TL1006 |1800-1900 MHz 63W LinearPA DESCRIPTION This class A GaAs module is designed for both military and commercial applications. It is capable of supporting any signal type and modulation format, including but not limited to 3-4G telecom, WLAN, OFDM, DVB, and CW/AM/FM. The latest device technologies and design methods are employed to offer high power density, efficiency, and linearity in a small, lightweight package.
FEATURES Over / Under / Reverse Voltage Protection Reflected Power Measurement Temperature Output
Forward Power Measurement High Speed On/Off Control Optional Heatsink
Specifications subject to change without notice. Typical performance at +12VDC at +25oC in a 50Ω system
RF / ELECTRICAL PARAMETER Operating Frequency P1dB Power Output Gain Gain Flatness Linear Power Linear Power Test Conditions Input Return Loss Operating Voltage Current Draw Quiescent Current Draw Switching Time
MIN 1800 +47.0 46.0
-16 +11
TYP +48.0 47.0 1.0 +41.0 W-CDMA @ -55 dBc ACPR -18 14.0 15.0 1.0
MAX 1900
1.5
+13 15.0 2.0
UNIT MHz dBm dB dB dBm -dB VDC A A uS
Triad RF Systems Inc. | 180 Tices Lane, Building A, Suite 107, East Brunswick, NJ 08816 Tel: 1-(855) 558-1001 x1 |
[email protected] rev 07/15/14
TL1006 |1800-1900 MHz 63W LinearPA MECHANICAL PARAMETER Dimensions (L x W x H) RF Connectors (Input / Output) DC / Control Connector Cooling Mounting Weight Weight with heatsink
VALUE 6 x 3.5 x 0.693 SMA-F / SMA-F 7W2 Male Baseplate Conduction - Optional Heatsink Available 4-40 Thru Holes 14 24
UNIT in ----oz oz
FILL SPACE
ENVIRONMENTAL / PROTECTIONS PARAMETER Operating Temp. (Housing Temp.) Storage Temp Range Humidity Range Altitude Shock / Vibration Max RF Input Load VSWR @ P1dB PA Baseplate Shutoff Temperature
MIN -40 -60
MAX +85 +100
0-100 0-30,000 MIL-STD-810 and equivalents +4.0 Open / Short Output Protection +90
UNIT °C °C % ft. -dBm -°C
DC / CONTROL PINS PIN LABEL
NAME
DESCRIPTION
A1
GND
Ground
1 2 3 4 5 A2
TEMP Amp Enable NC GND NC +VDC
Temp Monitor: Temp in DegC = (Vout - 0.5V) / 10 TTL On/Off Low=Enable, High=Disable Not Connected Ground Not Connected Supply Voltage - Range Specified in Datasheet
Triad RF Systems Inc. | 180 Tices Lane, Building A, Suite 107, East Brunswick, NJ 08816 Tel: 1-(855) 558-1001 x1 |
[email protected] rev 07/15/14
A
B
C
D
E REVISIONS APPROVED DESCRIPTION DATE 08/15/2014 INITIAL RELEASE DMC
REV 0
1
1
.000
1.250
3.850
4.750
6.000
.000
.000
.125 J1
A2 - +VDC 1 - TEMP 2 - AMP ENABLE 3 - NC 4 - GND 5 - FWD A1 - GND
.853 2 J1
2
RF IN
RF OUT
2.250
RF IN
3.050
RF OUT
3.375 3
.000 .335
3
3.500
.150 THRU (x4) .335 .309 .000 .693 .335 .000
4
DRAWN
AHA
7/9/2014
DESIGNED
DMC
10/6/2013
CHECKED
BG
7/9/2014
180 TICES LANE BUILDING A, SUITE 107 EAST BRUNSWICK, NJ 08816 855-558-1001
4
ENG APPROVED
Housing Outline 107
MFG APPROVED
DIMENSIONS ARE IN INCHES UNLESS SPECIFIED OTHERWISE DECIMALS .XX .01 .XXX .005
A
B
C
TOLERANCES FRACTIONS 1/32
SIZE
DWG NO.
REV
A
0
ANGLES
SCALE: NONE
2
D
CAGE CODE
67DZ3
SHEET
E
1
OF
3
A
B
C
D
E
1
1
DETAIL A A
2
2
3
4
PIN FUNCTION TEMP 1 2 AMP ENABLE 3 NC 4 GND 5 FWD A1 GND A2 +VDC
CONNECTOR PINOUT NOTES Temp Monitor: Temp in DegC = (Vout - 0.5V) / 10 TTL On/Off Low=Enable, High=Disable Not Connected Ground Forward Power Measurement Ground Supply Voltage - Range Specified in Datasheet
3
4
NOTES: 1. P/N OF CONNECTOR ON AMPLIFIER: CONNEC 3007W2PCM99A10X 2. EXACT PINOUT MAY VARY WITH MODEL AND CUSTOMER SPECIFICATIONS
DRAWN
AHA
7/9/2014
DESIGNED
DMC
10/6/2013
CHECKED
BG
7/9/2014
ENG APPROVED
B
C
SIZE
DWG NO.
D
REV
A SCALE: NONE
MFG APPROVED
A
Housing Outline 107 0 CAGE CODE
67DZ3
SHEET
E
2
OF
3
A
B
C
D
E
1
1
2
2 MATE CABLE
3
3 3007W2SCM99A10X
NOTES: 1. P/N OF MATING CONNECTOR REQUIRED: CONNEC 3007W2SCM99A10X OR EQUIVALENT 2. P/N OF BACKSHELL/HOOD: EMERSON NETWORK POWER CON AIM - CAIMBRIDGE 40-9715H 4
4
3. TRIAD CABLE P/N: C12080301 4. WIRE DIAMETER: 24 AWG
DRAWN
AHA
7/9/2014
DESIGNED
---
6/4/2014
CHECKED
BG
7/9/2014
ENG APPROVED
B
C
SIZE
DWG NO.
D
REV
A SCALE: NONE
MFG APPROVED
A
Housing Outline 107 0 CAGE CODE
67DZ3
SHEET
E
3
OF
3