Preview only show first 10 pages with watermark. For full document please download

Total Solution Catalogue For Web

   EMBED


Share

Transcript

Conventional 4-wire detectors Conventional 4-wire detection: The FAP6 range Introducing the FAP6 range of detectors, for use with the Firetec and Eurofire 4-wire panels. FAP6 provides proven technology in a slim package, the concise range comprises optical and heat detectors (fixed and rate of rise temperature). In conjunction with Firetec the range is suited to small to medium sized buildings. Detector base with diode FAP6-STB The standard detector base has a diode fitted beneath the connectors. SPECIFICATION Termination Connectors accept up to 2.5mm2 cables Construction White moulded polycarbonate Dimensions ø d (mm) 100 x 15 Weight g 60 FAP6-STB Relay base FAP6-RLB The relay base incorporates a set of volt-free changeover contacts, which will latch when the detector registers an alarm. SPECIFICATION FAP6-RLB 60 Voltage range 9 – 33Vdc Relay base alarm current at 24V 17mA Modes Latching Operating temperature -20 to +70ºC Termination Connectors accept up to 2.5mm2 cables Construction White moulded polycarbonate Dimensions ø d (mm) 100, 25 Weight g 100 FAP6 is based on series 65 technology from Apollo Fire Detectors Ltd Conventional | Conventional 4-wire detectors www.emergi-lite.co.uk Conventional 4-wire detectors Relay base, 12 volt FAP6-RLB12 The low voltage relay base incorporates a set of volt-free changeover contacts that can be used for either latching or non-latching (security system) purposes. To enable control of an automatic door closer, for example. SPECIFICATION Voltage range 9 – 15Vdc Average quiescent current at 12V <10µA Relay base alarm current, at 12V 20mA Modes Latching or non-latching Operating temperature –20 to +70ºC Termination Connectors accept up to 2.5mm2 cables Construction White moulded polycarbonate Dimensions ø d (mm) 100, 25 Weight g 100 Optical smoke detector FAP6-RLB12 FAP6-OPT The optical detector measures the level of smoke particles using light scatter, going to alarm at a pre-set threshold. New optics help reduce false alarms while stability is strengthened by using internal software control. Recommended for general purpose use to give early warning of fire. SPECIFICATION Voltage range 8.5 – 33Vdc Average quiescent current at 24V 65µA Alarm current at 12V 24V 20mA 40mA Alarm indication Clear LED, red on alarm Operating temperature -20 to +60ºC Wiring & polarity 2 wire supply, polarity sensitive Construction White moulded polycarbonate Dimensions ø d (mm) 100 x 42 (100 x 50 inc base) Weight g 99, 150 with base Standards EN54-7: 2000 FAP6-OPT 61 www.emergi-lite.co.uk Conventional 4-wire detectors | Conventional Conventional 4-wire detectors Heat detector – FAP6-FT8 fixed temperature The fixed (static) heat detector will trigger when a pre-set upper temperature threshold is exceeded at the sensor. SPECIFICATION FAP6-FT8 Voltage range 9 – 33Vdc Quiescent current at 24V <50µA Alarm current at 9V 24V 17mA 52mA Alarm indication Red LED Operating temperature –20 to +90ºC Wiring & polarity 2 wire supply, polarity sensitive Construction White moulded polycarbonate Dimensions ø d (mm) 100 x 42 (100 x 50 inc base) Weight g 80, 131 with base Standards EN54-5: 2000 Heat detector – Rate of rise FAP6-RR6, FAP6-RR75, FAP6-RR90 The heat detector will monitor the rate of temperature increase in the vicinity and will also be triggered when a fixed upper threshold temperature level is exceeded. Classification – maximum application temperature: RR6= 50ºC, RR75 = 65ºC, RR90 = 80ºC SPECIFICATION FAP6-RR6 Voltage range 9 – 33Vdc Quiescent current at 24V <50µA Alarm current at 9V 24V 17mA 52mA Alarm indication Red LED Operating temperature –20 to +90ºC Wiring & polarity 2 wire supply, polarity sensitive Construction White moulded polycarbonate Dimensions ø d (mm) 100 x 42 (100 x 50 inc base) Weight g 80, 131 with base Standards EN54-7: 2000 STANDARD ORDER CODE DESCRIPTION FAP6-RR6 Heat detector – Rate of rise with fixed upper threshold 50ºC, A1R FAP6-RR75 Heat detector – Rate of rise with fixed upper threshold 65ºC, BR FAP6-RR90 Heat detector – Rate of rise with fixed upper threshold 80ºC, CR 62 Conventional | Conventional 4-wire detectors www.emergi-lite.co.uk