Preview only show first 10 pages with watermark. For full document please download

Toa | Rs-442 | Manual | Switch Board Rs-442 Installation Manual

   EMBED


Share

Transcript

INSTALLATION MANUAL SWITCH BOARD RS-442 Thank you for purchasing TOA’s Switch Board. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment. 1. GENERAL DESCRIPTION The RS-442 is a Switch board to be connected to the N-8400RS 4-wire system Substation Interface Unit. It is equipped with 1 microphone input (with a microphone unit), 3 switch inputs for call buttons, and 1 speaker output, enabling you to make a switch panel suitable for applications. By assigning a different master station as a calling destination to each Call button, you can call one of them and make a conversation. 2. CONNECTION Note Cut out unused wires to avoid short-circuiting. N-8400RS Substation interface unit To handset (refer to the following figure) (Red) 4P removable terminal plug (supplied with the N-8400RS) (Black) - To line 1 (Brown) To line 2 (Red) 8 Ω speaker output Microphone To line 3 (Orange) To line 4 (Yellow) Control output * (Green) (White) RS-442 (Gray) (Blue) (White) (Black) Two pairs of twisted pair cable + (Brown) Diode Frame ground Relay - + External power supply (White) 24 V DC (Blue) Switch input for the call button 3 (momentary) Switch input for the call button 2 (momentary) Switch input for the call button 1 (momentary) GND *Open collector output: 24 V DC, Max. 30 mA [RS-442 and RS-481 connections] Handset cables Wall surface Note When using the RS-481 Option handset, cut the jumper wire next to the handset joint cables on the circuit board as illustrated below. If not cut, sound comes out from the RS-442's speaker and returns back to the handset’s microphone, resulting in acoustic feedback. RS-442 (Bottom) RS-481 Handset joint cables RS-442 Jumper wire Handset joint cables 3. INSTALLATION 3.1. Installation Completion Drawing Unit: mm [Front] [Side] [Rear] 130 – 150 91.2 88.1 130 – 150 28.1 67.5 3.2. When Making Operation Panel for Flush-Mount Installation Put the RS-442 in the YC-302 2-Gang Electrical Box mounted in the wall. Then, connect the cables from RS-442 to the switches mounted on the operation panel separately prepared. Wall surface RS-442 YC-302 2-Gang Electrical Box (option) Tip YC-822 Indoor Wall-Mount Box can also be used. Operation panel (separately prepared) Note: When using the PA paging function, keep the operation panel as far away from the PA paging speaker as possible to avoid acoustic feedback. 4. SPECIFICATIONS Call Button Wiring Rated Input Control Output Microphone Wiring Transmission Range Operating Temperature Weight 6 cables (for 3 momentary switches) 1W Open collector, Maximum controlled voltage: 30 V DC Control current: 30 mA Electret condenser microphone Twisted pair cables (2 pairs) 1 km/ø0.5 mm (AWG24) 1.5 km/ø0.65 mm (AWG22) 2 km/ø0.9 mm (AWG19) 0 to 40 ºC 140 g Note: The design and specifications are subject to change without notice for improvement. Traceability Information for Europe Manufacturer: Authorized representative: TOA Corporation TOA Electronics Europe GmbH 7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo, Japan Suederstrasse 282, 20537 Hamburg, Germany URL: http://www.toa.jp/ 133-21-00014-00