Contents Safety precautions / Explanation of warning signals
5
Delivery extent
6
Functional description
7
Technical data
7
Information for the installer
8
Control box General notes Housing installation Wiring diagram Power supply Connecting 230VAC motors Connecting decentralised controls Assembly / Connection of wind sensors Assembly / Connection of lux sensors Assembly / Connection of rain sensors Assembly / Connection of temperature sensors Assembly / Connection of DCF radio-controlled clock receiver Connection of buttons for external operation of channel groups Connection the maintenance switch Connecting the control system to a smoke/fire alarm system
8 8 9 10-11 12 13 14 15-16 16-17 18-19 20-21 21-22 23 24 25
Display box Connecting the display box to the control box via 4-wire interface
26 26-27
Installation assistant (Wizard) Quick reference guide General notes Password input Wizard start Setting the user interface language Communication mode recognition Scanning connected sensor devices Selection of connected channel group Selection of sensors from connected sensor devices Lux sensor assignment Wind sensor assignment / Wind sensor type setting Temperature sensor assignment Rain sensor assignment Activating the device lock function Wizard end
28 28 29 29 29 29 30 30 31 31 32 32 33 33 33-34 34
© Vestamatic GmbH
-2-
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
2-4
Contents
Information for the user
35 35-36 36-37
General notes Weather info / Display lock / Comfort program
Detail 1/3 Setting the time / date Setting the display colour selection Setting the display standby time Release following fire alarm
39 39 40 40 40
Detail 2/3 Network settings (without function) Display logbook Display contact details Display software version and serial number
41 41 41 42 42
Detail 3/3 Move to safety position Touchscreen calibration Display/Start wizard Restore factory settings
42 42 43 43 44
45 45
Fine adjustments Quick reference guide Detail 1/5 Sun function Setting extension sun threshold Setting extension response time Setting retract time delay Setting retract sun threshold Setting sun motor runtime Setting number of sun-dependent extension commands per day Rain function Setting rain reset delay Setting rain sensitivity setting Setting manual extension when rain/frost Wind function Setting wind threshold 1 Setting wind threshold 2 Setting wind response delay Setting wind reset delay Setting wind unit Temperature function Setting temperature threshold 1 Setting temperature threshold 2 Setting motor run time for temperature threshold 2 Setting temperature reset delay Setting temperature unit © Vestamatic GmbH
-3-
46 46 46 47 47 47 47 48 48 48 48 49 49 50 50 51 51 51 52 52 52 53 53 53 Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
38 38
Basic settings Quick reference guide
Detail 2/5 Motor run time Tilting function Selection of tilting type Setting tilting time “season” Setting tilting time “table” Setting tilting assignment Continuous up command / Continuous down command
54 54 54 55 56 56 56 57
Detail 3/5 MC DZ M/J function Inching mode function Holiday function Astro function Astro setting Setting longitude LON Setting latitude LAT Setting up time correction Setting down time correction
58 58 58 59 59 59 60 60 60 60
Detail 4/5 UP time function DOWN time function Automatic mode lock Programming/deleting handheld transmitter (without function)
61 61 62 62 63
Detail 5/5 Heating function Setting temperature threshold Setting anti-freeze Setting reset delay Setting temperature unit Ventilation function Setting temperature threshold Setting reset delay Setting temperature unit
63 63 64 64 64 64 65 65 65 65
Control system warning signals
66
List of cities for the Astro function
67
Symbol description
68-72
Manufacturer’s default settings
73-75
Personal settings
76-78
Troubleshooting
79-81
Cleaning / Disposal of waste
82
Customer service
82
© Vestamatic GmbH
-4-
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Contents
Safety precautions / Explanation of warning signals
– For safety reasons, if a severe weather warning is issued, retract all connected devices and change the operating mode of all groups to manual operation mode.
Ä Danger
Ä
There is an imminent danger to the life and health of personnel. Any failure to follow the hazard warnings will immediately put personnel at risk.
There is a potential danger to the life and health of personnel.
Warning
Ä Caution
Ä
A situation which has an undesirable consequence. The extent of health damage is small. Example: foreseeable operating errors.
Material damage to the device may result if the hazard warnings are not followed.
Attention
I
Failure to comply will result in product handling faults, but not in damage to property or personal injury.
h
Application advice and useful information on how to make best use of the product.
© Vestamatic GmbH
-5-
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Ä
– Contact a professional electrician to install the control system, because the control system requires a power supply of 230VAC, 50 Hz. – Check the control system for signs of mechanical damage after unpacking. If you notice any shipping damage, do not start up the control system and notify your supplier immediately. – The control should only be used for the purpose specified by the manufacturer (refer to the operating instructions). Any changes or modifications thereof are not permissible and will result in loss of all warranty claims. – If it is no longer possible to guarantee the safe operation of the control or the connected devices, you should turn the control off immediately and make sure that it cannot be operated unintentionally. – Before carrying out work on sunshading devices or skylights which are operated by the control, you must switch off the control box power supply. – For safety reasons, if there is no rain or frost sensor connected to the control you are advised, depending on the sunshade design, to set the control to manual operation if the temperature drops below +1 °C. This will prevent the sunshade from extending automatically (e.g. due to the sun). – This device contains a pollutant battery. The end user must recycle all used batteries in accordance with regulation 91/157/EWG). Disposing of the batteries in household waste is strictly forbidden. – The use of a power pack other than the optional power pack supplied by the control’s manufacturer may limit the functions available and/or damage the control. Such use is therefore not permitted. – In the event of a power failure, the control and all connected devices will no longer be operable.
Delivery extent The following items are included:
1ß
and
2ß
3ß
4ß
5ß
1ß Control device comprising display box and control box Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
2ß Wall mounting plate for display box 3ß Installation instructions 4ß Operating instructions on CD 5ß Stylus Touch Centre versions: Touch Centre XL 4C Wired Touch Centre M 2C Wired
Article-no.: 01080212 Article-no.: 01080210
Accessories: Lux sensor LS 30 Wind sensor WS XS Wind sensor WS XS Alu Wind sensor WS Classic M Power supply PS Classic M (for WS Classic M) Rain sensor RD +1 °C Rain sensor RD -20 °C Temperature sensor TS Pro XL Thermostat TE Indoor Thermostat TE Outdoor DCF Receiver
Article-no.: 01161210 Article-no.: 01100310 Article-no.: 01100410 Article-no.: 01100235 Article-no.: 01100290 Article-no.: 010830 Article-no.: 010825 Article-no.: 01173010 Article-no.: 01100271 Article-no.: 01100282 Article-no.: 01306300
© Vestamatic GmbH
-6-
Subject to modifications!
Functional description The Touch Centre is a microprocessor-controlled central control for different products such as blinds, awnings, shutters, skylights, ventilation systems, heating and lighting. The control system is intended for use in medium-sized projects with up to 4 façades and/or floors. The connected sunshade and locking systems are centrally controlled according to sun intensity, wind speed, precipitation and time. External systems, such as safety windows, fire alarms or building control services systems, can be easily integrated. The sensor inputs make it possible to connect simultaneously (depending on control system type) up to: 2 wind sensors (heated / not heated) 8 lux sensors 1 rain sensor 2 Temperature sensors 1 DCF 77 Receiver Additional connections: 4 up/down group buttons 1 maintenance switch 1 connection for fire alarm centers The display box controls and communicates via the in-built 4-wire RS485 interface. Operating and setting the connected sunshade devices is simple thanks to the coloured touchscreen display in the display box with its clear symbol options.
Power supply:
230VAC, 50 Hz
Impulse voltage withstand level:
2.5 kV
Rated power:
10 W
Max. load per output: Max. rated power:
250VAC, 4A, cos f > 0.8 ind. 1380 W, 6A, 230VAC
Align switching time extend:
3 – 180 seconds or continuously
Software class:
A
Operating temperature:
0°C (32°F) to +40°C (104°F)
IP class:
IP 54 (control box) IP 20 (display box)
Degree of contamination:
2 (control box) 2 (display box)
Battery:
CR 2032
Dimensions (L × W × H):
270 × 220 × 108 mm (control box) 155 × 105 × 35 mm (display box)
Colour information:
Display box: black (similar to RAL 9005) / standard version Control box: light grey (similar to RAL 7035)
Mark of conformity:
p
© Vestamatic GmbH
-7-
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Technical data
Information for the installer – Control box
General notes Connecting skylight motors
Ä
ATTENTION! When connecting skylights, the terminal UP corresponds to the close skylight command, and the terminal DOWN corresponds to the open skylight command.
Connecting fan motors or heating/lighting fittings
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Ä
ATTENTION! – When connecting fan motors or heating/lighting fittings the terminal UP corresponds to the command fan/heating/lighting ON. – The terminal DOWN does not have a function in the case of fan motors or heating/ lighting fittings. – Check the rated power of the connected devices. The total power consumption of the connected devices must not exceed 1380 W. If the power consumption of the connected devices exceeds 1380 W, the isolating relay MC TR 1 PF (01054720) must be used for each channel group.
© Vestamatic GmbH
-8-
Subject to modifications!
Information for the installer – Control box
Housing installation
Ä
WARNING! Risk of injury due to improper installation and commissioning. Improper installation and commissioning may lead to personal injury or property damage. Therefore: – When connecting the device, observe the currently valid VDE standards (in particular DIN VDE 0100/0700), your local power company’s regulations and the current accident prevention regulations. – Connect the control in accordance with the wiring diagram.
1. Switch off the power supply 2. Unscrew the housing cover, take off the housing cover of the control box and mount the housing at the outer four drill holes in the corners. The housing must be mounted such that the cable glands are located underneath. The control box must be mounted in a position that is well protected from direct sunlight. 3. Feed the cables through the cable inlets in the housing and tighten the inlet. Unused cable inlets must be sealed. 4. Connect the cables in accordance with the wiring diagram.
5. The output is floating (important for operating decentralised controls). 6. If one or more motors (230VAC, 50 Hz) resp. isolating relays are directly connected, a wire bridge must be fitted between terminal Common of the motor output and terminal L of the mains connection. 7. Replace the housing cover and tighten the housing cover screws.
© Vestamatic GmbH
-9-
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
I
NOTE! Mount the control device so that it is inaccessible to adults, children and animals. All cables must be permanently wired.
Information for the installer – Control box
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Wiring diagram
© Vestamatic GmbH
- 10 -
Subject to modifications!
Information for the installer – Control box
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Wiring diagram
© Vestamatic GmbH
- 11 -
Subject to modifications!
Information for the installer – Control box
Power supply
The control system is connected to the mains (230VAC, 50 Hz) via the terminals L, N and PE. Terminals with the same potential are connected to each other internally.
© Vestamatic GmbH
- 12 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Figure: Power supply
Information for the installer – Control box
Connecting 230VAC motors The control system is designed for the direct connection of 4 × 230VAC motors. The total power consumption of the motors must not exceed 1380 W. Each output has its own terminal for retraction/exten-sion/neutral- and ground conductor and is protected via a common 6.3 AT fine-wire fuse in the control system.
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
I
NOTICES! – When directly connecting 230VAC motors, also fit a wire bridge with a cross section of 1.5 mm2 between the terminals L and Common. – No terminals Mot. 3 up to Mot. 4 down for version M 2C Wired are available.
Figure.: Wire bridge and direct connection of 230VAC motors
© Vestamatic GmbH
- 13 -
Subject to modifications!
Information for the installer – Control box
Connecting decentralised controls The control system is designed for the connection of decentralised controls. The switching current of the decentralised controls must not exceed 6 A. Each output has its own terminal for retraction and extension and is protected via a common 6.3 AT fine-wire fuse in the control system.
I
© Vestamatic GmbH
NOTE! No terminals Mot. 3 up to Mot. 4 down for version M 2C Wired are available.
- 14 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Ä
ATTENTION! – When connecting decentralised control devices, do NOT fit a wire bridge between the terminals L and Common. Fitting a wire bridge will destroy all connected decentralised controls! – It is NOT permitted to operate floating controls and 230VAC motors at the outputs of the control at the same time. If you need to operate motors and decentralised controls, an isolating relay MC TR 1 PF (01054720) must be used for each channel group that requires a floating output.
Information for the installer – Control box
Assembly / Connection of wind sensors
Ä
ATTENTION! It is not permitted to have two different types of wind sensors or other manufacturers’ wind sensors connected at the same time. This may cause serious personal injury or damage to property.
Operation The wind sensor is used for recording non-directional measurements of outdoor horizontal air flow. The wind sensor has a compact design and is fitted with a reed contact which converts the wind speed into an electrical signal. These signals are produced by the reed contact which is closed by a magnetic field. A shaft, which is attached to the anemometer and runs in a ball or plain bearing, passes the magnet over the reed contact at a frequency which is proportional to the anemometer speed, and therefore also to the wind speed. The measured values are converted into digital electrical signals and transmitted to the control system. It is also possible to detect a rupture of the wind sensor cable.
Choice of assembly location Wind gauge devices should generally cover the wind conditions within a wide perimeter. In order to obtain comparable values when determining surface wind, measuring should take place at a height of 10 m above level, undisturbed ground. Undisturbed ground means that the distance between the wind sensor and any obstacle should be at least ten times the height of the obstacle (see VDI 3786). If it is not possible to comply with this requirement, the wind sensor should be set up at a height at which the measured values are, as far as possible, not influenced by local obstacles (approx. 6 m to 10 m above disturbance level). In the case of flat roofs, the wind sensor should be set up in the middle of the roof and not at the roof edge in order to avoid possible prevailing wind directions.
Maintenance / Cleaning If the device is subject to extreme weather conditions, it may only be assembled and operated in a vertical position, otherwise water could penetrate the device and impair its function. If the device is installed properly, it will work maintenance-free. If the sensor becomes excessively soiled, it can be cleaned with standard household cleaning products as long as they do not contain any aggressive or abrasive ingredients.
Cable lengths If the 5 m signal cable is too short, it can be extended up to 100 m using the same cross section.
© Vestamatic GmbH
- 15 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Assembly of the wind sensor The wind sensor is installed either with the aluminium mounting bracket article-no. 01100510 or with the plastic mounting bracket article-no. 01271020. Align so that the cable inlet is pointing downwards. Use clips, cable ties or similar fasteners to attach the measuring cable securely to the mounting bracket so that the cable cannot be damaged by flapping and fraying during high winds.
Information for the installer – Control box Terminals The two wind sensors are connected to the terminals Wind 1 and GND and Wind 2 and GND at the control box. The polarity of the wind sensors is not important for connection.
Ä
ATTENTION! It is not permitted to have two different types of wind sensors connected at the same time. Is no wind sensor connected, the terminals of the windsensor have to be bridged by a wire bridge.
Assembly / Connection of lux sensors Operation The lux sensor is used to record natural light intensity and is adjusted to eye sensitivity. The measured sun intensity is transformed into electrical analogue signals. These are evaluated by the control system, which triggers the corresponding control commands.
Assembly of lux sensor LS 30 The lux sensor LS 30 can be installed on the aluminium mounting bracket article-no. 01100510, on the plastic mounting bracket article-no. 01271020, or using the angled aluminium mounting bracket supplied. Align so that the cable inlet is pointing downwards. Use clips, cable ties or similar fasteners to attach the measuring cable securely to the mounting bracket so that the cable cannot be damaged by flapping and fraying during high winds.
© Vestamatic GmbH
- 16 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Figure: Connection samples for wind sensors
Information for the installer – Control box Choice of assembly location The lux sensor LS 30 has a sensing range of approx. 120°. When assembling the lux sensor, attention must be paid to obstacles which might distort the sun intensity and therefore influence the measured values. In the case of large building façades, there should always be two lux sensors installed at an angle of 45° to each other. This will ensure optimal sun intensity detection throughout the year.
Maintenance / Cleaning If the device is subject to extreme weather conditions, it may only be assembled and operated in a vertical position, otherwise water could penetrate the device and impair its function. If the device is installed properly, it will work maintenance-free. If the sensor becomes excessively soiled, it can be cleaned with standard household cleaning products as long as they do not contain any aggressive or abrasive ingredients.
Cable lengths If the 5 m signal cable is too short, it can be extended up to 100 m using the same cross section.
Figure: Connection of lux sensors
I © Vestamatic GmbH
NOTE! No connection possible for lux sensors 5 to 8 for version M 2C Wired.
- 17 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Terminals Up to 8 lux sensors can be connected at the control box to the terminals Sun 1 and 5V, Sun 2 and 5V and so on up to Sun 8 and 5V. The polarity of the lux sensors is not important for connection.
Information for the installer – Control box
Assembly / Connection of rain sensors Operation The rain sensor records both moisture on the sensor surface and decreases in outside temperature to below +1 °C or -20 °C. Its sensitivity can be set electronically. The measured precipitation is transformed into electrical digital signals. These are evaluated by the control system, which triggers the corresponding control commands. The sensor surface is heated for faster drying. This significantly reduces the time until the “rain end” message and, if necessary, the sunshading devices can be re-extended immediately.
Rain sensor +1 °C, article-no. 010830 If the outside temperature lies between approx. +1 °C and +30 °C and rain is detected, the sensor surface will be heated to aid drying. In the case of higher temperatures or frost, there will be no heating. If the temperatures are below +1 °C, frost will be recorded and the connected systems will be retracted or closed and manual operation will be blocked.
Assembly of rain sensor +1 °C or rain sensor -20 °C The rain sensor can be easily installed onto the aluminium mounting bracket article-no. 01100510 using the angled mounting bracket supplied. Use clips, cable ties or similar fasteners to attach the measuring cable securely to the mounting bracket so that the cable cannot be damaged by flapping and fraying during high winds.
Choice of assembly location The rain sensor should be mounted using the supplied bracket such that the surface of the sensor is directed towards the weather side. It should be angled at around 15 degrees so that large water droplets run off quickly and the sensor’s rain signal is quickly reset following a shower.
Maintenance / Cleaning If the device is subject to extreme weather conditions, it may only be assembled at angle of around 15 degrees, otherwise water could penetrate the device over a long period of time and impair its function. If the device is installed properly, it will work maintenance-free. If the rain sensor becomes excessively soiled, it can be cleaned with standard household cleaning products as long as they do not contain any aggressive or abrasive ingredients.
Cable lengths The signal cable can be extended up to 100 m with a cross section of 0.8 mm2.
© Vestamatic GmbH
- 18 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Rain sensor -20 °C, article-no. 010825 If the outside temperature lies between approx. +1 °C and +30 °C and rain is detected, the sensor surface will be heated to aid drying. In the case of higher temperatures, there will be no heating; if the outside temperature is between approx. -20 °C and approx. +1 °C, the sensor surface will be heated continuously. The connected systems will remain operational even in the case of temperatures down to -20 °C (if no rain).
Information for the installer – Control box Terminals Signal
Terminals control box
1
+12V
12V
2
GND
GND
3
Sensitivity I
Rainsense 1
4
Sensitivity II
Rainsense 2
5
Frost signal
Frost
6
Rain signal
Rain
Personal notices
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Terminals rain sensor
Figure: Connection of rain sensors
© Vestamatic GmbH
- 19 -
Subject to modifications!
Information for the installer – Control box
Assembly / Connection of temperature sensors TS Pro XL operation The temperature sensor TS Pro XL is used to record indoor or outdoor ambient temperature. Measured temperature within the range -30 °C to +55 °C is transformed into electrical analogue signals. These are evaluated by the control system, which triggers the corresponding control commands.
Assembly of temperature sensor TS Pro XL The temperature sensor can be installed using the supplied mounting clip. When installing on a mounting bracket, use clips, cable ties or similar fasteners to attach the measuring cable securely to the bracket so that the cable cannot be damaged by flapping and fraying during high winds.
TE Indoor The room temperature controller TE Indoor is used to record indoor temperature. A temperature threshold can be set within the range +5 °C to +30 °C using the adjusting knob.
Assembly of temperature sensor TE Indoor The room temperature controller may be used indoors and is suitable for surface mounting or for mounting directly onto a flush mounting box with vertical fixing holes.
Assembly of temperature sensor TE Outdoor The frost/temperature monitor is suitable for surface mounting out-of-doors with the cable inlet pointing downwards.
Choice of assembly location When mounting temperature sensors, avoid placing in direct sunlight as this will influence the measured value.
Maintenance / Cleaning The devices work maintenance-free. If the sensors (not TE Indoor) become excessively soiled, they can be cleaned with standard household cleaning products as long as these do not contain any aggressive or abrasive ingredients.
Cable lengths If the 5 m signal cable is too short, it can be extended up to 100 m using the same cross section.
© Vestamatic GmbH
- 20 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
TE Outdoor The frost/temperature monitor TE Outdoor is used to record outdoor temperature. A temperature threshold can be set within the range -20 °C to +35 °C using the adjusting knob.
Information for the installer – Control box
Figure: Connection of TS Pro XL
Figure: Connection of TE Indoor / TE Outdoor
Assembly / Connection of DCF radio-controlled clock receiver Operation The DCF Receiver picks up the time signal from the transmitter located in Mainflingen near Frankfurt. This long-wave transmitter has an average range of 1500 km. Once received, the signal is decoded and the control's internal clock is updated, resulting in a high degree of accuracy.
Choice of assembly location The DCF Receiver must be mounted outdoors with the cable inlet at the bottom. Aligning the radiocontrolled receiver with Frankfurt will additionally enhance the signal reception quality.
Maintenance / Cleaning The DCF Receiver works maintenance-free. If the sensor becomes excessively soiled, it can be cleaned with standard household cleaning products as long as they do not contain any aggressive or abrasive ingredients.
© Vestamatic GmbH
- 21 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Terminals The temperature sensor TS Pro XL is connected at the control box to the terminals TS 01 and +12V. The temperature sensor TE Indoor / TE Outdoor is connected via the internal terminals 1 and 2 to the terminals thermostat and GND at the control box. The polarity of the temperature sensor is not important for connection.
Information for the installer – Control box Cable lengths The signal cable can be extended up to 50 m with a cross section of 0.34 mm2.
Terminals Terminals DCF Receiver
Signal
Terminals control box
1
GND
GND
2
+12V
+12V
4
Neg. Logik
DCF
Personal notices
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Figure: Wiring diagram for DCF radio-controlled clock receiver
Terminals
Figure: Connection of DCF Receiver
© Vestamatic GmbH
- 22 -
Subject to modifications!
Information for the installer – Control box
Connection of buttons for external operation of channel groups Operation Every channel group has its own up/down input at the control box. These inputs require a floating button or switch so that several channel groups can be operated at the same time. Connect the button/switch to the desired input and to the corresponding terminal at the control box.
Cable lengths The maximum cable length when using cable JY ST (Y) 2 × 2 × 0.8 is 100 m.
Figure: Connection of external button
I
© Vestamatic GmbH
NOTE! No connection possible for button of external operation 3 and 4 for version M 2C Wired.
- 23 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Terminals Connect the button for external operation to the required input and to one of the GND terminals.
Information for the installer – Control box
Connection the maintenance switch Operation Using the maintenance input at the control box, your shading device can be moved to its upper or lower position and locked. This is extremely important when carrying out cleaning or maintenance work. All façades can be driven simultaneously into a fully open or closed position by using the maintenance switch. This makes it impossible for the façades to be operated locally using a local button.
Cable lengths The maximum cable length when using cable JY ST (Y) 2 × 2 × 0.8 is 100 m.
Figure: Connection of Maintenance
Ä
WARNING! In the event of a fire and/or wind alarm, all sunshade devices will be retracted immediately. Risk to life due to sudden movement of connected sunshades, mechanisms or skylights! Therefore: Before carrying out maintenance work on connected devices that are in an extended position, you must switch off those devices or switch off the control box.
© Vestamatic GmbH
- 24 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Terminals Connect the maintenance switch to the terminals Main down, Main up and GND.
Information for the installer – Control box
Connecting the control system to a smoke/fire alarm system Operation The control system can be connected to a smoke/fire alarm system using the FIRE input at the control box. In the event of an alarm, all sunshade devices will be immediately retracted and skylights will be closed. These devices will then be locked in their positions. This makes it impossible for the façades to be operated locally by using a local button. The FIRE input connection is made via a floating NC contact from the smoke/fire alarm centre. If the control box is not connected to a smoke/fire alarm centre, a wire bridge must be positioned at the fire input between the terminals FIRE and GND.
Cable lengths The maximum cable length when using cable JY ST (Y) 2 × 2 × 0.8 is 100 m.
Figur: Connection of smoke/fire alarm system
I
© Vestamatic GmbH
NOTE! A wire bridge is only used when the control system is not connected to a smoke/fire alarm centre.
- 25 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Terminals
Information for the installer – Control box
Connecting the display box to the control box via 4-wire interface Operation The 4-wire interface supplies power to the display box and also acts as a means of data exchange. This requires the display box to be connected to the control box.
Cable lengths The maximum cable length when using cable JY ST (Y) 2 × 2 × 0.8 is 100 m.
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Terminals
Figure: Connection of display box
Ä
© Vestamatic GmbH
ATTENTION! Check correct connection before starting up the device! Incorrect connection can destroy the device.
- 26 -
Subject to modifications!
Information for the installer – Control box
Display box installation Handling of mounting plate for attachment of display box Unplug the pre-punched cable gland in the mounting plate (see Figure 1, red shaded area) using a screwdriver and feed the connecting wires of the 4-wire interface through it (see Figure 2). Then attach the mounting plate accordingly. Figure: 1
© Vestamatic GmbH
- 27 -
Figure: 3
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Connecting the display box – Remove the 6 screws on the back of the display box housing. – Remove the rear of the housing. – Using a screwdriver, unplug the pre-punched cable gland (see Figure 3, red shaded area). – Feed through the 4-wire interface cable and connect in accordance with the wiring diagram (see page 26). – Replace the rear of the housing and screw it down using the 6 screws. – The display box can then be mounted in the mounting plate.
Figure: 2
Subject to modifications!
Information for the installer – Installation assistant (Wizard)
Quick reference guide
1. Password input
2. Wizard start
3. Setting the user interface language, to other languages p. 2–3
4. Communication mode recognition
5. Scanning connected sensor devices
6. Manual activation of the rain and/or temperature sensor
7. Type selection of the particular channel group, page 1
8. Type selection of the particular channel group, page 2
9. Sensor selection of lux sensors
10. Lux sensor assignment, page 1, sensors 1 to 4
11. Lux sensor assignment, page 2, sensors 5 to 8
12. Sensor selection of wind sensors
13. Wind sensor assignment, wind threshold and wind sensor setting
14. Wind sensor type setting: WM1 or WM2
15. Sensor selection of temperature sensors
16. Temperature sensor assignment, display box internal temperature sensor, TE Indoor, TE Outdoor or TS Pro XL
Sensor selection of connected wind sensors
Sensor selection of connected temperature sensors
Repeat settings for channel groups to , following points 9 to 21, depending on connection.
Sensor selection of connected rain sensors
17. Rain sensor activation
18. Activating the device locking function © Vestamatic GmbH
19. Security query for activating the device locking function
20. Setting the number of days until the device locks
- 28 -
21. Option of setting safety position – Wizard end Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Sensor selection of connected lux sensors
Information for the installer – Installation assistant (Wizard)
General notes The installation assistant (wizard) will help you to implementing the control system. It will guide you through the installation program step-by-step where you will configure the channel group outputs, façade outputs and the connected sensor devices. Main buttons and their function Button
for the next menu.
Button
for the previous menu.
Button
for the next page of the current menu.
Settings Password input Enter your 4-digit security code in order to access the installation program. Use the buttons and to correct the number and press buttons and to go to the next digit. Once you have entered the security code, press the next menu.
to go to
Ä
WARNING! For security reasons you will find the 4-digit security code on the invoice for the control system. The security code is ONLY intended for use by professional installers and may not be passed on to end users as this will enable end users to turn off safety-related settings. This may cause serious personal injury or damage to property!
Wizard start Press Start to bring up the wizard (Installation assistant). The menu “Setting the user interface language” (Install) appears.
Setting the user interface language (Install) Use this menu to set the language to be displayed on the user interface. The language selection is confirmed with a green tick. For the choice of other languages: Button for the next pages (2 + 3) of the current menu. to go to the next menu “Communication mode Press recognition”.
© Vestamatic GmbH
- 29 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
The “Wizard start” menu appears.
Information for the installer – Installation assistant (Wizard)
Communication mode recognition Communication mode recognition (Install) In this menu the connection between the control box and display box is displayed. = = = = = =
connection via 4-wire interface radio connection (without function) no connection low signal strength sufficient signal strength good signal strength
Press
to return to the language setting menu.
Press to go to the next menu to scan the connected sensor devices.
= Thermostat TE Indoor or TE Outdoor = Rain sensor RD +1°C or RD -20°C
I
See note below.
Press
to return to the communication mode recognition menu.
Press
for the next menu “Type select”.
NOTE! The rain sensor and the thermostat are not recognised automatically. If these sensors are installed, each sensor must be activated manually. To do this, touch the appropriate symbol so that the symbol appears over the appropriate sensor.
© Vestamatic GmbH
- 30 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Scanning connected sensor devices In this menu all the connected and operational sensors are checked and displayed. = Lux sensor LS 30 = Wind sensor WM1 or WM2 = Temperature sensor internal and/or TS Pro XL = DCF radio-controlled clock receiver
Information for the installer – Installation assistant (Wizard) Selection of connected channel group In this menu, you can assign a particular control system type as well as sensors and settings to each channel group. The following control system types are available: Page 1 = awning = blind = skylight = roller shutter
to go to page 2 of the current menu. to go to the menu on scanning the connected sensor devices.
Press Press Press
I Page 2
= ventilation = heating = Not connected, no function not connected to this channel group
for the next menu “Sensor Select”. NOTE! The channel group you are currently setting is shown in the top right of the display, e.g. for channel group 1. If you have selected a function for a channel group you will be automatically directed to the next menu to assign the sensors. Here the available sensors are assigned to the respective channel group. When sensor assignment is complete, you will be taken automatically to the type selection of the next channel group, e.g. for channel group 2.
Selection of sensors from connected sensor devices Possible sensor assignment, depending on type selection: Control system type
Examples
© Vestamatic GmbH
possible sensor assignment
= awning
sun, wind, temperature, rain
= blind
sun, wind, temperature, rain
= skylight
wind, temperature, rain
= roller shutter
sun, temperature
= lighting
no sensor assignment possible
= ventilation
temperature
= heating
temperature
= no function / not connected to this channel group
no sensor assignment possible
- 31 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Page 1
Page 2 = lighting
Information for the installer – Installation assistant (Wizard)
I
NOTE! The symbol appears if no corresponding sensor has been assigned. As soon as the corresponding sensor is activated, the symbol appears, marking the sensor concerned. This feature is not available for the type selection and . Lux sensor assignment This menu enables you to assign one or more lux sensors to the particular channel group. Click the appropriate lux sensor to activate it. The symbol is displayed over the appropriate sensor to confirm its activation. Press Press Press
to go to page 2 of the current menu. to return to the menu on the sensor selection of connected sensor devices. for the next menu.
Ä
WARNING! For safety reasons, you may ONLY activate the wind sensor and select the corresponding wind sensor types from this menu. For the same reasons, both wind sensors are enabled in the default settings. If one of the wind sensors is not connected to the Touch Centre, or neither of them is connected, the corresponding wind sensor must be explicitly disabled in the “Wind sensor assignment” menu. See also connection examples p. 16 “Connection without wind sensor”. It is not permitted to have different types of wind sensors or other manufacturers’ wind sensors connected at the same time. This may cause serious personal injury or damage to property. Wind sensor assignment This menu enables you to assign one or more wind sensors to the particular channel group. Click the appropriate wind sensor to activate/deactivate it. The symbol is displayed over the appropriate sensor to confirm its activation. Use the buttons and to set the wind threshold in km/h or m/s. Press
for the previous menu, Press
for the next menu.
Wind sensor type setting In this menu you can set the wind sensor type to be used. The following wind sensor types can be set using the buttons and . Type WM1 = WS XS, Art.-no. 01100310 Type WM1 = WS XS Alu, Art.-no. 01100410 Art.-no. 01100235 Type WM2 = WS Classic M,
© Vestamatic GmbH
Press
for the previous menu.
Press
to return to the menu “Sensor Select”. - 32 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Page 1 = Lux sensor selection 1 to 4 Page 2 = Lux sensor selection 5 to 8
Information for the installer – Installation assistant (Wizard)
I
NOTE! A connected temperature or rain sensor must be manually activated in advance. See also page 30 “Scanning connected sensor devices”.
Temperature sensor assignment This menu enables you to assign the internal temperature sensor in the display box, the thermostat connected at the control box, or the temperature sensor TS Pro XL to the particular channel group. Click the appropriate sensor to activate is displayed over the appropriate sensor to it. The symbol confirm its activation. Only one of the three sensors can be assigned in each case.
Press
for the previous menu.
Press
for the next menu.
Rain sensor assignment This menu enables you to assign the rain sensor to the particular channel group. Click the rain sensor to activate it. The symbol is displayed over the rain sensor to confirm its activation. Press
for the previous menu.
Press
for the next menu.
Activating the device lock function In this menu you can activate the device lock function whereby the device is locked for the user after a set number of days has elapsed. After the correct 4-digit unlock code has been entered, the device will be unlocked and can be used again. By clicking the button followed by , you come to the next menu which asks you to confirm that you really wish to activate the device lock function. By clicking the button followed by , the device lock function will be disabled and you will go straight to the “Wizard Finish” menu. Press
for the previous menu.
… please see also next page.
© Vestamatic GmbH
- 33 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
internal temperature sensor in the display box thermostat connected at the control box TE Indoor / TE Outdoor temperature sensor TS Pro XL connected at the control box
Example
Information for the installer – Installation assistant (Wizard)
By clicking the button followed by , you are confirming activation of the device lock function and come to the next menu in which the number of days can be set for the device to be locked. Press
for the previous menu.
Press
for the next menu.
The required number of days for the device to be locked can be and buttons. set using the for the previous menu.
Press
for the next menu.
WARNING! You can find the 4-digit security code on the invoice for the control system. The unlock code is ONLY intended for use by professional installers and is not communicated to end users.
Wizard end Once all the channel groups have been configured, press to move all sunshades to their upper end positions and to close all skylights so that a function check of the system can be performed. This retract/close command remains active until the wizard symbol. finishes and is represented by a flashing
Ä
Press
for the previous menu.
Press
to finish configuring the control system.
WARNING! Before you move the devices into the safety position, ensure that no assembly, maintenance or repair work is still being carried out on the devices. Risk to life and property due to sudden movement of connected sunshades, mechanisms or skylights! Press
© Vestamatic GmbH
to close the wizard.
- 34 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Ä
Press
Information for the user – General notes
General notes The Touch Centre is a microprocessor-controlled central control for different products such as blinds, awnings, shutters, skylights, ventilation systems, heating and lighting. The connected sunshade, lighting, ventilation or heating systems are centrally controlled according to sun intensity, wind speed, precipitation and time. All settings, safety-related changes, fault reports and alarm signals are stored electronically in the logbook. General notes on touchscreen displays
I
NOTE! Please note that the touchscreen is extremely sensitive. Pressing the screen too hard, scratching it or using a sharp object will cause irreparable damage to the screen. Therefore, do not use a pointed or sharp object to touch the screen. Only clean the display using special cleaning wipes or a soft glasses cloth. The display can be locked when cleaning (see section Lock display, page 36).
Operating modes and control While in automatic operation mode, the connected products will be operated fully automatically, depending on wind, sun, rain, temperature, time and fire alarm. While in manual operation mode, all safety functions will continue to operate. Only sun, temperature and time-dependent controls are switched off in this mode.
Manual control Before a channel group can be changed from automatic control to manual control, the channel group . Press must first be activated. Touch the group to activate it. An active group is shown by the symbol the auto symbol to change the group to manual control. This is indicated by the hand symbol in the top right-hand corner of the display.
Display of operation mode
Display of operation mode
“Automatic control“
“Manual control“
Manual control of sunshades/skylights Press up Press down
to retract sunshades/open skylights. to extend sunshades/close skylights.
To stop the sunshade/skylight while it is moving, simply press the opposite button. Manual control of lighting/heating/ventilation Lighting, heating or ventilation
Press
to switch on,
Button
means switched on.
Lighting, heating or ventilation
Press
to switch off,
Button
means switched off.
© Vestamatic GmbH
- 35 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
The individual channel groups, the operating mode of the selected group as well as the date and time are shown clearly on the display. Similarly, sensor information and status messages relating to the individual channel groups can also be queried.
Information for the user – General notes Automatic control Before a channel group can be changed from manual control to automatic control, the channel group must first be activated. Touch the group to activate it. An active group is shown by the symbol . Press the symbol to change the group to automatic control. This is indicated by the auto symbol in the top right-hand corner of the display.
I
NOTE! While in automatic mode it is still possible to control the channel group manually using the up / down or on / off buttons. If manual operations are carried out while in automatic mode, automatic operation will be disabled until the next control cycle.
Information for the user – Weather info / Display lock / Comfort program
By pressing the button you can call up weather information from the assigned sensors. The highest value of each sensor group will be shown. This means that if several lux sensors are assigned in a channel group, the value of the sensor with the highest sun intensity level will be displayed. Also shown is the last retract/extend command carried out for the selected channel group. Examples
Press
to return to the main screen.
Example sensor values for channel group 1: Wind speed: 18 km/h Sun intensity: 6 kLux Temperature: 25 °C
Lock / Unlock display The display can be locked for cleaning or to prevent unauthorised access. Press button for 3 seconds to lock the display. The symbol will appear, indicating that the display is for locked. To unlock the display, press and hold button 3 seconds. Example
© Vestamatic GmbH
- 36 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Weather info / Status indication
Information for the user – Weather info / Display lock / Comfort program Comfort program for setting scenarios The comfort program gives you the option of creating 4 different scenarios which can be activated manually as and when required via the 4 scenario buttons. All channels can be programmed and controlled differently for each of the 4 scenarios. Press and hold for 3 seconds to call up the comfort program menu. You are then able to choose one of the four comfort programs to . The comfort program that is selected is symbol. represented by a flashing To create or adjust your own settings for one of the comfort to programs, press and hold the appropriate button from for 3 seconds. You can now set the runtime and, if required, a tilting time for that channel group. Use buttons and to set the runtime and tilting time.
I
Press
for the previous menu.
Press
to return to the user menu.
NOTE! A retract or skylight close command is always performed before a comfort program is carried out. After this command has been completed the devices will move to the set position for that particular comfort program.
© Vestamatic GmbH
- 37 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
A green tick appears (e.g. ) to indicate that a particular comfort program has been configured.
Information for the user – Basic settings
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Quick reference guide
© Vestamatic GmbH
- 38 -
Subject to modifications!
Information for the user – Basic settings detail 1/3 User menu Press button to go from the user menu to the basic settings which are divided into 3 pages (Detail 1/3, Detail 2/3 and Detail 3/3).
I
NOTES! – The times and values used in the following displays in this user guide are provided as examples. Only the symbols, arrows, texts and the warning information correspond to the actual display. – The control will automatically return to the user menu 2 minutes after the last entry is made in the basic settings menu. All changes made will be automatically saved. Basic settings detail 1/3 On this page you can set the time, change the display colour setting, activate the display’s standby time or configure the system release following a fire alarm.
Basic settings page 1
= Release following fire alarm = to page 2 of the basic settings or back to page 1. Press
to return to the user menu.
Setting the time / date Set your current time zone here using the “GMT” (Greenwich and . Mean Time) button and the Press
to set the year.
Press
to set the month.
Press
to set the day.
Press
to set automatic summer/winter time changeover.
The symbol indicates the active function. Press for the previous menu.
I
NOTE! The clock is internally powered by a buffer battery which means that the date and time are saved even if there is a power failure. If a DCF Receiver is connected and there is sufficient clock signal, the time and date will be set automatically.
© Vestamatic GmbH
- 39 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
= Settings for time, year, month, day, automatic summer/winter time changeover = Setting the display colour selection = Setting the display standby time
Information for the user – Basic settings detail 1/3 Setting the display colour selection Use buttons , , and to choose between the three different display background colours. indicates the active function. The symbol Press for the previous menu. Press
to return to basic settings page 1.
Setting the display standby time and to set a standby time of between 1 and Use buttons 15 minutes. Press
for the previous menu.
Press
to return to basic settings page 1.
Once the set time has elapsed the display will switch off. Press anywhere on the touchscreen to switch the display back on.
Ä
WARNING! This menu is password-protected for security reasons. You will find the 4-digit security code on the invoice for the control system! The security code is ONLY intended for use by professional installers and may not be passed on to end users as this will enable end users to turn off safety-related settings. This may cause serious personal injury or damage to!
This menu is password-protected and may only be accessed by the installer. Here you can program how the control system will behave when the fire alarm is reset by the fire alarm system.
I
Press
for automatic release of the control system following a fire alarm.
Press
to require user confirmation before releasing the control system following a fire alarm.
Press
for the previous menu.
Press
to return to basic settings page 1.
NOTE! A fire alarm results in the immediate retraction of sunshades and closure of skylights. Connected ventilators and/or heating units are also switched off immediately.
© Vestamatic GmbH
- 40 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Release following fire alarm
Information for the user – Basic settings detail 2/3 Basic settings detail 2/3 On this page you can program the LAN connection, display the logbook, view contact information or query the software version of the display and control box.
Basic settings, page 2
= = = =
network settings (without function) display logbook display contact information display software version and serial number
= to page 3 of the basic settings or back to page 1 Press
to return to the user menu.
Block 1, page 1
I
Press
to go to blocks 2 to 4.
Press
for the previous menu.
Press
to return to page 2 of the basic settings.
NOTE! After the network settings have been changed, the control box is reset. This results in the connected systems receiving a close command.
Display logbook The control system’s logbook records all sensor-related fault reports and alarm signals. Safety-related changes are also stored. Use buttons and to view the various logbook entries.
I
Press
for the previous menu.
Press
to return to page 2 of the basic settings.
NOTE! The logbook may only be deleted by the manufacturer. All entries are stored electronically and will not be lost even in the event of a power failure or if the control box’s battery is removed.
© Vestamatic GmbH
- 41 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Network settings (without function) In this menu you can set the IP address for the network connection. The 4 blocks of 3-digit numbers can be entered one after the other. Use buttons and to alter the IP block data.
Information for the user – Basic settings detail 3/3 Display contact details On this page you will find details of how to contact the manufacturer. Press
for the previous menu.
Press
to return to page 2 of the basic settings.
Press
for the previous menu.
Press
to return to page 2 of the basic settings.
Basic settings detail 3/3 On this page you can retract the connected sunshades to their upper end positions, close the skylight, recalibrate the touch display, restart the wizard, or restore the control’s factory settings.
Basic settings, page 3
= = = = = Press
move to safety position calibrate touchscreen start wizard restore factory settings to page 1 of the basic settings. to return to the user menu.
Move to safety position
Ä
WARNING! Before you move the devices into the safety position, ensure that no assembly, maintenance or repair work is being carried out on the devices. Risk to life and property due to sudden movement of connected sunshades, mechanisms or skylights!
to retract all sunshades to their upper end positions Press and/or to close the skylight.
© Vestamatic GmbH
- 42 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Display software version and serial number On this page you will find information relating to the software version and serial number of the control system.
Information for the user – Basic settings detail 3/3 Touchscreen calibration The accuracy of the touchscreen can change after a long period of use, making recalibration necessary. to start the recalibration and follow the instructions on Press the display. The process will involve touching a flashing point in the top left and then in the bottom right of the screen. If calibration is successful, you are then able to exit the menu by pressing the button . If calibration is not successful, you will need to touch the flashing points again.
Display/Start wizard
You can use the wizard button to adjust the installation settings. For example, you can add a motor type to a free channel group or extend a channel group by adding additional sensors. After you have pressed the button you will be requested to enter a security code. You will not be able to make any changes without entering a security code.
© Vestamatic GmbH
- 43 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Ä
WARNING! This menu is password-protected for security reasons. You will find the 4-digit security code on the invoice for the control system! The security code is ONLY intended for use by professional installers and may not be passed on to end users as this will enable end users to turn off safety-related settings. This may cause serious personal injury or damage to!
Information for the user – Basic settings detail 3/3 Restore factory settings
Ä
WARNING! This menu is password-protected for security reasons. You will find the 4-digit security code on the invoice for the control system! The security code is ONLY intended for use by professional installers and may not be passed on to end users as this will enable end users to turn off safety-related settings. This may cause serious personal injury or damage to!
Security code 4668:
Only personal settings such as thresholds or delay times will be deleted and the factory settings reloaded.
Security code XXXX:
Please refer to the invoice for the security code. This code will delete all settings and assignments. The control system will be reset to the default setting and must then be reconfigured.
you will be requested to After you have pressed the button enter a security code. You will not be able to make any changes without entering a security code. See details of the password input menu on page 29.
© Vestamatic GmbH
- 44 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
the control system can be reset to By pressing the button the following operating states, depending on the security code:
Information for the user – Fine adjustments User menu
Quick reference guide
Press and hold the button for the desired channel group for 3 sec. in order to make fine adjustments to that function.
Detail 1/5
Sun function Extension sun threshold Extension response time Retract time delay Retract sun threshold Sun motor runtime Number of sundependent extension commands per day
Detail 2/5
Detail 3/5
MC DZ M/J function
Motor run time Motor run time
Tilting function
Inching mode function
1. Tilting time „Season“ Tilting time spring … Tilting time winter Tilting assignment
Detail 4/5
UP time function
Detail 5/5
Heating function
Monday UP Monday duration …
Temperature threshold Anti-freeze
Sunday UP Sunday duration
Reset delay Temperature unit
2. Tilting time „Table“ Tilting time January (Time 1 bis 4) …
Rain function
Password input Reset delay Sensitivity setting Manual extension when rain/frost
Continuous up command Continuous down command
Holiday function
Astro function
Ventilation function Temperature threshold Reset delay Temperature unit
Automatic mode lock
Password input Wind threshold 1 Wind threshold 2 Response delay Reset delay Wind unit
Monday OFF Monday duration … Sunday OFF Sunday duration Handheld transmitter
Temperature function Temperature threshold 1 Temperature threshold 2 Runtime for temperature threshold 2 Reset delay Temperature unit
© Vestamatic GmbH
Monday DOWN Monday duration …
Astro setting Longitude LON Sunday DOWN Latitude LAT Sunday duration Up time correction Down time correction
Wind function
DOWN time function
Programming / Deleting (without function)
- 45 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Tilting time December (Time 1 bis 4) Tilting assignment
Information for the user – Fine adjustments detail 1/5 The fine adjustments allow you to set individual values for each channel group. For example, you can program different thresholds and delay times, set tilting times for each shade type, and give fixed drive times. The fine adjustments menu comprises 5 pages. If you need to make fine adjustments to a channel group, press and hold the field for the channel group for 3 seconds. If a menu with the symbol appears, then this function cannot be activated or programmed. User menu Press and hold the button for the desired channel group (e.g. awning) for 3 seconds in order to make fine adjustments to that channel.
Fine adjustments detail 1/5 On this page you can perform fine adjustments to the following functions:
Page 1
= = = = = Press
© Vestamatic GmbH
sun function rain function wind function temperature function to page 2 of the fine adjustments or back to page 1. to return to the user menu.
- 46 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
I
NOTES! – The times and values used in the displays that illustrate this user guide are merely provided as examples. Only the symbols, arrows, texts and the warning information correspond to the actual display. – 2 minutes after the last entry is made in the fine adjustments menu, the control will automatically return to the user menu. All changes made will be automatically saved.
Information for the user – Fine adjustments detail 1/5 Sun function The sun function automatically controls the connected sunshade in relation to the sun intensity. Function may only be activated for the following control types = awnings = roller shutters = blinds
Setting extension sun threshold In this menu, the threshold value at which the sunshade will be extended is set in klux (1000 lux). The current measured sun intensity will also be displayed in the bottom left of the screen. The threshold value can be set separately using the and buttons: Programmable range: off, 16 – 100 kLux Press to return to the detail 1/5 menu. for the extension resonse time menu.
Setting extension response time The extension response time delays the extension of the sunshade after the set threshold for the extension has been exceeded. A response time can be set (in minutes) using the and buttons. Programmable range: 1 – 60 minutes Press to return to the extension sun threshold menu. Press
for the retract time delay menu.
Setting retract time delay The retract time delay delays the retraction of the sunshade after the sun intensity has fallen below the set threshold for retraction. A reset time can be set (in minutes) using the and buttons. Programmable range: 1 – 60 minutes Press
to return to the extension response time menu.
Press
for the retract sun threshold menu.
Setting retract sun threshold In this menu, the threshold value at which the sunshade will be extended is set in klux. The current measured sun intensity will also be displayed in the bottom left of the screen. The threshold value can be set separately using the and buttons. Programmable range: 10 – 99 kLux
© Vestamatic GmbH
Press
to return to the retract time delay menu.
Press
for the sun motor runtime menu.
- 47 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Press
Information for the user – Fine adjustments detail 1/5 Setting sun motor runtime In this menu, you can set the motor runtime which starts when the connected sunshade receives a sun command. The runtime can be set (in seconds) using the and buttons. Programmable range: 3 – 180 seconds Press
to return to the retract sun threshold menu.
Press
for the menu for setting the number of sun-dependent extension commands per day.
I
Press
to return to the sun motor runtime menu.
Press
to go to the detail 1/5.
NOTE! If the number of sun-dependent extension commands has been restricted and this limit has been reached, an automatic sun retract command will no longer occur. The devices must then be retracted manually or via a time command.
Rain function The rain function protects the connected sunshade from rain. Function may only be activated for the following control types = awnings = skylights = blinds
Ä
WARNING! This menu is password-protected for security reasons. You will find the 4-digit security code on the invoice for the control system! The security code is ONLY intended for use by professional installers and may not be passed on to end users as this will enable end users to turn off safety-related settings. This may cause serious personal injury or damage to property!
See details of the password input menu on page 29.
© Vestamatic GmbH
- 48 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Setting number of sun-dependent extension commands per day In this menu, you can set how often the connected sunshades are extended when the sun function's extension threshold is exceeded. A limit of between 1 and 10 extensions per day can be set using the and buttons. Unlimited means no limitation of sun-dependent extension commands per day. Programmable range: Unlimited, 1 – 10
Information for the user – Fine adjustments detail 1/5 Setting rain reset delay The rain reset delay will only begin once the rain sensor stops sending a rain/frost signal to the control. When this delay time has elapsed, the connected device will again be controlled automatically by the sensors or preset times. The rain reset delay can be set separately using the and buttons. Programmable range: 1 – 60 minutes Press
to return to the detail 1/5 menu.
Press
for the rain sensitivity setting menu.
Setting rain sensitivity setting In this menu, you can set the sensitivity of the rain sensor. You have four options: = = = =
high sensitivity normal sensitivity moderate sensitivity no sensitivity
Press
to return to the rain reset delay menu.
Press
for the manual extension when rain/frost menu.
Setting manual extension when rain/frost In this menu, you can set whether manual operation of the connected devices is permitted in the case of rain or frost. If this is required, press the appropriate symbol. The symbol will then appear by .
© Vestamatic GmbH
Press
to return to the rain sensitivity setting menu.
Press
to go to the detail 1/5.
- 49 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
To set the sensitivity, press the appropriate symbol. The symbol will then appear by the appropriate sensitivity level.
Information for the user – Fine adjustments detail 1/5 Wind function The wind function protects the connected devices from extreme wind conditions. Function may only be activated for the following control types = awnings
Ä
= skylights
= blinds
WARNING! This menu is password-protected for security reasons. You will find the 4-digit security code on the invoice for the control system! The security code is ONLY intended for use by professional installers and may not be passed on to end users as this will enable end users to turn off safety-related settings. This may cause serious personal injury or damage to property!
Setting wind threshold 1 In this menu, you can set a wind threshold which, if exceeded, will immediately result in the retraction of the connected sunshade or the closure of the skylight. Setting the wind threshold value depends on the sunshade’s or skylight’s size and design. The sunshade cannot be extended again until the time delay has expired. Use the buttons and to set the wind threshold. Programmable range: 10 – 100 km/h Press
to return to the detail 1/5 menu.
Press
for the wind threshold 2 menu.
Setting wind threshold 2 In this menu, you can set a wind threshold which, if exceeded and the time delay has expired, will immediately result in the retraction of the connected sunshade or the closure of the skylight. Setting the wind threshold value depends on the sunshade’s or skylight’s size and design. The sunshade cannot be extended again until the time delay has expired. Use the buttons and to set the wind threshold. Programmable range: off, 10 – 99 km/h.
I
Press
to return to the wind threshold 1 menu.
Press
for the wind response delay menu.
NOTE! Wind threshold 2 cannot be set higher than wind threshold 1.
© Vestamatic GmbH
- 50 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
See details of the password input menu on page 29.
Information for the user – Fine adjustments detail 1/5 Setting wind response delay The wind response delay allows you to program a delay time (in seconds). The connected sunshades will not retract, or the skylight will not close, unless this time has expired and wind threshold 2 continues to be exceeded. Programmable range: off, 1 – 60 seconds.
I
Press
to return to the wind threshold 2 menu.
Press
for the wind reset delay menu.
NOTE! If wind threshold 2 is set to off, this menu is not visible.
Setting wind reset delay The wind reset delay allows you to program a delay time (in minutes). Only when the wind speed has dropped below the thresholds and this delay time has elapsed, will the connected sunshade or the skylight again be controlled automatically by the sensors or preset times. Press
to return to the wind response delay menu.
Press
for the wind unit menu.
Setting wind unit In this menu, you have the option of displaying the wind speed in km/h or m/s. To set the wind unit, press the appropriate symbol. The symbol will then appear by the selected unit.
© Vestamatic GmbH
Press
to return to the wind reset delay menu.
Press
to go to the detail 1/5.
- 51 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Programmable range: 1 – 60 minutes.
Information for the user – Fine adjustments detail 1/5 Temperature function In the case of the temperature function, if the set temperature threshold is exceeded the sunshade will be extended or the skylight will open. If the particular channel group is also controlled via the sun function, then both the sun threshold and the temperature threshold must be exceeded to result in the sunshade extending or the skylight opening. If the readings are below the set thresholds, no extension or opening will take place. If the sunshade is already extended or the skylight already open and one of the readings drops below the threshold, this will result in retraction/closure after the delay time has elapsed. Function may only be activated for the following control types = awnings = blinds = roller shutters = skylights
Setting temperature threshold 1 In this menu, you can set a temperature threshold which, if exceeded, will immediately result in the extension of the connected sunshade or the opening of the skylight. Use the buttons and to set the desired temperature threshold. The current measured temperature will also be shown in the bottom left of the display. Programmable range: off, 15 °C – 35 °C to return to the detail 1/5 menu. Press Press
for the temperature threshold 2 menu.
Setting temperature threshold 2
I
NOTES! – This function is only for skylights with analogue temperature sensor. If threshold 1 is set to off, this menu is not visible. – Temperature threshold 2 cannot be set higher than temperature threshold 1.
In this menu, you can set a temperature threshold which, if exceeded, will immediately result in the opening of the skylight. It is also possible to program a temperature threshold 2 with a separate motor runtime (see Runtime for temperature threshold 2, p. 53), to realize partly opening of skylight. Use the buttons and to set the desired temperature threshold. Programmable range: off, 15 °C – 34 °C to return to the temperature threshold 1 menu. Press Press
© Vestamatic GmbH
for the runtime for temperature threshold 2 menu.
- 52 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
I
NOTE! In case of TE Indoor and TE Outdoor assignment, display of actual temperature is not possible. Following temperature settings are disabled.
Information for the user – Fine adjustments detail 1/5 Setting runtime for temperature threshold 2
I
NOTE! This function is only possible for assignment of skylights with analogue temperature sensors TS Pro XL or display box. If threshold 1 is set to off, this menu is not visible.
In this menu, an additional motor runtime is set which is enabled when temperature threshold 2 is exceeded. Buttons can be used to adjust the number of seconds that the and motor runs so that the skylight partly opens. Programmable range: off, 1 – 120 seconds Press
to return to the temperature threshold 2 menu.
Press
for the temperature reset delay menu.
Setting temperature reset delay
The reset delay delays sunshade retraction or skylight closure after the temperature drops below the set threshold. A reset delay can be set (in minutes) using the and buttons. Programmable range: 1 – 60 minutes Press
to return to the runtime for temperature threshold 2 menu.
Press
for the temperature unit menu.
Setting temperature unit
I
NOTE! This function is only possible for assignment with analogue temperature sensors TS Pro XL or display box. If threshold 1 is set to off, this menu is not visible.
In this menu, you have the option of displaying the temperature unit in degrees Celsius (°C), kelvin (K) or Fahrenheit (F). To set the temperature unit, press the appropriate symbol. The symbol will then appear by the selected unit.
© Vestamatic GmbH
Press
to return to the temperature reset delay menu.
Press
to go to the detail 1/5.
- 53 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
I
NOTE! This function is only possible for assignment with analogue temperature sensors TS Pro XL or display box. If threshold 1 is set to off, this menu is not visible.
Information for the user – Fine adjustments detail 2/5
Page 2
Fine adjustments detail 2/5 On this page you can perform fine adjustments to the following functions: = motor runtime, general = tilting function, general = continuous up command = continuous down command = to page 3 of the fine adjustments or back to page 1. to return to the user menu.
Press
Motor run time NOTE! If the MC DZ M/J function is activated, it will not be possible to program the motor runtime, tilting and inching mode functions. In that case, these functions will be marked with a grey .
I
Function may only be activated for the following control types = awnings = blinds = roller shutters = skylights Programmable range for shutters/skylights: 3 – 120 seconds Programmable range for awning/blinds: 3 – 180 seconds or
Press
to return to the detail 2/5 menu.
Tilting function In this menu, you can set a tilting time. It is depending on the selected tilting types Tilting time “Season” or Tilting time “Table” and the related functions. Setting each tilting time depends on the size and construction of the sunshade. The time can be adjusted in increments of 100 ms. At the end of the motor runtime, the sunshade moves in the opposite direction (retracts) to enable the slats to be positioned to the correct angle. The tilt function is performed in both automatic and manual operation mode, depending on setting.
© Vestamatic GmbH
- 54 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
In this menu, you can set a general motor runtime for extension or opening. By operating buttons and the desired motor run time can be set in seconds.
Information for the user – Fine adjustments detail 2/5 Tilting function continued from p. 54.
Function may only be activated for the following control types: = roller shutters = blinds = awnings Programmable range: off, 0,1 – 10 seconds Press
to go to the menu “Selection of tilting type”.
Selection of tilting type Button “Season” Activating tilting type “Tilting time by season” Button “Table” Activating tilting type “Tilting time by table” Press
to go to the menu „Detail 2/5“
button to Depending on the activated tilting type, press the continue to the “Set tilting time according to season” or “Set tilting time according to table” menu.
Tilting type “Season”:
Tilting type “Table”:
Setting tilting time “Season”
Setting tilting time “Table”
Spring Summer Autumn Winter
Press the button to return to the previous “Set tilting time for the individual seasons” menu or to go to the “Detail 2/5” menu.
© Vestamatic GmbH
January (Time 1) January (Time 2) January (Time 3) January (Time 4) …
December (Time 1) December (Time 2) December (Time 3) December (Time 4)
The tilting time can be set for the respective month within a time frame.
A separate tilting time can be set for each season (spring, summer, autumn and winter). Tilting can be set to off if this function is not required. Press to copy the previous page’s setting and press again to paste.
button to go to the “Set tilting time Press the for the individual seasons” or the “Set tilting assignment” menu.
In this menu, for each month, four daily recurring time frames can be set using the and buttons. The default setting is 8am, 11am, 2pm and 5pm. This means that in the time frame between 8am and 11am, a different tilting time can be set than in the time frame between 11am and 2pm. During the period of time between time 4 and time 1, the tilting time from time 4 will continue until time 1 is activated again.
- 55 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
I
NOTE! Only one tilting type can be activated per channel.
Information for the user – Fine adjustments detail 2/5
Tilting type “Season”:
Tilting type “Table”:
To continue with “Set tilting assignment”, see the next menu option.
Continued from the previous page: Press the button go to the next time in the month or to the 1st time in the following month. button to go to the previous time Press the in the month or to the 4th time in the previous month. button to return to the previous Press the “Tilting time for the respective time” or to go to the “Select tilting type” menu. Press the button to go to the "Tilting time for the respective time" menu. Setting the tilting time for the respective time
Press the button to copy over the tilting time setting (time) from the previous page. button to return to the previous Press the time in the month. Press the button to go to the next time in the month or to the 1st time in the following month, or to go to the “Set tilting assignment” menu. Setting tilting assignment Here the tilting function is assigned to the individual functions. If tilting assignment is active, the symbol appears beside that function. = tilting related to performance of sun function = tilting related to performance of temperature function = tilting related to performance of manual operation = tilting related to performance of time command Press
I
or
to return to the detail 2/5 menu.
NOTE! If the sun and temperature function is assigned to a channel group, the tilting function will automatically be selected/deselected when triggered by sun and temperature.
© Vestamatic GmbH
- 56 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
In this menu, a tilting time for the respective time can be set using the buttons and .
Information for the user – Fine adjustments detail 2/5 Continuous up command If this function is active ( ), then an up command will be given for the duration that the group button is pressed. Press the to activate the function. If the function is inactive, symbol an up command will be given according to the preset motor run time after operation of group command. Continuous down command If this function is active ( ), then a down command will be given for the duration that the group button is pressed. If the function is inactive, an down command will be given according to the preset motor run time after operation of group command.
I
NOTE! By pressing the group button no operation via display is possible.
= to page 3 of the fine adjustments or back to page 1. to return to the user menu.
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Press
© Vestamatic GmbH
- 57 -
Subject to modifications!
Information for the user – Fine adjustments detail 3/5 Fine adjustments detail 3/5 On this page you can perform fine adjustments to the following functions: = MC DZ M/J function = inching mode function = holiday function = astro function = to page 4 of the fine adjustments or back to page 1. Page 3 Press
to return to the user menu.
MC DZ M/J function
Function may only be activated for the following control types = awnings = roller shutters = blinds
The MC DZ M/J function is used exclusively for controlling the decentralised controls MC DZ M/J, MC P1, MC P2 and MC P4 in operating modes 4, 5 and 6. Before this function can be activated you must first enter a 4-digit security code. See details of the password input menu on page 29.
I
NOTE! When the MC DZ M/J function is active, it will switch off all motor runtimes and tilting times for that channel group. The runtimes and tilting times need to be set on the decentralised controls MC DZ M/J, MC P1, MC P2 and MC P4.
Inching mode function If this function has been activated ( ), an inching mode of up to 2 seconds is enabled. This means that the runtime command is not executed for 2 seconds. Press the symbol to activate the function. Function may only be activated for the following control types = blinds
© Vestamatic GmbH
- 58 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Ä
WARNING! This menu is password-protected for security reasons. You will find the 4-digit security code on the invoice for the control system! The security code is ONLY intended for use by professional installers and may not be passed on to end users as this will enable end users to turn off safetyrelated settings. This may cause serious personal injury or damage to property!
Information for the user – Fine adjustments detail 3/5 Holiday function The holiday function produces a ‘random time’. This means that the connected sunshade goes up or down with a deviation of up to +/- 15 minutes from the programmed times and Astro times. This ‘irregular’ raising and lowering of the sunshade will give the impression that the house is occupied and offers extra security when you are absent for long periods. Press the symbol to activate the holiday function. The symbol indicates that the holiday function is active. Function may only be activated for the following control types = blinds = roller shutters = lighting
Astro function The Astro function is an electronic calendar. Depending on the sunrise and sunset times, the up/down times will be automatically adjusted according to your residence’s geographical location. In addition, these times will be compared with the programmed up/down times. To use the Astro function you will need to enter the coordinates of your place of residence (see page 60).
I
Notes on Astro function – If the up time you have programmed occurs earlier than the morning Astro time, the sunshade will go up at the Astro time. – If the up time you have programmed occurs later than the morning Astro time, the sunshade will go up at the programmed up time. – If the down time you have programmed occurs later than the evening Astro time, the sunshade will go down at the Astro time. – If the down time you have programmed occurs earlier than the evening Astro time, the sunshade will go down at the programmed down time. The Astro function can be switched off for any day of the week by setting the time function to off.
Astro setting Further adjustments can only be made when the Astro function is active ( ). Press the symbol
© Vestamatic GmbH
to activate the Astro function.
Press
to return to the detail 3/5 menu.
Press
for the longitude LON menu.
- 59 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Function may only be activated for the following control types = blinds = roller shutters = lighting
Information for the user – Fine adjustments detail 3/5
I
Information for adjustment of degrees of latitude and longitude! We have listed a number of cities and their longitudes and latitudes on page 67 of the operating instructions.
Setting longitude LON In this menu you are able to enter the longitude of your place of residence. Use buttons and to enter the longitude in ° and minutes. Press
to return to the astro setting menu.
Press
for the latitude LAT menu.
Press
to return to the longitude LON menu.
Press
for the up time correction menu.
Setting up time correction If you are not happy with the Astro times stored in the calendar for sunrise, you can correct the time set for performing the up commands by +/- 59 minutes with the buttons and . Press
to return to the latitude LAT menu.
Press
for the down time correction menu.
Setting down time correction If you are not happy with the Astro times stored in the calendar for sunset, you can correct the time set for performing the down commands by +/- 59 minutes with the buttons and .
© Vestamatic GmbH
Press
to return to the up time correction menu.
Press
to go to the detail 4/5.
- 60 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Setting latitude LAT In this menu you are able to enter the latitude of your place of residence.
Information for the user – Fine adjustments detail 4/5 Fine adjustments detail 4/5 On this page you can perform fine adjustments to the following functions: = UP time function = Down time function = automatic mode lock = programming/deleting handheld transmitter (without function) = to page 5 of the fine adjustments or back to page 1.
Page 4
Press
to return to the user menu.
… Monday up
Monday duration
Sunday up
Sunday duration
Function may only be activated for the following control types = awning = lighting = blind = skylight = roller shutter
= ventilation = heating
Press
to copy over the previous page's setting (day of the week).
Press
to return to the previous day in the menu (Monday to Sunday) or to return to detail 4/5.
Press
to go to the next day in the menu (Monday to Sunday) or to return to detail 4/5.
© Vestamatic GmbH
- 61 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
UP time function Using the UP time function it is possible to retract the selected channel group or the connected sunshade at a certain time, to close the skylight, or to switch on lighting, ventilation or heating. An individual up time/close time/switch-on time can be programmed for each day of the week. Use buttons and to adjust these times. In the next menu you also have the option of setting the duration of the retract command or the switch-on period.
Information for the user – Fine adjustments detail 4/5 DOWN time function Using the DOWN time function it is possible to extend the selected channel group or the connected sunshade at a certain time, or to open a skylight. A separate extend time/open time can be programmed for each day of the week. Use buttons and to adjust these times. In the next menu you also have the option of setting the duration of the extend/open command.
… Monday duration
Sunday down
Sunday duration
Function may only be activated for the following control types = awnings = blinds = roller shutters
= skylights
Press
to copy over the previous page's setting (day of the week).
Press
to return to the previous day in the menu (Monday to Sunday) or to return to detail 4/5.
Press
to go to the next day in the menu (Monday to Sunday) or to return to detail 4/5. Automatic mode lock In this menu, you can program a time slot for each day of the week during which time automatic control will be switched off. This means that no automatic retract/extend commands or open/close commands (triggered by the sun and/or the temperature) will be performed during the selected period. To activate this function, set the start time of the particular day using the buttons and . Press to set the period of the automatic lock and press again to set the next day of the week.
… Monday off
Monday duration
Sunday off
Function may only be activated for the following control types = awnings = blinds = roller shutters = skylights
Sunday duration
= ventilation
= heating
Press
to copy over the previous page's setting (day of the week).
Press
to return to the previous day in the menu (Monday to Sunday) or to return to detail 4/5.
Press
to go to the next day in the menu (Monday to Sunday) or to return to detail 4/5.
© Vestamatic GmbH
- 62 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Monday down
Information for the user – Fine adjustments detail 4/5 Programming/deleting handheld transmitter In this menu, you can program or delete the optional handheld transmitter. To teach in the transmitter, press the button (green arrow). While the LED is flashing, press the button of the transmitter you wish to program. To delete a transmitter, press the button (red arrow). While the LED is flashing, press the button of the transmitter you wish to delete. Function can be activated for all control types. Press
or
to return to the detail 4/5 menu.
Information for the user – Fine adjustments detail 5/5
Example user menu
= Heating function = Ventilation function = to page 1 of the fine adjustments detail 1/5. Press
to return to the user menu.
Page 5
Heating function The heating function automatically switches on the connected heater when the temperature drops below a certain threshold. The connected heating system can additionally be switched on when the temperature drops below additional threshold as an protection against frost. Function may only be activated for the heating type of control system.
© Vestamatic GmbH
- 63 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Fine adjustments detail 5/5 On this page you can perform fine adjustments to the following functions:
Information for the user – Fine adjustments detail 5/5 Setting temperature threshold In this menu, you can set a temperature threshold. If the temperature drops below this level the connected heating will be switched on and if the threshold is exceeded the heating will be switched off again automatically once the delay time has elapsed. Programmable range: off, 15°C – 35°C
Use the buttons threshold.
and
to set the desired temperature
Press
to return to the detail 5/5 menu.
Press
for the anti-freeze menu.
Setting anti-freeze In this menu, you can set a temperature threshold. If the temperature drops below this level the connected heating will be switched on and if the threshold is exceeded the heating will be switched off again automatically once the delay time has elapsed. Programmable range: off, 3°C – 10°C Use the buttons and to set the desired temperature threshold. Press
to return to the temperature threshold menu.
Press
for the reset delay menu.
Setting reset delay The reset delay function delays the switching off time of the heating after exceeding the preset temperature threshold programmed in temperature threshold and anti-freeze menu. A reset delay can be set (in minutes) using the and buttons. Press
to return to the anti-freeze menu.
Press
for the temperature unit menu.
Setting temperature unit In this menu, you have the option of displaying the temperature unit in degrees Celsius (°C), kelvin (K) or Fahrenheit (F). To set the temperature unit, press the appropriate symbol. The symbol will then appear by the selected unit.
© Vestamatic GmbH
Press
to return to the reset delay menu.
Press
for the detail 5/5 menu.
- 64 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
I
NOTE! In case of TE Indoor and TE Outdoor assignment, display of temperature is not possible. Following temperature settings are disabled.
Information for the user – Fine adjustments detail 5/5 Ventilation function The ventilation function will switch on the connected ventilation if the set temperature threshold is exceeded. Function may only be activated for the ventilation type of control system.
Setting temperature threshold In this menu, you can set a temperature threshold. If the temperature exceeds this level the connected ventilation will be and to set the desired switched on. Use the buttons temperature threshold. Programmable range: off, 15°C – 35°C
Press
to return to the detail 5/5 menu.
Press
for the temperature unit menu.
Setting reset delay The reset delay delays the switching off of the ventilation after the temperature drops below the set threshold. A reset delay can be set (in minutes) using the and buttons. Programmable range: 1 – 60 minutes Press to return to the temperature threshold menu. Press
for the temperature unit.
Setting temperature unit In this menu, you have the option of displaying the temperature unit in degrees Celsius (°C), kelvin (K) or Fahrenheit (F). To set the temperature unit, press the appropriate symbol. The symbol will then appear by the selected unit.
© Vestamatic GmbH
Press
to return to the reset delay menu.
Press
for the detail 5/5 menu.
- 65 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
I
NOTE! In case of TE Indoor and TE Outdoor assignment, display of temperature is not possible. Following temperature settings are disabled.
Information for the user – Control system warning signals Fire alarm (alert) A fire alarm that has been triggered will be displayed as shown in the adjacent image. If the manual reset option has been selected for the fire alarm, the fire alarm must be reset both at the fire alarm centre and on the display. If the automatic reset option has been selected, the fire alarm will automatically reset itself after resetting at the fire alarm centre.
Wind sensor cable rupture If the wind sensor connection cable is damaged, this fault will be indicated on the display. The display will then change to show the sensor error with details of that sensor. The sunshade controlled by the defective sensor will then retract immediately and will remain in the retracted position until the fault is repaired. This will happen automatically.
The warning signals may be reset with button again
but after one hour they will be displayed
48 h wind sensor alarm If the externally mounted wind sensors do not send any signal for a period of 48 hours, this will be indicated on the display. This warns you that you need to check the wind sensor(s). In this case, test that the wind vanes are turning smoothly by pushing them by hand. If, after this test, the display does not change, you cannot be guaranteed safe use of the sunshade. We recommend that you turn off the control system and ensure that it cannot be operated unintentionally Lux sensor cable rupture If the lux sensor connection cable is damaged, this fault will be indicated on the display. The display will then change to show the sensor error with details of that sensor.
Temperature sensor cable rupture If the connection cable for the temperature sensor TS Pro XL is damaged, this fault will be indicated on the display. The display will then change to show the sensor error with details of that sensor.
© Vestamatic GmbH
- 66 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
I
NOTE FOR FOLLOWING WARNING SIGNALS!
City Salzburg Tyrol Vienna Brussels Bern Zürich Prague Aachen Berlin Bonn Bremen Cologne Cottbus Dortmund Dresden Duisburg Düsseldorf Frankfurt a. M. Hamburg Hanover Innsbruck Kaiserslautern Karlsruhe Kassel Kiel Leipzig Mainz Mannheim Munich Münster Nuremberg Regensburg Stuttgart Ulm Würzburg Copenhagen Barcelona Madrid Dijon Marseille Paris Helsinki Kuopio Tampere Birmingham London Manchester Milan Naples Rome Dublin Luxemburg Oslo Trondheim Amsterdam Eindhoven Rotterdam Moscow Gothenburg Stockholm
© Vestamatic GmbH
Country
Longitude LON °: min
Latitude LAT °: min
A A A B CH CH CZ D D D D D D D D D D D D D D D D D D D D D D D D D D D D DK E E F F F FIN FIN FIN GB GB GB I I I IRL L N N NL NL NL RUS S S
13°02 11°20 16°23 04°21 07°26 08°33 14°25 06°05 13°24 07°05 08°48 06°57 14°19 07°27 13°44 06°45 06°46 08°41 10°00 09°43 11°23 07°46 08°24 09°29 10°08 12°22 08°16 08°28 11°34 07°37 11°05 12°06 09°11 09°59 09°55 12°34 02°09 - 03°42 05°01 05°24 02°20 24°56 27°41 23°45 - 01°55 - 00°07 - 02°14 09°11 14°15 12°29 - 06°14 06°08 10°44 10°25 04°53 05°28 04°28 37°36 11°58 18°03
47°48 47°15 48°13 50°50 46°56 47°22 50°05 50°46 52°31 50°43 53°04 50°56 51°45 51°31 51°03 51°26 51°13 50°07 53°33 52°22 47°15 49°26 49°00 51°19 54°19 51°20 49°59 49°29 48°08 51°57 49°25 49°00 48°46 48°23 49°47 55°40 41°23 40°24 47°19 43°18 48°52 60°10 62°54 61°30 52°28 51°30 53°28 45°27 40°50 41°54 53°19 49°37 59°54 63°25 52°22 51°26 51°55 55°45 57°42 59°19
- 67 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Information for the user – List of cities for the Astro function
Information for the user – Symbol description Symbols general Function enabled
Function cannot be enabled
Function disabled
Back to previous menu
Settings menu
Automatic lock active
I
Note / information
UP: retract sunshade / open skylight
DOWN: extend sunshade / close window
Back to previous menu
Copy function
ON: switch on lighting, heating or ventilation
OFF: switch off lighting, heating or ventilation
Switched on lighting, heating or ventilation
Switched off lighting, heating or ventilation
Device lock function activated
Device unlocked
Plus / increase setting value
Minus / decrease setting value
Manufacturer logo
© Vestamatic GmbH
Automatic mode
Manual operation
Channel group one
Channel group two
Channel group three
Channel group four
Control system type: awning
Control system type: lighting
Control system type: blind
Control system type: ventilation
Control system type: skylight
Control system type: heating
Control system type: shutter
Not connected, not connected to this channel group
- 68 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Caution / warning
Information for the user – Symbol description
Wizard
Go to next menu
Password input
Language German
Language English
Language Norwegian
Language Swedish
Language Nederlands
Language French
Language Hungarian
Language Czech
Language Polish
Language Romanian
In progress
Communication via 4-wire interface
Radio communication (without function)
No connection
Low signal strength
Sufficient signal strength
Good signal strength
Sensor selection: lux sensor LS 30
Sensor assignment: lux sensors 1 to 8
Sensor selection: wind sensors 1 or 2
Sensor assignment: wind sensors 1 and 2
Sensor selection general
Sensor assignment: temperature sensor TS Pro XL
Sensor selection: display box temperature sensor
Sensor assignment: temperature sensors TE Indoor or TE Outdoor
Rain sensor activation RD +1 °C or RD -20 °C
DCF radio-controlled clock receiver
Move to safety position
© Vestamatic GmbH
- 69 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Installation assistent (Wizard) symbols
Information for the user – Symbol description Info & comfort menu symbols Weather info / status indication
To return to user menu
Lock / unlock display
Display lock
Comfort buttons
Comfort buttons 1 to 4
Info on retract comfort setting
Info on extend comfort setting
Info on retract following fire alarm
Info on retract anti-freeze
Info on retract manual function
Info on extend manual function
Info on retract sun function
Info on extend sun function
Info on retract temperature function
Info on extend temperature function
Above set temperature
Below set temperature
Info on retract clock function
Info on extend clock function
Info on retract wind function Info on retract maintenance function
Info on extend maintenance function
Info move to safety position
© Vestamatic GmbH
- 70 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Info on retract rain function
Information for the user – Symbol description Basic settings symbols To return to user menu Time / date
Display colour selection
Display background colour 1
Display background colour 2
Display background colour 3
Display standby time
Release following fire alarm Automatic release following fire alarm
Network settings (without function)
Display logbook
Display manufacturer contact
Display software version
Move to safety position
Touchscreen calibration
Display/start wizard
Restore factory settings
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Manual release following fire alarm
© Vestamatic GmbH
- 71 -
Subject to modifications!
Information for the user – Symbol description
To return to user menu
Sun function
Rain function
Rain sensitivity: high sensitivity
Rain sensitivity: normal sensitivity
Rain sensitivity: moderate sensitivity
Rain sensitivity: no sensitivity
Manual extension when rain/frost
Anti-freeze function
Wind function
Wind speed display in km/h
Wind speed display in m/s
Temperature function
Temperature in Celsius
Temperature in Fahrenheit
Temperature in Kelvin
Motor runtime setting
Tilting function
Jump forward to the next time in the tilting table.
Jump back to the previous time in the tilting table.
Tilting performance related to sun function
Tilting performance related to temperature function
Tilting performance related to manual function
Tilting performance related to time function
Continuous up command
Continuous down command
MC DZ M/J function
Inching mode function
Holiday function
Astro function
Retract / skylight open time function
Extend / skylight close time function
Automatic mode setting
Programming/Deleting handheld transmitter (without function))
Teach in handheld transmitter (without function)
Delete handheld transmitter (without function))
Heating function
Ventilation function
© Vestamatic GmbH
- 72 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Fine adjustments symbols
Information for the user – Manufacturer’s default settings
Ä
WARNING! The default basic settings must, in certain cases, be adapted to the connected products according to manufacturers’ instructions.
F Function enabled Function cannot be enabled Settings
Awnings
Blinds
Shutters
Extension sun threshold
20 kLux
25 kLux
20 kLux
Extension response time
2 min.
2 min.
2 min.
Skylights
Lighting
Heating
Ventilation
Sun function
Retract time delay
15 min.
15 min.
15 min.
Retract sun threshold
15 kLux
20 kLux
15 kLux
3 min.
3 min.
2 min.
unlimited
unlimited
unlimited
Reset delay
2 min.
2 min.
2 min.
Sensitivity setting
normal
normal
normal
OFF
OFF
OFF
Wind threshold 1
30 km/h
30 km/h
40 km/h
Wind threshold 2
OFF
OFF
OFF
Response delay
OFF
OFF
OFF
15 min.
15 min.
15 min.
km/h
km/h
km/h
21°
21°
Sun motor runtime Number of sun-dependent extension commands per day Rain function
Manual extension when rain/frost
Reset delay Wind unit
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Wind function
Temperature function Temperature threshold 1
21°
OFF
Temperature threshold 2
10 sec.
Runtime for temperature threshold 2 Reset delay Temperature unit
23°
5 min.
5 min.
5 min.
5 min.
°C
°C
°C
°C
3 min.
3 min.
2 min.
2 min.
Motor run time Setting Tilting function 1. Tilting time “Season”
OFF
OFF
OFF
Tilting time Spring
OFF
OFF
OFF
Tilting time Sommer
OFF
OFF
OFF
Tilting time Autumn
OFF
OFF
OFF
Tilting time Spring
OFF
OFF
OFF
2. Tilting time “Table”
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Tilting time January, Time 1 (8.00 a.m.) Tilting time January, Time 2 (11.00 a.m.) Tilting time January, Time 3 (2.00 p.m.) Tilting time January, Time 4 (5.00 p.m.)
© Vestamatic GmbH
- 73 -
Subject to modifications!
Information for the user – Manufacturer’s default settings Settings
Awnings
Blinds
Shutters
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Sun
ON
ON
ON
Temperature
ON
ON
ON
Manual operation
ON
ON
ON
Time
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Continuation 2. tilting time by table … Tilting time December, Time 1 (8.00 a.m.) Tilting time December, Time 2 (11.00 a.m.) Tilting time December, Time 3 (2.00 p.m.) Tilting time December, Time 4 (5.00 p.m.) Tilting assignment by
Skylights
Lighting
Heating
Ventilation
Continuous up command Setting Continuous down command Setting MC DZ M/J function Setting Inching mode function ON (2 sec.)
Setting
Setting
OFF
OFF
OFF
OFF
OFF
OFF
Astro function Setting
6.27
6.27
6.27
Latitude LAT
51.12
51.12
51.12
Up time correction
0 min.
0 min.
0 min.
Down time correction
0 min.
0 min.
0 min.
Longitude LON
UP time function lighting / ventilation / heating ON Monday
OFF
OFF
8:00
OFF
OFF
OFF
OFF
Duration
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Tuesday
OFF
OFF
8:00
OFF
OFF
OFF
OFF
Duration
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Wednesday
OFF
OFF
8:00
OFF
OFF
OFF
OFF
Duration
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Thursday
OFF
OFF
8:00
OFF
OFF
OFF
OFF
Duration
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Friday
OFF
OFF
8:00
OFF
OFF
OFF
OFF
Duration
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Saturday
OFF
OFF
8:00
OFF
OFF
OFF
OFF
Duration
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Sunday
OFF
OFF
8:00
OFF
OFF
OFF
OFF
Duration
OFF
OFF
OFF
OFF
OFF
OFF
OFF
© Vestamatic GmbH
- 74 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Holiday function
Information for the user – Manufacturer’s default settings Settings
Awnings
Blinds
Shutters
Skylights
Lighting
Heating
Ventilation
Monday
OFF
OFF
20:00
OFF
Duration
OFF
OFF
OFF
OFF
Tuesday
OFF
OFF
20:00
OFF
Duration
OFF
OFF
OFF
OFF
Wednesday
OFF
OFF
20:00
OFF
Duration
OFF
OFF
OFF
OFF
Thursday
OFF
OFF
20:00
OFF
Duration
OFF
OFF
OFF
OFF
Friday
OFF
OFF
20:00
OFF
Duration
OFF
OFF
OFF
OFF
Saturday
OFF
OFF
20:00
OFF
Duration
OFF
OFF
OFF
OFF
Sunday
OFF
OFF
20:00
OFF
Duration
OFF
OFF
OFF
OFF
Monday
OFF
OFF
20:00
Duration
OFF
OFF
12 h
OFF
OFF
OFF
OFF
OFF
OFF
Tuesday
OFF
OFF
20:00
OFF
OFF
OFF
Duration
OFF
OFF
12 h
OFF
OFF
OFF
Wednesday
OFF
OFF
20:00
OFF
OFF
OFF
Duration
OFF
OFF
12 h
OFF
OFF
OFF
Thursday
OFF
OFF
20:00
OFF
OFF
OFF
Duration
OFF
OFF
12 h
OFF
OFF
OFF
Friday
OFF
OFF
20:00
OFF
OFF
OFF
Duration
OFF
OFF
12 h
OFF
OFF
OFF
Saturday
OFF
OFF
20:00
OFF
OFF
OFF
Duration
OFF
OFF
12 h
OFF
OFF
OFF
Sunday
OFF
OFF
20:00
OFF
OFF
OFF
Duration
OFF
OFF
12 h
OFF
OFF
AUS
DOWN time function lighting / ventilation / heating OFF
Heating function 20 °C
Temperature threshold Anti-freeze
5 °C
Reset delay
10 min. °C
Temperature unit Ventilation function 23°
Temperature threshold
10 min.
Reset delay
°C
Temperature unit Fire function Setting
© Vestamatic GmbH
with confirmation
with confirmation
with with confirmation confirmation
- 75 -
with with confirmation confirmation
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Automatic mode lock
Information for the user – Personal settings Settings
Awnings
Blinds
Shutters
Skylights
Lighting
Heating
Ventilation
Sun function Extension sun threshold Extension response time Retract time delay Retract sun threshold Sun motor runtime Number of sun-dependent extension commands per day Rain function Reset delay Sensitivity setting Manual extension when rain/frost Wind function Wind threshold 1 Wind threshold 2 Response delay Reset delay Wind unit
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Temperature function Temperature threshold 1 Temperature threshold 2 Runtime for temperature threshold 2 Reset delay Temperature unit Motor run time Setting Tilting function Tilting time spring Tilting time summer Tilting time autumn Tilting time winter Tilting assignment in relation to Sun Temperature Manual operation Time
© Vestamatic GmbH
- 76 -
Subject to modifications!
Information for the user – Personal settings Settings
Awnings
Blinds
Shutters
Skylights
Lighting
Heating
Ventilation
Continuous up command Setting Continuous down command Setting MC DZ M/J function Setting Inching mode function Setting Holiday function Setting Astro function Setting Longitude LON Latitude LAT Up time correction Down time correction UP time function lighting / ventilation / heating ON Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Monday Duration Tuesday Duration Wednesday Duration Thursday Duration Friday Duration Saturday Duration Sunday Duration DOWN time function lighting / ventilation / heating OFF Monday Duration Tuesday Duration © Vestamatic GmbH
- 77 -
Subject to modifications!
Information for the user – Personal settings Settings
Awnings
Blinds
Shutters
Skylights
Lighting
Heating
Ventilation
Wednesday Duration Thursday Duration Friday Duration Saturday Duration Sunday Duration Automatic mode lock Monday Duration Tuesday Duration Wednesday Duration
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Thursday Duration Friday Duration Saturday Duration Sunday Duration Heating function Temperature threshold Anti-freeze Reset delay Temperature unit Ventilation function Temperature threshold Reset delay Temperature unit Fire function Setting
© Vestamatic GmbH
- 78 -
Subject to modifications!
Error
Cause of Error
Troubleshooting
Control system does not function
Power failure Fault in the connection area of the control system
Wait until power supply is restored Check 160 mA T fine-wire fuse and replace if necessary Check connection according to wiring diagram (see p. 10)
Connected motors do not move in or out, skylights do not open or close
Fine-wire fuse in the motor box is faulty No wire bridge between Common and L1 (only in the case of direct motor connection!)
Check 6.3 A T fine-wire fuse and replace if necessary Check wire bridge between Common and L1 (see p. 13)
No display box display
Fault in the connection of the 4-wire interface
Check connection according to wiring diagram (see p. 10) See p. 26
Display turns off after short period
Standby time set to 1 minute
Adjust standby time to required level (see p. 40)
No or insufficient radio-controlled clock reception
Signal strength is too low
Check connection according to wiring diagram (see p. 22) Change the mounting position of the DCF 77 radio-controlled clock receiver (see p. 22)
48 h wind sensor alarm display
Wind sensor blocked No wind over the last 48 hours
Check the affected wind sensor (see p. 66)
Wind sensor cable rupture display
Wind sensor’s connecting cable damaged Fault in connection area
Check connection according to wiring diagram (see p. 10) Check connecting cable for damage (see p. 66)
Lux sensor cable rupture display
Lux sensor’s connecting cable damaged Fault in connection area
Check connection according to wiring diagram (see p. 10) Check connecting cable for damage (see p. 66)
Wind speed display too low
Wind sensor is not positioned fully in the area of wind flow Incorrect wind sensor type is set
Check the wind sensor position and change if necessary (see p. 15) Check the smooth running of the wind wheel (see p. 66) Check settings in the wizard (see p. 32)
Lux sensor displays readings that are too low
Lux sensor is in the shade Lux sensor is soiled or covered
Check the lux sensor position and change if necessary (see p. 17) Remove any soiling (see p. 17)
© Vestamatic GmbH
- 79 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Information for the user – Troubleshooting
Information for the user – Troubleshooting Error
Cause of Error
Troubleshooting
Lux sensor displays readings that are too high
Lux sensor is affected by reflected light Strong lighting in the vicinity of the lux sensor
Check the lux sensor position and change if necessary (see p. 17)
The sunshade has travelled to its upper end position and can no longer be controlled manually
No automatic movement of sunshade in response to sun, temperature or time commands
Sun/temperature thresholds set too high No time commands programmed Control system is in manual mode
Adjustment of the appropriate thresholds (see p. 47 or 52) Program time control (see pp. 61–62) Select automatic mode (see p. 36)
No retraction during strong winds
Wind threshold set too high
Adjust the wind threshold according to the instructions of the sunshade manufacturer (see p. 50)
When in manual mode, the blinds do not tilt and move directly into their upper end position
Inching mode for that channel group is switched off
Select channel group and switch on inching mode under fine adjustments (see p. 58)
During sunshine, shade moves into its lower end position too late
Incorrect lux sensor selected Lux sensor is soiled Lux sensor is shaded Extend sun threshold setting is too high Response time setting is too long Automatic lock is active
Change lux sensor assignment (see p. 32) Clean lux sensor (see p. 17) Change the lux sensor position (see p. 17) Decrease threshold for extend sun function (see p. 47) Decrease sun function response time (see p. 47) Switch off automatic lock or adjust start time and duration (see p. 62)
In cloudy conditions, shade moves into its upper end position too late
Threshold for retract sun function is set too high Response time setting is too long
© Vestamatic GmbH
Wind alarm active Rain/frost alarm active Maintenance switch active Fire alarm triggered, manual reset selected
- 80 -
Decrease threshold for extend sun function (see p. 47) Decrease sun function response time (see p. 47)
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Adjust the wind threshold according to the instructions of the sunshade manufacturer (see p. 50) Activate manual extension in case of rain rain/frost alarm (see p. 49) Fire alarm release selected (see p. 40)
Error
Cause of Error
Troubleshooting
In cloudy conditions, shade moves into its upper end position too early
Threshold for retract sun function is set too low Response time setting is too short
Raise threshold for retract sun function (see p. 47) Increase sun function response time (see p. 47)
Sunshade does not automatically move into its upper position in the evening
Retract threshold setting is too low Lux sensor is affected by strong light source Sunshade has been lowered manually
Raise threshold for retract sun function (see p. 47) Check the lux sensors’ readings (see p. 47) Retract the sunshade manually Check automatic lock (see p. 62)
Skylight opens too late
Temperature threshold setting for ‘open skylight’ is too high
Decrease threshold for temperature function (see p. 52)
Skylight only partially opens
Temperature threshold 2 for skylight has been exceeded
Decrease temperature threshold 1 for skylight function (see p. 52) Increase motor runtime for skylight function (see p. 53)
No automatic retraction of sunshade during rain when in manual mode
Rain/frost alarm not active in manual mode
Change rain/frost alarm setting for manual mode (see. p. 49)
Connected sunshades extend for only 3 seconds in response to sun / temperature
MC DZ M/J function is active Runtime is set to 3 seconds
Deactivate MC DZ M/J function (see p. 58) Adjust sunshade runtime (see pp. 48, 53 and 54)
© Vestamatic GmbH
- 81 -
Subject to modifications!
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Information for the user – Troubleshooting
Information for the user – Cleaning / Disposal of waste Touchscreen display maintenance and cleaning Note that the touchscreen display is a sensitive electronic component. An operation can be activated by lightly touching the screen. Pressing the screen too hard, scratching it or using a sharp object will cause irreparable damage to the screen or even render it unusable. Therefore, do not use a pointed or sharp object to touch the screen. Clean the display using a soft glasses cloth.
Maintenance and cleaning of control box and sensors If the device and sensors are installed properly, they will work maintenance-free. In the case of excessive soiling, the control box and sensors can be cleaned with standard household cleaning products as long as these do not contain any aggressive or abrasive ingredients.
The disposal of electrical equipment and batteries in household waste is strictly forbidden. The symbol (dustbin crossed out, in line with WEEE Appendix IV) indicates separate collection of electrical and electronic products in EU countries. Do not dispose of the device or battery in your household waste. Ask your town or local council about the return and collection systems available in your area to dispose of this product.
Art.-Nr.: 84500601 E1• Vestamatic GmbH • Dohrweg 27 • D-41066 Mönchengladbach • www.vestamatic.com
Information for the user – Customer service
Vestamatic GmbH Dohrweg 27 41066 Mönchengladbach / Germany Phone: +49 21 61 / 29 408-0 Fax: +49 21 61 / 29 408-20
[email protected] www.vestamatic.com
© Vestamatic GmbH
- 82 -
Subject to modifications!