Preview only show first 10 pages with watermark. For full document please download

Tools And Accessories For Utilities, A.b. Chance Hotline Tools

   EMBED


Share

Transcript

presents A.B. CHANCE Hot Line Tools Call Toll Free 1-877-GO ALTEC 9002-00027 09/05 Hot Line Tools Clampsticks and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p 3 Wire Holding Stick. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p 5 Trouble Shooter Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p 5 Elbow Puller Tools and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . .p 6 Insulated Wrenches and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 7 Universal Tool Kits .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 8 Telescopic Measuring and Disconnect Sticks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 8 Disconnect and Universal Sticks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 11 Universal Poles and Tool Hanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p 13 Hot Stick Care and Storage Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p 14 Rubber Insulating Blankets & Line Hoses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . .p 16 Covers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 17 Grounding Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .. . . . .p 18 Copper Mechanical Jumper Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .p 18 C-Type Grounding Clamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . .. . . .p 19 C-Type Clamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . .p 20 Grounding Clamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . .p 21 Ferrules & Jumper Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p 22 Grounding & Mechanical Jumper Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p 23 Call Toll Free 1-877-GO ALTEC 2 Clampsticks and Accessories Single-Piece Style Hinged Style The most versatile tool in a lineworker’s hands, the Chance Grip-All stick puts an easy-to-control “finger” on an insulated pole. Although primarily designed for installing hot-line and grounding clamps, it serves both overhead and underground circuits with various end fittings. Ideal for troubleshooters with limited tool-storage space in their vehicle, this folding version operates with the same features as the one-piece style. Commonly called a “shotgun,” the operating mechanism incorporates a sliding hand grip that opens the hook to grasp a clamp eyescrew and retract it into the tool head. A thumb latch then must be depressed to release the locked hand grip so it can open the hook. P/N 9000-30296 9000-30297 9000-30298 9000-30299 9000-30342 9000-30343 Folded 3’ 4” 4’ 4” 5’ 4” 6’ 4” 7’ 4” 8’ 4” Extended 1 1/4” x 6’ 7” 1 1/4” x 8’ 6” 1 1/4” x 10’ 6” 1 1/4” x 12’ 6” 1 1/4” x 14’ 6” 1 1/4” x 16’ 6” Weight 8 lb./3.6 kg. 9 lb./4.1 kg. 10 lb./4.5 kg. 10 1/2 lb./4.7 kg. 11 lb./5.0 kg. 11 1/2 lb./5.2 kg. While the tool head is of Lexan® for close-quarter operations, the worker must maintain recommended working distance solely on the Epoxiglas® pole section of the handles as the hook and its actuator are metal parts. Easy to care for, Grip-All sticks do not require field stripping to clean. All insulated parts including the operating rod are outside the main pole, readily accessible to wipe dry. CAUTION: Do not clean the plastic head with solvent. P/N 0704-20132 9000-40302 9000-30293 9000-30294 9000-30295 Description 1 1/4” x 4’ 5” 1 1/4” x 6’ 5 1/2” 1 1/4” x 8’ 5 1/2” 1 1/4” x 10’ 5 1/2” 1 1/4” x 12’ 5 1/2” Weight 5 3/4 lb./2.6 kg. 6 1/2 lb./2.9 kg. 7 1/4 lb./3.3 kg. 8 lb./3.6 kg. 8 3/4 lb./3.9 kg. P/N 9000-01868 To convert any Grip-All stick to use all Universal Tool Accessories, the P/N 9000-01868 adapter secures in the clampstick hook and head housing. Grip-All Clampstick Assist Ring Grip-All Extensions The Chance assist ring provides a suspension midpoint for any Grip-All stick. Particularly helpful on longer sticks, the assembly permits a support line to attach at the smaller ring. To help maintain safe-working clearances for hotline procedures, an insulated Strain Link Stick of proper size should be used in the handline. These extensions simply clamp on to the head of a Chance Grip-All clampstick, adding 4 to 6 feet of reach, and operates by using the controls on the Grip-All handle. P/N 9000-30377 9000-30378 Dimensions 1 1/4” x 4’ 1 1/4” x 6’ Weight 3 1/2 lb./1.6 kg. 4 lb./1.8 kg. P/N 9000-32543 3 1/2 lb./1.6 kg. 3 Clampsticks and Accessories Cont. Telescoping Style Positive Grip Clampstick Chance Telescoping Grip-All sticks can replace several conventional clampsticks. With fewer sticks, it still permits linemen to serve their many safe working distances and positioning needs. This can reduce the number of clampsticks required on a line truck, saving limited storage space. The Chance Epoxiglas® Positive Grip Clampstick is made for use on eyescrew grounding on tap clamps. It can be mounted on the line and tightened at angles up to 30°. Fittings are aluminum and bronze. The butt end of the tool is equipped with a combination tool hanger and universal head. Engineered interface between sections ensure that tool retracts with full control. Close fit also helps keep out dirt and moisture. Top section is of foam-center Epoxiglas® insulated pole. To install clamp, align locking ring with slot in housing; place eye of clamp into housing. Holding locking ring and clamp in one hand, rotate pole clockwise to trap eye. To remove clamp, engage locking ring on clamp body and rotate pole counter-clockwise to trap eye. Basic clampstick functions of this telescoping stye are identical to the fixed-length style. All controls can be manipulated while wearing gloves. Easy to disassemble, the Telescoping Grip-All stick must be kept clean and dry inside and out for maximum personnel protection. P/N 9000-31025 9000-31026 Extended Lengths 5’ 6 3/4”, 6’ 9 1/2”, 8’ 8’ 6 3/4”, 10’ 4 3/4”, 12’ 2 3/4”, 14’ Retracted Length 5’ 2 3/4” 8’ 3 3/4” P/N 9000-30302 9000-21303 9000-30422 9000-30425 Retracted Length 5’ 2 3/4” 8’ 3 3/4” Weight 6 lb./2.7 kg. 8 lb./3.6 kg. Call Toll Free 1-877-GO ALTEC 4 Regular Head Only Extra Long Head Only Extra long head for use with long eyescrew ground clamps. Telescoping Style with Universal Fitting on Handle Extended Lengths 5’ 6 3/4”, 6’ 9 1/2”, 8’ 8’ 6 3/4”, 10’ 4 3/4”, 12’ 2 3/4”, 14’ Head Type Regular Extra Long Weight 6 lb./2.7 kg. 8 lb./3.6 kg. Available in two sizes, each readily locks at variable lengths. The design features a rotating coupler and an engineered positive-lock button with safety stop to keep the sections from parting or the hook releasing while in use. The mechanism locks the sections into a solid and rattle-free tool. P/N 9000-33060 9000-33061 Dimensions 1 1/4” x 8’ 6” 1 1/4” x 8’ 6” Weight 4 lb./1.8 kg. 4 lb./1.8 kg. 1 lb./0.45 kg. 1 1/8 lb./0.5 kg. Wire-Holding Stick The Chance Epoxiglas® Wire-Holding Stick is used on or around energized lines for forming, bending and positioning jumper wires; and for holding conductors during splicing operations. The gripper, with an eye so that other sticks can assist with heavy bending, will handle No. 6 solid copper through 1590 kcmil ACSR. Operation of the wire-holding stick has been simplified so that it grips much like a vise-grip. By tightening the knurled nut at the control lever, the wire holding jaws can be positioned to grip the conductor firmly. When this is done, the tightening control lever must be relaxed in a position about one inch away from the pole. Then, to secure the grip on the conductors simply move the control lever all the way up along the rod. The head of the tool locks in three stop positions so that the lineman can engage and position conductors easily from most angles. The knurled screw handle below the jaw opening is used to adjust the head position from straight to right or left. P/N 9000-30368 9000-30369 Dimensions Weight 1 1/4” x 6’ 5” 6 1/2 lb./2.7 kg. 1 1/4” x 8’ 5” 6 3/4 lb./3.0 kg. Trouble Shooter Kit This Chance multi-duty kit includes six 4-foot sections of field-proven 1 1/4” Epoxiglas® Universal Pole that snap together. Spring-loaded locking buttons permit uses at 4, 8, 12, 16, 20 and 24-foot lengths. Butt section has a Plastisol end cap. Fitting on top section with thumbscrew accepts the Universal Accessories included in the kit. The kit includes the following: • Aluminum Disconnect Head for opening and closing switches, opening enclosed cutouts, etc. has built in hanger hook. • Non-Metallic Disconnect Head provides additional insulation for indoor substations where buswork and switches are in close proximity. Plastisol cap at top; 19” overall length with 15” long Epoxiglas® section. • Clamp Stick Head for use with 6” lone eyescrew ground clamps has locking ring with detent ball for on-off operation. Made from aluminum alloy. • Tree Trimmer adds 1 1/2 feet to reach with 3-to-1 mechanical advantage pulley and 25 feet of furnished rope. Offset universal fitting on trimmer accepts pruning saw. • Pruning Saw with deep-notched teeth for quick pullouts attaches direct to top pole, tree trimer or pistol grip. • Pistol Grip Saw Handle is for use when limbs can be reached and insulation is not needed. Made from aluminum alloy. • Storage Case of yellow heavy-duty vinyl-impregnated fabric has separate pockets for individual tools and Velcro flap closures. P/N 9000-31612 9000-32046 9000-32062 9000-44559 9000-31614 9000-44552 9000-21064 9000-44556 9000-44566 9000-32996 Description Complete Kit Top Section Epoxiglas® Pole Mid Section Epoxiglas® Pole Aluminum Disconnect Head Non-Metallic Disconnect Head Clamp Stick Head Tree Trimmer Pruning Saw Pistol Grip Saw Handle Storage Case Weight 24 lb./10.8 kg. 2.25 lb./1.0 kg. 2.25 lb./1.0 kg. 1/8 lb./0.06 kg. 1.25 lb./0.6 kg. 1.25 lb./0.6 kg. 3.5 lb./1.6 kg. .75 lb./0.3 kg. .50 lb./0.2 kg. 3.25 lb./1.5 kg. 5 Elbow Puller Tools and Accessories Impact Elbow-Puller Arc Snuffer Removal & Replacement Tools This lightweight Chance tool employs a simple, slidehammer mechanism to easily disengage and assist in replacing elbows. The tool and grippers help the operator control the elbow and stiff underground cable lead. Without de-energizing URD bushings, these two Chance hot-line tools permit easy retrieval of broken arc snuffers and installation of replacements. For a balanced grip the 5-pound slide hammer is Plastisol coated and flared at both ends. Also for secure handling, both front and rear handgrip areas of the pole are coated with Griptread, a grit-filled rubber-base paint. Available in three lengths, the tools are made of 1 1/4” diameter orange Epoxiglas® pole. The 6 and 8 foot units meet OSHA requirements with 25 and 48 inches of insulation respectively from the tool end to the handguard. On the 4 1/2 foot unit (labeled “For Rubber Glove Use Only”) insulation length measures 5 inches. To pull an elbow connector insert hook through eye on elbow. Close down grippers on elbow by rotating pole. Support tool with one hand on front grip behind handguard and other hand on slide hammer. Slam hammer from front to rear anvil. Resulting impact should release elbow with sufficient momentum to withdraw it from the bushing without extended arcing. To replace an elbow connector follow the same procedures for pulling except use slide hammer impact against front anvil to help seat the elbow. Designed to ensure adequate electrical clearances, both tools are to be used expressly in a Grip All clampstick. Intergal ring on each tool retracts into clampstick. Tool bodies are high-impact plastic with steel inserts. The removal tool works on the principle of a bolt extractor. Inserted into a damaged arc snuffer, it permits retrieval by unscrewing the broken part. The replacement tool controls alignment with a spring-action center post that snaps into the arc snuffer bore. Two steel lugs of the tool engage holes in the snuffer collar to transmit tightening torque. P/N 9000-30236 9000-30237 Description Removal Tool Replacement Tool Weight 1/4 lb./0.1 kg. 1/4 lb./0.1 kg. Elbow Connector Tool Grippers These Chance tools provide a sure grip for installing and disconnecting elbow terminators. The tool grabs the elbow and has a special integral hook that fits through the rubber eye of an elbow or the metal hook of a bushing cap so that the lineman has complete, positive control, overcoming the resistance of the stiff underground cable. P/N 9000-31822 9000-31850 9000-31851 Description 6 - foot length 8 - foot length 4 1/2 - foot length Weight 12 lb./5.4 kg. 12 1/4 lb./5.6 kg. 11 1/2 lb./5.2 kg. P/N 9000-30704 9000-30613 9000-30614 9000-30814 9000-30815 Description 15 kV Plastic-Coated 25 kV Plastic-Coated 25 kV Uncoated 34.5 kV Plastic-Coated* 34.5 kV Plastic-Coated** Weight 5/8 lb./0.3 kg. 1 lb./0.5 kg. 5/8 lb./0.3 kg. 1 lb./0.5 kg. 2 1/4 lb./1.0 kg. * Fits RTE 200 AMP and 600 AMP Elastimold “T” Elbow ** For Elastimold Elbows Call Toll Free 1-877-GO ALTEC 6 Insulated Wrenches and Accessories Flexible Insulated Wrenches Flexible Insulated Wrenches - Heavy Duty These wrenches are used for tightening nuts on hardware fittings on high-voltage lines. The coil spring around the universal joint has just the proper degree of flexibility so that the operator has control over the socket at various angles. The spring is easily removed for lubricating. Wrenches are made to fit any 1/2-inch square-shank socket. Chance sockets are deep throated and accurately broached. All wrenches are mounted on 1 1/2” diameter Epoxiglas® poles. Standard square socket in lower end accepts 1/2” squareshank ratchet or similar hand tools. Square shank on upper end fits any 1/2”-drive socket. Mounted on 1 1/2”-diameter Epoxiglas® extensions, these wrenches may be used for tightening nuts on hardware fittings on high-voltage lines. Coil spring around the universal joint limits flexibility so operator maintains control over the socket at various angles. Spring removes easily for lubrication. P/N 9000-66780 P/N 9000-32137 P/N 9000-32136 75 ft.-lb. torque rating 75 ft.-lb. torque rating 6’ 3” length 8’ 3” length Epoxiglas® Torque Extension Stick P/N 9000-18912 P/N 9000-18915 P/N 9000-18912 P/N 9000-18913 P/N 9000-18915 P/N 9000-18916 P/N 9000-18917 P/N 9000-18918 P/N 9000-66780 Insulated extension stick permits hot line work with hydraulic power tools on bucket trucks. Its 7/16”-hexagonal quick connect fitting couples with a power tool’s drive socket. On the other end, its square detent-ball fitting accepts all 1/2”-drive wrenches. The 1 1/4” x 4’ Epoxiglas® pole handguard is 6 inches from the ferrule with hex fitting. P/N 9000-18917 w/flexible 1/2” sq. plug and fixed 1/2” sq. plug w/flexible 1/2” sq. plug and fixed 1/2” sq. plug w/flexible 1/2” sq. plug and universal head hole through ferrule for a 5/8” turning rod w/flexible 1/2” sq. plug and universal head hole through ferrule for a 5/8” turning rod w/flexible 1/2” sq. plug and ratchet wrench with 1/2” sq. reversible plug w/flexible 1/2” sq. plug and ratchet wrench with 1/2” sq. reversible plug Ratchet Wrench 6’ 3” length 8’ 3” length 6’ 3” length P/N 9000-33009 Hex Socket Sets 8’ 3” length Available in SAE and Metric size, each set includes sockets to fit and 1/2” (12.17 mm) square-shank drive tool. 6’ 3” length 8’ 3” length P/N 9000-31085 includes 11 deep-well 6-point sockets in sizes from 1/2” through 1 1/8” P/N 9000-31086 includes 10 deep-well 6-point sockets in sizes from 10 mm through 19 mm 7 Universal Tool Kits With over 75 individual Chance Universal Tools to select for various maintenance jobs, these kits are a convenient way of ordering. With one catalog number shipped in a single carton, these tools are most frequently used by hot stick crews. Although all Universal Tools are still available as individual part numbers, ordering one or more of the following kits will cover most tool requirements. Tool Kit for Clevis Type Insulators Tool Kit for Ball Socket Insulators This 10-piece kit contains the Universal Tools normally used to handle cotter keys, bolts and insulator hardware for insulator control on Clevis-tongue type suspension or dead-end insulator strings. This 7-piece kit contains those Universal Tools required to handle cotter keys, bolts and hardware on ball and socket type suspension or dead-end insulator. Kit includes: • Pin Holder • Cotter Key Remover • Locating Pin • Cotter Key Installing Tool • Clear Vision Mirror Kit includes: • Shepherd Hook • Insulator Fork • Cotter Key Tool • Universal Adapter • All Angle Pliers • Cotter Key Remover • Cotter Key Pusher • Ball Socket Adjuster P/N 9000-31112 • Insulator Fork • Ball Socket Cotter Key P/N 9000-31113 Telescoping Measuring and Disconnect Sticks Telescoping Measuring/Disconnect Sticks Certified to OSHA dialectric requirements (Sub-part V, section 1926.951), these full-function Chance telescoping tools do more than separate measuring sticks and disconnect tools. To measure pole heights and conductor clearances from the ground, three lengths and English or Metric scales are available. Disconnect head supplied for operating switches and cutouts is removable. End fitting on insulated top section accepts other Universal Tool accessories for various tasks near energized conductors. The measuring scales are easy-to-read, with figures silk-screened on orange fiberglass sections. English scales are marked with each 1-foot increment designated in a box, each inch in bold numbers and half-inches designated by intermediate bars. Metric scales similarly display meters, decimeters and centimeters. A positive spring-loaded locking-button mechanism and safety plug feature in each section prevent separation of the tool. Once snapped into place, the buttons securely lock into position. There’s no worry about an unexpected tool retraction. English Scales (Feet, inches, half inches) Storage/Extended P/N Sections Lengths 9000-40310 7 61 in./30 ft. 9000-22013 8 63 in./35 ft. 9000-31735 8 48 in./25 ft. Weight 8 3/4 lb./3.9 kg. 11 lb./5.0 kg. 9 lb./4.1 kg. Metric Scales (Meters, decimeters, centimeters) Storage/Extended P/N Sections Lengths Weight 9000-40312 7 1.56 m/9.09 m. 8 3/4 lb./3.9 kg. 9000-22014 8 1.62 m/10.6 m. 11 lb./5.0 kg. Call Toll Free 1-877-GO ALTEC 8 Telescoping Measuring and Disconnect Sticks Cont. Telescoping Disconnect Tools These Chance Epoxiglas® Telescoping Tools have maximum convenience for the lineman because they permit him to perform many routine jobs from ground level. The universal end fitting on the insulated top section accepts a wide variety of attachments so the lineman can disconnect switches, replace cutout tubes and reclose, remove pole covers, prune trees, replace bulbs and complete many other overhead tasks. The sticks retract to approximately 5’ so that they can be carried on most trouble trucks, often in the cab section. They have heavy duty, spring-loaded plastic buttons that keep the extended tool sections securely locked in position. As each section is extended and twisted slightly, the buttons pop into place, allowing working to be done with complete control and confidence. These sticks are offered in standard and heavy duty. Both units use the same telescoping tube design. The tip section of the heavy duty units is slightly larger in diameter (1 1/4” versus 1 1/16”) so that each telescoping tube is slightly larger, resulting in a more rigid tool when fully extended, important where additional weight may be frequently encountered on maintenance tasks. Both tip sections employ time-proved Epoxiglas®, the unicellular foam-core material where the epoxy reinforced fiberglass wall is built around the foam core to prevent any moisture trapping voids that could build up between foam and tool. Standard Duty (1 1/16” dia. tip) P/N 9000-31023 9000-31017 9000-31018 9000-31019 9000-31020 9000-31021 9000-31022 Retracted Extended Lengths Length 8 ft. 56” 8 - 12 ft. 57” 12 - 16 ft. 59” 12 1/2 - 16 1/2 - 20 ft. 61” 16 1/2 - 20 1/2 - 25 ft. 63” 17 1/2 - 21 1/2 - 25 1/2 - 30 ft. 65” 22 - 26 - 30 1/2 - 35 ft. 67” Base Dia. 1 1/4” 1 1/2” 1 11/16” 1 7/8” 2 1/16” 2 1/4” 2 1/2” Sections 2 3 4 5 6 7 8 Weight 2 lb./0.9 kg. 2 3/4 lb./1.2 kg. 4 lb./1.8 kg. 5 1/4 lb./2.4 kg. 7 lb./3.2 kg. 8 3/4 lb./3.9 kg. 11 lb./5 kg. Retracted Length 26” 48” 40” Base Dia. 1 7/8” 2 1/2” 1 11/16” Sections 5 8 5 Weight 2 3/4 lb./1.2 kg. 9 lb./4.1 kg. 2 3/4 lb./1.2 kg. Retracted Extended Lengths Length 8 ft. 56” 8 - 12 ft. 57” 12 - 16 ft. 59” 12 1/2 - 16 1/2 - 20 ft. 61” 16 1/2 - 20 1/2 - 25 ft. 63” 17 1/2 - 21 1/2 - 25 1/2 - 30 ft. 65” Base Dia. 1 1/2” 1 11/16” 1 7/8” 2 1/16” 2 1/4” 2 1/2” Sections 2 3 4 5 6 7 Weight 3 lb./1.4 kg. 3 3/4 lb./1.7 kg. 5 lb./2.3 kg. 6 1/2 lb./2.9 kg. 8 1/2 lb./3.7 kg. 10 1/4 lb./4.6 kg. Compact Standard Duty (1 1/16” dia. tip) P/N 9000-32205 9000-31739 9000-33350 Extended Lengths 8 ft. 14 - 17 - 20 - 23 ft. 12 ft. Heavy Duty (1 1/4” dia. tip) P/N 9000-31597 9000-31598 9000-31599 9000-31600 9000-31601 9000-31602 Heavy Duty Standard Duty 9 Telescoping Measuring and Disconnect Sticks Cont. Heavy-Duty Adjustable Sticks Clearly marked at each 1-ft. extension lock, one of these Chance tools can replace as many as eight single-length hotsticks. Especially for such tight confines as substations, these adjustable sticks can be stored in standardlength canisters and avoid the difficulties of working extra-long sticks through busswork structures. Switch-Style Head These sticks are classified as heavy-duty due to their large (1 1/4” diameter) insulated top section and 1 1/2” O.D. epoxy-reinforced fiberglass base tube. In each size, a 2-foot section of the Epoxiglas® foam-core top section remains inside the base section at the longest locked, usable length. Also at the shortest locked length, the insulated top section extends a full 2 feet beyond the base. High-strength-plastic buttons keep these tools locked at each length. As the top section is extended and twisted, the lock button pops into place. For one worker to quickly adjust the length, a convenient alignment dot at 1-ft. setting on the insulated section matches another dot at the top of the base section. Disconnect-Style Head Disconnect-Style NEMA Head: P/N Lockable Lengths 9000-32600 10, 11, 12, 13, 14 ft. 9000-32601 12, 13, 14, 15, 16, 17, 18 ft. Collapsed 8’ 2 3/4” 10’ 2 3/4” Weight 6 1/2 lb./2.9 kg. 8 lb./3.6 kg. Collapsed 8’ 2” 10’ 2” Weight 6 1/2 lb./2.9 kg. 8 lb./3.6 kg. Collapsed 8’ 3 3/4” 10’ 3 3/4” Weight 6 1/2 lb./2.9 kg. 8 lb./3.6 kg. Switch-Style NEMA Head: P/N Lockable Lengths 9000-32602 10, 11, 12, 13, 14 ft. 9000-32603 12, 13, 14, 15, 16, 17, 18 ft. Extension length is clearly marked at each hole for button engagement. Universal Fitting Style: P/N Lockable Lengths 9000-32604 10, 11, 12, 13, 14 ft. 9000-32605 12, 13, 14, 15, 16, 17, 18 ft. Universal disconnect head (P/N 9000-44559) must be ordered as a separate item for universal-fitting style sticks. Call Toll Free 1-877-GO ALTEC 10 Disconnect and Universal Sticks Disconnect Sticks Chance disconnect sticks provide insulation safety for linemen in opening and closing disconnect switches and cutouts. They are also used for installing and removing open-link fuse links. Switch Stick Head Style Poles are made of Epoxiglas® and NEMA-standard heads of cast bronze in three types: switch head, disconnect head, or spliced disconnect head. For convenience in transporting and/or where greater length is required, spliced disconnect sticks are available. The splice is strong and rigid, easy to put together and easy to take apart. The taking-down feature of these sticks makes them especially handy to carry on line trucks or in tool trailers. Also available is the fiberglass head disconnect stick, which gives the additional insulation required for work where bus and disconnect switch spacings are confined, as in indoor substations. 1 1/4” Switch Stick Head Splice for Spliced Disconnect Style Switch Head P/N 9000-03046 9000-30461 9000-30462 9000-30463 9000-30464 9000-30467 Description Head Only 1 1/4” x 4’ 1 1/4” x 6’ 1 1/4” x 8’ 1 1/4” x 10’ 1 1/4” x 12’ Weight 4 oz./0.11 kg. 1 1/4 lb./0.6 kg. 1 1/2 lb./0.7 kg. 2 1/4 lb./1.0 kg. 2 3/4 lb./1.2 kg. 3 5/8 lb./1.6 kg. Description Head Only 1 1/2” x 6’ 1” 1 1/2” x 8’ 1” 1 1/2” x 10’ 1” 1 1/2” x 12’ 1” 1 1/2” x 16’ 1” 1 1/2” x 18’ 1” 1 1/2” x 20’ 1” Weight 5 oz./0.14 kg. 2 1/4 lb./1.0 kg. 2 13/16 lb./1.3 kg. 3 7/16 lb./1.5 kg. 4 lb./1.8 kg. 5 5/16 lb./2.4 kg. 6 lb./2.7 kg. 6 9/16 lb./3 kg. Disconnect Head 1 1/2” Disconnect Head P/N 9000-26403 9000-22403 9000-32403 9000-42640 9000-30465 9000-30466 9000-30468 9000-06403 Spliced Disconnect Head 1 1/4” Spliced Disconnect Head P/N 9000-21641 9000-61641 9000-81641 9000-02641 9000-42641 Description 1 1/4” x 6’ & 1 1/2” x 6’ 1” 1 1/4” x 8’ & 1 1/2” x 8’ 1” 1 1/4” x 8’ & 1 1/2” x 10’ 1” 1 1/4” x 10’ & 1 1/2” x 10’ 1” 1 1/4” x 12’ & 1 1/2” x 12’ 1” Weight 6 lb./2.7 kg. 7 1/2 lb./3.4 kg. 8 1/4 lb./3.7 kg. 9 lb./4 kg. 10 1/2 lb./4.7 kg. Fiberglass Head Fiberglass Head P/N 9000-56403 9000-66403 9000-76403 9000-86403 9000-96403 Description 1 1/4” x 4’ 1 1/4” x 6’ 1 1/4” x 8’ 1 1/4” x 10’ 1 1/4” x 12’ Weight 1 1/8 lb./0.5 kg. 1 5/8 lb./0.7 kg. 2 1/8 lb./1.0 kg. 2 5/8 lb./1.2 kg. 4 lb./1.8 kg. 11 Disconnect and Universal Sticks Cont. Sectional Disconnect and Universal Tools These Chance non-conductive splices snap together for just the right job length. Compact fittings interchange on safety-orange Epoxiglas® insulated sections, and store in limited space. For quick assembly and long life, metal buttons are rounded and springs are of stainless steel. Silicone coating and gloss finish seal out moisture. Base cap included with top sections. Extension Sections (Both Sizes: 4’, 6’, 8’ and 10’ lengths, wtih female fitting at top and male fitting at bottom) Tree Trimmer Standard Switch Head Disconnect Non-Metallic Disconnect Plastic Universal 1 1/4”-Diameter Poles Standard Switch Head Disconnect P/N Description 9000-32073 6 inches 9000-32053 4 feet 9000-32054 6 feet 9000-32055 8 feet Weight 3/4 lb./0.34 kg. 2 3/8 lb./1.07 kg. 2 5/8 lb./1.18 kg. 2 7/8 lb./1.29 kg. Non-Metallic Disconnect Head P/N Description 9000-32095 6 inches 9000-32059 4 feet 9000-40320 6 feet 9000-32061 8 feet Weight 1 lb./0.45 kg. 2 1/4 lb./1.01 kg. 2 1/2 lb./1.13 kg. 2 3/4 lb./1.22 kg. Plastic Universal Head P/N Description 9000-32071 6 inches 9000-32046 4 feet 9000-32047 6 feet 9000-32048 8 feet Weight 5/8 lb./0.28 kg. 2 lb./0.90 kg. 2 1/4 lb./1.01 kg. 2 1/2 lb./1.13 kg. Tree Trimmer Head P/N Description Weight 9000-32096 *2 feet 3 1/4 lb./1.46 kg. 9000-32097 *4 feet 3 1/2 lb./1.57 kg. *Length excludes trimmer head fitting Extension Section P/N 9000-32062 9000-32063 9000-32064 9000-32133 Description 4 feet 6 feet 8 feet 10 feet Weight 2 lb./0.90 kg. 2 1/4 lb./1.01 kg. 2 1/2 lb./1.13 kg. 2 3/4 lb./1.22 kg. Base Cap P/N 9000-32069 Description 5 inches Weight 1/8 lb./0.06 kg. Standard Universal 1 1/2”-Diameter Poles Standard Disconnect Head P/N Description 9000-32074 6 inches 9000-32056 6 feet 9000-32057 8 feet 9000-32058 10 feet Weight 1 lb./0.45 kg. 3 1/8 lb./1.41 kg. 3 5/8 lb./1.63 kg. 4 1/8 lb./1.86 kg. Standard Universal Head P/N Description 9000-32072 6 inches 9000-32049 4 feet 9000-32050 6 feet 9000-32051 8 feet 9000-32052 10 feet Weight 1 lb./0.45 kg. 2 7/8 lb./1.29 kg. 3 3/8 lb./1.52 kg. 3 7/8 lb./1.74 kg. 4 1/8 lb./1.86 kg. Extension Section P/N 9000-32065 9000-32066 9000-32067 9000-32068 Description 4 feet 6 feet 8 feet 10 feet Weight 2 lb./0.90 kg. 2 1/2 lb./1.13 kg. 3 lb./1.35 kg. 3 1/2 lb./1.57 kg. Base Cap P/N 9000-32070 Description 5 inches Weight 1/4 lb./0.11 kg. Call Toll Free 1-877-GO ALTEC 12 Standard Disconnect Base Cap Universal Poles and Tool Hangers Universal Poles Designed for use as a hot stick handle for Universal Tools, Chance Universal Poles are made of Epoxiglas® and lightweight aluminum castings. The Universal Tools on this page fit under the thumbscrew of the spline on the Universal Pole for a rigid hot stick tool. For job versatility, the splines allow angling the tool up to 90° in relation to the pole depending upon the individual tool design. The Storm Tool, a Universal Pole with special rubber insulator skirts, is designed for emergency use. It provides extra leakage distance and disrupts water paths when rain, sleet, or snow make regular tools hazardous. Skirts break up streams that would otherwise run down the pole. P/N 9000-01760 9000-17601 9000-17620 9000-17630 9000-17640 9000-17660 9000-17600 9000-17602 9000-17604 9000-01761 9000-01770 9000-17908 9000-17910 9000-17912 9000-17914 Description Pole w/one universal head Pole w/one universal head Rigid splice pole w/one universal head Pole w/two universal heads Pole w/two universal heads Rigid splice pole w/two universal heads Pole w/two universal heads Pole w/two universal heads Pole w/two universal heads Spline storm tool w/two skirts Hinged pole w/one universal head Pole w/two universal heads, pole hanger Pole w/two universal heads Pole w/two universal heads Pole w/two universal heads 9000-04455 Universal head only 9000-44550 Universal head only Hinged Pole Pole Dia. x Length 1 1/4” x 8’ 2” 1 1/4” x 6’ 1” 1 1/4” x 4’ 1”+4’ 1 1/4” x 6’ 3” 1 1/4” x 8’ 3” 1 1/4” x 4’ 1”+4’ 1” 1 1/4” x 10’ 3” 1 1/4” x 12’ 3” 1 1/4” x 14’ 3” 1 1/4” x 8’ 2” 1 1/4” x 8’ 2” 1 1/4” x 8’ 3” 1 1/2” x 10’ 3” 1 1/2” x 10’ 3” 1 1/2” x 10’ 3” Weight 3 lb./.4 kg. 1 3/4 lb./.8 kg. 5 lb./2.3 kg. 2 1/2 lb./1.1 kg. 3 3/4 lb./1.7 kg. 5 3/4 lb./2.6 kg. 4 lb./1.8 kg. 4 1/2 lb./2.0 kg. 5 lb./2.3 kg. 3 1/4 lb./1.5 kg. 4 1/2 lb./2.0 kg. 6 lb./2.7 kg. 6 lb./2.7 kg. 8 lb./3.6 kg. 10 lb./4.5 kg. 1 1/4” 1 1/2” 9 oz./.2 kg. 14 oz./.4 kg. Spliced Pole Universal Fittings for Spliced Poles P/N 9000-17640 P/N 9000-01761 9000-30251 Universal Fitting-Male 9000-30252 Universal Fitting-Female 9000-30253 Universal Fitting-Pair Crossarm Tool Hanger The Chance crossarm tool hanger is adjustable to crossarms ranging in width from 3 1/4 to 4 1/2 inches (depth of the crossarm does not matter). The crossarm tool hanger is made of strong, lightweight aluminum alloy and has cadmium-plated steel hardware. P/N 9000-01860 Crossarm Tool Hanger 2 lb./.9 kg. 13 Hot Stick Care and Storage Accessories Moisture Eater II Cleaner-Solvent Silicone Wipes for hot-line tools Chance’s Moisture Eater II was designed for cleaning contaminated Epoxiglas® found on hot-line tools, line hose and blankets. The new formula consists of two solvents: One for oils, waxes and silicone-type contamination; one for moisture contamination. This combination is ideally suited for cleaning hotline tools. Small pocket-size packets encourage frequent care of insulated hot-line tools. This helps utilities stay in compliance with OSHA 29 CFR 1910.269(j). The hanger box holds 50 wipes to keep them handy in crew bays, on trailers and in trucks. • Stronger solvent for water and conductive contaminants • Safe to earth’s ozone layer: Free of chlorinated hydrocarbons • Pleasant, orange scent from citrus-based component P/N 9000-99613 Description Moisture Eater Cleaner 1 gal. Moisture Eater II Wipes Small pocket-size packets encourage frequent cleaning of insulated hot-line tools, line hose and rubber blankets. This helps utilities stay in compliance with OSHA 29 CFR 1910.269 (j). The convenience of sealed wipes means no more rags to store or try to keep clean in the field. The disposable wipes are easy to use. Just zip open a foil packet, pull out the silicone saturated 8”x10” lint-free towel and wipe down a hotstick. Chance Silicone Wipes contain the same silicone that impregnates hot stick wiping cloths in the Epoxiglas® Cleaning Kit. Using the cloths or Silicone Wipes on fiberglass tools removes dust and deposits a thin protective coat that helps resist accumulation of dirt and other airborne contaminants. The sealed wipes mean no more rags to store or try to keep clean in the field; no more jugs to stow, big spills, evaporation losses or wasteful excesses just to wet large cloths. The hanger box holds 50 wipes to keep them handy in crew bays, on trailers, or in trucks. P/N 9000-02568 Silicone Wipes (Box of 50) P/N 9000-02538 Moisture Eater Wipes (Box of 50) Call Toll Free 1-877-GO ALTEC 14 Hot Stick Care and Storage Accessories Cont. Epoxiglas® Cleaning Kit Hot Stick Storage Tubes The items contained in the Chance Epoxiglas® cleaning kit are essential for the care and maintenance of Epoxiglas® tools and insulated boom sections of aerial lift trucks. The proper use of these maintenance aids will ensure that maximum and useful life is obtained from Epoxiglas® products. WARNING: Do not use on Gel-Coat or painted Chance Hot Stick Storage Tubes are gray linear polyethylene with aluminum end caps and plated hardware. The tubes are furnished with mounting hardware so they can be installed on substation fences or line trucks. boom surfaces. Both end caps have two breather vents to permit condensation or other moisture to evaporate or drain out. Vents will not permit insects to enter tube but will let moisture out. The tube should be installed with the fixed end cap about 1” above the open end so any condensation will drain out the bottom vent in the cap. Tools stored in these tubes are protected against weather, dirt and ultraviolet attack. The polyethylene material is the same that is used in Chance conductor covers, except the color is gray. The gray color was selected to combat ultraviolet damage to the tube itself and to blend with substation fences. The polyethylene has a temperature range of -100°F to 180°F. P/N 9000-99871 Epoxiglas® Cleaning Kit The kit consists of four parts: Moisture Eater II - This cleaner should be used on contaminated Epoxiglas® during general tool maintenance and in prepation for reglossing a tool’s surface. Moisture Eater removes moisture and a wide variety of contaminants such as dirt, tar, grease, tree sap, light metal rubbings and old surface coatings without harming the Epoxiglas® material. The end cap, which can be opened by turning two wing screws, will not fall to the ground when opened to insert or remove a hot line tool, as the cap is secured to the tube. The cap on the other end is permanently secured to the tube. Abrasive Cleaning Pads - These pads are used in conjunction with Moisture Eater to remove contamination that clings to the tools surface. Gloss restorer must be applied after using these pads since cleaning with Moisture Eater 2 will remove the glossy finish on the tool as well as contamination. The pads may also be used on metal parts to remove oxides and surface corrosion. Gloss Restorer Kit - This kit consists of two parts. When mixed and applied to the surface of a cleaned Epoxiglas® tool they combine to form a clear, tough coating that replaces the original gloss and protects against contamination and moisture. Hot Stick Wiping Clothes - Silicone impregnated cloths are used to wipe down mildly contaminated Epoxiglas®, removing dust and dirt, and depositing a thin protective film on the surface of the tool. They give an added measure of protection when used after recoating with gloss restorer. P/N Inside Length 9000-54403 5’ 4” 9000-74403 7’ 4” 9000-94403 9’ 4” 9000-30441 11’ 4” 9000-30443 13’ 4” 9000-30445 15’ 4” 9000-30447 17’ 4” 9000-30449 19’ 4” 9000-30442 21’ 4” Overall Length 5’ 8” 7’ 8” 9’ 8” 11’ 8” 13’ 8” 15’ 8” 17’ 8” 19’ 8” 21’ 8” Approx. Weight 10 1/2 lb./4.8 kg. 12 lb./5.4 kg. 20 lb./6.9 kg. 16 3/4 lb./7.6 kg. 18 lb./8.2 kg. 19 1/2 lb./8.8 kg. 21 lb./9.5 kg. 24.5 lb./11.0 kg. 25.75 lb./11.7 kg. 15 Rubber Insulating Blankets and Line Hose Rubber Insulating Blankets Accessories Performance-designed material Chance Class 4 flexible blankets help protect workers from accidental contact with energized components during line maintenance. Made of ozone/corona-resistant elastomer, these blankets offer excellent performance properties in accordance with ASTM Standard Specification D-1048. The special formulation exhibits superior resistance to long-term aging/checking and will retain its high-visibility orange color. Versatile protection, maximum rating Flexible to cover many irregular shapes, rubber blankets typically are used with conductor covers (flexible or rigid) on deadends, apparatus, secondary racks, poletop pins and crossarms. Because they are Class 4 (highest rating in the industry) and Type II (ozone-resistant), Chance blankets may be used in applications which require lower class or type. Chance blankets are designed with perimeter eyelets to accept Chance button 9700-40591 and most other buttons existing in the field. The 1.5”-diameter center hole in Chance slotted blankets will fit easily around common hardware. P/N 9000-00346 P/N 9700-40588 36” x 36” Solid Blanket 36” x 36” Slotted Blanket P/N 9700-40137 Clamp Pin, Rubber Glove Special handle shape also fits clampstick for easy placement P/N 9000-00531 Clamp Pin, Hot Stick P/N 9700-40591 Rubber Blanket Button Short-Lip Flexible Line Hose Much lighter in weight than other flexible dielectric cover-ups, this orange v-line hose helps protect workers from accidental contact with conductors. The ozone/ corona-resistant thermoplastic elastomer offers excellent performance properties. It does not absorb water. The outer lip peels back with ease to open and starts onto a conductor from either end. With a push at the other end, the full-length slides on as the lips zip closed around the conductor. To remove each piece, open one end and strip the remainder off the conductor. 6 eyelets P/N 9700-16341 Class 2, 1.25” Diameter, 6 Ft length, 5.44 lbs, Coupler on one end Proof Tested at 20kV AC rms P/N 9000-60309 Class 3, 1.5” Diameter, 6 Ft Lengh, 7.2 lbs, Coupler on one end Proof Tested at 30kV AC rms P/N 9000-40629 Class 2, 1.25” Diameter, 6 Ft Length, 4.55 lbs, Straight on both ends P/N 9000-40602 Class 3, 1.5” Diameter, 6 Ft Length, 6.22 lbs, Straight on both ends 28 eyelets Call Toll Free 1-877-GO ALTEC 16 Eyes and special handle shape for easy placement by clampstick Covers Pole Covers These pole covers are used to help protect personnel when raising or lowering a pole between energized lines or to cover poles when rubber glove maintenance is performed in relatively confined areas. The covers are made of high-dielectric linear polyethylene material that will not flash flame. This material will have some softening without deformation at approximately 170°F, and it will resist brittleness at temperatures to -50°F. All Chance pole covers are ribbed to reduce cover contact with the pole, thus minimizing creosote contamination. The rope handles permit personnel to easily spread the covers and snap them around the pole; rubber gloves must be worn during this procedure. Prolonged contact with an energized conductor must not be allowed. 6” Diameter Pole Covers P/N 9700-40577 48” overall length 6.5 lbs P/N 9700-40579 72” overall length 9.5 lbs 9” Diameter Pole Covers P/N 9700-40580 P/N 9700-40582 P/N 9000-49374 P/N 9700-40584 12” Diameter Pole Covers P/N 9700-40586 24” long P/N 9000-04030 48” long P/N 9000-40600 72” long 12” long 24” long 48” long 72” long 2.5 lbs 4 lbs 9 lbs 13 lbs 5.5 lbs 11 lbs 16 lbs Conductor Cover & Insulator Covers These covers provide a highly versatile system of covering up a wide variety of configurations on distribution systems. The units virtually surround the hot parts and hardware to give the linemen extra protection when rubber gloving or using hot sticks. All are made of high density polyethylene in a uniform wall thickness for excellent dielectric/puncture strength, perform well from -50° to 170°F, and are bright orange in color. Conductor covers are 5 feet long and are available with a Grip-All adapter for hot stick application or without adapter for rubber glove application. Maximum conductor size: 666 kcmil ACSR. The conductor covers mate with insulator covers to cover pin-type or post-type insulator construction and also can be used with the deadend cover. The conductor cover will couple with major brands of rubber line hose and insulator covers of the 25kV class. P/N 9000-40601 P/N 9700-22458 P/N 9700-39014 Conductor Cover 25 kV Phase-to-Phase Conductor Cover 36 kV Phase-to-Phase Conductor Cover 9720 kV Plastic Cover Insulator covers come in two heights. Either 12” or 16.5” tall cover fits 6.5” to 9”-diameter pin or post insulators. Special slits in the insulator covers help locate the conductor and hardware when installing the covers. P/N 9700-22454 P/N 9700-40587 12” Insulator Cover 16.5” Insulator Cover 36 kv Phase-to-Phase 36 kv Phase-to-Phase • Tested to ASTM F712 • Manufactured to ASTM F968 specifications • Meet Class 4 requirements 17 Grounding Cable These grounding cables offer supreme flexibility, even at extreme temperatures between -50 degrees C to 105 degrees C. With a high resistance to flame, oil, frease, solvents, ozone, and abrasion, these cables are durable and heavy-duty. Lightweight, with a yellow seoprene jacket, these cables also feature 600-Volt high dielectric strength integrity. MSHA approved. Cable Size #2 Voltage Class: 600 volts Stranding: 19/35/30 Approximate Cable O.D.: .475” Continuous Current 150 Amps at 50-100 ft; 100 Amps at 100+ ft Weight: 270 lbs/1,000 ft Cable Size 2/0 Voltage Class: 600 volts Stranding: 19/70/30 Approximate Cable O.D.: .635” Continuous Current: 300 Amps Weight: 542 lbs/1,000 ft P/N 692-96066 P/N 692-96068 Cable Size 1/0 Voltage Class: 600 volts Stranding: 19/55/30 Approximate Cable O.D: .575” Continuous Current: 250 Amps at 50-100 ft; 250 Amps at 150+ ft Weight: 418 lbs/1,000 ft Cable Size 4/0 Voltage Class: 600 volts Stranding: 19/111/30 Approximate Cable O.D.: .78” Continuous Current 500 Amps Weight: 843 lbs/1,000 ft P/N 692-96067 P/N 9700-34943 Copper Mechanical Jumper Cable Extremely flexible even at low temperatures, this cable features an insulation/jacket combination resistant to abrasion, oil, heat, moisture and ozone. The natural orange color of this mold-cured ethylene-propylene-base coating imparts high visibility. For easy identification, AWG size and voltage rating are embossed at 4-foot intervals. For extended service life, an extruded screen interfaces insulation and conductor. This strand screen improves voltage-stress control by adding dielectric strength and eliminating internal corona. Insulation and conductor screen meet and exceed ICEA-NEMA standard S-68-516. For easy handling in adverse conditions, conductors are extra flexible alloy-coated copper-stranded rope per ASTM B-189 or B-33. Ampacity ratings are based on 90°C conductor temperature at 40°C ambient. Cable Size #2 Voltage Class 15 kV Stranding 259 / No. 26 Approximate Conductor Diameter .322” (8.2 mm) Approximate Cable O.D. .779” (19.8 mm) Continuous Current 200 Amps Weight / Ea. .438 lb (0.199 kg) P/N 9700-40571 Cable Size 1/0 Voltage Class 15 kV Stranding 413 / No. 24 Approximate Conductor Diameter .404” (10.3 mm) Approximate Cable O.D. .863” (21.9 mm) Continuous Current 260 Amps Weight / Ea. .598 lb (0.271 kg) P/N 9700-40574 Cable Size 2/0 Voltage Class 15 kV Stranding 273 / No. 23 Approximate Conductor Diameter .455” (11.6 mm) Approximate Cable O.D. .914” (23.2 mm) Continuous Current 300 Amps Weight / Ea. .707 lb (0.321 kg) P/N 9700-40576 Cable Size 4/0 Voltage Class 15 kV Stranding 473 / No. 21 Approximate Conductor Diameter .602” (15.3 mm) Approximate Cable O.D. 1.065” (27.1 mm) Continuous Current 400 Amps Weight / Ea. 1.047 lb (0.475 kg) P/N 9007-11001 Call Toll Free 1-877-GO ALTEC 18 C-Type Grounding Clamps Weight / Ea. 1.25 lbs. Jaw Opening Size 0.162” to 0.814” Fault Current Rating ASTM Grade 2 Material: Bronze Terminal Type 5/8”-11 Thread Handle Type Eyescrew Jaw Type Smooth Jaws Continuous Current 250 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque: 200 in-lbs (271 N-M) Jumper Range: #2 to 1/0 Cable w/ Threaded Terminal P/N 9700-40149 Jaw Opening Size 0.162” to 0.814” Fault Current Rating ASTM Grade 2 Material: Bronze Terminal Type 5/8”-11 Thread Handle Type Eyescrew Jaw Type Smooth Jaws Continuous Current 250 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque: 200 in-lbs (271 N-M) Jumper Range: #2 to 1/0 Cable w/ Threaded Terminal Weight / Ea. 1.5 lbs. Jaw Opening Size 0.128” to 0.998” Fault Current Rating ASTM Grade 3 Material: Aluminum Terminal Type 5/8”-11 Thread Handle Type Eyescrew Jaw Type Smooth Jaws Continuous Current 300 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque 250 in-lbs Jumper Range: #2 Cable to 2/0 Cable w/ Threaded Terminal Weight / Each: 1 lbs. P/N 9000-61754 Jaw Opening Size 0.162” to 1.25” Fault Current Rating ASTM Grade 5 Material: Bronze Terminal Type 5/8”-11 Thread Handle Type Eyescrew Jaw Type Smooth Jaws Continuous Current 400 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque 250 in-lbs Jumper Range: #2 Cable to 4/0 Cable w/ Threaded Terminal Weight / Each: 1 lbs. P/N 692-96057 P/N 9700-40190 Jaw Opening Size 0.162” to 0.814” Fault Current Rating ASTM Grade 2 Material: Bronze Terminal Type 5/8”-11 Thread Handle Type Eyescrew Jaw Type Smooth Jaws Continuous Current 250 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque: 200 in-lbs (271 N-M) Jumper Range: #2 to 1/0 Cable w/Threaded Terminal Weight/Each: 1 lb Jaw Opening Size 0.128” to 1.25” Fault Current Rating ASTM Grade 5 Material: Aluminum Terminal Type Pressure Handle Type Eyescrew Jaw Type Smooth Jaws Continuous Current 400 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque 250 in-lbs Jumper Range: #2 Cable to 4/0 Cable w/ Plain Terminal Weight / Each: 2 lbs. P/N 9700-37527 P/N 692-96106 19 C-Type Clamps Jaw Opening Size 0.162” to 2” Fault Current Rating ASTM Grade 5 Material: Aluminum Handle Type: Eyescrew Continuous Current 400 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque: 250 in-lbs Terminal Type Pressure Jaw Type Smooth Jaws Weight / Each: 2.75 lbs Jumper Range - #2 to 4/0 Cable w/ Plain Terminal Material: Aluminum Fault Current Rating: ASTM Grade 5 Handle Type: Eyescrew Continuous Current: 400 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque: 250 in-lbs Jaw Opening Size: 0.128” to 1.25” Terminal Type: Pressure Jaw Type: Serrated Jaws Jumper Range: #2 to 4/0 Cable w/ Plain Terminal Weight / Each: 1.5 lbs. P/N 692-96145 P/N 9700-40195 Material: Aluminum Fault Current Rating: ASTM Grade 5 Handle Type: Eyescrew Continuous Current: 400 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque: 250 in-lbs Jaw Opening Size 0.162” to 1.5” Terminal Type 5/8”-11 Thread Jaw Type Smooth Jaws Jumper Range - #2 to 4/0 Cable with Threaded Terminal Weight / Each: 1.25 lbs. P/N 9700-34630 P/N 9700-40193 Material: Aluminum Fault Current Rating: ASTM Grade 5 Handle Type: Eyescrew Continuous Current: 400 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque: 250 in-lbs Jaw Opening Size 0.128” to 1.25) Terminal Type 5/8”-11 Thread Jaw Type Serrated Jaws Jumper Range - #2 to 4/0 Cable with Threaded Terminal Weight / Each: 1 lbs. P/N 9700-40194 Jaw Opening Size 0.162” to 2” Fault Current Rating ASTM Grade 5 Material: Aluminum Handle Type: Eyescrew Continuous Current 400 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque: 250 in-lbs Terminal Type 5/8”-11 Thread Jaw Type Smooth Jaws Weight / Each: 2 lbs. Jumper Range - #2 to 4/0 Cable with Threaded Terminal Jaw Opening Size 0.162” to 2” Fault Current Rating ASTM Grade 5 Material: Aluminum Handle Type: Eyescrew Continuous Current 400 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque: 250 in-lbs Terminal Type Pressure Jaw Type Serrated Jaws Weight / Ea. 2.5 lbs. Jumper Range - #2 to 4/0 Cable w/ Plain Terminal P/N 9700-18946 Call Toll Free 1-877-GO ALTEC 20 Grounding Clamps Flat-Face Clamp Jaw Opening Size 0.125” to 1.5” Jaw Type Serrated Jaws Recommended Torque 250 in-lbs Fault Current Rating ASTM Grade 3 Material Aluminum Terminal Type 5/8”-11 Thread Handle Type Eyescrew Continuous Current 300 Amps Fault Current - 15 cycles 27,000 Amps Fault Current - 30 cycles 20,000 Amps Jumper Range:#2 to 2/0 Cable withThreaded Terminal Weight / Ea. 1.5 lbs. P/N 9700-40203 Flat-Face Clamp Jaw Opening Size 0.125” to 1.5” Fault Current Rating ASTM Grade 5 Material Bronze Terminal Type 5/8”-11 Thread Handle Type Eyescrew Jaw Type Serrated Jaws Continuous Current 400 Amps Fault Current - 15 cycles 43,000 Amps Fault Current - 30 cycles 30,000 Amps Recommended Torque 250 in-lbs Jumper Range:#2 to 4/0 Cable with Threaded Terminal P/N 9700-40209 Flat-Face Clamp Jaw Opening Size 0.125” to 1.5” Jaw Type Serrated Jaws Recommended Torque 250 in-lbs Fault Current Rating ASTM Grade 3 Material Aluminum Terminal Type Pressure Handle Type Eyescrew Continuous Current 300 Amps Fault Current - 15 cycles 27,000 Amps Fault Current - 30 cycles 20,000 Amps Jumper Range:#2 to 2/0 Cable with Plain Terminal Weight / Ea. 1.5 lbs. P/N 9700-40211 Flat-Face Clamp Jaw Opening Size 0.125” to 1.5” Jaw Type Serrated Jaws Recommended Torque 250 in-lbs Fault Current Rating ASTM Grade 5 Material Bronze Terminal Type 5/8”-11 Thread Handle Type T-Handle Continuous Current 400 Amps Fault Current - 15 cycles 43,000 Amps Fault Current - 30 cycles 30,000 Amps Jumper Range:#2 to 4/0 Cable with Threaded Terminal Weight / Ea. 4 lbs. P/N 692-96109 Jaw Opening Size 0.125” to 1.5” Fault Current Rating ASTM Grade 3 Material Aluminum Terminal Type 5/8”-11 Thread Handle Type T-Handle Jaw Type Serrated Jaws Continuous Current 300 Amps Fault Current - 15 cycles 27,000 Amps Fault Current - 30 cycles 20,000 Amps Recommended Torque 250 in-lbs Jumper Range:#2 to 2/0 Cable with Threaded Terminal Weight / Ea. 1.5 lbs. P/N 9000-61798 Jaw Opening Size 0.162” to 2” Fault Current Rating ASTM Grade 5 Material: Aluminum Terminal Type 5/8”-11 Thread Handle Type Eyescrew Jaw Type Serrated Jaws Continuous Current 400 Amps Fault Current 15 cycles 43,000 Amps 30 cycles 30,000 Amps Recommended Torque 250 in-lbs Jumper Range:#2 to 4/0 Cable with Threaded Terminal Weight / Ea. 1.75 lbs. P/N 9007-02256 21 Ferrules and Jumper Cables Grounding Ferrules Jumper Clamps Shrouded ferrules overlap onto the grounding cable jacket for stress relief to the terminal. Two crimps secure the ferrule against the bare strands and one crimp applies on the jacket. Unshrouded ferrules are available with shrink tubing that overlaps the bare cable conductor and jacket for stress relief. Available either factory-installed in pairs on any cable length specified or as separate individual units, the ferrules install simply with a hydraulic crimping tool. Complete illustrated installation instructions come with the ferrules and include a table for the crimping die sizes to use. The G4758 series jumper clamp has a handle length of 5.625” below the handguard. The bearing type floating washer lower contact improves gripping action and prevents conductor scoring. All metal parts are made of copper alloy to improve resistance to oxidation. The 300 amp continuous current rating is based on using 2/0 jumper cable on the tap side. Voltage Class 15 kV Main Line Range: 162” to .721” Jumper Cable Range: #2 to 2/0 Cable Weight / Ea. 2.25 lb P/N 9700-40135 The G4765 series jumper clamp has the same polyethylene material in the handle as other Chance jumper clamps. The handle length below the handguard is 7.5”. The 400 amp continuous current rating is based on using 4/0 jumper cable on the tap side. Shrouded Plain Copper Ferrules for pressure-type grounding-clamp terminals P/N P/N P/N P/N 692-96140 9700-40141 9700-40142 9700-40144 Cable Size #2 Cable Size 1/0 Cable Size 2/0 Cable Size 4/0 Voltage Class 25 kV Main Line Range: .162” to .883” Jumper Cable Range: #2 to 4/0 Cable Weight / Ea. 2.75 lb P/N 9700-05084 Unshrouded Plain Copper Ferrules for pressure-type grounding-clamp terminals P/N P/N P/N P/N 9700-40145 692-96133 692-96117 9700-40146 Cable Size #2 Cable Size 1/0 Cable Size 2/0 Cable Size 4/0 Shrouded, Threaded-Stud Copper Ferrules for tapped or drilled grounding-clamp terminals P/N P/N P/N P/N 9000-02622 692-96125 9700-34631 8110-01191 Cable Size #2 Cable Size 1/0 Cable Size 2/0 Cable Size 4/0 Unshrouded, Threaded-Stud Copper Ferrules for tapped or drilled grounding-clamp terminals P/N P/N P/N P/N 692-96058 9700-40147 9700-40148 9007-02609 Cable Size #2 Cable Size 1/0 Cable Size 2/0 Cable Size 4/0 Voltage Class 35 kV Main Line Range, .162” to 1.165” Jumper Cable Range, #2 to 4/0 Cable Weight / Ea. 3 lb P/N 9700-40136 Call Toll Free 1-877-GO ALTEC 22 The G4775 series Jumper Clamp has a larger contact opening for use on larger contact opening for use on larger conductor distribution lines. The handle length below the handguard is 8.375”. Easy to assemble, the connector assemblies are interchangeable between the two sizes of 15 kV Jumper Clamps. The 400 amp continuous current rating is based on using 4/0 Jumper Cable on the tap side. Grounding & Mechanical Jumper Assemblies Grounding assemblies can be fabricated with #2, 1/0, 2/0, or 4/0 600 Volt yellow or orange 25kV cable, hotstick or barehand clamps, and threaded or unthreaded ferrules. Grounding assemblies are tested for resistance, tagged with resistance value and date-tested. Heat shrink is applied to protect from water penetration. Contact your nearest Altec representative at 1-877-GO ALTEC to create a grounding assembly to best meet your needs. 23 Contact Altec for all of your parts and accessory requirements. 1-877-GO ALTEC