Preview only show first 10 pages with watermark. For full document please download

Thermal Interface Units - Reliance Water Controls

   EMBED


Share

Transcript

THERMAL INTERFACE UNITS Designed and manufactured in the UK Designed for performance THE BENEFITS ARE ALL IN THE NAME DEPENDABILITY From the instant we first started supplying the plumbing market and hot water system manufacturers in 1986, Reliance Worldwide Corporation (UK) Ltd. has been the last word in dependability. We are part of Reliance Worldwide Corporation (Aus) Pty Ltd. who are global specialists dedicated to improving and delivering worldleading pressure, temperature and flow control products. INNOVATION Reliance Worldwide Corporation (UK) Ltd. has been, and always will be, at the forefront of innovative and dynamic end-to-end plumbing and heating solutions. With an impressive track record for developing market-leading thermostatic technology in the UK, we owe it all to our customers. By actively listening to and identifying their needs, then developing products to meet and surpass them, we have a formidable reputation for true innovation. 2 RELIABILITY Reliance Worldwide Corporation (UK) Ltd. is all about steadfast reliability. Buy Reliance Worldwide Corporation (UK) Ltd. products once, experience genuine reliability and you become a customer for life. We also offer comprehensive warranties as we have such proven faith in the quality, performance and ultimately the reliability of our products. SIMPLICITY Cutting edge technology is used to design and create Reliance Worldwide Corporation (UK) Ltd. products, with ease of installation and minimisation of maintenance being a key aim. A high quality reliable product that is simple to install not only satisfies customers, it speeds up fitting time. Anything that can make the installer’s job easier and faster can only have a positive effect on reducing cost. QUALITY Every Reliance Worldwide Corporation (UK) Ltd. product is manufactured to the highest standards using pioneering techniques and only the very highest quality materials. Our reputation is built on premium quality and high performance. Knowing this, our customers appreciate the convenience of being able to turn to a single supplier to access a truly comprehensive range of ultra-reliable plumbing and heating products. Reliance Worldwide Corporation (UK) Ltd. is an accredited manufacturer to the following International Standards. THERMAL INTERFACE UNITS (TIUs) Radiance® TIUs from Reliance Worldwide Corporation (UK) Ltd. offer the perfect solution as they can be adapted to exact requirements when an instantaneous or stored hot water system is required in a Community Heating Network installation. As a leading supplier to the UK heating industry for many years, we have gained a wealth of knowledge and experience in the design and production of innovative products. The Reliance Water Controls brand is recognised for quality and reliability and our TIUs, created specifically to suit UK systems, have been designed, manufactured and tested to ensure they provide the same high levels of satisfaction and longevity. We understand that no two project requirements are the same, that is why we provide a dedicated technical and design support service to work alongside you. This enables us to develop custom-built solutions to meet the exacting needs of your project. We won’t just focus on the TIUs, we will ensure your whole system operates as effectively and efficiently as possible to meet every demand. Our Radiance TIUs are manufactured in the UK ensuring lead times are minimal and deliveries can be made to suit a site’s requirements. Designed and manufactured in the UK CONTENTS What is a TIU And How Does It Work? 4 High Efficiency Solution for community networks 5 Radiance Range Overview 6 Radiance Features and Benefits 8 Rapid Specification 10 Swift Specification 11 Active Specification 12 Zest Specification 13 Spirit Specification 14 Chill Specification 15 Optional Extras 16 Diversity Charts 18 System Design 21 Conformance and Approvals 21 Guarantee 21 Related Products Tel: +44 (0)1386 712 400 22 Email: [email protected] 3 WHAT IS A TIU AND HOW DOES IT WORK? TIUs form part of a community heating network (CHN) that provides central heating and domestic hot water to individual properties or apartments within a single development. Traditionally in the UK, housing stocks have been built with individual gas combi boilers located in each apartment. Conversely, across mainland Europe Community Heating Networks - (or District Heating Systems as they were previously known), have long been the solution to provide heating and hot water in large community developments, with a centralised energy centre coupled with a low temperature hot water network. In recent years we have seen a resurgence of CHN developments in the UK as the available technology improves and becomes more popular in helping comply with current legislation for energy efficiency and reduced emissions. Community heating networks operate from a single energy source (the energy centre) that distributes energy in the form of hot water circulating within a primary network throughout a building or housing development. Each individual house or apartment has a secondary network which is connected to the primary network via a thermal interface unit that heats DHW and space heating water via plate heat exchangers to meet the individual demands of the property. Typical apartment type installation ENERGY CENTRE Domestic Hot Water Domestic Hot Water Return Flow Mains Water Supply Typical housing development installation 4 ENERGY CENTRE 1 1. Ball Valves 2. Strainers 3. Diverter Valve 4. Plate Heat Exchanger - Heating (under expansion vessel) 5. Circulation Pump 6. Heat Meter 7. Differential Pressure Control Valve 8. Thermostatic Bypass Valve 9. Primary Zone Valve - Heating 10. Patented Spring Loaded Maintenance Free Expansion Vessel 11. Over Pressure Relief Valve with Pressure Gauge 12. Plate Heat Exchanger - DHW 13. Thermostatic Mixing Valve 14. Flow Sensor - DHW 6 5 2 2 13 14 7 11 18 8 17 15 9 15. Thermostatic Heating Control Valve 16. Wiring Box 16 17. Product Information Label 18. Insulated Stainless Steel Pipework 4 12 3 10 HIGH EFFICIENCY SOLUTION FOR COMMUNITY HEATING NETWORKS ✔ The absence of gas throughout the building avoids the cost of testing/regulations for installing gas ✔ The absence of flues saves cost and allows for an aesthetically pleasing building exterior ✔ No planning constraints ✔ Simple design; reduced maintenance ✔ Easily integrated with renewable heat sources if desired (CHP, biomass, heat pump, solar) ✔ Ultra-safe well-known technology using only low pressure hot water ✔ Individual metering options available, including automatic meter reading or a prepayment meter Tel: +44 (0)1386 712 400 Email: [email protected] 5 RANGE OVERVIEW The Radiance® Thermal Interface Units range comprises six base models. Three instantaneous hot water units, two stored water units and a cooling unit. Our comprehensive range is designed to suit any project requirements. A number of optional extras are also available to suit your exact needs. Please see page 16 - 17. Rapid BUILDING T V A Description Indirect heating + instantaneous DHW Secondary Return SF Secondary Flow DHW Domestic Hot Water TVA Tenant Valve Assembly DHW SR MAINS COLD WATER PRIMARY RETURN SF PRIMARY FLOW Twin plate heat exchanger unit to generate instantaneous DHW with indirect heating connections. SR APARTMENT RAD RAD Swift BUILDING T V A Description Direct heating + instantaneous DHW Secondary Return SF Secondary Flow Domestic Hot Water TVA Tenant Valve Assembly DHW SR MAINS COLD WATER PRIMARY RETURN SF PRIMARY FLOW Single plate heat exchanger to generate instantaneous DHW with direct heating connections. SR DHW APARTMENT RAD RAD SWIFT TIU Active Instantaneous DHW Tenant Valve Assembly DHW PRIMARY RETURN PRIMARY FLOW Single plate heat exchanger to generate instantaneous domestic hot water only. APARTMENT ACTIVE TIU 6 Domestic Hot Water TVA BUILDING T V A MAINS COLD WATER Description DHW Instantaneous Hot Water RAPID TIU BUILDING T V A SR Secondary Return SF Secondary Flow DHW Domestic Hot Water TVA Tenant Valve Assembly SR SF Description Indirect heating + pre-plumbed cylinder stored DHW APARTMENT MAINS COLD WATER PRIMARY RETURN PRIMARY FLOW Stored Hot Water DHW Zest RAD RAD Single plate heat exchanger unit to generate indirect heating. PRE PLUMBED CYLINDER ZEST TIU BUILDING T V A SR Secondary Return SF Secondary Flow DHW Domestic Hot Water TVA Tenant Valve Assembly SR SF Description Indirect heating + standard cylinder water storage APARTMENT MAINS COLD WATER PRIMARY RETURN PRIMARY FLOW DHW Spirit RAD STANDARD CYLINDER RAD Single plate heat exchanger unit to generate indirect heating. BUILDING SR Secondary Return SF Secondary Flow FCU Description Cooling/Air conditioning APARTMENT MAINS COLD WATER PRIMARY FLOW SR Tel: +44 (0)1386 712 400 Chill Fan Coil Unit SF PRIMARY RETURN Chilled Water SPIRIT TIU FCU A single plate cooling unit for air conditioning. FCU CHILL TIU Email: [email protected] 7 FEATURES AND BENEFITS: Designed for high efficiency performance •  Designed and manufactured in the UK to be fully compatible with UK heating and hot water systems •  Highly energy efficient CHN systems are more eco-friendly and economical than alternative heating methods over system lifetime •  Radiance TIUs are ‘Demand Controlled’ so there is only flow through the unit when there is a requirement for heat or DHW, which reduces unnecessary heat loss, lime-scale build-up and supports whole system longevity •  All internal pipe work is manufactured from high quality, flexible, fully insulated corrugated stainless steel pipes which reduce heat loss and permit bespoke configurations to be made with ease •  WRAS approved Options to suit individual projects •  Radiance TIUs can be configured with a number of optional extras to suit any individual projects requirements. Reliance Worldwide Corporation (UK) Ltd offer a system design support service to help Architects and Specifiers to ensure maximum energy efficiency is achieved for their projects •  Individual metering options include automatic meter reading or a prepayment type meters for minimal disruption to occupants. A meter reading service can also be provided via a partner organisation if required 8 Easy to install and commission •  The absence of gas or flues increase safety for occupants and reduces whole system installation costs in terms of both materials and labour time •  Connections are made easy with SharkBite® push-fit ball valve connectors for an even faster installation. Ball valves with female BSP connections are also available if required •  Each unit is delivered fully factory assembled and is 100% leak tested prior to despatch to ensure product performance and reduce commissioning time •  The absence of soldered or brazed joints minimises contamination and leak potential eliminating the requirement for flushing prior to commissioning Reduced maintenance •  All pipe connections are union fittings sealed with washers for reliable joints and easy maintenance •  Radiance TIUs incorporate a patented spring loaded expansion vessel which delivers a high performance compact size unit with extended product lifetime which is entirely maintenance free •  Each unit is marked with a unique serial number, product code and production date to ensure individual product identifications/traceability for maintenance records Tel: +44 (0)1386 712 400 Email: [email protected] 9 RAPID SPECIFICATION Indirect Heating and Instantaneous Domestic Hot Water Unit Weight Pressure Rating 45 (approx.) Kg Primary (max) 10 bar Secondary (max) 3 bar Cold water mains (min) 2 bar Cold water mains (max) 4 bar Primary (min) 65 °C Primary (max) 95 °C Domestic hot water 30-60 °C Differential Pressure Primary (max) 2.5 bar Primary (min) 0.5 bar DPCV Factory set 0.3 bar Heat Transfer Capacity Heating circuit 15 kW *Higher kW available DHW circuit 42 (Std.)* kW DHW Flow Rate Temp. rise from 10°-50° 15 l/min Circulation Pump Branded A rated Pump head 6m External Connections Primary flow 22mm PF or ¾" FBSP Primary return 22mm PF or ¾" FBSP Secondary flow 22mm PF or ¾" FBSP Secondary return 22mm PF or ¾" FBSP Boosted cold water 22mm PF or ¾" FBSP Domestic hot water 22mm PF or ¾" FBSP Adjustable 30-60 Temperature Standard body 130mm(L) with 1½” connections Thermostatic Bypass A. 840mm B. 505mm C. 265mm °C C INTERNAL SYSTEM COMPONENTS 2 3 M 1A - Primary Flow (PF) 1B - Primary Return (PR) 1C - Secondary Flow (SF) 1D - Secondary Return (SR) 1E - Domestic Hot Water (DHW) 1F - Boosted Cold Water (BCW) 2. Strainers 3. Diverter Valve for DHW 1C 5 T 4 PF 8 HM SF 2 M 7 5. Circulation Pump Heating System 7. Differential Pressure Control Valve 1D SR 6 4. Plate Heat Exchanger - heating 6. Heat Meter (optional) 11 10 PR 1B B 1. Ball Valve Connections 15 1A A 8. Thermostatic By-pass Valve (optional) 9. Primary Zone Valve - Heating 9 12 TMV 13 1E DHW 14 1F BCW 10. Patented Spring Loaded Maintenance Free Expansion Vessel 11. Overpressure Relief Valve with Pressure Gauge 12. Plate Heat Exchanger DHW 13. Thermostatic Mixing Valve DHW (optional) 14. Flow Sensor DHW 10 15. Thermostatic Heating Control Valve (THCV) (optional) SWIFT SPECIFICATION Direct Heating and Instantaneous Domestic Hot Water Unit Weight Pressure Rating 35 (approx.) Kg Primary (max) 10 bar Secondary (max) 10 bar Cold water mains (min) 2 bar Cold water mains (max) 4 bar Primary (min) 65 °C Primary (max) 95 °C Domestic hot water 30-60 °C Differential Pressure Primary (max) 2.5 bar Primary (min) 0.5 bar DPCV Factory set 0.3 bar Heat Transfer Capacity Heating circuit 15 kW *Higher kW available DHW circuit 42 (Std.)* kW DHW Flow Rate Temp. rise from 10°-50° 15 l/min External Connections Primary flow 22mm PF or ¾" FBSP Primary return 22mm PF or ¾" FBSP Secondary flow 22mm PF or ¾" FBSP Secondary return 22mm PF or ¾" FBSP Boosted cold water 22mm PF or ¾" FBSP Domestic hot water 22mm PF or ¾" FBSP Adjustable 30-60 Temperature Thermostatic Bypass A. 840mm B. 505mm C. 265mm °C C INTERNAL SYSTEM COMPONENTS 1A 2 3 1A - Primary Flow (PF) 1B - Primary Return (PR) 1C - Secondary Flow (SF) 1D - Secondary Return (SR) 1E - Domestic Hot Water (DHW) 1F - Boosted Cold Water (BCW) 2. Strainers 3. Diverter Valve for DHW SF HM 4. Thermostatic By-pass Valve (optional) 5. Heat Meter (optional) 7 6. Differential Pressure Control Valve 2 M 1D PR 7. Zone Valve Heating SR 1B 5 B 1. Ball Valve Connections 1C M PF 4 A 8. Plate Heat Exchanger DHW 9 6 9. Thermostatic Mixing Valve DHW (optional) 1E TMV DHW 8 10 10. Flow Sensor DHW 1F BCW Tel: +44 (0)1386 712 400 Email: [email protected] 11 ACTIVE SPECIFICATION Instantaneous Domestic Hot Water Unit Weight Pressure Rating Temperature 30 (approx.) Kg Primary (max) 10 bar Cold water mains (min) 2 bar Cold water mains (max) 4 bar Primary (min) 65 °C Primary (max) 95 °C Domestic hot water 30-60 °C Primary (max) 2.5 bar Primary (min) 0.5 bar DPCV Factory set 0.3 bar Heat Transfer Capacity DHW circuit 42 (Std.)* kW DHW Flow Rate Temp. rise from 10°-50° 15 l/min External Connections Primary flow 22mm PF or ¾" FBSP Primary return 22mm PF or ¾" FBSP Boosted cold water 22mm PF or ¾" FBSP Domestic hot water 22mm PF or ¾" FBSP Adjustable 30-60 Differential Pressure *Higher kW available Thermostatic Bypass °C A. 840mm B. 505mm C. 265mm C INTERNAL SYSTEM COMPONENTS A B 1. Ball Valve Connections 1A 1B 1C 1D - Primary Flow (PF) Primary Return (PR) Domestic Hot Water (DHW) Boosted Cold Water(BCW) 2. Strainer 3. Primary Control Valve 4. Plate Heat Exchanger 2 1A 3 5 M 4 PF 5. Thermostatic Blending Valve DHW (optional) 1C TMV DHW 6. Heat Meter (optional) 7. Differential Pressure Control Valve 8. Thermostatic By-pass Valve (optional) 8 9. Flow Sensor DHW HM PR BCW 1B 12 6 7 9 1D ZEST SPECIFICATION Indirect Heating & Domestic Hot Water Unit linked to a Pre-plumbed Cylinder Weight 25 (approx.) Kg Primary (max) 10 bar Secondary (max) 3 bar Temperature Primary (max) 95 °C Secondary (max) 90 °C Differential Pressure Primary (max) 2.5 bar Primary (Min) 0.5 bar DPCV Factory Set 0.3 bar Heat Transfer Capacity (At dt=30k and flow=571l/hr) 20 kW External Connections Primary flow 22mm PF or ¾" FBSP Primary return 22mm PF or ¾" FBSP Secondary flow 22mm PF or ¾" FBSP Secondary return 22mm PF or ¾" FBSP Pressure Rating A. 840mm B. 505mm C. 265mm C INTERNAL SYSTEM COMPONENTS A B 1. Ball Valve Connections 1A 1B 1C 1D - Primary Flow (PF) Primary Return (PR) Secondary Flow (SF) Secondary Return (SR) 2. Strainer 3. Zone Valve 4. Thermostatic Control Valve (optional) 1A 2 3 M 4 6. Heat Meter (optional) T 5 PF 5. Plate Heat Exchanger 1C SF 7. Differential Pressure Control Valve HM PR SR 1B 6 7 Tel: +44 (0)1386 712 400 1D Email: [email protected] 13 SPIRIT SPECIFICATION Indirect Heating & Domestic Hot Water Unit linked to a Standard Cylinder Weight 35 (approx.) Kg Primary (max) 10 bar Secondary (max) 3 bar Temperature Primary (min) 65 °C Primary (max) 95 °C Differential Pressure Primary (max) 2.5 bar Primary (min) 0.5 bar DPCV Factory set 0.3 bar Heat Transfer Capacity Heating circuit 15 kW Circulation Pump Branded A rated Pump head 6m External Connections Primary flow 22mm PF or ¾" FBSP Primary return 22mm PF or ¾" FBSP Secondary flow 22mm PF or ¾" FBSP Secondary return 22mm PF or ¾" FBSP Adjustable 40-70 Pressure Rating *Higher kW available Standard body 130mm(L) with 1½” connections Thermostatic Heating Control °C A. 840mm B. 505mm C. 265mm C INTERNAL SYSTEM COMPONENTS A B 1. Ball Valve Connections 1A 1B 1C 1D - Primary Flow (PF) Primary Return (PR) Secondary Flow (SF) Secondary Return (SR) 2. Strainers 3. Thermostatic Heating Control Valve (optional) 4. Plate Heat Exchanger 2 1A 3 5 T 4 PF 5. Circulation Pump Heating System 1C SF 6. Heat Meter (optional) 7. Differential Pressure Control Valve 8. Zone Valve Heating 10 9. Expansion Vessel M HM PR SR 1B 14 6 7 8 9 2 1D 10. Overpressure Relief Valve With Pressure Gauge CHILL SPECIFICATION Cooling/Air Conditioning Unit Weight 35 (approx.) Kg Primary (max) 10 bar Secondary (max) 3 bar Temperature Primary (min) 5 °C Primary (max) 15 °C Differential Pressure Primary (max) 2.5 bar Primary (min) 0.6 bar DPCV Factory set 0.3 bar Heat Transfer Capacity Cooling circuit 4 kW Circulation Pump Branded A rated Pump head 6m External Connections Primary flow 22mm PF or ¾" FBSP Primary return 22mm PF or ¾" FBSP Secondary flow 22mm PF or ¾" FBSP Secondary return 22mm PF or ¾" FBSP Pressure Rating *Higher kW available Standard body 130mm(L) with 1½” connections A. 840mm B. 505mm C. 265mm C INTERNAL SYSTEM COMPONENTS A B 1. Ball Valve Connections 1A 1B 1C 1D - Primary Flow (PF) Primary Return (PR) Secondary Flow (SF) Secondary Return (SR) 2. Strainers 3. Energy Meter (optional) 4. Plate Heat Exchanger 5. Differential Pressure Control Valve 2 1A 8 1C 4 PF 6. Zone Valve Cooling SF 7. Expansion Vessel 8. Circulation Pump Cooling System 9. Overpressure Relief Valve With Pressure Gauge 9 M HM PR SR 1B 3 5 Tel: +44 (0)1386 712 400 6 7 2 1D Email: [email protected] 15 OPTIONAL EXTRAS Radiance® Thermal Interface Units are designed and manufactured to your individual project requirements. We offer a choice of optional extra components which can be included during assembly to meet your exact specification needs. Our in-house engineering department is available for advice on specification, system design and efficiency. First Fix Rail (FFR) A first fix rail permits phased installation of the unit and is supplied complete with ball valves to allow for pipework to be pre-installed independent of the main TIU. The packaging also includes a handy fixing template to aid the drilling of fixing holes in the correct location. The pipe work can be flushed and pressure tested, before the unit is installed and connected to the system. The FFR is available with or without a flushing bypass valve on the primary side. Ball Valves Connections are made easy with SharkBite push-fit connectors (as standard). Female BSP connections are also available, if required. For more information on SharkBite push-fit plumbing solutions please visit www.sharkbiteplumbing.co.uk Thermostatic By-Pass Valve (TBPV) The thermostatic by-pass valve ensures that the temperature of the primary flow pipe will not drop below the set point by circulating water through the primary system if necessary. This enables instantaneous DHW to be available quicker than if the system cooled completely. The TBPV will only circulate water when required thus reducing the energy loss of the system. Thermostatic Heating Control Valve (THCV) The thermostatic heating control valve offers better control over the secondary flow temperature and keeps the primary return temperature to a minimum which means the network performs at a higher efficiency. Thermostatic Mixing Valve (TMV) - DHW The thermostatic mixing valve controls the temperature of the DHW and limits it to the set temperature reducing scalding risk. Flushing By-Pass Valve An integrated connection/by-pass valve allows flushing of the network whilst by-passing the thermal interface unit. 16 Ultrasonic Heat Meter An ultrasonic heat meter can be installed within the thermal interface unit to accurately meter energy consumption for billing purposes. The M-Bus interface for remote meter reading is included as standard. Mechanical Heat Meter A mechanical heat meter can be installed as an alternative to an ultrasonic heat meter to also accurately meter energy consumption for billing purposes. The M-Bus interface for remote meter reading is included as standard. Water Meter A water meter can be installed to accurately measure water consumption of both hot and cold water for billing purposes. It also includes a pulse output to enable reading by the heat meter. Meter Reading An M-Bus master unit is available to automatically read all meters on the M-Bus network. A wireless radio meter reading device is also available for manual meter reading. This works in conjunction with an android phone or tablet where information will be saved. Prepayment Unit The prepayment unit takes the reading from the heat meter and will shut off the TIU when there is no credit left. The unit communicates with a central server via GSM (Global System for Mobile Communications). It is also certified as an ENE3 display. A partner company is able to offer a full prepayment solution - please contact us for details. Cover Lock A locking mechanism is available to prevent tampering with the unit settings. Tel: +44 (0)1386 712 400 Email: [email protected] 17 DIVERSITY CHARTS Community heating networks show a high diversity on their domestic hot water (DHW) load. The diversity factor depends on how many units are connected to the network and also on the network layout. The maximum network load can be greatly reduced by including DHW diversity. This allows a reduction in the required pipe size, saving on installation and maintenance cost. The charts below give the load factors depending on the number of units connected to a branch or network. 1,00 0,90 Text Book Diversity Factor 0,80 Diversity Factor based on DIN 4708 0,70 0,60 Diversity Factor based on measurements taken from a working Heating Network 0,50 0,40 Diversity Factor used by other manufacturers 0,30 0,20 0,10 0,00 0 18 20 40 60 80 100 120 140 160 180 200 Number of concurrently drawing Apartments Diversity in 1 - 14 Apartments 3,10 3,00 2,90 2,80 2,70 2,60 2,50 2,40 2,30 2,20 2,10 2,00 1,90 1,80 1,70 1,60 1,50 1,40 1,30 1,20 1,10 1,00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Number of Apartments Diversity in 14 - 45 Apartments 3,90 Number of concurrently drawing Apartments 3,80 3,70 3,60 3,50 3,40 3,30 3,20 3,10 3,00 2,90 2,80 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Number of Apartments Tel: +44 (0)1386 712 400 Email: [email protected] 19 DIVERSITY CHARTS Number of concurrently drawing Apartments Diversity in 45 - 100 Apartments 6,20 6,10 6,00 5,90 5,80 5,70 5,50 5,50 5,40 5,30 5,20 5,10 5,00 4,90 4,80 4,70 4,60 4,50 4,40 4,30 4,20 4,10 4,00 3,90 3,80 3,70 3,60 45 50 55 60 65 70 75 80 85 90 95 100 Number of Apartments Diversity in 100 - 200 Apartments 9,50 Number of concurrently drawing Apartments 9,00 8,50 8,00 7,50 7,00 6,50 6,00 5,50 100 105 110 115 120 125 130 135 140 145 150 155 Number of Apartments 20 160 165 170 175 180 185 190 195 200 SYSTEM DESIGN Reliance Worldwide Corporation (UK) Ltd. offer a system design support service for Architects and Specifiers to consult with UK based engineers who are able to offer advice on effective system design to ensure maximum energy efficiency is achieved. Contact us on the number below. CONFORMANCE AND APPROVALS Conforms to Building regulations part L (2010) WARRANTY Radiance Thermal Interface Units (TIUs) are manufactured in the UK from the highest quality components to ensure reliability and maintain longevity. All Radiance TIUs are supplied fully assembled and leak tested with a 2 year warranty* as standard. *subject to terms and conditions which can be found at www.rwc.co.uk Tel: +44 (0)1386 712 400 Email: [email protected] 21 RELATED PRODUCTS Tenant® Valves Reliance Water Control Tenant Valves are an innovative, compact, 5-in-1 solution for the control and monitoring of incoming water supplies. Ideal for multi-occupancy buildings with several service provisions. Includes PRV, Pressure Gauge, Isolating Valve, Double Check Valve and Water Meter Port. Easy to service and maintain with its cartridge design construction. Significantly reduces leak potential. Saves labour time, cost and saves space. Supplied pre-insulated. Heat Pack The Reliance Water Controls Heat Pack is a useful all in one domestic heating system kit that contains all the common components required on a domestic heating system, including 2 x 22mm Zone Valves, a Wiring Centre, a Two Channel Programmer, a Contact Thermostat and an Electronic Room Thermostat. Components are also available to purchase individually. SharkBite® Fittings, Valves and Pipe SharkBite is the world’s most versatile range of metal push-fit fittings and valves for joining Copper, SharkBite PEX, Carbon Steel and Polybutylene pipes, in any configuration. With no solder, flux or heat required, SharkBite is ideal for applications where flamed jointing is not permitted. All fittings are manufactured from an ultra-low lead DZR brass and are electrically continuous (when used with metal pipe). They are also easily detectable behind stud walls in the event of future works. SharkBite fittings are rated up to 120°C at 10 bar so are ideal to use to connect right up to the TIU. All SharkBite fitting and valves are fully demountable (using a special tool) and are instantly reusable saving additional expense. Heating Controls Reliance Water Controls Touchscreen Programmable Thermostats provide precise temperature control within +/- 1°C and are available in a stylish white or black gloss case to suit any interior decor. The thermostats incorporate an easy to read digital LED display, with seven day programming, with up to six events per day. 22 For further information on any of the products above or to view the full Reliance Worldwide Corporation (UK) Ltd. range, please visit www.rwc.co.uk Harron Valves The Harron Valve, a combined Thermal Balancing and Pressure Reducing Valve is the latest time saving innovation from Reliance Water Controls. This compact, two in one solution, reduces leak potential and the possibility of installation error. It is supplied complete with its own bespoke insulation case further saving time and cost. It is suitable for hot water applications and incorporates a built-in disinfection function to protect against legionella, a dry-fit thermometer, easy to read pressure indicator dial, integral strainer and SharkBite® connectors for even quicker installation. A version is also available with MBSP union connections which permit ease of servicing. Thermal Balancing Valves Reliance Water Controls Thermal Balancing Valves automatically balance and maintain optimum temperatures in potable hot water systems and are supplied complete with their own unique moulded insulation. Fully adjustable with a tamper-proof cap and designed to incorporate a host of benefits including a built-in disinfection function to protect against legionella and a dry-fit push in thermometer which means there is no need to drain down the system for installation. Reliance Thermal Balancing Valves are also available with SharkBite connectors for even quicker installation. Water Meters Reliance Water Controls offer a comprehensive range of silent operation single and multi-jet, water meters for either hot or cold applications. The compact design permits both vertical or horizontal installation. All models incorporate a fully rotational dry dial enabling easy reading of the meter regardless of installation position. Pressure Reducing Valves (PRVs) Reliance Water Controls offer a comprehensive range of drop tight Pressure Reducing Valves suitable for both domestic and commercial, hot and cold water applications. All products in the range utilise a single piece cartridge design, which permits easy maintenance and can be installed in any orientation. Tel: +44 (0)1386 712 400 Email: [email protected] 23 FOR FURTHER INFORMATION OR TO MAKE A PROJECT ENQUIRY, PLEASE CONTACT US: Reliance Worldwide Corporation (UK) Ltd Worcester Road, Evesham Worcestershire WR11 4RA Tel: +44 (0)1386 712 400 Fax: +44 (0)1386 712 401 Email: [email protected] www.rwc.co.uk facebook.com/reliancewatercontrols @RWCUK In the interests of continuous product improvement Reliance Worldwide Corporation (UK) Ltd. reserve the right to alter specifications as necessary. E&OE. Copyright ©2015 Reliance Worldwide Corporation (UK) Ltd. Copyright ©2014 Radiance. All trademarks and registered trademarks are the property of Reliance Worldwide Corporation (UK) Ltd. All rights reserved. ISSUE 1-06/15