Preview only show first 10 pages with watermark. For full document please download

Tm-mcpa - Pacific-wave

   EMBED


Share

Transcript

TM-MCPA For Cost Effective Coverage Extension or Capacity Upgrade August, 2006 Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com Contents ‰ TM-MCPA Overview ‰ Electrical Specifications ‰ Mechanical Overview ‰ Application - 2 Carriers BTS ‰ Application - 4 Carriers BTS ‰ Application - 8 Carrier BTS ‰ NMS Features Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com TM-MCPA Overview Due to rapid changes in wireless network environment, network operators are now faced with various infrastructure solutions and cost issues in upgrading wireless network. HFR’s MCPA product line (Tower-Mounted and Ground-Mounted) provides cost effective network coverage extension and capacity upgrade solution. Apart from obvious coverage extension, sharing of existing RF cable and antenna when introducing new service channel for capacity or service upgrade is the major advantage of this system. BTS Tower TMMCPA BTS Cell TM GSM/GPRS/EDGE MCPA – Advantages TM-MCPA Cell • Increase channel count per antenna while maintaining power level per channel BTS • Increases coverage area for new cell designs • Avoid coverage reduction when increasing number of channels in existing systems MS Rx [dBm] TM-MCPA Signal Power Existing BTS Signal Power • Tower-Mount Feature to maximize output power at the Antenna TM GSM/GPRS/EDGE MCPA - Management TM-MCPA can be easily monitored and controlled using built-in microprocessor. Following extensive features are included for managing system easily. -85dBm • User selectable downlink/uplink RF gain Distance • Parameter monitoring and alarm reporting • Easy setup & maintenance feature Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com Electrical Specifications Parameters Unit Specifications Forward MHz 935 ~ 960 Reverse MHz 890 ~ 915 Channel 1~8 Channels GSM and EDGE System Forward dBm 50dBm (100W) / Total 6 Carrier = 42 dBm / Carrier Reverse dBm -10 dBm (0.1mW) / Total Forward dB 20 ± 1 Reverse dB 12 ± 1 Forward dB 25 / 0.5 Reverse dB 15 / 1.0 Noise Figure dB < 2.5 Bypass Insertion Loss dB < 1.5 Tx - Rx dBc > 70 Rx - Tx dBc > 70 Forward dBc < – 60 (typical) Maximum Tx Input Power without Damage dBm +46 Normal Input Power Range for Rx dBm -105 ~ -55 dB < 1.0 Frequency Range Number of Carriers Maximum Output Power Gain Gain Control Range / Step Cut-off Frequency Intermodulation (IMD) Gain Flatness Forward / Reverse Fail Safe Operation Forward / Reverse Power Supply NMS Remarks Reverse Diversity: 12 dB (± 1dB) At Fail Safe Operation Mode At 2 Carrier, Max. Output Power Peak to Peak RF Bypass VAC 220V± 20% Instead -48VDC SMS Modem Include External Alarm Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com Mechanical Overview Parameters Specifications Remarks Environment Application IP 55 Water proof Type In/Out RF Connectors DIN Type Female Coupling Port SMA Type Female External Alarm Port D-SUB 9pin (Female) Dimension (W x D x H) 370 x 690 x 422 mm Weight 53 Kg Mounting Type Wall or Tower Mount Operating Temperature -20 ~ +50 ℃ Storage Temperature -30 ~ + 80 ℃ Operating Humidity 5 ~ 90 % Non- Condensing Storage Humidity 0 ~95 % Non - Condensing Input / Output TM – MCPA Picture Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com Application - 2 Carrier BTS Benefits Service Configuration without TM-MCPA Tx0/Rx0 Antenna Service Configuration with TM-MCPA ™ Tx Power : 40 dBm Ö 47 dBm / Carrier ™ BTS Sensitivity : -108 dBm Ö -111 dBm Rx1 Diversity Antenna Tx/Rx0 Antenna Tx1/Rx1 Antenna • Tx Power before Antenna = 40 dBm/Carrier • Tx Power before Antenna = 47 dBm/Carrier TM-MCPA Install TM-MCPA • Cable Loss : 3 dB (100m) assumed • No. of Cables and Antennas : 2 • Cable Loss : 3 dB (100m) assumed • No. of Cables and Antennas : 2 Duplexer Duplexer Duplexer Duplexer • HPA Output Power • HPA Output Power = 45 dBm/Carrier = 45 dBm/Carrier • BTS Output Power • BTS Output Power = 43 dBm/Carrier = 43 dBm/Carrier • BTS Sensitivity LNA1 • BTS Sensitivity = -108 dBm HPA1 HPA2 BTS LNA1 LNA2 HPA1 HPA2 BTS Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com LNA2 = -111 dBm Application - 4 Carrier BTS (Case 1) Benefits Service Configuration without TM-MCPA Tx0/Rx0 Antenna Tx1/Rx1 Antenna ™ Tx Power : 40 dBm Ö 44 dBm / Carrier ™ BTS Sensitivity : -108 dBm Ö -111 dBm ™ No need for additional antenna installation when increasing no. of carriers from 2 to 4 Tx2/Rx2 Antenna Service Configuration with TM-MCPA Rx1 Diversity Antenna Tx/Rx0 Antenna Tx3/Rx3 Antenna • Tx Power before Antenna = 44 dBm/Carrier • Tx Power before Antenna = 40 dBm/Carrier TM-MCPA Install TM-MCPA • Cable Loss : 3 dB (100m) assumed • No. of Cables and Antennas : 2 • Cable Loss : 3 dB (100m) assumed • No. of Cables and Antennas : 4 Duplexer Combiner Combiner Duplexer Duplexer Duplexer Duplexer Duplexer Duplexer Duplexer • HPA Output Power • HPA Output Power = 45 dBm/Carrier = 45 dBm/Carrier • BTS Output Power • BTS Output Power = 43 dBm/Carrier • BTS Sensitivity = 40 dBm/Carrier HPA1 HPA2 HPA3 HPA1 HPA4 HPA2 HPA3 HPA4 • BTS Sensitivity LNA1 LNA2 LNA3 LNA4 LNA1 LNA2 LNA4 = -111 dBm = -108 dBm BTS LNA3 BTS Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com Application - 4 Carrier BTS (Case 2) Benefits Service Configuration with TM-MCPA ™ Tx Power : 37 dBm Ö 44 dBm / Carrier ™ BTS Sensitivity : -105 dBm Ö -111 dBm ™ Avoid coverage reduction when increasing no. of carriers from 2 to 4 Service Configuration without TM-MCPA Tx1/Rx1 Antenna Tx0/Rx0 Antenna Rx1 Diversity Antenna Tx/Rx0 Antenna • Tx Power before Antenna = 44 dBm/Carrier • Tx Power before Antenna = 37 dBm/Carrier TM-MCPA Install TM-MCPA • Cable Loss : 3 dB (100m) assumed • No. of Cables and Antennas : 2 • Cable Loss : 3 dB (100m) assumed • No. of Cables and Antennas : 2 Duplexer Duplexer Duplexer Combiner Combiner Combiner Combiner Duplexer Duplexer Duplexer Duplexer Duplexer • HPA Output Power • HPA Output Power = 45 dBm/Carrier = 45 dBm/Carrier • BTS Output Power • BTS Output Power = 40 dBm/Carrier • BTS Sensitivity = 40 dBm/Carrier HPA1 HPA2 HPA3 HPA1 HPA4 HPA2 HPA3 HPA4 • BTS Sensitivity LNA1 LNA2 LNA3 LNA4 LNA1 LNA2 LNA4 = -111 dBm = -105 dBm BTS LNA3 BTS Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com Application - 6 Carrier BTS (Case 1) Benefits ™ Tx Power : 40 dBm Ö 42 dBm / Carrier ™ BTS Sensitivity : -108 dBm Ö -111 dBm ™ Avoid coverage reduction when increasing no. of carriers from 2 or 4 to 6. Service Configuration without TM-MCPA Tx1/Rx1 Antenna Tx2/Rx2 Antenna Rx1 Diversity Antenna Tx/Rx0 Antenna Tx5/Rx5 Antenna Tx0/Rx0 Antenna Service Configuration with TM-MCPA • Tx Power before Antenna = 42 dBm/Carrier Tx4/Rx4 Antenna Tx3/Rx3 Antenna • Tx Power before Antenna = 40 dBm/Carrier TM-MCPA Install TM-MCPA • Cable Loss : 3 dB (100m) assumed • No. of Cables and Antennas : 2 • Cable Loss : 3 dB (100m) assumed • No. of Cables and Antennas : 6 Combiner Duplexer Duplexer • HPA Output Power • HPA Output Power = 45 dBm/Carrier = 45 dBm/Carrier • BTS Output Power • BTS Output Power = 38 dBm/Carrier = 43 dBm/Carrier • BTS Sensitivity • BTS Sensitivity LNA1 = -108 dBm HPA1 LNA2 HPA2 LNA3 HPA3 LNA4 HPA4 BTS LNA5 HPA5 LNA6 HPA6 LNA1 HPA1 LNA2 HPA2 LNA3 HPA3 LNA4 HPA4 BTS Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com LNA5 HPA5 LNA6 HPA6 = -111 dBm Application - 6 Carrier BTS (Case 2) Benefits ™ Tx Power : 35 dBm Ö 42 dBm / Carrier ™ BTS Sensitivity : -107 dBm Ö -111 dBm ™ No need for additional antenna installation ™ Avoid coverage reduction Service Configuration without TM-MCPA Tx0/Rx0 Antenna Service Configuration with TM-MCPA Rx1 Diversity Antenna Tx/Rx0 Antenna Tx1/Rx1 Antenna • Tx Power before Antenna = 42 dBm/Carrier • Tx Power before Antenna = 35 dBm/Carrier TM-MCPA Install TM-MCPA • Cable Loss : 3 dB (100m) assumed • Cable Loss : 3 dB (100m) assumed • No. of Cables and Antennas : 2 • No. of Cables and Antennas : 2 Combiner Combiner • HPA Output Power Duplexer Duplexer • HPA Output Power = 45 dBm/Carrier = 45 dBm/Carrier • BTS Output Power • BTS Output Power = 38 dBm/Carrier = 38 dBm/Carrier • BTS Sensitivity = -103 dBm • BTS Sensitivity LNA1 HPA1 LNA2 HPA2 LNA3 HPA3 LNA4 HPA4 BTS LNA5 HPA5 LNA6 HPA6 LNA1 HPA1 LNA2 HPA2 LNA3 HPA3 LNA4 HPA4 BTS Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com LNA5 HPA5 LNA6 HPA6 = -111 dBm NMS Features GSM Modem TM-MCPA 1 Air Interface Interface Board GSM Modem Processor . . . . . . . . . . . . . . TM-MCPA N Computer GSM Modem equipped in NMS Center and TM-MCPA sends SMS via air interface for 1:1 communication. In order to control or monitor each TM-MCPA from NMS Center, simply add repeater phone number into dialogue window provided in emulator program. GSM Modem (NMSCenter) Thru NMS configuration allows operator to monitor and control alarms and parameters in NMS Center. Personal computer in NMS Center shall be installed with Emulation Program for accessing each TM-MCPA. Processor This NMS will be advantageous when managing both repeaters and MCPAs using one NMS screen. NMS Major Features ƒ Alarm Reporting to NMS Center ƒ Alarm Reporting to A/S Phone ƒ Monitor / Control ƒ Alarm History with Excel Format ƒ MCPA & Repeater Registration NMS Configuration Antenna Port DC Adaptor Port Communication Port SIM Card Holder NMS Modem Box NMS Modem Box Components Product Enquiry & Local support contact [email protected] Another related component can be found at www.pacificwave-wireless.com