Preview only show first 10 pages with watermark. For full document please download

Tl1006 |1800-1900 Mhz 63w Linearpa

   EMBED


Share

Transcript

TL1006 |1800-1900 MHz 63W LinearPA DESCRIPTION This class A GaAs module is designed for both military and commercial applications. It is capable of supporting any signal type and modulation format, including but not limited to 3-4G telecom, WLAN, OFDM, DVB, and CW/AM/FM. The latest device technologies and design methods are employed to offer high power density, efficiency, and linearity in a small, lightweight package. FEATURES Over / Under / Reverse Voltage Protection Reflected Power Measurement Temperature Output Forward Power Measurement High Speed On/Off Control Optional Heatsink Specifications subject to change without notice. Typical performance at +12VDC at +25oC in a 50Ω system RF / ELECTRICAL PARAMETER Operating Frequency P1dB Power Output Gain Gain Flatness Linear Power Linear Power Test Conditions Input Return Loss Operating Voltage Current Draw Quiescent Current Draw Switching Time MIN 1800 +47.0 46.0 -16 +11 TYP +48.0 47.0 1.0 +41.0 W-CDMA @ -55 dBc ACPR -18 14.0 15.0 1.0 MAX 1900 1.5 +13 15.0 2.0 UNIT MHz dBm dB dB dBm -dB VDC A A uS Triad RF Systems Inc. | 180 Tices Lane, Building A, Suite 107, East Brunswick, NJ 08816 Tel: 1-(855) 558-1001 x1 | [email protected] rev 07/15/14 TL1006 |1800-1900 MHz 63W LinearPA MECHANICAL PARAMETER Dimensions (L x W x H) RF Connectors (Input / Output) DC / Control Connector Cooling Mounting Weight Weight with heatsink VALUE 6 x 3.5 x 0.693 SMA-F / SMA-F 7W2 Male Baseplate Conduction - Optional Heatsink Available 4-40 Thru Holes 14 24 UNIT in ----oz oz FILL SPACE ENVIRONMENTAL / PROTECTIONS PARAMETER Operating Temp. (Housing Temp.) Storage Temp Range Humidity Range Altitude Shock / Vibration Max RF Input Load VSWR @ P1dB PA Baseplate Shutoff Temperature MIN -40 -60 MAX +85 +100 0-100 0-30,000 MIL-STD-810 and equivalents +4.0 Open / Short Output Protection +90 UNIT °C °C % ft. -dBm -°C DC / CONTROL PINS PIN LABEL NAME DESCRIPTION A1 GND Ground 1 2 3 4 5 A2 TEMP Amp Enable NC GND NC +VDC Temp Monitor: Temp in DegC = (Vout - 0.5V) / 10 TTL On/Off Low=Enable, High=Disable Not Connected Ground Not Connected Supply Voltage - Range Specified in Datasheet Triad RF Systems Inc. | 180 Tices Lane, Building A, Suite 107, East Brunswick, NJ 08816 Tel: 1-(855) 558-1001 x1 | [email protected] rev 07/15/14 A B C D E REVISIONS APPROVED DESCRIPTION DATE 08/15/2014 INITIAL RELEASE DMC REV 0 1 1 .000 1.250 3.850 4.750 6.000 .000 .000 .125 J1 A2 - +VDC 1 - TEMP 2 - AMP ENABLE 3 - NC 4 - GND 5 - FWD A1 - GND .853 2 J1 2 RF IN RF OUT 2.250 RF IN 3.050 RF OUT 3.375 3 .000 .335 3 3.500 .150 THRU (x4) .335 .309 .000 .693 .335 .000 4 DRAWN AHA 7/9/2014 DESIGNED DMC 10/6/2013 CHECKED BG 7/9/2014 180 TICES LANE BUILDING A, SUITE 107 EAST BRUNSWICK, NJ 08816 855-558-1001 4 ENG APPROVED Housing Outline 107 MFG APPROVED DIMENSIONS ARE IN INCHES UNLESS SPECIFIED OTHERWISE DECIMALS .XX .01 .XXX .005 A B C TOLERANCES FRACTIONS 1/32 SIZE DWG NO. REV A 0 ANGLES SCALE: NONE 2 D CAGE CODE 67DZ3 SHEET E 1 OF 3 A B C D E 1 1 DETAIL A A 2 2 3 4 PIN FUNCTION TEMP 1 2 AMP ENABLE 3 NC 4 GND 5 FWD A1 GND A2 +VDC CONNECTOR PINOUT NOTES Temp Monitor: Temp in DegC = (Vout - 0.5V) / 10 TTL On/Off Low=Enable, High=Disable Not Connected Ground Forward Power Measurement Ground Supply Voltage - Range Specified in Datasheet 3 4 NOTES: 1. P/N OF CONNECTOR ON AMPLIFIER: CONNEC 3007W2PCM99A10X 2. EXACT PINOUT MAY VARY WITH MODEL AND CUSTOMER SPECIFICATIONS DRAWN AHA 7/9/2014 DESIGNED DMC 10/6/2013 CHECKED BG 7/9/2014 ENG APPROVED B C SIZE DWG NO. D REV A SCALE: NONE MFG APPROVED A Housing Outline 107 0 CAGE CODE 67DZ3 SHEET E 2 OF 3 A B C D E 1 1 2 2 MATE CABLE 3 3 3007W2SCM99A10X NOTES: 1. P/N OF MATING CONNECTOR REQUIRED: CONNEC 3007W2SCM99A10X OR EQUIVALENT 2. P/N OF BACKSHELL/HOOD: EMERSON NETWORK POWER CON AIM - CAIMBRIDGE 40-9715H 4 4 3. TRIAD CABLE P/N: C12080301 4. WIRE DIAMETER: 24 AWG DRAWN AHA 7/9/2014 DESIGNED --- 6/4/2014 CHECKED BG 7/9/2014 ENG APPROVED B C SIZE DWG NO. D REV A SCALE: NONE MFG APPROVED A Housing Outline 107 0 CAGE CODE 67DZ3 SHEET E 3 OF 3