Preview only show first 10 pages with watermark. For full document please download

Tlp-97311/a/sm - Lithium Batteries

   EMBED


Share

Transcript

MODEL TLP-97311/A/SM Ordering: P/N 61973111600 Termination: Pressure Contacts TECHNICAL DATA (Typical values @+25ºC for batteries stored for one year or less) Capacity to 3.0V (@250mA @1% duty cycle) 1.65 Ah Nominal voltage 3.6 V Maximum 1 second pulse to 3.0V 1A Maximum pulse length @125mA to 2.8V 1000 sec Delay time to 3.0V @125mA No Delay Weight 35 gr Operating temperature range -40ºC to +85ºC Capacity retention after 10 years 85% Volts • • • • VOLTAGE VS. PULSE DURATION HIGH ENERGY UP TO 1A PULSE CAPABILITY INSTANT VOLTAGE RESPONSE NO PASSIVATION EFFECT 100 mA 3.6 250 mA 500 mA 3.5 3.4 3.3 Diameter (max.) – 16.5 mm Length (max.) – 58 mm 3.2 3.1 3.0 2.9 2.8 0.001 0.01 0.1 1 10 100 1000 10000 Pulse Duration [sec] Min. Voltage vs. Temp. for 1 sec Pulse Max. Pulse Width to Min. Voltage of 2.8V 3.6 Pulse Amplitude [A] 3.4 Voltage [V] 3.2 3.0 2.8 2.6 100 mA 2.4 2.2 200 mA 300 mA 2.0 -60 -40 -20 0 20 40 60 80 Temperature [ºC] 1.1 1.0 0.9 0.8 0.7 -20ºC 0.6 0.5 0.4 -40ºC 0.3 0.2 0.1 0.0 0.01 0ºC 0.1 +25ºC 1 +85ºC 10 100 1000 Pulse Duration [sec] For High Pulse Current Applications Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 6100625 Rev. D June/07 Page 1 of 2 MODEL TLP-97311/A/SM The TECHNICAL battery is designed DATA specifically for applications requiring low background (Typical valueswith @+25ºC for batteries stored one Plus™ year orbattery less) combines currents combined high current pulses. The for Pulses the inherent benefits of bobbin type Lithium Thionyl Chloride cell with a novel hermetically sealed Hybrid Layer Capacitor (HLC). The addition of the HLC enhances the performance of the Lithium Thionyl Chloride cell to meet large pulse current requirements, thus providing greater performance and safety in comparison to jellyroll construction (spirally wound) type batteries. * The PTC is optional and not necessary in many cases. Volts DISCHARGE CHARACTERISTICS @ +25ºC 4.0 3.5 3.0 2.5 2.0 100 KΩ 180 KΩ 6.8 KΩ 18 KΩ ~0.5 mA ~0.2 mA ~36 μA ~20 μA (1.65 Ah) (1.61 Ah) (1.48 Ah) (1.44 Ah) 1.1 KΩ ~3 mA (1.0 Ah) 1.5 1.0 1 10 100 1000 10000 [Ah] Self Discharge vs. Temperature 18.0 Annual Capacity Loss [%] 100000 Hours Capacity vs. Current 1.7 16.0 Maximum 14.0 -30°C 1.5 0°C 25°C 12.0 Typical 10.0 1.3 8.0 50°C 72°C 6.0 1.1 4.0 2.0 0.0 20 40 60 80 Temperature [ºC] 0.9 0.01 0.1 1 Current [mA] For High Pulse Current Applications Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 6100625 Rev. D June/07 Page 2 of 2