Transcript
SAM T R A N S F O R M E R
A C C E S S O R I E S
THERMOMETERS
BIMETAL THERMOMETERS (DIN 16 160 - PART 2) TYPE: MBT
60
20
40
60
80
100
APPLICATION This thermometer is designed for indication of oil temperature in both transformers with expansion conservator or hermetically sealed type transformers. It is fitted with two electric switches and a maximum indicating pointer. The thermometer operates efficiently under very hot and very cold weather conditions.
120
CONSTRUCTION All components are surface treated or made of corrosion resistant materials. The temperature sensing element is a bimetal helix. Setting of the contacts is indicated on the indicating scale. Case transparent plastic window of UV-resistant polycarbonate. Weatherproof according to DIN 40050 protection class IP 43-IP 55. Switches Two micro switches rated at 5 A 250 VAC or 0.2A 250 VDC. Electrically separated switching circuits. The switches close on temperature rise. Insulation tested to ground at 2000 V for 1 minute. Maximum indicating pointer Resettable from the outside by means of a knob. Measuring range Measuring and switching accuracy
70
SWITCH CONNECTION and CONTACT NUMBERING C
20
CONNECTION DIAGRAM Acc. to EN 50005 1 CONTACT ALTERNATIVES NORMALLY OPEN 1 CONTACT
NORMALLY OPEN 1 CONTACT ALARM
TRIPPING
MIN.
MAX.
D
CABLE PRESS PG 16
11 14
21 24
KOD NO: 01
KOD NO: 02
CHANGEOVER 1 CONTACT
CHANGEOVER 1 CONTACT
TRIPPING MAX.
ALARM MIN.
B
A 22 21 24
12 11 14
KOD NO: 03
KOD NO: 04
2 CONTACT ALTERNATIVES NORMALLY OPEN 2 CONTACT ALARM
TRIPPING
MIN.
MAX.
11 14
21 24
KOD NO: 05
TYPES CODE WITHOUT NO CONTACT MT11 MBT0 14 MT21 MBT0 16 MT31 MBT0A 16
ALARM MIN.
TRIPPING MAX.
12 11 14
22 21 24
KOD NO: 06
(When ordering, please indicate the switch connection and numbering type)
E
WITH CONTACT MBTC 14 MBTC 16 MBTCA 16
CHANGEOVER 2 CONTACT
MAIN DIMENSIONS CODE NO MT41 MT51 MT61
A R1"
106 106 106
C
D
117 117 117
12 12 12
15 17 17 MBT / 01
MACHINE-GLASS THERMOMETERS SAM
(DIM 16 160-PART 3) TYPE: MBT T R A N S F O R M E R
7<3(
/
ATE 130
A C C E S S O R I E S
&2'(12
63
MT71
100
MT81
6
0
5
0
4
0
3
0
2
0
1
0
0
0
SW 23
/
A
ØB
- These thermometers are for indoor use. 0$&+,1(*/$667+(5020(7(5 Working liquid Alcohol :RUNLQJOLPLW& & ,PPHUVLRQOHQJWK/ 63-100mm &RQQHFWLRQGLDPHWHU$ R½" Bulb diameter (B) dia. : 12
MBT / 02
SAM
LIQUID FILLED THERMOMETERS NOMINAL SIZE 100mm T R A N S F O R M E R
A C C E S S O R I E S
OPERATING RANGE: Use 3/4 of full scale, short time peaks up to the full scale.
CONSTRUCTIVE SPECIFICATIONS: Thermowell Connection: R1/2" Stainless steel. Movement: Brass for precision clockwork. Sensor Tube: Steel material. Capillary Tube: Steel material. Pointer:0LFURPHWULF&DOLEUDWHG Case: Steel,Black enamel. Front ring:&KURPHSODWHGVWHHO Window: Glass.
MEASURING RANGE:-&&& &&&&&& CAPPILARY LENGTH: 3 and 5 meters. Other measuring units can be printed on the dial, depending on the requirements.
TECHNICAL SPECIFICATIONS: Accuracy: 1.0% F.S.,(DIN 16203) Mounting: Thermowell is mounted to the place where it is going to measure the temperature. Thermometers are calibrated according to the DIN 16203. The base HQYLURQPHQWWHPSHUDWXUHLV&7KHHQYLURQPHW temperature of the capilary tube and the case of the WKHUPRPHWHULVDGYLVHGQRWWREHRYHU&RIWKDW calibration temperature. Ø60 10
29
Ø100
100
53.5
17.5 3
6
3.5 5.5
116 132
Ø10
U
SW.24 &
/
-30+60
203
120
203
160
168
200
168
3m
250
168
5m
300
U
/
203
120
203
160
168
200
168
3m
250
168
5m
168
300
168
350
168
350
168
400
168
400
168
500
168
500
168
%DFN)ODQJH%RWWRP4XWOHW Nr:100601 :(,*+7JU
L
-30+60
R1/2"
U
U
R1/2"
L
15
&
116 132
15
SW.24
6 3
Ø10
)URQW)ODQJH%RWWRP4XWOHW Nr:100602 :(,*+7JU
TO ORDER 1U6FDOH&DSLODU\OHQJWK/4XDQWLW\
MBT / 03
SAM
LIQUID FILLED THERMOMETERS NOMINAL SIZE 160mm T R A N S F O R M E R
CONSTRUCTIVE SPECIFICATIONS: Thermowell Connection: R 1/2 " Stainless stell. Movement: Brass for precision clockwork. Sensor Tube: Steel material. Cappilary tube: Steel material. Pointer:0LFURPHWULF&DOLEUDWHG Case: Steel, Black enamel. Front ring:&KURPHSODWHGVWHHO Window: Glass
A C C E S S O R I E S
OPERATING RANGE: Use 3/4 of full scale, short time peaks up to the full scale MEASURING RANGE:&&& &&&&& CAPPILARY LENGHT: 3 and 5 meters Other measuring units can be printed on the dial, depending on the requirements.
TECHNICAL SPECIFICATIONS: Accuracy: 1.0%F.S., (DIN 16203) Mounting: Thermowell is mounted to the place where it is going to measure the tempereture. Thermometer are calibrated according to the DIN 16203 .The base HQYLURQPHQWWHPSHUDWXUHLV&7KHHQYLURQPHQW temperature of the cappilary tube and the case of the WKHUPRPHWHULVDGYLVHGQRWWREHRYHU&RIWKDW calibration temperatures 60
60
31.5
Ø160
Ø160
10
17.5
SW.24
190
6.5 10.5
6 176 196 L
176
L
15
SW.24
3
5.5
15
3
U Ø10
%DFN)ODQJH%RWWRP4XWOHW Nr: 160601 :(,*+7JU
U 203 203 168 168 168 168 168 168 168
/
R1/2" U
R1/2"
& -30+60 120 160 200 250 300 350 400 500
3m 5m Ø10
& -30+60 120 160 200 250 300 350 400 500
U 203 203 168 168 168 168 168 168 168
/
3m 5m
)URQW)ODQJH%RWWRP4XWOHW Nr: 160602 :(,*+7JU
1U6FDOH&DSLODU\OHQJWK/4XDQWLW\
MBT / 04
SAM
LIQUID FILLED THERMOMETERS WITH ELECTRICAL NOMINAL SIZE 10mm T R A N S F O R M E R
CONSTRUCTIVE SPECIFICATIONS: 7KHUPRZHOO&RQQHFWLRQ56WDLQOHVVVWHHO Movement: Brass for precision clockwork. Sensor Tube: Steel material. Capillary Tube: Steel material. Pointer:0LFURPHWULF&DOLEUDWHG Case: Steel, Black enamel. Front ring:&KURPHSODWHGVWHHO Window: Glass.
23(5$7ù1*5$1*(Use 3/4 of full scale, short time peaks up to the full scale. MEASURING RANGE:&& &&&&&&& CAPPILARY LENGTH: 3 and 5 meters. Other measuring units can be printed on the dial, depending on the requirements.
TECHNICAL SPECIFICATIONS: Accuracy: 1.0 % F.S.,(DIN 16203) Mounting: Thermowell is mounted to the place where it is going to measure the temperature. Thermometers are calibrated according to the DIN 16203. The base HQYLURQPHQWLV&7KHHQYLURQPHQWWHPSHUDWXUH of the capillary tube and the case of the thermometer is DGYLVHGQRWWREHRYHU&RIWKDWFDOLEUDWLRQWHPSHUDWXUH 90
100 50
A C C E S S O R I E S
38
91.5 53.5
31
29
10
17.5 3
3
3.5 5.5
6 15
L Ø10
& -30+60 120 160 200 250 300 350 400 500
U 203 203 168 168 168 168 168 168 168
R1/2"
/
3m 5m Ø10
& -30+60 120 160 200 250 300 350 400 500
U 203 203 168 168 168 168 168 168 168
/
3m 5m
)URQW)ODQJH%RWWRP4XWOHW
%DFN)ODQJH%RWWRP4XWOHW 'RXEOH&RQWDFW1U.
116 132
SW.24
U
U
R1/2"
6
L
15
SW.24
116 132
Weight :1220 gr
'RXEOH&RQWDFW1U.
Weight :1220 gr
TO ORDER 1U6FDOH&RQWDFW7\SH&DSSLODU\OHQJ/4XDQWLWO\ MBT / 05
SAM
LIQUID FILLED THERMOMETERS WITH ELECTRICAL NOMINAL SIZE 160mm T R A N S F O R M E R
CONSTRUCTIVE SPECIFICATIONS: 7KHUPRZHOO&RQQHFWLRQ56WDLQOHVVVWHHO Movement: Brass for precision clockwork. Sensor Tube: Steel material. Capillary Tube: Steel material. Pointer0LFURPHWULF&DOLEUDWHG Case: Steel, Black enamel. Front ring:&KURPHSODWHGVWHHO Window: Glass.
A C C E S S O R I E S
OPERATING RANGE: Use 3/4 of full scale, short time peaks up to the full scale. MEASURING RANGE:&&& &&&&&& CAPPILARY LENGTH: 3 and 5 meters. Other measuring units can be printed on the dial, depending on the requirements.
TECHNICAL SPECIFICATIONS: Accuracy: 1.0 % F.S.,(DIN 16203) Mounting: Thermowell is mounted to the place where it is going to measure the temperature. Thermometers are calibrated according to the DIN 16203. The base HQYLURQPHQWLV&7KHHQYLURQPHQWWHPSHUDWXUH of the capillary tube and the case of the thermometer is DGYLVHGQRWWREHRYHU&RIWKDWFDOLEUDWLRQWHPSHUDWXUH 119
38
10
Ø160
Ø160
19
Ø3
17.5 3
5.5
6 SW.24
176 190
176 196
6.5 10.5
U
Ø10
& -30+60 120 160 200 250 300 350 400 500
U 203 203 168 168 168 168 168 168 168
/
3m 5m
%DFN)ODQJH%RWWRP4XWOHW 'RXEOH&RQWDFW1U.
R1/2"
U
R1/2"
15
L
L
15
SW.24
61
93
31.5
100 51
Ø10
& -30+60 120 160 200 250 300 350 400 500
U 203 203 168 168 168 168 168 168 168
/
3m 5m
)URQW)ODQJH%RWWRP4XWOHW Weight:1780 gr
'RXEOH&RQWDFW1U.
Weight:1600 gr
TO ORDER 1U 6FDOH&RQWDFW7\SH&DSSLODU\OHQJ/4XDQWLW\
MBT / 06
SAM
CIRCULAR BI-METAL THERMOMETERS WITH ELECTRICAL CONTACT TYPES T R A N S F O R M E R
A C C E S S O R I E S
CONTACT DEVICES WITH ONE CONTACT Pointer moves clockwise
&RQWDFW7\SH and code
Switching function
Type
&RGH
&RQWDFWFORVHVLIYDOXHULVHVDERYHOLPLW
NA
PK 102
1&
PK 101
&RQWDFWDQGFRQWDFWFORVHLI value rises above limit
NANA
PK 122
&RQWDFWDQGFRQWDFWRSHQLIYDOXH rises above limit
1&1&
PK 111
&RQWDFWRSHQVFRQWDFWFORVHVLIYDOXHULVHV above limits
1&1$
PK 112
&RQWDFWFORVHVFRQWDFWRSHQVLIYDOXHULVHV above limits
1$1&
PK 134
Switching Characteristic
1. 2.
1 . Contact (red) 2 . Neutral (green)
&RQWDFWRSHQVLIYDOXHULVHVDERYHOLPLW 1. 2.
&RQWDFWUHG 2 . Neutral (green)
CONTACT DEVICES WITH TWO CONTACT
&RQWDFWUHG &RQWDFWEOXH 3 . Neutral (green)
&RQWDFWUHG &RQWDFWEOXH 3 . Neutral (green)
&RQWDFWUHG &RQWDFWEOXH 3 . Neutral (green)
&RQWDFWUHG &RQWDFWEOXH 3 . Neutral (green)
1.
2. 3.
1. 2. 3.
1. 2. 3.
1.
2. 3.
MBT / 07
SAM
CIRCULAR BI-METAL THERMOMETERS NOMINAL SIZE 65mm T R A N S F O R M E R
CONSTRUCTIVE SPECIFITIONS: Thermowell Connection : R 1/2". Zinc coated steel. (only 50mm. brass material) Heat sensor:%LPHWDO+HOLFDO6SULQJ6HQVRU Tube: Brass material, Case:6WHHO=LQF&RDWHG Front ring:&KURPHSODWHGVWHHO Window: Glass or acyrilic plastic.
A C C E S S O R I E S
MEASURING RANGE&& &&&& &&2WKHUPHDVXULQJ units can be printed on the dial, depending on the requirements. NOMINAL THERMOWELL LENGTHS: Shown in technical drawings.
TECHNICAL SPECIFICATIONS: Accuracy: 2.0 % F.S., (DIN 16203) Mounting: Thermowell is mounted to the place where it is going to measure temperature. Put the sensor tube into thermovil. When mounting do never screw it by holding from its case. Screw it by a spanner from the thermowell. Operating Range: Use 3/4 of full scale.Short time peaks up to the full scale.
Ø12
Ø9
R1/2"
SW 22
12
15
/
8
& -30 +60 120 160 200 250 300 350 400 500
65
/6WHP/HQJWK 50 x x -
%DFN&RQQHFWLRQ
100 150
200
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
250 300 x x x x x x x x x
Weight: 180gr
x x x x x x x x x
400
500
x x x x x x x x x
x x x x x x x x x
700 1000 x x x x x x x x x
x x x x x x x x x
Nr : 065402
TO ORDER 1U6FDOH6WHP/HQJKW/4XDQWLW\ MBT / 08
SAM
CIRCULAR BI-METAL THERMOMETERS NOMINAL SIZE 100mm T R A N S F O R M E R
&216758&7,9(63(&,),&$7,216 7KHUPRZHOO&RQQHFWLRQ5=LQFFRDWHGVWHHO +HDW6HQVRU%LPHWDO+HOLFDO6SULQJ Sensor Tube: Brass material. &DVH%RWWRPFRQQHFWLRQEODFNHQDPHOVWHHOEDFN connection Zn coated steel. Front Ring: Bottom connection bajonet black enamel steel, back connection chrome plated steel. Window: Glass or acyrilic plastic.
A C C E S S O R I E S
Operating Range: Use 3/4 of full scale, short time peaks up to the full scale 0($685,1(5$1*(&& && Other measururing units can be printed on the dial, depending on the requirements. 120,1$/7+(502(///(1*7+66KRZQLQWHFKQLFDO drawings.
TECHNICAL SPECIFICATIONS: Accuracy: 2.0 % F.S., (DIN 16203) Mounting: Thermowell is mounted to the place where it is going to measure temperature. Put the sensor tube into the thermovil. When mounting do never screw it by holding from its case. Screw it by a spanner from the thermowell.
51 13
11
Ø12
Ø100
SW24
Ø9
R1/2"
110
15 25
SW24
10
15
16,5
100
L
L
R1/2"
Ø9 Ø12
& -30+60 120 160 200 250 300 350 400 500
/6WHP/HQJWK 50
100
150
200
250
300
400
500
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
%RWWRP&RQQHFWLRQ
Weight: 430 gr
Nr: 100401
700 1000
-
-
& -30 +60 120 160 200 250 300 350 400 500
/6WHP/HQJWK 50
100
150
200
250
300
400
500
-
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
x x x x x x x x x
%DFN&RQQHFWLRQ
Weight: 300 gr
700 1000
x x x x x x x x x
x x x x x x x x x
Nr: 100402
TO ORDER 1U6FDOH6WHP/4XDQWLW\
MBT / 09
SAM
BI-METAL THERMOMETERS HOUSINGS T R A N S F O R M E R
A C C E S S O R I E S
AA 36 AA 22 AA 32
AA 30
120
x
205
3/4'' GF
1/2'' GM
1'' GM
150
3/4'' GF
Ø12
Ø10
F
A
Ø9
M
)5((%8/%
Ø12
PK %8/%:,7+32&.(7
;$'-867$%/(/(1*7+PP
0$7(5,$/6WDLQOHVV6WHHORU%UDVV