THERMOSTATS
Thermostats
RTE 102/104
RTEV 102/104/102V
RTEV 302
RTEV 202/204
Electronic thermostats Setting of temperature on the RTE 102/104 is done on the circuit board under the housing to prevent unauthorised persons from changing the selected temperature. Thermostats are designed to control heat directly or to be used as sensors in larger centrally controlled facilities. RTEV 102/104 is equipped with a dial for setting the temperature. The setting range can be limited on the back of the dial and the thermostat can be calibrated there as well, if necessary. RTEV 102V is also equipped with an alternating relay and can therefore be used for the regulation of heating or cooling. External sensors mounted in ventilation ducts or the floor can also be connected.
Type
128
Voltage
RTEV 202/204 has a function switch for on/off connection as well as the optional connection of external sensors. A fixed temperature reduction of 4ºC can be activated by an externally connected contact, such as a weekly timer. The setting range can be limited and calibrated on the setting dial. RTEV 302 also has a built-in clock function in addition to the dial and the option of connecting external duct or floor sensors. The period for temperature reduction by 4ºC is 5, 7, 12, or 16 hours. The preferred period is set on the circuit board upon installation. The reduction period is activated by pushing the start button at the desired time of day. The clock is then set and the reduction period starts at that time every day automatically. An ongoing temperature reduction period can be interrupted with a push of the start button. The following day, the reduction period once again begins at the usual set time.
[V]
Max. current breakpoint [A]
Setting range
Protection class
HxWxD
[°C]
RTE102
230
15
+7 +35°C
IP30
71x71x28
RTE104
400
8
+7 +35°C
IP30
71x71x28
RTEV102
230
15
+7 +35°C
IP30
71x71x28
RTEV104
400
8
+7 +35°C
IP30
71x71x28
RTEV102V
230
15
+7 +35°C
IP30
71x71x28
RTEV202
230
15
+7 +35°C
IP30
71x71x28
RTEV204
400
8
+7 +35°C
IP30
71x71x28
RTEV302
230
15
+7 +35°C
IP30
71x71x28
[mm]
Frico AB, Box 102, SE-433 22 Partille Tel: +46 31-336 86 00 Fax: +46 31-26 28 60
[email protected] www.frico.se Design and specifications are subject to change without notice.
THERMOSTATS
KRT1900/1901
KRTV19 KRTE12
Capsulated Thermostats Capillary tube thermostats and electrical thermostats with alternating contacts Capillary tube thermostats with alternating contacts for the control of heaters and fans. The housing is of thermal plastic. Convertible between 230/400 V and approved for 16 A at 230 V and 10 A at 400 V. KRT 1900/1901 both have internal dials but have different setting ranges. KRTV 19 has an external dial with an adjustable stop for the maximum setting.
Type
Voltage [V]
KRT1900 KRT1901
Electronic thermostats are not subject to mechanical wear. Thus, they are very reliable and have longer durability. A sensor on a 3 metres long cable is included with the KRTE 12 thermostat. The sensor can be placed anywhere or fixed directly on the thermostat. The cable is easily extendable. The KRTE 12 has an alternating contact and is approved for 10A at 230V.
Setting range [°C]
Protection class
HxWxD [mm]
230/400
0 +40°C
IP55
165x57x60
230/400
-35 +10°C
IP55
165x57x60
KRTV19
230/400
0 +30°C
IP44
165x57x60
KRTE12
230
-40 +40°C
IP55
165x57x60
Frico AB, Box 102, SE-433 22 Partille Tel: +46 31-336 86 00 Fax: +46 31-26 28 60
[email protected] www.frico.se Design and specifications are subject to change without notice.
129
THERMOSTATS
KRT2800
40001
2-stage thermostats, capillary tube 2-stage regulation is appropriate for the soft and economical control of heating output in e.g. fan heaters and air curtains. There are two types to choose from: KRT 2800 with an adjustable temperature difference between the stages (1 - 4°C).
40001 with a fixed temperature difference (2°C) between the stages. Both are convertible between 230/400V and approved for 16A at 230V and 10A at 400V.
Type
Voltage [V]
Setting range [°C]
Protection class
HxWxD [mm]
KRT2800
230/400
0 +40°C
IP55
165x57x60
40001
230/400
0 +40°C
IP55
145x100x72
RTI2
2-stage thermostat, electronic 2-stage thermostat with internal setting. Adjustable temperature difference between the stages (110°C).
130
Type
Voltage [V]
Setting range [°C]
Protection class
HxWxD [mm]
RTI2
230/400
+5 +35°C
IP44
150x80x50
Frico AB, Box 102, SE-433 22 Partille Tel: +46 31-336 86 00 Fax: +46 31-26 28 60
[email protected] www.frico.se Design and specifications are subject to change without notice.
THERMOSTATS
WIRING DIAGRAMS THERMOSTATS Internal wiring diagrams (clock)
1 2 3 4 5
RTE 102
N 230V~ P
IP30
(clock)
1 2 3 4 5
L1 400V~ L2
IP30
RTE 104
Load max 15 A
RTE(V)102
RTE(V)104
Load max 8A
RTEV 102
RTEV 104 1 2 3 4 5 6
IP30
N 230V~ P Cool
(Ext. sensor)
RTEV 102V
Heat max 15 A
RTEV102V
(clock)
1 2 3 4 5
N 230V~ P
IP30 (Ext.
RTEV 202
sensor)
Load
RTEV202
max 15 A
RTEV 302
2 1
16 h
2 1
12 h
2 1
7h
2 1
5h
N
1 2 230V~ 4 5
P
IP30 2 1
Load max 15 A
RTEV302
Ext. sensor
1 2 3 4 5
(clock) L1 400V~ L2
IP30
RTEV 204
(Ext. sensor)
RTEV204
Load max 8A
Frico AB, Box 102, SE-433 22 Partille Tel: +46 31-336 86 00 Fax: +46 31-26 28 60
[email protected] www.frico.se Design and specifications are subject to change without notice.
131
THERMOSTATS
WIRING DIAGRAMS THERMOSTATS Internal wiring diagrams
KRT(V) 19(00) 16A 230V~ /10A 400V~
KRTE 12 10A 230V~ /6A 400V~
<ϑ
˚C
3 2 1
230V~
KRT1900
1 2 3 5 4
A B
KRTE12 PTC
N L1 L 2(N 2 )
L1 L (N)
KRTV19
40001 10A 230/ 400 V~
KRT 2800, 16A 230V~ /10A 400V~
˚C ˚C
3 2 1
3 2 1
KRT2800
1 2
-1– -4˚C 2
3 4
3
1
L1 L 2 (N)
L1 L (N)
RTI2 16A 230V~ /10A 400V~