Preview only show first 10 pages with watermark. For full document please download

Tpa/gmt Fuse Panel -/+24 To 48v Dc

   EMBED


Share

Transcript

DATA SHEET Part # 8272201001 SERVING THE COMMUNICATIONS INDUSTRY SINCE 1922 TPA/GMT Fuse Panel -/+24 to 48V DC Positions Per Bus 4 TPA - 10 GMT Max Per Position 50A TPA - 15A GMT Bus Capacity 250 Amps GENERAL CONNECTIONS Dimensions 19.00” W x 3.50” H x 12.125” D 2 Hole Lug 3/8’’ stud x 1’’ spacing Rack Space 2U Wire Range Up to 500 kcmil Weight 11.0 lbs. Max. Terminal Width 1.400” Mounting Universal 19” or 23”, WECO or EIA Tightening Torque 190 in-lb (21.5 Nm) Mtg. Pos. Flush, 3” or 4” Offset Barrier Strip Output Finish Black Textured Powder Coat TPA - #8 Sems Screw, GMT #6 Sems Screw Wire Range TPA - 6 to 22 AWG GMT 10 to 22 AWG Max. Terminal Width TPA - 0.500” / GMT - 0.312” Tightening Torque 10 in-lb GMT - 16 in-lb TPA 2 Hole Lug 1/4” stud x 1” spacing Wire Range 2 AWG lug supplied with panel Input Output ELECTRICAL Input Output Nominal Voltage -/+24-48V DC Voltage Range -/+19-60V DC Number of Buses 2 Intr. Device Rating 300 Amps Max Fuse Rating TPA Fuse - 50 Amp GMT Fuse - 15 Amp Continous Load Rating TPA Fuse - 40 Amps GMT Fuse - 10.5 Amps ALARMING Ground Bus ENVIRONMENT Short Term Op Temp -40° C to +70° C Ambient Up to 65° C Indicators Green (Power)/Red (Alarm) Store Temp -40° C to +70° C Function Form C relay contacts for remote fuse and power fail indication Humidity 0 to 95% non-condensing Conn. Type Solderless Wire Wrap (18 to 30 AWG) Power Dissipation 60.44 Watts max Rating DC 30W/AC 50VA STANDARDS Safety (Listed) Telcordia © 2015 Trimm, Inc. UL 60950-1/UL 1801/CSA C22.2 No.60950-1/EN 60950-1/IEC 60950-1 NEBS Level 3 (GR-63/GR-1089) and GR-3108 Class 3 (w/o salt fog testing) Revision 6/1/2015 407 Railroad St. • Butner, NC 27509 • Phone: 919-575-6100 • Toll Free: 800-298-7466 • Fax: 919-575-6200 • www.trimminc.com 10/4 GMT TPA Fuse Panel, Stud Input, Barrier Output, 2U 8272201001 INPUT CONNECTION (SHOWN WITH COVERS REMOVED) TPA OUTPUT CONNECTION (SHOWN WITHOUT COVER) REMOTE ALARM CONNECTION GMT OUTPUT CONNECTION (SHOWN WITHOUT COVER) INPUT SAFETY COVERS OUTPUT SAFETY COVER 12.152 [308.7] 3.125 [79.4] 4.125 [104.8] 10.000 [254.0] CHASSIS GROUND CONNECTION POWER/FUSE FAIL LED INDICATORS 2.000 [50.8] 3.484 [88.5] TPA TYPE FUSE HOLDERS 3.000 [76.2] GMT TYPE FUSE HOLDERS 17.000 [431.8] CIRCUIT DESIGNATION CARDS 18.312 [465.1] 19.000 [482.6] NOTES Go to www.trimminc.com for a complete list of the fuses to order with this panel. Revision 6/1/2015 407 Railroad St. • Butner, NC 27509 • Phone: 919-575-6100 • Toll Free: 800-298-7466 • Fax: 919-575-6200 • www.trimminc.com