Transcript
Wall Thermostat SKU 99300650 Compatibility • • • •
• •
All Travis Gas Stoves 33 DVI Insert 31 DVI Insert 564 SS and DF
864 TRV, ST, and HO All Travis Pellet Stoves or Inserts
Packing List • • • •
Thermostat Thermostat Wire (20’) (2) Screws (for attaching thermostat) “Y” Jumper Wires (for gas appliances only)
Installation Warnings ! Shut off power to the appliance and allow it to cool prior to installation. ! This kit must be installed by a qualified technician. ! Do not connect 110 VAC to the gas control valve or on/off switch on gas heaters or the thermostat posts on pellet heaters. Follow the instructions on the following pages for the type of model being addressed.
Wire Connection - Pellet Heaters Attach the thermostat wire to the circuit board.
a
Open the hopper lid and remove the screw holding the right panel in place. Phillips Screwdriver Swing the panel open.
b c
If necessary, attach the pellet stove connector wires to the ends of the receiver wires.
Route the wires up to the circuit board and attach the quick-connects to the thermostat posts (orientation does not matter).
d Page 1 of 3
Bundle up any excess wire with a lock-tie to prevent it from contacting any hot or moving parts
9/3/10 - 17601040
© Travis Industries, Inc.
Wall Thermostat SKU 99300650 Wire Connection - Gas Heaters The included wire splitter allows the installer to connect the thermostat to the on/off switch on the heater. Follow the directions below to install the splitter in series or parallel connection. WARNING: Make sure all wiring is secure and does not contact hot or moving components. NOTE:
The newer switch has two terminals and is pictured below. Older switches have four terminals. Use the top and bottom terminal on either side of the switch when connecting the wires (see the illustration to the right).
Parallel Connection A parallel connection allows either the thermostat or on/off switch to turn the heater on. See table below: On/Off Switch ON On/Off Switch OFF Thermostat ON
Heater is ON
Heater is ON
Thermostat OFF
Heater is ON
Heater is OFF
To wire the heater in parallel, follow the directions below:
a
c
b
On / Off Switch
Thermostat Wires
Series Connection A series connection allows either the thermostat or on/off switch to turn the heater off. See table below: On/Off Switch OFF On/Off Switch ON Thermostat ON
Heater is ON
Heater is OFF
Thermostat OFF
Heater is OFF
Heater is OFF
To wire the heater in series, follow the directions below:
a
c
b
On / Off Switch
Thermostat Wires
Page 2 of 3
9/3/10 - 17601040
© Travis Industries, Inc.
Wall Thermostat SKU 99300650 Thermostat Placement and Installation 1
Determine a location for the thermostat that is within range of the 20' length of thermostat wire. It should be centralized in the room and away from the heater. The wire may be routed externally on the wall or behind the wall (preferred). Run the thermostat wire to this location. Use nylon ties, if necessary to keep the wire from contacting any hot portions of the heater.
2
Follow the directions below to attach the thermostat and thermostat wires. Pull the cover off the thermostat
50
60
70
80
90
50 60 70 80 90
Run the thermostat wires through the wall (cut off excess wire, leaving 6” of slack).
Robertshaw
Expose 1/2” of wire and attach to these two posts.
Standard Screwdriver
Attach the thermostat to the wall through these two holes.
Page 3 of 3
9/3/10 - 17601040
© Travis Industries, Inc.