Three-phase Energy Meter For Transformer Connection With S0 Pulse Output Main Features

   EMBED


Share

Transcript

Data sheet www.sbc-support.com Three-phase energy meter for transformer connection with S0 pulse output The S0 interface is a hardware interface for the transmission of measured values via pulses. Main features 3-phase energy meter, 3 × 230 / 400 VAC 50 Hz For CT measurement to 6000 A ■ Indication of instantaneous power, voltage and current ■ 7-digit display for 1 tariff ■ Lead seal possible with cap as accessory ■P  recision class B according to EN50470-3, Precision class 1 according to IEC62053-21 ■ S0 pulse output ■ ■ Order Number Standard Version: MID Version: High Current: Sealing caps: AWD3D5W10MC2A00 AWD3D5W10MC3A00 AWD3D5W10ND3A00 4 104 7485 0 Mounting Technical data Precision class B according to EN50470-3 1 according to IEC62053-21 Monting On 35 mm rail, according to EN60715TH35 Terminal connections main circuits Conductor cross-section 1.5 –16 mm2, screwdriver Pozidrive no. 1, slot no. 2, torque 1.5 –2 Nm Terminal connections control circuit Conductor cross-section max. 2.5 mm2, screwdriver Pozidrive no. 0, slot no. 2, torque 0.8 Nm Insulation characteristics 4 kV/50 Hz test according to VDE0435 Operating voltage 3 × 230 / 400 VAC, 50 Hz Tolerance –20% /+15% Power consumption Active 0.4 W per phase Counting range 000˙000.0 ... 999˙999.9 1˙000˙000 ... 9˙999˙999 Display LCD backlit, digits 6 mm high Display without mains power Capacitor based LCD max. 2 times over 10 days S0 output (interface) Optocoupler max. 30 V /20 mA and 5 V min. impedance 100 Ω, pulse width 30 ms Ambient temperature –25°…+55 °C Transmission distance, S0 output max.1000 m (at 30 V /20 mA) Storage temperature –30°…+85 °C Environment Mechanical M2 Electromagnetic E2 Relative humidity 75% without condensation 6 kV 1.2/50 µs surge voltage according to IEC255-4 Device protection class II EMC / Interference immunity Surge voltage according to IEC61000-4-5 at main circuit, 4 kV Surge voltage according to IEC61000-4-5 at pulse outputs S0, 1 kV Burst voltage according to IEC61000-4-4, 4 kV ESD according to IEC61000-4-2, contact 8 kV, air 15 kV CT measurement 5…1500 A 1000…6000 A Reference / maximum current Iref = 5 A, Imax = 6 A Iref = 5 A, Imax = 6 A Starting / minimum current Converter ratio Pulses per kWh Ist = 10 mA, Imin = 0.05 A  5 : 5  50 : 5 100 : 5  200 : 5  250 : 5  500 : 5  600 : 5  1250 : 5  1500 : 5 Ist = 10 mA, Imin = 0.05 A 150 : 5 1000 : 5 1250 : 5 1500 : 5 300 : 5 400 : 5 2000 : 5 2500 : 5 3000 : 5 750 : 5 1000 : 5 4000 : 5 5000 : 5 6000 : 5 LED 10 pulses / kWh 1 pulse / kWh S0 output 10 pulses / kWh 1 pulse / kWh Error indication Example: connection error at L3 CT Example: connection error at L1 and L3 CT Select Select Dimensioned drawings 70 70 62 62 57,7 57.7 31 31 22,7 22.7 CT 27 27 4.5 4,5 9 9 9 9 30,5 30.5 Select 45 8282 69.5 69,5 68 68 35 35 11 11 4.5 4,5 66 7 11,7 ==(58,5) 55xx11.7 [58.5] 6 Display elements, converter measurement CT 2 | www.sbc-support.com Select Indicates total consumption partial consumption This value can be reset ■ CT  Indicates the setting for the current transformer ratio ■ Select  When bridge Z1-Z2 is open, the transformer ratio can be adjusted under menu item: Select ■ P (kW) Indicates the instantaneous output per phase or for all phases ■ U (V) Indicates voltage per phase ■ I (A) Indicates current per phase ■ kWh Indicates the unit kWh for display of consumption ■ L1/L2/L3 Whenever the display shows P, U, I or Error, the corresponding phase will be indicated ■ Error When phase is absent or current direction is wrong. The corresponding phase will also be indicated. ■ T1 total ■ T1 part Indicates 3-phase energy meter AWD3 with S0-interface | Datasheet Menu to display the value on LCD Start T1total tota l T1part . CT Select P(kW ) U(V) Class B L1 L2 I(A) CT U(V) Class B L3 Error T1total tota l T1part . Select P(kW ) U(V) CT I(A) Select P(kW ) L1 L1 L2 L2 L3 Error Select P(kW ) L2 I(A) Class B L3 Error U(V) I(A) CT tota l T1part . T1total Select P(kW ) CT Error U(V) I(A) I(A) Select P(kW ) L1 L2 L3 Error U(V) I(A) 5 … 1500 A 150:5 500:5 1500:5 200:5 600:5 L1 AWD3D5W AWC3D5W Class B L3 CT U(V) Select P(kW ) L1 L2 L3 Error L2 Class B L3 Error U(V) T1total tota l T1part . I(A) CT AWD3D5W AWC3D5W tota l T1part . T1total Instan. Power (P) Select P(kW ) L2 T1total tota l T1part . Class B 100:5 400:5 1250:5 CT L1 Class B > 3 s AWD3D5W10MC_A00 5:5 50:5 250:5 300:5 750:5 1000:5 T1total tota l T1part . > 3 s AWD3D5W AWC3D5W Error CT L1 L3 T1total tota l T1part . Ratio Current Transformer (CT) T1total tota l T1part . Select P(kW ) AWD3D5W AWC3D5W Class B CT AWD3D5W AWC3D5W tota l T1part . T1total T1 partial (T1 part) I(A) AWD3D5W AWC3D5W U(V) AWD3D5W AWC3D5W L3 Error AWD3D5W AWC3D5W L2 Class B AWD3D5W AWC3D5W L1 T1 total Select P(kW ) L3 U(V) I(A) T1total tota l T1part . CT tota l T1part . T1total Select P(kW ) CT Select P(kW ) L1 L2 CT Voltage (U) Select P(kW ) L2 Class B L3 Error U(V) I(A) Class B Error U(V) I(A) L2 Class B L3 Error U(V) I(A) AWD3D5W AWC3D5W L1 L3 AWD3D5W AWC3D5W L1 tota l T1part . T1total AWD3D5W AWC3D5W L2 Error AWD3D5W AWC3D5W L1 Class B T1total tota l T1part . CT Select P(kW ) L2 tota l T1part . T1total CT Select P(kW ) L3 Error U(V) I(A) AWD3D5W AWC3D5W L1 Class B L2 Class B L3 Error U(V) I(A) AWD3D5W AWC3D5W L1 T1total tota l T1part . CT Select P(kW ) L2 CT U(V) T1total tota l T1part . Select P(kW ) I(A) CT Select P(kW ) L1 Current (I) Class B L3 Error U(V) I(A) L1 AWC3D5W AWD3D5W L2 L2 Class B L3 Error U(V) tota l T1part . T1total I(A) CT AWD3D5W AWC3D5W tota l T1part . T1total L3 Error AWD3D5W AWC3D5W L1 Class B Select P(kW ) L2 L3 Error U(V) T1 T1 part . T1 total tota l T1 I(A) CT CT AWD3D5W AWC3D5W L1 Class B P(kW ) Select P Select L2 L2 L3 L3 Error Error U(V) U(V) I(A) I(A ) AWD3D5 W AWC3D5W L1 L1 Class Class B B Start Datasheet | 3-phase energy meter AWD3 with S0-interface www.sbc-support.com | 3 Wiring diagram AWD3 with CT measurement S0 output totall T1part . T1tota CT 5 … 30 VDC The secondary, mains current transformer connection has to be connected to the phase to be measured and therefore the transformer don’t have to be grounded. (kW )) Select P(kW L2 L2 3 × 230/400 VAC Class B L3 L3 Error U(V) I(A) AWD3D5W AWC3D5W L1 L1 L1 L2 L3 N (PEN) 4 | www.sbc-support.com Fuse: T 250 mA (3x) 3-phase energy meter AWD3 with S0-interface | Datasheet Datasheet | 3-phase energy meter AWD3 with S0-interface www.sbc-support.com | 5 Saia-Burgess Controls AG Bahnhofstrasse 18 | 3280 Murten, Switzerland T +41 26 672 72 72 | F +41 26 672 74 99 www.saia-pcd.com [email protected] | www.sbc-support.com P+P26/496 EN05 10. 2013  Subject to change without notice.