B A A 6.91 .272 6.91 .272 Dimensions B L 13.18 — .519 13.18 2.79 .519 .110 Without Mounting Post With Compliant Post 415715-1* — — 415715-2* L *IR reflow compatible. Plating: Gold – 0.00076 [.000030] thick. 60 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Vertical Metalized Jacks PC Board Mount Body Plating Recommended PC Board Layouts Style A Center Contact Plating Dielectric Style Silver VALOX A Gold VALOX A Tin VALOX A Gold VALOX A Silver TEFLON B Silver VALOX C Gold VALOX E Gold TEFLON F Gold TEFLON B Silver VALOX C Silver VALOX C Gold VALOX C Gold VALOX C Gold VALOX D Tin VALOX D L 12.7 ±0.08 [.500 ±.003] 6.35 ±0.05 [.250 ±.002] 12.7 ±0.08 [.500 ±.003] 17.45 Sq. [.687] 15.88 [.625] Style B Nickel Drill Holes for 0.94 ±0.05 [.037 ± .002] Dia. Pin (5 Places) 6.35 ±0.05 [.250 ±.002] L 6.88 ±0.08 [.271 ±.003] 1.50 ±0.08 Dia. [.059 ±.003] (4 Holes) Tin-Lead 3.44 ±0.08 [.135 ±.003] 6.88 ±0.08 [.271 ±.003] 20.57 [.810] 1.02 [.040 Style C L ±0.08 ±.003] 3.43 ±0.08 [.135 ±.003] Dia. Leg Length L 6.35 .250 6.35 .250 6.35 .250 3.81 .150 3.30 .130 4.45 .175 6.35 .250 2.54 .100 3.30 .130 3.18 .125 4.45 .175 3.18 .125 4.45 .175 3.43 .135 3.43 .135 Part No. 227699-1 227699-2 227699-3 414460-11 413969-1 222420-1 415189-1 1274360-1 413969-2 414305-1 414305-2 414305-3 414305-4 221123-2 221123-3 With .76 [.030] standoffs on top of legs. 1 Style E (Panel Mount) 6.88 ±0.05 [.271 ±.003] 2.44 ±0.08 Dia. [.096 ±.003] (4 Holes) 3.43 ±0.05 [.135 ±.002] 6.88 ±0.05 [.271 ±.003] 1.32 ±0.08 Dia. [.052 ±.003] 16.64 [.655] 12.70 0.08 [.500 ±.003] 6.35 ±0.06 [.250 ±.002] Drill Hole to Receive 0.940.06 [.037±.002] Dia. Pin, 5 Required 20.78 0.38 [.818 .015] L Style D 12.70 0.08 [.500 ±.003] Style F (Push-On) 1.07 ±0.05 Dia. [.042 ±.002] L 4.32 [.170] 2.578 ± 0.076 [.1015 ± .0030] 1.73 ±0.05 Dia. [.068 ±.002] 6.48 [.255] 15.88 [.625] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 1.02 ± 0.08 Dia. [.040 ± .003] 14.73 [.580] 3.73 [.147] 7.47 [.294] Dimensions are in millimeters over [inches] 2.54 5 Plcs. [.100] 5.16 ± 0.08 [.203 ± .003] 5.16 ± 0.08 [.203 ± .003] www.amp.com/communications/com 2.06 ± 0.05 Dia. [.081 ± .002] 4 Plcs. Specifications subject to change. 61 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Vertical Metalized Jacks, PC Board Mount 7.50 ± 0.08 [.295 ± .003] 24.00 [.945] Signal Contact Hole 1.00 ± 0.08 [.039 ± .003] 2 Plcs. 10.72 ± 0.25 [.422 ± .010] Switching Contact 1.70 ± 0.10 Hole [.067 ± .004] 2.50 ± 0.08 [.098 ± .003] 4 Plcs. 3.00 ± 0.10 [.118 ± .004] 1.50 ± 0.08 [.059 ± .003] 2 Plcs. 10.70 ± 0.08 [.421 ± .003] Recommended PC Board Layout Part No. 1274314-1 (Switching) 3.75 ± 0.08 [.148 ± .003] 24.00 [.945] 1.00 ± 0.08 [.039 ± .003] 10.72 ± 0.25 [.422 ± .010] 1.70 ± 0.10 [.067 ± .004] 2.50 ± 0.08 [.098 ± .003] 3 Plcs. 3.00 ± 0.10 [.118 ± .004] 1.50 ± 0.08 [.059 ± .003] 2 Plcs. 10.70 ± 0.08 [.421 ± .003] Part No. 1274315-1 Body Plating Tin-Lead Tin-Lead Recommended PC Board Layout Contact Plating Silver Silver Dielectric Polyphenylene Polyphenylene Press Fit Vertical Metalized Jack, PC Board Mount 11.94 Dia. [.470] Max. Insulating Bushing Material — Polypropylene Part No. 222163-1 Only to be used on P/N 222006-1 & 222462-1 6.88 ±0.05 [.271 ±.002] +0.08 3.43 ±0.05 [.135 ±.002] 6.88 ±0.05 [.271 ±.002] 20.57 [.810] Max. Part No. 1274314-1 1274315-1 1.5 -0.10 [.059 +.003 ] -.004 Dia. 4 Holes 1.02 ±0.08 Dia. [.040 ±.003] 14.61 Dia. [.575] Recommended PC Board Layout PC Board Thickness Not Less Than 0.99 [.093] 11.94 [.470] Dia. 2.96 [.115] Max. 6.61 [.260] Max. Part No. 222006-1 62 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Right Angle Metalized Jacks, PC Board Mount 6.6 ± 0.08 [.260 ± .003] 10.97 [.432] Mounting Height 3.3 ± 0.08 [.130 ± .003] C L 6.15 [.242] 2.11 ± 0.08 [.083 ± .003] Dia. (4 holes) 6.6 ± 0.08 [.260 ± .003] 28.4 Max. [1.118] Body Plating Dielectric Nickel Polymethylpentene Tin-Lead TEFLON Center Contact Length 4.34 .171 4.34 .171 Part No. 413631-1* 413631-2* 1.17 ± 0.08 Dia. [.046 ± .003] Maximum PC Board Thickness 2.54 [.100] Recommended PC Board Layout 1.19 ±0.18 Dia. [.047 ±.007] 3.81 ±0.08 [.150 ±.003] 6.35 Ref. [.250] 8.64 [.340] 2.39 0.38 [.094 ±.015] 7.62 ±0.08 [.300 ±.003] 21.85 [.860] 25.40 [ 1.000] 7.62 ±0.08 [.300 ±.003] 1.78 ±0.08 Dia. [.070 ±.003] 2 Holes 10° 60° 20° Body Dielectric Contact Nickel Nickel Tin-Lead TPX TPX TPX Gold Gold Gold Part No. 414373-1** 414373-3** 414373-4** **Board retention leg prevents connector from tipping during wave solder. For 414373-3 and 414373-4 only. Recommended PC Board Layouts 6.6 ± 0.08 [.260 ± .003] Right-Angle Metalized Jacks, PC Board/Panel Mount 3.3 ± 0.08 [.130 ± .003] 1.088 ± .020 [27.64 ± 0.51] 2.11 ± 0.08 Dia. [.083 ± .003] 4 holes 6.6 ± 0.08 [.260 ± .003] .603 ± .003 [15.32 ± 0.08] 1.17 ± 0.08 Dia. [.046 ± .003] Body Plating Dielectric Dim. A Part No. Tin-Lead TPX 415025-2 Tin-Lead TPX 11.66 .459 16.26 .640 415372-1 +0.13 4.34 [.171] .242 ± .010 [6.15 ± 0.25] 12.83 -0.00 Dia. [.505 +.005 ] -.000 A 1/2-28 Thread Lockwasher and Jam Nut see page 60. .183 [4.65] +0.08 5.64 -0.00 Dia. [.222 +.003 ] -.000 Maximum Panel Thickness 6.35 [.250] Recommended Panel Cutout Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 63 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Tee Adapters Style A Style B Style C (Jack-Plug-Jack) With Insulated Cover (Jack-Plug-Jack) (Jack-Jack-Jack) D D Insulation Material Polyphenylene oxide D F E E E F Style Body Material and Plating Center Contact Material and Plating BE CU, Gold (30)3 BE CU, Silver (200)3 PH BR, Gold (15)3 PH BR, Silver (200)3 BE CU, Gold (30)3 BE CU, Silver (200)3 PH BR, Gold (15)3 PH BR, Silver (200)3 BE CU, Silver (200)3 BE CU, Gold (30)3 BE CU, Silver (200)3 PH BR, Gold (50)3 Brass, Nickel A Zinc, Nickel B C Zinc, Nickel Brass, Nickel Zinc, Nickel Dielectric TEFLON TEFLON Acetal Acetal Acetal Acetal Acetal Acetal Acetal Acetal TEFLON Acetal D 32.54 1.281 32.54 1.281 33.02 1.300 33.02 1.300 33.02 1.300 33.02 1.300 33.02 1.300 33.02 1.300 33.02 1.300 32.54 1.281 32.54 1.281 32.54 1.281 Dimensions E 26.19 1.031 26.19 1.031 27.31 1.075 27.31 1.075 27.31 1.075 27.31 1.075 27.31 1.075 27.31 1.075 27.31 1.075 31.12 1.225 23.37 .920 23.62 .930 Comparable UG/U Connector F 14.27 .562 14.27 .562 14.50 .571 14.50 .571 14.50 .571 14.50 .571 14.50 .571 14.50 .571 14.50 .571 17.15 .675 Packaging No. Per Pkg. Bulk (100) Individual (1) Bulk (100) Bulk (100) Bulk (100) Bulk (100) Individual (1) 4 Individual (1) 4 Individual (1) Bulk(100) Bulk (100) Bulk (100) 274A 274B — — — — — — — 1 — — — — — Part No. 221543-2 329518 413592-2 413592-4 413592-6 413592-8 413592-9 1-413592-0 1-413592-1 413366-11 413366-22 221988-1 414311-1 Black insulation cover Gray insulation cover 3(Microinches min thickness) 4(Special graphics) 1 2 Tee Adapter Covers 114.55 ± 0.76 [4.510 ± .030] Material — Polypropylene, general purpose Color Part No. Black 221586-1 Ivory 221586-3 15.11 [.595] Dia. 64 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] 5.08 Dia. [.200] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Jack-Jack Adapters Style B Style A Nickel Nickel Center Contact Plating Silver Gold Nickel Gold Body Plating 35.81 [1.410] 32.54 [1.281] Bulkhead Jack-Jack Adapters +0.13 12.83 -0.00 Dia. [.505 +.005 ] -.000 L Max. H Max. Body Plating Center Contact Plating Nickel Silver Nickel Gold1 Nickel Gold2 Dielectric Style Part No. TEFLON TEFLON Polymethylpentene A A 221551-1 221551-3 B 414414-1 Dimensions H L 17.45 .687 17.78 .700 17.78 .700 38.10 1.500 36.07 1.420 36.07 1.420 Dielectric Part No. TEFLON 330024 Polyethylene Polyethylene 228226-1 228226-3 Plating: Gold1 — 0.00127 [.000050] thick Gold2 — 0.00076 [.000015] thick Note: If an Insulating Bushing is required see part number 330620 and Panel Cutout on page 54. +0.06 5.54 -0.00 [.218 +.003 ] -.000 Recommended Panel Cutout H= 11/16 across flats, 20.32 [.800] across points. +0.13 Isolated Bulkhead Jack-Jack Adapter Body Plating Nickel Center Contact Plating Gold 12.83 -0.00 Dia. [.505 +.005 ] -.000 Dielectric Part No. Polymethylpentene 414105-1 +0.06 15.87 [.625] 5.54 -0.00 Dia. [.218 +.003 ] 36.07 [1.420] -.000 Recommended Panel Cutout H= 11/16 across flats, 20.32 [.800] across points. Plug-Plug Adapter Body Plating Nickel Silver 31.8 Ref. [1.252] Right Angle Adapters Style A (Jack-Plug) Body Plating Nickel Nickel Nickel Dielectric Style Part No. TEFLON TEFLON Polymethylpentene A A B 329517 222165-2 414666-1 Part No. 1312105-1 1310727-1 Style B 14.53 Dia [.572] Max. Center Contact Plating Silver Gold Gold M/A-COM Model No. B35P32J999X B35P32E999X 14.53 Dia [.572] Max. 24.13 [.950] Max. 22.89 [.901] Max. 26.97 [1.062] 27.23 [1.072] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 65 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 50 Ohm (Continued) Terminator Plugs 50, 75, 93 Ohm Resistor Specification Tether Plating 1 Watt, 50 Ohm 1 Watt, 75 Ohm 1 Watt, 93 Ohm 0.5 Watt, 75 Ohm 1 Watt, 50 Ohm Body — Nickel Center Contact — Gold Dielectric — Polyethylene 14.53 Dia. [.572] Max. 33.02 [1.300] 1 2 Part No. With Tether Without Tether 221629-11 221629-4 221629-21 221629-5 221629-31 221629-6 1-221629-12 — 1-221629-61 — Tether is conductive with #4 stud size With chain assembly #6 Stud Size Insulated Terminators Long Cover Insulation Material Polyphenylene oxide 38.10 Max. [1.500] 38.10 Max. [1.500] 17.40 [.685] 17.40 [.685] Register Specification Cover Style Long Short Long Short Color Gray 1 Watt, 50 Ohm Black Short Cover* Part No. 413557-1 413364-2 413557-2 413364-1 * The Short Cover is required when mating the Terminator with a Tee Adapter. Jack Covers Shorting Caps 22.10 Max. [.870] 14.53 Dia. [.572] Max. Body Plating Silver Nickel Plating Body — Nickel Center Contact — Gold Part No. 330022 1-330022-2 15.24 [.600] 101.6 [4.000] 14.53 [.572] Dia. Max. #6 Stud Size Part No. 413453-1 66 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm Plugs, Crimp Hex and O Crimp These connectors have been designed for optimum performance and have a true 75 ohm impedance the complete length of the connector. The crimp die tooling listed below is different from the equivalent 50 ohm connectors. 14.53 [.572] Dia. Max. L Max. Plugs RG/U Cable Termination Type Center Contact Plating 179, 179A, 179B, 187, 187A, 161, Belden 9221 Hex Crimp Gold Nickel Polyethelene Commercial O Crimp Gold Nickel Polyethelene Commercial 29.46 1.160 35.56 1.140 179 O Crimp Gold Nickel Polyethelene Economy 27.69 1.090 Body Plating Dielectric Style Dim. L Hex Crimp Gold Nickel Polyethelene Commercial O Crimp Gold Nickel Polyethelene Commercial Hex Crimp Gold Nickel Polyethelene Commercial Hex Crimp Gold Nickel Polyethelene Commercial O Crimp Gold Nickel Polyethelene Commercial 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269 Hex Crimp Gold Nickel Polyethelene Commercial O Crimp Gold Nickel Polyethelene Commercial 29.46 1.160 27.69 1.090 29.46 1.160 29.46 1.160 27.69 1.090 29.46 1.160 27.69 1.090 59, 59A, 59B O Crimp Gold Nickel Polyethelene Economy 27.69 1.090 AT&T 735A AT&T KS 19224 L2, RD179 , Double Braid Belden 8218 302, Belden 89269, 88241, Hi-Temp 62A, Times PL-62, Berk Tek BTDC-59, BTDC-62 Belden 8212, 9104, 9112, 9167, 9240, 9259, 9266, Times FM-59, (RG-59 Type with 20 AWG C.C.) Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. Head 318161-1 Part No. 58425-2 — 413589-8 318451-2 — 221185-8 58559-1 — 414858-2 — — 414918-21,3 58425-2 — 1-413589-0 58174-1 58248-3 1-221185-8 58425-2 — 413589-4 58425-2 — 413589-3 58174-1 58248-3 221185-3 58425-1 — 413589-2 58536-1 58248-2 221185-2 58558-1 — 414858-1 — — 414918-12,3 Hex Crimp Gold Nickel Polyethelene Commercial 29.46 1.160 58425-1 — 413589-1 Hex Crimp Gold Nickel Polyethelene Commercial 29.46 1.160 58425-1 — 413589-9 O Crimp Gold Nickel Polyethelene Commercial 27.69 1.090 58536-1 58248-2 221185-9 58425-1 — 413589-7 58536-1 — 1-221185-0 58536-1 — 221185-1 Hex Crimp Gold Nickel Polyethelene Commercial O Crimp Gold Nickel Polyethelene Commercial Belden 9248, 9114 O Crimp Gold Nickel Polyethelene Commercial 6, 6A O Crimp Gold Nickel Polyethelene Commercial 29.46 1.160 27.69 1.090 25.65 1.010 37.85 1.490 58538-1 58248-1 221185-7 58425-3 — 413589-5 58538-1 58248-1 221185-5 58536-1 — 2-221185-9 58536-1 — 3-221185-1 58538-1 — 3-221185-3 Belden 9145, AT&T 734A Belden 8281, 9141, 9231, Western Electric 724, 728, 3049 Comm/Scope S59 Hec Comm/Scope F59 Hec-z Belden 88281 Hex Crimp Gold Nickel Polyethelene Commercial 29.46 1.160 O Crimp Gold Nickel Polyethelene Commercial 28.45 1.120 28.96 1.140 28.96 1.140 27.69 1.090 O Crimp Gold Nickel Polyethelene Commercial O Crimp Gold Nickel Polyethelene Commercial O Crimp Gold Nickel Polyethelene Commercial Kit includes connector subassembly and ferrule only, center contact part no. 1-414724-0 supplied separately on strip. Kit includes connector subassembly and ferrule only, center contact part no. 414724-4 supplied separately on strip. Terminate with Amp-o-lectric terminating machine 220152-1 with applicator. 1 2 3 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 67 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Plugs for JIS Cables, Crimp Plating Body — Nickel Center Contact — Gold 14.53 [.572] Dia. Max. L Max. JIS Cable Termination Type Dielectric Dim. L 5C-2V Hex Crimp Polymethylpentene 3C-2V Hex Crimp Polymethylpentene 3C-2W Hex Crimp Polymethylpentene 2.5C-2V Hex Crimp Polymethylpentene 2.5C-2W Hex Crimp Polymethylpentene 1.5C-2V Hex Crimp Polymethylpentene 29.46 1.160 29.46 1.160 29.46 1.160 29.46 1.160 29.46 1.160 29.46 1.160 Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Part No. 58425-3 1-413589-2 58425-1 1-413589-1 58425-1 1-413589-4 58425-2 1-413589-6 58425-1 1-413589-5 58425-2 1-413589-3 Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Part No. 58425-2 1-413590-3 58425-1 1-413590-2 Bulkhead Jacks for JIS Cables, Crimp Plating Body — Nickel Center Contact — Gold Dielectric — Polymethylpentene 20.32 [.800] Max. L Max. JIS Cable Termination Type Dielectric Dim. L 2.5C-2V Hex Crimp 75Ω 2.5C-2W Hex Crimp 75Ω 1.5C-2V Hex Crimp 75Ω 36.83 1.450 36.83 1.450 136.83 1.450 58425-2 413590-4* Note: All parts are packaged in 25 pieces per bag unless otherwise noted. **Packaged in 100 pieces per bag. 68 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Right Angle Plugs, Crimp Hex and O Crimp 27.18 Max. [1.070] L Max. 14.53 Dia. [.572] Max. Style Dim. L Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. Head 318161-1 RG/U Cable Termination Type Center Contact Plating 179, 179A, 179B, 187, 187A, 161 Belden 9221 Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 1.553 58425-2 — -413588-8 AT&T 735A Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 1.553 58425-2 — 1-413588-0 AT&T KS 19224 L2, RD179 Double Braid Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 1.553 58425-2 — 413588-4 Belden 8218 Hex Crimp Gold Nickel Polymethylpentene Commercial 58425-2 — 413588-3 Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 1.553 39.45 11.553 58425-1 — 413588-2 O Crimp Gold Nickel Polymethylpentene Commercial 39.88 1.570 58536-1 58248-2 -221402-2 Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 11.553 58425-1 — 413588-1 Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 11.553 58425-3 — 413588-6 Hex Crimp Gold Nickel Polymethylpentene Commercial 39.45 1.553 58425-1 — 413588-9 Hex Crimp Gold Nickel Commercial — 413588-7 Gold Nickel 58536-1 — 221402-4 Hex Crimp Gold Nickel 39.45 1.553 39.88 1.570 39.45 1.553 58425-1 O Crimp Polymethylpentene Polymethylpentene Polymethylpentene 58425-3 — 413588-5 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269 302, Belden 88241, 89269, Hi-Temp 62A, Times PL-62, Berk Tek BTDC-59, BTDC-62 Double Braided 59 Belden 8212, 9104, 9112, 9240, 9167, 9259, 9266, Times FM-59, (RG-59 Type with 20 AWG C.C.) Belden 9145, AT&T 734A Belden 8281, 9141, 9231 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Body Plating Dielectric Commercial Commercial Dimensions are in millimeters over [inches] www.amp.com/communications/com Part No. Specifications subject to change. 69 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Jacks, Crimp Hex and O Crimp 11.08 Dia. [.436] Max. Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. Head 318161-1 Part No. RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric Style Dim. L 179, 179A, 179B, 161, 187, 187A, Belden 9221 Hex Crimp Gold Nickel Polyethelene Commercial 58425-2 — 413760-8 O Crimp Gold Nickel Polyethelene Commercial 318451-2 — 221199-5 AT&T 735A O Crimp Gold Nickel Polyethelene Commercial 33.02 1.300 30.48 1.200 30.48 1.200 58174-1 — 221199-6 AT&T KS 19224 L2, RD179 Double Braid Hex Crimp Gold Nickel Polyethelene Commercial 33.02 1.300 58425-2 — 413760-4 Belden 8218 Hex Crimp Gold Nickel Polyethelene Commercial 58425-2 — 413760-3 Hex Crimp Gold Nickel Polyethelene Commercial 33.02 1.300 33.02 1.300 58425-1 — 413760-2 O Crimp Gold Nickel Polyethelene Commercial 30.48 1.200 58536-1 58248-2 221199-2 Hex Crimp Gold Nickel Polyethelene Commercial 33.02 1.300 58425-1 — 413760-1 Hex Crimp Gold Nickel Polyethelene Commercial 33.02 1.300 58425-1 — 413760-9 Hex Crimp Gold Nickel Polyethelene Commercial 58425-1 — 413760-7 O Crimp Gold Nickel Polyethelene Commercial 33.02 1.300 30.48 1.200 58536-1 — 221199-1 Hex Crimp Gold Nickel Polyethelene Commercial 33.02 1.300 58425-3 — 413760-5 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269 302, Belden 88241, 89269, Hi-Temp 62A, Times PL-62, Berk Tek BTDC-59, BTDC-62 Belden 8212, 9104, 9112, 9240, 9167, 9259, 9266, Times FM-59, (RG-59 Type with 20 AWG C.C.) AT&T 734A, Belden 9145 Belden 9248, 9114 Belden 8281, 9141, 9231, Western Electric 724, 728, 3049 70 L Max. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Bulkhead Jacks, Crimp Hex and O Crimp +0.13 12.83 -0.20 Dia. [.505 +.005 ] -.000 +0.08 5.54 -0.00 [.218 +.003 ] 34.93 Max. [1.375] 20.32 [.800] Max. -.000 Maximum Panel Thickness 6.1 [.240] Recommended Panel Cutout Interchangeable Dies for PRO-CRIMPER Hand Tool 354940-1 or PRO-CRIMPER Adapter 679304-1 Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. Head 318161-1 Part No. 58425-2 — 413590-8 318451-2 — 221221-5 RG/U Cable Termination Type Center Contact Plating 179, 179A, 179B, 161, 187, 187A, Belden 9221 Hex Crimp Gold Nickel Polyethelene Commercial O Crimp Gold Nickel Polyethelene Commercial 36.83 1.450 34.93 1.375 Hex Crimp Gold Nickel Polyethelene Commercial 36.83 1.450 58425-2 — 413590-4 Hex Crimp Gold Nickel Polyethelene Commercial 58425-2 — 413590-3 O Crimp Gold Nickel Polyethelene Commercial 36.83 1.450 34.93 1.375 58174-1 58248-3 221221-3 Hex Crimp Gold Nickel Polyethelene Commercial 36.83 1.450 58425-1 — 413590-2 58536-1 58248-2 221221-2 AT&T KS 19224 L2, RD179 Double Braid Body Plating Dielectric Style Dim. L Belden 8218 140, 210, 62, 62A, 62B, 59, 59A, 59B, Belden 9291, 9209, 9269 302, Belden 88241, 89269, Hi-Temp 62A, Times PL-62, Berk Tek BTDC-59, BTDC-62 Double Shield RG-59 Belden 8212, 9104, 9112, 9240, 9167, 9259, 9266, Times FM-59 (RG-59 Type with 20 AWG C.C.) AT&T 734A, Belden 9145 Belden 9114, 9248 Belden 8281, 9141, 9231, Western Electric 724, 728, 3049 O Crimp Gold Nickel Polyethelene Commercial 34.93 1.375 Hex Crimp Gold Nickel Polyethelene Commercial 36.83 1.450 58425-1 — 413590-1 Hex Crimp Gold Nickel Polyethelene Commercial 36.83 1.450 58425-3 — 413590-6 Hex Crimp Gold Nickel Polyethelene Commercial 36.83 1.450 58425-1 — 413590-9 O Crimp Gold Nickel Polyethelene Commercial 34.93 1.375 58536-1 58248-2 221221-7 Hex Crimp Gold Nickel Polyethelene Commercial 58425-1 — 413590-7 O Crimp Gold Nickel Polyethelene Commercial 36.83 1.450 34.93 1.375 58536-1 — 221221-1 Hex Crimp Gold Nickel Polyethelene Commercial 36.83 1.450 58425-3 — 413590-5 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 71 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Bulkhead Solder Jacks Front Mount Accepts .054 Dia. Max. Wire 27.43 Max. [1.083] Plating 27.43 [ 1.083] Accepts .054 Dia. Max. Wire Max. Body — Nickel Center Contact — Silver 3/8-32 Thread 3/8-32 Thread 9.75/9.65 [.384./380] Dia. 13.09 Dia. [.515] Max. 13.09 Dia. [.515] Max. Part No. 415187-1 Part No. 221244-1 (without Solder Terminal) (with Solder Terminal) Note: If insulating bushing required use part no. 227223-1 or 221951-1 (for details, reference page 56). Note: If insulating bushing required use part no. 227223-1 or 221951-1 (for details, reference page 56). 4.04/3.96 [.159/.156] Maximum Panel Thickness 3.18 [.125] Recommended Panel Cutout Bulkhead Jack PC Board Mount 3.30 [.130] 11.07 Max. [.436] 20.8 [.820] Ø 12.70 ± 0.1 [.500 ± .004] 11.2 ± 0.1 [.441 ± .004] Part No. 1274086-1 Bulkhead Solder Jack Rear Mount Accepts . .050 Dia. Max. WIre Lockwasher and Jam Nut see page 74. 17.78 Dia. [.700] Max. 1/2-28 Thread +0.13 12.83 -0.00 Dia. [.505 +.005 ] -.000 Plating Body — Nickel Center Contact — Gold Dielectric — Polymethylpentene +0.08 5.54 -0.00 [.218 +.003 ] 31.75 Max. [ 1.250] -.000 Maximum Panel Thickness 6.35 [.250] Recommended Panel Cutout Part No. 414217-1 72 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Right-Angle Jacks PC Board/Panel Mount VALOX Body Metal Body 1/2-28 Threads 1/2-28 Threads C Mtg. Hgt. C Mtg. Hgt. Outer Shell — Nickel Dielectric — Polymethylpentene Lockwasher and Jam Nut see page 74. C L C L A B A B 34.93 [1.375] 34.93 [1.375] +0.13 12.83 -0.00 Dia. [.505 +.005 ] -.000 Body Material L +0.13 5.54 -0.00 [.218 +.005 ] -.000 Maximum Panel Thickness 6.1 [.240] Recommended Panel Cutout Recommended PC Board Layouts VALOX, White *VALOX, White (Economy) VALOX, Black A Gold1 6.91 .272 21.08 .830 13.88 .519 3.48 .137 — 413194-1 Gold1 6.91 .272 21.21 .835 13.88 .519 3.48 .137 * — 415634-2 Gold1 21.08 .830 21.21 .835 21.21 .835 21.21 .835 20.83 .820 20.83 .820 20.83 .820 20.83 .820 20.83 .820 21.21 .835 20.83 .820 20.83 .820 20.83 .820 20.83 .820 20.83 .820 20.83 .820 13.88 .519 13.88 .519 15.88 .625 15.88 .625 15.88 .625 15.88 .625 15.88 .625 15.88 .625 12.70 .500 15.88 .625 15.88 .625 15.88 .625 12.70 .500 12.70 .500 12.70 .500 12.70 .500 3.48 .137 3.48 .137 3.48 .137 3.48 .137 2.16 .085 — 413194-2 — 415634-1 — 415633-1 — 414459-1 — 222092-1 Gold1 6.91 .272 6.91 .272 8.59 .338 8.59 .338 8.25 .325 8.25 .325 8.25 .325 8.25 .325 6.91 .272 8.56 .337 8.25 .325 8.25 .325 6.91 .272 6.91 .272 6.91 .272 6.91 .272 Gold1 6.91 .272 21.21 .835 13.88 .519 *VALOX, Black (Economy) Gold1 VALOX, White Gold2 Metal Gold1 Metal Gold1 Gold1 Without Mounting Posts 10.16 ±0.08 [.400 ±.003] 2.64 [.104] Dia. Clearance Hole for 2-56 Self-Tapping Screw* (2 Holes) 5.08 ±0.05 [.200 ±.002] 5.08 ±0.05 [.200 ±.002] G 2.54 ±0.05 [.100 ±.002] S Mating Face 0.89 ±0.08 [.035 ±.003] (Top View) With Mounting Posts 10.16 ±0.08 [.400 ±.003] 2.01 ±0.08 [.079 ±.003] (2 Holes) 5.08 ±0.05 [.200 ±.002] 5.08 ±0.05 Mating [.200 ±.002] Face G 2.54 ±0.05 [.100 ±.002] S 0.89 ±0.08 [.035 ±.003] (Top View) * Screw for panel thickness of 2.38 [3/32] or greater * Part No. 221108-2. * Screw for panel thickness of less than 2.38 [3/32] * Part No. 221108-4. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 *Metal (Economy) Gold1 Gold1 *Metal with Compliant Posts (Economy) Tin-Lead Metal Silver Metal Gold1 Metal Gold1 Metal Gold1 *Metal (Economy) *Metal (Economy) *High Temp w/ Compliant Posts (Economy) Part No. Without With Mounting Posts Mounting Posts Center Contact Plating Gold1 Gold1 Dimensions B C L — 222093-1 3.48 .137 — 414409-1 — — 414410-1 3.48 .137 3.48 .137 2.16 .085 3.48 .137 3.48 .137 — — 415417-1 415419-1 222092-2 222092-3 414907-1 1274072-1 3.48 .137 3.48 .137 2.79 .110 — 1274084-1 1274084-2** 415655-1** **Stamped and formed contact, Phosphor Bronze contact material **IR Reflow Compatible Plating: Gold1 — 0.00076 [.000030] thick Gold2 — 0.00127 [.000050] thick Note: If an Insulating Bushing is required see part number 330620 and Panel Cutout on page 54. Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 73 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Vertical Jacks PC Board/Panel Mount VALOX Body Metal Body L L Plating 1/2-28 Thread Outer Shell — Nickel Dielectric — Polymethylpentene 15.88 [.625] B 1/2-28 Thread 15.88 [.625] B 34.93 [1.375] Mtg. Hgt. 34.93 [1.375] Mtg. Hgt. +0.13 12.83 -0.00 Dia. [.505 +.005 ] -.000 +0.13 5.54 -0.00 [.218 +.005 ] -.000 Maximum Panel Thickness 6.1 [.240] Recommended Panel Cutout Lockwasher and Jam Nut Part No. 1-329632-2 Center Contact Plating Dim. B Dim. L VALOX, Black VALOX, Black *VALOX, Black (Economy) *VALOX, White (Economy) Gold1 13.48 .137 3.48 .137 414933-1 413528-1 Gold2 21.2 .835 21.21 .835 — 413528-3 Gold 21.21 .835 3.48 .137 — 415632-1 Gold1 21.21 .835 3.48 .137 — 415632-2 Metal Gold1 222132-1 Tin-Lead 3.48 .137 3.48 .137 414983-1 *Metal (Economy) 20.83 .820 21.21 .835 — 415520-1 *Stamped and formed contact, Phosphor Bronze contact material Plating: Gold1 — 0.00076 [.000030] thick Gold2 — 0.00127 [.000050] thick Note: If an Insulating Bushing is required see part number 330620 and Panel Cutout on page 54. Part No. 1-329631-2 Without Mounting Posts 2.54 ±0.05 [.100 ±.002] 10.16 ±0.08 [.400 ±.003] * Screw for panel thickness of 2.38 [3/32] or greater * Part No. 221108-2. * Screw for panel thickness of less than 2.38 [3/32] * Part No. 221108-4. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 With Mounting Posts 2.64 [.104] Dia. Clearance Hole for 2-56 Self-Tapping Screw* (2 Holes) 5.08 ±0.05 [.200 ±.002] 74 Part No. Without With Mounting Mounting Posts Posts Body Material G S 10.16 ±0.08 [.400 ±.003] 0.89 ±0.08 [.035 ±.003] 2.01 ±0.08 [.079 ±.003] (2 Holes) 5.08 ±0.05 [.200 ±.002] 5.08 ±0.05 [.200 ±.002] 2.54 [.100 10.16 ±0.08 [.400 ±.003] G S 10.16 ±0.08 [.400 ±.003] (Top View) ±0.05 ±.002] 5.08 ±0.05 [.200 ±.002] 0.89 ±0.08 [.035 ±.003] (Top View) Recommended PC Board Layouts Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Vertical Metalized Jacks PC Board Mount Style A Style B Style C L L L Plating Dielectric — TEFLON 17.45 Sq. [.687] 20.57 [.810] 16.64 [.655] 15.88 [.625] 6.88 ±0.08 [.271 ±.003] 12.7 ±0.08 [.500 ±.003] 6.35 ±0.05 [.250 ±.002] 3.44 ±0.08 [.135 ±.003] 1.50 ±0.08 [.059 ±.003] Dia. (4 Holes) 3.43 ±0.05 [.135 ±.002] 6.88 ±0.05 6.88 ±0.08 [.271 ±.003] [.271 ±.003] 12.7 ±0.08 [.500 ±.003] Drill Holes for 0.94 ±0.05 [.037 ± .002 ] Dia. Pin (5 Places) 6.88 ±0.05 [.271 ±.003] 6.35 ±0.05 [.250 ±.002] 2.44 ±0.08 Dia. [.096 ±.003] (4 Holes) 1.32 ±0.08 Dia. [.052 ±.003] 3.43 ±0.08 [.135 ±.003] 1.02 ±0.08 [.040 ±.003] Dia. Recommended PC Board Layout Press Fit Vertical Metalized Jacks PC Board Mount Body Plating Center Contact Plating Style Nickel Gold B Tin-Lead Gold B Tin-Lead Gold B Tin-Lead Gold C Nickel Silver A 11.49 Dia. [.470] Max. Leg Length L 3.30 .130 3.30 .130 6.35 .250 4.44 .175 6.35 .250 Part No. 1274291-2 1274291-1 1274359-1 414394-1 413986-1 6.88 ±0.1 [.271 +.003] –.004 3.43 ±0.05 [.135 ±.002] 1.5 ±0.1 Dia. [.059 +.004] –.003 (4 Plated-Thru Holes) 6.88 ±0.05 [.271 ±.002] 1.02 ±0.08 Dia. [.040 ±.003] (Plated-Thru Hole) A Max. Dim. A 20.57 .810 16.26 .640 Part No. 222462-1 414088-1 Recommended PC Board Layout Insulating Bushing Material — Nylon Part No. 222163-1 Only to be used on P/N 222462-1 and 222006-1 14.61 Dia. [.575] 11.94 [.470] Dia. 2.96 Max. [.115] 6.61 Max. [.260] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 75 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Press Fit Vertical Metalized Jacks PC Board Mount 1.7 ±0.05 Dia. [.067 ±.002] (2 Places) For Drive Screw 17.48 Sq. [.688] (Continued) 12.7 ±0.05 [.500 ±.002] PC Board Thickness (Min.) 2.36 .093 3.17 .125 6.35 ±0.05 [.250 ±.002] 1.02 ±0.08 [.040 ±.003] (Plated-Thru Hole 3 Places) Part No. 221336-3 221336-4 12.7 ±0.05 [.500 ±.002] 15.88 Max. [.625] 6.35 ±0.05 [.250 ±.002] Recommended PC Board Layout Press Fit, Bulkhead Vertical Metalized Jack 6.88 [.271] 4.37 ± 0.51 [.172 ± .020] 5 Plcs. 10.80 [.425] includes hardware 3.43 [.135] 3.43 [.135] ø 12.83 + 0.13 – 0.00 [ø .505 + .005] – .000 28.78 [1.133] 24.41 [.961] 5.54 + 0.08 – 0.00 [.218 + .003] 6.88 [.271] – .000 Ø 1.02 ± 0.08 [.040 ± .003] Holes Plated Through 5 Plcs. Part No. 1274124-2 Recommended PC Board Layout Right Angle Metalized Jacks PC Board Mount 10.97 [.432] Mounting Height C L 6.15 [.242] 6.6 ± 0.08 [.260 ± .003] 28.4 Max. [1.118] 3.3 ± 0.08 [.130 ± .003] 2.11 ± 0.08 [.083 ± .003] Dia. (4 holes) 6.6 ± 0.08 [.260 ± .003] Body Plating Dielectric Contact Plating Nickel Tin-Lead Nickel Tin-Lead Nickel TPX TEFLON TPX TPX TPX Gold2 Gold2 Gold2 Gold1 Gold1 Center Contact Dimension .171 [.007] .171 [.007] .131 [.005] .171 [.007] .171 [.007] Length Part No. 4.34 [.171] 4.34 [.171] 4.34 [.171] 4.34 [.171] 4.34 [.171] 413558-1 413558-2 413558-3 413558-4 413558-5 Gold1 — 0.00076 [.000030] thick Gold2 — 0.00127 [.000050] thick 1.17 ± 0.08 Dia. [.046 ± .003] Maximum PC Board Thickness 2.54 [.100] Recommended PC Board Layout 11.43 ± 0.43 [.450 ± .017] 3.81 ± 0.08 [.150 ± .003] 11.07 Max. [.436] 17.78 [.700] 7.62 ± 0.08 [.300 ± .003] 21.84 [.860] 25.40 ± 0.38 [1.000 ± .015] 1.19 ± 0.18 Dia. [.047 ± .007] 7.62 ± 0.08 [.300 ± .003] 1.78 ± 0.08 Dia. [.070 ± .003] Part No. 1274127-1 76 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) 27.64 ± 0.51 [1.088 ±.020] Right Angle Metalized Jacks PC Board/Panel Mount 12.83+0.13 -0.00 [.505+.005] -.000 Dia. 6.15 ± 0.25 [.212 ±.010] 10.97 ± 0.18 [.432 ±.007] A 5.64+0.08 -0.00 [.222+.003] -.000 1/2-28 Thread Maximum Panel Thickness 6.35 [.250] 4.34 [.171] Recommended Panel Cutout 1.088 ± .020 [27.64 ± 0.51] .603 ± .003 [15.32 ± 0.08] 4.34 [.171] .242 ± .010 [6.15 ± 0.25] Body Plating Dielectric Tin-Lead TPX Tin-Lead TPX Dim. A 16.26 .640 11.66 .459 A Part No. 1274028-1 415373-1 1274425-2 .183 [4.65] 1/2-28 Thread Press Fit Right Angle Metalized Jack PC Board Mount Part No. 28.27 ±0.25 [1.113 ±.010] 6.35 [.250] 19.53 ±0.25 [.769 ±.010] 4.57 ±0.25 [.180 ±.010] 1.02 ±0.08 Dia. [.040 ±.003] 3 Plcs. Plated Thru Hole 12.70 [.500] 1.70 Dia. [.067] 2 Plcs. Plated Thru Hole For Drive Screw 14.48 Max. [.570] 8.59 ±0.25 [.338 ±.010] 12.70 [.500] 6.35 [.250] 4.94 ±0.76 [.195 ±.030] 2 Plcs. 4.65 ±0.51 [.183 ±.020] 2 Plcs. 4.44 ±1.14 [.175 ±.045] Recommended PCB Configuration Bulkhead Jack-Jack Adapter Right Angle Adapter Plating Plating Body — Nickel Center Contact —Gold Dielectric — Polymethylpentene Body — Nickel Center Contact —Gold Dielectric — Polymethylpentene (Jack-Plug) 12.83+0.13 -0.00 [.505+.005] -.000 14.53 Dia. [.572] Max. Dia. 5.54+0.08 11/16 36.07 [1.420] -0.00 [.218+.003] -.000 22.89 [.901] Max. 26.97 [1.062] Dia. Part No. 222117-1 Maximum Panel Thickness 6.35 [.250] Part No. 415020-1 Recommended Panel Cutout Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 77 Catalog 1307191 Revised 10-00 RF Coax Connectors BNC Connectors, 75 Ohm (Continued) Bulkhead Jack-Push On Plug Adapter 0.13 Ø 9.65 +– 0.00 + .005 [.380 – .000 ] Ø 8.43 Max. [.332] 8.89 ± 0.13 [.350 ± .005] Ø 14.35 Max. [.565] 41.92 [1.650] Recommended Panel Cutout Part No. 1274007-1 78 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Decoupled Connectors Product Facts ■ Built-in chip capacitors filter high-frequency noise to panel ground ■ PC board mounting with vertical and standard or low-profile right angle configurations ■ Cable mount bulkhead BNC version available ■ Drop-in replacement for AMP standard BNC printed circuit board connectors ■ One-piece design and robotic capacity to reduce assembly time AMP Capacitively Decoupled connectors provide the fast, better way to reduce noise and reduce ground loops on coaxial interconnections. The highfrequency noise generated by fast rise times can cause both false triggering of circuits as well as emissions that can be radiated or conducted outside the equipment. Such emissions can interfere with nearby equipment. Ground loops are also a problem for networked systems. Ground loops are caused when two interconnected units are at different voltage potentials. The typical way to handle such EMI and ground loop problems is to decouple the cable shield from the ground panel by soldering a ceramic disk capacitor between the cable shield and the panel. The capacitor shunts high-frequency noise to ground. While effective, this approach is time consuming and expensive. The Capacitively Decoupled connector has built-in chip capacitors. These capacitors establish the electrical contact between the outer shield and a clip. This clip pro- vides a short electrical path between the capacitors and panel. As a result, high-frequency noise is effectively shunted to ground, while the DC path is blocked. The connectors offer compatibility in design and manufacture. The same footprint and dimensional envelope make them a drop-in replacement for AMP standard BNC or TNC printed circuit board connectors. In addition, they can be robotically picked and placed for high-speed automated assembly to pc boards. Product Specification 108-1263 — BNC Decoupled PCB Press-Fit Connection 108-1269 — BNC Decoupled PCB Connectors Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 79 Catalog 1307191 Revised 10-00 RF Coax Connectors Decoupled Connectors (Continued) PC Board/Panel Mount Jacks Decoupled to Panel Style A Vertical BNC 15.08 [.625] Material Body — VALOX, black Dielectric — Polymethylpentene 20.96 [.825] Note: Both styles are shown with a standard clip. See next page for other clip styles. For height dimensions see chart on page 82. 34.93 [1.375] 2.01 ±0.08 [.079 ±.003] (2 Holes) 5.08 ±0.05 [.200 ±.002] 12.83+0.13 -0.00 5.08 ±0.05 ±.002] 2.54 ±0.05 [.200 [.100 ±.002] 10.16 ±0.08 [.400 ±.003] [.505+.005] -.000 Dia. 0.89 ±0.08 [.035 ±.003] G S 10.16 ±0.08 [.400 ±.003] 5.54+0.08 -0.00 [.218+.003] -.000 (Top View) Maximum Panel Thickness 6.1 [.240] Recommended PC Board Layout Recommended Panel Cutout Style B Right Angle BNC B CL 20.96 [.825] A 10.16 ±0.08 [.400 ±.003] 2.01 ±0.08 [.079 ±.003] (2 Holes) 5.08 ±0.05 [.200 ±.002] 5.08 ±0.05 [.200 ±.002] 2.54 ±0.05 [.100 ±.002] G S 34.93 [1.375] 12.83+0.13 -0.00 [.505+.005] -.000 Dia. Mating Face 0.89 ±0.08 [.035 ±.003] 5.54+0.08 -0.00 [.218+.003] -.000 (Top View) Recommended PC Board Layout 80 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Maximum Panel Thickness 6.1 [.240] Recommended Panel Cutout www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Decoupled Connectors (Continued) Clip Styles 19.30 Max. [.760] Clip Width 14.76 Clip [.581] Width 20.96 [.825] 20.96 [.825] Standard Flush For closer centerline-to-centerline connector spacing .304 [.012] .304 [.012] 2.54 [.100] Max. Recommended Panel Mount 2.54 [.100] Max. Recommended Panel Mount 20.96 [.825] Extended For use with or without a jam nut Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Shortening Bar 20.96 [.825] Short Electrical Path For reduced series inductance in ground path www.amp.com/communications/com Specifications subject to change. 81 Catalog 1307191 Revised 10-00 RF Coax Connectors Decoupled Connectors (Continued) PC Board/Panel Mount Jacks Decoupled to Panel Mounting Post Styles (Continued) L L Standard BNC Description Capacitance/ Voltage Clip Mounting Post Vertical 50 9400pF 1500VDC 9400pF 1500VDC 9400pF 1500VDC 9400pF 1500VDC 9400pF 1500VDC 20000pF 500VDC 7900pF 1600VDC 9400pF 1500VDC 9400pF 1500VDC 500pF 2200VDC 9400pF 500VDC 9400pF 500VDC 9400pF 500VDC 9400pF 500VDC 9400pF 1500VDC 9400pF 1500VDC 9400pF 1500VDC 9400pF 1500VDC 9400pF 1500VDC Standard Standard Standard Right Angle 50 Standard Right Angle W/O Mounting Post 502 Low Profile Right Angle 50 Low Profile Right Angle W/Special Clip & High Temperature Housing 50 Low Profile Right Angle W/High Temperature Housing 50 Low Profile Right Angle 75 Ultra Low Profile Right Angle 50 Ultra Low Profile Right Angle 75  L Mounting Post Length 3.48 .137 4.01 .158 2.79 .110 Standard Standard Standard Compliant Standard — — Standard Standard Standard Standard Standard Compliant Standard Compliant Standard Compliant Standard Standard Extended Compliant Extended Compliant Flush Compliant Flush Compliant Standard Standard 4.01 .158 4.01 .158 2.79 .110 4.70 .185 2.79 .110 4.01 .158 4.70 .185 2.79 .110 4.70 .185 2.79 .110 4.01 .158 4.01 .158 2.79 .110 4.01 .158 2.79 .110 Standard Standard Standard Compliant Standard Standard Standard Compliant Compliant B* A* Style1 Part No. — — A 413476-2 15.88 .625 15.88 .625 15.88 .625 13.18 .519 13.18 .519 13.18 .519 13.18 .519 13.18 .519 13.18 .519 13.18 .519 13.18 .519 13.18 .519 13.18 .519 13.18 .519 6.17 .243 6.17 .243 6.17 .243 6.17 .243 8.59 .338 8.59 .338 8.59 .338 6.91 .272 6.91 .272 6.91 .272 6.91 .272 6.91 .272 6.91 .272 6.91 .272 6.91 .272 6.91 .272 6.91 .272 B 413524-2 B 413524-5 B 414215-1 B 413515-2 B 413515-3 B 413515-7 B 413515-8 B 413515-9 B 1-413515-1 B 414284-1 B 414284-2 B 414352-1 B 414352-2 — B 414094-2 11.68 .460 11.68 .460 11.68 .460 11.68 .460 — 415057-1 — 415057-2 — 415103-1 — 415103-2 B* A* Style1 Part No. 13.18 .519 6.91 .272 B 414138-1 See pages 80 and 81 for Connector Styles. See customer drawing for PC Board Layout. *See page 80 for dimension reference. 1 2 TNC Description Capacitance/ Voltage Clip Mounting Post Low Profile Right Angle 50 5400pF 1500VDC Standard Standard L Mounting Post Length 4.01 .158 See pages 80 and 81 for Connector Styles. See customer drawing for PC Board Layout. *See page 80 for dimension reference. 1 2 82 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Decoupled Connectors (Continued) Right Angle BNC Jack PC Board/Panel Mount Decoupled to Panel ESD Protected ESD Protection ESD Device See page 80 Style B for panel cutout and recommended PC board configuration. 1/2-28 Thread Note: See AMP Customer drawing for voltage breakdown rating. Description Capacitance/ Voltage Contact Plating Clip Mounting Post L Mounting Post Length B* A* Part No. 7900pF 1500VDC Gold1 Standard Compliant 2.79 .110 13.18 .519 6.91 .272 414651-3 9400pF 1500VDC Gold1 Short Electrical Path Compliant 4.70 .185 13.18 .519 6.91 .272 415010-1 9400pF 1500VDC Gold1 Standard Standard 4.01 .158 15.88 .625 8.59 .338 415085-1 9400pF 1500VDC Gold1 Flush Compliant 2.79 .110 13.18 .519 6.91 .272 415216-1 9400pF 1500VDC Gold1 Extended Compliant 2.79 .110 13.18 .519 6.91 .272 1274062-1 50 Product Low Profile Right Angle W/ ESD Protection Low Profile Right Angle W/ Short Electrical Path ESD Protection 75 Product Standard Right Angle W/ ESD Protection Low Profile Right Angle ESD Protected Low Profile Right Angle ESD Protected *See page 80 for dimension reference. Right Angle BNC Jack PC Board/Panel Mount Decoupled to Board ESD Protected Capacitance 9400pF 13.18 [.519] Voltage 1500VDC ESD Device Compliant Board Lock Part No. 415205-1 2.01 ± 0.08 [.079 ± .003] Dia. 2 Holes 10.16 ± 0.08 [.400 ± .003] + 0.13 12.83 - 0.00 .005 ] [.505 +- .000 Dia. 0.89 ± 0.08 [.035 ± .003] Dia. 2 Holes 2.54 ± 0.05 [.100 ± .002] + 0.13 11.13 - 0.00 .005 ] [.438 +- .000 5.08 ± 0.05 [.200 ± .002] Recommended PC Board Layout Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Recommended Panel Cutout www.amp.com/communications/com Specifications subject to change. 83 Catalog 1307191 Revised 10-00 RF Coax Connectors Decoupled Connectors (Continued) 28.27 ± 0.25 [1.113 ± .010] Press-Fit, Right Angle BNC Jacks, PC Board Mount Decoupled to Board 19.53 ± 0.25 [.769 ± .010] 4.57 ± 0.25 [.180 ± .010] 6.35 [.250] 6.35 [.250] 17.48 ± 0.25 [.688 ± .010] Ground Area Part No. 1274026-1 50 Ohm Part No. 1274027-1 75 Ohm Press-Fit, Vertical BNC Jacks, PC Board Mount Decoupled to Board 12.70 [.500] 6.35 [.250] 1.02 ±0.08 Dia. [.040 ±.003] 3 Plc. Plated Thru Hole Material 12.70 [.500] 1.70 Dia. [.067] 2 Plc. Plated Thru Hole For Drive Screw Dielectric— TEFLON Isolation Pad — Polyester Plating 9.14 [.360] Dia. OD 6.35 [.250] Dia. ID Recommended PC Board Layout 17.48 Sq. [.688] Body — Nickel Ground Clip — Nickel Center Contact — Gold Action Pin Legs — Gold 1.02 ±0.08 Dia. [.040 ±.003] 3 Plc. Plated Thru Hole 12.70 [.500] 1.70 Dia. [.067] 2 Plc. Plated Thru Hole For Drive Screw 14.48 Max. [.570] 4.65 ± 0.51 2 Plc. [.183 ± .020] 12.70 [.500] 6.35 [.250] 15.88 Max. [.625] Ground Area 9.14 [.360] Dia. OD 6.35 [.250] Dia. ID Recommended PC Board Layout Part No. 414553-1 50 Ohm Part No. 414493-1 75 Ohm BNC Bulkhead Jacks, Crimp 12.83+0.13 40.64 Max. [1.600] -0.00 [.505+.005] -.000 Dia. 5.54+0.08 -0.00 [.218+.003] 16.51 [.650] Max. over points 50 50 75 75 84 -.000 Recommended Panel Cutout Connector Cable Range Selection Code RG/U Cable Termination Type Center Contact Plating Body Plating Dielectric Style D B — — RG58, 58A, 58B, 58C RG174, 174A, 316, 188, 188A RG179, 187 Belden 9259 Hex Crimp Hex Crimp Hex Crimp Hex Crimp Gold Gold Gold Gold Nickel Nickel Nickel Nickel Polymethylpentene Polymethylpentene Polymethylpentene Polymethylpentene Commercial Commercial Commercial Commercial Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Interchangeable Dies for Hand Tool 69710-1 & 626 Pneu. Head 318161-1 58436-1 58436-3 58425-2 58425-1 www.amp.com/communications/com Part No. 414758-1 414758-2 414614-1 414614-3 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Self-Terminating PC Board Connectors Product Facts ■ Built-in chip resistor terminates the signal line to the proper characteristic impedance when in the unmated state ■ Can be ordered with standard resistance values (50, 75 and 100 Ohms) ■ Fits into printed circuit board footprint of standard BNC PCB connectors ■ One-piece design is compatible with robotic insertion and wave soldering AMP Self-Terminating printed circuit board BNC connectors provide the capability to automatically terminate an input-output port to the system characteristic impedance. This feature eliminates the need for external terminators when an I/O port is not being used. The Self-Terminating BNC jack contains a chip resistor which bridges the signal and ground paths when the connector is not mated to a BNC plug. When mated, the resistor is switched out of the circuit for direct signal transmission to the board. The footprint of this connector is compatible with standard BNC connectors, allowing it to be easily installed into existing circuit board designs and suitable for robotic insertion for high speed automated assembly onto the PC board. The Self-Terminating BNC is available in standard resistance values for use in networking and video systems. Contact AMP for new designs that include switching and capacitively decoupled versions. 14.73 [.580] 15.86 [.625] 1/2-28UNEF-2A Material Body — Polyester, PBT, black Dielectric — Polyester, PBT, natural Plating Shell — Tin Lead Center Contact — Gold on mating end and Tin Lead on solder tails 34.96 [1.375] 20.96 [.825] Product Self-Terminating BNC PCB Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Termination Resistance 50Ω 75Ω www.amp.com/communications/com Part Number 414367-1 414367-2 Specifications subject to change. 85 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 86 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Twin BNC Connectors Product Facts ■ Crimp connectors require only one-stroke crimping of both conductors, plus braid and cable support ■ Lower installed cost with one-stroke crimp ■ Reduced noise levels because of AMP solderless crimping techniques ■ Captive inner contact stability ■ No danger of heat damage to coaxial cable ■ Ease of inspection ■ Listed under the Component Program of Underwriters Laboratories Inc., File No. E81956 ■ PC Board soldered connectors are recognized under the Component Program of Underwriters Laboratories Inc., File No. E81956 R R ■ Certified by Canadian Standards Association File No. LR 7189 The Twin BNC Connector is a quick connect/disconnect, weatherproof connector designed in accordance with MIL-C-39012 to meet the stringent requirements of MIL-STD-1553 Multiplex Data Bus. These twin coaxial cable connectors are a unique development by AMP which has resulted in the production of high level RF components. Termination of these connectors to twin conductor cable is made with AMP exclusive one crimp method which simultaneously terminates inner conductors, outer braid and cable support with one stroke of the matching AMP tool. These rugged connectors accommodate today’s most commonly used twin conductor cable sizes. Electrical Characteristics Environmental Characteristics Nominal Impedance — Non-constant Working Voltage — 500 volts rms sea level Insulation Resistance — 5000 megohms min. Dielectric Withstanding Voltage — 1500 volts rms sea level Temperature Range — -55°C to +85°C Vibration — MIL-STD-202, Method 204, Condition B Shock — MIL-STD-202, Method 213, Condition I, 100 G’s Salt Spray — MIL-STD-202, Method 101, Condition B Temperature Cycling — MIL-STD202, Method 102, Condition C Mechanical Characteristics R Materials Brass — QQ-B-626 Beryllium Copper — QQ-C-530 TEFLON — MIL-P-19468 Polypropylene — General purpose Copper, Annealed — QQ-C-576 Phosphor Bronze — QQ-B-750 Silicone Rubber — ZZ-R-765 Mating/Unmating — Bayonet lock-quick connect/ disconnect Cable Attachment — Crimp type Simultaneous center and braid Coupling Nut Retention — 100 lbs. [444 N] min. Cable Retention — 25 lbs. [111 N] min., RG-108A/U cable Durability — 200 cycles per MIL-C-39012 Plating Packaging — All connectors are packaged individually unless otherwise noted. Silver — QQ-S-365 Nickel — QQ-N-290 Tin Lead — ASTM-B-545 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 87 Catalog 1307191 Revised 10-00 RF Coax Connectors Twin BNC Connectors (Continued) Plugs 33.74 Max. [1.328] 14.61 Dia. [.575] Max. RG/U Cable 108, 108A Belden 9272, 89272 Center Contact Plating Silver Silver Body Plating Dielectric Integral Die Hand Tool Part No. Silver Nickel TEFLON Polypropylene 69667 69667 332225 332225-5 Silver Silver TEFLON 69667 332225-3 Silver Nickel Polypropylene 69667 332225-6 Trompeter TWC-124-2 ROLM 49D2401 Raychem 7824D013 Bulkhead Jack +0.13 12.83 -0.00 Dia. [.505 +.005 -.000 ] +0.13 11.05 -0.00 [.435 +.005 -.000 ] H 38.1 Max. [1.500] Maximum Panel Thickness 3.18 [.125] Recommended Panel Cutout H = 17.45 [.687] Max. across flats, 20.32 [.800] Max. across points 88 RG/U Cable Center Contact Plating Body Plating Dielectric CERTI-CRIMP Hand Tool with Integral Die Integral Die Hand Tool Die Insert for Tools: Hand Tool-69710-1, 626 Pneu. Head 318161-1 Part No. 108, 108A Belden 9272, 89272 Silver Silver TEFLON -5— 69667 69708 332342 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Twin BNC Connectors (Continued) Right-Angle PC Board/ Panel Mount Jacks 15.88 Mtg. [.625] Hgt. +0.13 12.83 -0.00 Dia. [.505 +.005 -.000 ] Material Body — VALOX, White Center Contacts — Gold Dielectric — Polymethylpentene 36.83 Max. [1.450] +0.08 5.54 -0.00 [.218 +.003 -.000 ] Maximum Panel Thickness 6.1 [.240] Recommended Panel Cutout With Mounting Posts Part No. 228686-1 2.01 ±0.05 [.079 ±.002] Dia. (2 Holes) 10.16 ±0.08 [.400 ±.003] 5.08 ±0.08 [.200 ±.003] 6.35 ±0.08 [.250 ±.003] 2.54 ±0.08 [.100 ±.003] 1.6 ±0.05 [.063 ±.002] 3.2 ±0.08 [.126 ±.003] 0.89 ±0.08 [.035 ±.003] Dia. (3 Holes) Recommended PC Board Layout +0.13 12.83 -0.00 Dia. [.505 +.005 -.000 ] Vertical PC Board/ Panel Mount Jacks +0.08 5.54 -0.00 [.218 +.003 -.000 ] 35.56 Mtg. [1.400] Hgt. Material Body — VALOX, White Center Contacts — Gold Dielectric — Polymethylpentene Maximum Panel Thickness 6.1 [.240] Recommended Panel Cutout With Mounting Posts Part No. 221198-1 3.2 ±0.13 [.126 ±.005] Lockwasher and Jam Nut 1.6 ±0.05 [.063 ±.002] 5.08 ±0.08 [.200 ±.003] 10.16 ±0.08 [.400 ±.003] Part No. 1-329632-2 0.89 ±0.05 [.035 ±.002] Dia. (3 Holes) 2.54 ±0.08 [.100 ±.003] Part No. 1-329631-2 2.01 ±0.05 [.079 ±.002] Dia. (2 Holes) 5.08 ±0.08 [.200 ±.003] 10.16 ±0.08 [.400 ±.003] Recommended PC Board Layout Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 89 Catalog 1307191 Revised 10-00 RF Coax Connectors Twin BNC Connectors (Continued) Vertical PC Board Mount Jack 10.16 ±0.08 [.400 ±.003] +0.13 12.83 -0.00 Dia. [.505 +.005 -.000 ] 2.01 ±0.05 Dia. [.079 ±.002] 2 Plcs. 5.08 ±0.08 [.200 ±.003] 0.89 ±0.05 Dia. [.035 ±.002] 2 Plcs. 1.17 ±0.08 Dia. [.046 ±.003] Plating Body — Nickel Center Contacts — Gold Dielectric — Polymethylpentene +0.08 5.54 -0.00 [.218 +.003 -.000 ] 3.48 ±0.08 [.137 ±.003] 3.20 ±0.13 [.126 ±.005] 10.16 ±0.08 [.400 ±.003] Part No. 415832-1 Recommended Panel Cutout PCB Configuration Plating Body — Tin-Lead Center Contacts — Gold Dielectric — TEFLON 22.17 [.873] 2.03 [.080] Dia. 6 Places 9.65 [.380] Dia. 3.20 [.126] 1.98 [.078] 6.22 [.245] 1.98 [.078] 6.22 [.245] Part No. 414287-1 Bulkhead Jack Adapter +0.13 12.83 -0.00 Dia. [.505 +.005 -.000 ] Plating Body — Silver Center Contacts — Silver 11.05 ±0.08 [.435 ±.003] 35.72 Max. [1.406] H Maximum Panel Thickness 3.18 [.125] H = 17.45 [.687] Max. across flats, 20.32 [.800] Max. across points Recommended Panel Cutout Part No. 332215 90 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors F Series and G Series Connectors Product Facts ■ Designs meet SCTE requirements where applicable ■ Plugs, jacks and adapters available ■ Board mount and cable mount available ■ Surface mount connectors available ■ Sealed product available ■ High current carrying capabilities AMP F Series connectors offer performance, which is driven by evolving OEM requirements and expectations. Improved VSWR beyond 1 GHz, high current carrying capability, and pressure sealed products are now part of the standard product offering. Designs compliant with SCTE, Bellcore, UL/CSA, and various other industry and agency standards are also available. Product Specification Instruction Sheets 108-1518 — Connector Coaxial, F Series, RF, Single Crimp Plug 108-1643 — Connector Coaxial, F Series, RF, PCB Mounted 108-1755 — Connector Economy, F Series, RF Coaxial, PCB 108-1757 — Connector, 15 amp, G Series Jack, PCB 108-1758 — Connector, F Series Jack, PCB, Surface Mount 108-1629 — Feedthrough, Sealed F Port Jack 408-9221 — Coaxial Series F Plug Connectors 408-4402 — Series F & G Coaxial Cable Bulkhead Jack Connector 408-4291 — Pro-Crimper II Hand Tool Assembly 58622-1 and 58622-2 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Both cable applied and PCB terminated products are offered in a variety of styles. The cable connectors are designed for fast, accurate termination with tools common to the industry. Application cost reductions can be achieved using AMP PCB terminated products; press-fit designs eliminate the need for soldering. Center of gravity control and PCB retention designs prevent tipping and eliminate fixturing during soldering. Integral mechanical keys and “D flats” prevent rotation in panels. These products provide the highly reliable, cost-effective solutions demanded by today’s evolving marketplace. www.amp.com/communications/com Specifications subject to change. 91 Catalog 1307191 Revised 10-00 RF Coax Connectors F Series Connectors Plugs Crimp Style A 21.59 Max. [.850] Screw-On Style B Crimp Style, Hex C RG/U Cable Termination Type Body Plating Style “B” Threads PRO-CRIMPER† Hand Tool Assembly 58425-3, 58436-2, or 58621-2 58425-3, 58436-2, or 58621-2 59 Crimp Nickel A — 6 Crimp Nickel A 221539-2 1/4-20 UNC-2B M7x1 — — 221540-1 — 221540-2 414766-1 414766-2 59 Screw-On Nickel B 6 59 Belden 9104, 9100 Screw-On Nickel B Crimp Nickel C — 58425-3, 58436-2, or 58621-2 6 Crimp Nickel C — 59 Crimp Nickel C — 58425-3, 58436-2, or 58621-2 58425-3, 58436-2, or 58621-2 Part No. 221539-1 414766-8 † 8.23 [.324] Hex Crimp RG/U Cable Termination Type Center Contact Plating Body Plating 179 Crimp Tin-Lead Nickel 179 Double Braid Crimp Tin-Lead Nickel Termination Tooling Part No. Braid: M 22520/5-01 w/ Daniels Die Set Hx4-1637 (.128 Hex) Contact: M 22520/2-01 w/ Daniels Positioner K727, Pos. 2 Braid: M 22520/5-01 w/ Daniels Die Set Hx4-1637 (.151 Hex) or 58425-3 Die Set for Pro-Crimper (.151 Hex) Contact: M 22520/2-01 w/ Daniels Positioner K727, Pos. 2 Right Angle Plugs, Crimp 415226-1 415226-2 39.11 ± 0.20 [1.540 ± .008] 10.50 ± 0.20 [.413 ± .008] 9.40 [.370] 1.50 ± 0.30 [.059 ± .012] RG/U Cable 6 Std. Cable 92 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Termination Type Center Contact Plating Body Plating Termination Tooling Part No. Crimp Tin Nickel use .324 inch Hex 887098-1 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors F Series Connectors (Continued) Bulkhead Jacks, Crimp Front Mount Style A RG/U Cable 179 179 Center Contact Plating Bright Tin-lead Bright Tin-lead Rear Mount Style B Style Body Plating Die Set Part No. A Nickel 220210-1** 415710-1 B Nickel 220210-1** 415712-1 **use with hand tool 354940-1 Bulkhead Jacks, Crimp, Splash Resistant Front Mount Style A RG/U Cable 179 179 Center Contact Plating Bright Tin-lead Bright Tin-lead Rear Mount Style B Style Body Plating Die Set Part No. A Nickel 220210-1** 415569-2 B Nickel 220210-1** 415711-1 **use with hand tool 354940-1 Bulkhead Jack, Crimp, Sealed Part No. 415436-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] For use with RD 179 (double braid). PRO-CRIMPER II acceptable mating pin range .022-.042. Contact crimp tooling, use hand tool part number 318450-1, which includes frame part number 354940-1 and die set part number 318450-2. Ferrule crimp tooling, use Certi-Crimp hand tool 220009-1 www.amp.com/communications/com Specifications subject to change. 93 Catalog 1307191 Revised 10-00 RF Coax Connectors F Series Connectors (Continued) Bulkhead Jack, PC Board 5.60 [.220] 11.2 ± 0.1 [.441 ± .004] 3.30 [.130] 20.8 [.820] Ø 12.70 ± 0.1 [.500 ± .004] Part No. 1274085-1 Right Angle PC Board Mount Jacks 4.11 ± 0.08 [.162 ± .003] + 0.13 9.65 – 0.00 .005 ] [.380 +– .000 Dia. 2.50 ± 0.08 [.098 ± .003] 4 Plcs. 0.99 ± 0.08 [.039 ± .003] 8.20 ± 0.08 [.323 ± .003] A B Recommended Panel Cutout C Body Plating Barrel Base Center Contact Plating Nickel Tin-lead Tin-lead Nickel Tin-lead Tin-lead Nickel Tin-lead Tin-lead PC Board Layout A 26.26 1.034 25.40 1.00 31.75 1.250 Dia. .005 ] [.350 +– .000 C 16.76 .660 15.90 .626 22.25 .876 4.11 ± 0.08 [.162 ± .003] + 0.13 8.89 – 0.00 + 0.13 9.65 – 0.00 .005 ] [.380 +– .000 Dimensions B 17.91 .705 14.48 .570 14.48 .570 Part No. 415476-1 415302-1 415302-2 2.50 ± 0.08 [.098 ± .003] 4 Plcs. 0.99 ± 0.08 [.039 ± .003] A B 8.20 ± 0.08 [.323 ± .003] Recommended Panel Cutout C *Connectors willl accept a center conductor, diameter of 0.51-1.19 [.020-.047] 94 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Body Plating Barrel Base Nickel Tin-lead Center Contact Plating Tin-lead Dimensions are in millimeters over [inches] PC Board Layout A 29.97 1.180 Dimensions B 17.53 .690 www.amp.com/communications/com C 12.19 .480 Part No. 887078-1 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors F Series Connectors (Continued) Right Angle PC Board Mount Jacks (Continued) + 0.13 8.03 – 0.00 2.26 ± 0.08 [.089 ± .003] 4 Plcs. 0.99 ± 0.08 [.039 ± .003] + 0.13 9.65 – 0.00 .005 ] [.380 +– .000 Dia. .005 ] [.316 +– .000 9.14 ± 0.08 [.360 ± .003] 4.57 ± 0.08 [.180 ± .003] B 5.77 ± 0.08 [.227 ± .003] A Recommended Panel Cutout Body Plating Barrel Base C Nickel Tin-lead PC Board Layout Center Contact Plating Dimensions B 15.75 .620 A 33.81 1.331 Tin-lead C 19.86 .782 Part No. 415276-2* *Connector will accept center conductor diameter range of 0.56-1.19 [.022-.047]. Right Angle PC Board Mount Jack, High Temperature 4.11 ± 0.08 [.162 ± .003] + 0.13 8.89 – 0.00 [.350 +– .005 .000] 2.50 ± 0.08 [.098 ± .003] 4 Plcs. 0.99 ± 0.08 [.039 ± .003] + 0.13 9.65 – 0.00 8.20 ± 0.08 [.323 ± .003] .005 ] [.380 +– .000 Dia. *High temperature versions use PTFE dielectric (see table) Recommended Panel Cutout A PC Board Layout B C Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Bottom Dielectric Middle Front Solder Post Plating Acetal Acetal Polypropylene Nickel PTFE PTFE PTFE Nickel Acetal Acetal Polypropylene Tin-lead PTFE PTFE PTFE Tin-lead Dimensions are in millimeters over [inches] A 35.61 1.402 35.61 1.402 35.61 1.402 25.40 1.00 Dimensions B 16.89 .665 16.89 .665 16.89 .665 17.91 .705 www.amp.com/communications/com C 26.11 1.028 26.11 1.028 26.11 1.028 14.99 .590 Part No. 415024-1 415024-2 415024-3 415214-1 Specifications subject to change. 95 Catalog 1307191 Revised 10-00 RF Coax Connectors F Series Connectors (Continued) 15.88 [.625] Surface Mount, Straddle Jack 1.78 [.070] 1.91 [.075] 2 Plcs. Contact will accept center conductor diameter range 0.56–1.19 [.022–.047] Center of gravity balanced for automated pick and place and anti-tipping during solder reflow process. Tin-lead plated body to facilitate soldering process. 9.40 Typ. [.370] 18.29 0.76 [.720] [.030] Typ. 12.95 R 1.27 [.050] 14.61 [.575] 1.65 [.065] [.510] 13.21 [.520] Part No. 1274323-1 PC Board Layout Vertical PC Board Mount Jacks 9.50 [.374] + 0.13 9.65 – 0.00 .005 ] [.380 +– .000 A Dia. 4.32 ± 0.08 [.170 ± .003] 2.77 ± 0.08 [.109 ± .003] 4 Plcs. 1.22 ± 0.08 [.048 ± .003] Connector will accept a center conductor diameter of 0.56–1.19 [.022–.047] Tin-lead plated body to facilitate soldering process. 16.0 [.630] 8.64 ± 0.08 [.340 ± .003] 4.32 ± 0.08 [.170 ± .003] (splash resistant)(Dim A = .920) 8.64 ± 0.08 [.340 ± .003] Recommended Panel Cutout PC Board Layout Dim. A .930 .920 Notes — splash resistant Part No. 887046-1 1274423-1 36.45 [1.43] 8.64 [.340] 1.07 ± 0.05 [.042 ± .002] 4 Plcs. 13.49 [.531] 9.50 Sq. [.374] 4.32 Typ. [.170] 2.36 4 Plcs. [.093] 1.37 [.054] 8.64 [.340] Typ. 8.64 ± 0.08 Typ. [.340 ± .003] Part No. 1274020-1 4.32 [.170] PC Board Layout Adapters Jack to Jack High Performance Feed through Adapter Part No. 282933-2 96 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Jack to Jack Feed through Adapter Jack to Plug Right-Angle Adapter Part No. 282938-2 www.amp.com/communications/com Part No. 887089-1 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors G Series Connectors Bulkhead Jack, Crimp RG/U Cable 179 Conformable Cable RD 179 Double Braid Termination Type Crimp Body Plating Nickel 415683-1 Crimp Nickel 415683-2 Crimp Nickel 415683-3 Part No. Termination Tooling: Use 220210-1 die set for Contact only. Use Certi-Crimp Hand Tool 220009-1 for ferrule. Bulkhead Jack, PC Board 9.73 – 9.58 [.383 – .377] Connector will accept center conductor diameter range 0.97–1.65 [.038–.065] (415332-1 only) 8.15 – 8.00 [.321 –.315] Part No. 415332-1 (15 Amp) Part No. 415888-1 Part No. 1274032-1 9.73 – 9.58 [.383 – .377] Recommended Panel Cutout for 415332-1 and 415888-1 Bulkhead Jack, PC Board, Sealed 3.81 [.150] Recommended Panel Cutout for 1274032-1 8.51 ± 0.08 [.335 ± .003] 11.00 [.433] 1.02 [.040] 9.53 ± 0.08 [.375 ± .003] 14.40 [.567] 7.62 [.300] 1.52 [.060] Part No. 1274064-1 Jack, Bulkhead PC Board Connector will accept center conductor diameter range 0.97–1.07 [.038–.042] Part No. 887000-1 30.73 [1.210] Right Angle PC Board Mount Jack with Louvertac Band 9.50 [.374] 8.64 [.340] 4.32 [.170] Ø 9.27 [.365] Ø 1.02 [.040] 12.45 [.490] Ø 2.77 4 Plcs. [.109] Part No. 1274401-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 97 Catalog 1307191 Revised 10-00 RF Coax Connectors G Series Connectors (Continued) Right Angle PC Board Mount Plug 1.37 ± 0.08 [.054 ± .003] Includes board retention feature to prevent tipping during solder process. Tin-lead plated body to facilitate soldering process. 0.89 ± 0.08 [.035 ± .003] 1.93 ± 0.08 [.076 ± .003] 4 Plcs. 4.57 ± 0.08 [.180 ± .003] 9.14 ± 0.08 [.360 ± .003] 10.29 ± 0.08 [.405 ± .003] Part No. 415406-2 PC Board Layout Vertical PC Board Mount Plug 3.81 Typ. [.150] 2.03 [.080] Typ. 7.62 [.300] Typ. 7.62 Typ. [.300] 1.32 [.052] Typ. 2.08 [.082] 4 Plcs. 1.27 [.050] PC Board Layout Part No. 1274045-1 Adapters F Jack to G Jack Bulkhead Adapter Sealed F Jack to G Jack Bulkhead Adapter 9.65 + 0.13 – 0.00 [.380 + .005] – .000 Dia. Recommended Panel Cutout Part No. 415327-1 Part No. 887058-1 F Jack to G Plug Bulkhead Adapter 11.30 [.445] Connector will accept center conductor diameter range of 0.51–1.19 [.020–.047]. Panel nut 887003-3 available for float mounting. 12.95 [.510] Part No. 415523-1 98 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Recommended Panel Cutout www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors Product Facts ■ Performance to 12.4 GHz ■ Available in various base metal options, including stainless steel, brass and zinc diecast ■ Uses industry standard crimp tools and processes ■ Available with corrosion resistant, non-magnetic White Bronze plating ■ Meets all performance requirements for MIL-C-39012. AMP offers a complete line of SMA connectors designed for performance to 18 GHz to satisfy the growing demand for SMA connectors in the wireless communications industry. The SMA product line offers stainless steel bodies, as well as non-ferrous metals. Various plating options are available, including Gold and White Bronze. The SMA interface is fully compatible with Mil-C-39012. While still offering various options on military (QPL) approved connectors, AMP has developed a complete offering tailored to the commercial Communications industry. This includes 3 piece flexible cable products for popular RG 316, 142 and RD 316 cable utilizing industry standard HEX crimps. The SMA series meets the performance, quality and application requirements of the commercial marketplace. This includes White Bronze plating, a unique finish developed by AMP to address the performance needs of the telecommunications market. This plating is highly resistant to wear, and contains no ferrous metals, thus displaying excellent intermodulation characteristics. To satisfy the broad range of commercial applications, SMA connectors are available in a broad range of standard configurations including; straight and right angle cable applied plugs, bulkhead cable jacks, two and four hole flange mount panel jacks, straight and right angle pcb mount jacks and various between and in series adapters. Numerous packaging and testing options are also available to meet specific system criteria as well. Additionally, standard military approved (QPL) interfaces are offered as well. Including connectors for semi-rigid cable and micro strip applications. The 3 Piece SMA offering is designed especially for applications in cellular infrastructure where InterModulation Products (IMP) must be minimized. By limiting non-linearities within the connectors, IMP is reduced and increased channel capacity can be offered. Between Series Adapters For SMA Between Series Adapters, see Pages 255-264. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 99 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Specifications MIL-C-39012 Applicable Paragraph General Material 3.3 Finish 3.3.1 Design 3.4 Steel corrosion resistant per ASTM-A-582 and ASTM-A-484, Type 303. Beryllium copper per ASTM-B-196. PTFE Fluorocarbon per ASTM-D-1457. Center contacts shall be gold plated to a min. thickness of .00127 [.00005] in accordance with MIL-G-45204, Type I, Grade C. All other metal parts shall be finished as to provide a connector which meets the corrosion requirements. The design shall be such that the outline shown in this catalog and the interface dimensions of MIL-STD-348A are met. Electrical Insulation Resistance Corona Level Dielectric Withstanding Voltage RF High Potential Contact Resistance VSWR 3.11 3.22 3.17 3.23 3.16 3.14 RF Leakage Insertion Loss 3.26 3.27 The insulation resistance shall not be less than 10,000 megohms. Refer to applicable military slash sheet or consult factory. Refer to applicable military slash sheet or consult factory. Refer to applicable military slash sheet or consult factory. Refer to applicable military slash sheet or consult factory. Refer to applicable military slash sheet or consult factory. Frequency range dependent on cable used. Refer to applicable military slash sheet or consult factory. Refer to applicable military slash sheet or consult factory. Frequency range dependent on cable used. Mechanical Force to Engage 3.5.1 Coupling Nut Retention Coupling Proof Torque Cable Retention Mating Characteristics 3.25 3.6 3.24 3.7 Connector Durability 3.15 Recommended Mating Torque — The torque required to engage and disengage shall not exceed 2 in.-lbs. The longitudinal force is not applicable. 60 lbs. min. Applicable for plug connectors only. 15 in.-lbs. min. Applicable for plug connectors only. Refer to applicable military slash sheet or consult factory. Applicable to jack connectors only. Reference MIL-STD-348A for dimensions; oversize test pin .953 [.0375] min. dia., .76 - 1.14 [.030-.045] deep, insertion force 3 lbs. max. with .940 [.0370] min. dia. pin, withdrawal force 1 oz. min. with .902 [.0355] max. dia. pin. The connector to be tested and its mating connector shall be subjected to 500 insertion and withdrawal cycles at 12 cycles per minute max. The connector shall show no evidence of mechanical failure and shall meet the mating characteristic requirements. 7 to 10 in.-lbs. Environmental Vibration Shock Thermal Shock Corrosion (Salt Spray) Moisture Resistance White Bronze Plating AMPs unique Copper, Tin, Zinc alloy finish is a robust plating which is suitable for applications requiring excellent levels of electrical performance and offers the following attributes: ■ ■ 100 High Corrosion Resistance Low Porosity 3.18 3.19 3.20 3.13 3.21 Specification MIL-STD-202, method 204, test condition D Specification MIL-STD-202, method 213, test condition I Refer to applicable military slash sheet or consult factory. Specification MIL-STD-202, method 101, test condition B. Specification MIL-STD-202, method 106. No measurements at high humidity. Insulation resistance shall be at least 200 megohms within 5 minutes of removal from humidity. Non-Magnetic Finish Wear and Scratch Resistant ■ Low RF Losses ■ Excellent for Intermodulation Sensitive Applications ■ ■ For more information on White Bronze Plating, see the Application Note in the Appendix. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Intermodulation Dissimilar metals, finishes and discontinuities within a coax line structure give rise to intermodulation distortion (IMD). This is of particular concern in applications such as cellular base stations and antennas which require low levels of intermodulation. SMA connectors were designed with this phenomena in mind and, as such, contain no ferrous or magnetic materials and utilize low porosity White Bronze plating. For more information on Intermodulation, see the Application Note in the Appendix. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Electrical Connector Type Cable Straight Cable Plug without Contact RG-402 (3.58 [.141]) Straight Cable Plugs & Jacks Solder Attachment Straight Cable Plugs & Jacks Solder Clamp Attachment Frequency VSWR Max. x (fGHz) (GHz) Corona Contact Resistance Insulation Dielectric RF (milliohms max.) Resistance Withstanding Extinction Voltage at Transmission Voltage Center Outer (megohms 70,000 Ft. Loss min.) (Volts RMS) (V RMS min.) Contact Contact Note 1 1.02 + .005 N/A 2.0 10,000 N/A 250 1.10 + .005 2.0 2.0 10,000 1000 250 RG-405 (2.16 [.085]) 12.4 1.10 + .015 2.0 2.0 10,000 1000 250 RG-402 (3.58 [.141]) 12.4 1.07 + .01 2.0 2.0 10,000 1500 375 Note 1 1.10 + .005 2.0 2.0 10,000 1000 250 Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 18.0 18.0 18.0 18.0 12.4 18.0 12.4 18.0 1.15 + .01 — 1.10 + .005 1.10 + .005 1.15 + .01 — 1.2 + .02 1.07 + .01 1.07 + .01 1.07 + .01 1.07 + .01 1.18 + .015 1.18 + .015 1.15 + .015 1.10 + .010 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 10,000 750 750 1000 1000 750 750 500 1500 1500 1500 1500 1000 1000 1500 1500 190 190 250 250 190 190 125 375 375 375 375 250 250 325 250 Note 1 1.15 + .01 2.0 2.0 10,000 1000 250 Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 1.15 + .02 1.15 + .02 1.15 + .02 1.18 + .02 — 1.25 + .025 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 10,000 10,000 10,000 10,000 10,000 10,000 750 1000 1000 750 750 500 190 250 250 190 190 125 Note 1 1.10 + .005 2.0 2.0 10,000 1000 250 Note 1 Note 1 18.0 18.0 18.0 1.15 + .01 — 1.03 + .004 1.05 + .005 1.04 + .004 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 10,000 10,000 10,000 10,000 10,000 750 750 1000 1000 1000 190 190 250 250 250 18.0 1.04 + .006 2.0 2.0 10,000 1000 250 18.0 18.0 18.0 12.4 1.07 + .010 1.07 + .010 1.07 + .015 1.15 + .015 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 10,000 10,000 10,000 10,000 1000 1000 1000 1000 250 250 250 250 N/A .03 √-f(GHz) .03 √-f(GHz) .03 √-f(GHz) .03 √-f(GHz) .06 √-f(GHz) .06 √-f(GHz) .03 √-f(GHz) .03 √-f(GHz) .06 √-f(GHz) .06 √-f(GHz) — .06 √-f(GHz) .06 √-f(GHz) .06 √-f(GHz) — .06 √-f(GHz) .05 √-f(GHz) .05 √-f(GHz) .05 √-f(GHz) .05 √-f(GHz) .04 √-f(GHz) .04 √-f(GHz) .04 √-f(GHz) .05 √-f(GHz) .07 √-f(GHz) .07 √-f(GHz) .07 √-f(GHz) .07 √-f(GHz) .07 √-f(GHz) — .07 √-f(GHz) .08 √-f(GHz) .08 √-f(GHz) — .03 √-f(GHz) .03 √-f(GHz) .03 √-f(GHz) .04 √-f(GHz) .04 √-f(GHz) .04 √-f(GHz) .08 √-f(GHz) .08 √-f(GHz) RG-405 (2.16 [.085]) 18.0 RG-402 (3.58 [.141]) 18.0 3.58 [.141] Microporous 18.0 RG-401 (6.35 [.250]) 18.0 RG-174, 188, 316 Note 1 RG-55, 58, 141, 142, Note 1 223, 303, 400 1.05 + .005 1.05 + .005 1.05 + .005 1.07 + .007 1.15 + .01 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 10,000 10,000 10,000 10,000 10,000 1000 1500 1500 1500 750 250 375 375 375 190 18.0 N/A 2.0 2.0 10,000 1000 250 12.4 N/A 2.0 2.0 10,000 1000 RG-55, 58, 141, 142 223, 400 RG-174, 188, 316 RG-180, 195 RG-55, 142, 223, 400 RG-58, 141, 303 Straight Cable Plugs & Jacks Crimp RG-174, 188, 316 Attachment RG-180, 195 RG-178, 196 RG-401 (6.35 [.250]) Straight Cable Plugs 6.35 [.250] Microporous & Jacks Compression 6.35 [.250] 3 Spline Clamp Attachment 6.35 [.250] 5 Spline RG-405 (2.16 [.085]) RG-405 (2.16 [.085]) RG-402 (3.58 [.141]) Right Angle Cable Plugs Solder RG-402 (3.58 [.141]) Attachment RG-55, 58, 141, 142, 223, 303, 400 RG-174, 188, 316 RG-55, 142, 223, 400 RG-58, 141, 303 Right Angle Cable Plugs Crimp RG-174, 188, 316 Attachment RG-180, 195 RG-178, 196 RG-55, 58, 141, 142, Right Angle Cable 223, 303 Plugs Clamp RG-174, 188, 316 Attachment RG-180, 195 Non-Captured Epoxy Captured Flange Mount Plugs & Jacks Panel or Mechanical Capture Bulkhead Mount Field Replaceable Hermetic Launchers Epoxy Captured Bulkhead Feedthrough Jacks Mechanical Capture N/A Right Angle Flange Mount Jacks N/A Printed Circuit Board N/A Mount Straight Terminal Right Angle N/A Printed Circuit End Launch N/A Stripline Circuit Surface Launch N/A Stripline Circuit N/A Right Angle Surface Launch Stripline Circuit N/A Straight Cable Plugs & Jacks Clamp Attachment 18.0 1.05 + .005 2.0 2.0 10,000 1000 RF High RF Potential Leakage at 5 MHz (dB min.) (V RMS) 670 -(90-fGHz) 670 1000 1000 1000 500 -(90-fGHz) -(90-fGHz) -(90-fGHz) -(90-fGHz) -(60-fGHz) 670 -(60-fGHz) 670 -(90-fGHz) 1000 -(90-fGHz) 670 -(60-fGHz) 500 500 670 670 500 500 335 1000 1000 1000 1000 670 670 1000 1000 -(60-fGHz) -(60-fGHz) -(60-fGHz) -(60-fGHz) -(60-fGHz) -(60-fGHz) -(60-fGHz) -70 dB min. -70 dB min. -70 dB min. -70 dB min. -(90-fGHz) -(90-fGHz) -(90-fGHz) -(90-fGHz) 670 -(60-fGHz) 500 670 670 500 500 335 -(60-fGHz) -(60-fGHz) -(60-fGHz) -(60-fGHz) -(60-fGHz) -(60-fGHz) 670 -(60-fGHz) 500 500 670 670 670 -(60-fGHz) -(60-fGHz) -(100-fGHz) -(60-fGHz) -(100-fGHz) 670 -(100-fGHz) 670 670 670 670 -(60-fGHz) -(100-fGHz) -(90-fGHz) -(90-fGHz) N/A 670 N/A 250 N/A 670 N/A 250 .03 √-f(GHz) 670 -(60-fGHz) .03 √-f(GHz) .08 √-f(GHz) .08 √-f(GHz) 670 -(60-fGHz) 670 670 -(60-fGHz) -(60-fGHz) 18.0 1.05 + .005 2.0 2.0 10,000 1000 250 12.4 18.0 1.15 + .015 1.07 + .015 2.0 2.0 2.0 2.0 10,000 10,000 1000 1000 250 250 1. Maximum operating frequency of cable per MIL-C-17. 2. Specifications do not apply to hermetic or compression crimp connectors. 3. For Brass SMA: Frequency Range DC-6GHz, Impedance 50 Ohms, Insulation Resistance. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 101 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Interface Mating Dimensions F D G Dia. Ref. Plane Note 2 C Ref. Plane Note 2 C H Dia. B Dia. Plug B .250-36 UNS-2A Thd. D A B Dia. Dia. A Dia. E D G Dia. F G .250-36 UNS-2B Thd. E J Dia. H K H Dia. Plug A Plug Jack Dimension Minimum 6.35 .250 Maximum Dimension A — A B — B C — D 0.00 .000 4.59 .1808 3.43 .135 0.25 .010 2.54 .100 0.25 .010 0.94 .037 0.38 .015 E — F 0.00 .000 0.90 .0355 0.00 .000 G H C D E F G H J K Minimum 5.28 .208 4.60 .181 1.91 .075 0.00 .000 0.38 .015 2.92 .115 0.00 .000 4.32 .170 .124 .049 5.54 .218 Maximum 5.49 .216 — 1.98 .078 0.25 .010 1.43 .045 — 0.25 .010 — 1.30 .051 — Notes: 1. ID to meet VSWR and contact resistance when mated with 0.51 +.025/-.013 [.036 +.0010/-.0005] Dia. Pin. 2. When fully engaged, the two reference planes must coincide with metal to metal contact. 3. Metric equivalents (to the nearest 0.01mm) are given for general information only. 102 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Direct Solder Attachment, Semi-Rigid Cable Straight Cable Plug 5.4 Ref. [.213] Ø 3.66 [.144] 8.40 [.330] Solder M/A-COM Contact Contact Part Kit Instruction Model Captivation Attachment Assembly Sheet No. Part No. No. No Center No Center 402 (3.58 [.141]) Stainless, Pass. Contact 1055420-1 408-4761 2001-7941-02 1050757-1 Contact Cable Type RG/U Body Material & Finish Straight Cable Plug Ø 3.67 [.144] RG402/U Ø 2.26 [.089] RG405/U 8.1 Ref. [.320] 11.2 [.440] Ref. Cable Type RG/U Body Material & Finish 402 (3.58 [.141]) Stainless, Gold1 405 (2.16 [.085]) Stainless, Gold1 405 (2.16 [.085]) Brass, Gold 402 (3.58 [.141]) Stainless, Gold1 405 (2.16 [.085]) Stainless, Gold1 Ø 4.6 [.180] Solder Contact Contact Kit Captivation Attachment Assembly Part No. No Solder 1055420-1 No Solder 1055420-1 No Solder 1055420-1 No Center No Center N/A Contact Contact No Solder 1055420-1 M/A-COM Part Model No. No. 408-4764 2001-5003-02 1050525-1 408-4765 2001-7985-02 1050770-1 408-4765 2201-7985-09 1091921-1 Instruction Sheet — 2001-5031-02 1050542-1 — 2001-5032-02 1050548-1 Coupling nut is passivated stainless steel. 1 Straight Cable Jack 12.7 [.500] Ø 3.66 [.144] RG402/U Ø 2.26 [.089] RG405/U 10.8 Ref. [.424] Solder M/A-COM Contact Contact Part Kit Instruction Model Captivation Attachment Assembly Sheet No. Part No. No. 402 (3.58 [.141]) Stainless, Gold No Solder 1055420-1 408-4767 2002-5015-00 1050854-1 405 (2.16 [.085]) Stainless, Gold No Solder 1055420-1 408-4833 2002-5016-00 1050859-1 Cable Type RG/U Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Body Material & Finish Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 103 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Direct Solder Attachment, Semi-Rigid Cable (Continued) Bulkhead Cable Jack 19.0 [.748] 12.7 [.500] 10.5 [.415] Ø 3.66 [.144] RG402/U Ø 2.26 [.089] RG405/U 8.6 [.339] Ref. 6.0 Min. [.235] Ø 6.4 Min. [.250] Ø 4.6 [.180] 2.4 Max [.093] Panel Cable Type RG/U Body Material & Finish 402 (3.58 [.141]) Brass, Gold 2 Hole Flange Mount Cable Jack Recommended Mounting Hole Solder M/A-COM Contact Contact Part Kit Instruction Model Captivation Attachment Assembly Sheet No. Part No. No. No Solder 1055420-1 408-4768 2204-7941-09 1082029-1 14.2 [.560] 9.5 [.375] 7.6 Ref. [.299] 5.7 [.223] 1.7 [.065] Ø 3.66 [.144] RG402/U Ø 2.26 [.089] RG405/U 12.2 [.481] Ø 15.9 [.625] .250-36 UNS-2A Ø 2.6 2 Plcs. [.102] Solder M/A-COM Contact Contact Part Kit Instruction Model Captivation Attachment Assembly Sheet No. Part No. No. 402 (3.58 [.141]) Stainless, Gold No Solder 1055420-1 408-4767 2006-5013-00 1051052-1 405 (2.16 [.085]) Stainless, Gold No Solder 1055420-1 408-4883 2006-5010-00 1051046-1 Cable Type RG/U 4 Hole Flange Mount Cable Jack Body Material & Finish Ø 3.66 [.144] RG402/U Ø 2.26 [.089] RG405/U 7.6 Ref. [.299] Ø 2.6 4 Plcs. [.102] 8.6 2 Plcs. [.340] 9.5 [.375] 14.2 [.560] 12.7 Sq. [.500] Solder M/A-COM Contact Contact Part Kit Instruction Model Captivation Attachment Assembly Sheet No. Part No. No. 402 (3.58 [.141]) Stainless, Gold No Solder 1055420-1 408-4767 2006-7941-00 1051081-1 405 (2.16 [.085]) Stainless, Gold No Solder 1055420-1 408-4883 2006-7985-00 1051085-1 Cable Type RG/U 104 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Body Material & Finish Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Semi-Rigid Cable Right Angle Cable Plug, Direct Solder Attachment 17.1 [.675] Ref. 13.6 [.535] Ref. Ref. Plane 10.5 [.413] Ref. 7.9 [.312] Ref. 7.9 [.312] Hex. Ø 3.66 [.144] RG402/U Ø 2.26 [.089] RG405/U Solder Contact Contact Kit Captivation Attachment Assembly Part No. 1 402 (3.58 [.141]) Stainless, Gold Epoxy Solder 1055420-1 405 (2.16 [.085]) Stainless, Gold1 Epoxy Solder 1055420-1 402 (3.58 [.141]) Brass, Gold Mechanical Solder 1055420-1 405 (2.16 [.085]) Brass, Gold Mechanical Solder 1055420-1 Cable Type RG/U Body Material & Finish Instruction Sheet 408-4831 408-4831 408-4831 408-4831 M/A-COM Model No. 2007-7941-02 2007-7985-02 2207-7941-09 2207-7985-09 Part No. 1051151-1 1051157-1 1082030-1 1088312-1 Coupling nut is passivated stainless steel. 1 Straight Cable Plug, Crimp 13.5 [.530] Max. 9.8 Ref. [.387] 6.9 [.270] RG402/U Ref 7.1 [.278] RG405/U 10.9 [.430] Ref. Ø 3.63 [.143] RG402/U Ø 2.26 [.089] RG405/U Crimp Tooling Part No. 405 (2.16 [.085]) Stainless, Pass. Mechanical Solderless 1055835-1 Center Solderless 1055835-1 402 (3.58 [.141]) Stainless, Pass. No Contact 405 (2.16 [.085]) Stainless, Pass. Mechanical Solderless 1055835-1 Body Material & Finish Straight Cable Plug — Low Profile, Crimp Contact Captivation 5.8 Ref. [.229] 5.50 Dia. [.218] Part No. 1050742-1 Part No. 1050598-1 and 1050740-1 Cable Type RG/U 3.60 Dia. [.143] Contact Attachment M/A-COM Part Model No. No. 408-4695 2001-5385-02 1050598-1 Instruction Sheet 408-4690 2001-7641-02 1050740-1 408-4690 2001-7642-02 1050742-1 Ø 3.66 [.144] RG402/U Ø 2.26 [.089] RG405/U 8.6 Ref. [.337] Cable Type RG/U Body Material & Finish Contact Captivation Contact Attachment Crimp Tooling Part No. Center No Center 1055835-1 402 (3.58 [.141]) Stainless, Pass. No Contact Contact 402 (3.58 [.141]) Stainless, Pass. Mechanical Solderless 1055835-1 405 (2.16 [.085]) Stainless, Pass. Mechanical Solderless 1055835-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Instruction Sheet M/A-COM Model No. Part No. 408-4693 2001-5363-02 1050591-1 408-4696 2001-5395-02 1050602-1 408-4697 2001-5443-02 1050611-1 www.amp.com/communications/com Specifications subject to change. 105 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Semi-Rigid Cable Straight Cable Jack, Crimp 15.39 [.606] Ref. After Crimping Ref. Plane 6.4 [.250] Hex. 13.46 [.530] After Crimping Ø 3.63 [.143] RG402/U Ø 2.26 [.089] RG405/U .250-36, UNS-2A Crimp Tooling Part No. 402 (3.58 [.141]) Stainless, Pass. Mechanical Solderless 1055835-1 405 (2.16 [.085]) Stainless, Pass. Mechanical Solderless 1055835-1 Cable Type RG/U Body Material & Finish Contact Captivation Contact Attachment 2 Hole Flange, Crimp Ø 3.63 [.143] RG402/U Ø 2.26 [.089] RG405/U 10.5 [.415] 6.0 [.235] Ø 6.4 Min. [.250] 14.7 Ref. [.579] 16.7 Ref. [.657] Recommended Mounting Hole Crimp Tooling Part No. 402 (3.58 [.141]) Stainless, Pass. Mechanical Solderless 1055835-1 405 (2.16 [.085]) Stainless, Pass. Mechanical Solderless 1055835-1 Cable Type RG/U Body Material & Finish Contact Captivation Right Angle Cable Plug, Crimp M/A-COM Part Model No. No. 408-4687 2002-7641-02 1050909-1 408-4688 2002-7685-02 1050911-1 Instruction Sheet Contact Attachment M/A-COM Part Model No. No. 408-4954 2004-7641-02 1051005-1 408-4689 2004-7685-02 1051007-1 Instruction Sheet 15.8 [.622] Ref. 12.6 [.497] Ref. 9.7 [.383] Ref. Ref. Plane 14.43 [.568] After Crimping 7.9 [.312] Hex. Ø 3.63 [.143] RG402/U Ø 2.26 [.089] RG405/U 11.25 [.443] Ref. After Crimping Crimp Tooling Part No. 402 (3.58 [.141]) Stainless, Pass. Mechanical Solderless 1055835-1 405 (2.16 [.085]) Stainless, Pass. Mechanical Solderless 1055835-1 Cable Type RG/U 106 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Body Material & Finish Contact Captivation Dimensions are in millimeters over [inches] Contact Attachment M/A-COM Part Model No. No. 408-4691 2007-7641-02 1051145-1 408-4692 2007-7685-02 1051147-1 Instruction Sheet www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Flexible Cable Straight Cable Plug, Solder 30.2 Ref. [1.187] A 7.9 [.312] Hex. Cable Type RG/U Body Material & Finish Contact Captivation Contact Attachment Dimension A No Solder No Solder 19.7 .775 17.5 .690 55, 58, 141, 142, Stainless, Gold1 223, 303, 400 174, 188, 316 Heat Shrink Tubing 16.7 [.658] Ref. Ref. Plane Stainless, Gold1 Instruction Sheet M/A-COM Model No. Part No. 408-4821 2031-5002-02 1051638-1 408-4756 2031-5003-02 1051644-1 Coupling nut is passivated stainless steel. 1 Straight Cable Jack, Solder 25.6 Ref. [1.007] A 16.6 [.654] Ref. Ref. Plane .250-36 UNS-2A Heat Shrink Tubing 6.4 [.250] Hex. Cable Type RG/U Body Material & Finish Contact Captivation Contact Attachment Dimension A No Solder 18.5 .730 55, 58, 141, 142, Stainless, Gold 223, 303, 400 Bulkhead Cable Jack, Solder Instruction Sheet M/A-COM Model No. Part No. 408-4820 2032-5002-00 1051852-1 31.10 [1.225] Ref. A 11.4 [.450] 9.50 [.374] Ref. Ref. Plane .250-36 UNS-2A 7.9 [.312] Hex. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Ø 6.4 [.250] Min. 3.2 Max. [.125] Panel Recommended Mounting Hole Cable Type RG/U Body Material & Finish Contact Captivation Contact Attachment Dimension A RG 55, 58, 141, 142, 300 Stainless, Gold No Solder 174, 188, 316 Stainless, Gold No Solder 24.0 .945 21.0 .825 Dimensions are in millimeters over [inches] 6.0 Min. [.235] Shrink Tubing Instruction Sheet M/A-COM Model No. Part No. 408-4817 2034-5007-00 1051861-1 408-4817 2034-5008-00 1051942-1 www.amp.com/communications/com Specifications subject to change. 107 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Flexible Cable Right Angle Cable Plug, Solder 16.9 [.666] Ref. 13.5 [.530] Ref. 10.5 [.413] Ref. Ref. Plane 7.9 [.312] Hex. A 25.9 [1.020] Ref. Heat Shrink Tubing Cable Type RG/U Body Material & Finish Contact Captivation Contact Attachment Dimension A Yes Solder Yes Solder 16.0 .630 11.2 .440 55, 58, 141, 142, Stainless, Gold1 223, 303, 400 174, 188, 316 Stainless, Gold 1 Instruction Sheet M/A-COM Model No. Part No. 408-4816 2037-5005-02 1052063-1 408-4815 2037-5006-02 1052067-1 Coupling nut is passivated stainless steel. 1 Straight Cable Plug, Clamp 19.0 [.750] Ref. A 7.9 [.312] Hex Cable Type RG/U Body Material & Finish Contact Captivation Contact Attachment Dimension A Yes Solder Yes Solder 5.6 .220 2.9 .116 55, 58, 141, 142, Stainless, Pass. 223, 303, 400 174, 188, 316 Stainless, Pass. Straight Cable Jack, Clamp Instruction Sheet M/A-COM Model No. Part No. 408-4906 2001-7141-02 1050718-1 408-4906 2001-7188-02 1050721-1 17.8 [.700] Ref. A 7.9 [.312] Hex 108 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Cable Type RG/U Body Material & Finish Contact Captivation Contact Attachment Dimension A RG 55, 58, 141, 303 Stainless, Gold Yes Solder 174, 188, 316 Stainless, Pass. Yes Solder 5.6 .220 2.9 .116 Dimensions are in millimeters over [inches] Instruction Sheet M/A-COM Model No. Part No. 408-4906 2002-7141-00 1050900-1 408-4906 2002-7188-02 1050903-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Flexible Cable Bulkhead Feedthrough Cable Jack, Clamp 22.6 [.890] Max. 11.4 [.450] Ref. Plane 9.5 [.374] Ref. 6.0 [.235] Min. 7.9 [.312] Hex. .250-36, UNS-2A Cable Type RG/U 174, 188, 316 Ø 6.4 Min. [.250] 3.2 Max. [.125] Panel Body Material & Finish Stainless, Pass. Contact Captivation Yes Recommended Mounting Hole Contact Attachment Solder Instruction Sheet 408-4704 M/A-COM Model No. 2004-7188-02 Part No. 1050996-1 16.9 [.665] Ref. Right Angle Cable Plug, Clamp 12.9 [.509] Ref. 10.0 [.392] Ref. Ref. Plane 18.0 [.710] Max. 14.3 [.562] Max. 7.9 [.312] Hex. Cable Type RG/U RG 55, 58, 141, 300 174, 188, 316 Body Material & Finish Contact Captivation Contact Attachment Instruction Sheet M/A-COM Model No. Part No. Stainless, Gold Mechanical Solder 408-4965 2007-7141-00 1051136-1 Stainless, Pass. Mechanical Solder 408-4965 2007-7188-02 1051140-1 Straight Cable Plug, Crimp Ref. Plane 25.4 [1.00] Ref. 22.4 [.883] Ref. 7.9 [.312] Hex. Cable Type RG/U 174, 179, 187, 188, 316 RD316 58, 141, 303 55, 142, 223, 400 174, 179, 187, 188, 316 Body Material & Finish Contact Captivation Contact Attachment Crimp Tooling Part No. Instruction Sheet M/A-COM Model No. Part No. Stainless, Pass. Mechanical Solder/Crimp2 1055236-1 408-4661 2831-7388-02 1056443-1 Stainless, Pass. Stainless, Pass. Stainless, Pass. Brass, White Bronze Mechanical Solder/Crimp2 1055236-11 408-4661 2831-7316-02 1056436-1 Mechanical Solder/Crimp2 1055236-1 408-4661 2831-7358-02 1056441-1 Mechanical Solder/Crimp2 1055236-1 408-4661 2831-7341-02 1056438-1 Mechanical Solder/Crimp2 1055236-1 408-4661 2231-7388-36 1082034-1 Use die 1055270-1 to crimp RD316 ferrule. Use die 1055880-1 to crimp center contact. 1 2 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 109 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Flexible Cable Straight Cable Jack, Crimp 33.1 Ref. [1.304] 21.3 [.837] Ref. 19.3 [.761] Ref. Ref. Plane 6.35 Hex. [.250] 27.43 Max. [1.080] .250-36 UNS-2A 6.4 Hex. [.250] 7.9 Hex. [.312] Style A Heat Shrink Tubing Style B Cable Type RG/U Body Material & Finish Contact Captivation Contact Attachment 58 142 174, 316 55, 142, 223, 400 58, 141, 303 174, 188, 316 178, 196 Brass, Nickel Brass, Nickel Brass, Nickel Mechanical Mechanical Mechanical Solder Solder Solder Stainless, Pass. Mechanical Stainless, Pass. Mechanical Stainless, Pass. Mechanical Stainless, Pass. Mechanical Crimp Tooling Part No. Instruction Style Sheet M/A-COM Model No. — — — Part No. 408-4032 408-4032 408-4032 A A A Solder 1055236-1 408-4703 B 2032-5007-02 1051862-1 Solder Solder Solder 1055236-1 408-4704 1055236-1 408-4708 1055236-1 408-4806 B B B 2032-5021-02 1051867-1 2032-5003-02 1051855-1 2032-5026-02 1051869-1 1 1 1 447648-1 447648-2 447648-3 Refer to Tyco Customer Print for tooling requirement. Daniel’s/Mil Tooling used for contact and ferrule crimp. 1 Bulkhead Feedthrough Cable Jack, Crimp 26.4 Ref. [1.040] 6.4 Dia. [.250] Min. 11.4 [.450] .250-36 UNS-2A 6.0 Min. [.235] 3.2 Max. [.125] Panel Lock Washer 7.9 [.312] Hex Recommended Mounting Hole Cable Type RG/U 174, 179, 187, 188, 316 RD316 58, 141, 303 55, 142, 223, 400 142 174, 188, 316 Body Material & Finish Contact Captivation Contact Attachment Crimp Tooling Part No. Stainless, Pass. Mechanical Solder/Crimp2 1055236-1 Instruction Sheet M/A-COM Model No. Part No. 408-4661 2834-7388-02 1056452-1 Stainless, Pass. Mechanical Solder/Crimp2 1055236-13 408-4661 2834-7316-02 1056445-1 Stainless, Pass. Mechanical Solder/Crimp2 1055236-1 408-4661 2834-7358-02 1056450-1 Stainless, Pass. Mechanical Solder/Crimp2 1055236-1 Brass, Nickel Brass, Nickel Mechanical Mechanical Crimp Crimp 1 1 408-4661 2834-7341-02 1056447-1 408-4032 408-4032 — — 448103-1 448103-2 Refer to Tyco Customer Print for tooling requirement. Daniel’s/Mil Tooling used for contact and ferrule crimp. Use die 1055880-1 to crimp center contact. 3 Use die 1055270-1 to crimp RD316 ferrule. 1 2 110 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Flexible Cable 16.9 [.665] Ref. Right Angle Cable Plug, Crimp 13.5 [530] Ref. Ref. Plane 10.5 [.413] Ref. 20.4 [.802] Ref. 7.9 [.312] Hex. 17.2 [.677] Ref. Cable Type RG/U 174, 179, 187, 188, 316 58, 141, 303 174, 188, 316 178, 196 Body Material & Finish Contact Captivation Contact Attachment Crimp Tooling Part No. Instruction Sheet M/A-COM Model No. Part No. Stainless, Pass. Mechanical Solder 1055236-1 408-4659 2837-7388-02 1056462-1 Stainless, Pass. Mechanical Stainless, Pass. Mechanical Stainless, Pass. Mechanical Solder Solder Solder 1055236-1 408-4659 2837-7316-02 1056456-1 1055236-1 408-4659 2837-7358-02 1056460-1 1055236-1 408-4659 2837-7341-02 1056458-1 Right Angle Cable Plug, Crimp 16.9 Ref. [.665] 13.4 Ref. [.530] 12.1 [.475] Ref. 7.9 Hex [.312] 27.0 Ref. [1.062] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Crimp Tooling Part No. Body Material & Finish Contact Captivation Contact Attachment 55, 142, 223, 400 58, 141, 303 174, 188, 316 178, 196 Stainless, Pass. Epoxy Solder 1055236-1 408-4681 2037-5007-02 1052072-1 Stainless, Pass. Stainless, Pass. Stainless, Pass. Epoxy Epoxy Epoxy Solder Solder Solder 1055236-1 408-4682 2037-5056-02 1052093-1 1055236-1 408-4683 2037-5008-02 1052076-1 1055236-1 408-4801 2037-5100-02 1052098-1 Dimensions are in millimeters over [inches] Instruction Sheet M/A-COM Model No. Cable Type RG/U www.amp.com/communications/com Part No. Specifications subject to change. 111 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Panel Mount, Solder Pot Terminal 4 Hole Flange Mount Plug Receptacle 12.7 Sq. [.500] 18.0 Ref. [.707] 12.9 Ref. [.507] 8.6 Typ. 6.4 Dia. [.340] [.250] Min. 1.7 [.065] 1.3 Dia. [.050] 7.9 Hex [.312] Body Material & Finish Stainless, Passivated 4 Hole Flange Mount Jack Receptacle Contact Captivation Epoxy 9.5 [.375] RF Leakage db min. N/A M/A-COM Model No. 2051-0000-02 Part No. 1052324-1 12.7 [.500] Sq. 1.7 [.065] 8.6 Typ. [.340] Ø 0.9 [.035] Ø 1.3 [.050] Ø 2.6 4 Plcs. [.102] 7.6 [.299] Ref. Plane 2 Hole Flange Mount Plug Receptacle Temperature Range -65 to 125° C 14.6 [.575] .250-36UNS-2A Body Material & Finish Stainless, Passivated 2.6 Dia. [.102] 4 Plcs. Contact Captivation Epoxy RF Leakage db min. -(60-fGHz) Temperature Range -65 to 125° C M/A-COM Model No. 2052-0000-02 Part No. 1052422-1 18.0 Ref. [.707] 12.9 Ref. [.507] 6.6 [.260] 1.7 [.065] 0.8 Min. [.031] Dia. 12.2 [.481] 15.9 [.625] 7.9 Hex [.312] Body Material & Finish Stainless, Passivated 112 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Contact Captivation Epoxy Dimensions are in millimeters over [inches] 1.3 [.050] 2.6 Dia. [.102] 2 Plcs. RF Leakage db min. -(60-fGHz) Temperature Range -65 to 125° C M/A-COM Model No. 2051-1350-02 www.amp.com/communications/com Part No. 1052343-1 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Panel Mount, Solder Pot Terminal (Continued) 2 Hole Flange Mount Jack Receptacle 14.6 [.575] 9.5 [.375] 1.7 [.065] 5.7 Typ. [.223] 0.8 Dia. [.031] Min. 15.9 12.2 [.625] [.481] 1.3 Dia. [.050] 2.6 Dia. [.102] 2 Plcs. Body Material & Finish Stainless, Passivated Contact Captivation Epoxy RF Leakage db min. -(60-fGHz) 2 Hole Flange Mount Jack Receptacle Temperature Range -65 to 125° C M/A-COM Model No. 2052-1350-02 14.6 [.575] 0.8 [.030] 9.5 [.375] 5.7 [.223] 7.6 [.299] Ref. Ref. Plane 1.7 [.065] Ø 0.8 [.031] Ø 1.3 [.050] .250-36 UNS-2A Body Material & Finish Stainless, Passivated Bulkhead Feedthrough Jack Receptacle Contact Captivation Epoxy RF Leakage db min. -(60-fGHz) 12.2 [.481] Ø 15.9 [.625] Ø 4.1 [.162] Ø 2.6 2 Plcs. [.102] Temperature Range -65 to 125° C M/A-COM Model No. 2052-1300-02 Part No. 1052534-1 16.97 ± 0.25 [.668 ± 0] 12.7 [.500] Ref. Plane .250-36, UNS-2A Body Material & Finish Stainless, Passivated 7.9 [.312] Hex. 9.5 [.374] Ref. Ø 1.3 [.050] Ø 0.9 [.035] Lock Washer 11.4 [.450] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 1052544-1 Contact Captivation Epoxy Dimensions are in millimeters over [inches] 1.57 ± 0.25 [.062 ± 0] Ø 6.4 [.250] Min. Ø 4.1 [.162] 6.0 [.235] Min. Recommended Mounting Hole 3.2 Max. Panel [.125] RF Leakage db min. -(60-fGHz) Temperature Range -65 to 125° C M/A-COM Model No. 2056-0000-02 www.amp.com/communications/com Part No. 1053073-1 Specifications subject to change. 113 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Panel Mount Bulkhead Feedthrough Jack Receptacle, Solder Pot Terminal 10.8 [.424] Ref. Ref. Plane 1.57 ± 0.25 [.062 ± 0] 7.9 [.312] Hex. .250-36 UNS-2A Typ. 2 Plcs. Ø 0.9 [.035] Ø 6.5 [.255] Min. Ø 4.1 [.162] Ø 1.3 [.050] 5.8 [.230] Recommended Mounting Hole 3.2 [.125] Max. Panel 7.1 [.280] 6.0 [.236] Min. 12.7 [.500] 17.0 [.668] Body Material & Finish Stainless, Passivated Bulkhead Feedthrough Jack Receptacle, Solder Pot Terminal Contact Captivation Epoxy RF Leakage db min. -(60-fGHz) Temperature Range -65 to 125° C Part No. 1053134-1 17.0 [.668] 6.0 Min. [.235] 6.4 Min. [.250] M/A-COM Model No. 2058-0000-02 12.7 [.500] 1.6 [.062] 1.3 Dia. [.050] Recommended Mounting Hole Body Material & Finish Stainless, Passivated 4 Hole Flange Mount Plug Receptacle, Straight Terminal Contact Captivation Epoxy RF Leakage db min. N/A 12.9 Ref. [.507] 7.9 Hex [.312] Body Material & Finish Stainless, Passivated Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Temperature Range -65 to 125° C M/A-COM Model No. 2056-5006-02 Part No. 1053092-1 25.3 Ref. [.995] Contact Captivation Epoxy Dimensions are in millimeters over [inches] 12.7 Sq. [.500] 8.4 [.330] 8.6 Typ. [.340] 1.7 [.065] 114 4.1 Dia. [.162] 7.9 Hex. [.312] 4.1 [.162] RF Leakage db min. -(60-fGHz) 1.3 Dia. [.050] 2.6 Dia. [.102] 4 Plcs. Temperature Range -65 to 125° C M/A-COM Model No. 2051-1201-02 www.amp.com/communications/com Part No. 1052339-1 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Panel Mount, Straight Terminal 4 Hole Flange Mount Jack Receptacle 27.43 ± 0.25 [1.080 ± 0] .250-36 UNS-2A 9.5 [.375] 12.7 [.500] Sq. 14.99 ± 0.25 [.590 ± 0] 1.7 [.065] 8.6 Typ. [.340] Ø 1.3 [.050] Ø 4.1 [.162] Ref. Plane Body Material & Finish Stainless, Passivated Stainless, Passivated Stainless, Gold 2 Hole Flange Mount Plug Receptacle Ø 2.6 4 Plcs. [.102] 7.6 Ref. [.299] Contact Captivation None Epoxy Epoxy RF Leakage db min. -(100-fGHz) -(60-fGHz) -(60-fGHz) Temperature Range -65 to 165° C -65 to 125° C -65 to 125° C M/A-COM Model No. 2052-1200-02 2052-1201-02 2052-1201-00 Part No. 1052518-1 1052523-1 1052522-1 25.3 Ref. [.995] 12.9 Ref. [.507] 8.4 [.330] 6.6 [.260] 1.7 [.065] 12.2 [.481] 7.9 Hex [.312] Body Material & Finish Stainless, Passivated Contact Captivation Epoxy 2 Hole Flange Mount Jack Receptacle 4.1 [.162] 15.9 [.625] 1.3 Dia. [.050] 2.6 Dia. [.102] 2 Plcs. RF Leakage db min. -(60-fGHz) Temperature Range -65 to 125° C M/A-COM Model No. 2051-1352-02 Part No. 1052349-1 27.43 ± 0.25 [1.080 ± 0] 9.5 [.375] 1.7 [.065] 14.99 ± 0.25 [.590 ± 0] 5.7 [.223] Ø 1.3 [.050] 12.2 [.481] .250-36 UNS-2A Ref. Plane Body Material & Finish Stainless, Passivated Stainless, Passivated Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Ø 15.9 [.625] Ø 4.1 [.162] Contact Captivation None Epoxy Dimensions are in millimeters over [inches] 7.6 Ref. [.299] RF Leakage db min. -(100-fGHz) -(60-fGHz) Ø 2.6 2 Plcs. [.102] Temperature Range -65 to 165° C -65 to 125° C M/A-COM Model No. 2052-1351-02 2052-1352-02 www.amp.com/communications/com Part No. 1052548-1 1052552-1 Specifications subject to change. 115 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Panel Mount, Straight Terminal Bulkhead Feedthrough Jack Receptacle 12.7 [.500] 4.1 [.160] 10.82 [.426] Ref. Ref. Plane 1.9 [.076] Ø 1.3 [.050] .250-36 UNS-2A 7.9 [.312] Hex. Body Material & Finish Stainless, Passivated 2 Hole Flange Mount Right Angle Jack Receptacle Contact Captivation Epoxy Lockwasher RF Leakage db min. -(60-fGHz) Temperature Range -65 to 125° C M/A-COM Model No. 2058-5029-02 11.1 ± 0.13 [.437 ± .001] 15.0 ± 0.25 [.590 ± .010] 11.6 [.458] 9.65 [.380 ± 0.25 ± .010] Contact Captivation Mechanical 12.83 ± 0.25 [.505 ± .010] 12.2 [.481] 1.3 [.050] 4.1 [.162] Body Material & Finish Stainless, Passivated RF Leakage db min. -(90-fGHz) 5.7 [.223] Ø 2.6 2 Plcs. [.102] Temperature Range -65 to 165° C M/A-COM Model No. 2054-1241-02 Part No. 1052986-1 17.91 ± 0.25 [.705 ± .010] 14.99 ± 0.25 [.590 ± .010] 1.7 [.065] Part No. 1053222-1 Ø 15.9 [.625] 7.9 ± 0.25 [.312 ± .010] 1.7 [.065] 4 Hole Flange Mount Right Angle Jack Receptacle Ø 4.1 [.162] Ø 2.6 4 Plcs. [.102] Ø 4.1 [.162] 12.7 [.500] Sq. 9.7 11.6 [.382] Ref. [.458] Ø 1.3 [.050] 8.6 Typ. [.340] .250-36 UNS-2A Ref. Plane Body Material & Finish Stainless, Passivated Stainless, Passivated 116 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Contact Captivation Mechanical Mechanical Dimensions are in millimeters over [inches] RF Leakage db min. -(90-fGHz) -(90-fGHz) Temperature Range -65 to 165° C -65 to 165° C M/A-COM Model No. 2054-1201-02 2054-1231-02 www.amp.com/communications/com Part No. 1052978-1 1052982-1 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Panel Mount 4 Hole Flange Mount Jack Receptacle, Straight Terminal 9.5 [.375] 1.7 [.065] 12.7 [.500] Sq. 1.3 [.050] 8.6 [.340] Typ. Slot Width Ø 1.3 [.050] .250-36 UNS-2A Body Material & Finish Contact Captivation Stainless, Passivated Stainless, Passivated Epoxy Epoxy Ø 2.6 4 Plcs. [.102] 7.6 [.299] Ref. Ref. Plane Slot Width +.076/-.025 [+.003/-.001] 0.3 [.012] 0.5 [.018] 4 Hole Flange Mount Plug Receptacle, Slot Terminal RF Leakage db min. Temperature Range M/A-COM Model No. Part No. -(60-fGHz) -(60-fGHz) -65 to 125° C -65 to 125° C 2052-1610-02 2052-1612-02 1052561-1 1052563-1 12.7 [.500] 1.3 [.050] 12.9 [.507] 8.6 [.340] Typ. 1.7 [.065] 1.3 [.050] Dia. 2.6 Dia. [.102] 4 Plcs. Body Material & Finish Contact Captivation Stainless, Passivated Epoxy 4 Hole Flange Mount Plug Receptacle, Tab Terminal Slot Width +.076/-.025 [+.003/-.001] 0.5 [.018] RF Leakage db min. Temperature Range M/A-COM Model No. Part No. -(60-fGHz) -65 to 125° C 2051-1612-02 1052356-1 8.6 [.340] Typ. 9.9 Ref. [.390] 0.1 [.005] Thk. X 1.2 Wide [.050] Tab Ø 2.6 4 Plcs. [.102] 1.7 [.065] 12.9 Ref. [.507] Body Material & Finish Stainless, Passivated 12.7 Sq. [.500] 2.5 [.100] Contact Captivation Epoxy Tab Width 1.3 [.050] 9.5 [.375] 4 Hole Flange Mount Jack Receptacle, Tab Terminal 2.5 [.100] Temperature Range -65 to 125° C 12.7 Sq. [.500] 1.7 [.065] 0.13 [.005] Thk. X 0.5 Wide [.020] Tab 7.6 Ref. [.299] Body Material & Finish Stainless, Passivated Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 RF Leakage db min. -(60-fGHz) Contact Captivation Epoxy Dimensions are in millimeters over [inches] Tab Width .51 [.020] RF Leakage db min. -(60-fGHz) M/A-COM Model No. 2051-1618-02 Part No. 1052360-1 8.6 2 Plcs. [.340] Ø 2.6 4 Plcs. [.102] Temperature Range -65 to 125° C M/A-COM Model No. 2052-5636-02 www.amp.com/communications/com Part No. 1052898-1 Specifications subject to change. 117 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) 2 Hole Flange Mount Jack Receptacle, Panel Mount, Tab Terminal 9.5 [.375] 2.5 [.100] 5.7 [.223] 1.7 [.065] 0.13 [.005] Thk. X 1.27 Wide [.050] Tab 12.2 [.481] Ø 15.9 [.625] .250-36UNS-2A 7.59 [.299] Ref. Ref. Plane Body Material & Finish Stainless, Passivated 4 Hole Flange Mount Jack Receptacle, for Microstrip Transmission Line Circuits Contact Captivation Epoxy Horizontal Tab  Ø 2.6 [.102] 2 Plcs. RF Leakage db min. -(60-fGHz) Temperature Range -65 to 125° C 7.59 [.299] Ref. Ref. Plane Body Material & Finish Stainless, Passivated 12.7 [.500] Sq. 3.2 [.125] 8.6 [.340] Typ. 2.2 [.085] Contact Captivation Epoxy 2 Hole Flange Mount Jack Receptacle, for Microstrip Transmission Line Circuits 4.4 [.175] 0.3 [.010] .250-36 UNS-2A Ø 2.6 4 Plcs. [.102] RF Leakage db min. -(60-fGHz) 9.5 [.375] 1.7 [.065] Temperature Range -65 to 125° C 3.2 [.125] .250-36 UNS-2A Ref. Plane Body Material & Finish Stainless, Passivated Contact Captivation Epoxy Dimensions are in millimeters over [inches] M/A-COM Model No. 2052-1215-02 Part No. 1052528-1 5.7 [.223] 1.2 [.049] Ø 0.3 [.010] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 1052577-1 9.5 [.375] 1.7 [.065] 118 M/A-COM Model No. 2052-1658-02 12.2 [.481] Ø 15.9 [.625] Ø 2.2 [.085] 7.6 [.299] Ref. RF Leakage db min. -(60-fGHz) Ø 2.6 2 Plcs. [.102] Temperature Range -65 to 125° C M/A-COM Model No. 2052-5674-02 www.amp.com/communications/com Part No. 1052902-1 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Field Replaceable Hermetic Launchers 4 Hole Flange Mount Jack Receptacle with EMI/RFI Gasket EMI Gasket Accepts Pin Dia. A .250-36UNS-2A 12.7 Ref. [.500] 7.6 Ref. [.299] Ref. Plane 9.5 [.375] Captivation Stainless, Passivated Stainless, Passivated Stainless, Passivated Mechanical Mechanical Mechanical 4 Hole Flange Mount Jack Receptacle without EMI/RFI Gasket Ø 2.6 4 Plcs. [.102] 0.1 Ref. [.005] 1.7 [.065] Material & Finish 8.6 2 Plcs. [.340] Pin Diameter A .30 [.012] .38 [.015] .46 [.018] 9.5 [.375] M/A-COM Model No. 2052-3350-02 2052-3500-02 2052-3352-02 Part No. 1052622-1 1052684-1 1052625-1 12.7 Sq. [.500] 1.7 [.065] 8.6 2 Plcs. [.340] Accepts Pin Dia. A 7.6 Ref. [.299] Material & Finish Captivation Stainless, Passivated Stainless, Passivated Mechanical Mechanical Ø 2.6 4 Plcs. [.102] Pin Diameter A .51 [.020] .91 [.036] M/A-COM Model No. 2052-3362-02 2052-3358-02 Part No. 1052649-1 1052643-1 9.5 [.375] 2 Hole Flange Mount Jack Receptacle with EMI/RFI Gasket 1.7 [.065] 0.1 [.005] Min. EMI Gasket Accepts Pin Dia. A 5.6 [.222] 12.2 [.481] Ø 15.9 [.625] .250-36 UNS-2A Ref. Plane Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Material & Finish Captivation Stainless, Passivated Stainless, Passivated Stainless, Passivated Mechanical Mechanical Mechanical Dimensions are in millimeters over [inches] 7.6 Ref. [.299] Pin Diameter A .30 [.012] .38 [.015] .46 [.018] Ø 2.6 2 Plcs. [.102] M/A-COM Model No. 2052-3354-02 2052-3302-02 2052-3356-02 www.amp.com/communications/com Part No. 1052628-1 1052689-1 1052634-1 Specifications subject to change. 119 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) 2 Hole Flange Mount Jack Receptacle without EMI/RFI Gasket, Field Replaceable Hermetic Launchers 9.5 [.375] 5.7 [.223] 1.7 [.065] Ø 2.6 2 Plcs. [.102] 12.2 Ø 15.9 [.481] [.625] 7.6 [.299] PC Board Mount Vertical Jack Material & Finish Captivation Stainless, Passivated Stainless, Passivated Mechanical Mechanical 13.5 [.530] Ref. Plane 9.5 [.375] 7.6 [.299] Ref. Accepts Pin Dia A Pin Diameter A .51 [.020] .91 [.036] 3.9 Ref. [.155] M/A-COM Model No. 2052-3363-02 2052-3359-02 6.3 Sq. [.250] 5.1 2 Plcs. [.200] 5.1 Typ. [.200] Ø 1.3 [.050] 1.0 Sq. [.040] 4 Plcs. .250-36 UNS-2A Part No. 1052652-1 1052646-1 Ø 1.7 5 Plcs. [.067] Recommended Mounting Holes Style 1 6.35 ± 0.13 [.250 ± .005] 6.35 ± 0.13 [.250 ± .005] 9.53 ± 0.13 [.375 ± .005] 1.27 ± 0.03 [.050 ± .001] Style 2 19.94 [.785] 12.70 [.500] 5.28 [.203] 12.70 [.500] Ø 0.63 3 Plcs. [.025] Style 3 Material & Finish Stainless, Gold Brass, Gold Brass, Gold Brass, Gold Brass, Nickel Plate 120 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Style No. 1 1 2 2 3 M/A-COM Model No. 2062-0000-00 2262-0000-09 — — — Part No. 1053354-1 1223104-1 221789-1 221789-3 1274096-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) Right Angle Jack, PC Board Mount 13.5 [.530] 6.35 ± 0.25 [.250 ± 0] 3.9 Ref. [.155] 0.5 [.020] Typ. 11.6 [.458] 9.7 [.382] Ref. 6.4 Sq. [.250] Ø 1.3 [.050] 5.1 Typ. [.200] 2.8 [.110] Typ. 1.0 Sq. [.040] 4 Plcs. 5.1 2 Plcs. [.200] Ref. Plane 15.24 Max. [.600] 11.68 [.460] 1.93 ± .05 [.076 ± .002] 6.35 [.250] Ø 1.7 5 Plcs. [.067] Recommended Mounting Holes 9.65 Max. [.380] 4.60 Min. [.181] Dia. 1.02 ± .05 Typ. [.040 ± .002] 1.27 ± .03 Dia. [.050 ± .001] Material & Finish Stainless, Gold Brass, Gold Stainless, Gold In-Series Adapter, Jack to Jack Ref. Plane 3.94 [.155] M/A-COM Model No. 2064-0000-00 2264-0000-09 — 8.8 [.348] Ref. Part No. 1053378-1 1091559-1 221790-1 Ref. Plane 5.5 Across Flats [.218] 3.2 [.125] 12.7 [.500] Frequency DC-18.0GHz Material & Finish Stainless, Gold In-Series Adapter, Plug to Plug Captivation Epoxy* M/A-COM Model No. 2080-0000-00 Part No. 1053488-1 22.2 Ref. [.875] 3.2 [.125] 7.9 Hex [.312] Frequency DC-18.0GHz Material & Finish Stainless, Passivated 5.5 Across Flats [.218] Captivation Epoxy* M/A-COM Model No. 2081-0000-02 Part No. 1053635-1 *All adapters listed above employ epoxy captivation. Mechanically captivated versions are also available. Please consult AMP. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 121 Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) In-Series Adapter, Jack to Plug, Right Angle 15.9 Ref. [.625] 7.9 [.312] Hex 12.7 [.500] 14.8 [.583] 11.6 [.458] Frequency DC-12.4GHz Material & Finish Stainless, Passivated M/A-COM Model No. 2088-0000-02 Captivation Mechanical In-Series Adapter, Jack to Jack, Right Angle Part No. 1055065-1 11.7 [.459] 9.7 [.383] Ref. 11.7 [.459] 9.7 [.383] Ref. Ref. Plane .250-36 UNS-2A Ref. Plane Frequency DC-12.4GHz Material & Finish Stainless, Passivated M/A-COM Model No. 2086-0000-02 Captivation Mechanical In-Series Adapter, Plug to Plug, Right Angle Part No. 1055018-1 14.0 Ref. [.550] 11.1 [.438] Ref. 11.1 [.438] 14.0 Ref. [.550] Ref. Ref. Plane 7.9 Hex. [.312] Ref. Plane Frequency DC-18.0GHz 122 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Material & Finish Stainless, Passivated Dimensions are in millimeters over [inches] Captivation Mechanical M/A-COM Model No. 2087-1230-02 www.amp.com/communications/com Part No. 1055047-1 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMA Connectors (Continued) In-Series Adapter, Jack to Plug, Connector Saver 18.3 Ref. [.720] Ref. Plane 7.9 Hex. [.312] Frequency DC-18.0GHz Material & Finish Stainless, Passivated In-Series Adapter, Jack to Jack, Bulkhead Feedthrough 13.3 Ref. [.524] Ref. Plane .250-36 UNS-2A 5.6 Across Flats [.219] Captivation Epoxy M/A-COM Model No. 2082-5133-02 Part No. 1054426-1 22.2 [.875] 14.6 [.575] 1.7 [.065] .250-36 UNS-2A 6.4 Max Panel [.250] Lock Washer 6.0 [.235] Min. .250-36 UNS-2A 7.9 Hex. [.312] Ref. Plane Frequency DC-18.0GHz 9.5 [.375] Hex. 18.4 Ref. [.723] Material & Finish Stainless, Passivated Ø 6.4 [.250] Min. Ref. Plane Captivation Epoxy* Recommended Mounting Hole M/A-COM Model No. 2084-0000-02 Part No. 1054869-1 *Mechanically captivated version available. Please consult AMP. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 123 Catalog 1307191 Revised 10-00 RF Coax Connectors Tooling Solder Assembly Kit Brass SMA Connectors Item Description Kit Part Number 1055420-1 (M/A-COM Model Number 2098-5066-54) Dielectric Insert Tool M/A-COM Model No. 2098-5221-10 2098-5215-02 2098-5214-02 2098-5217-54 2098-5206-54 2098-5208-54 2098-5207-54 2098-5209-02 2098-5210-02 2098-5213-02 2098-5218-02 2098-5216-54 2098-5516-02 2098-5212-02 2098-5211-02 Center Contact Holder Dielectric Recess Tool Fixture Sub-Assembly Inserts — 2.16 [.085] (2) Inserts — 3.58 [.141] (2) Locator Tool Inserts Retainer Ring Pliers Solder Gauge 0.25 [.010] Solder Gauge 0.38 [.015] Solder Gauge 0.46 [.018] Locator Tools Part No. 1055454-1 1055448-1 1055447-1 1055450-1 1055439-1 1055441-1 1055440-1 1055442-1 1055443-1 1055446-1 1055451-1 1055449-1 1055500-1 1055445-1 1055444-1 Dielectric Insert Tool Solder Gage Retainer Ring Pliers Dielectric Recess Tool Fixture Sub-Assembly Center Contact Holder Universal Compression Crimp Tool Kit Part Number 1055835-1 (Kit M/A-COM Model Number 2598-5200-54) AMP Universal Compression Crimp Tool offers the ability to rapidly produce cable assemblies using solderless compression crimp connectors with semi-rigid cables. This universal assembly tool kit will attach SMA, OSP, N and TNC series connectors to 3.58 [.141], 2.16 [.085] and 6.35 [.250] cable quickly and consistently with excellent mechanical and electrical results. Crimp Frame Anvil Cable Supports Description Crimp Frame Calibration Gauge 3.58 [.141] Cable Support 2.16 [.085] Cable Support SMA Plug Anvil SMA Jack Anvil Type N Plug Anvil Type N Jack Anvil TNC Plug Anvil TNC Jack Anvil OSP Plug Anvil OSP Jack Anvil The tool kit permits single hand assembly. Anvils and cable supports can be quickly changed. Crimp lengths can be adjusted from .025 [.001] to 25.4 [1.000] in increments of .025 [.001]. Sharp radius bends in cables are easily accommodated. The kit contains: Gauge M/A-COM Model No. 2598-5196-54 2598-5197-54 2598-5198-54 2598-5199-54 2598-5201-54 2598-5202-54 2598-5203-54 2598-5204-54 2598-5205-54 2598-5206-54 2598-5207-54 2598-5208-54 Part No. 1055831-1 1055832-1 1055833-1 1055834-1 1055836-1 1055837-1 1055838-1 1055839-1 1055840-1 1055841-1 1055842-1 1055843-1 All tools may be purchased separately. 124 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.0/2.3 (50 Ohm/75 Ohm) Miniature coaxial connectors series 1.0/2.3 (CECC 22230 and IEC169-29) coaxial connectors are devised to meet the requirements of compact electronic instrumentation. All plugs and jacks with Zo = 50 Ω are designed for a number of different 50 Ω and 75 Ω cables. Owing to the large demand, the Series 1.0/2.3 has also been optimized as a 75 Ω design into the GHz range. The different types of coupling mechanisms, such as screw on, slide-in and latching coupling permit space-saving installation. The Siemax Surface Mount Multi Coax Connectors combine the benefits of surface mount technology and modular design. This multi coax connector is packaged in tape-and-reel for automatic placement, has optimum solder joints and 100% reflow suitability. This connector is ideal for systems requiring superior packaging density because it can be placed on both sides of the printed circuit board. The modular design provides flexibility in terms of the number of poles offered (two-, three-, or four-poles). It can be stacked, enabling any required configuration to be produced. The Siemax Connector also allows the use of any other connector series, e.g. SMB, is resistant to high temperatures, and is robust, with reliably sustained coplanarity. In addition, an extensive range of measurement accessories, adapters as well as terminations is available. The quality-determining factors have been established on the basis of corresponding measurements and test procedures in accordance with national and international standards for RF connectors (DIN 47275, VG 95205, IEC 1169-1, MIL-C-39012 etc.). High-quality materials ensure high reliability even in industrial atmospheres. The contact principle is the pin-socket principle and the resilient contacts which are engineered in a noble metal plating/beryllium copper base on both the inner and outer contacts ensure perfect contact mating. The inner conducter parts are held in PTFE (Polytetrafluoroethylene). The reduced dimensions of all component parts of these connectors permit a compact hole spacing (installation pitch) of 6.8 [0.27] depending upon the corresponding cable diameters. The cable is connected by crimping the cable braid to the plug or jack body, the inner conductor is soldered or crimped. In most applications, the plug and jack belong to the same coupling type group. In special instances, such as for measurement purposes, different coupling types can be used together. Between Series Adapters For Series 1.0/2.3 Adapters please see pages 255-264. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 125 Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.0/2.3 (50 Ohm/75 Ohm) (Continued) Technical Data Type A Coupling Types Screw coupling; version with union nut Electrical and mechanical characteristics in accordance with CECC 22230 This type permits the plug and jack to be screwed together manually by means of a union nut secured to the plug. This is necessary for readily accessible locations, front panel test points and cable connections. Characteristic impedance — 50 Ω/75 Ω Frequency range — up to 10 GHz/2 GHz Reflection factor, referred to 50 Ω cable1 — up to 1 GHz, r ≤ 0.05 up to 4 GHz, r ≤ 0.07 up to 10 GHz, r ≤ 0.15 Reflection factor, referred to 75 Ω cable1 — up to 2 GHz, r ≤ 0.10 Insulation resistance — initial value ≥ 1 GΩ after stressing ≥ 200 MΩ Screening effectiveness2 — ≥ 90 dB Inner conductor contact resistance — after stressing ≤ 10 mΩ Outer conductor continuity — after stressing ≤ 7.5 mΩ Voltage proof3 — flexible cables (RG 316) — at sea level, 750 V, 50 Hz — at 20 km altitude, 150 V, 50 Hz Working voltage3 — flexible cables (RG 316) — at sea level, 350 V, 50 Hz — at 20 km altitude, 65 V, 50 Hz Service life — 500 cycles Climatic category — 40/85/21 Type C Slide-in coupling; version with centering ferrule In this type of coupling, the plug features a guide ferrule with a conical entry surface. This ensures that the floatable bulkhead plugs with cable connection make a reliable electrical connection to the rigid installed jack. Examples of this are single and multi-contact connections of slide-in applications. “W” denotes the allowed spacing of the mounting panel for satisfactory contact when the connection is made. 1 Guide values, depending on cable type and connector style. 2 Values apply to a straight screw and latching coupling with suitable cable. 3 Some cables suitable for use with these connectors have lower characteristic values than specified here. Type F Latching coupling (Quick Lock) In this version, the cable plugs bear a funnel ferrule with built-in spring which snaps into a groove on the jack, simultaneously locking the connection. The connec- 126 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] tion can be easily separated by lightly pulling the outer sleeve of the plug. This type of coupling provides the same amount of axial tensile strength as the screw coupling, but can be used with a higher packing density. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.0/2.3, 50 Ohm Plugs, Solder/Crimp Ø 6.5 [0.26] 18.0 [0.71] Cable Coupling Type RG 316 A Ø Max. 2.67 0.105 1393670-1 Part No. Ø Max. 2.6 0.10 2-1393670-6 Ø Max. 2.6 0.10 4-1393670-4 Ø Max. 2.6 0.10 3-1393670-2 1) 1) Detent for jack Right Angle Plug, Solder/Crimp 22.5 [0.89] 4.1 [0.16] Ø 7.9 [0.31] 15.7 [0.62] Cable Coupling Type RG 316 F Part No. Ø 6.5 [0.26] Bulkhead Jack, Solder/Crimp Ø 4.1 [0.16] 0.6 1.5 [0.02]...[0.06] Mounting Panel Right Angle Bulkhead Jack, Solder/Crimp Ø 6.6 [0.26] 13.5 [0.53] 12.0 [0.47] A, F Cable Coupling Type RG 316 A, F Part No. Ø 4.1 [0.16] 12.7 [0.5] Bulkhead Solder Jack Coupling Type ECN0857-P 16.8 [0.66] 13.4 [0.53] 3.6 [0.14] Cable RG 316 Part No. Ø 7.3 [0.29] Ø 7.3 [0.29] Ø 4.1 [0.16] Coupling Type C, F Part No. 1393670-8 0.6 1.5 [0.02]...[0.06] Mounting Panel 8.0 [0.31] Vertical PC Board Mount Jack 5.08 Ø 0.9 [0.2] [0.04] 8.4 [0.33] 6.0 [0.24] ECN0867-W Ø 4.1 [0.16] Coupling Type 0.95 [0.04] 0.5 [0.02] 11.1 [0.44] a C, F Pitch 2.54 [0.10] C, F Ø 1.5 [0.06] Dim a 14.6 0.57 15.6 0.61 Part No. 3-1393670-4 3-1393670-5 Recommended Mounting Holes Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 127 Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.0/2.3, 50 Ohm (Continued) Vertical PC Board Mount Bulkhead Jack 19.5 [0.77] 16.0 [0.63] 0.5 [0.02] 0.95 [0.04] 5.08 [0.2] Ø 0.9 [0.04] Coupling Type A, C, F M5.5x0.5 [0.22]x[0.02] Pitch 6.0 [0.24] 12.0 [0.47] Part No. 3-1393670-6 2.54 [0.10] Ø 1.5 [0.06] Recommended Mounting Holes Right Angle PC Board Mount Bulkhead Jack 15.9 [0.63] Coupling Type A, C, F 5.9 [0.23] 7.0 [0.28] Part No. 3-1393670-9 7.4 [0.29] Ø 4.1 [0.16] Ø 0.55 [0.02] 0.55 [0.02] 3.7 3.3 [0.15] [0.13] 3.6 [0.14] 7.3 [0.29] M5.5x0.5 [0.22]x[0.02] Inner Conductor Pitch Ø 1.0 [0.04] ECN0870-G 2.54 [0.10] Recommended Mounting Holes Series 1.0/2.3, 75 Ohm Plugs, Solder/Crimp Ø 6.5 [0.26] 18.0 [0.71] Cable Coupling Type RG 179 A Ø Max. 2.6 0.10 Part No. 5-1393670-5 1) 1) Detent for jack Ø 7.9 [0.03] 26 [1.02] Right Angle Plug, Solder/Crimp 4.1 [0.16] 22.5 [0.89] Ø 6.5 [0.26] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Coupling Type RG 179 F ST 212 F 02Y(St)CY 0.45/2.0 2YCCY 0.4/2.0 2YC(mS)CY 0.4/2.5 F F F Ø Max. 2.67 0.105 3.2 0.13 3.6 0.14 4.8 0.19 5.0 0.20 Part No. 6-1393670-2 6-1393670-5 6-1393670-4 6-1393670-0 Ø 7.9 [0.31] 15.7 [0.62] 128 Cable Dimensions are in millimeters over [inches] Cable Coupling Type RG 179 F 02Y(St)CY 0.45/2.0 F Ø Max. 2.67 0.105 3.6 0.14 www.amp.com/communications/com Part No. 2-1393670-6 7-1393670-0 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.0/2.3, 75 Ohm (Continued) Bulkhead Jack, Solder/Crimp Ø 4.1 [0.16] 0.6 1.5 [0.02]...[0.06] Mounting Panel Right Angle Bulkhead Jack, Solder/Crimp Ø 6.6 [0.26] 13.5 [0.53] 12.0 [0.47] 16.8 [0.66] 13.4 [0.53] 3.6 [0.14] Cable Coupling Type RG 179 A Cable Coupling Type RG 179 A, F Ø Max. 2.67 0.105 Part No. 8-1393670-0 ECN0857-P Ø 4.1 [0.16] 12.7 [0.5] Ø Max. 2.67 0.105 Part No. 3-1393670-2 Ø 7.3 [0.29] Vertical PC Board Mount Bulkhead Jack 21.0 [0.83] 17.5 [0.69] 0.5 [0.02] 0.95 [0.04] 5.08 [0.2] Ø 0.9 [0.04] 6.0 [0.24] 12.0 [0.48] M5.5x0.5 [0.22]x[0.02] Pitch Ø 7.3 [0.29] 2.54 [0.10] Ø 1.5 [0.06] Recommended Mounting Holes Coupling Type A, C, F Part No. 8-1393670-3 Right Angle PC Board Mount Bulkhead Jack 6.9 [0.27] 15.9 [0.63] 6.5 [0.26] Ø 4.1 [0.16] 3.7 7.0 [0.15] [0.28] 3.2 [0.13] 0.9 [0.24] 3.5 [0.14] M5.5x0.5 [0.22]x[0.02] Ø 0.7 [0.03] 2.54 [0.10] Recommended Mounting Holes Coupling Type A, C, F Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Pitch Ø 1.5 [0.06] Dimensions are in millimeters over [inches] Part No. 4-1393670-0 www.amp.com/communications/com Specifications subject to change. 129 Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.0/2.3 (50 Ohm/75 Ohm) (Continued) Accessories 4.8 [0.19] 2.4 [0.09] 5.0 [0.20] Soldering aid (sleeve) for jack 1393670-8 with solder connection. Part No. 2-1393562-2 For cable size similar to RG 179 and RG 316 3.5 [0.14] 0.8 [0.03] 2.1 [0.08] Installation example: Tin-Soldered + 0.00 3.5 – 0.50 + .000 [0.14 – 0.02 ] + 0.00 5.5 – 0.50 + .000 0.00 8.5 +– 0.50 + .000 [0.33 – 0.02 ] [0.22 – 0.02 ] ECN0900-7 Sleeve Pushed onto Shielding Braid Ø 5.5 [0.22] ECN0901-F Cap for sealing and screening of jacks 9.0 [0.35] Part No. 1393562-4 11.0 [0.43] Ø 6.5 [0.26] Note: For more accessories, see page 141. 130 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) General The Series 1.6/5.6 mS connectors have been modified to incorporate improved technical advantages. Transmission values have been greatly improved while maintaining the proven positive characteristics of the previous generations. All types of this new “third generation” Series 1.6/5.6 mS connectors are connectioncompatible with their predecessor. Connectors are available in straight and angled versions as well as with different mechanisms for screw (type A), snap-on (type B), slide-in (type C), and latching (type F) coupling. All connectors of different coupling mechanisms are compatible with each other. Today’s PCM technology demands place the Series 1.6/5.6 mS connectors as a most suitable component for transmission of high bit rates. Plug Jack 9.7 [0.38] 9.2 [0.36] Ø 5.6 [0.22] 6.7 [0.26] Ø 2.5 [0.10] M9x0.5 [0.35]x[0.02] Ø 8.25 Ø 6.6 M9x0.5 [0.35]x[0.02] [0.32] [0.26] Ø 1.0 [0.03] 5.5 [0.22] 4.1 [0.16] 0.25 [0.01] 7.0 [0.28] 6.5 [0.26] The connectors are designed according to the pin-socket principle. The contacts are partially goldplated, ensuring long service life and stable contact resistance for a high number of intermateability cycles. Between Series Adapters For Series 1.6/5.6 Adapters please see Pages 255-264. The inner conductor parts are secured so that they cannot be displaced. The insulating parts are made of PEEK (polyetheretherketone) or PC (polycarbonate). Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] ECN0934-R The cable inner conductors are soldered on, while the outer conductors are screwed or crimped on. Also, cable clamp which is independent of the braid clamping secures the connection point against tensile stressing for both methods of connection. In addition, assemblyfriendly connectors with full crimp and IDC (Insulation Displacement Contact) connection are included within the scope of delivery. The connectors are characterized by high mechanical strength and low space requirement. Connection possibilities exist for a number of different cables, including highlyflexible cable types (with foam insulation) with low attenuation or small diameter. Terminations and adapters (see also measurement accessories) round out the spectrum. www.amp.com/communications/com Specifications subject to change. 131 Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) (Continued) Technical data Type A Coupling Types Screw coupling; version with union nut Electrical and mechanical characteristics in accordance with CECC 22240 This type permits the plug and jack to be screwed together manually by means of a union nut secured to the plug manually, thus preventing the coupling from being pulled apart. This is necessary for readily accessible locations, front panel test points and cable connections. Characteristic impedance — 75 Ω Frequency range — up to 8 GHz Reflection factor1, referred to — flexible cables, straight types — up to 1 GHz, r ≤ 0.02 up to 4 GHz, r ≤ 0.06 up to 8 GHz, r ≤ 0.10 flexible cables, angled types — up to 1 GHz, r ≤ 0.04 up to 2 GHz, r ≤ 0.06 up to 4 GHz, r ≤ 0.10 Insulation resistance — initial value, ≥ 10 GΩ after stressing, ≥ 1 GΩ Screening effectiveness — (straight screw connector at 1 GHz) ≥ 100 dB Inner conductor contact resistance — after stressing ≤ 8 mΩ Outer conductor continuity — after stressing ≤ 4 mΩ Voltage proof2 — flexible cables (RG 59) — at sea level, 1.5 kV, 50 Hz at 20 km altitude, 300 V, 50 Hz Working voltage2 — flexible cables (RG 59) — at sea level, 500 V, 50 Hz at 20 km altitude, 125 V, 50 Hz Service life — 500 cycles Climatic category — 40/85/21 Type B Snap-on coupling (push-pull) Connectors of this type offer fast make/break. They can be used for test and maintenance applications and also if there is lack of space and connectors with screw coupling cannot be used. Type C Slide-in coupling; version with centering ferrule In this type of coupling, the plug features a guide ferrule with a conical entry surface. This ensures that the floatable bulkhead plugs with cable connection make a reliable electrical connection to the rigid installed jack. Examples of this are single and multi-contact connections of slide-in applications. “W” denotes the allowed spacing of the mounting panel for satisfactory contact when the connection is made. Guideline values, depending on cable type and connector style. 2 Some cable types suitable for use with these connectors have lower characteristic values than specified here. 1 Type F Latching coupling (Quick Lock) In this version, the cable plugs bear a funnel ferrule with built-in spring which snaps into a groove on the jack, simultaneously locking the connection. The connec- 132 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] tion can be easily separated by lightly pulling the outer sleeve of the plug. This type of coupling provides the same amount of axial tensile strength as the screw coupling, but can be used with a higher packing density. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) (Continued) Plugs, Solder/Clamp 37.0 [1.46] Ø 10.8 [0.43] Ø 10.8 [0.43] Cable 2YCCY 0.7/4.4 Coupling Type Ø Max. 7.8 0.31 A Part No. 1393682-1 ECN0948-W 37.0 [1.46] Ø 10.8 [0.43] Ø 12.8 [0.50] Cable 2YCCY 1.0/6.5 2YC(mS)CY 1.0/6.5 Cable a Ø 10.8 [0.43] Ø 10.8 [0.43] Coupling Type A Coupling Type 2YCY 0.4/2.5 A 2YCCY 0.4/2.5 A 2YC(mS)CY 0.4/2.5 A 2YCY 0.7/4.4 A RG 59 A 2YC(mS)CY 0.5/3.0 A Dim. a 30.7 1.21 30.7 1.21 30.7 1.21 32.9 1.30 32.9 1.30 32.9 1.30 Ø Max. 9.8 0.31 Part No. 1393682-2 Ø Max. Part No. 4.1 0.16 4.8 0.19 5.0 0.20 6.1 0.24 6.25 0.25 6.2 0.24 1-1393682-1 1-1393682-2 1-1393682-3 30.2 [1.19] Ø 11.5 [0.45] Ø 10.8 [0.43] Cable Coupling Type 02Y(St)CY 0.45/2.0 F Ø Max. 3.6 0.14 Part No. 1393681-8 Plugs, Solder/Crimp Cable Coupling Type RG 179 A 2YCCY 0.4/2.5 A 2YC(mS)CY 0.4/2.5 A 2YC(mS)CY 0.5/3.0 A 2YCY 0.7/4.4 A 02Y(St)CY 0.45/2.0 A a Ø 10.8 [0.43] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Ø 10.8 [0.43] Dimensions are in millimeters over [inches] Dim. a 32.5 1.28 32.5 1.28 35.5 1.40 35.5 1.40 35.5 1.40 32.5 1.28 www.amp.com/communications/com Ø Max. Part No. 2.6 0.105 4.8 0.19 5.0 0.20 6.2 0.24 6.1 0.24 3.6 0.14 1393680-2 1393680-3 1393680-4 1393680-5 1393680-9 Specifications subject to change. 133 Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) Plugs, Solder/Crimp (Continued) 32.0 [1.26] Version with Preassembled Insulation Ø 10.8 [0.43] Ø 11.5 [0.45] Cable Coupling Type 02Y(St)CY 0.45/2.0 F Ø Max. 3.6 0.14 1393672-3 Part No. Ø Max. 3.6 0.14 1393672-9 32.0 [1.26] Preassembled Isolation Parts Ø 10.8 [0.43] Ø 11.5 [0.45] Right Angle Plugs, Solder/Crimp 24.7 [0.97] Cable Coupling Type 02Y(St)CY 0.45/2.0 F Cable Ø 10.8 [0.43] a Ø 10.8 [0.43] Coupling Type 2YCCY 0.4/2.5 A 2YC(mS)CY 0.4/2.5 A 2YCY 0.7/4.4 A RG 59 A 2YC(mS)CY 0.5/3.0 A Dim. a 13.0 0.51 13.0 0.51 15.8 0.62 15.8 0.62 15.8 0.62 Ø Max. 4.8 0.19 5.0 0.20 6.1 0.24 6.25 0.25 6.2 0.24 Part No. Part No. 2-1393682-0 2-1393682-2 24.7 [0.97] Ø 10.8 [0.43] Cable Coupling Type RG 179 A Cable Coupling Type 02Y(St)CY 0.45/2.0 F Ø Max. 2.67 0.105 Part No. 2-1393682-3 18.2 [0.72] Ø 10.8 [0.43] 24.2 [0.95] Ø 11.5 [0.45] Ø Max. 3.6 0.14 Part No. 1-1393681-0 13.0 [0.51] Ø 10.8 [0.43] 134 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) (Continued) Right Angle Plugs, Solder/Crimp 24.7 [0.97] Ø 10.8 [0.43] a Cable Coupling Type 2YCCY 0.4/2.5 A 2YC(mS)CY 0.4/2.5 A 02Y12YC(mS)C6Y 0.45/2.0 A 02Y(St)CY 0.45/2.0 A Dim. a 15.0 0.59 15.0 0.59 15.0 0.59 15.0 0.59 Ø Max. 4.8 0.19 5.0 0.20 4.0 0.16 3.6 0.14 Part No. 1-1393680-3 1-1393680-6 1-1393680-8 Right Angle Plugs, IDC Connection 24.7 [0.97] Ø 10.8 [0.43] Cable Coupling Type 02Y(St)CY 0.45/2.0 A 2YCY 0.4/2.0 A Cable Coupling Type 02Y(St)CY 0.45/2.0 F Ø Max. 3.6 0.14 4.1 0.16 Part No. 1393757-9 1393757-8 17.5 [0.69] ECN1615-7 IDC Connection Right Angle Plug, Solder/Crimp 25.0 [0.98] Ø 11.5 [0.45] Ø Max. 3.6 0.14 Part No. 1393672-5 15.0 [0.59] ECN0976-2 Crimp Connection Bulkhead Jacks, Solder/Clamp a 2.0 Max. [0.08] Mounting Panel 14.3 [0.56] Max. M9.0x0.5 [0.35]x[0.02] Ø 10.8 [0.43] Ø 10.8 [0.43] Ø 8.2 [0.32] Cable Coupling Type 2YCY 0.4/2.5 A, B, F 2YCCY 0.4/2.5 A, B, F 2YC(mS)CY 0.4/2.5 A, B, F 2YCY 0.7/4.4 A, B, F RG 59 A, B, F 2YC(mS)CY 0.5/3.0 A, B, F ECN0943-Q Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Dim. a 28.1 1.11 28.1 1.11 28.1 1.11 30.4 1.20 30.4 1.20 30.4 1.20 www.amp.com/communications/com Ø Max. Part No. 4.1 0.16 4.8 0.19 5.0 0.20 6.1 0.24 6.25 0.25 6.2 0.24 3-1393682-2 3-1393682-3 3-1393682-5 Specifications subject to change. 135 Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) (Continued) Bulkhead Jacks, Solder/Clamp (Continued) 34.5 [1.36] 2.0 Max. [0.08] Mounting Panel 14.3 [0.56] Max. M9.0x0.5 [0.35]x[0.02] Ø 10.8 [0.43] Ø 12.8 [0.50] Ø 8.2 [0.32] 32.5 [1.28] 10.6 [0.42] 2.5 Max. [0.10] Mounting Panel Cable Coupling Type 2YCCY 1.0/6.5 A, B, F 2YC(mS)CY 1.0/6.5 A, B, F Cable Coupling Type RG 179 B, C, F Ø Max. 9.8 0.38 9.8 0.38 Part No. 1393682-4 ECN0944-Y M9.0x0.5 [0.35]x[0.02] Ø 10.8 [0.43] Ø 10.8 [0.43] Ø Max. 2.67 0.105 Part No. 4-1393682-2 Ø 8.2 [0.32] Bulkhead Jacks, Solder a 19.4 [0.76] 6.5 [0.26] 12.0 [0.47] Mounting Panel 3.0 [0.12] Max. 3.0 [0.12] Max. M9.0x0.5 [0.35]x[0.02] Ø 8.2 [0.32] 19.4 [0.76] 12.0 [0.47] M9.0x0.5 [0.35]x[0.02] Mounting Panel Ø 10.8 [0.43] Ø 8.2 [0.32] Ø 10.8 [0.43] 8.0 [0.31] 1.7 [0.07] ECN0982-B Dim. a 22.3* 0.88 23.5 0.93 Ø Max. Part No. A, B, C, F 1-1393681-1 A, B, C, F 1-1393681-9 Ø 0.6 [0.02] Coupling Type A, B, C, F ECN0984-S Part No. 1-1393681-3 *Without soldering tags on outer conductor, dimension a up to inner conductor end. Bulkhead Jacks, Solder/Crimp 29.8 [1.17] 2.0 Max. [0.08] Mounting Panel 14.3 [0.56] Max. M9.0x0.5 [0.35]x[0.02] Ø 10.8 [0.43] Ø 10.8 [0.43] Cable Coupling Type RG 179 A, B, F 02Y12YC(mS)C6Y 0.45/2.0 A, B, F 06YCC(St)6Y 0.4/1.6 A, B, F 02Y(St)CY 0.45/2.0 Ø 8.2 [0.32] A, B, F Ø Max. 2.67 0.105 4.0 0.16 3.3 0.13 3.6 0.14 Part No. 2-1393680-2 2-1393680-4 2-1393680-5 0-1393672-6 ECN0947-N 29.8 [1.17] 2.0 Max. [0.08] Mounting Panel M9.0x0.5 [0.35]x[0.02] Ø 10.8 [0.43] Ø 10.8 [0.43] Crimp Connection 136 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 With preassembled insulation parts Cable Coupling Type 02Y(St)CY 0.45/2.0 A, B, F Ø Max. 3.6 0.14 Part No. 0-1-1393672-4 Ø 8.2 [0.32] Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) (Continued) Right Angle Bulkhead Jack, Solder/Clamp 28.4 [1.12] 13.8 [0.54] 2.0 [0.08] Max. Mounting Panel M9.0x0.5 [0.35]x[0.02] Ø 8.2 [0.32] Ø 10.8 [0.43] Cable Coupling Type 2YCCY 1.0/6.5 A, B, F 2YC(mS)CY 1.0/6.5 A, B, F Ø Max. 9.8 0.39 9.8 0.39 Part No. 1393682-8 21.0 [0.83] ECN0966-U Ø 12.8 [0.50] 27.2 [1.07] Cable 12.6 [0.50] 2.0 [0.08] Max. Mounting Panel M9.0x0.5 [0.35]x[0.02] Ø 8.2 [0.32] Ø 10.8 [0.43] a Coupling Type 02Y(St)CY 0.45/2.0 A, B, F 2YCCY 0.4/2.5 A, B, F 2YC(mS)CY 0.4/2.5 A, B, F 2YCY 0.7/4.4 A, B, F RG 59 A, B, F 2YC(mS)CY 0.5/3.0 A, B, F Cable Coupling Type Dim. a 13.0 0.51 13.0 0.51 13.0 0.51 15.8 0.62 15.8 0.62 15.8 0.62 Ø Max. Part No. 3.6 0.14 4.8 0.19 5.0 0.20 6.1 0.24 6.25 0.25 6.2 0.24 4-1393682-9 Dim. a 15.0 0.59 15.0 0.59 15.0 0.59 15.0 0.59 15.0 0.59 15.0 0.59 Ø Max. Part No. 2.67 0.105 4.8 0.19 5.0 0.20 4.0 0.16 3.3 0.13 3.6 0.14 3-1393680-0 4-1393682-6 4-1393682-8 ECN0967-3 Ø 10.8 [0.43] Right Angle Bulkhead Jack, Solder/Crimp 27.2 [1.07] 12.6 [0.50] 2.0 [0.08] Max. Mounting Panel M9.0x0.5 [0.35]x[0.02] Ø 8.2 [0.32] Ø 10.8 [0.43] a RG 179 A, B, F 2YCCY 0.4/2.5 A, B, F 2YC(mS)CY 0.4/2.5 A, B, F 02Y12YC(mS)C6Y 0.45/2.0 06YCC(St)6Y 0.4/1.6 A, B, F 02Y(St)CY 0.45/2.0 A, B, F A, B, F 3-1393680-2 3-1393680-5 4-1393682-3 3-1393680-7 ECN0969-J Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 137 Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) (Continued) Right Angle Bulkhead Jack, IDC Connection 27.2 [1.07] 12.6 [0.50] 2.0 [0.08] Max. Mounting Panel M9.0x0.5 [0.35]x[0.02] Ø 8.2 [0.32] Ø 10.8 [0.43] 17.5 [0.69] ECN1614-Y Vertical PC Board Mount Jack Cable Coupling Type 02Y(St)CY 0.45/2.0 A, B, F Ø Max. 3.6 0.14 29.2 [1.15] 4.2 [0.17] 1.0 [0.04] 1-1393757-6 Coupling Type A, B, F 14.4 [0.57] Ø 0.8 [0.03] Part No. Part No. 1-1393681-6 M9.0x0.5 [0.35]x[0.02] Recommended Mounting Holes View A Ø 9.0 [0.35] Ø 8.2 [0.32] 0.8 [0.03] 5.08 [0.20] ECN0986-9 5.08 [0.20] 10.8 [0.43] 10.0 [0.39] b a c Ø 8.2 [0.32] 10.8 [0.43] 5.08 [0.20] 5.08 [0.20] M9.0x0.5 [0.35]x[0.02] Ø 1.3 [0.05] Pitch 2.54 [0.10] Inner- and outer conductor, press-fit Coupling Type A, B, F Dim. a 6.0 0.24 Dim. b 27.2 1.07 Dim. c 16.4 0.65 Part No. 2-1393757-0 10.0 [0.39] Recommended Mounting Holes Pitch 2.54 [0.10] Thickness 1.5 Max. [0.06] 0.09 Ø 1.0 +– 0.06 + 0.004 5 Plcs. [0.04 – 0.002 ] 138 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) (Continued) Right Angle PC Board Mount Bulkhead Jack Ø 8.2 [0.32] b Coupling Type A, B, F d A, B, F M9.0x0.5 [0.35]x[0.02] c a 4.5 [0.18] A, B, F Dim. a 4.0 0.16 3.3 0.13 3.7 0.15 Dim. b 16.0 0.63 16.0 0.63 22.9 0.90 Dim. c 6.0 0.24 6.0 0.24 6.45 0.25 Dim. d 10.75 0.42 10.75 0.42 11.25 0.44 Dim. Part No. e 1.3 0.05 2-1393681-1 1.3 0.05 2-1393681-2 1.8 0.07 2-1393681-3* *With positioning and snap-on system onto PC board Recommended Mounting Holes Øe 4 Plcs. Ø 1.3 [0.05] Pitch 2.54 [0.10] U-link Plug/Plug b a Coupling Type A 24.4 [0.96] A Dim. a ± 0.1 [0.004] 15.0 0.59 30.0 1.18 Dim. b Max. 26.5 1.04 41.5 1.63 Dim. a ± 0.1 [0.004] 15.0 0.59 30.0 1.18 Dim. b Max. 26.5 1.04 41.5 1.63 Part No. 1393681-1 1393681-2 Ø 10.8 [0.43] b a Coupling Type 22.3 [0.88] B B Part No. 1393681-3 1393681-4 Ø 10.8 [0.43] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 139 Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) (Continued) 37.1 [1.46] Ø 25.0 ± 0.05 [0.98 ± 0.002] U-link Jack/Jack/Jack Coupling Type A, B, F Part No. 2-1393681-5 Coupling Type A, B, F Part No. 1393679-1 43.1 [1.70] 9.5 [0.37] * 14.6 [0.57] Ø 8.2 [0.32] M9.0x0.5 [0.35]x[0.02] Ø 10.8 [0.43] U-link Plug/Plug/Jack Ø 10.8 [0.43] 15.0 [0.59] 24.5 [0.96] 41.2 [1.62] * M9.0x0.5 [0.35]x[0.02] *Filtered mating face 140 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series 1.6/5.6 mS (75 Ohm) (Continued) Accessories M9.0x0.5 [0.35]x[0.02] These components are provided when bulkhead jack part numbers are ordered, but can also be ordered separately. Threaded ring for installation of bulkhead jacks Part No. 1-1393562-0 Ø 10.8 [0.43] 2.3 [0.09] Ø 9.1 [0.36] Isolation washer Ø 14.0 [0.55] Part No. 1393562-5 Ø 10.7 1.0 [0.04] 1.8 [0.42] [0.07] Isolation washer Ø 14.0 [0.55] Part No. 1393562-6 Ø 9.1 [0.36] 1.0 [0.04] Ø 9.6 [0.38] Cap for sealing and screening of jacks 12.0 [0.47] 14.0 [0.55] Part No. 1393562-8 Ø 12.0 [0.47] 4.8 [0.19] 2.4 [0.09] 3.5 [0.14] 2.1 [0.08] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] 0.8 [0.03] 5.0 [0.20] Soldering aid (sleeve) for jack (1-1393681-9) with solder termination Part No. 2-1393562-2 Cable stripping and installation example: see Part number 2-1393562-2 under “Series 1.0/2.3”, page 130. www.amp.com/communications/com Specifications subject to change. 141 Catalog 1307191 Revised 10-00 RF Coax Connectors Measurement Accessories Between Series Adapters (75 Ohm) Ø 6.5 [0.26] Plug 1.6/5.6 to Plug 1.0/2.3 Ø 10.8 [0.43] 1) 1) 9.2 [0.36] 8.9 [0.35] 28.0 [1.10] Ø 4.1 [0.16] Ø 10.8 [0.43] 9.2 [0.36] 1) 33.0 [1.30] Ø 8.2 [0.32] Ø 10.8 [0.43] Part No. 2-1393670-2 Plug 1.0/2.3 to Jack 1.6/5.6 Coupling Type A, B2, F2 1) Part No. 2-1393670-1 Plug 1.6/5.6 to Jack 1.0/2.3 Coupling Type A, B2, F2 Ø 6.5 [0.26] 8.9 [0.35] Coupling Type A Part No. 2-1393670-3 34.5 [1.36] 1) Detent for jack 2 Only jack side Ø 8.2 [0.32] Ø 4.1 [0.16] Ø 10.8 [0.43] 39.4 [1.55] 142 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Jack 1.0/2.3 to Jack 1.6/5.6 Coupling Type A, B, F www.amp.com/communications/com Part No. 2-1393670-4 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Measurement Accessories (Continued) Between Series Adapters (75 Ohm) (Continued) Ø 14.5 [0.57] Ø 10.8 [0.43] 46.4 [1.83] BNC Plug to Plug 1.6/5.6 Part No. 1-1393665-4 ECN1669-6 BNC Plug to Jack 1.6/5.6 Ø 14.5 [0.57] Ø 8.2 [0.32] 44.3 [1.74] Part No. 1-1393665-6 ECN1670-9 BNC Jack to Plug 1.6/5.6 Ø 14.5 Ø 11.0 Ø 9.6 [0.57] [0.43] [0.38] Ø 10.8 [0.43] 45.4 [1.79] Part No. 1-1393665-7 ECN1671-H M9.0x0.5 [0.35]x[0.02] BNC Jack to Jack 1.6/5.6 Ø 14.5 Ø 11.0 Ø 9.6 [0.57] [0.43] [0.38] Ø 8.2 [0.32] 45.4 [1.79] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Part No. 1-1393665-5 ECN1672-Q www.amp.com/communications/com Specifications subject to change. 143 Catalog 1307191 Revised 10-00 RF Coax Connectors Measurement Accessories (Continued) Termination (75 Ohm) Ø 6.5 [0.26] Standard Termination Plug 1.0/2.3 1) 15.0 [0.59] Coupling Type A 8.9 [0.35] Power W 0.6 Part No. 1-1393665-2 Power W 0.6 Part No. 1-1393665-3 Power W 1.0 Part No. 1393665-1 Power W 1.0 Part No. 1393665-3 Power W 1.0 Part No. 1393665-2 ECN0888-J 1) Detent for jack Ø 4.1 [0.16] 23.1 [0.91] Jack 1.0/2.3 Coupling Type A, B, F Ø 6.5 [0.26] ECN0889-S 29.6 [1.17] Plug 1.6/5.6 Coupling Type A Ø 10.8 [0.43] 28.1 [1.11] Plug 1.6/5.6 Coupling Type D Ø 10.8 [0.43] 27.7 [1.09] 14.3 [0.56] 1.5 [0.06] Ø 8.2 [0.32] Jack 1.6/5.6 Ø 10.8 [0.43] Coupling Type A, B, F M9.0x0.5 [0.35]x[0.02] 144 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Measurement Accessories (Continued) In-Series Adapter (75 Ohm) Adapter 1.6/5.6, Plug/Plug Ø 10.8 [0.43] Coupling Type A 43.8 [1.73] 41.3 [1.63] Part No. 1393681-6 Adapter 1.6/5.6, Plug/Jack Ø 10.8 [0.43] Ø 8.2 [0.32] Coupling Type A, B*, F* Part No. 1-1393681-7 *Jack side only M9.0x0.5 [0.35]x[0.02] 14.3 [0.56] Adapter 1.6/5.6, Jack/Jack Ø 8.2 [0.32] 28.4 [1.12] Ø 10.8 [0.43] M9.0x0.5 [0.35]x[0.02] Coupling Type A, B, F Part No. 1-1393665-1 Note: U- and Y-link connectors see “1.6/5.6” section, page 133. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 145 Catalog 1307191 Revised 10-00 RF Coax Connectors Tools Crimping Tools Crimping tools are used for assembling coaxial connectors on coaxial cables. They can be applied particularly economically for small batch sizes. The crimping dies are a fixed part of the crimping tools. Each tool is equipped with 2 or 3 different profiles. A total of 6 widths across flats are possible with 2 tools, whose hand lengths are adapted to the dimensions of the hexagon profiles. The tools can be distinguished at a glance by different colored handles. Width Across Flats of the Profile 1 2 3 2.8 3.2 3.6 0.11 0.13 0.14 2.8 5.4 4.5 0.11 0.21 0.18 Item Crimping Tool Crimping Tool Dim. L Color of handles Part No. 214.0 8.43 260.0 10.24 Green 1393524-4 Yellow 1393524-5 L 3 50.0 [1.97] Hexagon Profile No. 2 1 6.6 [0.26] with Open Jaws IDC Tool For assembling IDC coaxial connectors Series 1.6/5.6 mS on coaxial cables. Part No. 2-1393524-8 225.0 [8.86] 1.4 [0.04] Removal Tool For replacing the special contacts on connectors DIN 41612 M and SIEDECON. 12.5 [0.49] 70.0 [2.76] 1) 200.0 [7.87] Item Removal tool length 70 [2.76] length 200 [7.87] Spare part Ferrule Part No. 2-1393524-4 2-1393524-6 2-1393524-7 12.5 [0.49] 1) Ferrule (spare part) 146 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Tools (Continued) Setting Gauge Protective Caps/Setting Gauges The setting gauges are used to position coaxial jacks and pre-mating high-current plugs on male connectors DIN 41612 M if the pins are flow-soldered into PC boards. The gauges are held by clamping in connector body and protect the blade contacts. The gauges provide protection — during transport (if the male connectors have already been removed from the packaging), — during assembly, — against soiling, — during soldering. Male Connector DIN 41612M Item Setting gauge for types Setting Gauge PC Board Part No. M 1-1393494-9 M/2 1-1393494-0 M/3 1-1393494-1 Note: These gauges can also be used to protect types C, C/2, C/3 and D. ECN1225-P Wrench Ø 6.7 [0.26] Item Wrench 1.0 [0.04] Part No. 1393488-3 1.0 [0.04] Used to tighten the threaded ring on bulkhead jack 1393670-8. 50.0 [1.97] Ø 6.1 [0.24] Ø 7.3 [0.29] Used to tighten the threaded ring on bulkhead jacks Series 1.0/2.3 50.0 [1.97] Ø 5.6 [0.22] 1.2 [0.05] 1.5 [0.06] Item Wrench Part No. 1393488-4 ECN1229-M 50.0 [1.97] Used to tighten the threaded rings 1-1393562-0 on bulkhead jacks Series 1.6/5.6. 40.0 [1.57] Item Wrench 0.9 [0.04] Part No. 1393524-1 Movable Ø 11.0 Ø 0.91 [0.43] [0.36] 50.0 [1.97] 1.35 [0.05] ECN1230-Q Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 147 Catalog 1307191 Revised 10-00 RF Coax Connectors Coaxial Cables List of the coaxial cables that are listed in the various connector series of this section. 1) 2) Characteristic Impedance (Ω) Max. Cable Outer Diameter (mm) Dielectric Diameter (mm)/ Material1) 50 50 50 50 50 50 50 50 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 1.9 2.1 2.25 2.6 2.8 3.0 3.6 6.4 2.67 3.0 3.3 3.2 3.6 4.0 4.0 4.8 5.0 6.1 6.2 6.25 7.8 9.8 9.8 0.91max/PTFE 0.87/PTFE 1.71max/PTFE 1.60max/PTFE 1.60max/PE 1.52/PTFE 3.01max/PTFE 5.38max/PTFE 1.68max/PTFE 1.60max/PTFE 1.68max/Cell-FEP 2.1max 2.0max/Cell-PE 2.0maxE/Cell-PE 2.54max/PE 2.54max/PE 2.54max/PE 4.25max/PE 2.83max/PE 3.8max/PE 4.43max/PE 6.4/PE 6.4/PE Cable-Type Designation US Designation Manufacturer des. 5YC5Ye 0.3/0.86 RG 178 — RG 196 5YK 0.51/1.68 RG 405 5YC5Ye 0.5/1.5 RG 316 2YCY 0.5/1.5 RG 174 5YCC5Y 0.5/1.5 RD 316 5YK 0.9/3.0 RG 402 5YK 1.63/5.33 RG 401 5YC6Y 0.3/1.6 RG 179 — RD 179 06YCC(St)6Y 0.4/1.6 — — ST 212 02Y(St)CY 0.45/2.0 — 02Y12YC(mS)C6Y 0.45/2.0 — 2YCY 0.4/2.5 — 2YCCY 0.4/2.5 — 2YC(mS)CY 0.4/2.5 — 2YCY 0.7/4.4 — 2YC(mS)CY 0.5/3.0 — 2YCY 0.58/3.7 RG 59 2YCCY 0.7/4.4 — 2YCCY 1.0/6.5 — 2YC(mS)CY 1.0/6.5 — VDE Designation2) IEC Designation 96-IEC 50-1-1 50-1-2 — 50-2-1 — — — — 75-2-1 — — — — — — — — — — — — — — Material label PTFE Polytetrafluorethylene (Teflon) PE Polyethylene FEP Perfluorethylene propylene PFA Perfluoralkoxy copolymer Mounting label of the VDE type numbers (from inside to outside) Example: Explanation Dielectric and Jacket 2Y = PE 5Y = PTFE 02Y = Cell PE 06Y = Cell FEP 6Y = FEP Screen: C = Cu braiding K = Cu tape Specifications on inner conductor: vs = silver plated staku = Bare copper-clad steel wire conductor Intermediate layer: mS = magnetic screen St = static screen 6Y C (mS) C Y Jacket color: gn = green gr = grey rt = red ws = white 0.7/4.0 -75 (r2/100) vs gr Dielectric 1st screen Intermediate layer 2nd screen Outer jacket Diameter inner conductor/dielectric Characteristic impedance Max. reflection (r) in % / frequency in MHz Specifications on inner conductor and/or jacket color 148 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSMP Microminiature Push-On Coaxial Connectors Features Intermateable with Gilbert GPO™ Series ■ DESC approved ■ Enhanced performance features ■ Simplified Assembly Between Series Adapters For OSMP Between Series Adapters, see Pages 255-264. OSMP microminiature push-on coaxial connectors provide solutions for today’s modular designs with denser packaging requirements. The extremely small size of the OSMP offers a versatile solution for high density packaging allowing connector center-to-center spacing of 4.32 [0.17]. The push-on interface facilitates easier assembly and test with a positive snap-in feature to indicate a fully mated connection. The rugged OSMP interface can withstand harsh environments of mechanical shock and vibration, typically found in military or aerospace related applications. This OSMP connector interface is the standard used by Defense Electronics Supply Center (DESC) to generate the SMP push-on connector series. OSMP Shroud and Jack to Jack Adapter Assembly OSMP connectors can be your design solution for mechanical packaging and frequency response. The OSMP interface provides 0.020" of radial misalignment for critical blindmate applications. Mating forces are strictly controlled to ensure reliable connections per mated pair or when simultaneously mating multiple connectors. Cable jacks include an anti-rocking ring to ensure reliable mechanical performance regardless of the operating environment. OSMP connectors offer enhanced broadband VSWR performance of VSWR ■ 1.15:1 max thru 26GHz and 1.40:1 max thru 40GHz. Standard design OSMP configurations include cable connectors, straight and right angle, for 0.047 and 0.085 semi-rigid cable, full detent, limited detent and smooth bore mating shrouds that can be bulkhead or flange mounted and glass feedthroughs for coax to circuit launchers. In-series adapters for module to module intermating and between series adapters for integrating or testing systems or components parameters. 1.50:1 1.40:1 1.30:1 1.20:1 1.10:1 0.0 8.0 16.0 24.0 32.0 40.0 GHz Typical VSWR for OSMP Jack to Jack Adapter Part Numbers 1059829-1 and 1056721-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 149 Catalog 1307191 Revised 10-00 RF Coax Connectors OSMP Microminiature Push-On Coaxial Connectors (Continued) Specifications General Materials and Finishes Housings and Center Contacts Dielectric Shrouds Hermetic Seal Beryllium Copper per ASTM-B-196; gold plate over nickel plate PTFE Fluorocarbon per ASTM-D-1457 Stainless steel per ASTM-A582 Type 303; passivate per ASTM-A380 Glass bead Electrical Frequency Range VSWR Voltage Rating Insertion Loss Insulation Resistance Dielectric Withstanding Voltage RF High Potential Impedance RF Leakage Contact Resistance dc - 40.0 GHz 1.10:1 Maximum dc - 23.0 GHz 1.15:1 Maximum 23.0 - 26.0 GHz 1.40:1 Maximum 26.0 - 40.0 GHz 335 Vrms maximum at sea level 0.10 f√ (GHz) maximum 5000 megohms minimum 500 volts (VRMS minimum) 325 volts (VRMS minimum) @ 5 MHz 50 ohms nominal -80dB to 3 GHz, -65dB from 3 to 26.5 dB minimum Initial center contact 6.0 milliohms maximum Outer contact 2.0 milliohms maximum Mechanical Durability Radial Misalignment Axial Misalignment Force to Engage Force to Disengage Center Contact Retention 100 mating cycles minimum ±0.020 minimum .000/.010 full detent 15.0 lbs. maximum half detent 10.0 lbs. maximum smooth bore 2.0 lbs. maximum full detent 5.0 lbs. minimum half detent 2.0 lbs. minimum smooth bore 0.5 lbs. minimum 1.5 lbs. minimum axial force Environmental Operating Temperature Vibration Shock Thermal Shock Moisture Resistance 150 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 -65°C to +165°C per mil-std-202, method 204, test condition D per mil-std-202, method 213, test condition I per mil-std-202, method 107, test condition B per MIL-STD-202 method 106, except step 7b shall be omitted. Resistance shall be 200 megohms within 5 minutes after removal from humidity. Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSMP Microminiature Push-On Coaxial Connectors (Continued) Interface Dimensions Jack Shroud EMI Ring 3.40 [.132] Min. 3.70 Dia. [.145] Max. Full Detent 2.80 ± .050 [.110 ± .002] 3.43 Dia. [.135] Max. 8.60 ± .076 Dia. [.142 ± .003] Anti-Rock Ring Bullet 2.8 [.112] Min. Smooth Bore 3.43 Dia. [.135] Max. 3.20 ± .050 Dia. [.125 ± .002] Note: The U.S. Government (DESC) has determined that the above specified interface dimensions are interchangeable and intermateble with Gilbert GPO Series RF Connectors.1 1 Per DESC drawing numbers 94007 and 94008, series SMP. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 151 Catalog 1307191 Revised 10-00 RF Coax Connectors OSMP Microminiature Push-On Coaxial Connectors (Continued) Straight Cable Jack, Solder Attachment 6.40 [.250] 3.40 Dia. [.135] Max. 3.40 Dia. [.133] EMI Ring Cable .047 Semi-Rigid .085 Semi-Rigid (RG-405) Right Angle Cable Jack, Solder Attachment Anti-Rock Ring M/A-COM Model Number 2902-7947-62 Part No. 1056526-1 2902-7985-62 1056527-1 5.80 Max. [.230] 4.10 [.161] Max. Dim.B Dim.A EMI Ring Anti-Rock Ring 3.40 Dia. [.135] Max. Cable .047 Semi-Rigid .085 Semi-Rigid (RG-405) Jack to Jack Adapter (Bullet) Dim. A 4.8 .190 5.3 .209 Dim. B 5.8 .230 6.7 .265 2908-7947-62 1056553-1 2908-7985-62 1056554-1 3.40 Dia. [.135] Max. M/A-COM Model Number 2980-0000-62 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 6.40 / 6.50 [.2525 / .2555] 3.40 Dia. [.133] 152 M/A-COM Model No. Dimensions are in millimeters over [inches] Part No. 1059829-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSMP Microminiature Push-On Coaxial Connectors (Continued) Shroud - Threaded 3.00 [.120] Description Full Detent Limited Detent Smooth Bore Shroud - 2 Hole Flange Surface Mount 4.10 Dia. [.160] Max. M/A-COM Model No. 2998-5045-02 2998-5043-02 2998-5044-02 Part No. 1056745-1 1056743-1 1056744-1 3.00 [.120] Dim.C 4.20 [.165] Dim.B Dim.A Dim.D 2 Plcs. Description Full Detent Limited Detent Smooth Bore 1.10 [.045] Dim. A Dim. B Dim. C Dim. D M/A-COM Model No. Part No. 12.2 .480 8.3 .328 4.7 .187 2.5 .098 2998-5001-02 1056721-1 15.8 .625 12.2 .481 5.7 .223 2.6 .102 2998-5002-02 1056722-1 10.2 .400 7.2 .282 4.2 .165 1.9 .073 2998-5003-02 1056724-1 12.2 .480 8.3 .328 4.7 .187 2.5 .098 2998-5028-02 1056729-1 10.2 .400 7.2 .282 4.2 .165 1.9 .073 2998-5030-02 1056731-1 10.2 .400 7.2 .282 4.2 .165 1.9 .073 2998-5049-02 1056749-1 Shroud - Press Fit Dim.B Dim.A Description Full Detent Limited Detent Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Dim. A 4.6 .182 4.4 .174 3.9 .154 Dim. B 2.9 .115 3.0 .120 2.0 .080 M/A-COM Model No. Part No. 2998-5005-02 1056726-1 2998-5033-02 1056734-1 2998-5035-02 1056736-1 www.amp.com/communications/com Specifications subject to change. 153 Catalog 1307191 Revised 10-00 RF Coax Connectors OSMP Microminiature Push-On Coaxial Connectors (Continued) Shroud - Solder-In Hermetic 3.60 [.140] 2.00 [.080] 1.30 [.050] 0.40 Dia. [.015] 3.70 [.145] Dia. 2.50 Dia. [.098] Glass Bead Assembly 1.60 [.063] Description Full Detent Limited Detent Smooth Bore M/A-COM Model No. 2998-5054-94 2998-5055-94 2998-5056-94 2.50 [.099] M/A-COM Model Number 2998-5022-94 .400 [.015] Dia. 154 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 1056750-1 1056751-1 1056752-1 Part No. 1056728-1 3.20 [.125] Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Blind Mate Connectors Features ■ ■ ■ ■ ■ ■ ■ ■ 26.5 or 40 GHz performance Superior performance of air dielectric interface Solid telescoping alignment; no interface damage Shielded outer contact; low RF leakage Configurations include bulkhead jacks and plugs for panel and bulkhead applications 3.5 mm Blind Mate has interchangeable mounting/ panel spacing with other blind mate designs per DESC specification Crimped with standard military SMA hand tool and special locator inserts Listed under the Component Program of Underwriters Laboratories Inc., File No. E81956 Recognized under the Component Program of Underwriters Laboratories Inc., File No. E81956 Certified by Canadian Standards Association File No. LR 7189 R ■ R ■ R Packaging — All connectors are packaged individually unless otherwise noted. Materials Electrical Characteristics Center Contacts — Beryllium Copper or Brass per QQ-B-626, per QQ-C-530, gold plated Outer Contacts — Beryllium copper per QQ-C-530, gold plated Plugs — Beryllium copper per QQ-C-530, gold plated Jack — Stainless steel per ASTM-A-582, gold plated Shells — Stainless steel per ASTM-A-582, passivated Panel Shells — Brass per QQ-B-626, nickel plated Dielectrics — TEFLON per ASTM-D-1457 Grip Rings — Brass per MIL-C-50 or Beryllium Copper per QQ-C-530, nickel plated Springs — Steel wire per QQ-W-470 Bushings — Stainless steel per ASTM-A-582, passivated Retention Springs — Beryllium Copper per QQ-C-530, Tin-Lead Plated Nominal Impedance — 50 ohms Frequency Range — 3.5 mm: 0 to 26.5 GHz 2.8 mm: 0 to 26.5 GHz 2.8 mm for size 8 cavities: 0 to 40 GHz Operating Voltage — RG-402/U Cable (3.58 [.141] O.D.) 500 volts rms at 60 Hz (sea level) 125 volts rms at 60 Hz (21 336 m [70,000 ft]) RG-405/U Cable (2.18 [.086] O.D.) 335 volts rms at 60 Hz (sea level) 85 volts rms at 60 Hz (21 336 m [70,000 ft]) Finishes Environmental Characteristics Passivate per QQ-P-35 Gold per MIL-G-45204 Nickel per QQ-N-290 Tin-Lead per ASTM-B-545 Temperature Range — -65°C to +105°C Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Mechanical Characteristics Cable Retention — RG-402/U Cable (3.58 [.141] O.D.)– 60 lb [266.9 N], min. RG-405/U Cable (2.18 [.086] O.D.)– 30 lb [133.4 N], min. Connector Mating Force — 3.5 mm: 6 lbs Max. 2.8 mm: 3 lbs Max. www.amp.com/communications/com Specifications subject to change. 155 Catalog 1307191 Revised 10-00 RF Coax Connectors 3.5 mm Blind Mate Connectors Bulkhead Plug 2-Hole Panel Plug 2.74 ±0.05 Dia. [.108 ±.002 ] (2 Holes) 9.91 ±0.05 Dia. [.390 ±.002 ] 14.22 ±0.1 [.560 ±.004 ] 19.05 [.750] 10.41 [.410] Dia. 11.68 Dia. [.460] 14.99 Max. [.590] 15.11 Max. [.595] Maximum Panel Thickness 3.81 [.150] 9.58 ±0.05 Dia. [.377 ±.002 ] 7.11 ±0.05 Typ. [.280 ±.002 ] Recommended Panel Cutout Maximum Panel Thickness 4.83 [.190] Recommended Panel Cutout Bulkhead Jack 6.15/6.17 Dia. [.242/.243] 7.92 Hex [.312] 14.48 Max. [.570] 6.5 ± 0.05 Dia. [.256 ± .002] BMA Mount BMB Mount Maximum Panel Thickness 3.18 [.125] Recommended Panel Cutouts RG/U Cable Part No. 2-332004-0 Part No. *** — 447314-1 *** — 447315-1 316 Double Braid 2-Hole Panel Plug Bulkhead Jack (BMA Mount Cutout) Bulkhead Plug ** — 1274113-1 402 Semi-Rigid/ 3.58 [.141] 2-Hole Panel Plug 312253-1 313745-1 222200-1 405 Semi-Rigid/ 2.18 [.086] Bulkhead Plug Bulkhead Jack (BMB Mount Cutout) 312253-2 313745-1 222197-1 312253-2 313746-1 222196-1 Lockwasher and Jam Nut Part No. 1-22145-3 Hand Tool Kit No. 59981-1 Die Set Locator* Connector Configuration 174, 188, 316 *Not included in Hand Tool Kit No. 59981-1; must be purchased separately. **See drawing for tooling information. ***Use hand tool 220061-1 to crimp contact and ferrule. 5.08 ± .050 [.200 ± .002] Right Angle PC Board Bulkhead Jack 9.65 Max. [.380] 2.54 ± .076 [.100 ± .003] 1.70 ± .076 Dia. [.067 ± .003] 2.79 – 2.87 [.110 – .113] 3.94 [.155] 5.08 ± .050 [.200 ± .002] 6.35 [.250] 2.54 ± .050 [.100 ± .002] 6.45 ± .050 Dia. [.254 ± .002] 1.52 ± .076 Dia. [.060 ± .003] Part No. 448089-1 156 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Recommended PCB Layout Recommended Panel Cutout www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors 2.8 mm Blind Mate Connectors 2.8 mm Floating Plug Bottoming Surface 3.81 Min. [.150] Typ. Materials and Finishes Center Contact — Beryllium copper, gold plated Outer Shell — Stainless steel, passivated Inner Shell — Beryllium copper, gold plated Dielectric — TEFLON Grip Ring — Beryllium copper or brass, nickel plated Spring — Steel wire Retaining Clip — Beryllium copper, nickel plated Shroud — Beryllium copper, nickel plated 5.16 ±0.05 [.203 ±.002] 7.62 Min. [.300] Typ. 7.24 ±0.08 Dia. [.285 ±.003] 11.05 Max. [.435] RG-405 Semi-Rigid Cable - Part No. 413012-1 1.19 [.047] Semi-Rigid Cable - Part No. 413025-1 Bulkhead Jack 2.36 ±0.05 [.093 ±.002] 6.73 ±0.03 Dia. [.265 ±.001] Typ. Recommended Panel Layout Bottoming Surface 1.98 ±0.05 [.078 ±.002] 7.62 Min. [.300] Typ. Material and Finishes Center Contact — Beryllium copper, gold plated Inner Shell — Beryllium copper, gold plated Dielectric — TEFLON Grip Ring — Beryllium copper or brass, nickel plated Shroud — Beryllium copper, gold plated 4.75 Hex [.187] 10.42 Max. [.410] 2.36 [.093] 4.9 ±0.05 [.193 ±.002] 1.19 [.047] Semi-Rigid Cable - Part No. 413024-1 4.09 ±0.03 Dia. [.161 ±.001] Typ. Recommended Panel Layout Launcher Bottoming Surface 5.08 Min. [.200] 1.52 [.060] Materials and Finishes Center Contact — Brass, gold plated Inner Shell — Beryllium copper, gold plated 4.75 Hex [.187] 10.16 Max. [.400] 7.62 Min. [.300] Typ. 6-40 UNF-2B Typ. 3.96 [.156] Part No. 413020-1 1.8 ±0.05 [.071 ±.002] Recommended Panel Layout Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 157 Catalog 1307191 Revised 10-00 RF Coax Connectors 2.8 mm Blind Mate Contacts for Size 8 Cavities (for Subminiature D Type Connectors) Plug Materials and Finishes Shroud and Grip Ring — Brass, nickel plated Retaining Clip — Beryllium copper, gold plated Shell and Contact — Beryllium copper, gold plated Dielectric — TEFLON 5.72 Dia. [.225] Max. 13.85 [.545] Max. RG-405 Semi-Rigid/2.18 [.086] Cable Part No. 413242-1 Jack Materials and Finishes Sleeve and Grip Ring — Brass, nickel plated Retaining Clip — Beryllium copper, nickel plated Shell and Contact — Beryllium copper, gold plated Dielectric — TEFLON Application Tool — 59980-1 (Requires Die Set and Locator, see table for part numbers) Trimmer Tool — 312317-1 Cable Dressing Fixture — 311395-1 5.72 Dia. [.225] Max. 13.75 Max. [.541] RG-405 Semi-Rigid/2.18 [.086] Cable Part No. 413249-1 Note: All the above tools are included in Hand Tool Kit No. 59981-1 listed in the table. RG/U Cable Connector Configuration 405 Semi-Rigid 2.18 [.086] Plug Jack Hand Tool Kit No. 59981-1 Die Set Locator* 312253-2 312253-2 852113-1 852114-1 Part No. 413242-1 413249-1 *Not included in Hand Tool Kit No. 59981-1; must be purchased separately. 158 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors Features ■ Interface designed for multiple interconnects ■ For high performance microwave system requirements ■ Bulkhead or panel mount ■ For semi-rigid cable OSP miniature connectors for semi-rigid cable meet high performance requirements for microwave multiple interconnects. Standard units are available in bulkhead or panel mount designs for either direct solder or OSCC solderless compression crimp attachment. Complete tooling for both versions is located in the Tool Section of this catalog. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Jack connectors are available in either float or rigid mount. Rigid mount units will function to specifications up to ±.10 [.004] radial misalignment with the mating plug connector. Applications requiring greater than ±.10 [.004 ] radial misalignment can use either the float design or floating connector plates with guide pins. The OSCC Solderless Compression Crimp attach- ment meets high performance requirements for microwave system applications. The cable attachment is permanent and highly reliable. Ease of assembly permits users unskilled in soldering techniques to rapidly produce cable assemblies with consistently excellent mechanical and electrical performance. www.amp.com/communications/com Specifications subject to change. 159 Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) The specifications given refer specifically to mated pair of Part Numbers 1059410-1 and 1059402-1 (RG 402) and 1059412-1 and 1222092-1 (RG 405). Specifications on other connectors are available on request. The general electrical, mechanical and environmental specifications in the following table are recommended for procurement documents or drawings. Engineering Data Impedance — Frequency — Temperature Rating — 50 ohms dc to 22.0 GHz -65° to 125° C Electrical RG 402 (.141) Semi-Rigid RG 405 (.085) Semi-Rigid 1.02 + .005f (GHz) 1.02 + .008f (GHz) -.03 x √ f (GHz) 5,000 megohms min. 1.05 + .005f (GHz) 1.05 + .009f (GHz) -.03 x √ f (GHz) 5,000 megohms min. VSWR — dc - 18.0 GHz 18.0 - 22.0 GHz RF Transmission Loss — Insulation Resistance — Contact Resistance — Center Contact Outer Contact Outer Contact to Cable Dielectric Withstanding Voltage — Corona Extinction Voltage at 70,000 Ft.— RF High Potential at 5 MHz — RF Leakage Interface Only — Power Handling — 2.0 milliohms max. 2.0 milliohms max. 2.0 milliohms max. 2.0 milliohms max. 0.5 milliohms max. 0.5 milliohms max. 1500 volts RMS 1000 volts RMS 375 volts min. 335 volts min. 1,000 volts RMS 670 volts RMS -(90-fGHz) dB min. (fully mated) -(90-fGHz) dB min. (fully mated) 300W at 3 GHz (sea level) and room temperature Environmental Corrosion — Vibration — Shock — Temperature Cycling — Moisture Resistance — Method 101, Condition B, MIL-STD-202 Method 204, Condition D, 20G’s, MIL-STD-202 Method 213, Condition I, 100G’s, MIL-STD-202 Method 107, Condition B, MIL-STD-202 Method 106, MIL-STD-202 Material Housing — Center Contact — Dielectric — Gasket (O’Ring) — Corrosion resistant steel Type 303 (stainless) per ASTM A484 and A582 Beryllium copper per ASTM-B-196 TFE fluorocarbon per ASTM-D-1457 MIL-P-25732 Mechanical Force to Engage — Force to Disengage — Center Contact Retention — Durablilty — Radial Misalignment — Rigid Mount Float Mount 3 pounds max. 1.5 pounds max. 6 pounds min. 5,000 Cycles ±.10 [±. 004] ±.51 [±.020] Mating Characteristics Jack Connector — Center Contact Socket Insertion Force Withdrawal Force Oversize test Pin — Test Pin Finish — Insertion Depth — Number of Insertions — Test Pin — Test Pin Finish — Insertion Depth — Insertion Force — Test Pin — Test Pin Finish — Insertion Depth — Withdrawal — .945 + .003 [.0372 + .0001] dia. 16 micro inch .76/1.14 [.030/.045] 3 .940 + .003 [.0370 + .0001] dia. 16 micro inch 1.27/1.91 [.050/.075] 3 pounds max. .90 + .003 [.0355 - .0001] dia. 16 micro inch 1.27/1.91 [.050/.075] 1 ounce min. Finish Center Contact — Housing — Gold plate per MIL-G-45204, Type II, Class 1 over copper plate per MIL-C-14550 Gold plate per MIL-G-45204, Typ II, Class 0 over nickel plate per QQ-N-290, Class 2 or passivate per ASTM-A380 All dimensions shown are nominal. Contact the factory for specific tolerances. 160 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) Interface Mating Dimensions The connector interface, specifically designed for multiple interconnects, maintains reliable performance over the typical mechanical tolerance required in cost effective packaging. The interface test data shows excellent performance is maintained with mating gaps up to 0.38 [.015]. Jack Letter A B C D E F Dimensions 1.78 .070 Nom. 5.72 .225 Min. 7.62 Ref. .300 5.00 Nom.* .197 5.08 .200 Max. 3.23 Max.* .127 Plug Letter A B C D E F Dimensions 1.78 .070 Nom. 5.33 .210 Nom. 7.62 Ref. .300 5.05 Min. .199 0.91 .036 Nom. 3.25 Min. .128 *With spring bottomed Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 161 Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) For Semi-Rigid Cable, 2.16 [.085] and 3.58 [.141] Dia., Direct Solder Attachment 7.9 Hex. A [.312] Dia. 6.1 ± 0.03 Dia. [.240 ± .001] Bulkhead Feedthrough Cable Plug Rear Mount 17.5 [.690] nded Hole Cable Bulkhead Feedthrough Cable Jack Rigid Rear Mount Dimensions 6.1 + 0.03 – .000 Dia. [.242 + .001] – .000 Recommended Mounting Hole M/A-COM Model No. Part No. 4.6 .180 4503-7941-00 1059402-1 3.0 .120 4503-7985-00 1222092-1 A B Gold 3.7 .144 Gold 2.3 .089 6.4 A Dia. Dia. [.250] 11.1 [.437] 11.1 Hex. [.437] 18.0 [.710] ded ole Cable 5 3 2] 1 9.19 Max. [.362] B Dia. Dimensions Plating RG-402/U 3.58 .141 RG-405/U 2.16 .085 Flange Mount Cable Jack Floating Rear Mount 9.19 Max. [.362] B Dia. Plating RG-402/U 3.58 .141 RG-405/U 2.16 .085 6.1 [.240 Recommended Mounting Hole Part No. 4.6 .180 4504-7941-00 1059410-1 3.0 .120 4504-7985-00 1059412-1 B Gold 3.7 .144 Gold 2.3 .089 2.6 Dia. [.102] 2 Plcs. 9.5 Dia. [.372] – .000 M/A-COM Model No. A Dia. 9.1 + 0.03 – .000 Dia. [.359 + .001] 19.1 Dia. [.750] B Dia. 14.2 ± 0.10 [.560 ± .004] 9.6 + 0.05 – 0.03 D [.377 + .002] – .001 9 [.3 14.2 [.560] A Dia. 18.0 [.710] Cable RG-402/U 3.58 .141 RG-405/U 2.16 .085 9.7 [.380] Dimensions 7.1 [.280] Recommended Mounting Hole M/A-COM Model No. Part No. A B 3.7 .144 4.6 .180 4506-7941-02 1221879-1 2.3 .089 3.0 .120 4506-7985-02 1059456-1 Finish: Inner housing that is soldered to cable is gold plated. Outer housing is passivated stainless steel. When using semi-rigid cable, it is recommended that a service loop be used to facilitate the float features of the connector. 162 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) For Semi-Rigid Cable, 2.16 [.085] and 3.58 [.141] Dia., Direct Solder Attachment (Continued) A 11.2 Dia. Dia. [.440] Max. 9.3 ± 0.03 Dia. [.365 ± .001] Low Profile – Bulkhead Feedthrough Cable Jack – Floating Rear Mount 16.2 [.640] Cable RG-402/U 3.58 .141 RG-405/U 2.16 .085 Plating 9.4 + 0.05 – 0.03 Dia. [.368 + .002] B Dia. – .001 Recommended Mounting Hole Dimensions M/A-COM Model No. Part No. 4.6 .180 4522-7941-02 1059505-1 3.0 .120 4522-7985-02 1044851-1 A B Gold 3.7 .144 Gold 2.3 .089 When using semi-rigid cable, it is recommended that a service loop be used to facilitate the float features of the connector. Low Profile – Panel Feedthrough Cable Jack – Floating Rear Mount 7.6 Dia. [.300] A Dia. 18.0 [.710] Cable RG-402/U 3.58 .141 RG-405/U 2.16 .085 Plating B Dia. Dimensions M/A-COM Model No. Part No. 4.6 .180 4510-7941-00 1059465-1 3.0 .120 4510-7985-00 1059467-1 A B Gold 3.7 .144 Gold 2.3 .089 Recommended removal tool part number 1059774-1 is described in Tool Section. When using semi-rigid cable, it is recommended that a service loop be used to facilitate the float features of the connector. Stand-Off C Panel A Panel B 8.6 + 0.08 – 0.00 [.340 + .003] 8.0 + 0.05 – 0.00 [.316 + .002] – .000 – .000 Panel B 1.3 + 0.00 – 0.13 [.050 + .000] – .005 Panel A ±.003 2.3 .090 2.3 .090 2.3 .090 3.2 .125 3.2 .125 3.2 .125 Panel B ±.003 9.5 .375 11.1 .438 12.7 .500 9.5 .375 11.1 .438 12.7 .500 Stand-Off Panel C +.050/–.000 7.2 .285 5.6 .222 4.1 .160 6.4 .250 4.7 .187 3.2 .125 Recommended Mounting Detail Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 163 Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) For Semi-Rigid Cable, 2.16 [.085] and 3.58 [.141] Dia., OSCC Solderless Compression Crimp Attachment Bulkhead Feedthrough Cable Plug Fixed Rear Mount 7.9 A Hex. Dia. [.312] 6.1 ± 0.03 Dia. [.240 ± .001] 6 [.2 d e Cable Plating Dim. A RG-405/U 2.16 .085 Passivated Stainless Steel 2.2 .088 6.1 + 0.03 – .000 Dia. [.242 + .001] 9.19 Max. [.362] 5.5 Dia. [.218] B – .000 Recommended Mounting Hole Dim. B Before After Crimping Crimping 19.8 .782 17.2 .677 M/A-COM Model No. Part No. 4503-7685-02 1059399-1 Outline drawing shows after crimp dimensions. A 6.4 Dia. [.250] Dia. Bulkhead Feedthrough Cable Jack Fixed Rear Mount 11 [.43 11.1 Hex. [.437] 9.1 + 0.03 5.5 Dia. [.218] B – .000 12.7 Max. [.500] [.359 + .001] Dia. – .000 ed le Recommended Mounting Hole Dim. B Before After Crimping Crimping Cable Plating Dim. A RG-402/U 3.58 .141 RG-405/U 2.16 .085 Passivated Stainless Steel Passivated Stainless Steel 3.6 .143 21.1 .830 2.2 .088 21.1 .830 M/A-COM Model No. Part No. 18.2 .715 4504-7641-02 1059408-1 18.2 .715 4504-7685-02 1059409-1 Outline drawing shows after crimp dimensions. Flange Mount Cable Jack Floating Rear Mount 2.6 Dia. [.102] 2 Plcs. Dia. 9.5 Dia. [.372] 19.1 Dia. [.750] 5.5 Dia. [.218] 14.2 ± 0.10 [.560 ± .004] 9.6 + 0.05 – 0.03 Dia. [.377 + .002] – .001 9.5 [.372 14.2 [.560] A Dia. B 7.1 [.280] 9.7 [.380] Recommended Mounting Hole Dim. B Before After Crimping Crimping Cable Plating Dim. A RG-402/U 3.58 .141 RG-405/U 2.16 .085 Passivated Stainless Steel Passivated Stainless Steel 3.6 .143 22.6 .891 2.2 .088 22.6 .891 M/A-COM Model No. Part No. 19.8 .780 4506-7641-02 1059451-1 19.8 .780 4506-7685-02 1059452-1 Outline drawing shows after crimp dimensions. When using semi-rigid cable, it is recommended that a service loop be used to facilitate the float features of the connector. 164 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) For Flexible Cable, Crimp Attachment 6.9 ± 0.03 Dia. [.240 ± .001] Bulkhead Feedthrough Cable Plug Rear Mount 11.4 [.447] 6.1 + 0.03 – .000 Dia. [.242 + .001] 21.2 Ref. [.833] ded Hole 11 [.44 – .000 Recommended Mounting Hole 34.9 Max. [1.375] Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4533-7341-02 1059521-1 Passivated Stainless Steel 4533-7388-02 1059523-1 Cable RG-55/U, 142, 223, 400 RG-174/U, 179, 187, 188, 316 6.9 [.240 9.1 ± 0.03 Dia. [.357 ± .001] Bulkhead Feedthrough Cable Jack Rigid Rear Mount 9.1 + 0.03 – .000 Dia. [.359 + .001] 6.4 [.250] – .000 21.7 Ref. [.855] Recommended Mounting Hole 35.6 Max. [1.400] Cable Plating M/A-COM Model No. Part No. RG-55/U, 142, 223, 400 Passivated Stainless Steel 4534-7341-02 1059525-1 2.6 Dia. [.102] 2 Plcs. Dia. Flange Mount Cable Jack Floating Rear Mount 9.6 + .051 – .025 Dia. [.377 + .002] – .001 9.5 [.372] Dia. 14.2 [.560] 21.7 Ref. [.875] 9.5 [.375] 35.6 Max. [1.400] Cable RG-55/U, 142, 223, 400 RG-174/U, 179, 187, 188, 316 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 19.1 [.750] Dia. 9.5 [.372 Dia 14.2 ± .102 [.560 ± .004] 7.1 [.280] Recommended Mounting Hole Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4536-7341-02 1059540-1 Passivated Stainless Steel 4536-7388-02 1059541-1 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 165 Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) For Flexible Cable, Crimp Attachment (Continued) Low Profile – Panel Feedthrough Cable Jack – Rear Mount 7.6 [.300] Dia. 9.4 + 0.05 – 0.03 Dia. [.368 + .002] – .001 22.3 Ref. [.878] 35.6 Max. [1.400] Cable RG-55/U, 142, 223, 400 RG-174/U, 179, 187, 188, 316 Recommended Mounting Hole Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4540-7341-02 1059550-1 Passivated Stainless Steel 4540-7388-02 1059551-1 Refer to Recommended Mounting Hole Detail for Semi-Rigid Cable Low Profile Feedthrough Cable Jack. Recommended removal tool part number 1059774-1 is described in Tool Section. 166 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) Panel Mount Straight Terminal 2-Hole Flange Mount Plug Receptacle 6.4 Dia. [.250] 2.6 Dia. 12.2 [.102] [.481] 2 Plcs. 1.3 .050 Dia. 15.9 [.625] 1.7 [.065] 4.1 Dia. [.162] 9.9 [.390] 22.3 [.878] 6.6 [.260] 8.4 [.330] 2-Hole Flange Mount Jack Receptacle 2.6 Dia. [.102] 2 Plcs. 15.9 [.625] 1.3 Dia. [.050] 12.2 [.481] 4.1 Dia. [.162] 27.4 [1.080] 4-Hole Flange Mount Plug Receptacle M/A-COM Model No. Part No. Passivated Stainless Steel 4551-1352-02 1049678-1 Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4552-1352-02 1059596-1 Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4551-1201-02 1329846-1 Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4552-1201-02 1059594-1 7.6 [.300] 2.6 Dia. [.102] 2 Plcs. 6.4 Dia. [.250] 1.3 Dia. [.050] 4.1 Dia. [.162] 22.3 [.878] 8.6 [.340] Typ. 12.7 [.500] Sq. 4-Hole Flange Mount Jack Receptacle 2.6 Dia. [.102] 2 Plcs. 1.3 Dia. [.050] 27.4 [1.080] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Plating 4.1 Dia. [.162] 12.7 [.500] Sq. Dimensions are in millimeters over [inches] 8.6 [.340] Typ. www.amp.com/communications/com Specifications subject to change. 167 Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) Panel Mount (Continued) Straight Terminal Threaded Installation – Panel Feedthrough Plug Receptacle 0.5 Dia. [.020] 1.6 Dia. [.064] 5.3 Dia. 10.4 [.410] [.210] 5.5 ± 0.03 Dia. [.218 ± .001] 1.7 ± 0.03 Dia. [.066 ± .001] 5.3 ± 0.05 [.210 ± .002] 6.4 Panel [.250] Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4557-5009-02 1081242-1 Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4558-5009-02 1059657-1 Recommended Mounting Hole Threaded Installation – Panel Feedthrough Jack Receptacle 0.5 Dia. [.020] 1.6 Dia. [.064] 5.3 Dia. 10.4 [.410] [.210] 5.5 ± 0.03 Dia. [.218 ± .001] 1.7 ± 0.03 Dia. [.066 ± .001] 5.3 ± 0.05 [.210 ± .002] 6.4 Panel [.250] Recommended Mounting Hole Press Fit Installation – Panel Feedthrough Plug Receptacle 0.5 Dia. [.020] 7.6 Dia. [.300] 6.4 + 0.05 – .000 Dia. [.253 + .002] – .000 7.92 Dia. [.312] 6.3 + .000 – 0.05 Dia. [.248 + .000] – .002 1.2 ± 0.03 Dia. [.046 ± .001] 6.4 ± 0.03 Dia. [.250 ± .001] 6.4 [.250] Recommended Mounting Hole Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4557-1154-02 1059610-1 Press Fit Installation – Panel Feedthrough Jack Receptacle 0.5 Dia. [.020] 7.6 Dia. [.300] 6.4 + 0.05 – .000 Dia. [.253 + .002] – .000 1.2 ± 0.03 Dia. [.046 ± .001] 6.4 ± 0.03 Dia. [.250 ± .001] 6.3 + .000 6.4 – 0.05 Dia. [.250] [.248 + .000] – .002 Recommended Mounting Hole 168 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Plating M/A-COM Model No. Part No. Passivated Stainless Steel 4558-1154-02 1059654-1 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) Panel Mount (Continued) Straight Terminal Printed Circuit Board Straight Plug Receptacle – Captured Contact 1.7 + 0.08 – .000 Dia. [.067 + .003] Hole Typ. – .000 1.0 Sq. [.040] 4 Plcs. Plating 12.7 [.500] 1.3 Dia. [.050] 5.1 [.200] Typ. 6.4 [.250] Sq. 5.1 [.200] Typ. Gold M/A-COM Model No. 4563-0000-00 Part No. 1059684-1 M/A-COM Model No. 4562-0000-00 Part No. 1059681-1 M/A-COM Model No. 4565-0000-00 Part No. 1059691-1 Recommended Mounting Hole Straight Jack Receptacle – Captured Contact 1.7 + 0.08 – .000 Dia. [.067 + .003] Hole Typ. – .000 1.0 Sq. [.040] 4 Plcs. 1.3 Dia. [.050] Plating 5.1 [.200] Typ. 9.5 [.375] Dia. 13.5 [.530] Gold 5.1 [.200] Typ. Recommended Mounting Hole Right Angle Plug Receptacle – Captured Contact 13.5 [.530] 1.7 + 0.08 – .000 Dia. [.067 + .003] Hole Typ. – .000 1.0 Sq. [.040] 4 Plcs. Plating 15.0 [.590] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 1.3 Dia. [.050] 6.4 [.250] Sq. Dimensions are in millimeters over [inches] 5.1 [.200] Typ. 5.1 [.200] Typ. Gold Recommended Mounting Hole www.amp.com/communications/com Specifications subject to change. 169 Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) Hermetically Sealed Metal-To-Metal Rigid Gasket Seal – Panel Feedthrough Plug Receptacle 0.5 Dia. [.020] 5.3 Dia. [.210] 10.4 [.410] VSWR (GHz) 1.04 + .009f RF Leakage (dB) –(90-fGHz) Rigid Gasket 1.6 [.064] Dia. Plating Passivated stainless steel M/A-COM Model No. 4557-5119-02 Part No. 1059632-1 M/A-COM Model No. 4558-5119-02 Part No. 1059665-1 Installation Thermal Limit: 250°C. Recommended Mounting Hole Detail A follows, pg 171. Rigid Gasket Seal – Panel Feedthrough Jack Receptacle 0.5 Dia. [.020] 1.6 [.064] Dia. 11.2 [.450] VSWR (GHz) 1.04 + .009f RF Leakage (dB) –(90-fGHz) 5.3 Dia. [.210] Rigid Gasket Plating Passivated stainless steel Installation Thermal Limit: 250°C. Recommended Mounting Hole Detail A follows, pg 171. Field Replaceable Solder and Braze-In Panel Feedthrough Plug Receptacle 4.0 + 0.05 – 0.03 Dia. [.158 + .002] 5.3 Dia. [.210] – .001 9.9 [.390] 5.6 ± 0.13 [.220 ± .005] 0.5 ± 0.03 Dia. [.020 ± .001] Glass Seal VSWR (GHz) 1.06 + .01f RF Leakage (dB) –(90-fGHz) Plating Passivated stainless steel M/A-COM Model No. 4557-5329-02 Part No. 1059637-1 Recommended Mounting Detail B or E follows, pg 171. 170 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSP Miniature Modular Blind Mate Connectors (Continued) Hermetically Sealed (Continued) Field Replaceable Solder and Braze-In (Continued) Panel Feedthrough Jack Receptacle 4.0 + 0.05 – 0.03 Dia. [.158 + .002] – .001 10.7 [.421] VSWR (GHz) 1.06 + .01f RF Leakage (dB) –(90-fGHz) 0.5 ± 0.03 Dia. [.020 ± .001] 5.6 ± 0.13 [.220 ± .005] Glass Seal M/A-COM Model No. 4558-5329-02 Plating Passivated stainless steel Part No. 1059671-1 Recommended Mounting Detail B or E follows at bottom of this page. 2-Hole Flange Mount Plug Receptacle With EMI/RFI Gasket – 0.5 [.018] Dia. Contact 6.4 Dia. [.250] 2.8 + 0.05 – 0.03 [.112 + .002] – .001 2.6 Dia. [.102] 2 Plcs. 15.9 [.625] Dia. 12.2 [.481] 9.5 [.375] VSWR (GHz) 1.06 + .01f RF Leakage (dB) –(90-fGHz) 8.0 ± 0.13 [.315 ± .005] 0.5 ± 0.03 [.018 ± .001] Dia. Plating Passivated stainless steel 6.6 [.260] M/A-COM Model No. 4551-3357-02 Part No. 1059572-1 Recommended Mounting Detail D follows at bottom of this page. Recommended Mounting Hole Detail Detail A* Detail B* (6.35 [.250] Panel Thickness) 5.5 ± 0.03 [.218 ± .001] Dia. 1.7 ± 0.03 [.066 ± .001] Dia. 6.4 [.250] Ref. Panel .000 4.1 +– 0.05 Dia. .000 [.162 +– .002 ] 5.5 ± 0.03 [.218 ± .001] Dia. 6.4 ± 0.08 [.250 ± .003] Ref. Panel Detail D* Detail C* 3.2 ± 0.13 [.125 ± .005] Panel 2.6 ± 0.03 [.102 ± .001] Dia. Detail E* 3.2 ± 0.13 [.125 ± .005] Panel 12.2 [.481] Ref. 2.9 ± 0.03 [.115 ± .001] Dia. 5.5 ± 0.03 [.218 ± .001] Dia. 12.2 [.481] Ref. 7.6 ± 0.08 [.300 ± .003] Ref. Panel 3.2 ± 0.03 [.125 ± .001] .000 4.1 +– 0.03 Dia. .000 [.162 +– .001 ] *Consult appropriate Instruction Sheet for complete mounting details. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 171 Catalog 1307191 Revised 10-00 RF Coax Connectors OSSP Subminiature Modular Blind Mate Connectors Features ■ Subminiature version of OSP Blind Mate Connectors ■ For space savings ■ Family of connectors and adapters OSSP connectors are a subminiature version of the OSP blind mate series. Connectors in this series incorporate the design elements of the OSP interface including the float and mismate features. OSSP blind mates are about 40% smaller than OSPs and are Engineering Data A complete family of OSSP connectors and adapters is available including cable connectors, fixed and float mount panel connectors and hermetic connectors. Rigid mount units will func- tion to specifications up to ±.064 [±.0025] radial misalignment with the mating plug connector. Applications requiring greater than ±.064 [±.0025] radial misalignment can use either the float design or floating connector plates with guide pins. Mechanical Impedance — Frequency — Temperature Rating — 50 ohms dc to 28.0 GHz -65° to 125° C Electrical RG-405 (.085) Semi-Rigid VSWR — RF Transmission Loss — Insulation Resistance — Contact Resistance — Center Contact Outer Contact Outer Contact to Cable Dielectric Withstanding Voltage — Corona Extinction Voltage at 70,000 Ft.— RF High Potential at 5 MHz — RF Leakage Interface Only — Power Handling — 1.05 + .01f (GHz) -.040 x √ f (GHz) 5,000 megohms min. 6.0 milliohms max. 3.0 milliohms max. 0.5 milliohms max. 675 volts RMS 250 volts min. 675 volts RMS -(90-fGHz) dB min. (fully mated) 300W at 3 GHz (sea level) and room temperature Environmental Corrosion — Vibration — Shock — Temperature Cycling — Moisture Resistance — designed to be used in applications where space is at a premium. Method 101, Condition B, MIL-STD-202 Method 204, Condition D, 20G’s, MIL-STD-202 Method 213, Condition I, 100G’s, MIL-STD-202 Method 107, Condition B, MIL-STD-202 Method 106, MIL-STD-202 Force to Engage — Force to Disengage — Center Contact Retention — Durablilty — Radial Misalignment — Rigid Mount Float Mount 3 pounds max. 1.5 pounds max. 4 pounds min. 1,000 Cycles ±.06 [±.0025] ±.51 [±.020] Mating Characteristics Jack Connector — Center Contact Socket Oversize test Pin — Test Pin Finish — Insertion Depth — Number of Insertions — Insertion Force Test Pin — Test Pin Finish — Insertion Force — Withdrawal Force Test Pin — Test Pin Finish — Insertion Depth — Withdrawal — .533 + .003 [.0210 + .0001] dia. 16 micro inch max. .76/1.14 [.030/.045] 3 .528 + .003 [.0208 + .0001] dia. 16 micro inch 3 pounds max. .495 + .003 [.0195 - .0001] dia. 16 micro inch max. 1.27/1.91 [.050/.075] 1/2 ounce min. Finish Center Contact — Housing — Gold plate per MIL-G-45204, Type II, Class 0 over nickel plate per QQ-N-290, Class 2 or passivate per ASTM-A380 Gold plate per MIL-G-45204, Type II, Class 0 over nickel plate per QQ-N-290, Class 2 or passivate per ASTM-A380 Material Housing — Center Contact — Dielectric — Gasket (O’Ring) — 172 Corrosion resistant steel Type 303 (stainless) per ASTM A484 and A582 Beryllium copper per ASTM-B-196 TFE fluorocarbon per ASTM-D-1457 MIL-P-25732 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSSP Subminiature Modular Blind Mate Connectors Interface Mating Dimensions The connector interface, specifically designed for multiple interconnects, maintains reliable performance over the typical mechanical tolerance required in cost effective packaging. Jack The interface test data shows excellent performance is maintained with mating gaps up to .015 inch. Description Jack Plug A 1.22 Nom. 0.48 1.22 Nom. 0.48 Plug B 3.91 Min. .154 3.56 .140 Nom. Dimensions C D 5.33 Ref. 5.00 Nom.* .210 .197 5.33 Ref. 5.00 .210 .199 Min. E 3.35 Max. .132 0.51 .020 Nom. F 3.23 Max.* .127 3.25 .128 Min. *With spring bottomed. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 173 Catalog 1307191 Revised 10-00 RF Coax Connectors OSSP Subminiature Modular Blind Mate Connectors (Continued) For Semi-Rigid Cable, 2.16 [.085] Dia., Direct Solder Attachment Bulkhead Feedthrough Cable Plug — Rear Mount 2.3 Dia. Min. [.089] 4.6 ± 0.03 Dia. [.180 ± .001] 3.0 Dia. [.120] 17.5 [.690] ed e [. 7.3 Max. [.289] 0.03 4.6 +– .000 Dia. .001 ] [ .182 +– .000 Recommended Mounting Hole Cable Plating M/A-COM Model No. Part No. RG-405/U, 2.16 [.085] Gold 4703-7985-00 1255511-1 Flange Mount Cable Jack — Floating Rear Mount 0.08 7.1 +– 0.00 Dia. + .003 [.281 – .000 ] 2.4 Dia. [.093] 2 Plcs. 3.0 Dia. [.120] 14.7 Dia. [.580] 11.0 ± 0.10 [.435 ± .004] 0.08 7.1 +– 0.00 Dia. + .003 [.281 – .000 ] 11.0 [.435] 0.00 7.1 +– 0.05 Dia. + .000 [.280 – .002 ] 18.0 [.710] 2.3 [.089] Dia. ded Hole 5.5 [.217] 7.6 [.300] 0.00 7.1 +– 0.05 Dia. + .000 [.280 – .002 ] Recommended Mounting Hole Cable M/A-COM Model No. Part No. RG-405/U, 2.16 [.085] 4706-7985-02 1059868-1 Finish: Inner housing that is soldered to cable is gold plated. Outer housing is passivated stainless steel. When using semi-rigid cable, it is recommended that a service loop be used to facilitate the float features of the connector. 174 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSSP Subminiature Modular Blind Mate Connectors (Continued) For Flexible Cable, Crimp Attachment Bulkhead Feedthrough Cable Plug — Rear Mount 4.6 ± 0.03 Dia. [.180 ± .001] [. 0.03 4.6 +– .000 Dia. + .001 [.182 – .000 ] 33.0 Ref. [1.298] d e Flange Mount Cable Jack — Floating Rear Mount Recommended Mounting Hole Cable Plating M/A-COM Model No. Part No. RG-188/U, 316 Double Braided Only Passivated Stainless Steel 4733-7316-02 1059884-1 2.4 Dia. [.093] 2 Plcs. 0.08 .1 +– 0.00 Dia. + .003 81 – .000 ] 14.7 Dia. [.580] 0.08 7.1 +– 0.00 Dia. + .003 [.281 – .000 ] 11.0 ± 0.10 [.435 ± .004] 11.0 [.435] 0.00 7.1 +– 0.05 Dia. + .000 [.280 – .002 ] 35.6 [1.40] Max. 0.00 7.1 +– 0.05 D 5.5 [.217] 7.6 [.300] + .000 [.280 – .002 ] Recommended Mounting Hole Cable Plating M/A-COM Model No. Part No. RG-188/U, 316 Double Braided Only Passivated Stainless Steel 4736-7316-02 1059888-1 For Panel Mount Straight Terminal Threaded Installation — Panel Feedthrough Plug Receptacle 0.4 Dia. [.015] 11.4 [.450] 4.0 Dia. [.156] 1.2 Dia. [.049] 4.1 ± 0.03 Dia. [.162 ± .001] 5.3 ± 0.05 [.210 ± .002] 1.3 ± 0.03 Dia. [.051 ± .001] 6.4 [.250] Recommended Mounting Hole Plating Passivated Stainless Steel Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] M/A-COM Model No. 4757-5006-02 Part No. 1059903-1 www.amp.com/communications/com Specifications subject to change. 175 Catalog 1307191 Revised 10-00 RF Coax Connectors OSSP Subminiature Modular Blind Mate Connectors Hermetically Sealed Metal to Metal Formable Gasket — Panel Feedthrough Plug Receptacle 3.6 Dia. [.140] 1.0 Dia. [.039] 12.1 [.475] VSWR (GHz) 1.06 + .01f RF Leakage (dB) –(85-fGHz) 3.0 Dia. [.118] .03 Dia. [.012] Plating Gold M/A-COM Model No. 4757-5014-00 Part No. 1059905-1 M/A-COM Model No. 4757-3204-00 Part No. 1059902-1 Recommended Mounting Hole Detail A at bottom of this page. 0.00 4.8 +– 0.05 Dia. Solder and Braze-In Panel Feedthrough Plug Receptacle 5.3 Dia. [.210] + .000 [.189 – .002 ] 8.2 [.322] Ref. VSWR (GHz) 1.06 + .01f RF Leakage (dB) –(85-fGHz) 0.5 ± 0.03 Dia. [.020 ± .001] Plating Gold Recommended Mounting Hole Details at bottom of this page. Field Replaceable Solder and Braze-In 2-Hole Flange Mount Plug Receptacle With EMI/RFI Gasket 1.9 + 0.05 – 0.03 [.076 + .002] – .001 5.3 Dia. [.210] 2.4 Dia. [.093] 2 Plcs. Dia. 12.2 Dia. [.480] 9.0 [.353] 9.5 [.375] VSWR (GHz) 1.06 + .01f 8.2 ± 0.13 [.322 ± .005] RF Leakage (dB) –(85-fGHz) 0.3 ± 0.03 [.012 ± .001] Dia. 5.7 [.223] Plating Passivated Stainless Steel M/A-COM Model No. 4751-3355-02 Part No. 1059894-1 Recommended Mounting Hole Detail B at bottom of this page. Recommended Mounting Hole Detail for Hermetically Sealed Detail A* Detail B* 3.2 ± 0.13 [.125 ± .005] Panel .000 1.0 +– 0.03 + .000 Dia. Dia. .001 [.041 – .001 ] ] [.162 +– .002 .003 4.1 +– 0.05 6.4 [.250] Ref. 2.0 ± 0.03 [.078 ± .001] Dia. 3.2 ± 0.03 [.121 ± .001] Dia. 9.0 [.353] Ref. *Consult appropriate Instruction Sheet for complete mounting procedure. 176 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors Product Facts ■ SMB offers snap-fit coupling for quick connect/disconnect ■ Choice of Commercial or High Rel Connectors ■ 50 and 75 Ω MIL-Type connectors available ■ Straight plugs and jacks are completely crimp terminated ■ Fast easy cable assembly ■ Low VSWR ■ Standard military, commercial or AMP tooling ■ Listed under the Component Program of Underwriters Laboratories Inc., File No. E81956 ■ PC Board soldered connectors are recognized under the Component Program of Underwriters Laboratories Inc., File No. E81956 R R ■ Certified by Canadian Standards Association File No. LR 7189 R SMB Connectors are available in commercial and high rel versions. They are ideally suited for circuit miniaturization and are offered in a wide range of configurations including plugs, right angle plugs, jacks, bulkhead jacks and adapters, as well as printed circuit board and solder jacks. Termination costs are kept to a minimum using plugs and jacks with a crimp center contact and hex crimp outer braid. Both hand held tooling and pneumatic bench-mounted tooling is available. Easily assembled right-angle plugs have a hex crimp on the outer braid ferrule and bifurcated solder center contacts. Tyco 75 Ohm BT 43 SMB Connectors feature unique spring mating with snap-fit couplings for quick connect/disconnect. These connectors are designed to be intermateable with 75 Ohm SMB MIL-C-39012 connectors. They also feature reliable dual crimp cable terminations. Packaging — All connectors are packaged individually unless otherwise noted under the “Military No. and/or Comments” column in the connector specifications chart. Between Series Adapters For SMB Between Series Adapters, please see Pages 255-264. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 177 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connector Specifications Electrical Characteristics Environmental Characteristics Impedance — 50 ohms and 75 ohms, nominal Frequency Range — 0 to 4.0 GHz Voltage Rating (VRMS) — Temperature Rating — -65°C to +165°C Corrosion (salt spray) — MIL-STD-202, Method 101, test condition B, 5% salt solution Vibration High Frequency — MIL-STD-202, Method 204, test condition B (15 G’s) Shock — MIL-STD-202, Method 213, test condition B, 75 G’s at 6 milliseconds, 1/2 sine Thermal Shock — MIL-STD-202, Method 107, test condition B, except high temperature shall be +85°C. High temperature shall be +200°C for connectors using 200°C cables. Moisture Resistance — MIL-STD-202, Method 106, when interface gasket is used. No measurements of high humidity. Insulation resistance shall be 200 megohms minimum within five minutes after removal from humidity. Durability Test — Conducted per MIL-C-39012 Reg. Para. 3.15, Method Para. 4.6.12 50 ohm connectors for RG-178/U series cable 50 ohm connectors for RG-316/U series cable 75 ohm connectors for RG-179/U series cable 75 ohm connectors for RG-195/U series cable Sea Level 300 400 300 500 70,000 Feet 75 100 75 125 Initial 6.0 1.0 1.0 After Environment 8.0 1.5 N/A Insulations Resistance — 1000 megohms min. Contact Resistance — (milliohms max.) Center contact Outer contact Braid to body Contact Current Rating — 1.5 amps DC max. Voltage Standing Wave Ratio (VSWR) — to 4.0 GHz or 80% of upper cutoff frequency of the cable, whichever is lower. Body, Body Components and Male Contacts — Brass, half hard, per QQ-B-626, Alloy 360, Zinc per QQ-Z-363 Female Contacts — Beryllium copper per QQ-C-530, heat treated per MIL-H-7199. Insulators — TFE fluorocarbon per ASTM D 1710, Type 1, Grade 1. Lockwashers — Phosphor bronze per QQ-B-750. Crimp Ferrule — Annealed copper alloy per WW-T-799. Gaskets — Silicone rubber per ZZ-R-765, Class 11B, Grade 65-75. Plating Mating Engagement Cable Materials Straight Rt. Angle RG-178/U Series 1.30 + .04F 1.45 + .06F RG-316/U Series 1.25 + .04F 1.35 + .04F Center Contacts — 0.00127 [.000050] min. Gold per MIL-G-452048 Type 1, Grade C, Class 1, over 0.00254 [.000100] min. nickel per QQ-N-290 Other Metal Parts — Gold, Nickel or Solder plated to meet the Finish and Corrosion requirements of MIL-C-39012. F=GHz, does not apply to 75 ohm connectors. RF High Potential Withstanding Voltage Frequency-5 MHZ Leakage Current-N/A 50 ohm connectors for RG-178/U series cable 50 ohm connectors for RG-316/U series cable 75 ohm connectors for RG-179/U series cable 75 ohm connectors for RG-195/U series cable 675 VRMS 950 VRMS 950 VRMS 1225 VRMS RF Leakage — -55 dB min. at 2-3 GHz Insertion Loss — .30dB max. at 3 GHz Mechanical Characteristics Engagement Forces — 14 lbs. [62.3 N] maximum engagement initially. After 500 matings, 14 lbs. [62.3 N] maximum engagement and 2 lbs. [8.8 N] minimum disengagement for all of SMBs. Cable Attachment — Straight Connectors–Crimp, both center contact and braid Right-Angle Connectors–Crimp on braid and bifurcated solder center contact. Durability — 500 cycles per MIL-C-39012 Contact Captivation — When captivated, the contacts will withstand 4.0 lbs. minimum axial force. Cable Retention — When properly assembled to the compatible braided coaxial cable, the retention is equal to the breaking strength of the cable. Marking — Per MIL-STD-130 178 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 50 Ohm Straight Plugs 6.35 [.250] Max. 21.10 [.830] Max. Center Contact Plating Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold RG/U Cable 178, 178A, 178B, 196, 196A 174, 316, 188, 188A 179, 179A, 179B, 161, 187, 187A, Belden 9221 RD 316, 188 Double Braid Right Angle Plugs Outer Contact Plating Gold Gold Gold Gold Nickel Gold Nickel Nickel Gold Gold Gold Nickel Gold Gold Gold Nickel Nickel Mil Type Other Metal Parts Plating Gold Nickel Gold Nickel Nickel Nickel Nickel Black Nickel Gold Nickel Nickel Nickel Gold Nickel Nickel Nickel Nickel Dielectric Style Part No. TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON Mil Type Mil Type Mil Type Mil Type Mil Type Die Cast Die Cast Die Cast Mil Type Mil Type Die Cast Die Cast Mil Type Mil Type Die Cast Mil Type Die Cast 2-413985-5 2-413985-6 2-413985-1 2-413985-3 2-413985-7 2-414946-1 2-414946-2 1-414946-2 1-413985-0 1-413985-1 1-414946-5 1-414946-6 2-413985-2 2-413985-4 2-414946-3 2-413985-8 2-414946-4 Die Cast 13.71 Max. [.540] 13.71 [.540] Max. 6.35 Dia. [.250] 6.35 [.250] Dia. 13.21 [.520] Max. RG/U Cable 178, 178A, 178B, 196, 196A 174, 316, 188, 188A 179, 179A, 179B 161, 187, 187A Belden 9221 RD 316, 188 Double Braid Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 13.21 [.520] Max. Center Contact Plating Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Gold Dimensions are in millimeters over [inches] Outer Contact Plating Gold Gold Gold Nickel Gold Gold Nickel Gold Nickel Gold Gold Gold Nickel Other Metal Parts Plating Gold Nickel Nickel Nickel Gold Nickel Nickel Nickel Nickel Gold Nickel Nickel Nickel Dielectric Style Part No. TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON Mil Type Mil Type Die Cast Die Cast Mil Type Mil Type Mil Type Die Cast Die Cast Mil Type Mil Type Die Cast Die Cast 414002-7 414002-8 414363-8 414363-9 414002-1 414002-3 414002-5 414363-3 414363-5 414002-2 414002-4 414363-4 414363-6 www.amp.com/communications/com Specifications subject to change. 179 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 50 Ohm (Continued) Straight Jacks Commercial Jack Mil Type Jack 5.56 Hex. [.219] 25.40 [1.000] RG/U Cable 178, 178A, 178B, 196, 196A 174, 316, 188, 188A RD 316, 188 Double Braid 179, 187 Center Contact Plating Gold Gold Gold Gold Gold Gold Body Plating Dielectric Style Jack Part No. Nickel Nickel Nickel Nickel Nickel Nickel TEFLON TEFLON TEFLON TEFLON TEFLON TEFLON Mil Type Mil Type Commercial Die Cast Commercial Die Cast 414170-2 414170-1 414948-1 1274035-1 414948-3 414948-2 Bulkhead Jack Bulkhead Jacks 6.35 [.250 ] Hex. 28.60 [1.120] RG/U Cable 178, 178A, 178B, 196, 196A 174, 316, 188,188A RD 316, 188 Double Braid Center Contact Plating Gold Body Plating Dielectric Style Bulkhead Jack. Part No. 415006-3 Nickel TEFLON Commercial Gold Nickel TEFLON Commercial 415006-1 Gold Nickel TEFLON Commercial 415006-2 Bulkhead Jack Adapter 5/4.88 Dia. [.197/.192] (Jack-Jack) 6.35 [.250] Hex. 17.53 Max. [.690] 2.08/2.01 [.082/.079] Maximum Panel Thickness 2.36 [.093] Recommended Panel Cutout for Bulkhead Jack and Adapter Type Jack-To-Jack 180 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Center Contact Plating Gold Gold Dimensions are in millimeters over [inches] Body Plating Dielectric Style Part No. Nickel Gold TEFLON TEFLON Mil Type Mil Type 228553-1 228553-2 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 50 Ohm (Continued) PC Board Jacks and Plugs, Vertical Commercial Mil Type Die Cast A A Max. B A B B Max. 5.08 [.200] Ø 1.60 [.063] 4 Plcs. 2.54 [.100] 5.08 [.200] Ø 1.19 [.047] Recommended PC Board Layout Jacks Type Center Contact Plating Body Plating Dim. A Dim. B Dielectric Style Part No. –– Gold Gold Mil Type 413990-1 Gold Nickel TEFLON Mil Type 413990-2 –– Gold Nickel TEFLON Die Cast 415590-1 –– Gold Nickel TEFLON Mil Type 414612-2 Low Profile (Jack) Mated Pair Gold Gold 3.94 .155 3.94 .155 3.94 .155 2.54 .100 5.84 .230 TEFLON –– 7.62 .300 7.62 .300 7.62 .300 10.16 .400 3.94 .155 TEFLON Mil Type 415773-1 11.53 ± 0.20 [.454 ± .008] 6.35 [.250] Sq. 3.94 ± 0.13 [.155 ± .005] 0.64 [.025] 6.32 [.249] 5.08 ± 0.05 [.200 ± .002] 1.02 ± 0.05 Typ. [.040 ± .002] Ø 6.35 [.250] Ø 0.97 ± 0.03 [.038 ± .001] Ø 1.60 4 Plcs. [.063] 2.54 [.100] 5.08 [.200] Ø 1.19 [.047] Recommended PC Board Layout 1.42 Typ. [.056] Plugs Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Type Center Contact Plating Body Plating Dim. A Dim. B Dielectric Recommended PC Board Layout Style Part No. Low Profile (Plug) Mated Pair Gold Nickel 3.94 .155 7.62 300 TEFLON B Mil Type 415774-1 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 181 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 50 Ohm (Continued) PC Board Jacks and Plugs, Right Angle Jack Low Profile Jack with Standoff Pads 12.70 [.500] 13.46 [.530] A Bulkhead Jack A 19.87 [.782] A B B B Jacks Type Center Contact Plating Interface Body Plating PCB Leg Plating Dielectric Dim. A Dim. B Style Recommended PC Board Layout Part No. Gold Gold Gold TEFLON B 413996-2 Nickel Nickel TEFLON Mil Type B 413996-4 Gold Gold Gold TEFLON Die Cast B 415340-1 Gold Gold Gold TEFLON Die Cast B 415672-1 Gold Gold Gold TEFLON Mil Type B 414026-2 Gold Nickel Nickel TEFLON Mil Type B 414026-3 Gold Gold Nickel TEFLON Mil Type B 414026-4 Gold Nickel Tin-Lead TEFLON Die Cast B 414337-1 Gold Nickel Nickel TEFLON Die Cast C 414379-1* Gold Nickel Nickel TEFLON Die Cast B 415381-1 Gold Gold Gold TEFLON 3.94 .155 3.94 .155 2.79 .110 2.79 .110 3.94 .155 3.94 .155 3.94 .155 3.94 .155 2.79 .110 3.94 .155 2.79 .110 Mil Type Gold 7.11 .280 7.11 .280 7.11 .280 8.76 .345 8.51 .335 8.76 .345 8.51 .335 8.76 .345 8.76 .345 8.51 .335 7.67 .302 Die Cast B 414963-1 Low Profile With Standoff Pads Bulkhead * 5 leg design 5.08 [.200] 13.46 [.530] A Ø 1.75 [.069] 4 Plcs. 2.54 [.100] 1.70 Dia. [.067] Min. (4 Holes) 5.08 [.200] 6.35 Dia. [.250] 1.19 Dia. [.047] Min. B 5.08 [.200] 2.54 [.100] 5.08 [.200] Ø 1.24 ± 0.05 [.049 ± .002] B A Recommended PC Board Layouts Plugs Center Contact Plating Interface Body Plating PCB Leg Planting Dielectric Dim. A Dim. B Style Recommended PC Board Layout Part No. Gold Gold Nickel TEFLON A 415382-1* Nickel Nickel TEFLON 3.94 .155 2.79 .110 Die Cast Gold 8.76 .345 8.76 .345 Die Cast B 415380-1* * 5 leg design 182 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 50 Ohm (Continued) Bulkhead PCB Jack, Solder Receptacle Kits 5/4.88 [.197/.192] Dia. 6.35 Hex. [.250] 2.08/2.01 [.082/.079] 16.0 Max. [.630] Kit Includes Lockwasher and Jam Nut Type Front Mount Rear Mount Lockwasher and Jam Nut Center Contact Plating Gold Gold Maximum Panel Thickness 2.36 [.093] Recommended Panel Cutout Body Plating Dielectric Style Nickel Nickel TEFLON TEFLON Mil Type Mil Type Kit Part No. 228216-1* 228215-1* *includes Jam Nut and Lockwasher Part No. 415001-2 Part No. 414969-2 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 183 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, Mini 75 Ohm Product Facts ■ Industry standard for miniature 75 ohm SMB ■ SMB offers snap-fit coupling for quick connect/disconnect ■ Suitable for high density applications ■ Fast easy cable assembly ■ Low VSWR ■ Connectors offer consistent mating and unmating forces ■ Straight plugs and jacks are completely crimp terminated ■ Low cost Mini 75 ohm SMB connectors are ideally suited for circuit miniaturization in communication, broadband and switching equipment as well as a variety of other applications. They offer the same low consistent mating/unmating force as AMP standard SMB products and therefore, outer contact resistance values are maintained from connector to connector. Standard military, commercial or AMP tooling can be used to terminate these products. Cost effective assembly of the straight plugs is completed with a crimp center contact and hex crimp on the outer braid. Right angle plugs have a hex crimp on the outer braid ferrule and bifurcated solder center contacts. Electrical Characteristics Impedance — 75 ohms Frequency Range — 0 to 4.0 GHz Insulation Resistance — 1000 megohms Contact Current Rating — 1.5 amps DC max. Mechanical Characteristics Engagement Forces — Initial — 14.0 lbs. [62.3 N] maximum engagement. After 500 matings, 14.0 lbs. [62.3 N] maximum engagement. Durability — 500 cycles Environmental Characteristics Temperature Rating — -65°C to +165°C 184 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, Mini 75 Ohm (Continued) Straight Plug Ø 1.73 [.068] Ø 6.35 [.250] Ø 2.64 [.104] 17.78 Ref. [.700] Center Contact Plating Gold Gold Gold RG Cable 179, 187 179, 187 RD 179 Right Angle Plug Outer Contact Plating Gold Nickel Nickel Body Plating Nickel Nickel Nickel Part No. 415487-1 415487-2 415487-3 13.7 Max. [.539] 10.21 Ref. [.402] Ø 6.35 [.250] 9.78 ± 0.25 [.385 ± .010] Center Contact Plating Gold Gold Gold RG Cable 179, 187 179, 187 RD 179 Bulkhead Jack Outer Contact Plating Nickel Gold Gold 16.0 Ref. [.630] Body Plating Nickel Nickel Nickel Part No. 415484-1 415484-2 415484-3 22.86 Max. [.900] Ø 3.66 ± 0.05 [.144 ± .002] Ø 5.03 [.198] 4.52 [.178] 9.7 [0.38] Recommended PC Board Layout 10.92 [.430] 6.35 Hex. [.250] RG Cable 179, 187 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Center Contact Plating Gold Body Plating Nickel Part No. 415500-1 www.amp.com/communications/com Specifications subject to change. 185 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, Mini 75 Ohm (Continued) Vertical PC Board Jacks 5.08 ± 0.08 [.200 ± .003] 7.62 ± 0.18 [.300 ± .007] Ø 0.71 ± 0.08 [.028 ± .003] Ø 3.67 Max. [.145] Ø 1.32 ± 0.08 [.052 ± .003] 4 Plcs. Leg Length 2.11 .083 2.11 .083 3.05 .120 3.05 .120 Right Angle PC Board Jacks 2.54 ± 0.08 [.100 ± .003] 3.18 [.125] 5.08 ± 0.08 [.200 ± .003] Recommended PC Board Layout Center Contact Plating Body Plating Part No. Gold Gold 415504-1 Gold Gold Flash 415504-2 Gold Gold 415504-3 Gold Gold Flash 415504-4 5.54 [.218] 5.08 ± 0.08 [.200 ± .003] 7.95 ± 0.25 [.313 ± .010] 2.54 ± 0.08 [.100 ± .003] Ø 0.71 ± 0.08 [.028 ± .003] 5.08 ± 0.08 [.200 ± .003] 14.1 [.555] Ø 1.32 ± 0.08 [.052 ± .003] 4 Plcs. Recommended PC Board Layout Ø 3.71 Max. [.146] Leg Length 2.79 .110 2.79 .110 2.11 .083 2.11 .083 Right Angle PC Board Bulkhead Jacks Center Contact Plating Body Plating Part No. Gold Gold 415490-1 Gold Nickel 415490-2 Gold Gold 415490-3 Gold Nickel 415490-4 2.79 [.110] 4.50 [.177] 5.08 ± 0.08 [.200 ± .003] 2.54 ± 0.08 [.100 ± .003] Ø 0.71 ± 0.08 [.028 ± .003] 19.94 [.785] 2.36 Max. [.093] Panel Thickness 11.18 [.440] 5.08 ± 0.08 [.200 ± .003] Ø 1.32 ± 0.08 [.052 ± .003] 4 Plcs. Recommended PC Board Layout Ø 3.71 Max. [.146] Leg Length 2.79 .110 2.79 .110 186 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Center Contact Plating Body Plating Part No. Gold Nickel 415377-1 Gold Gold 415377-2 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 75 Ohm Straight Plugs 11.59 [.456] RG/U Cable Center Contact Plating 179, 179A, 179B, 161, 187, 187A, Belden 9221 Center Contact Plating Gold Gold Gold Gold 21.10 [.830] Outer Body Plating Outer Contact Plating Dielectric Style Gold Gold Nickel TEFLON Mil Type 414618-1 Gold Nickel Nickel TEFLON Mil Type 414618-2 Outer Body Plating Gold Gold Nickel Nickel Outer Contact Plating Nickel Nickel Nickel Nickel Dielectric Style Part No. TEFLON TEFLON TEFLON TEFLON Mil Type Commercial Mil Type Commercial 414048-6 415462-1* 1-414048-3 415462-2* Part No. 9.14 Dia. [.360] Right Angle Plugs 16.26 [.640] RG/U Cable 19.05 [.750] 179, 179A, 179B, 161, 187, 187A, Belden 9221 +0.13 Straight Jacks 8.00 -0.00 Dia. [.315 +.005 ] -.000 8.74 Hex. [.344] +0.08 27.69 [1.090] 3.43 -0.00 [.135 +.003 ] -.000 Maximum Panel Thickness 2.36 [.093] Recommended Panel Cutout RG/U Cable Center Contact Plating Body Plating Dielectric Style Part No. 179, 179A, 179B, 161, 187, 187A, Belden 9221 Gold Nickel TEFLON Mil Type 414767-1 30.99 ± 0.25 [1.22 ± 0.01] Blukhead Jacks 7.54 ± 0.08 [.297 ± .003] 12.07 [.475] 8.38 ± 0.08 Dia. [.330 ± .003] 9.54 [.375] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Recommended Panel Cutout RG/U Cable Center Contact Plating Body Plating Dielectric Style Part No. 179, 179A, 179B, 161, 187, 187A, Belden 9221 Gold Front-Gold Rear-Nickel Nickel TEFLON Mil Type 414075-2 TEFLON Mil Type 414075-6 Gold Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 187 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 75 Ohm (Continued) PC Board Jacks Vertical Right Angle 16.77 [.660] 9.78 [.385] 5.08 [.200] 2.54 [.100] 6.15 .242 [.242] 6.15] 7.62 .300 [.300] [7.62] 5.08 [.200] 1.32 Dia. [.052] (5 Holes) 3.94 [.155] Recommended PC Board Layout Type Vertical Center Contact Plating Gold Gold Right Angle Gold Body Plating Dielectric Style Part No. Gold Tin-Lead Front-Nickel Rear-Tin-Lead TEFLON TEFLON Mil Type Mil Type 414244-1 414244-4 TEFLON Commercial 221014-1 Plating: 0.00076 [.000030] thick Bulkhead PCB Jack Kit .271 6.88 [6.88] [.271] 16.13 .635 [.635] [16.13] ± .020 .220±.051 5.59 ± 0.51 [5.59±.020 [.220 ]] Kit includes Lockwasher and Jam Nut 14.50 .571 [.571] [14.50] Max. Max. 3.43 .135 [.135] [3.43] ±0.08 1.02±.003 .040 Dia. ±.003] ] [.040±0.08 [1.02 HolesPlated PlatedTThru Holes .271 6.88 [6.88] 3.43 [.271] .135 [.135] [3.43] +.008 +.003 .059-.010 1.50 -.004Dia. +.003 +0.08 [.059 ] Dia. 1.50-.004 -0.10 Lockwasher and Jam Nut 4 Plcs. Holes Plated Thru Recommended PC Board Layout Type Part No. 221486-2 188 Part No. 221461-2 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Press Fit Center Contact Plating Gold Dimensions are in millimeters over [inches] Body Plating Dielectric Nickel TEFLON www.amp.com/communications/com Kit Part No. 415577-2 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 75 Ohm BT 43 Features ■ Widely used in data transmission and telecommunication applications ■ BT 43 connector developed from the SMB range and feature snap-on and latching variant ■ Most BT 43 connectors are available as fully crimped connectors. ■ BT 43 and 75 Ω connectors available in solder and crimp versions The AMP range of 75 ohm SMB (SMZ) connectors are designed to meet the increasing demands of the Telecommunications market, and are designed in accordance with BS9210 F0022. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Specifications Max working voltage (dc) — 500 V Max proof voltage (dc) — 1.5 kV Contact resistance (inner) — 5 milliohm Contact resistance (outer) — 1 milliohm Bodies and other parts — Brass Female center contacts — Copper Alloy Male center contacts — Copper Alloy Outer contacts — BeCu Plating — Contacts and critical surfaces — Gold Other parts — Nickel Insulators — P.T.F.E. www.amp.com/communications/com Specifications subject to change. 189 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 75 Ohm BT 43 (Continued) Straight Socket, Snap-On 30.5 Assembled [1.20] 28.0 [1.10] 8.8 Dia. [0.35] Cable Type RG179B/U RG179B/U BT3002, TZC75024 BT2002 20.4 [0.80] Termination Method Inner Outer Solder Crimp Crimp Crimp Crimp Crimp Crimp Crimp Straight Socket, Latching, Crimp/Crimp Body Plating M/A-COM Model No. Part No. Selective Gold Selective Gold Selective Gold Selective Gold B67A53T022X B67A54T022X B67A54T437X B67A54T117X 1408053-1 1311097-1 1361579-1 1311098-1 29.9 Assembly [1.18] 27.8 [1.09] Selective Gold Selective Gold Selective Gold Selective Gold Selective Gold M/A-COM Model No. B67A64T022X B67A64T062X B67A64T117X B67A64T280X B67A64T437X 1311099-1 1311100-1 1311101-1 1311696-1 1311102-1 Selective Gold B67A64TA25X 1313507-1 Cable Type Body Plating RG179B/U BT2003 BT2002 BT2001 BT3002, TZC75024 RG59B/U, RG140/U, URM90 Straight Socket, Latching, Solder/Crimp 9.6 Dia. [0.38] 29.9 Assembly [1.18] 27.8 [1.09] 190 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. Cable Type Body Plating RG179B/U BT2003 BT2002 Selective Gold Selective Gold Selective Gold Dimensions are in millimeters over [inches] 9.6 Dia. [0.38] M/A-COM Model No. B67A44T022X B67A44T062X B67A44T117X Part No. 1312112-1 1314669-1 1311213-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 75 Ohm BT 43 (Continued) Right Angle Socket, Snap-On, Solder/Crimp 17.93 Max. [0.71] 21.67 Max. [0.85] 16.86 [0.66] 10.16 Max. Max. [0.40] Cable Type Body Plating RG179B/U BT3002, TZC75024 BT2002 Selective Gold Selective Gold Selective Gold Right Angle Socket, Latching, Solder/Crimp M/A-COM Model No. B67B42T022X B67B42T437X B67B42T117X Part No. 1311103-1 1311104-1 1314675-1 23.0 Ref. [0.91] 21.0 Ref. [0.83] 16.3 Ref. [0.64] 9.9 Ref. [0.39] Selective Gold Selective Gold Selective Gold Selective Gold M/A-COM Model No. B67B44T022X B67B44T062X B67B44T117X B67B44T437X 1311106-1 1311698-1 1311108-1 1311111-1 Selective Gold B67B44T693X 1328162-1 Selective Gold B67B44TA25X 1313508-1 Cable Type Body Plating RG179B/U BT2003 BT2002 BT3002, TZC75024 3M: 043, 031C, CS4456, Gore: GCX RG59B/U, RG140/U Straight Free Plug, Crimp/Crimp Part No. 30.4 Assembled [1.20] 20.2 [0.80] 8.82 Dia. [0.35] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 5.60 [0.22] Cable Type Body Plating RG179B/U Selective Gold Dimensions are in millimeters over [inches] M/A-COM Model No. B67E64T022X Part No. 1408041-1 www.amp.com/communications/com Specifications subject to change. 191 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 75 Ohm BT 43 (Continued) 30.8 Assembled [1.21] Straight Bulkhead Plug 28.5 [1.12] 10.8 [0.43] 3.0 Max [0.12] Panel 8.4 [0.33] Dia. 5.6 [0.22] 7.5 [0.30] Mounting Detail Cable Type RG179B/U BT2002 RG179B/U BT500B, BT2003, BT2003A BT2002 BT3002, TZC75024 Termination Method Inner Outer Solder Crimp Solder Crimp Crimp Crimp Body Plating M/A-COM Model No. Part No. Selective Gold Selective Gold Selective Gold B67H46T022X B67H46T117X B67H66T022X 1312370-1 1311114-1 1311120-1 Crimp Crimp Selective Gold B67H66T062X 1311701-1 Crimp Crimp Crimp Crimp Selective Gold Selective Gold B67H66T117X B67H66T437X 1311121-1 1311122-1 32.1 Assembled Length [1.26] 10.75 ± 0.05 [0.42 ± .002] 9.50 ± 0.10 [0.37 ± .004] 7.50 A/F [0.30] Panel Cut Out Cable Type 3M: 043, 031C, CS4456, Gore: GCX 8.00 Dia. [0.31] Termination Method Inner Outer Body Plating M/A-COM Model No. Part No. Crimp Selective Gold B67H16T493X 1313511-1 Crimp Right Angle Bulkhead Plug, Solder/Crimp 192 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Cable Type Body Plating RG179B/U BT2002 Selective Gold Selective Gold Dimensions are in millimeters over [inches] M/A-COM Model No. B67H49T022X B67H49T117XP2 Part No. 1311115-1 1314694-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 75 Ohm BT 43 (Continued) DDF Plug, Crimp/Crimp 30.4 Assembled [1.20] 27.9 [1.10] 10.3 Dia. [0.41] Selective Gold Selective Gold Selective Gold Selective Gold Selective Gold M/A-COM Model No. B67H64T022X B67H64T062X B67H64T117X B67H64T280X B67H64T437X 1327083-1 1311117-1 1311700-1 1313883-1 1311118-1 Selective Gold B67H64TA25X 1313887-1 Cable Type Body Plating RG179B/U BT2003 BT2002 B2001 BT3002, TZC75024 RG59B/U, RG140/U, URM90 Part No. DDF Plug, Crimp/Crimp 32.1 Typ. [1.26] Assembled Length 32.1 Typ. [1.26] Assembled Length 15.67 ± 0.04 [0.62 ± .002] 9.50 ± 0.10 [0.37 ± .004] 13.76 ± 0.04 [0.54 ± .002] 9.50 ± 0.10 [0.37 ± .004] 5.32 Max. Panel [0.21] 5.10 Max. Panel [0.20] Part No. 1313512-1 Part No. 1311699-1 7.54 Ref. [0.30] 27.8 Ref. [1.09] Part No. 1314422-1 Cable Type Body Plating 3M: 043, 031C, Selective Gold CS4456, Gore: GCX 3M: 043, 031C, Selective Gold CS4456, Gore: GCX RD179, 124431 (Filotex), 1366 (Orebro), Selective Gold K02253D-1, K02253-2 (Shuner) Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] M/A-COM Model No. Part No. B67H14T493 1313512-1 B67H15T493 1311699-1 B67H74T463X 1314422-1 www.amp.com/communications/com Specifications subject to change. 193 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 75 Ohm BT 43 (Continued) Right Angle PCB Socket, Bulkhead Mount 14.96 Nom. [0.59] 6.35 Nom. [0.25] 3.85 Nom. [0.15] 9.53 Sq. [0.38] 16.85 12.00 Max. [0.66] [0.47] M/A-COM Model No. B67N25T999X B67N10T999X Body Plating Selective Gold Selective Gold PCB Plug 43/1D Part No. 1314102-1 1311126-1 11.4 [0.45] 6.20 Dia. [0.24] 3.80 [0.15] 5.08 [0.20] 5.08 [0.20] 0.90 Dia. [0.04] 1.70 Dia. [0.07] 4 Holes 1.20 Dia. [0.05] 1 Hole Mounting Detail M/A-COM Model No. B67N08T999X Body Plating Selective Gold PCB Plug 43/1E Part No. 1311125-1 13.2 [0.52] 9.5 [0.37] 15.0 [0.59] 6.5 [0.26] Sq. 5.08 [0.20] 1.70 Dia. [0.067] 4 Holes 5.08 [0.20] 1.20 Dia. [0.047] 1 Hole Mounting Detail Body Plating Selective Gold 194 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] M/A-COM Model No. B67N12T999X Part No. 1314103-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connectors, 75 Ohm BT 43 (Continued) Straight Adapter Plug-Plug 17.1 [0.67] 17.0 [0.67] 7.5 [0.30] 11.0 Dia. [0.43] 8.7 A/F [0.34] 2.2 Max. [0.09] Panel Part No. 1313364-1 Body Plating Selective Gold Selective Gold BT 43 Socket Termination 75 ohm 8.0 Dia. [0.31] Mounting Detail Part No. 1311127-1 M/A-COM Model No. 1B67P34G999X 2B67R53G999X Part No. 1313364-1 1311127-1 30.3 [1.19] 8.8 Dia. [0.35] Body Plating Selective Plating Tester 430A M/A-COM Model No. B67Z41T999X Part No. 1311702-1 37.4 [1.47] 11.1 [0.44] Dia. Body Plating Selective Plating 8.8 Dia. [0.35] M/A-COM Model No. B67Z50T999X Extraction Tool 65A Part No. 1311703-1 100.0 [3.94] 10.0 Dia. [0.39] M/A-COM Model No. 127669-92 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Part No. 1311164-1 www.amp.com/communications/com Specifications subject to change. 195 Catalog 1307191 Revised 10-00 RF Coax Connectors SMB Connector Crimp Tooling 50 Ω/75 Ω RG/U Cable Commercial Connector Tooling Center Contact Crimp Tooling Braid Crimp Tooling MIL-CDies for Dies for MIL-C22520/2-01 AMP AMP 22520/5-01 Tool PRO-CRIMPER PRO-CRIMPER Tool Hand Tool Hand Tool Daniels* Hex Daniels* Position Number Positioner Number Position Crimp Die 178, 178A, 178B, 196, 58489-1 196A Double Braid — 178, 196 174, 316 58489-1 188, 188A Double Braid 174, 316, 58489-1 188 Double Braid 174, 316, 58489-1 188 179, 179A 179B, 161, 58489-1 187, 187A, Belden 9221 179, 179A 179B, 161, 58489-1 187, 187A, Belden 9221 180, 180A — 180B Mini SMB 75 ohm 179, 187 — 179, 187 — Mil Type Connector Tooling Center Contact Crimp Tooling Braid Crimp Tooling Dies for AMP Daniels* Daniels* Daniels Selector PRO-CRIMPER Hand Positioner Hand Position Hand Tool Tool Number Tool Number Position Hex Die Across Flats Female-K699 Male-K727 4 58489-1 A&B Y624 AFM8 Female-K699 Male-K727 4 58483-1 A HX4-1637 2.67 .105 — — — — — AFM8 4 58483-1 B HX4-1637 Female-K699 Male-K727 4 58489-1 A Y444 AFM8 Female-K699 Male-K727 Female-K699 Male-K727 4 58483-1 B HX4-1637 3.25 .128 3.25 .128 Female-K699 4 58489-1 C Y196 Location A AFM8 Female-K699 4 58483-1 C HX4-1637 3.84 .151 Male-K727 4 58489-1 C Y196 Location A AFM8 Solder — 58483-1 B HX4-1637 3.25 .128 Female-K699 4 58489-1 A Y444 AFM8 Female-K699 4 58483-1 B HX4-1637 3.25 .128 Male-K727 4 58489-1 A Y444 — Solder — 58483-1 B HX4-1637 3.25 .128 — — — — — — Solder — 58483-1 C HX4-1637 3.84 .151 Female-K699 Solder Center Contact — 58483-1 B HX4-1637 — — — — — — — — 58483-1 B HX4-1637 — — — — — — — Note: All 75 ohm SMB connectors have a solder center contact. * Daniels Manufacturing Corporation 6103 Anno Avenue Orlando, Florida 32809 Telephone: 407-855-6161 FAX: 407-855-6884 Note: Equivalent military tool part numbers– M22520/5-01 – Daniels Hand Tool HX4 M22520/5-33 – Daniels Die Set Y136 M22520/5-37 – Daniels Die Set Y138 M22520/5-41 – Daniels Die Set Y140 M22520/5-03 – Daniels Die Set Y196 M22520/2-01 – Daniels Hand Tool AFM8 BT 43 Fixed Die Crimp Tool 203.0 [7.99] M/A-COM Model No. 30050 196 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Part No. 1331705-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors MCX Connectors Features ■ Snap-on interface facilitates assembly ■ Conforms to CECC interface specifications for MCX ■ 30% smaller than SMB connectors ■ Surface mount tape and reel for high volume Between Series Adapters For MCX Between Series Adapters, see Pages 255-264. AMP MCX microminiature snap-on connectors offer an excellent blend of size, durability and performance for emerging applications in GPS, automotive and wireless communications. MCX connectors are 30% smaller than traditional snap-on SMB connectors, offering greater packaging density and weight reduction. MCX connectors are mechanically robust with beryllium copper spring fingers rated at a minimum of 500 mating cycles. The snap-on interface facilitates assembly, eliminating the need for a threaded connection, and Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] ensuring full engagement. The forces to engage and disengage have been optimized to ensure ease of mating as well as to prevent damage to PCB solder connections. MCX connectors are designed for broad band performance, DC-6 GHz, and can be utilized for future system upgrades without concerns for performance degradation. AMP MCX connectors are fully mateable with standard MCX connectors and conform to the CECC interface specifications. MCX connectors are available in a broad range of standard configurations for commercial applications. Tape and reel packaging for MCX surface mount straight and right angle PCB receptacles is available to facilitate high volume pick and place manufacturing. MCX surface mount connectors are designed to withstand infrared reflow, convection and vapor phase soldering and provide a .254 [.010] standoff for optimal board cleaning. MCX plug and jack PCB receptacles also offer a direct board to board solution providing a nominal 7.11 [0.28] separation. www.amp.com/communications/com Specifications subject to change. 197 Catalog 1307191 Revised 10-00 RF Coax Connectors MCX Connectors (Continued) Specifications General CECC 22220 PARA Materials — Finish — — — Brass alloys UNS C36000 (ASTM-B16) or C38500 per QQ-B626, Beryllium copper per ASTM B-196, PTFE fluorocarbon per ASTM-D-1457 Center Contacts: Gold plated (MIL-G-45204) over nickel plate (QQ-N-290) Outer Contacts: Gold plated (MIL-G-45204) over nickel plate (OO-N-290) Housings: Nickel plated (QQ-N-290), tin lead (MIL-P-81728) or Gold plated (MIL-G-45204) All other metal parts shall be furnished so as to provide a connector which meets corrosion requirements of CECC 22220 PARA 4.6.10 The design shall be such that the outline and interface dimensions shown in this catalog and the requirements of CECC 22220 PARA are met — Design — Electrical CECC 22220 PARA (General requirements performance may vary by cable) Frequency Nominal Impedance Voltage Rating VSWR Insulation Resistance Insertion Loss Dielectric Withstanding Voltage Contact Resistance Center Contact Outer Contact Corona 70,000 ft. RF High Potential @ Sea Level Contact Current Mechanical — — — 4.4.1 — 4.4.4 — 4.4.5 dc - 6 GHz 50 ohms 335 Volts (VRMS Maximum) @ Sea Level 1.25:1 Maximum @ 4 GHz 1.35:1 Maximum @ 6 GHz 10,000 Megohms Minimum .1dB Maximum/1000 MHz 1000 Volts (VRMS Minimum) @ Sea Level 4.4.2 4.4.3 — — — 5.0 Milliohms Maximum 1.0 Milliohms Maximum 250 Volts (VRMS Minimum) @ MHz 670 Volts (VRMS Minimum) @ MHz 1.5 ADC Max CECC 22220 PARA Force to Engage Force to Disengage Contact Captivation Connector Durability Environmental 4.5.4 — 4.5.2 4.7.1 15.5 N [3.4 lbs.] Maximum 8 – 20 N [1.8 – 4.5 lbs.] Designed to maintain MCX interface when mating 10 N [2.2 lbs.] axial 500 insertion and withdrawal cycles CECC 22220 PARA Temperature Rating Vibration Moisture Resistance Corrosion Thermal Shock — 4.6.3 4.6.4 4.6.10 4.6.7 -65˚C + 165˚C MIL-STD-202, Method 204, Condition D MIL-STD-202, Method 106 MIL-STD-202, Method 101, Condition B, 48 Hours MIL-STD-202, Method 107, Condition C Meets or exceeds requirements of CECC 22220. AMP has design control and all data contained herein is subject to change without notice. Contact AMP for specifications on other connector types. F E N D B DIA. C DIA. J DIA. H DIA. I DIA. G A DIA. K L M Plug Letter A B C D E F G 198 Jack Minimum 0.48 [.0189] 2.00 [.0788] — 0.00 [.000] 2.80 [.111] 4.15 [.164] 2.80 [.111] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Maximum 0.53 [.0208] — 3.8 [.148] 0.30 [.0118] 3.20 [.125] — — Dimensions are in millimeters over [inches] Letter H I J K L M N Minimum — 3.42 [.135] 3.60 [.142] 2.30 [.091] 2.60 [.103] 4.00 [.158] 0.75 [.0296] Maximum 1.98 [.077] 3.48 [.137] 3.75 [.147] 2.80 [.110] 2.80 [.110] 4.12 [.162] 0.85 [.0334] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors MCX Connectors (Continued) Right Angle Cable Plug, Solder 5.00 [.197] Sq. 8.00 [.314] 3.50 [.137] 7.92 6.15 [.312] [.242] MCX Plug Cable RG-174/U, 188/U, 316/U Straight Cable Plug, Crimp Plating Gold M/A-COM Model No. 5807-5001-09 Part No. 1060788-1 16.3 Ref. [.642] MCX Plug 5.00 Dia. [.197] Cable RG-178/U, 196/U RG-174/U, 188/U, 316/U RD-316 Plating Nickel Gold Nickel Gold Nickel Gold M/A-COM Model No. 5831-5002-10 5831-5002-09 5831-5003-10 5831-5003-09 5831-7316-10 5831-7316-09 Part No. 1060869-1 1060868-1 1060872-1 1060871-1 1060875-1 1060875-2 Note: For full crimp attachment consult AMP Right Angle Cable Plug, Crimp 12.00 Ref. [.472] 5.00 Sq. [.197] 3.50 [.137] 6.15 [.242] 7.92 [.312] MCX Plug Cable RG-178/U, 196/U RG-188/U, 316/U RG-179/U, RG-187/U RD-316 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Plating Nickel Gold Nickel Gold Nickel Gold M/A-COM Model No. 5837-5030-10 5837-5030-09 5837-5025-10 5837-5025-09 5837-5031-10 5837-5031-09 www.amp.com/communications/com Part No. 1329293-1 1329293-2 1330723-1 1330723-3 1363301-1 1363301-2 Specifications subject to change. 199 Catalog 1307191 Revised 10-00 RF Coax Connectors MCX Connectors (Continued) Straight Cable Terminal, PC Board, Without Center Contact A Ref. B 5.80 Dia. [.228] 4.00 [.157] Cable Dim. A Dim. B 11.76 .463 3.94 .155 10.74 .423 2.92 .115 12.01 .473 3.94 .155 11.00 .433 2.92 .115 Plating Nickel Gold Nickel Gold Nickel Gold Nickel Gold RG-174/U, 188/U, 316/U RG-178, 196/U M/A-COM Model No. 5818-5002-10 5818-5002-09 5818-5003-10 5818-5003-09 5818-5004-10 5818-5004-09 5818-5005-10 5818-5005-09 Part No. 1060811-1 1060811-2 1060813-1 1060813-2 1060815-1 1060815-2 1060817-1 1253777-1 17.0 Ref. [.669] Bulkhead Cable Jack 1.40 [.055] 5.00 Max Panel [.197] Thickness 4.80 Dia. [.189] 4.90 Min. [.193] MCX Jack 4.50 [.177] Min. Recommended Mounting Hole Cable RG-178/U, RG-196/U RG-188/U, RG-316/U RD-316 Plating Nickel Gold Nickel Gold Nickel Gold Straight Cable Plug, Direct Solder Attachment For Semi-Rigid Cable 2.16 [.085] Dia. M/A-COM Model No. 5834-7396-10 5834-7396-09 5834-7388-10 5834-7388-09 5834-7316-10 5834-7316-09 Part No. 1060884-1 1060884-2 1060883-1 1060882-1 1060881-1 1060881-2 11.3 [.445] 5.00 Dia. [.197] MCX Plug Cable RG-405/U [.085] .047 200 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Plating Gold Gold M/A-COM Model No. 5801-7985-09 5801-7947-09 Part No. 1060772-1 1060772-2 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors MCX Connectors (Continued) Straight Cable Jack, Direct Solder Attachment 11.9 [.469] 2.16 [.085] Dia. MCX Jack 5.00 Dia. [.197] Cable RG-405/U [.085] .047 Plating Gold Gold Right Angle Plug Receptacle, Direct Solder Attachment M/A-COM Model No. 5802-7985-09 5802-7947-09 7.00 [.276] For Semi-Rigid Cable 2.16 [.085] Dia. Part No. 1060774-1 1060774-2 5.00 [.197] 3.48 [.137] 3.10 Dia. [.122] 7.92 6.15 [.312] [.242] MCX Plug Cable RG-405/U Plating Gold M/A-COM Model No. Part No. 5807-7985-09 1060787-1 6.00 Sq. [.236] Vertical Plug Receptacle, PC Board 5.08 [.200] Typ. 3.94 [.155] 4.45 [.175] 0.91 Sq. [.036] 4 Plcs. 0.97 Dia. [.038] MCX Plug 5.77 [.227] Plating Nickel Gold Vertical Jack Receptacle, PC Board M/A-COM Model No. 5863-0000-10 5863-0000-09 Part No. 1061015-1 1085221-1 A 4.45 [.175] 5.08 Typ. [.200] B 0.97 Dia. [.038] 0.91 Sq. [.036] 4 Plcs. MCX Jack Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dim. A Dim. B 8.28 .326 2.92 .115 9.30 .366 3.94 .155 7.09 .279 1.73 .068 Dimensions are in millimeters over [inches] Plating Nickel Gold Nickel Gold Nickel Gold 6.00 Sq. [.236] M/A-COM Model No. 5862-5002-10 5862-5002-09 5862-5003-10 5862-5003-09 5862-5004-10 5862-5004-09 www.amp.com/communications/com Part No. 1060985-1 1060984-1 1060989-1 1330126-1 1060996-1 1060995-1 Specifications subject to change. 201 Catalog 1307191 Revised 10-00 RF Coax Connectors MCX Connectors (Continued) Vertical End Launch, PC Board 10.31 Ref. [.406] 0.97 Dia. Pin [.038] 4.45 [.175] 1.68 [.066] MCX Jack 3.91 [.154] 4.57 [.180] 6.35 Sq. [.250] 4.70 [.185] Plating Tin Lead M/A-COM Model No. 5862-5018-13 Part No. 1061007-1 Right Angle Jack Receptacle, PC Board A B 6.00 [.236] Sq. 5.08 [.200] Typ. 0.97 [.038] Dia. 0.91 Sq. [.036] 4 Plcs. 9.50 [.374] 6.50 [.256] MCX Jack 3.00 [.118] Dim. A Dim. B 9.93 [.391] 3.94 [.155] 7.72 [.304] 1.73 [.068] 8.92 [.351] 2.92 [.115] Jack Receptacle, Bulkhead Feedthrough Plating Nickel Gold Nickel Gold Nickel Gold M/A-COM Model No. 5864-5001-10 5864-5001-09 5864-5002-10 5864-5002-09 5864-5003-10 5864-5003-09 Part No. 1061023-1 1061022-1 1061027-1 1061026-1 1061030-1 1061029-1 8.70 [.342] 2.50 Max. [.098] Panel .580 [.023] 0.97 Dia. [.038] MCX Jack 4.90 Dia. Min. [.193] 6.50 Dia. [.256] 5.50 Across [.217] Flats Lockwasher .190-56,UNS-2A 6.35 Hex. [.250] 4.50 [.177] Min. Recommended Mounting Hole Plating Nickel Gold 202 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] M/A-COM Model No. 5858-0000-10 5858-0000-09 Part No. 1060960-1 1060959-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors MCX Connectors (Continued) Vertical Jack Receptacle, Surface Mount 5.90 [.231] Ref. 4.45 [.175] 6.00 Sq. [.236] 0.91 Sq. [.036] 4 Plcs. MCX Jack Plating Tin Lead 5.08 [.200] Typ. 0.97 Dia. [.038] M/A-COM Model No. 5862-5007-131 5899-5004-541 Part No. 1061002-1 1061092-1 Tape and Reel packaging. 900 connectors per reel (carrier width 16mm, carrier pitch 12mm). 1 Right Angle Jack Receptacle, Surface Mount 6.00 Sq. [.236] 6.50 [.256] 5.08 [.200] Typ. 0.97 Dia. [.038] 9.50 [.374] 6.50 [.256] 3.50 [.137] Plating Tin Lead 0.91 Sq. [.036] 4 Plcs. MCX Jack M/A-COM Model No. 5864-5008-131 5899-5009-541 Part No. 1061035-1 1061094-1 Tape and reel packaging. 750 connectors per reel (carrier width 24mm carrier pitch 12mm). 1 8.89 [.350] 5.72 [.225] .510 Dia. Via. [.020] 4 Plcs. 5.08 [.200] 1.78 Dia. Pad [.070] 5 Plcs. 2.54 [.100] 11.43 5.08 .953 [.450] [.200] [.375] 2.54 [.100] 4.45 [.175] 2.22 [.088] 4 Plcs. 1 oz. Copper Area Free of Solder Mask Notes: 1. Printed circuit board material: glass epoxy FR-4 or similar; relative permittivity: 4.8, 1 oz. copper clad both sides. 2. These dimensions valid for 1.58 [.062] board thickness. 3. Decimal inch equivalents are shown in parentheses for general information only. Recommended Mounting Pattern for Microstrip Line Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 203 Catalog 1307191 Revised 10-00 RF Coax Connectors MCX Connectors (Continued) Straight Cable Plug, Crimp, 75 Ohm 17.5 [.687] Ø 5.0 [.196] Cable RG 179/U Plating Nickel Right Angle Cable Plug, Crimp, 75 Ohm M/A-COM Model No. 9631-7179-10 Part No. 1362990-1 12.4 [.490] 9.9 [.390] 7.9 [.312] Cable RG 179/U Vertical Plug, PC Board, 75 Ohm 6.1 [.241] Plating Nickel M/A-COM Model No. 9637-7179-10 6.0 Sq. [.236] 6.86 [.270] 6.35 [.250] Part No. 1362991-1 5.08 [.200] Typ. Ø 0.71 [.028] 1.91 Typ. [.075] 0.91 Sq. [.036] 4 Plcs. 2.54 Typ. [.100] Plating Nickel 204 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] M/A-COM Model No. 9662-5000-10 Part No. 1361169-1 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors MCX Connectors (Continued) Vertical Jack, PC Board, 75 Ohm 10.0 [.394] 6.0 Sq. [.236] 5.99 [.236] 3.4 [.134] 1.3 [.051] Thru 5 Plcs. 5.08 [.200] Sq. 0.7 Dia. [.026] 0.8 [.036] Sq. 4 Plcs. 9.4 [.370] 2.54 [.100] 5.08 [.200] 6.4 [.252] Plating Gold M/A-COM Model No. 9664-0000-09 Right Angle Jack, PC Board, 75 Ohm Part No. 1363106-1 6.0 Sq. [.236] 5.1 [.200] Typ. 9.7 ± .305 [.382 ± .012] 4.4 [.175] Ø 0.7 [.028] 3.0 Typ. [.118] 0.9 [.036] Sq. 4 Plcs. 2.5 Typ. [.100] Plating Nickel Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] M/A-COM Model No. 9663-0000-10 Part No. 1362992-1 www.amp.com/communications/com Specifications subject to change. 205 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 206 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMT | QuickGrip SMT | QuickGrip provides optimal cable retention for applications where shock, vibration, and/or cable flexure may be encountered. This unique RF design accepts both flexible and semi-rigid micro-coaxial cables while delivering exceptional RF performance up to 3GHz. Solderless Cable Termination ■ 3.0 [.118] Mated Height ■ Excellent Cable Retention ■ Usable With Flexible and Semi-Rigid Micro-Coaxial Cables ■ Tape and Reel Packaging AMP revolutionary SMT | QuickGrip product line is designed to meet the growing demand for a reliable, low cost system for direct termination of coax to a printed circuit board (PCB). SMT | QuickGrip technology eliminates the requirement to connectorize the coaxial cable, reducing assembly times and, therefore, cost. The SMT | QuickGrip surface mount device occupies less PCB area than conventional through hole coaxial connectors. An innovative microstrip mounting pattern and cable receptacle design ensures excellent grounding and PCB retention. The SMT | QuickGrip cable termination system stands a mere 3.0 [.118] off the board when mated, allowing for closer pitch/spacing when designing a system. The These features make this system extremely versatile for design engineers and offer a reliable, cost effective alternative to direct soldering of cable to the PCB. The cable is inserted into the device by means of a simple self-aligning hand tool, eliminating the requirement for skilled personnel. This system removes the possibility of damaged PCBs and cables which are common quality issues associated with direct solder, while providing superior RF performance. The SMT | QuickGrip accommodates multiple cable insertions allowing easy replacement of cables for repairs. This receptacle is designed for high volume assembly using surface mount technology and is available in tape and reel packaging for pick and place board assembly. Prestripped cables and inter- 6.4 [.250] Ref. mechanical and electrical performance, coupled with its ease of use, ensure it to be a high quality, reliable solution for current and future interconnect needs. AMP is an ISO9001 certified manufacturer and maintains an SPC controlled manufacturing environment. Please call your local Sales or Distribution office for additional information and qualification samples today. series cable pigtails are available as turnkey solutions for your application needs (i.e.: for use in multiboard applications, for connecting antennas to the PCB, or point to point transmission on the same PCB). The SMT | QuickGrip cable termination system is ideal for wireless surface mount applications in handsets, pagers and personal digital assistants (PDA). The SMT | QuickGrip 3.2 Ref. [.120] 1.3 Cable Jacket Cable Braid 1.26 Cable Conductor Cable Dielectric 3.0 Ref. [.120] VSWR Features ■ Connectors 1.22 1.18 1.14 PWB 2.1 Ref. [.083] 1.1 0.3 3.0 Ref. [.120] 0.6 0.9 1.2 1.8 2.1 2.4 2.7 3 FREQUENCY (GHz) Typical VSWR using SMT | QuickGrip with Omni-Flex 200 Cable PWB Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 207 Catalog 1307191 Revised 10-00 RF Coax Connectors SMT | QuickGrip Connectors (Continued) Specifications General Materials Housing: Contacts: Finishes Contacts: Polyphenylene Sulfide (PPS) Copper Alloy Gold Plate over Nickel Electrical Frequency Range: Impedance: Insertion Loss: DWV: VSWR: DC - 3GHz Usable with 50 & 75 Ohm systems .08 √ƒGHz 750 VRMs 1.3:1@ 3GHz (Omni-Flex 100, 200 and .047 [.002] Semi-Rigid) 1.4:1 @ 3GHz (.034 [.001] Semi-Rigid) Mechanical Connector Durability: Tape and Reel Packaging: Force to Disengage by Cam-Out (grams): 5 mating cycles min. (receptacle only) 16 [.629] per EIA-481 Omni-Flex 100 Omni-Flex 200 .034 [.001] Semi-Rigid .047 [.002] Semi-Rigid - 469 typical 543 typical 852 typical 1066 typical Environmental Temperature Rating: Resistance to Solder Heat: –40°C(–40°F) to 105°C(221°F) when mated with Omni-Flex 100 –40°C(–40°F) to 125°C(257°F) when mated with Omni-Flex 200 Infrared, convection, and vapor phase solderable (receptacle only). Maximum reflow time/temperature not to exceed 260°C for 3 minutes. Cable Information Materials: Jacket: Shield: Dielectric: Center Conductor: Minimum Bend Radius: Insertion Loss (PVC and FEP cable only): Center Conductor Resistance: 208 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Omni-Flex 100 (OSMT) PVC Flexible Cable (105°C) Polyvinyl Chloride Silver plated copper wire, 38 AWG, 90% min. coverage PFA or FEP Silver Plated Copper Clad Steel, 30 AWG 9.5 [.375] 1.3dB/m, 0.4 dB/ft. @ 500 MHz 2.0dB/m, 0.6 dB/ft. @ 1 GHz 3.0dB/m, 0.9 dB/ft. @ 2 GHz .26 Ohms per foot average Dimensions are in millimeters over [inches] Omni-Flex 200 (SSMT) FEP Flexible Cable (200°C) Fluorinated Ethylene Propylene Silver plated copper wire, 44 AWG, 90% min. coverage PTFE (Polytetrafluoroethylene) Silver Plated Copper Clad Steel, 30 AWG 6.35 [.250] 1.3dB/m, 0.4 dB/ft. @ 500 MHz 2.0dB/m, 0.5 dB/ft. @ 1 GHz 3.0dB/m, 0.9 dB/ft. @ 2 GHz .26 Ohms per foot average www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMT | QuickGrip PC Board Mount Receptacle Connectors (Continued) Pick and Place Feature 1.3 [.050] Center Contact 3.2 [.125] 3.0 [.120] Ground Contact Center Contact Terminal 0.5 [.020] 6.4 [.250] 1.3 [.050] 3.4 [.135] 7.8 [.305] 4.3 [.169] 2 Plcs. 0.5 [.020] 0.6 [.025] 0.6 2 Plcs. [.024] Ø 0.5 Via. 5 Plcs. [.020] 2.4 [.096] 9.0 [.345] 2.4 [.095] 3.4 [.133] 1.3 1.5 [.058] [.050] Circuit Line Ground Pad 2.5 [.100] 1.3 [.050] 3.8 [.150] 1.0 oz. Copper [.0014] Area Free of Solder Mask Recommended Mounting Pattern for Microstrip Line Description Bulk Packaged 100/bag 700 Piece Reel 2000 Piece Reel M/A-COM Model No. 2318-0000-54 2399-5011-54 2399-5012-54 Part No. 1085456-1 1086008-1 1086009-1 1. Printed wiring board material: glass epoxy FR-4 or similar, relative permitivity: 4.8, 1 oz. copper clad both sides. 2. These dimensions valid for 1.6 [.062] board thickness. Cable Insertion Tool M/A-COM Model No. 2598-5438-54 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Part No. 1088313-1 Specifications subject to change. 209 Catalog 1307191 Revised 10-00 RF Coax Connectors SMT | QuickGrip Connectors (Continued) Inter-Series Cable Assemblies SMA Straight Plug Cable Length A Omni-Flex 100 19.2 Ref. [.755] Omni-Flex 200 Assembly Length (A) 100 [4] 200 [8] 305 [12] 100 [4] 200 [8] 305 [12] M/A-COM Model No. 9970-4100-01 9970-4200-01 9970-4305-01 9980-4100-01 9980-4200-01 9980-4305-01 Part No. 1329187-1 1329187-2 1329187-3 1329174-1 1329174-2 1310432-1 Note: 1. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100 [3.94], ±3 [± .12], 101 to 500 [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] SMA Bulkhead Jack Length A 21.3 Ref. [.837] 6.40 Min. [.250] 6.00 [.235] Min. Recommended Mounting Hole Cable Omni-Flex 100 Omni-Flex 200 Assembly Length (A) 100 [4] 200 [8] 305 [12] 100 [4] 200 [8] 305 [12] M/A-COM Model No. 9970-4100-02 9970-4200-02 9970-4305-02 9980-4100-02 9980-4200-02 9980-4305-02 Part No. 1329173-1 1329173-2 1329173-3 1329175-1 1329175-2 1329175-3 Note: 1. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100 [3.94], ±3 [± .12], 101 to 500 [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] 210 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMT | QuickGrip Connectors (Continued) Inter-Series Cable Assemblies (Continued) SMB Straight Plug Cable Length A Omni-Flex 100 21.9 Ref. [.862] Omni-Flex 200 Assembly Length (A) 100 [4] 200 [8] 305 [12] 100 [4] 200 [8] 305 [12] M/A-COM Model No. 9970-4100-03 9970-4200-03 9970-4305-03 9980-4100-03 9980-4200-03 9980-4305-03 Part No. 1313275-2 1313275-3 1313275-1 1408049-1 1408049-2 1408049-3 Note: 1. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100 [3.94], ±3 [± .12], 101 to 500 [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] SMB Bulkhead Jack Length A Cable 17.1 Ref. [.675] Omni-Flex 100 Omni-Flex 200 4.90 Min. [.192] Assembly Length (A) 100 [4] 200 [8] 305 [12] 100 [4] 200 [8] 305 [12] M/A-COM Model No. 9970-4100-04 9970-4200-04 9970-4305-04 9980-4100-04 9980-4200-04 9980-4305-04 Part No. 1408050-1 1408050-2 1408050-3 1408050-4 1408050-5 1408050-6 Note: 1. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100 [3.94], ±3 [± .12], 101 to 500 [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] 4.40 Min. [.172] Recommended Mounting Hole SMB Right Angle Plug Length A Cable Assembly Length (A) 100 [4] Omni-Flex 100 200 [8] 305 [12] 100 [4] Omni-Flex 200 200 [8] 305 [12] 12.7 Ref. [.500] 14.0 [.550] Part No. 1255378-1 1255378-2 1255378-3 1255378-4 1255378-5 1255378-6 Note: 1. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100 [3.94], ±3 [± .12], 101 to 500 [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] 10.8 [.427] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 M/A-COM Model No. 9970-4100-05 9970-4200-05 9970-4305-05 9980-4100-05 9980-4200-05 9980-4305-05 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 211 Catalog 1307191 Revised 10-00 RF Coax Connectors SMT | QuickGrip Connectors (Continued) Inter-Series Cable Assemblies (Continued) MCX Straight Plug Cable Length A Omni-Flex 100 20.9 Ref. [.822] Omni-Flex 200 Assembly Length (A) 100 [4] 200 [8] 305 [12] 100 [4] 200 [8] 305 [12] M/A-COM Model No. 9970-4100-06 9970-4200-06 9970-4305-06 9980-4100-06 9980-4200-06 9980-4305-06 Part No. 1330400-1 1330400-2 1330400-3 1330400-4 1330400-5 1330400-6 Note: 1. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100 [3.94], ±3 [± .12], 101 to 500 [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] MCX Bulkhead Jack Length A Cable 16.8 Ref. [.662] 4.80 Min. [.189] Ø 4.90 Min. [.192] Omni-Flex 100 Omni-Flex 200 4.50 Min. [.177] 11.4 [.447] Ref. Recommended Mounting Hole Assembly Length (A) 100 [4] 200 [8] 305 [12] 100 [4] 200 [8] 305 [12] M/A-COM Model No. 9970-4100-07 9970-4200-07 9970-4305-07 9980-4100-07 9980-4200-07 9980-4305-07 Part No. 1408051-1 1408051-2 1408051-3 1408051-4 1408051-5 1408051-6 Note: 1. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100 [3.94], ±3 [± .12], 101 to 500 [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] MCX Right Angle Plug Cable Length A Omni-Flex 100 10.8 Ref. [.425] Omni-Flex 200 7.90 [.312] 6.10 [.241] Assembly Length (A) 100 [4] 200 [8] 305 [12] 100 [4] 200 [8] 305 [12] M/A-COM Model No. 9970-4100-08 9970-4200-08 9970-4305-08 9980-4100-08 9980-4200-08 9980-4305-08 Part No. 1330401-1 1330401-2 1330401-3 1330401-4 1330401-5 1330401-6 Note: 1. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100 [3.94], ±3 [± .12], 101 to 500 [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] 50 Ohm D-sub Coaxial Receptacle Cable Omni-Flex 100 Length A 25.6 Ref. [1.01] Omni-Flex 200 Assembly Length (A) 100 [4] 200 [8] 305 [12] 100 [4] 200 [8] 305 [12] M/A-COM Model No. 9970-4100-09 9970-4200-09 9970-4305-09 9980-4100-09 9980-4200-09 9980-4305-09 Part No. 1408052-1 1408052-2 1408052-3 1408052-4 1408052-5 1408052-6 Note: 1. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100 [3.94], ±3 [± .12], 101 to 500 [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] 212 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SMT | QuickGrip Connectors (Continued) Pre-Stripped Cables Cable Type Omni-Flex 100 (OSMT Cable) Omni-Flex 200 (SSMT Cable) .034 [.001] Semi-Rigid .047 [.002] Semi-Rigid Description Pre-Stripped Omni-Flex Cables for use with SMT | QuickGrip Pre-Stripped Omni-Flex Cables for use with SMT | QuickGrip Pre-Stripped Omni-Flex Cables for use with SMT | QuickGrip Pre-Stripped Omni-Flex Cables for use with SMT | QuickGrip Cable Length 100 [4] 200 [8] 305 [12] M/A-COM Model No. 9970-1100-23 9970-1200-23 9970-1305-23 Part No. 1255379-1 1310520-1 1313265-1 100 [4] 200 [8] 305 [12] 9980-1100-23 9980-1200-23 9980-1305-23 1313334-1 1310521-1 1408074-1 100 [4] 200 [8] 305 [12] 9921-1100-23 9921-1200-23 9921-1305-23 1408075-1 1408075-2 1408075-3 100 [4] 200 [8] 305 [12] 9922-1100-23 9922-1200-23 9922-1305-23 1408075-4 1408075-5 1408075-6 Notes: 1. Cables should be ordered in 5mm increments. 2. Will Accept: RG 178, RG 196 When Stripped and Pre-Tinned. 3. Cable length tolerances: Length ‘A’ mm [In], Tolerance mm [In], 50 to 100mm [3.94], ±3 [± .12], 101 to 500mm [3.98 to 19.69], ±5 [± .20], Over 500 [19.69], ±10 [± .39] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 213 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 214 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp\communications\com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SSMT Surface Mount Interconnect System Microminiature Surface Mount RF Connectors Features ■ 3.0 [.118] mated height ■ Excellent interface retention ■ Flexible micro-coax cable ■ 360 degree mated rotation ■ Tape and Reel packaging available The AMP next generation SSMT surface mount Interconnect System is designed to provide superior electrical and mechanical performance for wireless communication applications. The SSMT system occupies less printed circuit board (PCB) real estate than conventional through hole coaxial connectors. An innovative microstrip mounting pattern and plug receptacle design ensure reliable grounding and PCB retention characteristics. The SSMT Interconnect System allows closer pitch/spacing, standing 3.0 [.118] (fully mated height) off the board. The mated SSMT interface allows 360 degrees of rotation providing maximum PCB design flexibility. It has been designed to provide optimal retention for appli- Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] cations where shock, vibration or cable flexure may be encountered. Force to disengage by cable load (camout) exceeds 300 grams. The SSMT system is designed to provide the performance of much larger industry standard connectors. The SSMT Interconnect System consistently achieves broad band electrical performance through 6 GHz with a maximum VSWR of 1.20:1 at 2 GHz. This broad band performance establishes a reliable interface that can be utilized for future system upgrades without concern for performance degradation. The SSMT utilizes a common OSMT plug receptacle, part number 1251802-1, which is designed for high volume assembly using sur- face mount technology and is available in tape and reel packaging for automatic pick and place board assembly. The mating cable jack is available terminated to a highly flexible microcoax cable as either a pigtail, jumper or standard interseries connector assembly to meet your needs. The SSMT Interconnect System can be manually mated, facilitating high volume assembly and eliminating the need for special engagement tooling. The SSMT interface design aligns the center contacts prior to full mating to ensure a robust mechanical engagement. Interface durability is rated at 100 mating cycles. www.amp.com/communications/com Specifications subject to change. 215 Catalog 1307191 Revised 10-00 RF Coax Connectors SSMT Surface Mount Interconnect System (Continued) Specifications General Materials SMT Plug Housing: Polyphenylene Sulfide (PPS) Contacts: Copper Alloy Outer Contact: Beryllium Copper Inner Contact: Beryllium Copper Dielectric: Polypropylene, GF Plug and cable jack - Contacts: Gold plate over nickel plate SSMT™ Cable Jack Finish Electrical Frequency Nominal Impedance Voltage Rating VSWR (Mated Pair) Insulation Resistance Dielectric Withstanding Voltage Contact Resistance (Connectors Only) Center Contact Outer Contact Insertion Loss (Connectors Only) dc - 6 GHz 50 Ohms 250 Volts (VRMS Maximum) @ Sea Level 1.20:1 Maximum @ 2 GHz 1.40:1 Maximum @ 6 GHz 5000 Megohms Minimum 500 Volts (VRMS Minimum) @ Sea Level 15 milliohms Maximum 10 milliohms Maximum .15dB Max. @ 6 GHz Mechanical Connector Durability Tape/Reel Packaging (Plug) Force to Engage Force to Disengage Force to Disengage by Cable Load (camout) 100 mating cycles 12mm per EIA-481 5.5 lbs. Max. (3.5 lbs. typ.) (2.0 lbs. typ.) 4.0 lbs. Max. (2.0 lbs. typ.) 300 Grams Min. (800 Grams typ. initial mate) Environmental Temperature Rating (Mated Pair) Resistance to Solder Heat -40°C (-40°F) to +125°C (257°F) Infrared, convection and vapor phase solderable (plug only). Maximum reflow time/temperature not to exceed 260°C for 3 minutes. Cable Specifications Materials Jacket: Shield: Dielectric: Center Conductor: Minimum Bend Radius Insertion Loss (Cable Only) FEP (polytetrafluoroethylene) Silver plated copperwire, 44 AWG, 90% min. coverage PTFE ( polytetrafluoroethylene) Silver plated copper clad steel, 30 AWG 6.35mm (.250 inch) 0.5 dB/ft., 2.0 dB/m @ 1 GHz 0.9 dB/ft., 3.0 dB/m @ 2 GHz .25 Ohms per foot average. 819 milliohm/meter Nom.; 250 milliohm/Ft. Nom. Center Conductor Resistance 1.3 Dia. Ref. [.052] Outer Jacket 216 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] 1.0 Dia. Ref. [.040] Shield (Braid) 0.8 Dia. Ref. [.030] Dielectric 0.3 Dia. Ref. [.010] Center Conductor www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SSMT Surface Mount Interconnect System (Continued) Straight SMT PCB Mount Plug Receptacle Ground Terminal (3 Plcs.) 4.5 [.177] 2.1 [.081] Center Contact (Pin) 4.0 [.157] 2.1 [.049] 5.0 [.197] 4.5 [.177] 0.4 [.015] 1.0 [.039] 4 Plcs. Center Contact Terminal Outer Contact Packaging Bulk 178 Dia. Taping 7.0 330 Dia. Taping 13.3 1.2 [.047] 0.6 [.025] 3.0 [.118] Center Contact Terminal Quantity Multiple of 100 M/A-COM Model No. 2367-0000-54 Part No. 1251802-1 800 pcs/reel 2367-5001-54 1083946-1 3000 pcs/reel 2367-5002-54 1055689-1 5.3 [.207] 0.5 VIA Holes [.020] 3 Plcs. 0.5 [.020] 4 Plcs. 2.9 [.113] 1.6 (See Note 2) [.064] (See Note 2) 0.6 [.024] 1.2 [.047] 1.2 [.047] 7.0 [.274] 9.0 [.354] Notes: 3.0 6.0 [.118] [.236] 0.5 [.019] 3.3 [.128] 1.2 [.047] 3.3 [.128] 1. Printed wiring board material: glass epoxy. FR-4 or similar, relative permittivity: 4.8, 1 oz. copper clad both sides. 1 oz. Copper [.0014] 2. These dimensions valid for 1.6 [.062] board thickness. Area Free of Solder Mask Recommended Mounting Pattern for Microstrip Line Right Angle Jack to Jack Cable Assembly Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. 9960-1100-24 9960-1200-24 9960-1304-24 Part No. 1044764-1 1064530-1 1064533-1 3.4 Ref. [.132] 2.1 Ref. [.081] 5.3 Ref. [.208] SSMT Jack Length A Centerline to Centerline 1.3 Ref. [.052] Cable 2.5 Dia. [.100] Ref. Notes: 1. Consult AMP for non-standard cable lengths. Length A Tolerances. Length A Tolerance 50 To 100 [3.94] ± 3 [± .12] 101 To 500 [3.98 to 19.69] ± 5 [± .20] Over 500 [19.69] ± 10 [± .39] 2. Connector centerlines align ±30° as shown for lengths of 165 [6.5] or less. Cable assemblies over 165 [6.5] have randomly aligned connectors. 3. SSMT Jack is not mateable with OSMT High Retention plug receptacle (1055690-1) Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 217 Catalog 1307191 Revised 10-00 RF Coax Connectors SSMT Surface Mount Interconnect System (Continued) Right Angle Jack to Jack Cable Assembly (180° Offset) Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. Part No. 9960-3100-24 1082845-1 9960-3200-24 1082846-1 9960-3305-24 1082847-1 Length A Centerline to Centerline 2.1 Ref. [.081] 5.3 Ref. [.208] Ø 2.5 [.100] 1.3 Ref. Cable [.052] SSMT Jack Notes: 1. Consult AMP for non-standard cable lengths. Cable length tolerance: Length A Tolerances. Length A Tolerance 50 To 100 [3.94] ± 3 [± .12] 101 To 500 [3.98 to 19.69] ± 5 [± .20] Over 500 [19.69] ± 10 [± .39] 2. SSMT Jack is not mateable with OSMT High Retention Plug receptacle (1055690-1). 3. To avoid damaging the cable, minimize time at temperature while soldering and/or applying heat to unterminated end of cable. Right Angle Jack Cable Pigtail Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] 510 [20.0] M/A-COM Model No. 9960-2100-24 9960-2200-24 9960-2305-24 9960-2510-24 Part No. 1064535-1 1064538-1 1064540-1 1064542-1 3.4 Ref. [.132] 2.1 Ref. [.081] 5.3 Ref. [.208] Length A Centerline to Cable End SSMT Jack 2.5 Dia. [.100] Ref. 218 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 1.3 Ref. Cable [.052] Dimensions are in millimeters over [inches] Notes: 1. Consult AMP for non-standard cable lengths. Cable length tolerance: Length A Tolerances. Length A Tolerance 50 To 100 [3.94] ± 3 [± .12] 101 To 500 [3.98 to 19.69] ± 5 [± .20] Over 500 [19.69] ± 10 [± .39] 2. SSMT Jack is not mateable with OSMT High Retention Plug receptacle (1055690-1). 3. To avoid damaging the cable, minimize time at temperature while soldering and/or applying heat to unterminated end of cable. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SSMT Surface Mount Interconnect System (Continued) Inter-Series Cable Assemblies Notes: 1. Consult AMP for non-standard cable lengths: Length A Tolerances. Length A Tolerance 50 To 100 (3.94) ± 3 (± .12) 101 To 500 (3.98 to 19.69) ± 5 (± .20) Over 500 (19.69) ± 10 (± .39) 2. Connectors are randomly aligned unless otherwise noted. 3. SSMT Jack is not mateable with OSMT High Retention Plug receptacle (1055690-1). SMA Straight Plug Length A Reference Plane to Centerline 19.2 Ref. 1.3 Dia. Ref. [.757] [.052] Cable 3.4 Ref. [.132] Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] 2.1 Ref. [.081] M/A-COM Model No. 9960-4100-01 9960-4200-01 9960-4305-01 Part No. 1064543-1 1064552-1 1064560-1 SSMT Right Angle Jack Note: 1064552-1 recommended for customer system verification. 2.5 Dia. Ref. [.100] SMA Bulkhead Jack Length A Reference Plane to Centerline 1.3 21.3 Ref. [.052] [.839] Dia. Ref. Cable 3.4 Ref. [.132] 2.5 Dia. Ref. [.100] SSMT Right 3.2 Max. Panel Angle Jack [.125] Thickness 7.9 Hex. [.312] 5.4 Dia. [.250] Min. 2.1 Ref. [.081] Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. 9960-4100-02 9960-4200-02 9960-4305-02 Part No. 1064544-1 1064553-1 1064561-1 Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. 9960-4100-03 9960-4200-03 9960-4305-03 Part No. 1064545-1 1064554-1 1064562-1 6.0 [.235] Min. Recommended Mounting Hole SMB Straight Plug Length A Reference Plane to Centerline 1.3 21.9 Ref. [.052] [.862] Dia. Ref. Cable 3.4 Ref. [.132] 2.1 Ref. [.081] SSMT Right Angle Jack 2.5 Dia. Ref. [.100] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 219 Catalog 1307191 Revised 10-00 RF Coax Connectors SSMT Surface Mount Interconnect System (Continued) Inter-Series Cable Assemblies (Continued) SMB Bulkhead Jack 7.4 [.290] Length A Reference Plane to Centerline 17.1 Ref. 1.3 [.675] [.052] Dia. Ref. Cable 3.4 Ref. [.132] 4.9 Dia. [.192] Min. 2.1 2.1 Ref.Ref. [.081]081] Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. 9960-4100-04 9960-4200-04 9960-4305-04 Part No. 1064546-1 1064555-1 1064563-1 Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. 9960-4100-05 9960-4200-05 9960-4305-05 Part No. 1064547-1 1064556-1 1064564-1 Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. 9960-4100-06 9960-4200-06 9960-4305-06 Part No. 1064548-1 1064557-1 1064565-1 Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. 9960-4100-07 9960-4200-07 9960-4305-07 Part No. 1064549-1 1064558-1 1064566-1 4.4 4.4 2.5 [.172] [.172] [.100] Min.Min. Dia. Ref. SSMT Right ht Re Recommended 2.4 Max. Panel Angle Jack k Mo Mounting Hole [.093] Thickness 7.9 Hex. [.312] 6.4 Hex. [.250] SMB Right Angle Plug Length A Centerline to Centerline 12.7 Ref. [.500] 14.0 [.550] 10.8 [.427] 1.3 [.052] Dia. Ref. Cable 3.4 Ref. [.132] 2.1 Ref. [.081] SSMT Right Angle Jack 2.5 Dia. Ref. [.100] MCX Straight Plug Length A Reference Plane to Centerline 1.3 20.9 Ref. [.052] [.822] Dia. Ref. Cable 3.4 Ref. [.132] 2.1 Ref. [.081] SSMT Right Angle Jack 2.5 Dia. Ref. [.100] MCX Bulkhead Jack Length A Reference Plane to Centerline 1.3 16.8 Ref. [.052] [.662] Dia. Ref. Cable 4.8 Dia. [.189] 6.4 [.250] Max. Panel Thickness 220 11.4 [.447] 6.4 [.250] Hex. 3.4 Ref. [.132] 2.1 2.1 Ref. Ref. [.081] 081] 4.9 Dia. [.192] Min. 2.5 Dia. Ref. 4.5 Min. [.100] [.177] SSMT Rightht Recommended Angle Jack k Recom Mount Mounting Hole Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors SSMT Surface Mount Interconnect System (Continued) Inter-Series Cable Assemblies (Continued) MCX Right Angle Plug Length A Centerline to Centerline 3.4 Ref. [.132] 1.3 [.052] Dia. Ref. Cable 2.1 Ref. [.081] 12.7 [.500] Ref. 6.1 [.241] SSMT Right Angle Jack 7.9 [.312] Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. 9960-4100-08 9960-4200-08 9960-4305-08 Part No. 1064550-1 1064559-1 1064567-1 Assembly Length (A) 100 [4.0] 200 [8.0] 305 [12.0] M/A-COM Model No. 9960-4100-09 9960-4200-09 9960-4305-09 Part No. 1064548-1 1064554-1 1064568-1 2.5 Dia. Ref. [.100] 50 Ohm D-Sub Coaxial Receptacle Length A Reference Plane to Centerline 3.4 Ref. [.132] 1.3 [.052] Dia. Ref. Cable 31.8 Ref. [1.250] 2.1 Ref. [.081] SSMT Right Angle Jack 2.5 Dia. Ref. [.100] Tools 101.6 Ref. [4.00] SSMT Disengagement Tool M/A-COM Model No. 2598-5342-54 SLIDE HORIZONTAL TO ENGAGE TOOL LIFT VERTICAL TO DISENGAGE CONNECTOR Part No. 1221286-1 PRESS VERTICAL TO ENGAGE CONNECTOR OPTIONAL Use of Engagement/Disengagement Tool Note: The SSMT disengagement tool can be utilized as an optional engagement tool versus manual hand installation. Adapters SSMT to SMA Between Series Adapters SSMT Plug to SMA Jack Adapter SSMT Plug to SMA Plug Adapter 13.7 Ref. [.538] 5.5 Across Flats [.218] SMA Jack SSMT Plug 5.5 Across Flats [.218] SSMT Jack SMA Jack SMA Plug SSMT Plug SSMT Jack to SMA Plug 16.2 Ref. [.639] SMA Plug SSMT Jack 12.9 Ref. [.508] 10.5 Ref. [.413] M/A-COM Model No. 2382-2240-00 SSMT Jack to SMA Jack Adapter Part No. 1055696-1 M/A-COM Model No. 2381-2241-00 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 1055695-1 Dimensions are in millimeters over [inches] M/A-COM Model No. 2380-2240-00 Part No. 1055694-1 M/A-COM Model No. 2382-2241-00 www.amp.com/communications/com Part No. 1055697-1 Specifications subject to change. 221 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 222 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSMT Interconnect System Surface Mount Coaxial Connectors Features ■ ■ ■ ■ Occupies less (PCB) realestate than conventional through hole connectors 4.2 [.165] fully mated height off PCB Performance through 6GHz Tape & reel packaging available Applications ■ ■ ■ Telecommunications GPS Consumer & automotive electronics The OSMT Interconnect System is designed to meet the growing demand for surface mount RF connector technology. The OSMT occupies less printed circuit board (PCB) real estate than conventional through hole coaxial connectors. An innovative microstrip mounting pattern and plug receptacle design ensure reliable grounding and PCB retention characteristics. The OSMT Interconnect System also allows closer PCB pitch/spacing, standing a mere 4.2 [.165] (fully mated height) off the board. A new higher cable retention plug receptacle has been added to the OSMT product family. This new design addresses applications where force is applied to the mated connector interface as a result of cable flexure between boards or around other PCB components. The OSMT Interconnect System consistently achieves broad band electrical performance through 6 GHz with a maximum VSWR of 1.20:1 at 2 GHz and 1.40:1 at 6 GHz. This broad band performance establishes a reliable interface that can be utilized for future system upgrades without concerns for performance degradation. The OSMT plug receptacle is designed for high volume assembly using surface mount technology and is available in tape and reel packaging for automated pick and place board assembly. The mating cable jack is available terminated to a specially designed coax cable as either a pigtail, jumper or standard interseries connector assembly. Specially designed engage/ disengage tooling is available to ensure proper alignment of the OSMT interface during assembly. The higher retention plug receptacle can be hand engaged as a result of a unique lead-in chamfer design which also aligns the contacts prior to mating to ensure mechanical integrity. Interface durability is rated at 100 mating cycles. The OSMT Interconnect System is ideal for surface mount applications in telecommunictions, GPS, consumer and automotive electronics. The OSMT provides versatile RF solutions for next generation interconnect needs. High Retention Design 360° Cable Rotation 4.20 Max. [.165] Mated Profile Slotted Cable Entry 4.20 Max. [.165] Mated Profile OSMT Right Angle Jack 5.30 Min. [.208] Clearance For Disengagement M/A-COM Model Number 2367-0000-54 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 OSMT Plug Part No. 1251802-1 OSMT Right Angle Jack 6.20 Min. [.245] Clearance For Disengagement M/A-COM Model Number 2367-5006-54 Dimensions are in millimeters over [inches] OSMT Plug Part No. 1055690-1 www.amp.com/communications/com Specifications subject to change. 223 Catalog 1307191 Revised 10-00 RF Coax Connectors OSMT Surface Mount Coaxial Connectors Specifications General Materials OSMT Plug Housing: Polyphenylene Sulfide Contacts: Copper alloy Outer Contact: Beryllium Copper Inner Contact: Beryllium Copper Dielectric: Polypropylene, GF Plug and cable jack - Contacts: Gold plate over nickel plate OSMT Cable Jack Finish Electrical Frequency Nominal Impedance Voltage Rating VSWR (Mated Connectors Only) dc - 6 GHz 50 ohms 250 Volts (VRMS Maximum) @ Sea Level 1.20:1 Maximum @ 2 GHz 1.40:1 Maximum @ 6 GHz 1000 Megohms Minimum 500 Volts (VRMS Minimum) @ Sea Level Insulation Resistance Dielectric Withstanding Voltage Contact Resistance (Connectors Only) Center Contact Outer Contact Insertion Loss (Connectors Only) 15 milliohms Maximum 10 milliohms Maximum .15dB Max. @ 6 GHz Mechanical Connector Durability Tape/Reel Packaging (Plug) Force to Engage Force to Disengage 100 mating cycles 12mm per EIA-481 4.0 lbs. Max. (2.5 lbs. typ.) 4.5 lbs. Max. (3.0 lbs. typ.) Environmental Temperature Rating (Mated Pair) Resistance to Solder Heat PVC Flexible Cable: -40°C (-40°F) to +105°C (221°F) Infrared, convection and vapor phase solderable (plug only). Maximum reflow time/temperature not to exceed 260°C for 3 minutes. Cable Specifications Materials Jacket: Shield: PVC Flexible Cable (105°C) Polyvinyl Chloride Silver Plated Copper Wire, 38 AWG, 90% Min. Coverage PFA or FEP Silver Plated Copper Clad Steel, 30 AWG 9.5 [.375] 0.4 dB/ft., 1.3d B/m @ 500 MHz 0.6 dB/ft., 2.0 dB/m @ 1 GHz 0.9 dB/ft., 3.0 dB/m @ 2 GHz Dielectric: Center Conductor: Minimum Bend Radius Insertion Loss (PVC and FEP Cable Only) Center Conductor Resistance (PVC and FEP Cable Only) .26 Ohms per foot average .254 Dia. [.010] Ref. 1.30 Dia. [.052] 0.73 Dia. [.028] 224 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] 1.90 Dia. [.075] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSMT Surface Mount Coaxial Connectors (Continued) Straight SMT PCB Mount Plug Receptacles Multi-directional cable entry, 360° rotation. Recommended for use in passive cable applications or with supplementary cable tie-downs. 4.50 [.177] 4.50 [.177] 4.00 [.157] 2.10 [.081] 4.00 Ref. [.157] 5.00 [.197] 4.50 Ref. [.177] 1.00 [.039] 4 Plcs. 3.00 [.118] Packaging Quantity M/A-COM Model No. Part No. Bulk Customer Specified 2367-0000-54 1251802-1 178 7.0 Dia. Taping 330 13.3 Dia. Taping 800 pcs/reel 2367-5001-54 1083946-1 3000 pcs/reel 2367-5002-54 1055689-1 Note: Requires part number 1221286-1 Engagement/Disengagement Tool. 4.50 [.177] Slotted single direction cable entry. Recommended for use in applications where bending forces may be applied to the cable. 3.00 [.118] 4.00 [.157] 4.00 Ref. [.157] 5.00 4.50 [.197] [.177] 4.50 Ref. [.177] 1.00 [.039] 4 Plcs. 3.00 [.118] Packaging Quantity M/A-COM Model No. Part No. Bulk Customer Specified 2367-5006-54 1055690-1 178 7.0 Dia. Taping 330 13.3 Dia. Taping 600 pcs/reel 2367-5015-54 1254242-1 2500 pcs/reel 2367-5016-54 1055692-1 Note: Requires part number 1055886-1 Disengagement Tool. Engagement requires no tooling. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 225 Catalog 1307191 Revised 10-00 RF Coax Connectors OSMT Surface Mount Coaxial Connectors (Continued) Right Angle Jack to Jack Cable Assembly 180° Offset 2.80 Dia. [.110] Ref. 2 Plcs. 3.10 Ref. [.122] 1 Cable Length Centerline To Centerline Cable Lengths 100 4.0 200 8.0 305 12.0 M/A-COM Model No. Part No. 9950-3100-23 1064353-1 9950-3200-23 1064357-1 9950-3305-23 1064358-1 Notes: 1. Consult AMP for non-standard cable lengths. 2. Connector centerlines align 180° ± 30° as shown. 3. Cable length tolerance: 50.0 [1.97]-20000.0 [787.4]: ± (2.0 [0.08] +1% of cable length) 1 Right Angle Jack to Jack Cable Assembly Cable Length Centerline To Centerline 3.10 Ref. [.122] 2.80 Dia. [.110] Ref. 2 Plcs. Cable Lengths 100 4.0 200 8.0 305 12.0 M/A-COM Model No. Part No. 9950-1100-23 1064303-1 9950-1200-23 1064309-1 9950-1305-23 1064315-1 Notes: 1. Connectors are randomly aligned. 2. Consult AMP for non-standard cable lengths. Cable length tolerance: 50.0 [1.97]-20000.0 [787.4]: ± (2.0 [0.08] +1% of cable length) 226 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSMT Surface Mount Coaxial Connectors (Continued) Inter-Series Cable Assemblies SMA Straight Plug Cable Length 19.2 Ref. [.755] Ø 1.90 Ref. [.075] Cable 3.10 Ref. [.122] Ø 2.80 [.110] Ref. 6.35 [.250] Cable Length 100 4.0 200 8.0 305 12.0 SMA Bulkhead Feed Through Jack M/A-COM Model No. Part No. 9950-4100-01 1064367-1 9950-4200-01 1064391-1 9950-4305-01 1064409-1 Cable Length 21.3 Ref. [.837] Ø 1.90 Ref. [.075] Cable Ø 6.40 [.250] Min. 3.10 Ref. [.122] Ø 2.80 [.110] Ref. 6.35 [.250] 6.00 [.235] Min. Recommended Mounting Hole Cable Length 100 4.0 200 8.0 305 12.0 M/A-COM Model No. Part No. 9950-4100-03 1064369-1 9950-4200-03 1064393-1 9950-4305-03 1064411-1 Cable Length SMB Straight Plug Ø 1.90 Ref. [.075] Cable 21.9 Ref. [.862] 6.35 [.250] Cable Length 100 4.0 200 8.0 305 12.0 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 3.10 Ref. [.122] Ø 2.80 [.110] Ref. M/A-COM Model No. Part No. 9950-4100-08 1081124-1 9950-4200-08 1064397-1 9950-4305-08 1064414-1 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 227 Catalog 1307191 Revised 10-00 RF Coax Connectors OSMT Surface Mount Coaxial Connectors (Continued) Inter-Series Cable Assemblies (Continued) SMB Bulkhead Feed Through Jack Cable Length 17.1 Ref. [.675] Ø 1.90 Ref. [.075] Cable Ø 4.90 Min. [.192] 3.10 Ref. [.122] Ø 2.80 [.110] Ref. 6.35 [.250] 4.40 [.172] Min. Recommended Mounting Hole Cable Length 100 4.0 200 8.0 305 12.0 MCX Straight Plug M/A-COM Model No. Part No. 9950-4100-10 1408002-1 9950-4200-10 1064399-1 9950-4305-10 1408002-2 Cable Length Ø 1.90 Ref. [.075] Cable 20.9 Ref. [.822] Ø 2.80 [.110] Ref. 6.35 [.250] Cable Length 100 4.0 200 8.0 305 12.0 M/A-COM Model No. Part No. 9950-4100-15 1064374-1 9950-4200-15 1408003-1 9950-4305-15 1408003-2 MCX Right Angle Plug Cable Length 10.8 Ref. [.425] 7.90 [.312] Ø 1.90 Ref. [.075] Cable 6.10 [.241] 6.35 [.250] Cable Length 100 4.0 200 8.0 305 12.0 228 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 3.10 Ref. [.122] 3.10 Ref. [.122] Ø 2.80 [.110] Ref. M/A-COM Model No. Part No. 9950-4100-16 1064375-1 9950-4200-16 1064401-1 9950-4305-16 1064416-1 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSMT Surface Mount Coaxial Connectors (Continued) Inter-Series Cable Assemblies (Continued) SMB Right Angle Plug Cable Length Ø 1.90 Ref. [.075] Cable 14.0 [.550] 10.8 [.427] 3.10 Ref. [.122] Ø 2.80 [.110] Ref. 6.35 [.250] Cable Length 100 4.0 200 8.0 305 12.0 MCX Bulkhead Jack M/A-COM Model No. Part No. 9950-4100-27 1408004-1 9950-4200-27 1408004-2 9950-4305-27 1408004-3 Cable Length 16.8 Ref. [.662] 4.80 Dia. [.189] Ø 1.90 Ref. [.075] Cable 11.4 Ref. [.447] Ø 4.90 Min. [.192] 3.10 Ref. [.122] Ø 2.80 [.110] Ref. 6.35 [.250] 4.50 [.177] Min. Recommended Mounting Hole Cable Length 100 4.0 200 8.0 305 12.0 50 Ohm D-Sub Coaxial Receptacle M/A-COM Model No. Part No. 9950-4100-38 1408005-1 9950-4200-38 1408005-2 9950-4305-38 1408005-3 Cable Length 25.6 Ref. [1.01] Ø 1.90 Ref. [.075] Cable 6.35 [.250] Cable Length 100 4.0 200 8.0 305 12.0 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Ø 4.90 Min. [.192] 3.10 Ref. [.122] 4.50 [.177] Min. Ø 2.80 [.110] Ref. Recommended Mounting Hole M/A-COM Model No. Part No. 9950-4100-39 1408006-1 9950-4200-39 1408006-2 9950-4305-39 1408006-3 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 229 Catalog 1307191 Revised 10-00 RF Coax Connectors OSMT Surface Mount Coaxial Connectors (Continued) Right Angle Jack Cable Pigtail Cable Length1 Cable Length 100 4.0 200 8.0 305 12.0 M/A-COM Model No. Part No. 9950-2100-23 1064331-1 9950-2200-23 1064333-1 9950-2305-23 1064338-1 Note: 1. Consult AMP for non-standard cable lengths. Cable length tolerance: 50.0 [1.97]-20000.0 [787.4]: ± (2.0 [0.08] +1% of cable length) 2. To avoid damaging the cable, minimize time at temperature while soldering and/or heat shrinking connector to the cable. SMA Straight Plug (Male) Recommended for Customer System Verification Cable Length1 Centerline To Reference Plane Cable Length M/A-COM Model No. PVC Flexible Cable Part No. 200 8.0 9950-4200-01 1064391-1 Finish: SMA, Passivated stainless steel body and gold plated center contact. Tools 6.40 [.250] Engagement/Disengagement Tool 101.6 [4.00] M/A-COM Model No. Part No. 2598-5342-54 1221286-1 See Application Notes for instructions. For use with 1251802-1 plug only Disengagement Tool 9.50 Ref. [.375] 6.40 [.250] M/A-COM Model No. Part No. 2598-5401-54 1055886-1 See Application Notes for instructions. For use with 1055690-1 plug only 230 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors OSMT Surface Mount Coaxial Connectors (Continued) OSMT Plug to SMA Jack Adapter SMA Jack SSMT Plug M/A-COM Model No. Part No. 2382-2240-00 1055696-1 M/A-COM Model No. Part No. 2381-2241-00 1055695-1 M/A-COM Model No. Part No. 2380-2240-00 1055694-1 M/A-COM Model No. Part No. 2382-2241-00 1055697-1 10.5 Ref. [.413] 13.7 Ref. [.538] OSMT Plug to SMA Plug Adapter SSMT Plug SMA Plug OSMT Jack to SMA Jack Adapter SMA Jack SSMT Jack 12.9 Ref. [.508] 16.2 Ref. [.639] OSMT Jack to SMA Plug SMA Plug Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] SSMT Jack www.amp.com/communications/com Specifications subject to change. 231 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 232 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series MMCX (50 Ohm) tors are suitable for use up to 6 GHz and are provided with a reliable snap-on coupling. Series MMCX connectors are easy and fast to assemble. Micro miniature connectors series MMCX (size 0.7/1.6; CECC 22340) are primarily intended for applications where minimum dimensions and space-saving design are required. The connec- This connector family contains straight and right angled variants for cable or solder connection and SMD connectors for surface mounting technology onto PC boards. Jack Plug 2.6 Min. [0.10] 2.7 [0.11] 1.2 [0.05] 0.25 Max. [0.01] Ø 0.7 [0.03] Ø 0.4 [0.02] Ø 1.6 Ø 2.4 [0.06] [0.09] 1.45 [0.06] Min. Ø 3.5 Ø 2.4 [0.14] [0.09] ECN1130-J Reference Plane Reference Plane Interface Dimensions Technical Data Electrical and mechanical characteristics in accordance with CECC 22340 Characteristic impedance — 50 Ω Frequency range — up to 6 GHz Reflection factor1, referred to — Flexible cables — straight connector, r ≤ 0.10 angle connector, r ≤ 0.15 Insulation resistance — initial value ≥ 1 GΩ after stressing ≥ 500 MΩ Inner conductor contact resistance — after stressing ≤ 15 mΩ Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Outer conductor continuity — after stressing ≤ 7.5 mΩ Voltage proof (at sea level) — 500 V, 50 Hz Working voltage (at sea level) — Flexible cables (RG 178) — 170 V, 50 Hz Semi-rigid cables (RG 405) — 250 V, 50 Hz Screening effectiveness2 — ≥ 60 dB Engagement (axial force) — 20 N max. Separation — 6 N min., 20 N max. Tensile strength of cable clamping device — RG 178 = 32 N min. RG 405 = 100 N min. Service life — 500 cycles Climatic category — 55/155/21 1 Guideline values, depending on cable type and connector style. 2 Straight connector; 1 GHz www.amp.com/communications/com Specifications subject to change. 233 Catalog 1307191 Revised 10-00 RF Coax Connectors Series MMCX (50 Ohm) (Continued) Plug, Full Crimp Cable Ø 3.5 [0.14] RG 405 RG 178 ECN1132-1 RG 196 a RG 316 Right Angle Plug, Solder/Crimp 4.0 [0.16] 7.0 [0.28] 3.5 [0.14] Cable RG 405 5.3 [0.21] RG 178 RG 196 a Vertical PC Board Mount Jack RG 316 ECN1134-H 3.5 [0.14] Reference Plane Ø 0.7 [0.03] 4.5 [0.18] Dim a 11.5 0.45 11.5 0.45 11.5 0.45 15 0.59 Ø Max. 2.25 0.09 1.9 0.07 2.1 0.08 2.6 0.10 Dim a 9.0 0.35 9.0 0.35 9.0 0.35 11 0.43 Ø Max. 2.25 0.09 1.9 0.07 2.1 0.08 2.6 0.10 2.6 [0.10] 7.5 [0.30] Part No. 1393677-2 1393677-1 1392011-4 Part No. 1393677-4 1393677-3 1392011-5 Part No. 1393677-6 3.5 [0.14] ECN1137-7 Recommended Recommended Mounting Holes Mounting Holes Ø 0.8 [0.31] Vertical PC Board Mount SMD Jack 1.27 Pitch [0.05] 5.0 [0.20] Part No. 1393757-6 2.6 [0.10] 5.0 [0.20] PC Board ECN1633-5 234 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Series MMCX (50 Ohm) (Continued) Right Angle PC Board Mount SMD Jack 0.8 [.031] 5.0 [0.20] 2.6 [0.10] 2.1 [.083] 1.6 [.063] 5.0 [0.20] 1.4 [.055] 1.4 [.055] PC Board Part No. 1393757-7 5.6 [0.22] ECN1634-D Solder Pad Conductor Layer Right Angle PC Board Mount Jack Reference Plane 6.5 [.256] Part No. 1392011-3 4.75 [.187] 2.6 [.102] 3.8 [.150] Ø 0.8 [0.31] 6.8 [.268] 1.27 Pitch [0.05] Recommended Mounting Holes Ø 0.7 [.028] 3.5 [.138] 2.8 ± 0.1 [.110 ± .004] 3.5 ± 0.1 [.138 ± .004] 3.4 ± 0.05 [.134 ± .002] Part No. 1392028-1 Ø 4.45 ± 0.05 [.175 ± .002] 7.45 ± 0.1 7.4 ± 0.1 [.293 ± .004] [.291 ± .004] 4.4 ± 0.05 [.173 ± .002] 3.5 [.138] 0.2 [.008] 4.6 [.181] 1.1 1.55 [0.43] [0.61] 4.5 [.177] Ø 0.7 ± 0.03 [.028 ± .001] Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 7.5 [.295] Dimensions are in millimeters over [inches] 0.8 [0.31] Conductor Layer Solder Pad www.amp.com/communications/com Specifications subject to change. 235 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 236 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors DIN Inserts Product Facts ■ Meets requirements of DIN 41626 and CECC 22330 ■ Suitable for DIN 41612 Type M Connectors (Eurocard), Siedecon, and Z-pack 2mm HM Connectors ■ Meets DIN Performance Level II ■ Crimp termination for inner and outer conductors (cable mount only) eliminates the need for solder ■ Right angle and vertical style board mount pin and socket contacts ■ Board mount product available with both solder and compliant tails ■ Straight cable mount pin and socket contacts for RG316, and RG179 cable ■ Contact impedance of 50 and 75 ohms for cable mount and 50 ohms for board mount Coaxial inserts according to CECC 22 330 and highcurrent inserts (CECC specification under preparation) can be used in conjunction with a DIN 41612 style M contact base (CECC 75 101-801), SIEDECON, and Z-pack 2mm HM connectors. base, by means of a “snapin” lock, make the inserts particularly well suited for applications. Coaxial inserts have a contact system based on the pin-socket principle with the same dimensions as the Series 1.0/2.3 coaxial connectors and are plug-compatible. The product family is represented by various 50Ω and 75Ω styles that can be used far into the GHz range. The high mounting density (pitch between adjacent contacts starting at 7.5 mm) and installation into the contact – coaxial jacks are installed in contact bases with AF male contacts. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Due to the centering, – coaxial plugs are installed in contact bases with audio-frequency (AF) female contacts High-current inserts with cylindrical contacts (pinsocket principle) are available with “standard” and “premating” contact design. This makes selective contacting sequences possible between high-current contacts and AF contacts; refer to “contacting range” bar diagram (page 238). This product family is based on styles featuring diverse connection possibilities for a current load up to 40 amperes. The mounting density and installation into the contact base is like that of the coaxial inserts. In this case, however, due to the alignment, you must make sure that – High-current plugs are installed in contact bases with AF male contacts – High-current sockets are installed in contact bases with AF female contacts. The high-quality materials used with coaxial and highcurrent inserts ensure a high grade of service even in an industrial atmosphere. Female contacts of refined copper beryllium assure perfect contacting. www.amp.com/communications/com Specifications subject to change. 237 Catalog 1307191 Revised 10-00 RF Coax Connectors DIN Inserts (Continued) Current rating on high current inserts as a function of component ambient temperature in accordance with DIN 41612, Part 5. Technical Data Electrical and mechanical characteristics of coaxial inserts in accordance with DIN 41626 Part 2 and CECC 22 330 Characteristic impedance 50/75 Ω Frequency range up to 2 GHz Reflection factor up to 2 GHz 1 ≤ 0.10 Insulation resistance initial value after stressing ≥ 1 GΩ ≥ 200 MΩ Screening effectiveness ≥ 70 dB Inner conductor contact resistance after stressing ≤ 10 mΩ Outer conductor continuity after stressing ≤ 7.5 mΩ Note: Styles with PC board connection for current load with 5A and 25A can also be used up to 10A and 40A if the PC boards are capable of being loaded too. Voltage proof 2 flexible cables (RG 316) – at sea level – at 20 km altitude 750 V, 50 Hz 150 V, 50 Hz Working voltage 2 flexible cables (RG 316) – at sea level – at 20 km altitude 350 V, 50 Hz 65 V, 50 Hz Service life 500 cycles Climatic category 55/125/56 Electrical and mechanical characteristics of the highcurrent inserts in accordance with DIN 41626, Part 1 238 Current load up to 40 A Contact resistance initial value after stressing ≤ 1 mΩ ≤ initial value + 1 mΩ Voltage proof 1050 V, 50 Hz Working voltage 350 V, 50 Hz Service life 500 cycles Climatic category 55/125/56 1 Guideline dimensions, depending on cable type and connector style. 2 Some cable types suitable for use with these connectors have lower characteristic values than specified here. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors DIN Inserts (Continued) Coaxial Inserts, 50 Ohm Z-PACK 2mm HM Connectors Vertical PC Board Mount, compliant 12.21 [.480] Ref. 5.50 [.216] Min. 4.15 –0.012 [.163 –.0004] 4.75 –0.03 [.187 –.001] 1.15 +0.30 [.045 +.012] 90°0' Typ. 5.10 Max. [.200] Sq. 1.00 ±0.05 Typ. [.039 ±.002] 45°0' Typ. 5.08 ±0.05 [.200 ±.002] Recommended PC Board Layout Part No. 148385-1 Right Angle PC Board Mount, compliant 17.75 Ref. [.700] 5.35 –0.30 [.216 –.012]  0.03 4.75  0.09 .001 .187   .004 4.20 +0.075 [.165 +.003] 7.00 ±0.10 [.275 ±.004] 6.10 Max. [.240] Sq. 90°0' Typ. 45°0' Typ. 4.00 ±0.10 [.157 ±.004] 50 50 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Type Vertical PCB Socket, Compliant Rt. Angle PCB Pin, Compliant Dimensions are in millimeters over [inches] 5.08 ±0.05 [.200 ±.002] Recommended PC Board Layout Part No. 148386-1 Rating (Ohms) 1.00 ±0.05 Typ. [.039 ±.002] Housing Type Z-PACK 2mm HM Male Z-PACK 2mm HM Female Application Tooling Part No. 904800-1 148385-1 904805-1 904804-1 Support Anvil 148386-1 www.amp.com/communications/com Specifications subject to change. 239 Catalog 1307191 Revised 10-00 RF Coax Connectors DIN Inserts (Continued) Coaxial Inserts to SMA Adapters Coaxial Insert Plug to SMA Plug 7.92 ± 0.12 [.312 ± .005] Hex. Ø 4.75 + 0.03 – 0.10 [.187 + .001] – .004 23.1 Max. [.910] Part No. 1274194-1 Coaxial Insert Socket to SMA Plug 7.92 ± 0.12 [.312 ± .005] Hex. Ø 4.75 + 0 – 0.02 [.187 + .000] 23.3 [.920] Max. – .001 Part No. 1274193-1 Coaxial Insert Plug to SMA Jack 7.92 ± 0.12 [.312 ± .005] Hex. 19.1 [.755] Max. Part No. 1274192-1 Coaxial Insert Socket to SMA Jack Part No. 1274191-1 240 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors DIN Inserts (Continued) Coaxial Insert to Semi Rigid Cable Terminates to 2.18 [.086] semi rigid cable Socket, Straight Cable 19.00 Ref. [.748] Ø 5.92 ± 0.03 [.233 ± .001] 4.09 ± 0.06 [.161 ± .002] Part No. 1274220-1 Plug, Straight Cable 18.75 [.738] Ref. Ø 5.92 ± 0.03 [.233 ± .001] Part No. 1274221-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 241 Catalog 1307191 Revised 10-00 RF Coax Connectors DIN Inserts (Continued) Coaxial Inserts (50 Ω/75 Ω) Ø 5.8 [.228] 4.05 [.159] 9.6 [.378] 23.9 [.941] ECN1641-V Ø 5.8 [.228] 4.75 [.187] 9.35 [.368] 23.9 [.941] Bulkhead cable jack for male connectors Ø Max. Cable Type 2.6 .102 2.67 .105 RG 316 (50 Ω) RG 179 (75 Ω) Width Across Flats of Hex Profile 3.2 .126 3.2 .126 Part No. 1392020-1 3-1393668-4 Bulkhead cable jack for female connectors RG 316 (50 Ω) Width Across Flats of Hex Profile 3.2 .126 1392019-1 RG 179 (75 Ω) –– 3-1393668-0 Ø Max. Cable Type 2.6 .102 2.67 .105 Part No. ECN1643-C Right Angle Bulkhead Jack for male connectors Ø 6.0 [.236] Dim a a 9.6 [.378] Ø 4.05 [.159] 19 .748 22.4 .882 24.0 .945 13.1 [.516] Ø Max. Cable Type 2.6 .102 2.67 .105 2.67 .105 2.67 .105 RG 316 (50 Ω ) Width Across Flats of Hex Profile Part No. 3.2 .126 1-1393668-2 RG 179 (75 Ω) 3.2 .126 3.2 .126 RG 179 (75 Ω) RG 179 (75 Ω) 2-1393668-8 3-1393668-6 Right Angle Bulkhead Plug for female connectors Ø 6.0 [.236] a 9.35 [.368] Ø 4.75 [.187] 13.1 [.516] 242 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Dim a Ø Max. Cable Type Width Across Flats of Hex Profile Part No. 18.7 .736 22.3 .878 18.7 .736 18.7 .736 2.6 .102 2.6 .102 3.0 .118 2.67 .105 RG 316 (50 Ω) –– 1393668-4 RG 316 (50 Ω) –– 1393668-8 RG 316 (50 Ω) –– 1393668-7 RG 179 (75 Ω) 3.2 .126 2-1393668-4 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors DIN Inserts (Continued) Coaxial Inserts (50 Ω/75 Ω) (Continued) 17.9 [.705] 9.35 [.368] 5.08 [.200] Ø 1.0 [.039] Ø 4.75 [.187] Bulkhead Plug, PC Board connection for DIN 41612 M female connectors Part No. 1-1393662-0 Pitch 2.54 [0.10] Recommended Mounting Hole Right Angle Bulkhead Jack, PC Board for DIN 41612 M male connectors 17.9 [.705] 3.0 [.118] 9.6 [.378] 4.05 [.159] Part No. 1-1393662-4 6.9 [.272] 5.08 [.200] ECN0400-B Right Angle Bulkhead Plug, PC Board for SIEDECON female connectors 17.8 [.701] 3.0 [.118] 9.35 [.368] Ø 4.75 [.187] Part No. 1-1393662-2 6.9 [.272] 5.08 [.200] Ø 1.0 [.039] ECN0445-B Pitch 2.54 [0.10] Mounting holes for Part No. 1-1393662-2 and 1-1393662-4 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 243 Catalog 1307191 Revised 10-00 RF Coax Connectors Size 8 Contacts Performance Characteristics Frequency Range — 0 to 500 MHz Operating Voltage, Max. — 275 vac rms @ sea level Termination Resistance, Max. — Center Contact — 6.0 milliohms Outer Contact — 3.0 milliohms Insulation Resistance, Min. — 5,000 megohms @ 500 vdc Dielectric Withstanding Voltage — Sea Level — 800 Volts rms 30,000 ft [9,144 m] — 525 volts rms 70,000 ft [21,336m] — 275 volts rms VSWR to 500MHz, Max. Pin/Socket Straight/Straight Right-Angle/Straight Right-Angle/Right-Angle VSWR 1.30 1.35 1.40 RF Crosstalk — 90dB @ 5-500 MHz Mating Force, Max. — 4.0 lb [17.8 N] Unmating Force, Min. — 2.0 oz [0.556 N] Contact Retention — 20 lb [89 N] Contact Durability — 500 cycles Cable RG/U 316, 188, 174, 179, 179A, 179B 188-type Double-Braid 142, 142A, 142B Moisture Resistance — 240 hours per MIL-STD-1344, Method 1002, Cond. II Salt Fog — 48 hours per MIL-STD1344, Method 1001, Cond. B Material Brass — per QQ-B-626 and MIL-C-50 Phosphor Bronze — per QQ-B-750 Beryllium Copper — per QQ-C-530 TEFLON—per MIL-P-19468 Nylon—per MIL-M-20693 Extraction Tool Numbers Subminiature D Housings — 58095-1 (AMPLIMITE) AMP-HDI Housings — 58095-2 Force lb [N] 20 89 Finish Bright Tin-Lead Plating — per ASTM-B-571 Copper Plating — per MIL-C-14550 Gold Plating — per MIL-G-45204 Nickel Plating — per QQ-N-290 Related Catalogs 35 155.8 50 222.5 Subminiature D Housings 82069 AMP-HDI 82618 Operating Temperature — 55°C to +125°C Thermal Shock — 55°C to +125°C per MIL-STD-1344, Method 1003, Cond. A Physical Shock — 50 G’s per MILSTD-1344, Method 2004, Cond. A Vibration — MIL-STD-1344, Method 2005, Cond. II Straight Contacts Pin Socket A Max. A Max. B Dia. Max. B Dia. Max. Alignment Ring for use in Subminiature D housing only RG/Cable Shell Type 178, 178A, 178B,196, 196A Brass 174, 316, 188, 188A 179, 179A, 179B, 187, 187A, 161, Belden 9221 174, 316, 188, Double Braid 142, 142A, 142B, 400, Belden 9246 Brass Diecast Brass Diecast Brass Diecast Brass Dimensions A B 24.13 .950 24.28 .956 24.28 .956 24.28 .956 24.28 .956 24.28 .956 24.28 .956 27.43 1.08 5.94 .234 5.94 .234 5.94 .234 5.94 .234 5.94 .234 5.94 .234 5.94 .234 6.48 .255 50 ohm Non-Impedance Matched Pin Socket Die Insert* Pin Socket 59993-1 — — 228616-5 228596-5 59993-1 221980-1 221981-1 228618-1 228596-1 59993-1 415367-1 415366-1 415369-1 415368-1 59993-1 221980-3 221981-3 228618-2 228596-2 59993-1 — — 415369-3 415368-3 59993-1 — — 228618-3 228596-3 59993-1 415367-2 415366-2 415369-2 415368-2 58212-1 221980-2 221981-2 228618-4 228596-4 *For hand tool 69710-1 or pneumatic tool 69365-8. Note: Non-Impedance Matched and 50 Ohm are not intermateable. 244 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Size 8 Contacts (Continued) PC Board Mount Contacts (for AMP-HDI Connectors only) Vertical Pin Contact Right Angle Socket Contact 5.69 [.224] 6.50 [.256] 17.58 [.692] 9.25 [.364] 11.33 [.446] 16.23 [.639] ±0.08 Dia. ±.003] 1.02 [.040 (5 Holes) 5.08 ±0.08 [.200 ±.003] 2.54 ±0.08 [.100 ±.003] 5.08 ±0.08 [.200 ±.003] 2.54 ±0.08 [.100 ±.003] Recommended PC Board Layout Type Vertical Pin Contact Right Angle Socket Contact Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Contact Part No. Non-Impedance 50 Ohm Matched 221158-1 222016-1 221162-1 222015-1 www.amp.com/communications/com Specifications subject to change. 245 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 246 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Coaxial Contacts (COAXICON) Product Facts ■ AMP provides a variety of contacts for coaxial connectors ■ Contacts are available in a range of sizes that may be used with the various types of coaxial cable on the market ■ COAXICON contacts are of the crimp, snap-in type and are available in the following designs: Miniature Contacts, Subminiature Contacts and Size 8 Contacts Miniature Contacts are designed for high density multiple circuit connector applications. A wide range of cable sizes is accommodated by using three sizes of outer shell termination ends and three sizes of contacts. Subminiature Contacts are used in high density applications and are ideal for mixing coaxial and other styles of pin and socket contacts in the same connector housing. Size 8 Contacts are compatible with industry standard size 8 connectors such as Subminiature D (AMPLIMITE) and AMP-HDI connector housings. Straight and right-angle styles, as well as pc board versions for AMP-HDI connectors are available. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 247 Catalog 1307191 Revised 10-00 RF Coax Connectors Miniature Contacts Performance Characteristics Insulation Resistance — 5000 megohms min Dielectric Withstanding Voltage — 1,000 volts rms for 1 minute Contact Resistance — 2.0 milliohms @ 1 ampere Low-Level Conductivity — 10 millivolts DC min. VSWR — 1.3 to 1.0 @ 1,000 MHz max. Cable Retention — RG/U Cable 58C 188A 180B 195A Retention lbs [N] 50 [222] 30 [133] 28 [125] 16 [71] Temperature Range — -55°C to +125°C Test Method for Electronic and Electrical Component Parts — MIL-STD-202 Inner Dielectric — Polypropylene, nylon, or polymethylpentene, general purpose Retention Spring — Stainless steel per QQ-S-766 Ferrule — Copper per QQ-C-576 Material Finish Outer Shell, Center Conductor — 0.00076 [.000030] gold over 0.00076 [.000030] nickel Retention Spring — Nickel per QQ-N-290 Ferrule — Bright tin-lead per MIL-T-10727 Outer Shell — Brass per MIL-C-50 Center Conductor — Brass per QQ-B-626, or Beryllium copper per QQ-C-533 Retention Springs Part No. 201142-2 Note: A ferrule and retention spring (201142-2) are required for each pin and socket. Extraction Tool No. 305183-8 Durability — 500 cycles @ 10 cycles per minute max. Vibration — 2 hrs. per MIL-STD-202, Method 201 Shock — 50 G’s per MIL-Std-202, Method 213, Cond. G Temperature Cycling — 5 cycles per MIL-STD-202, Method 102, Cond C. Ferrules Socket Pin RG/U Cable Ferrule No. Integral Die Hand Tool Die Insert for Tools: Hand Tool 69710-1 Pneu. 69365-2, 69365-33 178, 178A, 178B* 196, 196A 316, 188, 188A* 174 179, 179A, 179B 161, 187, 187A* Belden 9221 188 Double Braid* 316 Double Braid 122* 180, 180A, 180B 195, 195A,** 21-597 Belden 8218** 58, 58A, 58B, 58C** 141** 55, 55A, 55B, 223 124, 140, 210 62, 62A, 62B 59, 59A, 59B *328667 69186-2 69373 201511-1 201512-1 *328666 45638-2 69227-2 201143-5 201144-5 *328666 45638-2 69227-2 201143-1 201144-1 221848-3 58290-1 69227-2 201143-5 201144-5 328664 45639-2 69222-2 201145-1 — 328664 45639-2 69222-2 201145-2 201146-2 328664 328663 45639-2 45740-2 69222-2 69220-2 201145-2 201145-4 201146-2 201146-4 330478 69248-4 69315-4 201145-4 201146-4 329006 — 69675-1 201097-1* 201098-1* 328667 69186-2 69373 201511-1-2 201512-1 328666 45638-3 69672 201143-5* 201144-5 69220-2 201145-4* 201146-4 69222-2 201145-2* 201146-2 Pin Part Numbers Socket Twisted Pair 28-26 AWG [0.08-0.15 mm2]** (Solid)1 24-22 AWG [0.2-0.4 mm2]* (Stranded)2 Shielded Wire* 22, NAS-702, Class B Brand Rex T5788A* 26 AWG [0.12-0.155 mm2]4 328663 328664 45740-2 45639-2 *These contacts are for use in the 4-position G Series connector modules only. 1 Maximum insulation diameter–2.03 [.080] (two wires combined). 2 Maximum insulation diameter–2.92 [.115] (two wires combined). 3 Includes bench mount and foot control; requires Manual Take-Up Attachment No. 69689. 4 Dielectric O.D.–2.69 [.106] max.; Cable O.D.–4.06 [.160]. 248 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Miniature PC Board Sockets Material Shell and Center Contact — Brass per MIL-C-50 and QQ-B-626 Dielectric — Polypropylene, or Polymethylpentene, general purpose Shell Finish Spring Latch Center Contact — 0.00076 [.000030] gold over copper Shell — Gold plated per MIL-G-45204 Performance Characteristics Dielectric Withstanding Voltage — 1,000 volts, rms Impedance — Non-constant Operating Temperature Range — -55°C to +85°C 2.54 [.100] 2.54 [.100] Locking Latch Center Conductor 15.24 [.600] 12.7 [.500] Spring Latch Locking Latch 2.54 Ref. [.100] 2.54 Ref. [.100] 6.23 [.245] 4.52 Dia. [.178] Ref. 1.32 [.052] Dia. (5 Holes) A 0.36 Ref. [.014] Recommended Mounting Hole Layout B 1.27 Typ. [.050] PC Board Thickness Type Spring Latch Spring Latch Locking Latch Locking Latch 1.57 .062 3.18 .125 3.18 .125 1.57 .062 12.7 [.500] 2.54 [.100] 17.78 [.700] Retention lb. [N] 1.25 5.56 1.25 5.56 7.25 31.16 7.25 31.16 1.02 Dia. [.040] Dimensions A B 9.07 3.18 .357 .125 7.49 4.75 .295 .187 7.49 4.75 .295 .187 9.07 3.18 .357 .125 Part No. 50084-1 50095-1 50105-1 50107-1 Note: For mateable Miniature Contacts, see page 248. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 249 Catalog 1307191 Revised 10-00 RF Coax Connectors Subminiature PC Board Sockets Material Shell and Center Contact — Brass per MIL-C-50 and QQ-B-626 Dielectric — Polypropylene, or polymethylpentene, general purpose Shell Locking Latch Finish Center Contact — 0.00076[.000030] gold per MIL-G-45204 over copper per MIL-C-14550 Shell — Gold Performance Characteristics Spring Latch Center Conductor Dielectric Withstanding Voltage — 600 volts, rms Operating Temperature Range — -55°C to +85°C 1.09 Dia. [.043] #57 Drill (3 Holes) 22.23 Max. [.875] 3.05 ±.0.2 [.120 ±.008] 4.52 [.178] 1.47 [.058] Locking Latch A 0.84±0.2 [.033±.008] 10.16 [.400] 0.84 Dia. [.033] 10.16 [.400] 15.24 [.600] 15.24 [.600] Recommended Mounting Hole Layout PC Board Thickness 1.57 .062 1.57 .062 Type Spring Latch Locking Latch Dim. L 2.54 .100 2.54 .100 Part No. 226023-1 226060-1 Mating Subminiature COAXICON Pins These short Subminiature COAXICON Pins are recommended for use with any of the sockets listed above. Note: Alignment springs are not required for this application and are not included with the pin assemblies. 250 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 RG/U Cable Ferrule No. Integral Die Hand Tool Die Insert for Tools: Hand Tool 69710-1 Pneu. 69365-2, 69365-3 Part No. 178, 178A, 178B 196, 196A 174 316, 188, 188A 179, 179A, 179B 187, 187A 161 1-332057-0 69656-2 69690-2 51563-9 1-332056-0 69656-2 69690- 51563-8 1-332056-0 69656-1 69690-1 51563-8 1-332056-0 69656-5 — 51563-8 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Subminiature Contacts Material Outer Shell — Brass per MIL-C-50 Center Conductor — Beryllium copper per QQ-C-533 (Pin); Brass per QQ-B-626 (Socket) Inner Dielectric — Polypropylene, nylon, or polymethylpentene, general purpose Retention Spring — Stainless steel per QQ-S-766 Ferrule — Copper per QQ-C-576 Ferrule A Ferrule Finish Outer Shell and Socket Center Conductor — 0.00076 [.000030] gold over 0.00127 [.000050] nickel Pin Center Conductor — 0.00076 [.000030] gold over 0.00254 [.000100] copper Ferrule — Bright tin-lead per MIL-T-10727 16.51 Max. [.650] Pin Socket A = Multimate Pin 25.65 [1.010] Short Pin 22.66 [.892] Selection Chart for Coaxial Cable RG/U Cable 178, 178A, 178B 196, 196A 196 (Double Braid) 174, 316 188, 188A 179, 179A, 179B 187, 187A Belden 9221 RD-316 187 (Double Braid) 161 Integral Die Hand Tool Die Insert for Tools: Hand Tool 69710-1 Pneu. Tool 69365-2, 69365-3* Multimate Pin 69656-2 69690-2 226537-2 51563-2 51565-2 1-332057-0 69656-9 — 226537-2 51563-2 51565-2 1-225088-1 69656-2 69690 -226537-1 51563-1 51565-1 1-332056-02 69656-1 69690-1 226537-1 51563-1 51565-1 1-332056-0 69656-7 — 226537-1 51563-1 51565-1 1-225088-3 69656-8 — 226537-1 51563-1 51565-1 1-225088-1 69656-5 — 226537-1 51563-1 51565-1 1-332056-0 Contact Part Numbers Short Socket Pin Ferrule Selection Chart for Twisted Pairs and Shielded Wire Wire Size Die Insert for Tools: Hand Tool 69710-1 Pneu. Tool 69365-2, 69365-3* Multimate Pin 69690-2 226537-3 51563-3 51565-3 1-332057-0 Contact Part Numbers Short Socket Ferrule Pin AWG [mm ] IntegralDie Hand Tool 30 (Twisted Pair, Solid) 28 (Twisted Pair, Solid) 28 (Twisted Pair, Stranded; 7 str., .005 [0.13] Dia.) 26 (Twisted Pair, Solid or Stranded; 7 str., .0063 [0.16] Dia.) 26 (Shielded, 0.75 [1.91] Max. O.D.) 0.05 69656-2 0.08-0.09 69656-2 69690- 226537-3 51563-3 51565-3 1-332057-02 0.08-0.09 69656-1 or 69656-2 69690-1 or 69690-2 226537-3 51563-3 51565-3 1-332057-0 0.12-0.15 69656-2 69690-2 226537-3 51563-3 51565-3 1-332057-0 0.12-0.15 69656-3 69690-3 226537-1 51563-1 51565-1 1-332057-0 2 *Includes bench mount and foot control. Extraction Tool 305183 Note: A ferrule is required for each pin and socket. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 251 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 252 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Siemax Connectors Applications ■ Multiplex Systems ■ Base Stations ■ High Density Systems Features ■ Multi Coax Surface Mount ■ Maximum packaging density ■ Component placement on both sides of PCB ■ Fully automated assembly (pick-and-place) ■ Modular design Technical Data ■ Interface: Series 1.0/2.3 ■ Impedance: 75 ■ International specifications: IEC 169-29 and CECC 22 230 ■ Frequency range up to 2 Ghz ■ Compact grid pitch 10 [0.39] ■ Guaranteed coplanarity of max. 0.1 [0.004] ■ Integrated positioning pins for manual placement ■ Optional mechanical securing EC98062 Siemax connectors combine the benefits of surface mount technology and modular design. This multi coax connector is packaged in tape-and-reel for automatic placement, has optimum solder joints and 100% reflow suitability. This con- nector is ideal for systems requiring superior packaging density because it can be placed on both sides of the printed circuit board. The modular design provides flexibility in terms of the number of poles offered (two-, three-, or four-poles). It can be stacked, enabling any required configuration to be produced. The Siemax connector also allows the use of any other connector series, e.g. SMB, is resistant to high temperatures, and is robust, with reliably sustained coplanarity. For General Information on Series 1.0/2.3 Connectors, see Page 125. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 253 Catalog 1307191 Revised 10-00 RF Coax Connectors Siemax Connectors, Series 1.0/2.3 (75 Ohm) Siemax, SMT Right Angle Jack, 2 Poles 18.0 [0.71] 24.0 [0.94] Ø 4.15 [0.16] 14.0 [0.55] 2.0 [0.08] 8.0 [0.31] 10.0 [0.39] Ø 1.4 [0.06] 2.0 [0.08] 1.2 [0.05] 12.1 [0.48] 11.1 [0.44] 6.5 [0.26] Coupling type C, F Ø 2.6 [0.10] 1.6 [0.06] 13.0 [0.51] Part No. 1393696-2 1.9 [0.07] 17.5 [0.69] Solder Pad layout Siemax, SMT Right Angle Jack, 3 Poles 28.0 [1.10] 24.0 [0.94] Ø 4.15 [0.16] 10.0 [0.39] 6.5 [0.26] 3.5 [0.14] Coupling type C, F 24.0 [0.94] 2.0 [0.08] Part No. 1393696-7 10.0 [0.39] 8.0 [0.31] Ø 1.4 [0.06] 2.0 [0.08] 1.2 [0.05] Ø 2.6 [0.10] 12.1 [0.48] 11.1 [0.44] 1.6 [0.06] 10.0 [0.39] 23.0 [0.91] 1.9 [0.07] 27.5 [1.08] Solder Pad layout Siemax, SMT Right Angle Jack, 4 Poles Ø 4.15 [0.16] 28.9 [1.14] 18.4 [0.72] 20.5 [0.81] 15.2 [0.60] 3.5 [0.14] 4.0 [0.16] 9.0 [0.35] Ø 2.4 [0.09 14.3 [0.56] 7.95 [0.31] 1.2 [0.05] 2.6 [0.10] 12.0 [0.47] Coupling type C, F Part No. 1393696-3 20.5 [0.79] 11.3 [0.44] Solder Pad layout Note: 2 and 3 poles Series SMB in development 254 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters Between Series Coaxial Transmission Line Adapters provide convenient transitions between popular series coaxial connectors. The adapter design provides a minimum length consistent with good electrical performance. The small size, low VSWR, and broad frequency coverage permits a wide range of applications in both measurement and systems use. Design and Construction Types The standard units are constructed of stainless steel with passivated finish, nickel plated brass, and gold plated brass. The material and plating is to be consistent with the basic connector series. All dielectrics are TFE fluorocarbon. The center contacts are made of beryllium copper, gold plated. The straight in-line adapters are available in many combinations of plug and jack (male and female) configurations. Also, popular panel mount versions are cataloged. For special modifications and hermetic seal version, consult AMP. Application The major application is the requirement for a low VSWR, compact transition in both test system and operating systems. Many panel mount and bulkhead mount versions are available so the designer can use small size connectors for internal design, but adapt to a larger rugged version for external connection. Selection charts follow to help you find the correct adapter for your application. Plug-Plug SSMT OSMT Page 257 Page 257 Page 257 SSMT OSMT Series 1.0/2.3 Series 1.0/2.3 OSMP SMA SMB 7-16 TNC BNC OSP Bulkhead OSP N Series Page 257 Page 257 Page 257 Page 257 Page 257 Page 257 MCX N Series N Series Flange Mount N Series Bulkhead OSP OSP Bulkhead OSP Floating Rear Mount MCX N Series BNC TNC Series 1.6/5.6 SMA 18 GHz Page 257 Page 257 Page 257 Page 257 Page 257 Page 257 Jack-Jack Series 1.6/5.6 OSMP SMB 75 OHM SMB 7-16 TNC TNC Flange Mount TNC Bulkhead BNC BNC Bulkhead N Series BNC TNC SMA SMA Bulkhead SMA 18 GHz Series 1.0/2.3 Page 258 Page 258 Page 258 Page 258 Page 258 and 259 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Page 260 Page 258 Page 259 and 260 Page 258 Page 258 and 259 Page 259 Page 259 Page 259 Page 259 Page 260 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 255 Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters (Continued) Jack-Plug DIN-Series 1.6/5.6 DIN-Series 1.0/2.3 SSMT + OSMT OSMP Page 260 Page 260 SMA SMA Flange Mount SMA 18 GHz SMB 7-16 TNC BNC 256 OSP OSP Bulkhead Page 260 Page 260 Page 260 Page 260 Page 260 N Series Page 260 Page 261 N Series Flange Mount OSP Page 261 OSP Bulkhead BNC TNC TNC Flange Mount Page 262 Page 262 7-16 SMB 75 OHM SMB SMA SMA Flange Mount SMA 18 GHz OSMP SSMT + OSMT DIN-Series 1.0/2.3 DIN-Series 1.6/5.6 N Series N Series Flange Mount MCX 7 mm best VSWR 7 mm 7 mm 7 mm best VSWR MCX Page 263 Page 261 Page 261 Page 261 Page 261 Page 261 Page 261 Page 262 Page 262 Page 262 Page 262 Page 262 Page 262 Page 262 Page 263 Page 264 Page 262 Page 263 Page 263 Page 263 Page 264 Page 263 Page 263 and 264 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Page 263 Page 263 Page 263 Page 264 Page 264 Page 264 Page 264 Dimensions are in millimeters over [inches] Page 264 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters (Continued) Plug-Plug MCX Plug – SMA Plug 7-16 Plug – N Series Plug 19.3 [.760] Ref. 6.4 Hex. [.250] BNC Plug – SMB Plug 48.6 Ref. [1.912] Ø 14.3 Ref. [.562] 34.1 [1.343] Ref. Ø 32.0 Ref. [1.260] 7.9 Hex. [.312] Part No. 1061071-1 M/A-COM Model No. 5881-2241-00 Part No. 1313453-1 M/A-COM Model No. A55P23E999X Part No. 1058066-1 M/A-COM Model No. 3281-2223-00 TNC Plug – BNC Plug SMA 18 GHz Plug – N Series Plug SMA Plug – BNC Plug 32.5 [1.281] Ref. 49.6 Ref. [1.953] Ø 15.9 Ref. [.625] 32.9 Ref. [1.297] 7.9 Hex. [.312] Ø 21.0 Ref. [.828] 7.9 Hex. [.312] Ø 14.3 Ref. [.562] Part No. 1057851-1 M/A-COM Model No. 3181-2321-00 Part No. 1057367-1 M/A-COM Model No. 3081-2241-00 Part No. 1058067-1 M/A-COM Model No. 3281-2241-00 SMA Plug – TNC Plug SMA Plug – SMB Plug SMA Plug – OSMP Plug 21.9 [.862] Ref. 26.4 Ref. [1.040] 7.9 Hex. [.312] Ø 15.9 Ref. [.625] 17.5 Ref. [.690] 6.4 Hex. [.250] 7.9 Hex. [.312] Part No. 1057849-1 M/A-COM Model No. 3181-2241-00 Part No. 1060494-1 M/A-COM Model No. 5181-2241-00 Part No. 1056706-1 M/A-COM Model No. 2981-2241-00 SMA Plug – SSMT Plug or OSMT Plug SMA Plug – OSP Plug SMA Plug – OSP Bulkhead Plug 22.7 Ref. [.895] 17.0 [.670] Ref. 13.7 Ref. [.538] 1.7 [.065] Part No. 1055695-1 M/A-COM Model No. 2381-2241-00 Part No. 1059711-1 M/A-COM Model No. 4581-2241-02 Series 1.6/5.6 Plug – Series 1.0/2.3 Plug BNC Plug – Series 1.6/5.6 Plug 9.2 [0.36] Ø 6.5 [0.26] 1) 28.0 [1.10] 1) 8.9 [0.35] Part No. 2-1393670-1 Coupling Type A Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 .003 Ø 6.15 +– .000 + .001 [.242 – .000 ] 7.9 [.312] Hex. 7.9 Hex. [.312] 11.1 Hex. [.437] 7.9 Hex. [.312] Ø 10.8 [0.43] 11.4 [.447] 3.2 [.125] Max. Panel Recommended Mounting Hole Part No. 1059726-1 M/A-COM Model No. 4583-2241-02 Ø 14.5 [0.57] 46.4 [1.83] Part No. 1-1393665-4 Dimensions are in millimeters over [inches] Ø 10.8 [0.43] 1) Detent for jack www.amp.com/communications/com Specifications subject to change. 257 Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters (Continued) Jack-Jack 7-16 Jack – N Series Jack BNC Jack – SMB Jack BNC Jack – 75 ohm SMB Jack 30.4 [1.197] 51.0 [2.010] 12.9 [.508] 32.1 [1.265] Ref. Ø 14.3 Ref. [.562] 3.82 [.150] 17.4 Hex. [.687] 12.0 Across [.472] Flat Ø 12.9 [.508] 15.8 Hex. [.625] Part No. 1311206-1 M/A-COM Model No. A55P22E999X Part No. 1058056-1 M/A-COM Model No. 3280-2224-00 Part No. 1311209-1 M/A-COM Model No. A57R03G999X TNC Jack – N Series Flange Mount Jack TNC Jack – BNC Jack MCX Jack – SMA Jack 49.1 Ref. [1.932] 2.0 [.080] 16.7 [.656] 43.1 Ref. [1.698] 25.4 Sq. [1.00] 15.6 [.615] 6.4 Hex. [.250] Ø 14.5 Ref. [.572] Ø 3.2 4 Plcs. [.125] 18.2 Typ. [.718] Part No. 1057843-1 M/A-COM Model No. 3180-2302-00 Part No. 1057845-1 M/A-COM Model No. 3180-2320-00 Part No. 1061070-1 M/A-COM Model No. 5880-2240-00 SMA Jack – N Series Jack SMA Jack – N Series Flange Mount SMA Jack – N Series Bulkhead Jack 31.3 [1.232] 18.2 [.718] 31.3 [1.231] 31.3 [1.231] 25.4 Sq. [1.00] Ø 17.45 Ref. [.687] 4.7 Max. [.187] Panel Ø 3.2 4 Plcs. [.125] 6.3 Max. [.250] Panel 3.2 [.125] Ø 22.0 [.866] 22.0 [.867] 13.6 [.534] Min. Ø 15.9 Min. [.625] Recommended Mounting Hole Part No. 1057341-1 M/A-COM Model No. 3080-2240-00 Part No. 1057343-1 M/A-COM Model No. 3080-2242-00 Part No. 1057463-1 M/A-COM Model No. 3084-2240-00 SMA Jack – BNC Jack BNC Bulkhead Jack – SMA Jack TNC Jack – SMA Jack 33.5 [1.320] Ref. Ø 14.3 Ref. [.562] 33.5 [1.320] 17.9 [.703] 5.6 [.220] Min. 3.2 Max. [.125] Panel Ø 12.7 Min. [.500] 25.4 Ref. [1.000] Ø 13.5 Ref. [.531] 15.9 Hex. [.625] Part No. 1058058-1 M/A-COM Model No. 3280-2240-00 258 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 17.4 Hex. [.687] Recommended Mounting Hole Part No. 1058117-1 M/A-COM Model No. 3284-2240-00 Dimensions are in millimeters over [inches] Part No. 1057839-1 M/A-COM Model No. 3284-2240-00 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters (Continued) Jack-Jack (Continued) TNC Flange Mount Jack – SMA Jack 25.4 [1.000] 2.4 [.093] 8.0 [.315] SMA Jack – TNC Bulkhead Jack SMB Jack – SMA Jack 33.0 [1.300] 17.4 Sq. [.687] 12.7 Typ. [.500] Ø 11.1 [.437] 4.8 [.188] Max. Panel 6.4 Max. [.250] Panel 17.8 [.700] 5.0 Min. [.196] 3.2 [.125] Ø 11.2 Min. [.439] 6.4 Hex. [.250] Ø 16.7 [.656] 14.3 Hex. [.562] Recommended Mounting Hole Part No. 1057841-1 M/A-COM Model No. 3180-2242-00 Part No. 1057908-1 M/A-COM Model No. 3184-2240-00 SMA Jack – OSMP Jack SMA Jack – SSMT or OSMT Jack Part No. 1060487-1 M/A-COM Model No. 5180-2240-00 OSP Jack – SMA Bulkhead Jack 17.3 [.680] 3.2 Max. [.125] Panel 12.6 [.498] 0.03 Ø 6.15 +– 0.00 + .001 [.242 – .000 ] 5.8 [.230] 12.9 [.508] Ref. 4.70 [.187] 7.9 Hex. [.312] Part No. 1056702-1 M/A-COM Model No. 2980-2240-00 Part No. 1055694-1 M/A-COM Model No. 2380-2240-00 SMA 18 GHz Jack – N Series Jack SMA 18 GHz Jack – N Series Flange Mount Jack 31.2 [1.229] Ref. Recommended Mounting Hole 7.9 Hex. [.312] Part No. 1059733-1 M/A-COM Model No. 4584-2244-02 SMA 18 GHz Jack – N Series Bulkhead 31.3 [1.232] 31.2 [1.229] Ref. Ø 3.2 4 Plcs. [.125] 16.5 [.650] 18.2 [.718] Typ. 2.0 [.080] 22.0 [.867] 6.3 Max. [.250] Panel 13.6 [.534] Min. 3.2 [.125] Ø 15.9 Min. [.625] Ø 17.4 Ref. [.687] 4.7 Max. [.187] Panel Ø 16.0 [.630] Max. 25.4 Sq. [1.000] Part No. 1058651-1 M/A-COM Model No. 3680-2240-00 Part No. 1058653-1 M/A-COM Model No. 3680-2242-00 OSP Jack – SMA Jack SMA Jack – OSP Bulkhead Jack 11.1 Hex. [.437] 11.1 Hex. [.437] 14.1 [.554] Ø 7.6 [.300] Part No. 1059707-1 M/A-COM Model No. 4580-2240-02 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 3.2 Max. [.125] Panel 6.4 [.250] 14.1 Ref. [.554] OSP Floating Flange Mount Jack – SMA Jack 22.2 [.874] 1.7 Ø 9.4 [.372] [.065] 14.2 [.560] 0.03 Ø 9.6 +– 0.05 Ø 2.6 + .002 [.377 – .001 ] [.102] 2 Plcs. 14.2 [.560] Ø 19.1 [.750] 3.2 Max. [.125] Panel Part No. 1059729-1 M/A-COM Model No. 4584-2240-02 Dimensions are in millimeters over [inches] Part No. 1058675-1 M/A-COM Model No. 3684-2240-00 .003 Ø 9.12 +– .000 + .001 [.359 – .000 ] Recommended Mounting Hole Recommended Mounting Hole Ø 22.0 [.866] 9.7 [.380] Recommended Mounting Hole Part No. 1059731-1 M/A-COM Model No. 4584-2242-02 www.amp.com/communications/com Specifications subject to change. 259 Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters (Continued) Jack-Jack (Continued) SMA Jack – OSP Floating Rear Mount Jack BNC Jack – Series 1.6/5.6 Jack Series 1.0/2.3 Jack – Series 1.6/5.6 Jack .050 Ø 8.0 +– .000 + .002 [.316 – .000 ] Ø 7.6 [.300] Ø 9.6 [0.38] 11.2 ± .076 [.440 ± .003] Ø 8.2 [0.32] Ø 8.2 [0.32] Ø 4.1 [0.16] Ø 14.5 [0.57] 22.2 [.874] .000 1.3 +– .127 .076 Ø 8.6 +– .000 + .003 [.340 – .000 ] + .000 [.050 – .005 ] Ø 11.0 [0.43] 39.4 [1.55] M9.0x0.5 [0.35]x[0.02] 45.4 [1.79] Ø 10.8 [0.43] Recommended Mounting Hole Part No. 1059724-1 M/A-COM Model No. 4583-2240-02 Part No. 1-1393665-5 Part No. 2-1393670-4 Coupling Type A, B, F OSP Plug to 7 mm Jack TNC Plug to 7 mm Jack Jack-Plug N Series Plug to 7 mm Jack 19.1 Hex. [.750] Ø 22.4 Ref. [.880] 19.1 Hex. [.750] 11.1 Hex. [.437] 19.1 Hex. [.750] Ø 22.4 Ref. [.880] Ø 22.1 [.870] 43.3 Ref. [1.705] 40.9 Ref. [1.610] Part No. 1061742-1 M/A-COM Model No. 7081-5008-00 Part No. 1059413-1 M/A-COM Model No. 4581-2700-00 Part No. 1061739-1 M/A-COM Model No. 7081-2311-00 SMA Flange Mount Plug to 7 mm Jack SMA Plug to 7 mm Jack N Series Plug to 7 mm Best VSWR Jack Ø 3.2 4 Plcs. [.125] 19.1 [.750] Typ. 7.9 Hex. [.312] 19.1 Hex. Ø 22.4 Ref. [.750] [.880] 2.1 [.083] 25.4 Sq. [1.000] 2.4 Max. [.093] Panel 35.0 [1.380] Ref. 19.1 Hex. [.750] 7.9 Hex. [.312] Ø 22.4 Ref. [.880] 31.8 [1.25] Ref. 19.1 Hex. [.750] Ø 22.4 Ref. [.880] 43.3 Ref. [1.705] Part No. 1061751-1 M/A-COM Model No. 7082-2243-00 Part No. 1053646-1 M/A-COM Model No. 2081-2700-00 Part No. 1061738-1 M/A-COM Model No. 7081-2301-00 TNC Plug to 7 mm Best VSWR Jack MCX Jack – SMA Plug N Series Jack – 7 mm Plug 19.1 Hex. [.750] 15.9 Hex. [.625] Ø 22.4 Ref. [.880] 40.9 Ref. [1.610] Part No. 1061744-1 M/A-COM Model No. 7081-5009-00 260 15.9 Hex. [.625] 30.7 [1.208] Ref. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 19.1 Hex. [.750] 16.8 [.660] Ref. 6.4 Hex. [.250] 36.7 [1.445] Ref. 7.9 Hex. [.312] Part No. 1061073-1 M/A-COM Model No. 5882-2241-00 Dimensions are in millimeters over [inches] Ø 22.4 Ref. [.880] Part No. 1061757-1 M/A-COM Model No. 7082-5001-00 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters (Continued) Jack-Plug (Continued) N Series Jack – 7 mm Best VSWR Plug 19.1 Hex. [.750] BNC Plug – N Series Jack Ø 22.4 Ref. [.880] N Series Jack – TNC Plug Ø 16.8 Ref. [.660] 36.7 [1.445] Ref. 51.9 Ref. [2.043] Ø 16.8 Ref. [.660] 52.7 Ref. [2.076] Ø 15.9 Ref. [.625] Part No. 1061752-1 M/A-COM Model No. 7082-2300-00 Part No. 1057392-1 M/A-COM Model No. 3082-2321-00 Part No. 1057388-1 M/A-COM Model No. 3082-2311-00 7-16 Plug – N Series Jack SMA Plug – N Series Jack SMA 18 GHz Plug – N Series Jack 32.8 [1.292] Max. 48.0 [1.890] Ref. Ø 32.0 Ref. [1.260] 32.3 [1.270] Ref. 7.9 Hex. [.312] Ø 17.4 Ref. [.687] 7.9 Hex. Ø 17.45 Ref. [.687] [.312] Part No. 1311205-1 M/A-COM Model No. A55P21E999X Part No. 1057381-1 M/A-COM Model No. 3082-2241-00 Part No. 1058664-1 M/A-COM Model No. 3682-2241-00 SMA Plug – N Series Flange Mount Jack SMA 18 GHz Plug – N Series Flange Mount Jack OSP Jack – 7 mm Plug 32.3 [1.270] Ref. 32.3 [1.270] Ref. Ø 3.2 4 Plcs. [.125] 7.9 Hex. [.312] 4.7 Max. [.187] Panel 25.4 Sq. [1.000] Ø 22.4 Ref. [.880] 18.2 [.718] Typ. 2.0 [.080] 18.2 [.718] Typ. 29.6 [1.166] Ref. Ø 3.2 4 Plcs. [.125] 15.2 [.600] 11.1 Hex. [.437] 4.7 Max. [.187] Panel Ø 16.0 [.630] Max. 19.1 Hex. [.750] 25.4 Sq. [1.000] Part No. 1057385-1 M/A-COM Model No. 3082-2243-00 Part No. 1058667-1 M/A-COM Model No. 3682-2243-00 Part No. 1059720-1 M/A-COM Model No. 4582-2700-00 SMA Plug – OSP Jack SMA Plug – OSP Bulkhead Jack BNC Jack – N Series Plug 17.4 [.685] Ref. 17.4 [.686] Ref. Ø 7.6 [.300] 6.4 [.250] Ø 9.12 3.2 Max. [.125] Panel [.359 7.9 Hex. [.312] 7.9 Hex. [.312] Part No. 1059718-1 M/A-COM Model No. 4582-2241-02 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 11.1 Hex. [.437] 49.1 Ref. [1.934] Ø 21.0 Ref. [.827] Recommended Mounting Hole Part No. 1059758-1 M/A-COM Model No. 4585-2241-02 Dimensions are in millimeters over [inches] + 0.03 – 0.00 + .001 – .000 ] Part No. 1057390-1 M/A-COM Model No. 3082-2320-00 www.amp.com/communications/com Specifications subject to change. 261 Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters (Continued) Jack-Plug (Continued) BNC Jack – TNC Plug 45.9 Ref. [1.809] BNC Jack – SMB Plug SMA Plug – BNC Jack 34.6 Ref. [1.362] 35.8 [1.408] Ref. Ø 15.9 Ref. [.625] Ø 14.3 Ref. [.562] 7.9 Hex. [.312] Ø 14.3 Ref. [.562] Part No. 1057858-1 M/A-COM Model No. 3182-2320-00 Part No. 1058077-1 M/A-COM Model No. 3282-2223-00 Part No. 1058083-1 M/A-COM Model No. 3282-2241-00 TNC Jack – 7 mm Plug TNC Jack – 7 mm Best VSWR Plug TNC Jack – N Series Plug 19.1 Hex. [.750] Ø 22.4 Ref. [.880] 19.1 Hex. [.750] Ø 22.4 Ref. [.880] 49.1 Ref. [1.934] 41.3 [1.625] Ref. 41.3 [1.625] Ref. Ø 21.0 Ref. [.827] Part No. 1061753-1 M/A-COM Model No. 7082-2310-00 Part No. 1061758-1 M/A-COM Model No. 7082-5005-00 Part No. 1057387-1 M/A-COM Model No. 3182-2310-00 TNC Jack – BNC Plug TNC Jack – SMA Plug TNC Flange Mount Jack – SMA Plug 46.7 Ref. [1.840] 26.4 Ref. [1.038] Ø 14.3 Ref. [.562] 26.4 Ref. [1.038] 2.0 [.080] 17.4 Sq. [.687] 12.7 Typ. [.500] 13.4 Ref. [.529] Ø 13.5 Ref. [.531] 7.9 Hex. [.312] Ø 11.8 Max. [.465] 7.9 Hex. [.312] Part No. 1057860-1 M/A-COM Model No. 3182-2321-00 Part No. 1057855-1 M/A-COM Model No. 3182-2241-00 Part No. 1057857-1 M/A-COM Model No. 3182-2243-00 7-16 Jack – N Series Plug SMB Jack – BNC Plug 75 Ohm SMB Jack – BNC Plug 51.9 Ref. [2.043] 30.6 [1.205] Ref. Ø 14.3 Ref. [.562] 21.9 Ref. [.863] Ø 14.3 Ref. [.562] Part No. 1312078-1 M/A-COM Model No. A55P24E999X 262 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 1058079-1 M/A-COM Model No. 3282-2224-00 Dimensions are in millimeters over [inches] Part No. 1311208-1 M/A-COM Model No. A57P01T999X www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters (Continued) Jack-Plug (Continued) SMA Plug – SMB Jack SMA Jack – MCX Plug 20.7 [.815] Ref. 31.5 [1.250] Ref. 18.2 [.716] 6.4 Hex. [.250] 6.4 Hex. [.250] 7.9 Hex. [.312] SMA Jack – N Series Plug Ø 21.0 Ref. [.828] Part No. 1060500-1 M/A-COM Model No. 5182-2241-00 Part No. 1061072-1 M/A-COM Model No. 5882-2240-00 Part No. 1057377-1 M/A-COM Model No. 3082-2240-00 N Series Flange Mount Plug – SMA Jack SMA Jack – BNC Plug TNC Plug – SMA Jack Ø 3.2 4 Plcs. [.125] 6.4 Max. [.250] Panel 31.8 [1.250] Ref. 11.7 [.461] 31.8 [1.250] Ref. Ø 12.7 [.500] Min. Panel Hole 18.2 [.718] Typ. 25.4 Ref. [1.000] Ø 15.9 Ref. [.625] Ø 14.3 Ref. [.562] 25.4 Sq. [1.000] Part No. 1057383-1 M/A-COM Model No. 3082-2242-00 Part No. 1058081-1 M/A-COM Model No. 3282-2240-00 Part No. 1057853-1 M/A-COM Model No. 3182-2240-00 SMA Jack – SMB Plug SMA Jack – OSMP Plug SMA Jack – SSMT or OSMT Plug 19.3 [.760] Ref. 14.2 [.560] 10.5 Ref. [.413] 6.4 Hex. [.250] Part No. 1060498-1 M/A-COM Model No. 5182-2240-00 Part No. 1056707-1 M/A-COM Model No. 2982-2240-00 Part No. 1055696-1 M/A-COM Model No. 2382-2240-00 SMA Flange Mount Jack – 7 mm Plug SMA 18 GHz Jack – 7 mm Plug MCX Plug – SMA Jack 19.1 Typ. [.750] 25.4 Sq. [1.000] Ø 3.2 Dia. [.125] 4 Plcs. 19.1 Hex. [.750] 2.0 [.080] 30.5 [1.200] Ø 22.4 Ref. [.880] 23.5 Ref. [.925] Part No. 1061750-1 M/A-COM Model No. 7082-2242-00 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 19.1 Hex. [.750] Ø 22.4 Ref. [.880] 30.9 [1.216] Ref. 6.4 Hex. [.250] Part No. 1053788-1 M/A-COM Model No. 2082-2700-00 Dimensions are in millimeters over [inches] 18.2 [.716] Part No. 1061072-1 M/A-COM Model No. 5882-2240-00 www.amp.com/communications/com Specifications subject to change. 263 Catalog 1307191 Revised 10-00 RF Coax Connectors Between Series Adapters (Continued) Jack-Plug (Continued) SMA 18 GHz Jack – N Series Plug N Series Flange Mount Plug – SMA 18 GHz Jack 31.8 [1.250] 31.5 [1.250] Ref. Ø 3.2 4 Plcs. [.125] 11.7 [.461] 6.4 [.250] 18.2 [.718] Typ. 2.0 [.080] Ø 21.0 Ref. [.828] OSP Plug – SMA Jack 6.4 Max. [.250] Panel Ø 12.7 [.500] Min. Panel Hole 13.7 [.538] Ø 7.6 [.300] 25.4 Sq. [1.000] Part No. 1057377-1 M/A-COM Model No. 3082-2240-00 Part No. 1058666-1 M/A-COM Model No. 3682-2242-00 Part No. 1059716-1 M/A-COM Model No. 4582-2240-02 SMA 18 GHz Jack – OSP Bulkhead Plug OSMP Jack – SMA Plug SSMT or OSMT Jack – SMA Plug 19.3 [.760] 11.4 [.447] 1.7 [.065] 3.2 [.125] Max Panel 0.03 Ø 6.15 +– 0.00 + .001 [.242 – .000 ] 16.0 Ref. [.632] 16.2 Ref. [.639] SMA Plug SMA Plug SSMT Jack OSMP Jack Recommended 7.9 Mounting Hole Hex. [.312] 11.1 Hex. [.437] 7.90 Hex. [.312] Part No. 1059756-1 M/A-COM Model No. 4585-2240-02 Part No. 1056708-1 M/A-COM Model No. 2982-2241-00 Part No. 1055697-1 M/A-COM Model No. 2382-2241-00 BNC Jack – Series 1.6/5.6 Plug BNC Plug – Series 1.6/5.6 Jack Series 1.6/5.6 Plug – Series 1.0/2.3 Jack Ø 9.6 [0.38] Ø 10.8 [0.43] Ø 14.5 [0.57] 44.3 [1.74] 45.4 [1.79] Ø 11.0 [0.43] Ø 10.8 [0.43] Part No. 1-1393665-7 Ø 4.1 [0.16] Ø 14.5 [0.57] Part No. 1-1393665-6 Ø 8.2 [0.32] 1) 9.2 [0.36] 33.0 [1.30] Part No. 2-1393670-2 Coupling Type A, B2, F2 Series Plug 1.0/2.3 – Series 1.6/5.6 Jack Ø 10.8 Ø 6.5 [0.43] [0.26] 8.9 [0.35] Ø 8.2 [0.32] 1) 34.5 [1.36] Part No. 2-1393670-3 Coupling Type A, B2, F2 1) Detent for jack 2 Only jackside 264 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Application Tooling Hand Tools Pneumatic Tools AMP PRO-CRIMPER II Hand Tools are economy versions of our AMP CERTI-CRIMP Hand Tools, featuring ratcheted crimp control to provide full die closure and help eliminate partial crimps. With an all new design, the PRO-CRIMPER II requires dramatically less hand force to produce the same connection as comparable tools. Dies are interchangeable. It’s the most versatile and reliable crimping tool in the midprice class. Recommended for networking installations, and commercial, industrial and institutional maintenance work. See Catalog 82276 for further information. The 626 Pneumatic Tool System, as the name implies, will apply a broad range of products in the 6-26 AWG [13-0.12 mm2] wire range. A basic 626 Pneumatic Tool System requires a power unit, a tool holder, a crimp head assembly and a die set when applicable. This premium system is well suited for low- to medium- volume production and harness assembly operations. Since the crimp head can be rotated to any angle, the operator can also work on more difficult terminations in confined equipment cabinets or enclosures. Typical PRO-CRIMPER II Hand Tool No. 58433-1 for 50 Ohm BNC Dual “O” Crimp Commercial Connectors Interchangeable tool holder assemblies and crimping heads are available to crimp a variety of products. Crimping heads for the earlier Model 2614 pneumatic power unit can be used with the 626 Pneumatic Tool System. If you are already using AMP hand tools, many crimp heads and die sets can be removed, attached to an adapter with quick pins and used with the 626 Pneumatic Tool System. An adapter is even available to accept lower cost die sets of the PRO-CRIMPER II hand tool. For more information, order catalog 124208. AMP CERTI-CRIMP Hand Tools are our top-of-the-line crimping tools featuring the original ratcheted crimp control. All tools are designed to exacting specifications, and manufactured using the highest quality materials to provide long service life. Recommended for low production runs, repairs and prototype work, and applications requiring consistent, highly-reliable terminations. See Catalog 65780 for further information. Typical CERTI-CRIMP Hand Tools with Integral (Non-Interchangeable) Dies No. 69140-1 for 50 Ohm BNC Single Crimp Mil Type Connectors No. 69477-1 for 50 Ohm BNC Dual Crimp Mil Type Connectors No. 189721-1 Bench Mount Assembly for Pneumatic Tool System (Optional) Fully adjustable stand allows operator free use of both hands — recommended for maximum productivity. No. 220015-1 for 50 Ohm N Connectors CERTI-CRIMP Hand Tool with Interchangeable Dies No. 69710 No. 856402-1 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 265 Catalog 1307191 Revised 10-00 RF Coax Connectors Application Tooling (Continued) Bench-Mounted Machines Stripping Tools AMP-O-LECTRIC bench-mounted, semi-automatic terminating machines may be used to apply RF products such as Commercial BNC and TNC Connectors, Miniature and Standard UHF Connectors, and Braid-Pic Contacts and Terminals. The Model G unit features interchangeable applicators, and is used to apply strip-form contacts. The “Coax” unit is used to apply loose-piece contacts and ferrules with dies that are mounted onto the machine. See Catalog 65828 and Customer Manual 409-2627 for further information. The hand-operated AMP Coaxial Cable Stripper features interchangeable, color-coded blade cassettes and V-blocks to accommodate 2- or 3-step stripping for cable diameters ranging from 2.54 [.10] through 7.62 [.30]. You strip cable by simply clamping and rotating the tool around the cable. See Instruction Sheet IS 2766 for further information. AMP-O-LECTRIC Model G, No. 354500 Series with AMP Crimp Quality Monitor For Use With Connector Type BNC Single Crimp BNC Commercial and UHF Miniature UHF Standard BNC Mil Type Dual Crimp BNC Commercial Dual Crimp Tool No. 603995-1 603995-2 603995-3 603995-5 603995-6 Semi-Rigid Cable Tooling The tools listed here are designed specifically to strip and terminate semi-rigid cable. These tools operate basically the same as the flexible cable tools, in that they produce uniform terminations time after time, without heat damage from soldering. Hand Tool for BNC and TNC Semi-Rigid Cable Connectors No. 59980-1 Frame only— does not include dies and locator 266 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Application Tooling (Continued) Hand Tool Kit for SMA and Blind Mate Connectors Pneumatic Tool for Terminating BNC, TNC, SMA and Blind Mate Connectors No. 59981-1 (for RG-402/U and RG-405/U Cable) No. 58318-1* This pneumatic tool is a bench-mounted, semi-automatic power tool designed for easy operation. The operator needs only to depress the trigger to complete a termination. It is used with the cable preparation machine to produce finished terminations. *Includes Locators 220241-1 and 308075-2. Dies are not included. Part Numbers Item Description Hand Tool Plug Locator (without Center Contact) Plug Locator (with Center Contact) Jack Locator Die Set for RG-402/U Cable (3.58 [.141] O.D.) Die Set for RG-405/U Cable (2.18 [.086] O.D.) Cutoff Fixture Cable Dressing Fixture Trimmer Tool Cable Bend Fixture Assembly Includes following 6 items: Bend Segment, RG-402/U (3.18 [.125] Radius) Bend Segment, RG-402/U (6.35 [.250] Radius) Bend Segment, RG-405/U Tool Holder Limiting Pin Conforming Block Hex Wrench Carrying Case Insert, Case 59980-1 Military (M22520/) 36-01 220220-2 36-06 220221-2 36-04 220222-2 36-05 312253-1 36-03 312253-2 36-02 311395-1 311396-1 312317-1 36-09 36-07 36-08 220224-1 36-10 311386-1 36-11 311386-2 36-12 311386-3 311392-1 307581-1 312067-1 21027-6 13126-1 13127-1 36-13 — — — — — — AMP Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 267 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 268 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Cable Assembly Capabilities Make AMP Your Advantage When your application demands a high-performance cable assembly for the Communications market, make AMP your advantage. We specialize in solving tough problems with assemblies designed and manufactured to meet the most demanding requirements. in connectors, we design and manufacture highperformance cable. Fact is, over 50% of our cable assemblies use AMP developed cable. By providing the match between cable, connector, and application, we supply cable assemblies that meet your exact needs. Why AMP? Quite simply because we can give you a comprehensive engineered solution to your application needs. Beyond our acknowledged leadership Every cable assembly must meet unique needs, whether these are related to speed and distance, to shielding and programmability, to special mechanical Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] issues like density or latching, to appearance, or to weight. We approach your cable assembly individually, using the resources and knowledge gained from years of experience generating custom solutions. By making AMP your partner in cable assembly design, you reduce risk and gain the assurance that you will receive the assembly — on time, to spec, and within budget. www.amp.com/communications/com Specifications subject to change. 269 Catalog 1307191 Revised 10-00 RF Coax Connectors Cable Assembly Capabilities (Continued) Product Radio Base Stations used as the main conduit to connect mobile phones to the central telecommunication backbone are placed in every conceivable environment on earth, sometimes in the most remote locations. The system designer is tasked with providing highly reliable interconnections throughout the cabinet with high performance at the lowest cost. From discrete power cabling to precision high power RF interconnects, Tyco can produce a cost effective solution of the highest quality to meet these demanding requirements. Our worldwide manufacturing locations allow us to supply locally manufactured products to you with short lead times. Low loss cable Phase match cable Heliax cable Standard RG cable Semi-rigid cable Testing Utilizing network analyzers, TDR, and intermodulation test equipment among others, our test labs allow extensive electrical and environmental characterization of your assembly. Since test locations are set up within the manufacturing facilities, tests such as these listed below can be 270 an integral part of the manufacturing process: ■ VSWR ■ Return Loss ■ Insertion Loss ■ Phase ■ Impedance ■ Intermodulation Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Cable Assembly Capabilities (Continued) Wherever you do business, you can do business with AMP We have strategically placed customer centers, low-cost manufacturing facilities, and innovative prototype and engineering centers. Because of these facilities, we can offer you a broad level of support as your local or regional supplier. Our facilities are typically ISO 9000 and CSA certified, and UL listed, and are tied together by a comprehensive global quality management plan, emphasizing our commitment to quality as a global leader in cabling and cable assemblies. Manufacturing Centers Engineering Centers Our cable assembly manufacturing centers are designed to meet your production requirements and delivery needs. These centers include: Whether the situation calls for a customized scientifically-modeled solution that is, verification of existing design, materials engineering/analysis, electronic testing/analysis, or specialized wire management and termination techniques, AMP has the technology and resources to exceed the expectations. ■ United States ■ Mexico ■ China ■ Brazil ■ Poland ■ Holland ■ Japan ■ Hungary Additionally, we are wellversed in manufacturing processes including crimping, phase matching, rotary stripping, induction soldering, and semi-rigid cable bending. Integral to each of these processes is a commitment to quality, providing you with increased reliability and availability. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Our team works closely with you, creates cable parameters, engineers application designs, and builds prototypes. The goal is to reduce your development time and costs through competent engineering. We have engineering centers in: ■ United States ■ Holland ■ China ■ Japan www.amp.com/communications/com Specifications subject to change. 271 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 272 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix A - Theory and Application Theory and Application As a leading manufacturer of RF products, AMP Incorporated produces a large variety of coaxial connectors. The proper selection and application of these connectors requires a knowledge of factors not involved in other types of connectors and terminals. The following paragraphs have been prepared to improve understanding of the theory behind RF connectors: Basic RF Theory1 RF energy travels by electromagnetic waves, and it is primarily the frequency of these waves that we are interested in. Briefly, if an oscillating voltage source is connected to a cable, a continuous electromagnetic wave will propagate along the cable. A sensor placed at some point on the cable would indicate a varying voltage (E field) as well as a current and magnetic field (H field) as the wave travels past it. This is called an electromagnetic wave because both electric and magnetic fields are varying. The wave shape is initially determined by the variation of the source with time. Figure 7 shows the radiant energy spectrum. Visible light, radio, television, x-rays and Gamma rays are all phenomenon of electromagnetic waves at different frequencies. This introduction will treat only those that are generated by an electrical source and propagated along a physical cable or other transmission media. That is, frequencies above zero and up to about 50 gigahertz. The majority of the technical terms, relative to RF and coaxial cable and connectors, used here-in and throughout this catalog are defined in the Glossary (Appendix E) starting on page 302. 1 Frequency or Wavelengths In the following paragraphs we will discuss waves in greater detail, including the relationship of frequency and wave length, how pulses are formed and used, how each differs from the other and the problems involved in their transmission. Sine Waves An RF wave is a sine wave, meaning that it smoothly swings from zero to a positive peak value, then back down past zero to a negative peak value, then back to zero to complete a 360 electrical degree cycle. The positive and negative peaks are always equal in amplitude. The two qualities which characterize this type of wave are amplitude and frequency (f). Figure 8 shows these two characteristics. Amplitude refers to the peak value attained by the wave and corresponds to voltage. Frequency refers to the number of oscillations per second. For example, the sign wave in Figure 8(B) has completed 12 cycles in one second. Therefore, we would say that this wave has a frequency of 12 cycles per second or 12 Hertz. The time for one complete cycle is defined as the period (T). The relationship between the period and frequency is given by the equation: f = 1 / T in Hertz A Peak Positive Amplitude Peak Negative Amplitude One Cycle Designation Applications VLF (Very Low Frequency) Commercial AC electricity, deep depth sounders, ultrasonic grinders, sonic oscillators 30 - 299.9 KHz LF (Low sonar Frequency) Shallow-to-medium depth sounders 300 - 2999.9 KHz MF (Medium Frequency) Commercial AM radio broadcasting, marine radio telephone, direction finders 1 Second 3 - 29.9 MHz HF (High Frequency) Citizen band radio, amateur radio, international broadcasting Figure 8 30 - 299.9 MHz VHF (Very High Frequency) VHF television (Channels 2 thru 13), commercial FM radio broadcasting, amateur radio, fire and police radio 300 - 2999.9 MHz UHF (Ultra-high Frequency) UHF television (Channels 14 thru 83), microwave ovens, aeronautical radionavigation 3 - 29.9 GHz SHF (Super High Frequency) Microwave communications, marine radar, aircraft tracking and airborne radars 30 - 299.9 GHz EHF (Extremely High Frequency) Space communications, radio astronomy 0 - 29.9 KHz Notes: 1. KHz = Kilohertz (1 thousand cycles per second) 2. MHz = Megahertz (1 million cycles per second) 3. GHz = Gigahertz (1 billion cycles per second) Figure 7 Radiant Energy Spectrum Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] B No. of Cycles 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 Typical Sine Wave Characteristics The wave travels away from the generator at speeds approaching the speed of light. When an electromagnetic wave travels in a medium other than air or vacuum, the speed for the wave is reduced by a factor of the square root of the dielectric constant ( ε. The velocity (v) of the propagation of a signal is given by: c __ v= ε Where c is the speed of light, 3 x 108 m/sec or 1.18 x 1010 in/sec, and ε is the dielectric constant of the medium. (See Table 1 for dielectric constants of various materials) The wavelength of a signal is given by the formula 10 c 1.18 x 10 λ = v/f = __________ _________ inches ε x f (GHz) ε x f (GHz) See Figure 9 www.amp.com/communications/com Specifications subject to change. 273 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix A - Theory and Application (Continued) Notice that rise time is the time required for the pulse to rise from 10% to 90% of its amplitude - not from zero to maximum. Rise and fall time is perhaps the single most important characteristic of a pulse in today’s high-speed digital equipment. Figure 11 shows that the faster the rise and fall time, the more pulses will fit in a given time frame. Inches 1000 Wavelengths 100 A 10 1 0.1 Time .001 GHz .01 GHz .1 GHz 1 GHz 10 GHz 100 GHz B Frequency (MHZ) (MHZ) FREQUENCY TEFLON (E=2.03) AIR (E=1.00) Figure 9 Table 1. Properties of Insulating Materials Dielectric Material _________ TFE Polyethylene Nylon TPX Polypropylene Acetal Dielectric Constant _________ 2.03 2.3 4.6-4.0 2.12 2.25 3.7 Operating Temperature Range __________________ -70 +250°C -60 +80°C -40 +120°C -65 +85°C -40 +105°C -65 +85°C Pulses The sine wave is most often used for communication purposes where intelligence is imposed on the wave by a variation in amplitude (amplitude modulation, AM) or by a variation in frequency (frequency modulation, FM). Pulses, on the other hand, are primarily used in computers and digital instrumentation. Since pulses are generally used for triggering purposes, the pulse rise/fall time, amplitude and width are the most important. Figure 10 shows a pulse and identifies these characteristics. Width 90% 90% Amplitude 10% 10% Fall Time Repetition Rate Rise Time Time Figure 11 Pulse Rise and Fall Time The bit rate for a system is the maximum rate of pulses per second that a system can process without causing data errors. The maximum performance can also be specified in terms of baud rate. The baud rate is defined as the number of characters (bytes) that are transmitted per second. Generally a character represents 10 bits (7 bits for the information, one parity bit, and two for start and stop, totalling 10). Now that we know why fast pulses are required, the next problem is how to obtain faster rise times. A pulse is made up of a great number of different frequencies, and the more high frequencies a pulse contains, the faster will be its rise time and the flatter will be its peak. To better understand this, refer to Figure 12. At A, you will see a fundamental frequency (1), its third harmonic (3), and the resultant waveform (S3), which is a combination of 1 and 3. Although this does not yet resemble a square wave, you will note that the rise time is decreased, and a dip appears at the peak. At B of Figure 12, we have added the fifth harmonic. Rise time is further decreased, and the peak is beginning to flatten out. At C the seventh harmonic has been included, and the resultant wave S7 begins to resemble a square wave. As more high frequency harmonics are added to the waveform, it will more closely resemble a square wave, and the squarer it becomes, the faster will be the rise time. Figure 10 Pulse Characteristics 274 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix A - Theory and Application (Continued) Fast rise times and short pulse widths require high frequency components. Two frequent causes of digital signal degradation can be (1) high capacitance of the transmission line and (2) impedence mismatches of connector transmission line or I/0 devices. Selection of an impedance-matched connector on a digital line, especially if short cable assemblies are used, can be as important as connector selection for an RF modulated line. Reflected pulses out of phase with the original pulse can cause false signals or high error rates in a digital system. Signal Integrity and Propagation To explain how to maintain signal integrity, it is necessary to review how the signal is configured in a cable and how it propagates. Ignoring digital signals for this discussion we will identify the issues that deal with the integrity of a sine wave. Consider a coaxial cable consisting of an inner conductor surrounded by a dielectric material and then an outer conductor (See Figure 13). The outer conductor may be a braid, a foil, or a solid metal. Since pulses with fast rise times are necessary in highspeed computers, any circuit element which could reduce or attenuate high frequency response is undesirable. Outer Conductor A d S3=1+3 D 1 Dielectric Material Center Conductor Figure 13 3 Diagram of a Cable An electromagnetic wave traveling in a coaxial cable produces an electric and a magnetic field between the inner conductor and the outer conductor (Figure 14). The electric (E field) is radial and varies in time. An alternating current flows along the inner conductor and the outer conductor. An oscillating magnetic field (H field) circles the inner conductor. S3 B S5=1+3+5 E H V 5 Figure 14 S5 Electric field (E) and magnetic field (H) belonging to the principal mode in a coaxial line. C The alternating current on a conductor is not spread throughout the conductor but is strongest at the surface and decays exponentially at points further into the conductor. This is called the skin effect. At a frequency of 1MHz, three skin depths is 0.0078” (95% of the current is within three skin depths of the surface) and at 10GHz three skin depths is 0.00078”. As a result, the current is on the outer surface of the inner conductor and the inner surface of the outer conductor over the entire range of interest for most RF systems. The dimensions and material beyond several skin depths have no effect on the wave; gold plated plastic will propagate as well as gold plated copper at sufficiently high frequencies. S7=1+3+5+7 7 Figure 12 Development of a Square Wave Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 275 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix A - Theory and Application (Continued) Attenuation Reflections A wave loses energy (attenuates) in several ways: (1) The resistance of the inner and outer conductors is small but can be significant over long lengths and will produce some heat. (2) The dielectric may be lossy; its resistance is high but not infinite, and some energy is lost. (3) Electromagnetic energy radiates at high frequencies; significant energy losses are caused by radiation of electromagnetic energy (the cable acts like an antenna). (4) Energy is reflected due to impedance mismatches. The combination of these four types of losses are referred to as the insertion loss of a transmission line system. Connectors have similar losses. When the characteristic impedance changes in a transmission line system, part of an incident wave is reflected. The reflection coefficient can be calculated as: ZR - ZO Vi Reflection Coefficient = ρ= _____ = _______ VR ZR + ZO Where Vi and ZO are the incident voltage and impedance of the first media. VR and ZR represent the reflected voltage and impedance of the media that caused the reflection. The decibel loss due to reflection is given by: Characteristic Impedance A parameter which defines the behavior of a cable, connector, or any propagating system is Characteristic Impedance, Zo. The characteristic impedance of a lossless cable is related to the inductance per unit length, L, and the capacitance per unit length, C, as follows: Zo = L/C in ohms The equivalent circuit of a transmission line is shown in Figure 15. R represents the conductor resistance for a unit length For a coaxial cable the characteristic impedance is given by: D Zo = 138 x Log10 ε d in ohms where D is the inner diameter of the outer conductor and d is the outer diameter of the inner conductor, respectively. Similar equations apply for other geometries such as two parallel wires. 1 Return Loss = 10 Log10 ( ____ ) dB 1-ρ 2 VSWR The traditional way to determine the reflection coefficient is to measure the standing wave caused by the superposition of the incident wave and the reflected wave. Traditionally the voltage is measured at a series of points using a slotted line. The ratio of the maximum divided by the minimum is the Voltage Standing Wave Ratio (VSWR). The VSWR is infinite for total reflections because the minimum voltage is zero. If no reflection occurs the VSWR is 1.0. VSWR and reflection coefficient are related as follows: VSWR = (1 + ρ)/(1 - ρ) L R Most present instrumentation measures the reflection coefficient and calculates the VSWR. C Z0 Figure 16 represents the direct relationship between VSWR and its equivalent in return loss (expressed in dB). Figure 15 Typical Transmission Line Schematic The maximum power is transferred between two systems if they have the same impedance. This is called impedance matching. However, impedance variations that are short compared to a wavelength can have a negligible effect on signal loss. Standard impedances are 50 ohm, 75 ohm and 93-125 ohm. Most systems use 50 ohm because it is a compromise between maximum power transmission and minimum line loss. The telephone industry and the broadcast industry use 75 ohm for minimum line attenuation. The need for low capacitance instrumentation cable has produced the 93-125 ohm systems. The higher impedances are generally achieved by changing the conductor diameters and by modifying the dielectric material to add air. 276 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Figure 16 VSWR vs. Return Loss Multiple Reflections If there is a series of impedance changes, each one will have a reflection coefficient. The total reflection coefficient is the vector addition of each of the individual coefficients accounting for the distance between reflections and the reflection of any reflected waves. Even though the calculations are difficult, a total VSWR can still be measured. Multiple reflections can produce a resonance phenomenon that is unique to wave theory. Properly understood some serious difficulties can be avoided. An example will make the point clear. Consider an electromagnetic wave with a wavewww.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix A - Theory and Application (Continued) length of 4 inches traveling on a cable that changes from 50 ohms to 25 ohms. The reflection coefficient is -.33, which means that one third of the incident voltage is reflected toward the source. Assume that one inch (one quarter wavelength) down the cable the impedance changes back to 50 ohm. Again, one third of the wave is reflected, but without any phase shift. It travels back to the first interface where one third of this reflected wave is reflected back toward the second interface. Two thirds of the wave is transmitted through the interface and travels back to the source. Since the first (reflected) wave is shifted 180 degrees at the reflection, and the second (transmitted-reflected-transmitted) wave is shifted 180 degrees because it traveled the one inch separation twice, the two waves are in phase. The net result is that the VSWR is much larger because the length of the 25 ohm section was just the right length to cause a resonance. If the length of the 25 ohm section had been one half wavelength, the two waves would have interfered and the VSWR would be at a minimum. λ/ 4 V in 50 Ω 25 Ω 50 Ω V out λ/ 4 .66V 1 V out .44V .33V .22V Reflections of Digital Signals The previous discussions dealing with attenuation, reflections and standing waves can apply to digital signals with some extra thought. A single pulse can be thought of as a combination of high frequency sine waves. The maximum frequency component in a square wave pulse can be calculated by this equation: f = 0.35/rise time where f = GHz when “t” is in nanoseconds Attenuation of the frequencies necessary to support the short risetime will produce a slower rise and possibly prohibit the pulse from ever reaching the detector. This ‘slurring’ of the pulse is similar to the behavior of an RC circuit and the attenuation is sometimes called capacitive attenuation. A series of pulses can demonstrate resonance. If a portion of a pulse is reflected at each interface, it is possible for them to come together and add up to form a new phantom pulse. The critical frequency here is the bit rate. Think of a sine wave with a frequency the same as the bit rate; if it will resonate in the cable, the pulses will also. Extra pulses caused by resonance might easily result in an error signal from the receiving system requesting a retransmittal. The final result would be a communication system that is much slower than intended. Cut-off Frequency The cut-off frequency of a coaxial transmission line is the frequency at which modes of energy transmission, other than the “TEM” mode, can be generated. 7.5 7.5 fco (in GHz) GHz) fco = = ______ (in εε(D+d) (D+d) .07V .15V (D and d are measured in inches) Types of Transmission Lines Impedence Mismatch V in = 1 Volt VR =.48 Volt V out =.52 Volt Figure 17 Multiple Wave Reflections (Caused by Impedance Mismatch) In summary, avoid cable lengths, printed circuit board paths, or connectors that are multiple of one quarter (λ/4, 3λ/4, etc.) of the intended signal transmission wavelength. Coaxial cables, when manufactured, also have periodic variations in diameter that result in periodic changes in impedance (Zo), that can cause significant levels of reflected signal (high return loss) at specific frequencies. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Twin Lead transmission cable is generally used where impedance matching alone is important, since it provides only minimal shielding. Impedance values of 300 ohms and 600 ohms are common. Lower impedance values require closer spacing of the conductors and are not normally available in this type of cable. A typical application for twin lead cable is in antenna lead wire for television sets. Twisted Pair is a variation of the twin lead type. It consists of two lengths of ordinary hookup wire twisted together. A twisted pair provides relatively constant impedance plus better magnetic shielding than twin lead cables. It is flexible, inexpensive, easy to terminate and is used extensively by the computer industry. However, it should not be used when maximum shielding is required. www.amp.com/communications/com Specifications subject to change. 277 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix A - Theory and Application (Continued) Shielded Twisted Pair Cable is used to eliminate inductive and capacitive coupling. Twisting cancels out inductive coupling, while the shield eliminates capacitive coupling. Most applications for this cable are between equipment, racks and buildings. Flexible (Braided) Coaxial Cable is by far the most common type of closed transmission line because of its flexibility. It is a coaxial cable, meaning that both the signal and the ground conductors are on the same center axis. The outer conductor is made from fine braided wire, hence the name “braided coaxial cable”. This type of cable is used in practically all applications requiring complete shielding of the center conductor. The effectiveness of the shielding depends upon the weave of the braid and the number of braid layers. AMP manufacturers connectors for cable sizes ranging from less than 1/8 in. diameter, for low power applications of around 50 watts, to over 1/2 in. diameter for power of 850 watts at 100 MHz and voltages up to 5000. In addition to power handling capabilities, cables are available for high frequency applications, high and low temperature applications, severe environmental applications and many other specialized uses. Triaxial Cable is used when higher “shielding” efficiency characteristics are required in applications similar to those using shielded twisted pair cable. Signal Conductors Outer Conductor Insulation Outer Conductor Dielectric Dielectric Semirigid Coaxial Cable uses a solid tubular outer conductor rather than the braided type, so that all the RF energy is contained within the cable. One of the drawbacks of braided cable is that the shielding is not 100% effective, especially at higher frequencies. This is because the braided construction can permit small amounts of short wavelength (high frequency) energy to radiate. Normally this does not present a problem; however, if a higher degree of shielding is required, semirigid coaxial cable is recommended. For applications using frequencies higher than 30 GHz a miniature semirigid cable is recommended. Various connectors are available from AMP to terminate these cables. Ribbon Coaxial Cable is a relatively recent AMP innovation which combines the advantages of both ribbon cable and coaxial cable. AMP currently provides both the cable and the insulation displacing coaxial connector to terminate the cable. Each individual coaxial cable consists of the signal conductor, dielectric, a foil shield and a drain wire which is in continuous contact with the foil. The entire assembly is then covered with an outer insulating jacket. The unique manufacturing feature of this cable is the precise placement of the drain wires to permit gang stripping of the outer jacket and foil. The major advantage of this cable is the speed and ease with which it can be mass terminated with the AMP insulation displacement technique. They can also be separated into individual coaxial lines and terminated with standard coaxial connectors as required. Signal Conductors Middle Conductor Dielectric Insulation Often you will hear the term “shielded cable”. This is very similar to coaxial cable except the spacing between center conductor and shield is not carefully controlled during manufacture, resulting in non-constant impedance. Figure 18 Twin Conductor and Triaxial Cable -1000 9 8 7 6 5 4 ath he dS li So -300 -200 Triax -100 -80 -60 -40 Double Braid Single Copper Braid -30 -20 -10 .01 GHz .1 GHz 1 GHz 10 GHz Figure 19 Shielding Efficiencies 278 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix B - White Bronze High Quality Surface Plating & Excellent Intermodulation Performance for RF Connectors Product Facts ■ Low intermodulation ■ High corrosion resistance ■ Low porosity ■ Low RF losses ■ Wear and scratch resistance AMP’s industrial electroplating facilities is one of the most advanced in the world. Need more information? Call Technical Support Center at 1-800-522-6752 for product and tooling information. The Technical Support Center is staffed with specialists well versed in all AMP products. The Center can provide you with: ■ Engineering Support ■ Catalogs ■ Technical Documents ■ Product Samples ■ AMP Authorized Distributor Locations AMP’s White Bronze surface finish represents a dramatic improvement upon the wear characteristics and life expectancy of silver plating, at the same time offering a far better electrical performance than nickel. White Bronze plated connectors exhibit intermodulation characteristics significantly better than stainless steel or nickel plated products. Silver has always been the preferred finish from an electrical standpoint but its corrosion and wear characteristics especially in harsh conditions are often unacceptable. While nickel is an extremely rugged finish it has properties undesirable in many RF applications; including, high RF and insertion losses, poor intermodulation performance, high permeability and poor screening effectiveness. AMP’s White Bronze is composed of copper, tin and zinc which are applied simultaneously to produce a finished color similar to stainless steel. With one of the most advanced industrial electroplating facilities in the world AMP can achieve the levels of control over the complex galvanic process necessary in the application of this alloy. AMP’s White Bronze is similar in composition and performance to other copper/ tin/zinc alloys developed in the industry such as Sucoplate® and BBR. Comprehensive conditioning tests have been performed to provide a thorough evaluation of AMP’s White Bronze plated connector bodies. The tests were performed to the specifications of the European and International RF connector standards — CECC 22000/IEC 68-2-14/ IEC 169-1. The results are summarized on page 281. Deposit Characteristics Composition — Copper (55-60%), Tin (20-25%), Zinc (15-20%) Density — 7.9-8.1 g/cm3 Hardness — 300-380 HV ■ AMP Fax Service... 24 hours a day Passivation — Immersion Chrome ■ AMP Internet Home Page: www.amp.com Sucoplate® is a plating trademark for Huber & Suhner. BBR is a plating trademark for Radiall. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 279 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix B - White Bronze (Continued) Low Intermodulation Products Dissimilar metals, finishes and discontinuities within a coaxial line structure give rise to Intermodulation Products (IMP). This is of particular concern in applications requiring low levels of intermodulation, such as cellular base stations and antennas. White Bronze plated connectors offer better IMP performance and lifetime characteristics than nickel. Due to the similarity of electrolytic potentials and the non magnetic properties of the finish, levels of intermodulation are commensurate with silver and far in excess of stainless steel/nickel connectors. At the same time the excellent wear characteristics and durability of the finish ensure that the intermodulation life of the connector is greater than silver. The life is also improved as a direct result of the excellent corrosion resistance properties of White Bronze; thereby minimizing metal/metal oxide junctions. Highly Corrosion Resistant Even under continuous exposure to harsh environments White Bronze retains its aesthetic appearance. Unlike silver it does not discolor when exposed to 280 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] sulphur, potassium sulphides etc., neither is there any build up in oxide layers as is the case with nickel. Furthermore, White Bronze parts have successfully passed all international salt spray tests (MIL, BS, CECC, IEC). Consequently, any White Bronze plated connectors in contact with stainless steel, silver, nickel or nickel containing finishes carry no risk of corrosion as a result of any chemical potential difference. In conditions of continuously high temperatures (>100°C) and/or excessive humidity (>100%) there is no build up of foreign layers which may affect contact resistance. Low RF Losses Low Porosity and No Reaction with Contact Surfaces Less than 2µm of White Bronze is needed to create a completely nonporous, corrosion resistant surface. AMP applies White Bronze to a thickness of between 2µm and 3µm. This compares favorably with the typical plating thickness of nickel (>10µm) and consequently, variations in plating depth are significantly less. White Bronze does not alloy with brass and since its coefficient of expansion is virtually identical to that of brass, rapid temperature shocks (-50°C/200°C) do not cause blistering or cracking of the plating. The electrolytic potential of White Bronze is approximately that of brass. The relative permeability (µr) of AMP’s White Bronze is 1 giving rise to low RF losses even at high frequencies. As a direct result of the good conductivity of the finish, skin depth is minimized further reducing insertion loss and ensuring a better impedance match across the frequency range of the connectors. Non Magnetic Finish AMP’s White Bronze contains no ferrous materials and so has no magnetic properties. This is particularly desirable in many RF applications. Wear and Scratch Resistant The hardness of AMP’s White Bronze at 300-380HV is more than double that of silver and marginally harder than platings containing nickel. This gives a scratch resistance which is rarely surpassed and makes it ideal for high mating applications. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix B - White Bronze (Continued) Low Coefficient of Friction White Bronze is available on all products, including 7-16, N, TNC, OSP and SMA. The coefficient of friction is approximately 70% that of silver to give lower insertion forces and smoother coupling. These properties combine to produce a harder wearing, longer lasting finish which prolongs connector life and reduces the ongoing cost of ownership. AMP’s White Bronze Environmental Test Four groups of conditioning tests were performed to provide a comprehensive evaluation of AMP’s White Bronze plated connector bodies. The tests were performed to the specifications of the European and International RF connector standards CECC 22000/ IEC 68-214/IEC 169-1. Full details and relevant data are available from AMP and results are summarized below. Test 1 - Industrial Atmosphere & Temperature Endurance 1.1 Industrial Atmosphere Exposure to Sulphur Dioxide Atmosphere (as specified in IEC 68-2-42 Test Kc) for 21 days of mated connectors, previously subjected to 500 matings, to determine the influence of sulphur dioxide on the corrosion resistance Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] properties of White Bronze Plating. Contact resistance measured after matings and sulphur dioxide exposure was less than 5% (0.23mohm) of the permissible specification. 1.2 High Temperature Endurance Exposure to temperatures of 85°C ±5°C for 250 hours, to determine the impact of prolonged high temperatures on plating adhesion. Prior to testing the connectors were subject to 500 matings. Results showed no visual deterioration in plating finish (blistering, cracking etc.) and the results of outer conductivity performance were comparable to Test 1 (above). Test 2 - Rapid Temperature Change & Damp Heat Steady State tivity performance were comparable with Test 1 (above). Test 3 - Soldering Heat 3.1 Resistance to Soldering Heat Exposure to concentrated soldering heat (250°C) for 10 seconds to evaluate any possible deterioration in plating finish. No deterioration detected. Test 4 - Salt Mist & Mechanical Endurance 4.1 Salt Mist Exposure to salt mist spray (as defined in BS 2011 Pt. 2.1 Ka) for 48 hours to evaluate the uniformity of protective coatings, any visual deterioration, or impact on electrical performance. No visual deterioration, outer conductivity performance were comparable with Test 1 (above). 2.1 Rapid Temperature Change Exposure to -55°C and +85°C for 15 minutes, transition time 2-3 minutes, 50 cycles. To determine possible plating deterioration caused by prolonged and rapid temperature change. No visual deterioration, outer conductivity performance were comparable with Test 1 (above). 4.2 Mechanical Endurance Electrical and visual evaluation of the connectors after 500 matings to determine any electrical or visual deterioration. No visual deterioration, outer conductivity performance were comparable with Test 1 (above). 2.2 Damp Heat Steady State Exposure to 93% relative humidity (at 40°C) for 10 days. To determine plating adhesion. No visual deterioration, outer conduc- AMP offers White Bronze on all products including 7-16, N, TNC, SMA and OSP. For more information on White Bronze contact your local AMP Sales Office. Availability and Ordering www.amp.com/communications/com Specifications subject to change. 281 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix C - Intermodulation in RF Coaxial Connectors Product Facts ■ High quality plating to 6µm for IM-sensitive products ■ Restrict materials to copper and its alloys ■ Avoid the use of stainless steel, nickel, ferrites, etc. in the signal path ■ Quality machining ■ Ensure, by design, a properly defined contact interface at connector, panel and contact interfaces ■ Avoidance of crimps The increased demand from the mobile communication industry to provide greater channel capacity coupled with the increased sensitivity of receivers has exposed a condition within RF Coaxial Connectors referred to as Intermodulation Distortion (IMD). This condition occurs when non-linearities within the connectors act as imperfect diodes to generate other frequencies known as Intermodulation Products (IMP). Some of these frequencies appear within the receive band and effectively block the channel. The purpose of this application note is to outline the basic causes of Intermodulation and the techniques AMP has undertaken to minimize this condition. Need more information? Call Technical Support Center at 1-800-522-6752 for product and tooling information. The Technical Support Center is staffed with specialists well versed in all AMP products. The Center can provide you with: ■ Engineering Support ■ Catalogs ■ Technical Documents ■ Product Samples ■ AMP Authorized Distributor Locations 282 IM Basics Modern developments in base stations for GSM, DCS 1800 and PCS 1900 have necessitated the use of “7-16”, “4.1/9.5” and “N” connectors due to the increased power requirements. The requirements for performance are typically in the order of - 160 dBc to -163dBc (when working in dBc) or -120dBm (when working in dBm), both with 2 x (+43dBm) tones. The requirement is so stringent because the connectors are used in post-filtering sections of the transmit path (between the diplexer and the antenna) and also because the system is a full duplex system where the multiple-carrier transmit path is also the receive path. In a truly linear system, the output is directly proportional to the input, following the form of y=mx+c (see fig. 2). Coaxial connectors have traditionally been viewed as following this pattern. In reality, there have always been non-linearities present in coaxial connectors. These were not readily apparent as the resultant IM products were significantly below the noise floor of the system due to relatively weak carrier signals. This situation becomes apparent when the incident power is raised above 30 dBm. The small non-linearities have a characteristic similar to a square-law (see Fig 3). The distortion to the waveform is evident, the positive Linear vs. Non-linear Response Fig. 2 12 Linear Fig. 3 120 10 100 8 80 6 60 ■ AMP Fax Service... 24 hours a day 4 40 2 20 ■ AMP Internet Home Page: www.amp.com 0 0 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Non-linear www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix C - Intermodulation in RF Coaxial Connectors (Continued) IM Basics (Continued) Spectrum of products in a 2-tone system 1/2 cycle being significantly greater in amplitude than the negative 1/2-cycle. When converted to the frequency domain, this waveform consists of the desired fundamental plus a decaying series of related harmonics that, in themselves, interact with other carriers present on the transmission line. % Fig. 4 120 Carriers F1 F1 100 Rx band 80 The effect of this interaction produces additional frequencies, some of which occur where they are least wanted (see fig. 4). The 2F1-F2 (3rd order IMP), 3F1-2F2 (5th order IMP) and 4F1-3F2 (7th order IMP) products can all manifest in the receive band and, if sufficiently large, effectively block a channel by making the base station receiver think that a carrier is present when one is not. Tx 2F1-F2 band 2F2-F1 60 3F1-2F2 4F1-3F2 40 3F2-2F1 4F2-3F1 20 0 Frequency (MHz) Potential causes of IM in Coaxial Connectors There are numerous factors which can affect intermodulation performance in RF coaxial connectors. Identified below are the most likely sources of concern: ■ Contaminated plating solution ■ Insufficient plating thickness ■ Corrosion ■ Dissimilar metals in intimate contact ■ Magnetic materials in the signal path ■ Low contact pressure ■ Less than 360-degree contact ■ Poor surface finish ■ Debris and dust within the connector ■ Convoluted signal path Remedies for IM in RF Coaxial Connectors To combat the above identified IM sources, AMP undertakes precautions during the design and manufacture of the product, as summarized below: ■ Effect of surface roughness Fig. 5 High quality plating to 6µm for IM-sensitive products 1.5 Metal The plating must also be free from contaminants and properly passivated with a chromate passivate. Silver has been the preferred plating material as it possesses the lowest practical resistivity thereby minimizing interface contact resistances. AMP also offers a unique White Bronze plating finish which provides excellent durability, tarnish resistance and nonmagnetic properties ideal for low intermodulation. During testing with a system noise floor of -145 dBm, the difference in performance between AMP’s silver-plating and AMP’s White Bronze finish is not discernible (refer to White Bronze Application Note 1307057). ■ Restrict materials to copper and its alloys. This ensures maximum plating adhesion and minimum electrochemical potential difference between the base materials and their over-platings. ■ Avoid the use of stainless steel, nickel, ferrites, etc. in the signal path Magnetic and para-magnetic materials will only compound non-linearites and give poorer interface contact resistances. During experimentation, AMP discovered a degradation in performance of 20dB when nickel plate was used. The presence of magnetic or para-magnetic materials will also cause the forward IMP figure to differ from the reverse IMP. ■ Quality machining Surface finish is paramount. The signal propagates within a “skin” if this skin is too rough, the signal will repeatedly transition through metal and surface oxide layers, thereby creating Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] 1 Air Oxide 0.5 0 -0.5 Signal flow -1 -1.5 the same effect as a poor panel contact (see fig. 5). For IMsensitive designs AMP ensures 0.4µm is the maximum. ■ Contact design This primarily affects the connector interface. Repeated matings can generate small amounts of plating from the individual parts. These oxidize and interfere with the mechanical (and therefore electrical) mating of connectors. The oxidized debris gives further rise to metal and surface oxide junctions and consequently, higher IM products. ■ Ensure, by design, a properly defined contact interface at connector, panel and contact interfaces Insufficient contact force will give rise to metal to oxide junctions. The classic rectifiers were metal oxide by composition. Axial maximum material condition at the connector interface is critical in order to ensure minimum mismatch and maximum www.amp.com/communications/com Specifications subject to change. 283 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix C - Intermodulation in RF Coaxial Connectors (Continued) Remedies for IM in RF Coaxial Connectors (Continued) potential of a butt-contact. Panel interfaces generally concern the physical contact of the connector body to the panel. In this case, it has been determined that a protruding feature as close as possible to the body bore will give the best IM performance. The applied mounting force is concentrated in the surface area of the protrusion which, on engagement with the panel, punctures the existing oxide layer to give a metal-to-metal, gas-tight junction. ■ Avoidance of crimps Crimps, by nature, can only give multiple point-contact rather than 360-degree contact and also cause a variability in the position of electrical contact during dynamic testing. IM products will therefore be greater. It has been found that soldered center contacts and clamp/solder outer contacts give the best static and dynamic IM performance. Improving IM Connector Design AMP continues to pursue design techniques which improve intermodulation performance to address emerging telecommunication market needs. A state of the art intermodulation test facility and participation on the international (IEC SC46D WG5) committee to develop standard test practices ensures our commitment to the understanding of intermodulation characteristics. This applied technology base is instrumental in developing innovative low intermodulation products for 7-16, Type N, SMA and OSP interfaces. Most commonly asked questions regarding Intermodulation 1. Why is intermodulation such a concern for cellular infrastructure equipment? Are there ways to test for intermodulation in an RF coaxial connector? The primary concerns for cellular service providers today are channel efficiency and clarity of transmission. Growth in demand for mobile communications has created a need to operate equipment at greater capacities and reliability to service the competitive market. Intermodulation degrades or limits the ability of the service provider to operate at optimal levels of performance and may ultimately cause subscribers to experience poor call quality. Intermodulation has become an important factor in system selection to ensure the best possible network service. Yes, very sophisticated methods are needed to test for intermodulation in RF connectors. The test system must utilize extremely sensitive filtering or clean amplification so that the equipment itself has a very low intermodulation noise floor. There is not yet a standardized approach to testing, although an international committee has been formed in the connector industry to address the situation. AMP has a state of the art test facility where our designs are optimized for low intermod performance and where further analysis on the effects of this phenomena can be studied. 2. 6. Where is intermodulation most likely to occur in cellular infrastructure equipment? Intermodulation is typically of greatest concern between the filtering elements of the system and the antenna. The introduction of higher power levels for the transmit side of the equipment creates greater potential for intermodulation to occur. This is why the majority of focus for intermodulation concerns 7-16, Type N, SMA and 4.1/9.5 connector interfaces. 3. Is intermodulation a recent development? Intermodulation has always been inherently present in RF coaxial connectors but may be relatively imperceptible in some devices for a variety of reasons. The amount of power applied to an RF connector determines the relative IM threshold which can be observed. Intermodulation is therefore more likely to cause concern in a higher power system, for example, utilizing a 7-16 connector interface rather than an equivalent low power OSX solution. The trend toward higher power digital cellular systems creates the need for greater intermodulation sensitivity. 4. What is the best method of cable attachment for IM sensitive cable assembly applications? Soldering and clamping are preferred methods due to the 360degree point of contact created at the cable to connector interface. Such intimate contact improves the overall contact resistance leading to improved IM characteristics. In addition, it is also better to solder the center conductor of the connector to the cable versus crimping due to the improved contact resistance path and elimination of voids. 284 5. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] Is intermodulation in coaxial connectors frequency dependent? No. Because coaxial connectors are broadband devices there is no frequency dependency. Some apparent variability can be detected during testing but this is not due to the connector. The impedance matches of the output diplexer/triplexer and terminations are the causes of the variations and should not be incorrectly attributed to the connector/assembly. AMP Interconnect Business Unit has demonstrated that by varying the impedance match of the test station termination, a DUT can show 15dB better IMP3 than exists in reality. 7. IMP3 in mixers follows a 3dB/dB relationship. What is it for connectors? The relationship is identical. Taking the 3rd order (2F1-F2): varying the power of F2 gives an IMP3 relationship of 1dB/dB whereas varying the power of F1 gives a relationship of 2dB/dB as the IMP is derived from the 2nd harmonic of F1. This gives a total of 3dB/dB when symmetrically varying both carrier powers. 8. I am buying a complete cable assembly from AMP. How do I interpret the IMP result now? With caution! It is AMP’s policy when testing devices to move away from the normal static test to a dynamic test where the cable termination interfaces are mechanically exercised during live IM conditions. It is also a good indicator to customers of the build quality of the assemblies. A dynamic evaluation has shown 15dB degradation in IMP performance for poor assemblies and even as much as 50dB for bad ones.It is therefore strongly advisable that IM performance figures are stated in the context of a dynamic measurement. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications Abbreviations SCCad Br......Silver covered cadmium bronze GS.................Galvanized steel TCCS ............Tin copper covered steel SSC ..............Silver covered strip HR.................High resistance wire SA .................Silver covered alloy Dielectric PE .................Solid polyethylene PTEE .............Solid polyetrafluoroethylene PIB ................Polyisobulylene, Type B, per MIL-C-17 Rubber ..........Per MIL-C-17D Sil .................Silicone rubber PS .................Polystyrene Jacket Material PVC-I ............Black polyvinylchloride, contaminating, Type I, per MIL-C-17D PVC-II ...........Gray polyvinylchloride, noncontaminating, Type II, per MIL-C-17D PVC-IIA.........Black polyvinylchloride, noncontaminating, Type IIA, per MIL-C-17D PE-III.............Clear polyethylene PE-IIIA ..........High molecular weight, black polyethylene, Type IIIA, per MIL-C-17D FG Braid V ....Fiberglass, impregnated, Type V, per MIL-C-17D FEP-IX ..........Fluorinated ethylene propylene, Type IX, per MIL-C-17D PUR ..............Polyurathane, black specific compounds SIL/DAC-VI...Dacron braid over silicone rubber, Type VI, per MIL-C-17D Rubber ..........Per MIL-C-17D Conductors and Braid Materials AL .................Aluminum SCAAI ...........Silver covered copper covered aluminum BC.................Bare copper SC.................Silver covered copper CCS ..............Copper covered steel TC .................Tinned copper SCCS ............Silver covered copper covered steel RG/U Type Cable Inner Conductor Dielectric Material DOD 4 0.81 BC .0320 1.29 BC .0508 1.29 SC .0508 1.29 SC .0508 0.72 CCS .0285 0.72 CCS .0285 0.91 BC .0359 2.17 .0855 7/0.72 BC .0285 2.17 .0855 7/0.72 BC .0285 2.17 .0855 7/0.72 SC .0285 2.17 .0855 7/0.72 SC .0285 2.17 .0855 7/0.72 SC .0285 2.17 .0855 7/0.72 BC .0285 2.17 .0855 7/0.72 BC .0285 1.21 .0477 7/0.4 TC .0159 1.21 .0477 7/0.4 TC .0159 1.21 .0477 7/0.4 TC .0159 PE Air-Space PE .295 .116 4.7 .185 4.6 .181 4.6 .181 4.7 .185 4.7 .185 6.35 .250 PE 5 5A 5B 6 6A 7 8 8A 9 9A 9B 10 10A 11 11A 12 Number/Type of Shielding Braids Jacket Material 2/BC PVC-1 2/BC PVC-1 2/SC PVC-II 2/SC PVC-IIA O.D. Weight (lb/ft) 2/Inner SC Outer BC 2/Inner SC Outer BC PVC-IIA 1/BC PVC-I 5.74 .226 8.43 .332 8.33 .328 8.33 .328 8.43 .332 8.43 .332 9.4 .370 7.24 .285 1/BC PVC-I PE 7.24 .285 .285 1/BC PE 7.11 .280 PE PE PE PE PE PVC-II Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .025 50 30.8 40 80 1900 Use RG58C .088 52.5 28.5 40 80 3000 Use up to 100 MHz .088 50 30.8 40 80 3000 Use RG212 .087 50 30.8 40 80 3000 Use RG212 .081 76 20.0 40 80 2700 Use RG6A .082 75 20.6 40 80 2700 Good Attenuation Stability .080 95 12.5 40 80 1000 Use RG63B 10.29 .405 .106 52 29.5 40 80 4000 Use RG213 PVC-IIA 10.29 .405 .106 52 29.5 40 80 5000 Use RG213 2/Inner SC Outer BC PVC-II 10.67 .420 .140 51 30.0 40 80 4000 Use RG214 7.11 .280 2/SC PVC-II 10.67 .420 .140 51 30.0 40 80 4000 Use RG214 PE 7.11 .280 2/SC PVC-IIA 10.67 .420 .150 50 30.8 40 80 5000 Uase RG214 PE 7.24 .285 1/BC PVC-II w/Armor 11.76 .463 .146 52 29.5 40 80 4000 Use RG215 PE 7.24 .285 1/BC PBC-IIA w/Armor 11.76 .463 .146 52 29.5 40 80 5000 Use RG215 PE 7.24 .285 1/BC PVC-I 10.29 .405 .096 75 20.6 40 80 4000 Use up to 100 MHz PE 7.24 .285 1/BC PVC-IIA 10.29 .405 .096 75 20.6 40 80 5000 Use up to 1000 Mhz PE 7.24 .285 1/BC PVC-II w/Armor 11.76 .463 .141 75 20.6 40 80 4000 Use RG12A PE Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 285 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 12A 13 13A 14 14A 15 16 17 17A 17B 18 18A 19 19A 20 20A 21 21A 22 22A 22B 23 23A 24 286 Inner Conductor Dielectric Material DOD Number/Type of Shielding Braids 1.21 .0477 7.24 PE 7/0.4 TC .285 .0159 1.21 .0477 7.11 PE 7/0.4 TC .280 .0159 1.21 .0477 7.11 PE 7/0.4 TC .280 .0159 2.59 BC 9.4 PE .1020 .370 2.59 BC 9.4 PE .1020 .370 1.45 CCS 9.4 PE .0571 .370 2.59 BC 11.68 .1250 PE .460 Tube 4.78 BC 17.27 PE .1880 .680 4.78 BC 17.27 PE .1880 .680 Cancelled, Reassigned New Nomenclature, RG177 4.78 BC 17.27 PE .1880 .680 4.78 BC 17.27 PE .1880 .680 6.35 BC 23.11 PE .2500 .910 6.35 BC 23.11 PE .2500 .910 6.35 BC 23.11 PE .2500 .910 6.35 BC 23.11 PE .2500 .910 1.29 4.7 0508 PE .185 High Res. Wire 1.29 4.7 .0508 PE .185 High Res. Wire 2 Cond. 1.16 .0456 7.24 PE 7/0.39 BC .285 .0152 2 Cond. 1.16 .0456 7/0.39 BC .0152 2 Cond. 1.16 .0456 7/.0.39 BC .0152 2 Cond. 2.17 .0855 7/0.72 BC .0285 2 Cond. 2.17 .0855 7/0.72 BC .0285 2 Cond. 2.17 .0855 7/0.72 BC .0285 Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .141 75 20.6 40 80 5000 Use up to 1000 MHz 10.67 .420 .126 74 20.8 40 80 4000 Use RG216 10.67 .420 .126 52 20.8 40 80 4000 Use RG216 .216 52 29.5 40 80 5500 Use RG217 .216 76 29.5 40 80 7000 Use RG217 .197 52 20.0 40 80 5000 Use up to 1000 MHz .254 52 29.5 40 80 6000 Use up to 1000 MHz .460 52 29.5 40 80 11,000 Use up to 1000 MHz .460 52 29.5 40 80 11,000 Use RG218 .585 52 29.5 40 80 11,000 Use RG219 .585 52 29.5 40 80 11,000 Use RG219 .740 52 29.5 40 80 14,000 Use RG220 .740 52 29.5 40 80 14,000 Use RG220 .925 52 29.5 40 80 14,000 Use RG221 .925 53 29.5 40 80 14,000 Use RG221 Jacket Material O.D. Weight (lb/ft) 1/BC PVC-IIA w/Armor 11.76 .463 2/BC PVC-I 2/BC PVC-IIA 2/BC PVC-II 2/BC PVC-IIA 2/BC PVC-I 1/BC PVC-I 1/BC PVC-II 1/BC PVC-IIA 1/BC PVC-II w/Armor PVC-IIA w/Armor 1/BC PVC-II 1/BC PVC-IIA 1/BC 13.84 .545 13.84 .545 13.84 .545 16 .630 22.1 .870 22.1 .870 23.50 .925 23.57 .928 28.45 1.120 28.45 1.120 29.92 1.178 29.92 1.178 1/BC PVC-II w/Armor PVC-IIA w/Armor 2/SC PVC-II 8.43 .332 .087 53 29.0 40 80 2700 Use RG222 2/SC PVC-IIA 8.43 .332 .087 95 29.0 40 80 2700 Use RG222 1/TC PVC-I 10.29 .405 .105 95 16.0 40 80 1000 Balanced Line w/Twisted Cond. 1/BC PE 7.24 .285 2/TC PVC-II 10.67 .420 .151 95 16.0 40 80 1000 Balanced Line w/Twisted Cond. PE 7.24 .285 2/TC PVC-IIA 10.67 .420 .151 125 16.0 40 80 1000 Balanced Line w/Twisted Cond. PE,2 Cores 9.65 .380 125 12.0 40 80 3000 Use RG23A PE,2 Cores 9.65 .380 125 12.0 40 80 3000 Dual Coaxial Balanced Line .670 12.0 2/Individual 40 80 3000 Use RG24A PE,2 Cores 9.65 .380 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 2/Inidividual Inner Common Outer BC 2/Individual Inner Common Outer BC 2/Individual Inner Common Outer BC PVC-I PVC-IIA PVC-I w/Armor 16.51 x .490 .650 .490 24 .945 16.51 x .490 .650 .490 24 .945 25.48 1.003 19.81 .780 Dimensions are in millimeters over [inches] .670 www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 24A 25A 26A 27A 28B 29 30 31 32 33 34 34A 34B 35 35A 35B 36 37 38 39 40 41 42 Inner Conductor 2 Cond. 2.17 .0855 7/0.72 BC .0285 1.49 .0585 19/0.3 TC .0117 1.49 .0585 19/0.3 TC .0117 2.35 .0925 19/0.47 TC .0185 2.35 .0925 19/0.47 TC .0185 0.81 BC .0320 1.21 .0477 7/0.4 BC .0159 2.17 .0855 7/0.72 BC .0285 2.17 .0855 7/0.72 BC .0285 2.59 BC .1019 2.17 .0855 7/0.72 BC .0285 1.9 .0747 7/0.63 BC .0249 1.9 .0747 7/0.63 BC .0249 2.91 BC .1144 1.6 0.63 2.65 BC .1045 2.65 BC .1045 4.11 BC .1620 0.81 TC .0320 1.15 TC .0453 0.64 CCS .0253 0.64 CCS .0253 1.24 .0490 16/0.25 TC .0100 0.72 .0285 Res. Wire Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .670 125 12.0 40 80 3000 Use RG23A 12.83 .505 .205 48 50.0 40 80 10,000 — Rubber-IV w/Armor 12.27 .483 .189 48 50.0 40 80 10,000 — 1/TC Rubber-IV w/Armor 16.59 .653 .304 48 50.0 40 80 15,000 — 11.56 .455 2/TC, GS Rubber-IV w/Armor 19.05 .750 .370 48 50.0 40 80 15,000 — PE 2.95 .116 1/TC PE-111 4.67 .184 0.21 53.5 28.5 55 80 1900 Use RG58 PIB 4.7 .185 1/BC PVC-I 6.35 .250 .044 50 27.0 40 80 1500 Use RG58 PIB 7.24 .285 1/BC PVC-I 10.29 .405 .106 51 31.0 40 80 2000 Use RG213 PIB 7.24 .285 1/BC PVC-I w/Armor 11.81 .465 .141 51 29.0 40 80 2000 Use RG215 PE 9.4 3.70 None Lead 11.94 .470 .390 51 30.0 55 80 6000 — PE 11.56 .455 1/BC PVC-I 15.88 .625 .224 71 21.5 40 80 5200 Use RG31B PE 11.68 .460 1/BC PVC-IIA 16 .630 .224 75 20.6 40 80 6500 Use RG34B PE 11.68 .460 1/BC PVC-IIA 16 .630 .224 75 20.6 40 80 6500 Use up to 1000 MHz PE 11.68 .460 1/BC PVC-II w/Armor 23.57 .928 .525 71 21.5 40 80 10,000 Use RG35B PE 1/BC PVC-IIA w/Armor .525 75 20.6 40 80 10,000 Use RG35B Rubber-C 11.68 .460 11.68 .460 23.11 .910 3.56 .140 4.98 .196 4.98 .196 4.98 .196 Rubber-IV PE Dielectric Material DOD Number/Type of Shielding Braids Jacket Material O.D. Weight (lb/ft) PE,2 Cores 9.65 .380 2/Individual Inner Common Outer BC PVC-IIA w/Armor 25.48 1.003 19.81 .780 Rubber-E 7.32 .288 2/TC Rubber-IV Rubber-E 7.32 .288 1/TC Rubber-D 11.56 .455 Rubber-D PE PE Rubber-C Rubber-C Rubber-C 1/BC PVC-IIA 1/BC PVC-I 1/TC PE-III 2/TC PE-III 2/TC PE-III 2/TC Rubber IV 23.57 .928 23.57 .928 29.97 1.180 5.33 .210 7.92 .312 7.92 .312 10.67 .420 6.35 .250 1/TC Rubber-IV 4.98 .196 2/SC PVC-II Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 .525 75 20.6 40 80 10,000 .805 69 22.0 40 80 13,000 Unarmored: see RG164 Use up to 1000 MHz .040 52.5 38.0 55 80 750 — .110 52.5 38.0 55 80 1000 — .100 72.5 28.6 55 80 1000 — .150 72.5 28.0 40 80 1000 — 10.8 .425 .150 67.5 27.6 40 80 3000 — 8.69 .342 .050 78 20.0 40 80 2700 Use RG222 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 287 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 43 54 54A 55 55A 55B 56 57 57A 58 58A 58B 58C 59 59A 59B 60 62 62A 62B 63 63A 63B 64 64A 65 288 Inner Conductor 2 Cond. 2.17 .0855 7/0.72 BC .0285 1.21 .0477 7/0.4 BC .0159 1.16 .0456 7/0.39 BC .0152 0.81 BC .0320 .0.89 SC .0350 0.81 SC .0320 1.49 .0585 19/0.3 BC .0117 2 Cond. 2.17 .0855 7/0.72 BC .0285 2 Cond. 2.17 .0855 7/0.72 BC .0285 0.81 BC .0320 0.9 .0355 0.81 BC .0320 0.9 .0355 19/0.8 TC .0071 0.64 CCS .0253 0.64 CCS .0253 0.58 CCS .0230 1.29 Str. C .0508 0.64 CCS .0253 0.64 CCS .0253 0.61 .0240 7/0.2 CCS .0080 0.64 CCS .0253 0.64 BC .0253 0.64 CCS .0253 1.49 .0585 19/0.3 TC .0117 1.49 .0585 19/0.3 TC .0117 0.2 [.0080] Formex-F 3.25 [.1280] Dia. Helix Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments — 95 17.6 40 80 1500 Use RG57 6.99 .275 .045 58 27.0 40 80 2500 Use RG54A PE-III 6.22 2.45 .041 58 26.5 55 80 3000 Use up to 1000 MHz 2/TC PE-III .032 53.5 28.5 55 80 1900 Use RG55B 2/SC PVC-IIA .034 50 30.8 40 80 1900 2/TC PE-IIIA 5.08 .200 5.08 .200 5.08 .200 .033 53.5 28.5 55 80 1900 Use RG223 Use up to 1000 MHz 7.82 .308 2/BC PVC-I 13.59 .535 .243 48 50.0 40 80 8000 — PE 11.99 .472 1/TC PVC-I 15.88 .625 .225 95 17.0 40 80 3000 Balanced Line Parallel PE 11.99 .472 1/TC PVC-IIA 15.88 .625 .225 95 17.0 40 80 3000 Balanced Line Parallel PE 1/TC PVC-I 53.5 28.5 40 80 1900 Use RG58B 1/TC PVC-I .029 52 28.5 40 80 1900 1/TC PVC-IIA 4.95 .195 4.95 .195 4.95 .195 .029 PE 2.95 .116 2.95 .116 2.95 .116 .029 53.5 28.5 40 80 1900 Use RG58C Use up to 1000 MHz PE 2.95 .116 1/TC PVC-IIA 4.95 .195 .029 50 30.8 40 80 1900 Extra Flexible Version RG58B PE 1/BC PVC-I .032 73 21.0 40 80 2300 Use RG59B 1/BC PVC-IIA .032 73 21.0 40 80 2300 1/BC PVC-IIA .032 75 20.6 40 80 2300 Use RG59B Use up to 1000 MHz 1/BC Rubber-IV .150 50 39.0 40 80 1100 — Air-space PE Air-space PE 3.71 .146 3.71 .146 3.71 .146 6.35 .250 3.71 .146 3.71 .146 Air-space PE Air-space PE Air-space PE Air-space PE Dielectric Material DOD Number/Type of Shielding Braids Jacket Material Rubber-B 11.99 .427 1/BC PVC-I 15.67 .617 PE 4.7 .185 1/BC PVC-I PE 4.52 .178 1/TC PE PE 2.95 .116 2.95 .116 2.95 .116 Rubber-D PE PE O.D. Weight (lb/ft) 1/BC PVC-I 1/BC PVC-IIA 6.15 .242 6.15 .242 6.15 .242 10.8 .425 6.15 .242 6.15 .242 3.71 .146 1/BC PVC-IIA 7.24 .285 7.24 .285 7.24 .285 7.82 .308 7.24 .285 1/BC PVC-I 1/BC PVC-I 1/BC PVC-IIA 2/TC Rubber-IV Rubber-E 7.32 .288 2/TC Rubber-IV PE 7.24 .285 1/BC PVC-I PE PE Rubber-C Rubber-D Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 .038 93 13.5 40 80 750 Use RG62A Low .038 93 13.5 40 80 750 Capacitance 6.15 .242 .038 93 13.5 40 80 750 Extra Flexible RG62A 10.29 .405 10.29 .405 10.29 .405 12.57 .495 10.29 .405 .083 125 10.0 40 80 1000 Use RG63B .083 125 10.0 40 80 1000 Use RG63B .083 125 10.0 40 80 1000 Low Capacitance .225 48 60.0 40 80 10,000 — Capacitance 11.68 .460 .205 48 50.0 40 80 10,000 — 10.29 .405 .096 950 44.0 40 80 1000 High Impedance Video Delay Line Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 65A 71 71A 71B 72 73 74 74A 77A 78A 79 79A 79B 81 82 83 84A 85A 86 87A 88 88A 88B 89 90 93 Inner Conductor .02 [.0080] Formex-F 3.25 [.1280] Dia. Helix 0.64 CCS .0253 0.64 CCS .0253 0.64 CCS .0253 0.64 CCS .0253 1.65 BC .0650 2.59 BC .1020 2.59 BC .1020 1.49 .0585 19/0.3 TC .0117 1.49 .0585 19/0.3 TC .0117 0.64 CCS .0253 0.64 CCS .0253 0.64 CCS .0253 1.59 BC .0625 3.18 BC .1250 2.59 BC .1020 2.65 BC .1045 2.65 BC .1045 2 Cond. 2.17 .0855 7/0.72 BC .0285 2.44 .0960 7/0.81 SC .0320 1.49 .0585 19/0.3 TC .0117 1.49 .0585 19/0.3 TC .0117 1.49 .0585 19/0.3 TC .0117 0.64 CCS .0253 1.53 .0603 7/0.51 SC .0201 5.08 .2000 19/1.02 BC .0400 Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .096 950 44.0 40 80 1000 High Impedance Video Delay Line .046 93 13.5 40 80 750 Use RG71B .046 93 13.5 55 80 750 Use RG71B .046 93 13.5 55 80 750 .169 150 7.8 40 80 750 .031 25 61.8 55 80 1000 Low Capacitance Low Capacitance Low Impedance .310 52 29.5 40 80 5500 Use RG224 2/BC Copper Braid PVC-II w/Armor PVC-IIA w/Armor 6.22 .245 6.22 .245 6.22 .245 16 .630 4.45 .175 15.32 .603 15.32 .603 .310 52 29.5 40 80 5500 Use RG224 7.32 .288 2/TC PVC-IIA 11.43 .450 .195 48 50.0 40 80 8000 Peak — Rubber-E 7.32 .288 1/TC PVC-IIA 10.67 .420 .149 48 50.0 40 80 8000 Peak — Air-space PE Air-space PE Air-space PE Magnesium Oxide G Magnesium Oxide G 7.24 .285 7.24 .285 7.24 .285 8.15 .321 16.51 .650 6.1 .240 17.27 .680 17.27 .680 1/BC PVC-I w/Armor PVC-I w/Armor PVC-IIA w/Armor Copper Tube Copper Tube 11.76 .463 11.76 .463 11.76 .463 8.26 .325 19.05 .750 10.29 .405 25.4 1.000 39.75 1.565 .136 — 10.0 40 80 1000 .130 .125 10.0 40 80 1000 .136 .125 10.0 40 80 1000 Low Capacitance Low Capacitance Low Capacitance .172 50 37.0 250 3000 — .698 50 36.0 250 5000 — Dielectric Material DOD Number/Type of Shielding Braids Jacket Material PE 7.24 .285 1/BC PVC-IIA 10.29 .405 Air-space PE Air-space PE Air-space PE Air-space PE 2/TC PVC-I 2/TC PE-III 2/TC PE-IIIA 1/BC PVC-I 2/BC PE 3.71 .146 3.71 .146 3.71 .146 11.68 .460 2.95 .116 9.4 .370 9.4 .370 Rubber-E PE PE PE PE PE 2/BC 1/BC 1/BC None None 1/BC PVC-I 1/BC 1/BC PVC-IIA w/Lead Sheath PVC-IIA w/Lead Armor O.D. Weight (lb/ft) .120 35 44.0 40 80 2000 1.325 75 20.6 40 80 10,000 2.910 75 20.6 40 80 10,000 Low Impedance RG35B with Special Armor RG84A with Special Armor 7.62 .300 x 16.51 .100 .650 200 7.8 55 80 10,000 Twin Lead PE 7.62 .300 x 16.51 .650 None None PTFE 7.11 .280 2/SC FG Braid-V 10.8 .425 .180 50 29.4 55 250 5000 Use RG225 Rubber-E 7.32 .288 4/TC PVC-I 13.08 .515 .211 48 50.0 40 80 10,000 — Ruber-E 7.32 .288 4/TC PVC-IIA 13.08 .515 .211 48 50.0 40 80 10,000 — Rubber-E 7.32 .288 4/TC Rubber-IV 14.35 .565 .238 48 50.0 40 80 10,000 — Air-space PE 7.24 .285 1/BC PVC-I 16.05 .632 .195 125 10.0 40 80 1000 Low Capacitance PE 4.95 .195 3/SC, GS, SC PVC-IIA 10.8 .425 — 50 30.8 40 80 3000 Excellent Shielding Taped PTFE 14.55 .573 1/BC FG Braid-V 18.03 .710 .475 50 29.4 55 250 10,000 Use RG211A Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 289 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 94 94A 100 101 102 108 108A 111 111A 114 114A 115 115A 116 117 117A 118 118A 119 120 122 124 125 126 290 Inner Conductor 2.86 .1125 19/0.57 SC .0225 3.23 .1270 19/0.65 SC .0254 1.87 .0735 19/0.37 BC .0147 1.63 BC .0641 2 Cond. 2.05 BC .0808 2 Cond. 0.96 .0378 7/0.32 TC .0126 2 Cond. 0.96 .0378 7/0.32 TC .0126 2 Cond. 1.16 .0456 7/0.39 BC .0152 2 Cond. 1.16 .0456 7/0.39 BC .0152 0.18 CCS .0070 0.18 CCS .0070 2.13 .0840 7/0.71 SC .0280 2.13 .0840 7/0.71 SC .0280 2.44 .0960 7/0.81 SC .0320 4.78 BC .1880 4.78 BC .1880 4.78 BC .1880 4.78 BC .1880 2.59 BC .1020 2.59 BC .1020 0.76 .0300 7/0.13 TC .0050 0.64 TCCS .0253 0.4 CCS .0159 1.55 .0609 7/0.52 HR .0203 Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .270 50 29.4 55 250 7000 Use RG226 12.7 .500 .445 50 29.4 55 250 7000 Use RG226 PVC-I 6.15 .242 .046 35 44.0 40 80 2000 Use up to 1000 MHz 1/TC — 14.94 .588 — 75 — — — — — 1/TC — 27.64 1.088 — 140 — — — — PE 2.01 .079 Each 1/TC PVC-II 5.97 .235 .032 78 19.6 40 80 1000 Use RG108A PE 2.01 .079 Each 1/TC PVC-IIA 5.97 .235 .032 78 19.6 40 80 1000 Balanced Line PE 7.24 .285 2/TC PVC-II w/Armor 12.14 .478 .146 95 16.0 40 80 1000 Use RG111A PE 7.24 .285 2/TC PVC-IIA w/Armor 12.14 .478 .146 95 16.0 40 80 1000 Use RG22B w/Armor Air-space PE Air-space PE 7.24 .285 7.24 .285 1/BC PVC-I .087 185 6.5 40 80 1000 Use RG114A 1/BC PVC-IIA 10.29 .405 10.29 .405 .087 185 6.5 40 80 1000 Low Capacitance Taped PTFE 6.35 .250 2/BC FG Braid-V 9.53 .375 .148 50 29.4 55 250 5000 Use RG115A Taped PTFE 6.48 .255 2/BC FG Braid-V 10.54 .415 .180 50 29.4 55 250 5000 Extra Flexible RG225 PTFE 7.11 .280 2/SC FG Braid-V w/Armor 12.7 .475 .198 50 29.4 55 250 5000 Use RG227 PTFE 1/BC 18.54 .730 18.54 .730 19.81 .780 19.81 .780 11.81 .465 13.28 .523 50 29.4 55 250 7000 Use RG211A .641 50 29.4 55 250 7000 Use RG211A .682 50 29.4 55 250 7000 Use RG228A .682 50 29.4 55 250 7000 Use RG228A .225 50 29.4 55 250 6000 2/BC FG Braid-V FG Braid-V FG Braid-V w/Armor FG Braid-V w/Armor FG Braid-V FG Braid-V .641 PTFE 15.75 .620 15.75 .620 15.75 .620 15.75 .620 8.43 .332 8.43 .332 .282 50 29.4 55 250 6000 Use up to 1000 MHz RG119 w/Armor PE 2.44 .096 1/TC PVC-IIA 4.06 .160 .016 50 29.4 40 80 1900 Use up to 1000 MHz Taped PTFE Air-space PE 3.43 .135 11.68 .460 1/TC FG Braid-V .210 73 20.3 55 250 2300 Use RG140 1/BC PVC-IIA 6.1 .240 15.24 .600 .180 150 7.8 40 80 2000 Low Capacitance PTFE 4.7 .185 1/HR FG Braid-V 7.11 .280 .070 50 29.4 55 250 3000 High Loss Cable Dielectric Material DOD Number/Type of Shielding Braids Jacket Material Taped PTFE 7.42 .292 2/BC FG Braid-V 11.3 .445 Taped PTFE 9.4 .370 2/BC FG Braid-V PE 3.71 .146 1/BC Rubber — Rubber PTFE PTFE PTFE PTFE Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 1/BC 1/BC 1/BC 2/BC O.D. Weight (lb/ft) Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 130 131 133 133A 140 141 141A 142 142A 142B 143 143A 144 145 146 147 148 149 150 156 157 158 159 160 161 164 Inner Conductor 2 Cond. 2.17 .0855 7/0.72 BC .0285 2 Cond. 2.17 .0855 7/0.72 BC .0285 0.72 BC .0285 0.64 BC .0253 0.64 SCCS .0250 0.91 SCCS .0359 0.99 SCCS .0390 0.91 SCCS .0359 0.99 SCCS .0390 0.99 SCCS .0390 1.45 SCCS .0570 1.5 SCCS .0590 1.36 .0537 7/0.45 SCCS .0179 2 Cond. 1.83 BC .0720 0.18 CCS .0070 6.35 BC .2500 2.17 .0855 7/0.72 BC .0285 1.22 .048 7/0.4 TC .0159 1.22 .048 7/0.4 TC .0159 2.17 .0855 7/0.72 TC .0285 2.55 .1005 19/0.51 TC .0201 5.05 .1988 37/0.72 TC .0284 0.81 SC .0320 4 Cond. 1.8 .071 19/0.36 2TC, 2BC .0142 0.3 .012 7/0.1 S Cad. BR .004 2.65 BC .1045 Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .220 95 17.0 40 80 3000 RG57 w/ Twisted Cond. 17.35 .683 .290 95 17.0 40 80 3000 Armored RG130 .094 95 16.2 40 80 4000 Use RG133A Dielectric Material DOD Number/Type of Shielding Braids Jacket Material PE 11.99 .472 1/TC PVC-I 15.88 .625 PE 11.99 .472 1/TC PVC-I w/Armor PE 1/BC PVC-I PTFE 7.24 .285 7.24 .285 3.71 1.46 2.95 .116 2.95 .116 2.95 .116 2.95 .116 2.95 .116 4.7 .185 4.7 .185 Air-space PE O.D. Weight (lb/ft) 2/SC FG 2/SC FEP 2/SC FG Braid-V 1/SC FG Braid-V 10.29 .405 10.29 .405 5.92 .233 4.83 .190 4.83 .190 4.95 .195 4.95 .195 4.95 .195 8.26 .325 8.26 .325 7.24 .285 Copper Tube FG Braid-V Air-space PTFE — 1/BC PE PE 7.24 .285 23.11 .910 PTFE PE PTFE PTFE PTFE PTFE 1/BC PVC-IIA 1/SC FG Braid-V 1/SC FG Braid-V 1/SC FG Braid-V 2/SC FG Braid-V .094 95 16.2 40 80 4000 .056 75 19.5 55 250 2300 95 Ohm Version RG8 See RG302 for FEP Jacket .036 50 29.4 55 250 1900 Use RG141A .036 50 29.4 55 250 1900 See RG303 for FEP Jacket .047 50 29.4 55 250 1900 Use RG142A .047 50 29.4 50 250 1900 .047 50 29.4 55 250 1900 See RG142B for FEP Jacket Standard Center Cond. Available .114 50 29.4 55 250 3000 Use RG143A .109 50 29.4 55 250 3000 See RG304 for FEP Jacket 10.41 .410 .137 75 19.5 55 250 5000 High Temp. RG11A Lead/Tar — — 75 14.6 — — — 1/BC FG Braid-V .108 190 6.0 55 200 1000 1/BC PVC-I w/Armor 9.53 .375 49.2 1.937 — 52 29.5 40 80 14,000 Low Capacitance RG19U w/Armor 7.24 .285 1/SC PVC-I w/Armor 20.32 .800 — 52 29.5 40 80 4000 — PE 7.24 .285 1/BC PVC-IIA 10.29 .405 .105 75 20.6 40 80 5000 Use RG391 PE 7.24 .285 1/BC PVC-IIA w/Armor 11.76 .463 .112 75 20.6 40 80 5000 Use RG392 PE and Cond. PE 7.24 .285 3/TC, GS, TC PVC-IIA 13.72 .540 .211 50 32.0 40 80 10,000 Triaxial Pulse Cable PE and Cond. PE 11.56 .455 3/TC, GS, TC PVC-IIA 18.42 .725 .317 50 38.0 40 80 15,000 Triaxial Pulse Cable PE and Cond. PE 11.56 .455 3/TC, GS, TC PVC-IIA 18.42 .725 .380 25 78.0 40 80 15,000 Triaxial Pulse Cable Taped PTFE 2.95 .116 1/SC FG Braid-V 4.95 .195 .035 50 29.4 55 250 1900 Use RG141 PE 8.18 .322 1/BC PVC-I 26.8 1.055 — 125 12.0 40 80 3000 4 Cond. Balanced Line PTFE 1.45 .057 1/SC Nylon 2.08 .082 .015 70 20.0 60 120 1000 Miniature PE 17.27 .680 1/BC PVC-IIA 22.1 .870 .490 75 20.6 40 80 10,000 RG35B without Armor PTFE PTFE PTFE Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 291 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 165 166 174 174A 176 177 178 178A 178B 179 179A 179B 180 180A 180B 181 182 183 185 292 Inner Conductor 2.44 .0960 7/0.81 SC .0320 2.44 .0960 7/0.81 SC .0320 0.48 .0189 7/0.16 CCS .0063 0.48 .0189 7/0.16 CCS .0063 3.43 .135 Helix over Magnetic Core 4.95 BC .195 0.3 .0120 7/0.1 SCCS .0040 0.3 .0120 7/0.1 SCCS .0040 0.3 .0120 7/0.1 SCCS .0040 0.3 .0120 7/0.1 SCCS .0040 0.3 .0120 7/0.1 SCCS .0040 0.3 .0120 7/0.1 SCCS .0040 0.3 .0120 7/0.1 SCCS .0040 0.3 .0120 7/0.1 SCCS .0040 0.3 .0120 7/0.1 SCCS .0040 2 Cond. 1.21 .0477 7/0.4 BC .0159 2 of 19/0.36 BC .0142 2 of 19/0.17 TC .0066 6.38 BC .2510 0.08 [.0031] Mag. Wire Helix on PE Core Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .121 50 29.4 55 250 5000 RG225 w/One Braid 11.68 .460 .144 50 29.4 55 250 5000 RG165 w/ Armor PVC 2.54 .100 .008 50 30.8 40 80 1500 Miniature Data Transmission 1/TC PVC-IIA 2.54 .100 .008 50 30.8 40 80 1500 Miniature Data Transmission 7.24 .285 1/Magnet Wire PVC-I 10.29 .405 .120 2240 49.0 40 80 5000 — PE 17.27 .680 2/SC PVC-IIA 22.73 .895 .470 50 30.8 40 80 11,000 High Frequency RG218 PTFE 0.91 .036 1/SC KEL-F 1.83 .072 .0054 50 29.4 40 150 1000 Use RG178B PTFE 0.86 .034 1/SC KEL-F 1.83 .072 .005 50 29.4 40 150 1000 Use RG178B PTFE 0.86 .034 1/SC FEP-IX 1.83 .072 .0054 50 29.4 55 200 1000 High Strength Cond. Available PTFE 1.45 .057 1/SC KEL-F 2.54 .100 .010 70 20.4 55 150 1200 Use RG179B PTFE 1.6 .063 1/SC KEL-F 2.54 .100 .010 75 19.5 40 150 1200 Use RG179B PTFE 1.6 .063 1/SC FEP-IX 2.54 .100 .010 75 19.5 55 200 1200 High Strength Cond. Available PTFE 2.62 .103 1/SC KEL-F 3.56 .140 .019 93 15.4 40 150 1500 Use RG180B PTFE 2.59 .102 1/SC KEL-F 3.56 .140 .019 95 15.4 40 150 1500 Use RG180B PTFE 2.59 .102 1/SC KEP-IX 3.56 .140 .019 95 15.4 55 200 1500 High Strength Cond. Available PVS-IIA 16.25 .640 .198 125 12.0 40 80 3500 Balanced Line PVC-IIA each PVC-I overall 26.8 1.055 — 125 each 12.0 each 40 80 2300 3000 Special 4 Coaxial None 19.05 .750 .380 50 23.0 40 80 1800 See Times AM-5034S PVC-IIA 7.16 .282 — 2000 — 40 80 — Delay Line Cable Dielectric Material DOD Number/Type of Shielding Braids Jacket Material PTFE 7.24 .285 1/SC FG Braid-V 10.41 .410 PTFE 7.24 .285 1/SC FG Braid-V w/Armor PE 1.52 .060 1/TC PE 1.52 .060 PE PE 4 Cores PE PS Helix Air-Space PE 2/Individual Inner Common Outer BC 2/8.43 Each Core .332 1/BC 2/3.71 Overall Shield .146 1/BC 16.05 AI. Tube .632 5.33 .210 4.78 .188 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 1/Magnet Wire O.D. Weight (lb/ft) Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 187 187A 188 188A 189 190 191 192 193 194 195 195A 196 196A 197 198 199 200 209 210 211 211A 212 213 Inner Conductor Dielectric Material 0.3 .0120 PTFE 7/0.1 SCCS .0040 0.3 .0120 PTFE 7/0.1 SCCS .0040 0.51 .0201 PTFE 7/0.17 SCCS .0067 0.51 .0201 PTFE 7/0.17 SCCS .0067 6.38 BC PS Helix .2510 1.49 .0585 Rubber H, J 7/0.3 TC .0117 12.32 TC Braid Rubber H, J, H .485 26.8 GS Tube Butyl Rubber 1.055 TC Braid 26.8 GS Tube Silicone 1.055 TC Braid Rubber 26.8 GS Tube Silicone 1.055 TC Braid Rubber 0.3 .0120 PTFE 7/0.1 SCCS .004 0.3 .0120 PTFE 7/0.1 SCCS .004 0.3 .0120 PTFE 7/0.1 SCCS .004 0.3 .0120 PTFE 7/0.1 SCCS .004 7.62 BC PS Helix .300 2.9 BC PS Helix .1140 5.31 BC PS Helix .209 OD-10.29 .405 ID-7.65 BC Tube PS Helix .301 4.8 .189 Air-Space 19/0.96 SC PTFE .0378 0.64 SCCS Air-Space .0253 PTFE 4.83 BC PTFE .1900 4.83 BC PTFE .1900 1.44 SC PE .0556 2.26 .0888 PE 7/0.75 BC .0296 Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .010 75 19.5 55 250 1200 Use RG179B 2.67 .105 .010 75 19.5 55 250 1200 Use RG179B PTFE 2.67 .105 .011 50 29.4 55 250 1200 Use RG316 1/SC PTFE 2.67 .105 .011 50 29.4 55 250 1200 Use RG316 16.05 .632 2/SC PE-IIIA 22.23 .875 .570 50 23.0 55 80 3500 Use RG389 9.65 .380 3/TC, GS, TC Neoprene VIII 17.78 .700 .353 50 50.0 55 80 15,000 — 27.05 1.065 Neoprene VIII 25 85.0 55 80 15,000 — — — Rubber w/ Al. Armor 37.08 1.460 55.88 2.200 53.34 2.100 49.4 1.945 1.469 — 3/TC, GS, GS 3/TC, GS, GS 3/TC, GS, GS 3/TC, GS, GS 2.59 .102 1/SC PTFE 2.59 .102 1/SC 0.86 .034 DOD Number/Type of Shielding Braids Jacket Material 1.52 .060 1/SC PTFE 2.67 .105 1.52 .060 1/SC PTFE 1.52 .060 1/SC 1.52 .060 O.D. Weight (lb/ft) — 12.5 175.0 55 80 — 12.5 159.0 55 80 — 12.5 159.0 55 80 15,000 Peak 30,000 Peak 30,000 Peak 3.68 .145 .020 95 15.4 55 250 1500 Use RG180B PTFE 3.68 .145 .020 95 15.4 55 250 1500 Use RG180B 1/SC PTFE 1.83 .072 .006 50 29.4 55 250 1000 Use RG178B 0.86 .034 1/SC PTFE 1.83 .072 .006 50 29.4 55 250 1000 Use RG178B 19.25 .758 10.69 .421 19.25 .758 22.23 [.875] OD Al. Tube 12.7 [.500] OD Al. Tube 22.23 [.875] OD Al. Tube None .500 50 22.0 55 80 .155 70 16.0 55 80 .435 70 16.0 55 80 2400 Peak 1300 Peak 2400 Peak — PE 22.23 .875 15.24 .600 25.78 1.015 PE 44.83 1.765 .900 70 16.0 55 80 4600 Peak — — — 37.39 41.28 [1.625] 1.472 OD Al. Tube Rubber Rubber PE — — — 12.7 .500 2/SC SR and Polyester-IV 18.42 .725 .432 50 25.0 55 150 3200 Low Loss RG211A 3.71 .146 15.75 .620 15.75 .620 4.7 .185 1/SC FG Braid-V .040 93 13.5 55 250 750 1/BC FG Braid-V .641 50 29.4 55 250 7000 1/BC FG Braid-V .641 50 29.4 55 250 7000 2/SC PVC-IIA 6.15 .242 18.54 .730 18.54 .730 8.43 .332 .083 50 29.4 40 80 3000 High Temp. Low Capacitance High Temp. High Power High Temp. High Power Use up to 10,000 MHz 7.24 .285 1/BC PVC-IIA 10.29 .405 .099 50 30.8 40 80 5000 Use up to 1000 MHz Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 293 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 228A 229 230 231 232 233 234 235 294 Inner Conductor 2.26 .0888 7/0.75 SC .0296 2.26 .0888 7/0.75 .0296 1.21 .0477 7/0.75 BC .0159 2.7 BC .106 4.95 BC .195 4.95 BC .195 6.6 BC .260 6.6 BC .260 1.41 .0556 High Res. Wire 0.89 SC .035 2.609 BC .106 2.38 .0936 7/0.79 SC .0312 3.23 .1270 19/0.65 SC .0254 2.38 .0936 7/0.79 SC .0312 4.83 BC .1900 4.83 BC .1900 2.44 .0960 7/0.81 SC .032 5.05 .1988 37/0.72 TC .0284 OD-4.11 .162 ID-2.84 BC .112 7.62 BC .300 OD-15.01 BC .591 ID-12.22 .481 OD-29.39 BC 1.570 ID-25.78 1.015 2.16 .0852 7/0.72 .0284 Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .126 50 30.8 40 80 5000 Use up to 10,000 MHz 11.76 .463 .121 50 30.8 40 80 5000 Armored RG213 PVC-IIA 10.8 .425 .114 75 20.6 40 80 5000 Use up to 1000 MHz PVC-IIA .201 50 30.8 40 80 7000 .460 50 30.8 40 80 11,000 .585 50 30.8 40 80 11,000 .740 50 30.8 40 80 14,000 .925 50 30.8 40 80 14,000 Use up to 1000 MHz Use up to 1000 MHz Armored RG218 Use up to 1000 MHz Armored RG220 Dielectric Material DOD Number/Type of Shielding Braids Jacket Material PE 7.24 .285 2/SC PVC-IIA 10.0 .425 PE 7.24 .285 1/BC PVC-IIA w/Armor PE 7.24 .285 2/BC PE 2/BC PE 9.4 .370 17.27 .680 17.27 .680 23.11 .910 23.11 .910 PE PE O.D. Weight (lb/ft) 1/BC PVC-IIA 1/BC PVC-IIA w/Armor 13.84 .545 22.1 .870 23.57 .928 28.45 1.120 29.92 1.178 4.7 .185 2/SC PVC-IIA 8.43 .332 .087 50 30.8 40 80 3000 High Attenuation 2/SC PVC-IIA 50 30.8 40 80 1900 2/BC PVC-IIA w/Armor 5.36 .211 15.32 .603 .034 PE 2.95 .116 9.4 .370 .310 50 30.8 40 80 7000 Use up to 10,000 MHz Armored RG217 PTFE 7.24 .285 2/SC FG Braid-V 10.92 .430 .180 50 29.4 55 250 5000 See RG393 for FEP Jacket Taped PTFE 9.4 .370 2/SC FG Braid-V 12.7 .500 .445 50 29.4 55 250 7000 — PTFE 7.24 .285 2/SC FG Braid-V w/Armor 12.40 .488 .198 50 29.4 55 250 5000 Armored RG225 PTFE 1/BC 20.02 .788 20.02 .788 50 29.4 55 250 7000 1/BC FG Braid-V w/Armor FG Braid-V w/Armor .682 PTFE 15.75 .620 15.75 .620 .682 50 29.4 55 250 7000 Armored RG211 Armored RG211A PTFE 7.24 .285 1/SC FG Braid-V w/Armor 11.68 .460 .144 50 29.4 55 250 5000 Use RG166 Rubber-D 11.56 .455 3/TC, GS, GS Rubber-IV 18.8 .740 — 25 100.0 40 80 15,000 — Foam PE 11.43 .450 12.7 .500 OD Al. Tube None 12.7 .500 .118 50 25.0 55 80 5000 Peak RG331 for Jacketed Cable PE Helix 19.25 .758 22.23 .875 OD Al. Tube PE-IIIA 28.07 1.015 .570 50 22.0 50 80 2400 Peak — PS Helix 37.39 1.472 41.28 1.625 OD Al. Tube PE-IIIA 44.83 1.765 1.050 50 22.0 55 80 4700 Peak — PS Helix 70.49 2.775 79.38 3.125 OD Al. Tube PE-IIIA 83.69 3.295 3.110 50 22.0 55 80 8700 Peak — Taped PTFE 5.72 .255 2/SC SIL/DAC VI 11.43 .450 .160 50 29.5 55 250 5000 RG115A 235 w/VI Jacket PE PE PE Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 1/BC PVC-IIA 1/BC PVC-IIA w/Armor Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 263 264 .165 50 24.0 55 80 — — 12.7 .500 15.24 .600 — — — — — — — — — — Max. Operating Voltage (Volts RMS) 1300 Peak 1300 Peak — — 41.28 1.625 OD Al. Tube None 41.28 1.625 .930 50 22.0 55 80 4700 — — — — — — — — — — Use RG233 72.39 2.850 79.38 3.125 OD Al. Tube None 79.3 3.125 2.700 50 22.0 55 80 8700 Peak — — 10.69 .421 10.69 .421 19.25 .758 19.25 .758 — 12.7 [.500] OD Al. Tube 12.7 [.500] OD Al. Tube 22.23 [.875] OD Al. Tube 22.23 [.875] OD Al. Tube — — — — — .118 75 15.5 55 80 .148 75 15.5 55 80 .348 75 15.2 55 80 .418 75 15.2 55 80 — 1200 Peak 1200 Peak 2200 Peak 2200 Peak Use RG234 PE-IIIA — 12.7 .500 15.24 .600 22.23 .875 25.78 1.015 37.39 1.472 41.28 1.625 OD Al. Tube None 41.28 1.625 .948 75 15.0 55 80 4300 Peak — 37.39 1.472 41.28 1.625 PE-IIIA 44.83 1.765 1.068 75 15.0 55 80 4300 Peak — 72.39 2.850 79.38 3.125 OD Al. Tube None 79.38 3.125 2.395 75 15.0 55 80 8500 Peak — 72.39 2.850 79.38 3.125 OD Al. Tube PE-IIIA 32.95 2.805 .175 75 15.0 55 80 8500 Peak — 11.58 .456 11.58 .456 21.16 .833 21.16 .833 13.46 [.530] OD Al. Tube 13.46 [.530] OD Al. Tube 24.21 [.953] OD Al. Tube 24.21 [.953] OD Al. Tube None .225 50 24.0 55 80 1000 — .655 50 24.0 55 80 1000 — .555 50 24.0 55 80 1860 — None 13.46 .530 16.64 .655 27.94 1.100 24.21 .953 .550 50 24.0 55 80 1860 — 21.16 .833 24.21 .953 OD Al. Tube None 24.21 .953 1.200 50 24.0 55 80 1860 — 41.2 1.622 45.36 1.786 OD Al. Tube None 45.36 1.786 1.380 50 24.0 55 80 3640 — 41.2 1.622 45.36 1.786 OD Al. Tube PE 48.92 1.926 .100 50 24.0 55 80 3640 — 8.08 .318 8.08 .318 10.69 .421 4.47 .176 e/core 9.91 [.390] OD Al. Tube 9.91 [.390] OD Al. Tube None .140 50 24.0 55 80 697 — .170 50 24.0 55 80 697 — .336 50 21.5 40 250 1300 Peak — .327 36.8 41.0 40 80 2000 Use RG264C Dielectric Material DOD Number/Type of Shielding Braids Jacket Material 4.11 BC PS Helix .1620 4.11 BC PS Helix .1620 — — — — OD-15.01 BC .591 PS Helix ID-12.22 BC .481 — — OD-29.39 1.157 PS Helix ID-25.78 1.0150 — — 2.59 BC PS Helix .102 2.59 BC PS Helix .102 4.78 BC PS Helix .1880 4.78 BC PS Helix .1880 OD-9.5 BC .3740 PS Helix ID-6.96 27.40 OD-9.5 BC .3740 PS Helix ID-6.96 27.40 18.59 BC .732 PS Helix 16.05 .632 18.59 BC .732 PS Helix 16.05 .632 4.24 BC PE Tubes .1670 4.24 BC PE Tubes .1670 7.9 BC PE Tubes .3110 7.9 BC PE Tubes .3110 OD-7.9 SC .3110 PTFE Tubes ID-6.48 .2550 OD-15.39 .6060 PS Tubes ID-1.23 BC .4860 OD-15.39 .6060 ID-1.23 BC Tube PS Tubes .4860 2.92 BC Tube PTFE Tubes .1150 2.92 BC Tube PE Tubes .1150 4.37 BC Air-Space .1720 PTFE 4 Cond. 19/0.36 .0142 PE 2 TC, 2 BC 10.69 .421 10.69 .421 — — 12.7 [.500] OD Al. Tube 12.7 [.500] OD Al. Tube — — None PE-IIIA 36.07 1.420 Inner Conductor Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 None PE-IIIA None PE PE Al. Tube None 9.91 .390 11.43 .450 12.7 .500 2 TC, 2 BC BC Overall PVC-IIA 19.05 .750 PE-IIIA Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) 50 24.0 55 80 .195 O.D. Weight (lb/ft) Dimensions are in millimeters over [inches] www.amp.com/communications/com Comments — — Use RG197/U Use RG232/U — — — — Specifications subject to change. 295 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) RG/U Type Cable DOD Number/Type of Shielding Braids Jacket Material O.D. Weight (lb/ft) Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments 267 9.02 BC Tube .3550 PS Helix 268 4.09 BC .1610 ID-7.29 .2870 OD-9.09 BC .3580 Tube OD-7.29 .2870 ID-9.09 BC .3580 Tube ID-14.94 .5880 OD-17.48 BC .6880 Tube ID-14.94 .5880 OD-17.48 BC .6880 Tube 0.64 .0250 19/0.13 SCCS .0050 2.91 BC .1144 4.8 .1890 19/0.96 SC .0378 0.64 SC .0253 1.49 .0585 19/0.3 SC .0117 5.59 BC .220 2.9 BC .1140 OD-10.92 .4300 ID-9.14 BC .3600 Tube 5 BC .1970 OD-8.46 .3330 ID-5.64 BC .2221 Tube OD-20.83 .8200 ID-18.8 CCS .7400 Tube 10.92 BC Tube .4300 2.69 BC .106 PE Helix PE Helix 20.19 .795 Corrugated BC Tube None 23.53 1.005 .430 50 22.2 55 80 44 KW Peak — PE Helix 20.19 .795 Corrugated BC Tube None 23.53 1.005 .875 50 22.2 55 80 44 KW Peak — PE Helix 40.08 1.578 Corrugated BC Tube None 46.48 1.830 .875 50 22.3 55 80 145 KW Peak — PE Helix 40.08 1.578 Corrugated BC Tube None 46.48 1.830 .125 50 22.3 55 80 145 KW Peak — Air-space PTFE 2.79 .110 1/SC FG Braid-V 3.68 .145 .200 75 19.5 55 250 Extra Flex. High Temp. Cable Extra Flex. High Temp. Cable Taped PTFE 8.31 .327 2/SC FEP-IX 11.89 .468 .400 50 25.4 55 200 3000 Low Loss High Frequency Taped PTFE 12.7 .500 2/SC Sil./DAC-VI 19.05 .750 .031 50 25.4 55 150 4000 Low Loss High Power Irradiated PE 2.51 .099 2/SC FEP 5.08 .200 .145 54.5 28.2 40 150 4500 — Rubber-D 7.31 .288 2/SC Sil. 12.07 .475 .410 46 50.0 55 150 8000 — PE Helix Corrugated BC Tube Corrugated BC Tube None 75 15.0 55 80 29 KW — None 25.53 1.005 25.53 1.005 .430 PTFE Helix 20.19 .795 20.19 .795 .720 100 13.0 55 200 22 KW Peak — PE Helix 39.88 1.570 Corrugated BC Tube None 46.48 1.830 .750 75 15.1 55 80 100 KW Peak — PE Helix 39.88 1.570 Corrugated BC Tube None 46.48 1.830 3.000 100 13.5 55 80 73 KW Peak — PE Helix 75.18 2.960 95.25 CCS 3.750 None 95.25 3.750 3.000 50 21.6 40 80 440 KW Peak — PE Helix 75.18 2.960 95.25 CCS 3.750 None 95.25 3.750 1.040 75 14.7 40 80 290 KW Peak — PE Helix 39.88 46.48 [1.8300] PE and 1.570 Corr. BC Tube Flooding Comp. 9.53 1/SC PE-IIIA .375 50.8 2.000 13.84 .545 .160 75 15.1 55 80 100 KW Peak — .160 50 30.8 55 80 7000 Use RG293A 264C 265 266 269 269A 270 270A 279 280 281 282 283 284A 285A 286 287 288 289 292 293 4 Cond. 19/0.36 .0142 2 TC, 2 BC 4 Cond. 1.73 .068 2 BC, 2 TC 17.2 BC Tube .6770 0.29 Cond. Over .0113 3.66 Mag. Core .144 Dielectric Material 4.47 2 TC, 2 BC .176 BC Overall e/core 4.72 2 TC, 2 BC .186 BC Overall e/core 40.08 Copper Clad 1.578 Mild Steel Tube 75 Spiral 7.24 Wound Cond. .285 68 BC & 7 are Insulated Copper Clad — Mild Steel Cor. Tubing 8.89 Corrugated .350 BC Tube 264A 296 Inner Conductor PE PE PE Helix PE PE Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 PUR 19.05 .750 .327 36.8 41.0 40 80 2000 Use RG264C PUR 19.43 .765 — 40 38.4 40 80 2000 Watertight 4 Coax. PE-IIIA 52.58 2.070 .120 50 22.3 40 80 145 KW Peak — PVC-I 10.16 .400 — 1530 53.0 40 80 5000 DC Delay Line Cable 50 ns/ft PE-IIIA 30.23 1.190 .234 50 22.2 40 80 44 KW Peak — None 12.65 .498 .430 50 23.0 55 80 10 KW Peak — Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .205 50 30.8 55 80 7000 Watertight RG217 16 .630 .205 95 16.3 55 80 3000 Use RG294A PE-IIIA 16 .630 .420 95 16.3 55 80 3000 Watertight RG130 1/SC PE-IIIA 22.73 .895 — 50 30.8 55 80 11,000 Watertight RG218 23.01 .906 1/SC Neoprene 30.23 1.190 — 50 36.4 55 80 13,800 — PFTE Helix 20.19 .795 Corrugated BC Tube None 25.53 1.005 .090 50 21.4 55 200 44 KW Peak — PE 2.92 .115 None Foam PE 16.51 .650 .056 — — 55 80 — Buoyant Per MIL-C-22667 PTFE 4.7 .185 1/HR FEP-IX 6.23 .245 .031 50 29.4 55 200 3000 FEP Jacketed RG126 PTFE 1/SC FEP-IX 75 19.5 55 200 2300 1/SC FEP-IX .088 50 29.4 55 200 1900 2/SC FEP-IX 5.11 .201 4.32 .170 7.11 .280 .030 PTFE 3.71 .146 2.95 .116 4.7 .185 — 50 29.4 55 200 300 FEP Jacketed RG140 FEP Jacketed RG141A FEP Jacketed RG143A FEP 39.88 46.48 BC Tube 1.570 1.830 PE-IIIA 50.55 1.990 .545 75 14.4 55 80 2720 — Foam PE 20.35 22.23 AI. Tube .801 .8750 PE-IIIA 25.78 1.015 .070 75 16.5 55 80 5700 Per MIL-C-23806 Foam PE 3.71 .146 2/SC PUR Interlayer PE-IIIA 6.86 .270 .070 75 16.7 55 80 1000 Triax Use to 100 MHz Foam PE 3.71 .146 2/SC PUR Interlayer PE-IIIA 6.86 .270 .060 75 16.7 55 80 1000 Triax Use to 100 MHz PTFE 1.52 .060 1/SC FEDP-IX 2.59 .102 .012 50 29.4 55 200 1200 FEP Jacketed RG188A FEP 11.33 .446 1/TC Neoprene 18.03 .710 — 95 15.4 55 80 10,000 Water Blocked RG/U Type Cable Inner Conductor Dielectric Material DOD Number/Type of Shielding Braids Jacket Material 293A 2.69 BC .106 2 Cond. 2.05 .0808 1 BC, 1 TC 2 Cond. 2.05 .0808 1 BC, 1 TC 4.95 BC .1950 5.97 .2352 37/0.85 SC .0336 OD-9.02 .3550 ID-7.29 BC .2870 Tube 15.32 .6030 7/0.51 CCS .0201 1.55 .0609 7/0.52 HR .0203 0.64 SCCS .0250 0.99 SCCS .0390 1.5 SCCS .0590 OD-10.92 .4300 ID-9.14 .3600 Tube 4.39 BC .1730 0.74 .0290 19/0.15 SC .0058 0.74 .0290 19/0.15 SC .0058 0.51 .0201 7/0.17 SCCS .0067 2 Cond. 2.21 .0870 7/0.74 BC .0290 OD-9.09 BC .3580 Tube ID-7.29 .2870 OD-17.48 BC .6880 Tube ID-14.94 .5580 OD-28.96 1.1400 Corr. BC Tube OD-28.96 1.1400 Corr. BC Tube PE 9.4 .370 1/SC PE-IIIA 13.84 .545 PE 11.99 .472 1/TC PE-IIIA PE 11.99 .472 1/SC PE 17.27 .680 Silicone Rubber 294 294A 295 296 297 298 301 302 303 304 305 306A 307 307A 316 317 318 319 321 322 PTFE O.D. Weight (lb/ft) PE Helix 25.53 20.19 .795 Corr.1.005 BC Tube PE-IIIA 28.58 1.125 .530 50 22.0 55 80 44 KW Peak — PE Helix 46.48 39.88 1.570 Corr.1.830 BC Tube PE-IIIA 50.8 2.000 1.040 50 22.0 55 80 145 KW Peak — None 72.39 2.850 1.210 50 21.7 55 80 320 KW Peak — PE & Flood Comp. 77.22 3.040 1.780 50 21.7 55 80 320 KW Peak — PE Helix — PE Helix — Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 79.39 2.850 Corr. BC Tube 79.39 2.850 Corr. BC Tube Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 297 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) Comments .420 50 25.6 55 80 1480 — 24.89 .980 .320 50 25.6 55 80 1480 — PUR 8.89 .350 .10 50 26.3 55 80 750 Low Loss 2/SC Strip Braids PUR 17.7 .697 .24 50 26.3 55 80 1700 Low Loss 21.34 .840 2/SC Strip Braids PUR 25.65 1.010 .55 50 26.3 55 80 2500 Low Loss Rubber H.J.H. 27.05 1.065 3/TC, GS, TC Neoprene 37.08 1.460 1.469 25 85.0 55 80 20,000 — Rubber H.J.H. 9.65 .380 3/TC, GS, TC Neoprene 17.78 .700 .353 50 50.0 55 80 15,000 — Foam PE — 1/SC — — 50 25.0 — — — 11.43 .450 20.35 .801 20.35 .801 11.43 .450 11.43 .450 20.35 .801 17.17 .676 PE-IIIA 6.15 .242 15.24 .600 22.23 .875 25.78 1.015 12.7 .500 15.88 .625 22.23 .875 20.95 .825 PE-IIIA 15.75 .620 PE-IIIA PE-IIIA Inner Conductor Dielectric Material DOD 323 7.92 BC Tube .312 Foam PE — 324 7.92 BC Tube .312 Foam PE — PE Spline 325 326 327 328 329 2.54 .1000 19/0.51 SC Al. .0200 5.08 .2000 19/1.02 SC Al. .0400 8.13 .3200 19/1.63 SC Al. .0640 12.32 TC Braid .4850 1.49 .0585 19/0.3 TC .0117 Number/Type of Shielding Braids Jacket Material O.D. Weight (lb/ft) 24.89 .980 Corr. BC Tube 24.89 .980 Corr. BC Tube PE & Flood Comp. 26.92 1.060 None 6.6 .260 2/SC Strip Braids PE Spline 13.97 .550 PE Spline 330 SC 331 Foam PE 360 4.11 BC .1620 7.11 BC .2800 7.11 BC .2800 2.49 BC .0980 2.49 BC .0980 4.39 BC .1730 6.17 BC .2430 366 4.06 .1600 Foam PE 367 Corrugated BC Tube PE Helix 369 PE Tubes 377 2.97 BC .1170 2.97 BC .1170 0.72 BC .0285 7.92 BC Tube .3120 4.19 SC Tube .1650 378 18.11 BC Tube .7130 332 333 334 335 336 370 374 376 383 384 385 298 Nom. Imped. (Ohms) RG/U Type Cable 2 Cond. 1.02 .0403 2000 lb. Break 1.29 BC .0508 3.89 SC .1530 Foam PE Foam PE Foam PE Foam PE Foam PE Foam PE 12.7 Al. Tube .500 22.23 Al. Tube .8750 22.23 Al. Tube .8750 12.7 Al. Tube .500 12.7 Al. Tube .500 22.23 Al. Tube .8750 19.05 Al. Tube .7500 13.72 — .540 Corr. BC Tube 12.7 — .5000 Corr. BC Tube 8.08 9.91 Al. Tube .318 .390 8.08 9.91 Al. Tube .318 .390 4.06 None .160 PE-IIIA None PE-IIIA None PE-IIIA None .187 50 25.0 55 80 2500 Jacketed 231 Solid Conductor .466 50 25.0 55 80 4500 Per MIL-C-23806 .548 50 25.0 55 80 4500 Jacketed RG332 .109 75 17.0 55 80 2500 Per MIL-C-23806 .143 75 17.0 55 80 2500 Jacketed RG334 .315 75 17.0 55 80 4000 Per MIL-C-23806 .397 50 25.0 55 80 4000 Per MIL-C-23806 — 50 62.6 55 80 4000 — 132.08 4.590 5.2000 50 21.7 55 80 830 KW Peak — .140 50 24.0 55 80 700 — .100 50 24.0 40 80 700 — — Corr. Al. Tube PE-IIIA PTFE Tubes — None PE Helix — 13.46 Al. Tube .5300 46.48 1.830 Corr. Al. Tube 11.94 .470 9.91 .390 16.51 .650 26.92 1.060 13.36 .530 PE-IIIA 50.8 2.000 .620 50 22.1 55 80 145 KW Peak — PE — Foam PE 16.51 .650 — 100 — 55 80 — Exper. Buoyant Twisted Pair Foam PE 16.51 .650 16.76 .660 — 50 30.8 55 80 — .178 50 25.0 55 250 1500 Buoyant Antennna 600 psig. Low Loss No Press. Req. PE Tubes PE Foam PE PE Semi-Solid PTFE None 1/Flat BC Braid Waterproofed 10.8 12.7 Corr. Al. .425 .500 — Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 None Foam PE Optional Dimensions are in millimeters over [inches] .097 — — 55 80 — Buoyant Antennna .390 50 26.0 55 80 6000 — .170 50 24.0 55 250 1000 — www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix D - Typical Coaxial Cable Specifications (Continued) Nom. Imped. (Ohms) Nom. Cap pf/ft Max. Operating Temp. (C°) Max. Operating Voltage (Volts RMS) — — — 55 80 — — 50 30.8 55 80 — .336 50 22.8 55 80 2000 Buoyant Antennna 400 lb. Break Watertight See RG14A Low Loss Replaces RG189 10.29 .405 .092 72 — 55 80 5000 Low Noise Cable PVC-IIA w/Armor 12.07 .475 .114 72 — 55 80 5000 Armored RG391 2/SC FEP-IX 9.91 .390 .165 50 29.4 55 200 5000 Moistureproof RG225 6.86 .270 2/SC FEP-IX 8.89 .350 .125 50 28.0 55 200 2000 Low Loss RG393 PTFE 2.95 .116 2/SC FEP-IX 4.95 .195 .050 50 29.3 55 200 1900 — 1.64 SPC .0645 PTFE 5.46 .215 None 6.35 .250 .081 50 29.3 40 125 3000 Semirigid 0.91 SCCS .0360 PTFE 3.02 .119 6.35 OD .250 Copper Tube 3.58 OD .141 Copper Tube None 3.58 .141 .032 50 29.3 40 125 2500 Semirigid PTFE 0.86 .034 2/SC FEP Interlayer FEP-IX 2.95 .116 .0075 50 29.3 55 200 2500 Triaxial RG178B PTFE and Cond. PTFE 0.86 .034 1/SC FEP-IX 1.83 .072 .0054 50 31.5 Max. 55 200 2000 Low Loss RG178B PTFE 1.68 .066 2.18 OD .086 Copper Tube None 2.19 .0865 .015 50 29.4 40 125 1500 Semirigid RG/U Type Cable Inner Conductor Dielectric Material DOD 386 1.29 CCS .0508 PE — 388 CS PE 389 6.35 BC Al. .2500 1.22 .048 7/0.4 TC .0159 1.22 .048 7/0.4 TC .0159 2.38 .0936 7/0.79 SC .0312 2.44 .096 7/0.81 SC .032 0.98 .0385 19/0.2 SPC .0077 401 402 391 392 393 397 400 403 404 405 0.3 SCCS .012 7/0.1 .004 0.3 SCCS .012 7/0.1 .004 0.51 SCCS .0201 Number/Type of Shielding Braids Jacket Material O.D. Weight (lb/ft) Foam PE — None Non-hosing 11.28 .444 Max. SC PE Spline 16.13 .635 2/SC PE-IIIA 16.51 .650 13.84 .545 22.23 .875 Cond. PE and PE 7.24 .285 1/TC PVC-IIA Cond. PE and PE 7.24 .285 1/TC PTFE 7.24 .285 Air-space PTFE Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 PE-IIIA Dimensions are in millimeters over [inches] www.amp.com/communications/com Comments Specifications subject to change. 299 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix E - Maximum Power Handling Capabilities for Cables (Average Input Power in Watts) RG/U Type Cable 5, 5A, 5B 8, 8A, 10A, 213, 215 9, 9A, 9B, 214 11, 11A, 12, 12A, 13, 13A, 216 217 22, 22B 55, 55A, 55B, 223 58, 58B 58A, 58C 59, 59A, 59B 62, 62A, 71, 71A, 71B 62B 115, 115A, 165, 225, 393 108, 108A 122 140, 141, 141A, 142, 142B, 302, 303, 400, 402 143, 143A 144 161, 179, 179A, 179B, 187, 187A 174, 174A 178, 178A, 178B, 196, 196A 180, 180A, 180B, 195, 195A 188, 188A, 316 210 10 2,000 3,700 3,700 2,500 6,000 1,700 800 730 650 1,300 1,300 1,150 25,000 340 540 9,000 11,500 25,000 1,600 170 710 2,500 1,250 8,500 50 800 1,300 1,300 1,000 2,000 650 310 280 225 480 480 420 9,500 145 205 3,500 4,600 9,500 780 72 340 1,100 600 3,300 100 550 850 850 650 1,200 430 205 180 170 310 310 280 6,300 100 140 2,400 3,200 6,300 570 50 240 800 450 2,300 200 350 540 540 400 800 280 137 125 110 200 200 180 4,300 70 90 1,600 2,100 4,300 420 36 170 570 330 1,600 Frequency in MHz 400 230 350 350 260 480 190 90 85 75 135 135 120 2,800 50 60 1,100 1,450 2,800 310 25 123 400 240 1,100 1,000 125 190 190 150 260 110 53 50 44 77 77 69 1,700 30 35 650 850 1,700 200 16 78 250 160 620 3,000 60 95 95 70 120 50 28 25 22 40 40 35 880 15 18 350 460 880 110 — 41 135 80 310 5,000 40 65 65 50 85 38 20 17 15 27 27 25 620 — 12 245 330 620 76 — 28 93 57 220 10,000 22 37 37 26 50 20 10 — — 15 15 14 350 — — 140 190 350 41 — 14 50 30 140 Note: Values above 3 GHz vary considerably depending on construction. Conditions Ambient: 40°C Altitude: Sea level Center Conductor Temperature: 80°C for polyethylene 200°C for PTFE 300 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix F - Nominal Loss Characteristics for Cables (Decibels per Hundred Feet) RG/U Type Cable 5, 5A, 5B 8, 8A, 10A, 213, 215 9, 9A, 9B, 214 11, 11A, 12, 12A, 13, 13A, 216 217 22, 22B 55, 55A, 55B, 223 58, 58B 58A, 58C 59, 59A, 59B 62, 62A, 71, 71A, 71B 62B 115, 115A, 165, 225, 393 108, 108A 122 140, 141, 141A, 142, 142B, 302, 303, 400, 402 143, 143A 144 161, 179, 179A, 179B, 187, 187A 174, 174A 178, 178A, 178B, 196, 196A 180, 180A, 180B, 195, 195A 188, 188A, 316 210 10 .80 .66 .66 .66 .41 1.20 1.35 1.20 1.40 1.10 .90 .90 .60 2.30 1.60 1.20 .85 .38 5.00 3.80 5.30 3.10 3.80 .23 50 1.40 1.50 1.50 1.50 1.00 2.80 3.00 3.10 3.30 2.30 1.90 2.10 1.40 5.20 4.40 2.70 1.80 1.00 7.90 6.50 10.00 4.20 7.90 .58 100 2.90 2.20 2.20 2.20 1.40 4.20 4.30 4.60 4.90 3.30 2.80 3.00 2.10 7.50 6.90 3.90 2.50 1.60 9.80 8.90 13.30 5.10 11.50 .85 200 4.30 3.20 3.20 3.20 2.10 6.30 6.00 7.00 7.30 4.70 3.70 4.30 3.10 11.00 11.00 5.50 3.80 2.30 12.70 12.00 20.00 7.30 15.00 1.30 Frequency in MHz 400 6.40 4.60 4.60 4.60 3.10 9.50 8.80 10.00 11.00 6.70 5.20 6.10 4.50 16.00 16.60 8.00 5.70 3.80 15.80 17.50 27.50 10.40 20.00 1.90 1,000 11.00 9.00 9.00 9.00 5.80 — 16.50 17.50 20.00 11.50 8.50 10.50 7.50 26.20 29.20 13.00 9.70 7.00 25.00 31.00 45.00 16.50 30.00 3.10 3,000 22.00 19.00 19.00 19.00 13.00 — 36.00 38.00 41.00 25.50 18.40 23.50 14.00 54.00 57.20 26.00 18.10 15.10 43.00 64.30 78.00 36.00 58.00 6.50 5,000 30.00 28.00 28.00 28.00 19.00 — 51.00 — — 41.00 29.50 36.00 21.00 — 89.00 36.00 26.10 — 62.50 97.00 115.00 49.50 79.00 9.00 10,000 52.00 47.00 47.00 — 31.00 — 85.00 — — — — — 35.00 — — 62.00 40.70 — 135.00 185.00 172.00 89.00 133.00 15.00 Note: Values above 3 GHz vary considerably depending on construction. Conditions Ambient: 20°C Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 301 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix G - Glossary of Terms A ambient The atmospheric conditions surrounding a given item. Normally in terms of factors which influence or modify, such as temperature, humidity, etc. amplitude The magnitude of variation in a changing quantity from its zero value. The word requires modification - as with adjectives such as peak, maximum, rms, etc. - to designate the specific amplitude in question. arc voltage voltage that continues to pass through a surge protector during activation of GDT(approx. 20 volts ) attenuation A reduction in power. It occurs naturally during wave travel through lines, waveguides, space or a medium such as water. It may be produced intentionally by placing an attenuator in a circuit. The amount of attenuation is generally expressed in decibels per unit of length. B back mounted A connector attached to the inside of a panel or box with its mounting flanges inside the equipment. bayonet coupling A quick coupling device for plug and receptacle connectors. Pins projecting from the outside of the cylindrical receptacle engage with corresponding cam slots in the bayonet plug. bellmouth Flared at the mouth. The rear of a properly crimped wire barrel will have a slight flare (bellmouth) to relieve the strain on the wire strands as they leave the area of high compression and take their natural “lay”. A bellmouth condition may also be present in front of the wire barrel. black box A term used to refer to any assembly or subassembly, usually electronic, that can readily be installed or removed from a larger system. BNC Connector A radio frequency connector covered by Military Specification. It has an impedance of 50 or 75 ohms, and is designed to operate in the 0 to 4 GHz frequency range. It features quick connect/disconnect by pin and cam bayonet coupling. body Main or largest portion of a connector to which other portions are attached. braid A weave of metal fibers used as a shield covering for an insulated conductor or group of insulated conductors. When flattened it may be used as a grounding strap. broad-band E Interference generated over a wide range of frequencies (e.g., automotive ignition noise). bulkhead A term used to define a mounting style of connectors. Bulkhead connectors are designed to be inserted into a panel cutout from the rear (component side) of the panel. C cable Either a standard conductor, with or without insulation and other coverings, or a combination of conductors insulated from each other. cable assembly A completed cable and its associated hardware. capacitance The property of an electrical conductor (dielectric in a capacitor) that permits the storage of energy as a result of electrical displacement. The basic unit of capacitance is the farad, however, measurement is more commonly in microfarads or picofarads. cavity A metallic enclosure in some types of tubes and circuits within which resonant fields may be excited at the microwave frequency to which the cavity is tuned. Usually referred to as resonant cavity. See also: contact cavity. characteristic impedance The ratio of voltage to current at any point along a transmission line on which there are no standing waves. 302 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] circular mil area (CMA) A unit of area equal to the area of a circle whose diameter is 1 mil (0.001 inch). Used chiefly in specifying crosssectional areas of conductors. (See AMP Brochure No. 4402-8, Computing Circular Mil Area for AMP Terminals and Splices). closed entry contact A female contact designed to prevent the entry of a pin or probing device having a cross-sectional dimension (diameter) greater than the mating pin. coaxial cable A transmission line consisting of two conductors concentric with and insulated from each other. In its flexible form it consists of either a solid or stranded center conductor surrounded by a dielectric. A braid is then woven over the dielectric to form an outer conductor. A weatherproof plastic covering, usually vinyl, is placed on top of the braid. connector A coupling device employed to connect conductors to one circuit with those of another circuit. Used to provide rapid connect/disconnect mating with pc boards, posts or another connector. connector assembly Includes housing and contact plus additional components such as hardware used to hold the assembly together and/or make the assembly a functional connector. contact An electrically conductive component designed for use in a multicircuit connector. contact cavity A defined hole in the connector insert or housing into which the contact must fit. See also: cavity. contact durability The number of insertion and withdrawal cycles that a connector must be capable of withstanding while remaining within the performance levels of the applicable specification. contact engaging and separating force Force required to either engage or separate contacts. Values are generally established for maximum and minimum forces. contact inspection hole A hole, perpendicular to the cylindrical rear portion of screw machined contacts, used to check the depth to which wire has been inserted into the barrel. contact resistance Measurement of electrical resistance of mated contacts when assembled in a connector under typical service use. Electrical resistance is determined by measuring from the rear of the electrical area of one contact to the rear of the contact area of the mating contact (excluding both crimps) while carrying a specified test current. contact shoulder The flanged or enlarged portion of a contact that prevents it from being over-inserted into the appropriate contact cavity. The shoulder may also contribute to proper orientation and stability with the connector housing. contact, two-piece A contact made of two separate parts joined by swedging, brazing or other means of fastening to form a single contact. While this provides the mechanical advantages of two metals, it also has the inherent electrical disadvantage of difference in conductivity. corona A discharge of electricity appearing as a bluish-purple glow on the surface of, and adjacent to, a conductor when the voltage gradient exceeds a certain critical value. It is caused by the ionization of surrounding air by high voltage. crimp The final configuration of a terminal barrel after the necessary compression forces have been applied to cause a functional union between the terminal barrel and the wire. crimp height A top to bottom measurement of the crimped barrel, using a crimp height comparator in the prescribed manner. (Refer to AMP Instruction Sheet 7424). crimping dies A term used to identify the shaping tools that, when moved toward each other, produce a certain desirable shape to the barrel of the terminal or contact that has been placed between them. Crimping dies are often referred to as die sets or as die inserts. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix G - Glossary of Terms (Continued) crimping head Tooling containing jaws and linkage for use in pneumatic or hydraulic powered units to crimp loose-piece contacts/terminals that may be too large for hand tool applications. crimping tool A term commonly used to identify a hand held mechanical device that is used to crimp a contact, terminal or splice. crosstalk A magnetic or electrostatic coupling which causes the unwanted transfer of energy from one circuit (disturbing circuit) to another circuit (disturbed circuit) current rating The maximum continuous electrical flow of current recommended for a given situation. It is expressed in amperes. cycle One complete sequence of values of an alternating quantity, including a rise to maximum in one direction and return to zero; a rise to maximum in the opposite direction and return to zero. The number of cycles occurring in one second is called the frequency. D daisy chain A cable assembly with common wires jumpering three or more connections/connectors. The term is also used as a verb, implying to connect in jumper manner. dB Abbreviation — see decibel. D.C. sparkover voltage defined as the maximum voltage across a device before it discharges the energy to ground when subjected to a slowly rising voltage ramp. A rate of rise of 100V/s is usually chosen for testing purposes. decibel A unit expressing the ratio of two voltages, currents or powers. It is equal to 20 times the common logarithm of the ratio of two voltages across or two currents through equal loads, or 10 times the common logarithm of the two powers. One decibel is approximately the smallest change in audible power that can be recognized by the human ear. die closure Term used to designate a crimping area (crimping chamber) when the dies are fully closed or bottomed. Die closure is checked with go/no go plug gage to insure that the crimp produced by the tooling satisfies the crimp height specification. dielectric A material that serves as an insulator. The amount of resistance to voltage in a given insulation. dielectric withstanding voltage The maximum potential gradient that a dielectric material can withstand without failure. discontinuity Rated interconnection: a broken connection (open circuit) or the loss of a specified connection characteristic. Transient phenomena: Short term (temporary) interruption or unacceptable variation in current or voltage. dissipation Unusable or lost energy, such as the production of unused heat in a circuit. distortion An unwanted change or addition to a signal or waveform when it is amplified. This definition excludes noise which is an extraneous signal superimposed on the desired signal. dummy load A dissipative device used at the end of a transmission line or waveguide to convert transmitted energy into heat, so essentially no energy is radiated outward or reflected back to its source. dust cap A device attached to a connector to provide protection against dust and foreign debris. E electromagnetic compatibility (EMC) The ability of an electronic device to operate in its intended environment without its performance being affected by EMI and without generating EMI that will affect other equipment. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] electromagnetic interference (EMI) Unwanted electrical or electromagnetic energy that causes undesirable responses, degrading performance or complete malfunctions in electronic equipment. See also: noise. electromotive force (emf) See voltage. environmentally sealed A unit is provided with gaskets, seals, grommets, potting or other means to keep out moisture, dust, air or dirt which might reduce or impair its performance. F feedthrough A connector or terminal block, usually having double-ended terminals, which permits distribution and bussing of electrical circuits. Also used to describe a bushing in a wall or bulkhead, separating compartments at different pressure levels, with terminations on both sides. ferrule A short tube used to make solderless connections to shielded or coaxial cable. Also molded into the plastic inserts of multiple contact connectors to provide strong, wear-resistant shoulders on which contact retaining springs can bear. flange A projection extending from or around the periphery of a connector and having holes that provide for mounting the connector to a panel or to a mating connector. frequency modulation (fm) A scheme for modulating a carrier frequency in which the amplitude remains constant but the carrier frequency is displaced in frequency proportionally to the amplitude of the modulating signal. An fm broadcast is practically immune to atmospheric and man-made interference. fretting corrosion A form of excellerated oxidation that appears at the interface of contacting materials undergoing slight cyclic relative motion. All non-nobel metals (tin) are susceptible to some degree of fretting corrosion and will suffer contact resistance increases. front mounted A connector is said to be front mounted when it is attached to the outside of the mating side of a panel. A front mounted connector can only be installed or removed from the outside of the equipment. G gas discharge tube (GDT) hermetically sealed device containing an inert gas. GHz See gigahertz. giga A prefix meaning one billion (109). gigahertz (GHz) One billion cycles per second (109 cps). glow mode condition in which the GDT continues to conduct after an impulse passed. Characterized by a visible glow in the device caused by over-heating. ground A connection, intentional or accidental, between an electrical circuit and the earth or some conducting body (e.g. chassis) serving in place of earth. H heat-shrinkable A type of plastic material that has been cross-linked. A term describing tubes, sleeves, caps, boots, films or other forms of plastic which shrink to encapsulate, protect or insulate connections, splices, terminations and other configurations. hermetic Airtight, impervious to external influence, as in a hermetic package. Often used to describe metal-to-metal solder or weld-sealed packages. www.amp.com/communications/com Specifications subject to change. 303 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix G - Glossary of Terms (Continued) hermetic seal Hermetically sealed connectors are usually multiple contact connectors where the contacts are bonded to the connector by glass or other materials and permits maximum leakage rate of gas through the connector of 1.0 micron ft./hr. at one atmosphere pressure for special applications. hertz (Hz) International standard term for cycles per second. Named after the German physicist Heinrich R. Hertz (e.g., 60 cycles per second is equal to 60 hertz or 60 Hz). I impedance (Z) The total opposition offered by a component or circuit to the flow of alternating or varying current. Impedance is expressed in ohms and is similar to the actual resistance in a direct current circuit. In computations, impedance is handled as a complex ratio of voltage to current. impedance match A condition in which the impedance of a component or circuit is equal to the internal impedance of the source, or the surge impedance of a transmission line. This gives maximum transfer of energy from the source to the load, as well as minimum reflection and distortion. impulse discharge current I 1-0 B is defined as the peak current of an 0-9 impulse which the device can withstand ten times (5 of each polarity at 0-5 fixed time intervals) without substan- 0-1 A 0 0 tially affecting device performance. t T 1 T 1 = 1.25T The test normally used to determine T 1 T 2 this capacity uses the 8/20ms waveform as depicted below where T1=8ms and T2=20ms. V impulse sparkover voltage 1.0 8 defined as the maximum level 0.9 of voltage across a device before it discharges the energy to ground when 0.5 A 0.3 subjected to a voltage impulse. The three common waveform profiles used 0 0 t 1 T T =1.67T T 2 to determine this capacity are: T L T 2 inductance One cause of reactance. An electromagnetic phenomenon in which the expanding and collapsing of a magnetic field surrounding a conductor or device tends to impede changes in current. The effects of inductance become greater as frequencies increase. The basic unit for inductance is the henry. input impedance The impedance that exists between the input terminals of an amplifier or transmission line when the source is disconnected. The circuit, signal level and frequency must be specified. insertion loss The loss in load power due to the insertion of a component, connector or device at some point in a transmission system. Generally expressed in decibels as the ratio of the power received at the load before insertion of the apparatus, to the power received at the load after insertion. insulation crimp The area of a terminal splice or contact that has been formed around the insulation of a wire. insulation grip The ability of certain crimped terminals to hold firmly in place both the conductor and a small portion of insulation. This prevents the conductor from being exposed due to insulation receding away from the terminal. insulation resistance The electrical resistance between two conductors separated by an insulating material. interface The two surfaces of a multiple-contact connector that face each other when the connector is assembled. 304 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] interference An electrical or electromagnetic disturbance that causes undesirable response in electronic equipment. J jack A connecting device into which a plug can be inserted to make circuit connections. The jack may also have contacts which open or close to perform switching functions when the plug is inserted or removed. See also: receptacle. L line impedance Impedance as measured across the terminals of a transmission line; frequently the characteristic impedance of the line. M matched impedance The coupling of two circuits in such a way that the impedance of one circuit equals the impedance of the other. mate Two join two connectors in a normal engaging mode. maximum discharge current defined as the peak current of an impulse which the device can withstand once without substantially affecting device performance. mega (M) A prefix meaning one million (106). microwave That portion of the electromagnetic spectrum lying between the far infrared and conventional radio frequency range. The microwave frequency range extends from 1 GHz to 300 GHz. Microwaves are usually used in point-to-point communications because they are easily concentrated into a beam. Military Specification Military requirements. The demand imposed upon a system to meet a military operational need. mismatch The condition in which the impedance of a source does not match or equal the impedance of the connected load. This reduces power transfer by causing reflection. N narrow-band EMI generated from a device operating at a specific and limited range of frequencies. See also: electromagnetic interference (EMI). N Connector A large radio frequency connector covered by Military Specification. It has an impedance of 50 ohms and is designed to operate in the 0 to 11 GHz frequency range. It has a threaded coupling and is physically larger than a TNC connector. noise An extraneous signal in an electrical circuit, capable of interfering with the desired signal. Classes of noise include burst of popcorn noise, intermediate frequency noise at low audio frequencies, white (thermal) noise, etc. Signals from power supply or ground line coupled into an amplifier output may be considered noise. O “O” crimp An insulation support crimp for open barrel terminals and contacts. In its crimped form it resembles an “O” and conforms to the shape of the round wire insulation. “O” crimp is also used to describe the circumferential crimps used on COAXICON ferrules. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix G - Glossary of Terms (Continued) ohm The unit of measurement for electrical resistance. A circuit is said to have a resistance of one ohm when an applied emf of one volt causes a current of one ampere to flow. P panel mount A method of fixing a connector to a board, panel or frame. The mounted connector is usually the receptacle or female connector. The plug or male connector is usually the removable portion. pcb Abbreviation: see printed circuit board. permeability (chemical) The passage or diffusion (or rate of passage) of a gas, vapor, liquid or solid through a barrier without physically or chemically affecting it. permeability (magnetic) The measure of how much better a material is than air as a path for magnetic lines of force. Air is assumed to have a permeability of 1. plug In coaxial RF connectors the plug is usually the movable portion, and is usually attached to a cable or removable assembly. Plugs mate with receptacles, jacks, outlets, etc. printed circuit board An insulating board serving as a base for a printed circuit. When the printing process is completed, the board may include printed components, as well as printed wiring. propagation delay Time required for an electronic digital device, or transmission network to transfer information from its input to its output. propagation delay time The time between the application of a digital input waveform and the corresponding change in input waveform. It is measured between reference points on the waveforms. The time is generally different for positive-going and negative-going waveforms. prototype A model suitable for use in the complete evaluation of form, design and performance. pulse A change in the level, over a relatively short period of time, of a signal whose value is normally constant. pulse width The length of time that the pulse voltage is at the transient level. Electronic pulse widths are usually in the millisecond (10-3), microsecond (10-6) or nanosecond (10-9) range. R receptacle In coaxial RF connectors, the receptacle is usually the fixed or stationary portion that is mounted to the panel. In shell-type, multiplecontact connectors the receptacle usually contains the pin contacts and is mounted on the “cold” side of a circuit such as in a drawer or black box. Receptacles mate with plugs. See also: jack. residual impulse defined as the voltage that will pass through the device prior to activation of the GDT. residual voltage defined as the small amount of voltage left on the line after an impulse passes. resonance A frequency at which captive reactance and inductive reactance are equal and therefore cancel one another’s effects. RF Abbreviation for radio frequency. RG/U Symbol used to designate coaxial cables that are made to Government Specification (e.g., RG-58U; in this designation the “R” means radio frequency, the “G” means Government, the “58” is the number assigned to the government approval, and the “U” means it is a universal specification). rise time The time required for a component or logic circuit to change from the quiescent to the transient state when an input is applied. (i.e. elapsed time between application of input and attainment of full output level). rms Abbreviation for root mean square. root mean square The effective value of an alternating current, corresponding to the direct current value that will produce the same heating effect. S screw machine contact A contact which is machined from solid bar stock. semi-rigid A cable containing a flexible inner core and a relatively inflexible sheathing. sheath The outer covering of a jacket over the insulated conductors to provide mechanical protection for the conductors. Also known as the external conduction surface of a shielded transmission line. shield/shielding (cable) A conducting envelope, composed of metal strands, which enclose a wire, group of wires or cable so constructed that substantially every point on the surface of the underlying insulation is at ground potential or at some predetermined potential with respect to ground. shield/shielding (circuit) The metal sleeving surrounding one or more of the conductors in a wire circuit to prevent interference, interaction or current leakage. Shielding protects a circuit against crosstalk. shock (mechanical) (1) An abrupt impact applied to a stationary object. (2) An abrupt or nonperiodic change in position, characterized by suddenness, and by the development of substantial internal forces. SHV Abbreviation for standard high voltage. sine wave A wave which can be expressed as the sine of a linear function of time, space or both. A waveform, often viewed on an oscilloscope, of a pure alternating current or voltage. skin effect The tendency of alternating currents to flow near the surface of the conductor, thus being restricted to a small part of the total cross-sectional area. This effect increases the resistance and becomes more marked as the frequency rises. sleeve The insulated or metallic covering over the barrel of a terminal. solder contact A contact or terminal having a cup, hollow cylinder, eyelet or hook to accept a wire for a conventional soldered termination. standard high voltage (SHV) A quick connect/disconnect connector series employing a bayonet lock coupling and designated to operate safely up to 5000 volts AC. It is the industry standard connector specified by the National Bureau of Standards (NBS) for high voltage use by the Atomic Energy Commission (AEC). standing-wave Distribution of current and voltage on a transmission line, resulting from two sets of waves traveling in opposite directions. standing wave ratio The ratio between maximum and minimum current or voltage along a line. It is a measure of the mismatch between the load and the line. It is equal to 1 when the line impedance is perfectly matched to the load. (In which case the maximum and minimum are the same, as current and voltage do not vary along the line). The perfect match would be a 1 to 1 ratio. super high frequency (shf) The Federal Communications Commission designation for the band from 3,000 to 30,000 MHz in the radio spectrum. T tensile The amount of axial load (longitudinal stress) required to break or pull the wire from the crimped barrel of the terminal, splice or contact. Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. 305 Catalog 1307191 Revised 10-00 RF Coax Connectors Appendix G - Glossary of Terms (Continued) tensile strength The greatest longitudinal stress that a substance or union can bear without tearing or pulling apart. In crimped terminations, it is the greatest longitudinal stress that a terminal can bear without the wire separating from the terminal. thermal shock The effect of heat or cold applied at such a rate that nonuniform thermal expansion or contraction occurs within a given material or combination materials. The effect can cause inserts and other insulation materials to pull away from metal parts. time-delay A circuit that delays the transmission of an impulse for a definite and desired period of time. TNC Connector A radio frequency connector covered by Military Specification. It has an impedance of 50 ohms and is designed to operate in a 0 to 11 GHz frequency range. Reliability is assured by a threaded coupling that can be safely wired to prevent accidental disconnect. U UG Symbol used to describe coaxial connectors that were made to a Government specification. This specification is now obsolete. ultra-high frequency (uhf) A Federal Communications Commission designation for the band from 300 to 3000 MHz on the radio spectrum. In television - channels 14 to 83 or 470 to 890 MHz. V very high frequency (vhf) A Federal Communications Commission designation for the band from 30 to 300 MHz on the radio spectrum. voice-frequency (vf) Any frequency within that part of the radio frequency range essential to speech transmission of a commercial quality (i.e., 300 to 3400 Hz). Also referred to as telephone frequency. 306 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] volt (V) The unit of measurement for electromotive force (emf). It is equivalent to the force required to produce 1 ampere through a resistance of 1 ohm. voltage (E) The term most often used to designate electrical pressure that exists between two points and is capable of producing a flow of current when a closed circuit is connected between the two points. Voltage is measured in volts, millivolts, microvolts and kilovolts. The terms electromotive force (emf), potential, potential difference and voltage drop are often referred to as voltage. voltage drop The voltage developed across a component or conductor by the flow of current through the resistance or impedance of that component or conductor. voltage hold over refers to the maximum line voltage at which recovery of the GDT to its inactive state will take place within a specified period of time (normally 150ms) after an induced lightning pulse (normally 10/1000ms) has been applied. VSWR Abbreviation for voltage standing wave ratio. Also see: standing wave ratio. W wavelength The distance between two points which are in phase on adjacent waves. It is the distance traveled by the wave in the same span of one cycle. Electromagnetic waves (both light and radio) have a speed in space of about 300,000,000 meters (186,000 miles) per second. Thus wavelength in meters is equal to 300,000,000 divided by frequency. Z Z Letter symbol used to represent impedance in ohms. www.amp.com/communications/com Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Numerical Index Note: This index lists all cataloged parts by base no. only. Complete part nos. (with prefixes and/or suffixes) are shown on the page(s) indicated. Part No. Page 13126 267 13127 267 21027 267 22145 156 43639 248 45638 248 45740 248 50084 249 50095 249 50105 249 50107 249 51563 250, 251 51565 251 51692 18 58124 265 58174 38, 67, 70, 71 58212 244 58248 67, 70, 71 58290 248 58318 20, 27, 267 58376 44 58425 38, 67-71, 84, 92 58433 26, 44-46, 50, 53, 265 58435 26, 44-46, 50, 53 18-21, 26, 37, 58436 44-46, 50, 52, 53, 55, 84, 92 58483 196 58485 18-21 58489 196 58536 38, 67, 69-71 58537 46, 50, 51, 53 58538 38, 46, 67 58539 28, 29, 31, 44, 46 58558 45, 46, 67 58559 67 58621 92 20, 27, 32, 158, 59980 266, 267 59981 156, 267 59993 244 69140 45, 50, 53, 265 69141 46, 50 69186 248 69220 248 69222 248 69223 45, 50, 53 69224 50 69227 248 69245 31, 44, 50, 52 69248 248 69315 248 69331 45 69365 18, 20, 244, 265 69373 248 69408 44, 52 69422 44, 50 69424 44, 50 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 69429 69471 69477 69477 69478 69652 69656 69667 69669 69672 69675 69690 69708 69710 69727 148385 148386 200009 201097 201098 201142 201143 201144 201145 201146 201511 201512 220000 220009 220015 220026 220043 220045 220061 220062 220088 220152 220152 220187 220187 220189 220210 220211 220217 220220 220221 220222 220224 220241 220247 221014 221108 221123 221128 221158 221162 221185 221198 221199 Page 45 44, 52 44, 46, 50-53 265 45, 50, 51, 53 46 250, 251 88 44, 46, 50-53 248 248 250, 251 88 18, 20, 244, 265 45, 50, 51, 53 239 239 44 248 248 248 248 248 248 248 248 248 46 44, 50-52 18-20, 26, 28, 46, 265 44, 48, 50-52 46 18-20, 26, 28, 29, 31, 33 156 18, 20 46 44-46 67 44-46, 50 26, 53, 55 28, 29, 31, 45, 48, 50, 51, 53, 55 97 266 44-46, 50, 52, 53, 55 20, 32, 267 20, 32, 267 267 267 20 46 188 58, 59, 73, 74 61 44-46, 55 245 245 67 89 70 Dimensions are in millimeters over [inches] Part No. 221221 221244 221325 221336 221402 221461 221486 221500 221506 221509 221539 221540 221543 221551 221586 221629 221789 221790 221848 221951 221980 221981 221988 222006 222015 222016 222092 222117 222132 222163 222165 222196 222197 222200 222420 222428 222462 222506 222728 222785 225014 225088 225092 225093 225345 225348 225349 225361 225363 225395 225396 225397 225398 225550 225551 225554 225555 225557 225559 225661 225662 Page 71 72 36 76 69 188 188 36 38 38 92 92 64 65 64 66 120 121 248 56, 72 244 244 64 62, 75 245 245 73 77 74 62, 75 65 156 156 156 61 51 62, 75 26 47 58 19 251 18 19 26 33 28 18, 20 20 44-46 50 51 52, 53 26 29 28 26 31 28 18 18 Part No. 225663 225667 225669 225886 225973 225974 226023 226060 226537 226978 226987 226990 226993 227000 227079 227086 227161 227169 227222 227223 227426 227433 227661 227670 227671 227672 227673 227676 227677 227699 227715 227716 227726 227754 227755 227758 227760 227762 227764 227812 227816 227818 227820 227835 227838 227839 227945 228179 228215 228216 228226 228448 228502 228507 228553 228596 228616 228618 228658 228686 228863 www.amp.com/communications/com Page 19 20 19 46 48 48 250 250 251 60 60 58 59 26 44-46 18 58 56 59 56, 72 57 58 58 59 59 59 59 58 58 61 56 56 57 56 56 35 35 35 35 34 34 34 34 34 34 34 22 27 183 183 65 20 32 32 180 244 244 244 20 89 267 Specifications subject to change. 307 Catalog 1307191 Revised 10-00 RF Coax Connectors Numerical Index (Continued) Part No. 228979 228980 258436 258537 269140 269223 269245 269331 269422 269429 269477 269478 269669 269727 282933 282938 305183 307581 308075 311386 311392 311395 311396 312067 312253 312317 312644 312645 313719 313720 313745 313746 314590 314700 318450 318451 318452 328663 328664 328666 328667 329006 329444 329445 329446 329452 329456 329458 329517 329518 329545 329549 329631 329632 330022 330024 330061 330062 330063 330478 308 Page 50 52, 53 48 48 48 48 48 48 48 48 48 48 48 48 96 96 248 267 20 267 267 158, 267 267 267 20, 27, 32, 156, 158, 267 158, 267 27 27 20 20, 27 156 156 265 265 28, 29, 31, 44 38, 67, 70, 71 44 248 248 248 248 248 45 46 44 50 53 52 65 64 50 50 58-60, 74, 89 58-60, 74, 89 66 65 44 50 52 248 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 330620 330878 331175 331178 331182 331238 331350 331351 331693 331974 332004 332056 332057 332215 332225 332342 341281 354500 354940 413012 413020 413024 413025 413194 413242 413249 413364 413366 413453 413476 413506 413515 413524 413528 413557 413558 413588 413589 413590 413591 413592 413631 413760 413771 413779 413879 413933 413959 413969 413985 413986 413990 413996 414002 414026 414048 414075 414075 414088 414094 414105 Page 54, 74 46 48 48 48 31 44-46 50 52 52 156 250, 251 250, 251 90 88 88 265 266 18, 20, 38, 46 157 157 157 157 73 158 158 66 64 66 82 39 82 82 74 66 76 69 67, 68 68, 71 38 64 63 70 52, 53 50 58 35 48 61 179 75 181 182 179 182 187 187 187 75 82 65 Dimensions are in millimeters over [inches] Part No. 414138 414168 414170 414171 414173 414194 414215 414217 414244 414265 414284 414287 414305 414311 414337 414352 414363 414367 414373 414379 414394 414396 414409 414410 414414 414449 414459 414460 414493 414553 414612 414614 414618 414651 414666 414724 414758 414766 414767 414852 414858 414864 414907 414910 414915 414918 414933 414946 414948 414963 414969 414983 414985 415000 415006 415010 415020 415024 415025 415046 415057 Page 82 31 180 29 28 57 82 72 188 47 82 90 61 64 182 82 179 85 63 182 75 39 73 73 65 35 73 61 84 84 181 84 187 83 65 46, 67 84 92 187 44-46 67 58 73 39 44-46 67 74 179 180 182 185 74 179 37 180 83 77 95 63 58 82 Part No. 415085 415087 415103 415187 415188 415189 415205 415214 415216 415218 415226 415232 415242 415248 415252 415255 415276 415302 415327 415332 415340 415366 415367 415368 415369 415372 415373 415377 415380 415381 415382 415406 415407 415417 415419 415436 415462 415476 415484 415487 415490 415500 415504 415520 415523 415569 415577 415590 415632 415633 415634 415655 415672 415683 415710 415711 415712 415715 415773 415774 415832 www.amp.com/communications/com Page 83 55 82 72 37 61 83 95 83 58 92 18 19 20 21 19 95 94 98 97 182 244 244 244 244 63 77 186 182 182 182 98 55 73 73 93 187 94 185 185 186 185 186 74 98 93 188 181 74 73 73 73 182 97 93 93 93 60 181 181 90 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Numerical Index (Continued) Part No. 415888 447314 447315 447648 448089 448103 603995 679304 764593 813599 852113 852114 887000 887046 887058 887078 887089 887098 904800 904804 904805 1044764 1044851 1049678 1050525 1050542 1050548 1050591 1050598 1050602 1050611 1050718 1050740 1050742 1050757 1050770 1050854 1050859 1050900 1050903 1050909 1050911 1050996 1051005 1051007 1051046 1051052 1051081 1051085 1051136 1051140 1051145 1051147 1051151 1051157 1051638 1051644 1051852 1051855 1051861 1051862 Page 97 156 156 110 156 110 266 18, 20 265 266 158 158 97 96 98 94 96 92 239 239 239 217 163 167 103 103 103 105 105 105 105 108 105 105 103 103 103 103 108 108 106 106 109 106 106 104 104 104 104 109 109 106 106 105 105 107 107 107 110 107 110 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 1051867 1051869 1051942 1052063 1052067 1052072 1052076 1052093 1052098 1052324 1052339 1052343 1052349 1052356 1052360 1052422 1052518 1052522 1052523 1052528 1052534 1052544 1052548 1052552 1052561 1052563 1052577 1052622 1052625 1052628 1052634 1052643 1052646 1052649 1052652 1052684 1052689 1052898 1052902 1052978 1052982 1052986 1053073 1053092 1053134 1053222 1053354 1053378 1053488 1053635 1053646 1053788 1054426 1054869 1055018 1055047 1055065 1055420 1055439 1055440 1055441 Page 110 110 107 108 108 111 111 111 111 112 114 112 115 117 117 112 115 115 115 118 113 113 115 115 117 117 118 119 119 119 119 119 120 119 120 119 119 117 118 116 116 116 113 114 114 116 120 121 121 121 260 263 123 123 122 122 122 124 40, 124 40, 124 40, 124 Dimensions are in millimeters over [inches] Part No. 1055442 1055443 1055444 1055445 1055446 1055447 1055448 1055449 1055450 1055451 1055454 1055469 1055474 1055475 1055476 1055477 1055500 1055689 1055690 1055692 1055694 1055695 1055696 1055697 1055831 1055832 1055833 1055834 1055835 1055836 1055837 1055838 1055839 1055840 1055841 1055842 1055843 1055886 1056436 1056438 1056441 1056443 1056445 1056447 1056450 1056452 1056456 1056458 1056460 1056462 1056526 1056527 1056553 1056554 1056702 1056706 1056707 1056708 1056721 1056722 1056724 Page 124 124 124 124 124 124 124 124 124 124 124 40 40 40 40 40 124 217, 225 225, 230 225 221, 231, 259 221, 231, 257 221, 231, 263 221, 231, 264 124 124 124 124 124 124 124 124 124 124 124 124 124 225, 230 109 109 109 109 110 110 110 110 111 111 111 111 152 152 152 152 259 257 263 264 153 153 153 Part No. 1056726 1056728 1056729 1056731 1056734 1056736 1056743 1056744 1056745 1056749 1056750 1056751 1056752 1057088 1057094 1057116 1057119 1057165 1057176 1057275 1057277 1057279 1057284 1057286 1057290 1057341 1057343 1057367 1057374 1057377 1057381 1057383 1057385 1057387 1057388 1057390 1057392 1057463 1057631 1057635 1057651 1057676 1057679 1057697 1057699 1057775 1057777 1057780 1057839 1057841 1057843 1057845 1057849 1057851 1057853 1057855 1057857 1057858 1057860 1057908 1058056 www.amp.com/communications/com Page 153 154 153 153 153 153 153 153 153 153 154 154 154 18 18 19 19 20 20 21 21 21 21 21 21 258 258 257 22 263, 264 261 263 261 262 261 261 261 258 27 27 30 32 32 33 33 36 36 36 258 259 258 258 257 257 263 262 262 262 262 259 258 Specifications subject to change. 309 Catalog 1307191 Revised 10-00 RF Coax Connectors Numerical Index (Continued) Part No. 1058058 1058066 1058067 1058077 1058079 1058081 1058083 1058117 1058651 1058653 1058664 1058666 1058667 1058675 1059399 1059402 1059408 1059409 1059410 1059412 1059413 1059451 1059452 1059456 1059465 1059467 1059505 1059521 1059523 1059525 1059540 1059541 1059550 1059551 1059572 1059594 1059596 1059610 1059632 1059637 1059654 1059657 1059665 1059671 1059681 1059684 1059691 1059707 1059711 1059716 1059718 1059720 1059724 1059726 1059729 1059731 1059733 1059756 1059758 1059774 1059829 310 Page 258 257 257 262 262 263 262 258 259 259 261 264 261 259 164 162 164 164 162 162 260 164 164 162 163 163 163 165 165 165 165 165 166 166 171 167 167 168 170 170 168 168 170 171 169 169 169 259 257 264 261 261 260 257 259 259 259 264 261 163, 166 152 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 1059868 1059884 1059888 1059894 1059902 1059903 1059905 1060487 1060494 1060498 1060500 1060772 1060774 1060787 1060788 1060811 1060813 1060815 1060817 1060868 1060869 1060871 1060872 1060875 1060881 1060882 1060883 1060884 1060959 1060960 1060984 1060985 1060989 1060995 1060996 1061002 1061007 1061015 1061022 1061023 1061026 1061027 1061029 1061030 1061035 1061070 1061071 1061072 1061073 1061092 1061094 1061738 1061739 1061742 1061744 1061750 1061751 1061752 1061753 1061757 1061758 Page 174 175 175 176 176 175 176 259 257 263 263 200 201 201 199 200 200 200 200 199 199 199 199 199 200 200 200 200 202 202 201 201 201 201 201 203 202 201 202 202 202 202 202 202 203 258 257 263 260 203 203 260 260 260 260 263 260 261 262 260 262 Dimensions are in millimeters over [inches] Part No. 1064303 1064309 1064315 1064331 1064333 1064338 1064353 1064357 1064358 1064367 1064369 1064374 1064375 1064391 1064393 1064397 1064399 1064401 1064409 1064411 1064414 1064416 1064530 1064533 1064535 1064538 1064540 1064542 1064543 1064544 1064545 1064546 1064547 1064548 1064549 1064550 1064552 1064553 1064554 1064555 1064556 1064557 1064558 1064559 1064560 1064561 1064562 1064563 1064564 1064565 1064566 1064567 1064568 1069249 1080291 1081124 1081242 1082029 1082030 1082034 1082845 Page 226 226 226 230 230 230 226 226 226 227 227 228 228 227, 230 227 227 228 228 227 227 227 228 217 217 218 218 218 218 219 219 219 220 220 220, 221 220 221 219 219 219, 221 220 220 220 220 221 219 219 219 220 220 220 220 221 221 12 30 227 168 104 105 109 218 Part No. 1082846 1082847 1083946 1085221 1085456 1086008 1086009 1088312 1088313 1091559 1091921 1221286 1221879 1222092 1223104 1251802 1253777 1254242 1255378 1255379 1255511 1274007 1274020 1274026 1274027 1274028 1274032 1274035 1274045 1274062 1274064 1274084 1274086 1274096 1274113 1274124 1274127 1274191 1274192 1274193 1274194 1274220 1274221 1274291 1274314 1274315 1274323 1274359 1274360 1274401 1274423 1274425 1310432 1310520 1310521 1310690 1310692 1310693 1310697 1310700 1310702 www.amp.com/communications/com Page 218 218 217, 225 201 209 209 209 105 209 121 103 221, 225, 230 162 162 120 217, 225, 230 200 225 211 213 174 78 96 84 84 77 97 180 98 83 97 73 72 120 156 76 76 240 240 240 240 241 241 75 62 62 96 75 61 97 96 77 210 213 213 47 47 55 47 47 47 Specifications subject to change. Catalog 1307191 Revised 10-00 RF Coax Connectors Numerical Index (Continued) Part No. 1310705 1310707 1310712 1310727 1310775 1310776 1310777 1310778 1310791 1310792 1310793 1310970 1311097 1311098 1311099 1311100 1311101 1311102 1311103 1311104 1311106 1311108 1311111 1311114 1311115 1311117 1311118 1311120 1311121 1311122 1311125 1311126 1311127 1311164 1311205 1311206 1311208 1311209 1311213 1311218 1311221 1311225 1311318 1311378 1311379 1311555 1311671 1311674 Page 47 49 49 65 47 47 47 49 51 54 54 51 190 190 190 190 190 190 191 191 191 191 191 192 192 193 193 192 192 192 194 194 195 195 261 258 262 258 190 3 4 5 22 27 27 8 55 47 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Part No. 1311685 1311690 1311691 1311696 1311698 1311699 1311700 1311701 1311702 1312078 1312079 1312105 1312112 1312113 1312121 1312122 1312123 1312124 1312137 1312138 1312139 1312370 1312559 1312569 1313265 1313275 1313291 1313334 1313364 1313453 1313507 1313508 1313511 1313512 1313883 1313887 1314101 1314102 1314103 1314422 1314660 1314669 1314675 1314694 1314874 1314875 1314882 1327037 Page 47 51 54 190 191 193 193 192 195 262 11 65 190 3 12 15 16 16 15 12 16 192 47 30 213 211 49 213 195 257 190 191 192 193 193 193 54 194 194 193 8 190 191 192 47 47 47 51 Dimensions are in millimeters over [inches] Part No. 1327083 1328162 1328427 1328461 1328481 1328580 1328873 1329173 1329174 1329175 1329187 1329293 1329818 1329819 1329846 1330126 1330400 1330401 1330723 1331026 1331180 1331705 1331959 1361137 1361138 1361139 1361169 1361579 1362390 1362489 1362765 1362990 1362991 1362992 1363106 1363301 1363524 1363525 1363526 1363527 1363670 1392011 1392019 1392020 1392028 1393488 1393494 1393524 Page 193 191 49 27 49 32 4 210 210 210 210 199 14 15 167 201 212 212 199 5 32 196 3 14 15 16 204 190 8 27 3 204 204 205 205 199 6 6 6 6 128 234, 235 242 242 235 147 147 146, 147 Part No. 1393562 1393575 1393662 1393665 1393668 1393670 1393672 1393677 1393679 1393680 1393681 1393682 1393696 1393757 1402314 1408002 1408003 1408004 1408005 1408006 1408026 1408027 1408028 1408029 1408030 1408031 1408032 1408033 1408034 1408035 1408036 1408037 1408038 1408039 1408040 1408041 1408049 1408050 1408051 1408052 1408053 1408062 1408074 1408075 1421020 www.amp.com/communications/com Page 130, 141 135 243 143-145, 257, 260, 264 242 127-129, 142, 257, 260, 264 134-136 234 140 133, 135-137 133, 134, 136, 138-140, 145 133-137 254 135, 138, 234, 235 12 228 228 229 229 229 4 4 3 3 3 3 5 5 5 5 6 7 4 8 8 191 211 211 212 212 190 7 213 213 7 Specifications subject to change. 311 Catalog 1307191 Revised 10-00 RF Coax Connectors Engineering Notes 312 Technical Support Center/AMP FAX Service 1-800-522-6752 717-986-7777 Dimensions are in millimeters over [inches] www.amp.com/communications/com Specifications subject to change. Contact Us Worldwide Catalog 1307191 Revised 10-00 Americas Argentina – Buenos Aires Chile – Santiago United States – Harrisburg, PA Phone: + 54-1-733-2000 Fax: + 54-1-717-0988 Phone: + 56-2-739-1230 Fax: + 56-2-739-1227 Phone: + 1-717-564-0100 Fax: + 1-717-986-7575 Brazil – Sao Paulo Colombia – Bogota Venezuela – Caracas Phone: + 55-11-861-1311 Fax: + 55-11-861-0397 Phone: + 57-1-231-9398 Fax: + 57-1-240-3769 Phone: + 58-2-986-7774 Fax: + 58-2-986-9739 Canada – Toronto Mexico – Mexico City Phone: + 1-905-475-6222 Fax: + 1-905-474-5520 Phone: + 52-5-729-0400 Fax: + 52-5-361-8545 For Latin/South American Countries not shown Phone: +54-11-4733-2015 Fax: +54-11-4733-2083 Asia/Pacific Australia – Sydney Malaysia – Selangor Phone: + 61-2-9840-8200 Fax: + 61-2-9899-5649 Phone: + 60-3-7053055 Fax: + 60-3-7053066 India – Bangalore New Zealand – Auckland Phone: + 64-9-634-4580 Fax: 64-9-634-4586 Singapore – Singapore Phone: + 91-80-841-0200 Fax: + 91-80-841-0210 Indonesia – Jakarta People’s Republic of China Phone: + 6221-526-7852 Fax: + 6221-526-7856 Hong Kong Phone: + 852-2735-1628 Fax: + 852-2735-0243 Shanghai Phone: + 86-21-6485-0602 Fax: + 86-21-6485-0728 Shunde Phone: + 86-765-7751368 Fax: + 86-765-7752823 Taiwan – Taipei Phone: + 886-2-2325-0391 Fax: + 886-2-2325-0398 Japan – Tokyo Phone: + 81-44-844-8111 Fax: + 81-44-812-3207 Korea – Seoul Phone: + 82-2-3274-0535 Fax: + 82-2-3274-0524/0531 Philippines – Makati City Phone: + 632-867-8641 Fax: + 632-867-8661 Phone: + 65-482-0311 Fax: + 65-482-1012 Thailand – Bangkok Phone: + 66-2-955-0500 Fax: + 66-2-955-0505 Vietnam – Ho Chi Minh City Phone: + 84-8-8232-546/7 Fax: + 84-8-8221-443 Europe/Middle East/Africa Austria – Vienna Germany – Bensheim Norway – Nesbru Sweden – Upplands Vasby Inside: Phone: + 49-6251-133-0 Fax: + 49-6251-133-600 Phone: + 47-66-77-8899 Fax: + 47-66-77-8855 Phone: + 46-8-50-72-50-00 Fax: + 46-8-50-72-50-01 Germany – Neunkirchen - HTS Div. Poland – Warsaw Phone: + 48-22-611-59-30 Fax: + 48-22-672-47-88 Switzerland – Steinach Portugal – Lisbon Phone: + 351-1-387-70-16 Fax: + 351-1-387-71-72 Turkey – Istanbul Phone: + 44-208-954-2356 Fax: + 44-208-954-6234 Greece – Athens Romania – Bucharest Ukraine – Kiev Phone: + 40-1-311-3479/3596 Fax: + 40-1-312-0574 Phone: + 38-044-246-5501 Fax: + 38-044-246-5501 Phone: + 0222-277-97-0 Fax: + 0222-277-97-333 Outside: Phone: + 43-1-277-97-0 Fax: + 43-1-277-97-333 Belgium – Kessel - Lo Phone: + 32-16-35-23-00 Fax: + 32-16-35-23-52 Bulgaria – Sofia Phone: + 359-2-971-2152 Fax: + 359-2-971-2153 Czech Republic – Kurim Phone: + 420-5-41-162-111 Fax: + 420-5-41-162-223 Denmark – Viby Phone: + 45-86-295-055 Fax: + 45-86-295-133 Egypt – Cairo Phone: + 202-417-76-47 Fax: + 202-419-23-34 Estonia – Haabneeme Phone: + 372-6205-900 Fax: + 372-6205-980 Finland – Helsinki Phone: + 358-9-512-34210 Fax: + 358-9-512-34250 France – Cergy - Pontoise Phone: + 33-1-3420-8888 Fax: + 33-1-3420-8600 1307191-10M-LUG-NVO-10-00 Printed in U.S.A. http://www.amp.com/communications/com Phone: + 49-2247-305-0 Fax: + 49-2247-305-122 Great Britain – London Phone: + 30-1-9370-396/7 Fax: + 30-1-9370-655 Holland – ’s-Hertogenbosch Phone: + 31-73-624-62-46 Fax: + 31-73-621-23-65 Hungary – Budapest Phone: + 36-1-350-8633 Fax: + 36-1-350-8634 Phone: + 7-095-926-5506/07/08/09 Fax: + 7-095-926-5505 Russia - St. Petersburg Phone: + 7-812-325-30-83 Fax: + 7-812-325-32-88 Slovakia – Banska Bystrica Israel – Tel Aviv Phone: + 972-3-649-1482 Fax: + 972-3-648-4041 Slovenia – Ljubljana Italy – Torino South Africa – Midrand Phone: + 27-11-314-10-89 Fax: + 27-11-314-19-10 Lithuania – Vilnius Phone: + 370-2-231-402 Fax: + 370-2-231-403 Phone: + 90-212-281-8181/2/3 Fax: + 90-212-281-8184 Russia - Moscow Ireland – Dublin Phone: + 353-1-820-3000 Fax: + 353-1-820-9790 Phone: + 39-011-4012-111 Fax: + 39-011-4031-116 Phone: + 41-71-447-0447 Fax: + 41-71-447-0444 Phone: + 421-88-415-20-11/12 Fax: + 421-88-415-20-13 Phone: + 386-61-161-3270 Fax: + 386-61-161-3240 Spain – Barcelona Phone: + 34-93-291-0330 Fax: + 34-93-201-7879 Tyco Electronics Corporation, Harrisburg, PA 17105 Technical Support Center Phone: 1-800-522-6752, fax: 717-986-3316; Internet; For Middle East/African Countries not shown Phone: +33-1-34-20-83-83 Fax: +33-1-34-20-86-09