Preview only show first 10 pages with watermark. For full document please download

×íñ ßóð ýßîü ×íñ ßóð óñüëôû

   EMBED


Share

Transcript

×ÍÑ ßÓÐ ÝßÎÜ ×ÍÑ ßÓÐ ÓÑÜËÔÛ Schulz-Electronic GmbH | Postfach 11 01 18 . D-76487 Baden-Baden . Hausanschrift | Dr.-Rudolf-Eberle-Str. 2 . 76534 Baden-Baden Fon +49.7223.9636.0 . Fax + 49.7223.9636.90 . [email protected] . www.schulz-electronic.de ISO AMP DELTA ELEKTRONIKA BV Installation CAUTION Electrostatic discharge (ESD) can damage components inside the power supply or ISO AMP CARD. Take the following precautions to prevent ESD: Remove all cables from the power supply, wear a grounded anti static wrist strap. Keep the ISO AMP CARD in its original ESD safe bag as long as possible. Installing the ISO AMP MODULE • Mount the ISO AMP MODULE using the wall or rail mounting adapter. • Connect the power supply to the ISO AMP MODULE with the supplied 15 pole cable. Connect a 15-30 V DC supply voltage to the 2-pole connector. + and - are indicated on the module. Finally connect your programming source to the connector marked ‘TO PROG. SOURCE’ • For use with other units than Delta Elektronika power supplies, make sure to connect pin 1 to pin 8 on the connector 'To Power Supply'. Front panel with connectors. To prog. source To supply Operating For remote programming and monitoring please refer to the power supplies’ manual. The warning that the Ø of the programming input (pin 1) is connected to the minus output is no longer valid when the ISO AMP is used. Configure and Calibrate The ISO AMP can be configured for both 5V and 10 V signal levels. Selecting a signal level is done by closing or opening DIP-jumpers. See fig. 1 - Lay-out for ISO AMP card PCB P510 on page 6 for the component layout of the ISO AMP. A closed jumper means 5V, an opened jumper means 10 V. The signal level for each of the four analog channels can be selected individually. See ESD precautions on this page. Signal Jumper Signal Trimmer (full scale) CVPROG J4, closed=5 V, open=10 V CVPROG R51 CCPROG J3, closed=5 V, open=10 V CCPROG R40 CVMON J2, closed=5 V, open=10 V CVMON R29 CCMON J1, closed=5 V, open=10 V CCMON R18 Table 1 2000 rev. February 2008 Table 2 DESCRIPTIONS Page 4 DELTA ELEKTRONIKA BV ISO AMP The full scale of the analog channels of the ISO AMP is factory calibrated within 0.1% for a 5 V signal level. Configuring jumper J1...J4 for 10 V signal levels without re-calibrating can introduce an extra full scale error of 0.1%. Table 2 shows the full scale calibration trimmers. See fig. 1 - Lay-out for ISO AMP card PCB P510 on page 6 for the component layout of the ISO AMP. Warning: before proceeding with the calibration of the ISO AMP make sure that your measuring equipment has the correct voltage and current rating. Voltage calibration • Connect a suitable, high accuracy volt meter to the output terminals of the power supply and put the CV programming switch on the power supply in the position ‘PROG’ • Apply 5.000 V or 10.000 V (depending on the jumper setting) to the CVPROG input. • Calibrate the output voltage of the power supply with R51. • Connect the volt meter to the CVMON connection and calibrate the CVMON signal with R29. Current calibration • Switch off the power supply, connect a suitable, high accuracy current meter across the output terminals of the power supply and put the CC programming switch on the power supply in the position ‘PROG’ • Apply 5.000 V or 10.000 V (depending on the jumper setting) to the CCPROG input. • Calibrate the output current of the power supply with R40. • Connect a volt meter to the CCMON connection and calibrate the CCMON signal with R18. WEEE (Waste Electrical & Electronic Equipment) Correct Disposal of this Product Applicable in the European Union. This marking shown on the product, its packing or its literature indicates that it should not be disposed with other wastes at the end of its working life, but should be collected separately to recycle it responsibly to promote the sustainable reuse of material resources. Page 5 CALIBRATION 2000 rev. February 2008 ISO AMP DELTA ELEKTRONIKA BV fig. 1 - Lay-out for ISO AMP card PCB P510 C1 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C2 C20 C21 C22 C23 C24 C25 C26 C27 C28 C29 C3 C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C4 C5 C6 C7 C8 C9 D1 D10 D11 D12 D13 D2 D3 D4 D5 D6 D7 D8 D9 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 10NF 50V 10NF 50V 10NF 50V 10NF 50V 1000PF 1000V 2200PF 250V 10NF 50V 47PF 100V 150PF 50V 47PF 100V 150PF 50V 10NF 50V 47PF 100V 47PF 100V 47PF 100V 47PF 100V 1UF16V 1UF16V 1UF16V 1UF16V X7R 0.47UF25V 1UF16V 10NF 50V 1UF16V 1UF16V 1UF16V 1UF16V 1UF16V 1UF16V 1UF16V 10NF 50V 1000PF 1000V 1000PF 1000V 10NF 50V 10NF 50V 10NF 50V 10NF 50V 10NF 50V 10NF 50V BZX84 C8V2 BZX84 C8V 2 BZG03-C15 BZG03-C15 BZX84C12V BZX84 C8V 2 BZX84 C8V 2 BZX84 C8V 2 BZX84 C8V 2 BZX84 C8V 2 BAS28 BAS28 BZX84 C8V 2 2000 rev. February 2008 PHILIPS PHILIPS PHILIPS PHILIPS CERAMIC CERAMIC PHILIPS YAGEO PHILIPS YAGEO PHILIPS PHILIPS YAGEO YAGEO YAGEO YAGEO PHILIPS PHILIPS PHILIPS PHILIPS AVX PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS CERAMIC CERAMIC PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS PHILIPS IC1 IC10 IC11 IC12 IC13 IC14 IC15 IC16 IC17 IC18 IC19 IC2 IC20 IC21 IC22 IC23 IC24 IC3 IC4 IC5 IC6 IC7 IC8 IC9 R1 R10 R11 R12 R13 R14 R15 R16 R17 R19 R2 R20 R21 R22 R23 R24 R25 R26 R27 R28 R3 R30 R31 R32 R33 R34 R35 R36 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = TCLT1002 VISHAY HCNR201 HP OP97FS AD OP97FS AD HCNR201 HP OP97FS AD OP97FS AD HCNR201 HP OP97FS AD OP97FS AD HCNR201 HP TCLT1002 VISHAY OP97FS AD C O N V TMA 2415 D T R A C O LM317LM N A T . S E M I C O N LT1236ACS8-5 LT TL064 TI TCLT1002 VISHAY TCLT1002 VISHAY TCLT1002 VISHAY TCLT1002 VISHAY 74HCU04 PHILIPS TCLT1002 VISHAY OP97FS AD 2.2K MF/.125/200 10K MF/.125/200 1.8K MF/.125/200 10 MF/.125/200 10 MF/.125/200 10 MF/.125/200 10 MF/.125/200 10 MF/.125/200 100 MF/.125/200 100K/0.1%/ 0.25W ROE 2.2K MF/.125/200 100K/0.1%/ 0.25W ROE 3.3M MF/.125/200 220K MF/.125/200 680 MF/.125/200 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 220K MF/.125/200 2.2K MF/.125/200 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 3.3M MF/.125/200 220K MF/.125/200 680 MF/.125/200 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE LAYOUT + COMPONENT LIST R37 R38 R39 R4 R41 R42 R43 R44 R45 R46 R47 R48 R49 R5 R50 R52 R53 R54 R55 R56 R57 R58 R59 R6 R60 R61 R62 R63 R64 R65 R66 R67 R68 R69 R7 R70 R71 R72 R73 R74 R75 R76 R77 R78 R79 R8 R80 R81 R82 R83 R84 R85 R9 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 220K MF/.125/200 2.2K MF/.125/200 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 3.3M MF/.125/200 220K MF/.125/200 680 MF/.125/200 220K MF/.125/200 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 2.2K MF/.125/200 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 3.3M MF/.125/200 220K MF/.125/200 680 MF/.125/200 220K MF/.125/200 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 10K MF/.125/200 100K/0.1%/ 0.25W ROE 100K/0.1%/ 0.25W ROE 220 MF/.125/200 680 MF/.125/200 8.2 MF/.125/200 100 MF/.125/200 100 MF/.125/200 100 MF/.125/200 27K MF/.125/200 27K MF/.125/200 10K MF/.125/200 27K MF/.125/200 27K MF/.125/200 2.2K MF/.125/200 10K MF/.125/200 10 MF/.125/200 1 MF/.125/200 100K/0.1%/ 0.25W ROE 2.74K/0,1% /0.25W ROE 14.7K/0.1% /0.25W ROE 10 MF/.125/200 10K MF/.125/200 5.6 MF/.125/200 10 MF/.125/200 10 MF/.125/200 1K MF/.125/200 1K MF/.125/200 1K MF/.125/200 10K MF/.125/200 Page 6