Preview only show first 10 pages with watermark. For full document please download

Tmt190b Datasheet

   EMBED


Share

Transcript

TMT 190B eHART head transmitter Universal head transmitter for resistance thermometers (RTD), thermocouples (TC), e Application areas resistance, voltage transmitters, for installation in a sensor head (Form B) Performance Temperature head transmitter for converting various input signals into a scalable 4 to 20 mA analogue output signal 2 wire technology, 4 to 20mA analogue output Thermocouple (TC) Expanded resistance input (max 2K ) Input Resistance thermometer (RTD) Resistance transmitter ( ) Voltage transmitter (mV) High accuracy in total ambient temperature range An internal temperature sensor for active temperature compensation(For T/C) Wide voltage supply range Expanded voltage input (max 2KmV) Technical data Power supply Supply voltage Output Output signal Signal on alarm 7.5 to 45 VDC(without display) , polarity protected 4 to 20 m A Underranging Linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break; sensor open-circuit 3.6 mA Load Linearisation/transmission behaviour max.(V power supply-7.5 V)/0.022 A Installation instructions Installation area:Connection head accord. To DIN 43 729 Form B; TAF 10 �ield housing Installation conditions Temperature linear, resistance linear, voltage linear Installation angle:no limit www.srcsl.com Page 2 / 5 Data sheet TMT190B Input Input Measurement ranges Type Pt100 -200 -200 Pt500 Resistance thermometer(RTD) Resistance transmitter -200 Pt1000 Cu50 Cu100 *Ni1000 Resistance( ) Connection type:2-,3- or 4-wiere connection B(PtRh30-PtRh6) Thermocouples(TC) on request -60 to 150 (-76 oF to 302oF) to 150 to 180 to 180 0 to 40 0 0 to 2000 o T(Cu-CuNi) Millivolt transmitter(mV) 10K 10K 10K (-58 F to 302 F) o 10K o (-76 F to 356 F) (-76 oF to 356oF) 0 to 1820 ( - 32 to 3308oF) 10K 10K 10 20 500K o -270 to 1300 (-454 to 2372oF) R(PtRh13-Pt) 10K o N(NiCrSi-NiSi) K(NiCr-Ni) Performance characteristics Response time (-58 oF to 302oF) -270 to 1000 (-454 to 1832 F) J(Fe-CuNi) 10K to 250 (-328 oF to 482oF) E(NiCr-CuNi) S(PtRh10-Pt) Voltage transmitters(mV) to 850 (-328 F to 1562 F) to 250 (-328 oF to 482oF) to 150 -60 -60 *Ni500 o -50 -50 *Ni100 Min.meas.Ranges o 50K -210 to 1200 (-346 to 2192oF) 50K -270 to 1372 (-454 to 2501oF) 50K 50K -50 to 1768 ( -58 to 3214.4 oF) 500K o -50 to 1768 (-58 to 3214.4 F) 500K -270 to 400 (-454 to 752oF) 50K -10 to 75mV 5mV -100 to 2000mV 20mV -100 to 100mV 5mV 6mV -100 to 500mV 1s Reference operating conditions Calibration temperature: 23 (73.4 oF) 5K Long term stability Switch on delay In�luence of ambient Load influence Power supply in�luence Self stability con�iguration Filter con�igurating Resolution 0.05%/year 5s Negligible Negligible Negligible 0 to 2% 0 to 160 0.3 Input RTD Maximum measured error A TC mV A Type Pt100, Ni100 Pt500, Ni500 Pt1000, Ni1000 Cu50 Cu100 K, J, T, E N S, B, R 0 to 40 0 0 to 2000 -10 to 75mV -100 to 100mV -100 to 500mV -100 to 2000mV Measurement accuracy 0.2K or 0.08% 0.5K or 0.20% 0.3K or 0.12% 0.2K or 0.08% 0.3K or 0.12% typ.0.5K or 0.08% typ.1.0K or 0.08% typ.2.0K or 0.08% 0.1 1.5 or 0.08% or 0.12% 20 V or 0.08% 0 V or 0.08% 0 V or 0.08% 0 V or 0.08% www.srcsl.com Page 3 / 5 Data sheet TMT190B Environment conditions Ambient temperature limits Storage temperature Condensation Degree of protection Shock and vibration resistance -40 to 85 (-40 -40 to 100 (-40 to 185 ) to 212 ) Allowable IP 00,IP66(installed) 4g/2 to 150 Hz as per IEC 60 068-26 Electromagnetic compatibility(EMC) Interference immunity and interference emission according to GB/T17626.2-1998), compliance with IEC 61000-4-3:1995. Dimensions Weight Dia. 44 mmX24 mm Approx. 34g Explosion Others Material Intrinsically safe: Exia II CT4 Housing: PC Potting: epoxy Electrical connections - + mA 7.5 to 45VDC 4 to 20 mA 2-wire 3-wire 4-wire Dimensions www.srcsl.com Page 4 / 5 Data sheet TMT190B How to programme 4 Transmitter with eHART -protocol - 3 + 250 + 7.5...45 VDC (Supply) - HART Modem 1 2 Standard HART Modem USB Interface PC Installation diagram www.srcsl.com Page 5 / 5 Data sheet TMT190B Ordering code Certi�ication A B Version for non hazardous areas NEPSI Ex ia CT4 Configuration transmitter connection A 1 2 3 4 TMT190B Standard factory con�iguration 3-wire Con�iguration connection TC Con�iguration connection RTD(2-wire) Con�iguration connection RTD(3-wire) Con�iguration connection RTD(4-wire) Con�iguration temperature sensor A 1 2 3 4 5 6 7 8 B E J K N R S T Standard factory con�iguration Pt100 Pt100 -200 to 850 (-328 oF to 1562oF) Pt500 -200 to 250 (-328 oF to 482oF) Pt500 -200 to 250 (-328 oF to 482oF) Pt1000 -200 to 250 (-328 oF to 482oF) Cu50 -50 to 150 (-58 oF to 302oF) Cu100 -50 to 150 (-58 oF to 302oF) Ni100 -60 to 180 (-76 oF to 356oF) Ni500 -60 to 180 (-76 oF to 356oF) Type B 0 to 1820 (-32 to 3308oF) Type E -270 to 1000 (-454 to 1832oF) Type J -210 to 1200 (-346 to 2192oF) Type K -270 to 1372 (-454 to 2501oF) Type N -270 to 1300 (-454 to 2372oF) Type R -50 to 1768 ( -58 to 3214.4 oF) Type S -50 to 1768 ( -58 to 3214.4 oF) Type T -270 to 400 (-454 to 752oF) Con�iguration A B C D Standard factory con�iguration ( Pt100/3-wire/0 to 100 ) Customised measurement range Customised expanded cor�iguration for TC ( see questionnaire ) Customised expanded cor�iguration for RTD ( see questionnaire ) Order code ( complete ) For example:TMT190B-AAAA CALIDAD EMPRESA CERTIFICADA ISO 9001 EC-6605/11 ACREDITADO POR ENAC