Preview only show first 10 pages with watermark. For full document please download

The Pm172 Series Advanced Power Analyzers Offer The Best Price

   EMBED


Share

Transcript

Enhanced PM172-N Series Advanced FEEDER Monitor Power “P” Model The SATEC Model PM172-N Series advanced monitors offer the best price/performance ratio for any advanced power instrumentation in the market today. PM172’s extensive features make it ideal for applications such as revenue billing and utility SCADA. It is also ideal for substation automation because of its support for the industry standard DNP3.0 and Modbus RTU protocols. The PM172-N fits both the ANSI C39.1 4-inch round cutout for analog meter replacement as well as the DIN 96x96mm² cutout. Its galvanically isolated voltage, current, and power supply inputs make it extremely durable and reliable even in the harshest substation environment. Integrated / Remote Display Module ƒ Display module can be integrated with the base unit or mounted remotely ƒ 3 line high-visibility 7-segment LED display, fully visible under bright sunlight ƒ Two 4-digit and one 6-digit window ƒ Simultaneous display of 3 phase parameters for quick phase balance assessment ƒ 6-digit Energy readings (E model) ƒ Configurable 8-segment LED % Load Bar mimics analog meter needle ƒ Energy pulse LED (E Model) ƒ Communications activity LEDs ƒ Kilo and Mega LEDs for automatic scaling indicators ƒ Menu driven selection and password protected device configuration ƒ Automatic scrolling with adjustable scroll time or fixed display ƒ User configurable, simple two-button Demand RESET operation ƒ Adjustable update time from 0.1 to 10 seconds ƒ Supports a second remote display module over RS485 Wiring configurations ƒ Each model accepts all wiring configurations, selectable from the front panel ƒ Supports Wye and Delta in 2-element, 2½-element, and 3-element wiring configurations ƒ ƒ ƒ ƒ Digital Inputs 2 Dry Contact Digital Inputs Status or breaker monitoring Time stamp operation to 1ms (E model) Pulse counting and accumulation with user configurable weighting factors SATEC INC: PM172 Rev. March 2007 Demands ƒ Configurable demand calculation to match utility settings ƒ Demand period from 1 to 60 minutes. ƒ Number of demand periods from 1 to 15 ƒ External synchronization for demand interval with Status Input or via communications Basic Power Quality Measurements ƒ %THD Volts per phase ƒ % THD Amps per phase ƒ %TDD Amps per phase Real-time Clock ƒ 30 ppm real-time clock ƒ Supports GPS Synchronization via digital input & communication Choice of models ƒ P Model for real-time power measurements ƒ E Model for Energy and Demand measurements with memory STANDARD FEATURES Measurements ƒ Class 0.2S revenue accuracy ƒ 128 samples per cycle true RMS measurements ƒ Fast, real-time, cycle by cycle measurements, averaging values of 8, 16, or 32 cycles, selectable via front panel ƒ Four-Quadrant measurements ƒ Min/Max values (instantaneous & demands) Logical Set Point Configuration RDM172E Remote Display Module Relay Outputs ƒ 2 programmable Form A relays ƒ Energy pulsing output (Wh, VARh, VAh) (E model) ƒ Alarming via programmable set point triggers such as phase loss, low volts demands, etc ƒ Manual control via communication commands ƒ Fail Safe mode Setpoints ƒ 16 user programmable setpoints with actions ƒ Independent Operate & Release Limits ƒ Independent Operate & Release Time Delays ƒ Logical AND/OR conditions ƒ Fast 50 ms update ƒ Choice of actions: ƒ Close / Open relay ƒ Increment / Clear counters Communications ƒ Two independent communications ports ƒ COM1 - optically isolated RS232/422/485 port, selectable via front panel ƒ Supports industry standard Modbus RTU, ASCII, DNP3.0, Modbus/TCP, DNP3/TCP protocols ƒ Optional 10/100 BaseT Ethernet ƒ Optional 56K modem ƒ Optional Profibus DP ƒ COM2 - optically isolated RS422/485 port ƒ Supports industry standard Modbus RTU, ASCII and DNP3.0 protocols ƒ Unique “Assignable Register Map” allows users to assign registers from different ranges into a single contiguous Modbus address space or a DNP Class 0, 1, 2, or 3 poll, limiting the amount of data passed over the communications line and therefore making efficient use of the available bandwidth ƒ Supports up to 2 AX8 Analog Expanders for an additional 16 analog output channels ƒ Firmware upgradeable via communications, eliminating chip replacement Enhanced PM172-N Series Advanced FEEDER Monitor ƒ Supports wrap-around and Stop-on-Full recording modes Assignable Register Map Data Log Setup Time-Of-Use (TOU) ƒ Configurable to match any utility billing profile ƒ 8 Energy and Maximum Demand Registers ƒ 8 tariffs for each energy register Energy “E” Model Internal Memory (E Model) ƒ 1MB of non-volatile memory ƒ User-partition for Event Log and Data Logs. ƒ Up to 140 days of trending & load profile (16 measurements @ 15 minute interval) TOU Calendar with Daily Profiles Software and Integration System Integration ƒ Easy integration with Energy Management or SCADA systems via Modbus RTU, ASCII, DNP3.0 protocols ƒ Remote display and logging of all measured parameters ƒ Automatic/Remote Alarm & Control ƒ Remote configuration PAS Software ƒ Included with every SATEC device ƒ Easy to use remote configuration software ƒ Supports off-line programming to allow easy downloading of a standard configuration to multiple meters ƒ Supports scheduled polling, viewing of real-time data, and automatic retrieval of historical data ƒ Provides the ability to export waveform and data logs to COMTRADE and PQDIF formats ƒ Advanced Power Quality Analysis Installation & Connections ƒ Each model accepts all wiring configurations, selectable via the front panel ƒ Analog meter replacement. Mounting standard to both ANSI C39.1 4-inch round and DIN 96x96 mm² cutouts ƒ Direct connection up to 400/690V or via PT ƒ Configurable PT and CT ratios via front panel ƒ Optional switchboard case for retrofit situations Contact factory for details TOU Registers Log Profile / Data Trend Event Log ƒ 1 Event Log of programmable depth ƒ Supports wrap-around and stop-on-full recording modes Data Logs ƒ 16 Data Logs of 16 parameters each ƒ Configurable depth ƒ Recording intervals from 1 to 9999 seconds SATEC INC: PM172 Rev. March 2007 Optional Inputs/Outputs Analog Outputs (optional) ƒ 2 isolated, programmable Analog Outputs ƒ Fast 1-cycle update time ƒ Settable to any electrical measurement ƒ Programmable HI/LO Ranges Analog Inputs (optional) ƒ 2 isolated, programmable Analog Inputs ƒ Fast 1-cycle scan time ƒ For monitoring substation and transformer temperature, oil level and pressure, etc. Warranty: 3 Year limited warranty Environmental Conditions Operating Temp.: -4 to 140°F (-20 to +60°C) Storage Temp.: -13 to 176°F (-25 to +80°C) Humidity: 0 to 95% non-condensing Enhanced PM172-N Series Advanced FEEDER Monitor Accuracy Voltage: 0.2% reading + 0.01% F.S. (10% to 120% Nominal) Range: 0 to 1,150,000V Starting Voltage: 1.5% F.S. Current: 0.2% reading + 0.02% F.S. (1% to 200% Nominal) Range: 0 to 10,000A Starting Current: 0.1% F.S. I Neutral: 0.6% F.S. (2% to 150% Nominal) Frequency: 0.02% reading (15 to 480 Hz) PF: 0.2% F.S. (|PF| ≥ 0.5) THD: 1.5% reading + 0.1% F.S. THD ≥ 1% V ≥ 10% F.S.V I ≥ 10% F.S.I. TDD: 1.5% F.S. TDD ≥ 1% I ≥ 10% F.S.I. Watts:0.2% reading + 0.02% F.S. (|PF| ≥ 0.5) -10,000,000 to +10,000,000 kW VARs: 0.3% F.S. (|PF| ≤ 0.9) -2,000,000 to +2,000,000 kVAR VAs: 0.2% F.S. (|PF| ≥ 0.5) 0 to +2,000,000 kVA Wh: Class 0.2S as per IEC 62053-22: 2003 -999,999,999 to +999,999,999 MWh VARh: Class 0.2S as per IEC 6205322:2003 -999,999,999 to +999,999,999 MVARh VAh: Class 0.2S as per IEC 62053-22: 2003 0 to 999,999,999 MVAh INPUT SPECIFICATIONS Power Supply: ƒ 85-265V AC/DC universal power supply ƒ 85-265VAC 50/60Hz, 88-290VDC, 10W ƒ Isolation: ƒ Input to output: 3000VAC ƒ Input to ground: 2000VAC ƒ Options: ƒ 12VDC: 10-16VDC ƒ 24VDC: 18-36VDC ƒ 48VDC: 36-72VDC Voltage: Direct Input: Up to 400V-ln/690V-ll Input impedance: 500 kΩ PT Ratio: 1.0-6500 Range: 1-999,000V Burden: <0.4VA for 400VAC <0.04VA for 120VAC Overload withstand: 1000VAC continuous, 2000VAC for 1 second Galvanic Isolation: 3500VAC Wire size: Up to 12AWG (2.5mm2) Current: 5A secondary: Operating Range: Continuous 10A RMS Burden: < 0.1VA Overload: 15A continuous 300A RMS for 1 second SATEC INC: PM172 Rev. March 2007 1A secondary: Operating Range: Continuous 2A RMS Burden: < 0.02VA Overload: 6A continuous 80A RMS for 1 second CT Ratio: 1-50,000A Range: 0-60,000A Galvanic Isolation: 3500VAC Wire size: Up to 12AWG (2.5mm2) Digital Inputs: ƒ 2 dry contact digital inputs ƒ Internal supply: 15V ƒ Scan time: 1ms ƒ Isolation: 2000V RMS ƒ Wire size: Up to 14AWG (1.5mm2) Analog Inputs (optional): ƒ 2 optically isolated analog inputs ƒ 0-1mA (100% overload) ƒ ±1mA (100% overload) ƒ 0-20mA ƒ 4-20mA ƒ Accuracy: 0.5% F.S. ƒ Scan time: 1 cycle ƒ Isolation: 2000V RMS ƒ Wire size: Up to 14AWG (1.5mm2) OUTPUT SPECIFICATIONS Relay Outputs: ƒ 2 Form A relays for alarming and control ƒ 3A @ 250VAC/30VDC ƒ Galvanic Isolation: ƒ 2000VAC/1min. between contacts and coil ƒ 1000VAC between open contacts ƒ Operate time: 10 ms max. ƒ Release time: 5 ms max. ƒ Update time: 1 cycle Analog Outputs (optional): ƒ 2 optically isolated analog outputs ƒ ±1mA, max. load 5kΩ (100% overload) ƒ 0-20mA, max. load 510Ω ƒ 4-20mA, max. load 510Ω ƒ 0-1mA, max. load 5kΩ (100% overload) ƒ Accuracy 0.5% F.S. ƒ Update time: 1 cycle ƒ Isolation: 2000V RMS ƒ Wire size: Up to 14 AWG (1.5mm2) COMMUNICATION: 2 independent and simultaneous connections COM1 ƒ Standard ƒ Optically isolated RS-232/422/485 ƒ Isolation: 2000V RMS ƒ Selectable baud rate to 115,200 maximum ƒ 7/8 bit even parity or 8 bit no parity ƒ Protocols supported: Modbus RTU & ASCII, and DNP3.0 ƒ Optional Ethernet ƒ Transformer-isolated 10/100BaseT ƒ Connector: RJ45 ƒ Protocols supported: Modbus TCP, DNP3/TCP ƒ 2 simultaneous connections ƒ Optional Dial-up Modem ƒ Transformer-isolated 56KB modem ƒ Connector: RJ11 ƒ Protocols supported: Modbus RTU ƒ Optional Profibus DP (IEC 61158) ƒ RS-485 optically isolated Profibus interface ƒ Baud rate: 9600 - 12Mbps auto detection ƒ 32 bytes input, 32 bytes output ƒ Protocol supported: Profibus DP COM2 ƒ Optically isolated RS-422/RS-485 port ƒ Isolation: 2000V RMS ƒ Connector: 5-pin removable connector ƒ Selectable baud rate up to 115,200 ƒ 7/8 bit even parity or 8 bit no parity ƒ Protocols supported: Modbus RTU & ASCII, and DNPV3.0 ƒ Wire size: up to 14 AWG (1.5mm²) Real-time clock: ƒ Accuracy: 15 seconds per month @ 25°C (25 PPM) Log Memory (E Model): ƒ 1MB on-board memory with battery backup Standards of Compliance: UL Recognized – E129258 UL61010B-1 CE EMC: 89/336/EEC as amended by 92/31/EEC and 93/68/EEC LVD: 73/23/EEC as amended by 93/68/EEC and 93/465/EEC Harmonized standards to which conformity is declared: EN EN55011: 1991; EN 50082-1: 1992 EN61010-1: 1993; A2/1995 EN50081-2: 1994 Generic Emission Standard – Industrial Environment EN50082-2: 1995 Generic Immunity Standard – Industrial Environment EN55011:1994 Class A EN61000-4-2: 1995 Electrostatic Discharge EN61000-4-4: 1995 Electrical Fast Transient EN61000-4-8: 1993 Radio AMFrequency Electromagnetic Field, ENV50140: 1995 (200Hz) RF Electromagnetic Field, Pulse Modulated ENV50204: 1995 (900MHz) ENV50141: 1993 RF Common Mode AM ANSI C37.90.1: 1989 SWC ANSI C62.41: 1991 Standard Surge Enhanced PM172-N Series Advanced FEEDER Monitor Construction Case enclosure: Plastic PC/ABS blend Display body: Plastic PC/ABS blend Front panel: Plastic PC PCB: FR4 (UL94V0) Terminals: PBT (UL94-V0) Plug-in connectors: Polyamide PA6.6 (UL94-V0) Dimensions: 5x5x5.8” (127x127x147mm) Mounting: ANSI 4” round DIN 92x92mm cutout Weight: 1.23kg (2.7 lb.) MODELS AND MEASUREMENTS MISCELLANEOUS PM172-N SERIES ADVANCED FEEDER MONITOR PM172P–NPM172E–N- Measurements Options: VOLTAGE INPUTS 0 400V-LN/690V-LL Nominal U 120V-LN/208V-LL Nominal CALIBRATION 25HZ 25Hz 50HZ 50Hz 60HZ 60Hz 400HZ 400Hz CURRENT INPUTS 5 5 Amps 1 1 Amps POWER SUPPLY AC/DC 85-265VAC/85-290VDC 1DC 10-18 VDC 2DC 18-36 VDC 3DC 38-72 VDC ANALOG OUTPUT OR INPUT 00 No Analog Output Analog Output AO1 ±1mA AO2 0-20mA AO3 0-1mA AO4 4-20mA Analog Input AI1 ±1mA AI2 0-20mA AI3 0-1mA AI4 4-20mA COM1 00 RS232/422/485 MOD Dial up modem 56K ETH Ethernet PRO Profibus EXAMPLES: PM172P-U-60HZ-5-ACDC-AO4-ETH PM172E-U-50HZ-1-2DC-AI3-MOD SATEC, INC. 10 Milltown Court, Union, NJ, 07083 US Toll Free: 1-888-OK-SATEC Tel: +1 (908) 686-9510 Fax: +1 (908) 686-9520 Email: [email protected] www.oksatec.com SATEC INC: PM172 Rev. March 2007 Voltage L-L per phase Voltage L-N per phase Current per phase Neutral current Frequency Phase Rotation Relay Status Counters TxD, RxD Comm Status Alarm Trigger Code PF per phase and total kW per phase and total KVAR per phase and total KVA per phase and total Voltage Unbalance Current Unbalance %THD Volts per phase %THD Amps per phase %TDD Amps per phase K-Factor per phase Fundamental Volts, Amps per phase Fundamental kW, kVAR, kVA per phase & total Displacement PF per phase and total Voltage & Current Phasors Volts Demands Amps Demands kW, kVAR, kVA Demands V, I THD Demands kWh Imp/Exp, per phase & total kVARh Imp/Exp, per phase & total kVAh per phase and total TOU parameters 16 Data Logs 1 Event Log Internal memory PM172-N P E ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■