A-1 AC 230V/120V INPUT 50/60Hz 1 2 2 1 3 4 L G V+ AC AC V- V- AC AC V+ S D 4 3 1 2 1 2 CURRENT CONTROL DC AIR OT A 1 2 DRIVE SIGNAL 7 6 5 4 3 2 1 1 2 U_D G G +15V-15V S G +15V-15V S G S D 2 1 3 2 1 + - S G 6 5 4 3 2 1 XFIF/IN/OUT FEEDBACK SIGNAL 1 2 3 4 1 2 3 4 1 2 3 4 1 2 HFOUT N/A +24V D 3 2 1 3 2 1 Rev G S Revision 1 2 3 4 + - S G 2 1 2 1 D_port 4 3 2 1 + HF/QF + WV OUTPUT WV OUTPUT 1 2 DC 24V TRANSF IFB 5 4 3 2 1 SOURCE&TIP FEEDBACK SIGNAL 7 6 5 4 3 2 1 DRIVE SIGNAL 5 4 3 2 1 1 2 D + Manual 0-5141 S - POWER 1 2 3 1 2 TEST 1 2 3 4 By PP I Date WEST LEBANON,NH03784 INDUSTRIAL OARK NO.2 THERMAL DYNAMICS WORK SW TITLE: NOTE: SCHEMATIC CUTMASTER 42 230V SINGLE PHASE 50/60Hz Unless otherwise Specified resistors are in Ohms 1/4W 5% Capacitors are in Microfarads (UF) Information proprietary to THERMAL DYNAMICS CORPORATION Not for Release Reproduction or Distribution without writeen consent A THERMADYNE Company 603-298-5711 PILOT T O R C H OVER TEMPERATURE PRESSURE SW TORCH SW GAS SOLENOID cutmaster 42 APPENDIX 1: CUTMASTER 42 CIRCUIT DIAGRAM Art # A-09396_AF APPENDIX cutmaster 42 APPENDIX 2: SL40 TORCH PIN-OUT DIAGRAM A. Hand Torch Pin-Out Diagram Negative / Plasma 8 - Open 4 - Green / Switch 3 - Yellow / Switch ATC Female Receptacle Front View ATC Male Connector Front View 8 - Ground 4 - Switch 4 3 1&2- Shorted Blue / PIP 2 1 6 5 8 7 7 - Open 7 - Open 6 - Open 6 - Open 8 7 5 - Open 5 - Open 6 5 2 1 4 3 3 - Switch 2 - PIP 1 - PIP Pilot Pilot APPENDIX Negative / Plasma Art # A-11809 A-2 Manual 0-5141