Preview only show first 10 pages with watermark. For full document please download

The Pdf Configuration Worksheet Here

   EMBED


Share

Transcript

BERTHOLD ELECTRIC CO. / GENERATOR CONNECTION CABINET / CALL US TOLL-FREE at 800.657.6650 CONFIGURATION WORKSHEET: To order a Berthold Generator Connection Cabinet, please use the charts below. To begin, select from each section in Column A at right to create your Catalog Number. Example: The catalog number for a wall-mount, 400A, 480/277V. 3-phase 4-wire Generator Connection Cabinet with mechanical lugs for the permanent connections and male Cam-Loks for the temporary connections is W04-5S-M. A MOUNTING STYLE W ................ Wall Mount P ................... Pad Mount RATED CONTINUOUS CURRENT 04 ................ 400 AMPERES 08 ................ 800 AMPERES 12 ............... 1200 AMPERES 16 ............... 1600 AMPERES 20 .............. 2000 AMPERES 24 ............... 2400 AMPERES 28 ............... 2800 AMPERES 32 ............... 3200 AMPERES 40 ............... 4000 AMPERES SYSTEM VOLTAGE * NEMA two hole punching only Compression lugs supplied by others ** Generator Connections Cam-Loks - Quantity provided based on 400A per connector 1 ........... 120/240V 1PH. 3W 2 .......... 120/240V 3PH. 4W 3 .......... 208/120V 3PH. 4W 4 ................. 480V 3PH. 3W 5 .......... 480/277V 3PH. 4W 6 .......... 600/347V 3PH. 4W (NOTE: 6 IS NOT UL LISTED) PERMANENT BUS CONNECTIONS S ... Mechanical Set Screw Lugs C ... Long Barrel Compression Lugs (available for copper cables only) Next, select all options that apply from Column B to customize your Generator Cabinet. If no additional options required, leave this field blank. B OPTIONS 1 ... Access panel interlocking micro switch 2 ...... Key Interlock Provision (for user-provided Kirk Key interlock) 3 ...... Phase Sequence Indication 4 ...... Security Cabinet 5 ...... Convenience Outlet Provision 6 ...... Cam-Lok Snap Covers 8 ..... Welded Construction 9 ....... Powder Coat Finish 10 ..... Stainless Steel Construction 13 ..... 20A terminal strip for auto-start and control wiring (Not UL Listed) S ... Mechanical Set Screw Lugs First Name: Last Name: Company: Company Type: Phone: Email: Please include any other information that will assist us: NOTE: Options 4 and 6 are not available if you have chosen (S) Mechanical Set Screw Lugs for the Generator Connections. C CONFIGURATION CATALOG NUMBER P .. *NEMA two hole punching only **GENERATOR CONNECTIONS M ... Male E1016 Series Cam-Loks F ... Female E1016 Series Cam-Lok CONTACT INFORMATION: Enter your catalog number from Column A here. Enter any selections from Column B here. EX: 1, 5, 8 Request a quote online: http://genconcab.com/request-a-quote/ SUBMIT YOUR WORKSHEET SCAN & EMAIL: [email protected] MAIL: Berthold Electric Co. 1900 West Carroll Avenue Chicago, Illinois 60612 FAX: 312.243.5811