TNA820A10 TRISECTOR PENTA-BAND 1x 790-960 MHz, 2x 1710-2170 MHz, 2x 2300-2600 MHz
Compact Antenna Diameter 635 mm External RET available
Electrical specifications* Frequency Range (MHz)
R1
B1, B2
Y1, Y2
790—960
1710-2170
2300-2690
Polarization Gain (dBi)
±45º 17
Electrical Tilt (continuously adjustable)
17
18
2—10
Horizontal Beamwidth (º), -3dB
65,2
56,9
60,2
Vertical Beamwidth (º), -3dB
7,2
6,5
6,1
Front to Back Ratio (dB) 180º±30º total power
B2
>25
Cross Polar Discrimination (dB) Boresight
>19
>23
>17
Sidelobe suppresssion (dB) First sidelobe above horizon
17
17
16
Typ 20
Typ 20
Typ 22
First null fill (dB) Impedance (W) VSWR
50 < 1.5:1
Intraband isolation (dB)
> 30
Interband isolation (dB)
> 30
Intermodulation IM3 (dBc) Max power per input (W) External RET
Y2
< -150 300
B1
Y1
R1
AISG 2.0 / 3GPP Protocol
*All specifications are subject to change without notice. Refer to TELNET for the most current informa-
Mechanical specifications Input Position Dimensions (mm), H x Ø
30 x 7/16 female connectors Bottom, 3 x 10 (7/16) 2700 + 300 x 450
Weight (Kg)
110
Max wind speed (Km/h)
200
Azimuth (Full antenna / Per Sector)
1 of 2
± 50º / ± 0º
www.telnet‐ri.es
V150505
TNA820A10 Materials Radome End Caps Screws and nuts
Fiber glass + polyester Stainless Steel Stainless Steel
Environmental and mechanical tests IEC 60068-2-1: Cold
IEC 60068-2-32: Free Fall Test
IEC 60068-2-2: Dry heat
IEC 60068-2-56: Damp Heat Steady State
IEC 60068-2-6: Sine Vibration
IEC 60068-2-64: Random Vibration
IEC 60068-2-14: Change of Temperature
IEC 60529: IP Code Test
IEC 60068-2-18: Water (Handheld shower)
IEC 60695-2-1/2: Resistance to fire
IEC 60068-2-27: Shock Test
UNE-EN 60598-2-3: Resistance to wind
IEC 60068-2-29: Bump Test
Particular Specification: Resistance to ice
IEC 60068-2-30: Damp Heat Cyclic Environmental RET test Temperature Humidity Saline Fog IP specification
2 of 2
–33º C a 70º C 50º C, 98HR IEC68-2-52, severity 2 IP66, IEC 60529 (Feb 2001)
www.telnet‐ri.es
V150505