Preview only show first 10 pages with watermark. For full document please download

Top Ducts – Cable Pathway

   EMBED


Share

Transcript

version: 19-03-2013 CONTEG DATASHEET CABLE MANAGEMENT Top Ducts – Cable Pathway CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420 261 219 182 Fax: +420 261 219 192 Production plant in the Czech Republic: K Silu 2179 393 01 Pelhřimov Tel.: +420 565 300 300 Fax: +420 565 533 955 All rights reserved, CONTEG © 2013 Local Branches/Offices Austria: Benelux: Eastern Europe / Nordics: France, Maghreb: Germany / Switzerland / Baltics / Denmark / Italy: Middle East: Russia, CIS: +420 724 723 184 +32 477 957 126 +49 172 8484 346 +33 686 074 386 +49 170 523 4958 +971 555 08 32 41 +7 495 967 3840 [email protected] www.conteg.com www.conteg.com 1 Top ducts are designed to provide safe, easy-to-use, and cost-effective management system for copper cables above the racks. Top ducts are simple to install and at the same time allow for easy installation, manipulation, and re-patching of cooper cables between server, network and UPS racks. The system is designed to provide a simple connection between the rack rows without ceiling or other exterior support. This solution reduces the installation time and the rack layout can be easily changed. The connection between rack rows can be multi-layered and can be combined with the Conteg Optiway pathway system to provide independent routes for fiber cables. The solution complies with market requirements, recommendations, and best practices. MAIN COMPONENTS: • Top duct • Cross connection • Radius protectors and accessories • Supporting brackets for use with Conteg Optiway pathway system • Supporting brackets for use without Conteg Optiway pathway system • Accessories for cable management Top Ducts The top duct solution provides a backbone cable management system above a rack. The basic length segments correspond with the rack’s width and can be easily removed and later installed back in without affecting neighboring racks. All cable ducts can be covered by toolless covers. The main duct has perforations and can be used with all cover types and their combinations. The duct profile is 200 x 70 mm. The end member length of 350 mm is recommended for places where it is not possible to use a full length cable duct. Code CPW-20TD30 CPW-20TD40 CPW-20TD60 CPW-20TD80 CPW-20TD35 CPW-20TDC80 CPW-20TD80 All rights reserved, CONTEG © 2013 CPW-20TDC10 CPW-20TDC20 CPW-20TDC30 CPW-20TDC40 CPW-20TDC50 CPW-20TDC60 CPW-20TDC80 CPW-20TDC35 H Main duct 70 70 70 70 70 Cover W L 200 200 200 200 200 300 400 600 800 350 200 200 200 200 200 200 200 200 100 200 300 400 500 600 800 350 www.conteg.com 2 Top Ducts - Cross Connection The cross connection duct allows a cable management system to be installed across one or more rack rows. It includes several adjustable features enabling to achieve the required duct length on a multilevel basis. Ducts can be covered by tool-less covers. Code CPW-20CD100 CPW-20CD140 CPW-20CD180 CPW-20CD220 CPW-20CD260 CPW-20CDC100 CPW-20CDC140 CPW-20CDC180 CPW-20CDC220 CPW-20CDC260 H W Cross connection 70 200 70 200 70 200 70 200 70 200 Cover 200 200 200 200 200 L CPW-20CDC260 1034 – 1480 1434 – 2280 1834 – 3080 2234 – 3880 2634 – 4680 CPW-20CD260 1034 – 1480 1434 – 2280 1834 – 3080 2234 – 3880 2634 – 4680 Top Ducts accessories Used for multilevel cross connection. The system can be used with/without contained aisle solutions for racks that are 42U, 45U or 48U in height. CPW-20CA CPW-20-R10 Code CPW-20CA CPW-20CC-SM CPW-20CAC-0U CPW-20CAC-3U CPW-20TAC-0U CPW-20TAC-3U CPW-20-R17 CPW-20-R10 CPW-20-R20 CPW-20-EC CPW-20-CC DP-KP-LEM HDWM-VCT HDWM-VCT-B HDWM-VCT-S CPW-20CC-SM CPW-20-R17 CPW-20CAC-0U CPW-20CAC-3U CPW-20-R20 CPW-20TAC-0U CPW-20-EC CPW-20TAC-3U CPW-20-CC Description Cross and Tee members – for multilevel intersection Cross member between CPW-20TDxx and 2x CPW-20CDxx (for CPW-20CDxx when using crosswise) Set of 2 support brackets for CPW-20CDxx; only for CCA with 42U racks or for crossover Cover for cross member CPW-20CA Cover for cross member CPW-20CA, offset use Cover of tee connection from CPW-20CDxx to CPW-20TDxx when 45U and 48U racks are used Cover of tee connection from CPW-20CDxx to CPW-20TDxx when CCA or CPW-20CC-SM are used; only for 42U racks Cable Duct accessories Radius cable protection for CPW-20TDxx, 170 mm width; 2 pieces with plastic pins Radius cable protection for CPW-20TDxx, 100 mm width; 2 pieces with plastic pins Radius cable protection for end of CPW-20TDxx or CPW-20CDxx, 200 mm width; 2 pieces with plastic pins End cap of CPW-20TDxx; 2 pieces Connecting kit for CPW-20TDxx for direct application on roof of rack, pack of 10, not necessary when using CPW-RRB-xx Cable management Rubber piece for edges of 790 mm cable entry opening Velcro cable ties, 25 mm x 300 mm, pack of 10, black Velcro cable belt, 13 mm x 5000 mm, 1 piece, black Velcro cable ties-small, 13 mm x 190 mm, pack of 25, black Supporting Brackets Top ducts can be installed directly onto the roof of the rack with or without the Optiway pathway system. The supporting brackets that are intended for use without Optiway can be easily installed and adjusted above the racks. The supporting brackets that are intended for use with Optiway combine both the Optiway and top duct systems. These supporting brackets are equipped with holes for the threaded rods used to support the Optiway system at different levels. See next page for information table of supporting brackets. All rights reserved, CONTEG © 2013 www.conteg.com 3 Code Bracket length in mm CPW-BR-BR CPW-RRB-40 400 CPW-RRB-50 500 CPW-RRB-60 600 CPW-RRB-80 800 CPWRRB-100 1000 CPWRRB-120 1200 Code Type of mounting Supporting brackets without Optiway Top duct bracket for installation of CPW-RRB on racks RSF/RDF/RHF Top duct half-size mounting bracket for installation of cable duct CPW-20TDxx on roof of rack, 80 cm depth Top duct half-size mounting bracket for installation of cable duct CPW-20TDxx on roof of rack, 100 cm depth Top duct half-size mounting bracket for installation of cable duct CPW-20TDxx on roof of rack, 120 cm depth Top duct full-size mounting bracket for installation of cable duct CPW-20TDxx on roof of rack, 80 cm depth Top duct full-size mounting bracket for installation of cable duct CPW-20TDxx on roof of rack, 100 cm depth Top duct full-size mounting bracket for installation of cable duct CPW-20TDxx on roof of rack, 120 cm depth Bracket length in mm OPW-TR-BR OPW-TR-16/20 OPW-TR-16/40 OPW-TR-16/60 OPW-TR-16/100 OPW-TR-16/200 OPW-TR-CM 210 400 600 1000 2000 200 CPW-ORB-40 400 CPW-ORB-50 500 CPW-ORB-60 600 CPW-ORB-80 800 CPW-ORB-100 1000 CPW-ORB-120 1200 CPW-CDB Recommended rack depth in mm Mounting holes 800 2 CPW-ORB-100 1000 2 1200 2 800 3 1000 3 1200 3 CPW-RRB-100 CPW-BR-BR Type of mounting Supporting brackets with Optiway Bracket for installing threaded rod on racks RSF/RDF/RHF. Rack mounting threaded rod for Optiway, M16, 21 cm length Rack mounting threaded rod for Optiway, M16, 40 cm length Rack mounting threaded rod for Optiway, M16, 60 cm length Threaded rod for Optiway, M16, 100 cm length Threaded rod for Optiway, M16, 200 cm length Optiway-ceiling mounting holder for threaded rod Top duct half-size mounting bracket for installing cable duct CPW-20TDxx on roof of rack, 80 cm depth; used with Optiway (OPW-TR-BR and OPW-TR-16/xx needed) Top duct half-size mounting bracket for installing cable duct CPW-20TDxx on roof of rack, 100 cm depth; used with Optiway (OPW-TR-BR and OPW-TR-16/xx needed) Top duct half-size mounting bracket for installing cable duct CPW-20TDxx on roof of rack, 120 cm depth; used with Optiway (OPW-TR-BR and OPW-TR-16/xx needed) Top duct full-size mounting bracket for installing cable duct CPW-20TDxx on roof of rack, 80 cm depth; used with Optiway (OPW-TR-BR and OPW-TR-16/xx needed) Top duct full-size mounting bracket for installing cable duct CPW-20TDxx on roof of rack, 100 cm depth; used with Optiway (OPW-TR-BR and OPW-TR-16/xx needed) Top duct full-size mounting bracket for installing cable duct CPW-20TDxx on roof of rack, 120 cm depth; used with Optiway (OPW-TR-BR and OPW-TR-16/xx needed) Top duct cross connection support - rack or ceeling installation (used with threaded rods and mounting brackets) Top Duct detail 1 Recommended rack depth in mm Mounting holes 800 2 1000 2 1200 2 800 3 1000 3 1200 3 2 Top Duct detail 2 All rights reserved, CONTEG © 2013 www.conteg.com 4