Transcript
TPX-4 PCI-Expansion Subsystem Installation Manual Version 1.1—February 2003
Themis Computer—Americas and Pacific Rim 3185 Laurelview Court Fremont, CA 94538 Phone (510) 252-0870 Fax (510) 490-5529 World Wide Web http://www.themis.com
Themis Computer—Rest of World 5 Rue Irene Joliot-Curie 38320 Eybens, France Phone +33 476 14 77 80 Fax +33 476 14 77 89
Copyright © 2003 Themis Computer, Inc. ALL RIGHTS RESERVED. No part of this publication may be reproduced in any form, by photocopy, microfilm, retrieval system, or by any other means now known or hereafter invented without the prior written permission of Themis Computer. The information in this publication has been carefully checked and is believed to be accurate. However, Themis Computer assumes no responsibility for inaccuracies. Themis Computer retains the right to make changes to this publication at any time without prior notice. Themis Computer does not assume any liability arising from the application or use of this publication or the product(s) described herein. RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the United States Government is subject to the restrictions set forth in DFARS 252.227-7013 (c)(1)(ii) and FAR 52.227-19.
TRADEMARKS THEMIS® is a registered trademark of Themis Computer, Inc. SOLARIS™ is a trademark of Sun Microsystems SPARC® and UltraSPARC® are registered trademarks of SPARC International InfiniBand™ is a trademark and servicemark of the InfiniBand® Trade Association All other trademarks or registered trademarks used in this publication are the property of their respective owners.
Themis Customer Support North America, South America, and Pacific Rim Telephone: Fax: E-mail: Web Site:
510-252-0870 510-490-5529
[email protected] http://www.themis.com
TPX-4 PCI-Expansion Subsystem Installation Manual February 2003 Part Number: 110476-021
TPX-4 PCI-Expansion Subsystem Installation Manual
Version Revision History Version 1.1..................................................................................... February 2003 • Replaced photographs and illustrations of TPX-4 throughout manual to reflect changes from Version 1.0 model. • Revise weight specifications in Table 1-4 (Chapter 1). • Revised procedure for installing PCI Cards (Chapter 2). • Added Tables 2-1 and 2-2 with Figures to describe new InfiniBand jumper-pins on TPX-4 Interface board and host computer Bridge PCI card (Chapter 2). • Corrected Table A-1 and Table A-4 (Appendix A). • Made assorted minor revisions and corrections.
Version 1.0................................................................................... September 2002
Themis Computer
iii
TPX-4 PCI-Expansion Subsystem Installation Manual
iv
Themis Computer
Table of Contents 1. TPX-4 Overview, Specifications, & Agency Compliance .......................................... 1-1 1.1
Overview ................................................................................................................ 1-1 1.1.1 I/O Controls and System Indicators ........................................................... 1-3 1.1.2 Host InfiniBand Bridge PCI Card .............................................................. 1-6
1.2
Specifications ......................................................................................................... 1-7
1.3
Software ................................................................................................................. 1-8
1.4
Agency Compliance ............................................................................................... 1-8
2. Installation & Operation .............................................................................................. 2-1 2.1
InfiniBand Bridge PCI Card Installation ............................................................... 2-1
2.2
TPX-4 PCI Card Installation .................................................................................. 2-5 2.2.1 Reassembly Procedure ............................................................................. 2-13
2.3
Operation ............................................................................................................. 2-14 2.3.1 General ..................................................................................................... 2-14 2.3.2 Turning the System On ............................................................................ 2-14 2.3.3 Turning the System Off ........................................................................... 2-15
Appendix A. Connectors and LED Indicators ............................................................... A-1 A.1 InfiniBand Ports .................................................................................................... A-3 A.1.1 Fiber-Optic Connector .............................................................................. A-3 A.1.2 Copper-Wire Connector ............................................................................ A-3 A.2 Video Connectors ................................................................................................. A-4 A.2.1 Video Input ............................................................................................... A-4 A.2.2 Video Output ............................................................................................. A-5 A.3 DB9 Connector ..................................................................................................... A-6 Index
................................................................................................................ Index-1
Reader Comment Card
Themis Computer
v
TPX-4 PCI-Expansion Subsystem Installation Manual
List of Figures Figure 1-1
Front View of the TPX-4 PCI-Expansion Subsystem .................................... 1-1
Figure 1-2
TPX-4 PCI-Expansion Subsystem Flow Diagram........................................... 1-2
Figure 1-3
TPX-4 Front-Panel Controls and Indicators .................................................... 1-4
Figure 1-4
Switching Power Supply at Rear of TPX-4 ..................................................... 1-5
Figure 1-5
View of the TPX-4 Chassis with the Top Cover Off....................................... 1-5
Figure 1-6
Themis InfiniBand Bridge PCI Card ............................................................... 1-6
Figure 2-1
Location of Jumper-Pin J1203 ......................................................................... 2-3
Figure 2-2
Host InfiniBand Bridge PCI Card Connections............................................... 2-4
Figure 2-3
Top View of the TPX-4; Screws to Remove ................................................... 2-5
Figure 2-4
Location of Jumper-Pin J1602 ......................................................................... 2-6
Figure 2-5
Screws to Remove for PCI Card Installation (Bottom View) ......................... 2-7
Figure 2-6
Remove 5 Screws to Access PCI Slots 3 and 4 ............................................... 2-9
Figure 2-7
Install PCI Card in Slot 3 or 4 and Secure Faceplate Screw.......................... 2-10
Figure 2-8
Remove 2 Middle Button-Head Screws to Release Video Panel .................. 2-10
Figure 2-9
Remove the Last Screw Holding the Video Panel......................................... 2-11
Figure 2-10
Disconnect the Power-Supply Cable Connector............................................ 2-11
Figure 2-11
Remove Both Air-Flow Diverters.................................................................. 2-12
Figure 2-12
Removing the Video Panel Frees the PCI-Card Support Housing ................ 2-12
Figure 2-13
Remove the Left-Side Mounting Block . . .................................................... 2-13
Figure 2-14
Power Supply on Rear of System .................................................................. 2-15
Figure 2-15
Power Supply on Rear of System .................................................................. 2-15
Figure A-1
TPX-4 Front-Panel Connectors ...................................................................... A-2
Figure A-2
TPX-4 Fiber-Optic Connector Pinout............................................................. A-3
Figure A-3
TPX-4 Copper-Wire Connector Pinout .......................................................... A-3
Figure A-4
13W3 Video-Input Connector (Male)............................................................. A-4
vi
Themis Computer
Table of Contents
List of Tables Table 1-1
TPX-4 Major Features ..................................................................................... 1-3
Table 1-2
TPX-4 Front-Panel I/O Controls...................................................................... 1-3
Table 1-3
TPX-4 System Indicators................................................................................. 1-4
Table 1-4
TPX-4 PCI-Expansion Subsystem Specifications ........................................... 1-7
Table 2-1
Bridge PCI Card Jumper-Pin Settings (Component Side)............................... 2-2
Table 2-2
TPX-4 Interface Board Jumper-Pin Settings (Component Side)..................... 2-7
Table A-1
TPX-4 Front-Panel LEDs ............................................................................... A-2
Table A-2
TPX-4 Front-Panel I/O Controls..................................................................... A-4
Table A-3
13W3 Video-Input Pinouts ............................................................................. A-5
Table A-4
TPX-4 BNC Video-Output Connector Pinout ................................................ A-6
Themis Computer
vii
TPX-4 PCI-Expansion Subsystem Installation Manual
viii
Themis Computer
General Section Chapter
1
1
TPX-4 Overview, Specifications, & Agency Compliance 1.1
Overview The TPX-4 PCI-Expansion Subsystem (see Figure 1-1) is a self-contained I/O expansion subsystem that is 1-RU high, 19” rack-mountable, and can be used to extend the PCI capability of host systems to which it is connected; for example, the Themis RES-204s, RES-302s, RES-32XE, and RES-22XE servers, or T-210ML telecommunications server. The TPX-4 supports up to four full-length PCI cards providing data in either 32-bit or 64-bit formats running at 33 MHz (see Figure 1-2, page 1-2). Each TPX-4 contains a power supply and on-board cooling for all PCI slots. The PCI cards are interfaced with the host system through a PCI/PCI InfiniBand™ bridge operating at either 33 or 66 MHz. Before the TPX-4 can be connected to a host system, a Themis InfiniBand bridge PCI card must be installed (see “Host InfiniBand Bridge PCI Card” on page1-6.
Figure 1-1. Front View of the TPX-4 PCI-Expansion Subsystem
Themis Computer
1-1
TPX-4 PCI-Expansion Subsystem Installation Manual
A
B
Fiber-Optic Connector Port Copper-Wire Connector Port
Auto-Ranging AC Power Supply
Video Input 13W3
Note: Only one data-transfer port (A or B) may be used at the same time.
AC Power
13W3 Video Repeater and RGB Sync Restorer
SYNC on Green
Video Output BNC
Legend
RGB with HS
TPX-4 Subsystem
Fans
TPX-4 Interface PCI Slot 1 PCI Slot 2
A Fiber-Optic Port 7
Host Computer
Copper-Wire Port 6
B
33 MHz / 32 or 64 bit
InfiniBand Bridge
5 V PCI Bus
Port 7 (Optical)
InfiniBand Bridge PCI Card
PCI Slot 3 Port 6 (Copper) Not Used
PCI Slot
PCI Slot 4
Not Used
2.5-Gbit/sec
Display / Alarm Board
PCI-to-Local-Bus Interface 9050
33 MHz / 32 or 64 bit 5 V PCI Bus
Flash
eBus
Environmental Sense T1
T2
Figure 1-2. TPX-4 PCI-Expansion Subsystem Flow Diagram The TPX-4 can be ordered to support either of two types of TPX-4-to-host datatransfer media, copper-wire cable (transmission up to 17 meters long) or fiber-optic cable (transmission up to 300 meters long, multimode, or 1 kilometer, single mode) at up to 2.5-gigabits/second (Gb/s; see following Note). Only one media type can be used at the same time. Note: Transmission media (copper wire or fiber-optic cable) between the TPX-4 and host computer is configurable with jumper-pins on both the TPX-4 chassis Interface Board and the host InfiniBand Bridge PCI Card. 1-2
Themis Computer
TPX-4 Overview, Specifications, & Agency Compliance Overview
Major features of the TPX-4 are described in Table 1-1. Table 1-1. TPX-4 Major Features Feature
Details z
4 total; either 32 bit or 64 bit @ 33 MHz
z
Supports full-length cards
z
Rack-mount brackets adjust to allow front of the TPX-4 to be recessed backward, extended forward, or mounted flush with the front of the rack
z
Sun 13W3 video repeater and RGB sync restorer allows the host computer to support two monitors from a single graphics slot
TPX-4-to-host transfer speed (copper wire or fiber-optic transfer media)
z
2.5 Gbit/sec
Operating temperature
z
0°C to 50°C
Shock endurance
z
20G @ 20msec
Environmental monitoring
z
Temperature, voltage, and fan speed (relay output)
Dimensions
z 1.75” high, 16.8” wide (19” with brackets), 18” deep
PCI slots
1-RU adjustable rack-mount enclosure with slides
Graphics monitor support
z
Power supply
1.1.1
200 watts, auto-ranging (40 watts @3.3V user; 100 watts @5V user)
I/O Controls and System Indicators The TPX-4 contains I/O control connectors and system indicator LEDs as described in Table 1-2 and Table 1-3, page 1-4. All controls and 6 of 7 indicators are accessed directly from the TPX-4 front panel (see Figure 1-3 on page 1-4). Table 1-2. TPX-4 Front-Panel I/O Controls Control Video Input Video Output - RGB with HS Video Output - SYNC on green
Themis Computer
Details z
13W3 connector attaches to the video source
z
5 BNC connectors attach to the primary host monitor, providing RGB with horizontal sync (HS)
z
5 BNC connectors provide SYNC on green
1-3
TPX-4 PCI-Expansion Subsystem Installation Manual
Table 1-3. TPX-4 System Indicators See Fig. 1-3
Indicator
Details
Front Panel A
Power-on (Green)
B, C
Fiber-optic link status
D, E
Copper-wire link status
F
Not implemented
z
When lit green, power is ON and all voltages are at their proper level.
z
B—If green, the link is fully operational
z
C—If orange, a link has been established
z
D—If green, the link is fully operational
z
E—If orange, a link has been established
z
N/A
Rear Panel See Figure 1-4 & Figure 1-5
AC Power LED (Green) (on face of power supply)
z Will light green whenever the switch on the power supply at
the rear of the chassis is turned ON ( | ), indicating that power is being applied to all PCB circuits and fans.
Figure 1-3. TPX-4 Front-Panel Controls and Indicators 1-4
Themis Computer
TPX-4 Overview, Specifications, & Agency Compliance Overview
Cooling Fan
AC Socket
AC Power LED
Power On Switch
Figure 1-4. Switching Power Supply at Rear of TPX-4
Figure 1-5. View of the TPX-4 Chassis with the Top Cover Off
Themis Computer
1-5
TPX-4 PCI-Expansion Subsystem Installation Manual
1.1.2
Host InfiniBand Bridge PCI Card Communications from the host computer to the TPX-4 PCI-Expansion Subsystem is made through a Themis InfiniBand Bridge card installed on the host’s 5V, 33-MHz, 32/64-bit PCI bus (see Figure 1-6). To complete the communications link, you must install: • 1 fiber-optic cable between port 7 of the TPX-4 (see Figure 1-2, page 1-2) and port 7 of the host InfiniBand Bridge card, or • 1 copper-wire cable between port 6 of the TPX-4 (see Figure 1-2, page 1-2) and port 6 of the host InfiniBand Bridge card.
Fiber-Optic InfiniBand Port 7 (Plug not removed)
Fiber-Optic InfiniBand Port 5 (Reserved - Do Not Use)
PLD Programming Connector (Factory Use Only)
Copper-Wire InfiniBand Port 6
Copper-Wire InfiniBand Port 4 (Reserved - Do Not Use)
Figure 1-6. Themis InfiniBand Bridge PCI Card The InfiniBand Bridge card supports a single connection only, through either port 7 for a fiber-optic cable, or port 6 for a copper-wire cable. Ports 5 and 4 are reserved for future applications (see Section 2.1, “InfiniBand Bridge PCI Card Installation,” on page 2-1 for details on how to install the InfiniBand Bridge card).
1-6
Themis Computer
TPX-4 Overview, Specifications, & Agency Compliance Specifications
1.2
Specifications Table 1-4 lists general specifications for the TPX-4 PCI-Expansion Subsystem. Table 1-4. TPX-4 PCI-Expansion Subsystem Specifications Parameter
Description z
+5V (+/- 5%) @5.4A maximum 7-10 watts @3.3V, 2.7A max
z
1.75” (1RU) high
z
16.8” (42.7 cm) wide (19” with mounts)
z
18” (45.7 cm) deep
Weight (with video repeater card and connectors)
z
less than 16 pounds (9.3 kg) with 4 full-length PCI cards
z
13.76 pounds (6.3 kg) with no PCI cards
Rack Mount with Slides
z
Adjustable 19” rack-mount enclosure; can be recessed backward, extended forward, or mounted flush with the front of the rack
Reliability (MTBF)
z
125,000 hours without failure (no PCI cards installed)
Temperature Operating: Non-Operating:
z
0°C to +50°C
z
–40°C to +65°C
Relative Humidity Operating: Non-Operating:
z
8% to 95% non-condensing
z
5% to 95% non-condensing
Maximum Wet Bulb Operating: Non-Operating:
z
24.4°C, non-condensing
z
35°C, non-condensing
Shock Operating: Non-Operating:
z
20G @20msec, 1/2 sine wave
z
50G @20msec, 1/2 sine wave
z
0.67G horizontal, 0.56G vertical
z
1.04G
Acoustics
z
45 dB maximum
Altitude Operating: Non-Operating:
z
0 to 10,000 feet above sea level
z
0 to 40,000 feet above sea level
Power Dimensions
Random Vibration (RMS)
Operating: Non-Operating:
Themis Computer
1-7
TPX-4 PCI-Expansion Subsystem Installation Manual
1.3
Software The TPX-4 does not require software drivers to operate the InfiniBand link. Only drivers specific to the PCI cards installed in any of the four slots are required.
1.4
Agency Compliance The TPX-4 is designed to conform to the following regulating agency standards: • FCC—Class A Computing Device CFR 47 Part 15 Subpart J • EN 5008-1:1997 Emission Standard—EN55022 Class A • CNS 13438 Class A
1-8
Themis Computer
Installation Section Chapter
2
Installation & Operation This chapter describes: • How to install the Themis InfiniBand Bridge PCI card into a host computer. • How to install a PCI card into any of the four PCI slots of the TPX-4 PCIExpansion Subsystem. • How to turn the TPX-4 system on and off.
2.1
InfiniBand Bridge PCI Card Installation Caution: Use industry-standard ESD grounding techniques when handling all components. Wear an antistatic wrist strap and use an ESD-protected mat. Store ESD-sensitive components in antistatic bags before placing them on any surface. Handle all IC boards by the edges only. 1. Follow the host computer Operations Manual directions for opening up the host system and accessing the PCI bus slots. 2. Unfasten the Phillips screw securing the blank PCI-slot faceplate covering the slot into which you are installing the Themis InfiniBand Bridge PCI card and remove the blank faceplate.
Themis Computer
2-1
TPX-4 PCI-Expansion Subsystem Installation Manual
3. Remove the InfiniBand Bridge PCI card from its protective sleeve and examine the jumper-pin settings (see Table 2-1 and Figure 2-1 on page 2-3). Table 2-1. Bridge PCI Card Jumper-Pin Settings (Component Side) Jumper Pin
Settinga
J1203
Short 1-2
Copper InfiniBand link is used
Short 2-3
Optical InfiniBand link is used
Short 1-2
Themis personnel only
Short 2-3
Host applications
Short 1-2
Themis personnel only
Short 2-3
Host applications
J1602
J1603
Description
a—Default settings are in boldface letters.
If you are using a copper InfiniBand link (cable), make sure the jumper is over (shorting) pins 1 and 2 of J1203. If you are using an optical (fiber-optic) InfiniBand link, make sure the jumper is over (shorting) pins 2 and 3 of J1203. 4. Carefully insert the InfiniBand Bridge PCI card into the host PCI slot directly behind the open I/O panel. 5. Fasten the Bridge PCI card faceplate to the I/O panel with the Phillips screw removed in Step 2. 6. Close the host computer according to Operations Manual directions. 7. If you are using a fiber-optic cable between the host computer and the TPX-4 PCI-Expansion Subsystem, connect the cable between the host bridge PCI card’s port 7 (see Figure 2-2 on page 2-4) and the TPX-4’s port 7 (see Figure 1-3 on page 1-4). If you are using copper-wire cable between the host computer and the TPX-4 PCI-Expansion Subsystem, connect the cable between the host bridge PCI card’s port 6 (see Figure 2-2 on page 2-4) and the TPX-4’s port 6 (see Figure 1-3 on page 1-4).
2-2
Themis Computer
Installation & Operation InfiniBand Bridge PCI Card Installation
J1203
OPT
Pin 1
COP
Jumper set for Copper (pins 1-2)
Figure 2-1. Location of Jumper-Pin J1203 Themis Computer
2-3
TPX-4 PCI-Expansion Subsystem Installation Manual
Figure 2-2. Host InfiniBand Bridge PCI Card Connections
Caution: Do not attach a cable to the PLD programming connector. This connector is for Themis factory and field personnel use only.
2-4
Themis Computer
Installation & Operation TPX-4 PCI Card Installation
2.2
TPX-4 PCI Card Installation Caution: Use industry-standard ESD grounding techniques when handling all components. Wear an antistatic wrist strap and use an ESD-protected mat. Store ESD-sensitive components in antistatic bags before placing them on any surface. Handle all IC cards by the edges only. Use the following steps to install a PCI card into a TPX-4 PCI slot: 1. Remove each of the 17 Phillips-head screws (3/16” flathead; see Figure 2-3) that secure the top cover of the TPX-4 cabinet (12 screws are directly on top, 2 screws are on the left side, and 3 screws are on the right side).
Figure 2-3. Top View of the TPX-4; Screws to Remove
Themis Computer
2-5
TPX-4 PCI-Expansion Subsystem Installation Manual
2. Slide the top cover slightly toward the front to release the latches (hidden underneath the cover) that secure the rear of the cover to the chassis. This allows the cover to be lifted free from the chassis. 3. Examine the jumper-pin setting of J1602 on the TPX-4 Interface Board (see Figure 2-4) and compare it with Table 2-2 on page 2-7. If you are using a copper InfiniBand link (cable), make sure the jumper is over (shorting) pins 1 and 2 of J1602. If you are using an optical (fiber-optic) InfiniBand link, make sure the jumper is over (shorting) pins 2 and 3 of J1602.
Figure 2-4. Location of Jumper-Pin J1602
2-6
Themis Computer
Installation & Operation TPX-4 PCI Card Installation
Table 2-2. TPX-4 Interface Board Jumper-Pin Settings (Component Side) Jumper Pin
Settinga
J1102
Short 1-2
Themis personnel only
Short 2-3
Default setting; do not change
Short 1-2
Copper InfiniBand link is used
Short 2-3
Optical InfiniBand link is used
J1602
Description
a—Default settings are in boldface letters.
4. Right-Side PCI Card Access Only. If PCI cards are being removed or installed into the right-side PCI card slots (3 and 4) only, follow these substeps (otherwise, go to Step 5 on page 2-8): a. Turn the chassis over and remove the three Phillips-head (3/16” flathead) screws from the bottom of the chassis that are indicated in Figure 2-5.
Remove 3 bottom screws only for right-side PCI card access
Figure 2-5. Screws to Remove for PCI Card Installation (Bottom View)
Themis Computer
2-7
TPX-4 PCI-Expansion Subsystem Installation Manual
b. Turn the chassis back over to expose the PCI slots and remove the two 1/4” Button-Head 5/64” Allen screws in the right-hand corner of the front faceplate (see A in Figure 2-6 on page 2-9). This will release the right side beam and expose the right-hand PCI-card holding screws (see B). c. After removing the blank PCI-card faceplate covering the slot into which you are installing a PCI card, firmly insert the PCI card into the slot 3 or slot 4 backplane connector (see Figure 2-7 on page 2-10). If the card is wide enough, slide the opposite edge of the PCI card into the card channel of the right side beam. Secure each PCI card to the chassis with a standard PCI faceplate screw (see Figure 2-7). a. After all PCI cards have been installed, reassemble the TPX-4 PCI-Expansion Subsystem by reinstalling the right side beam, bottom cover, and top cover, reversing the above procedures from Step 4 to Step 1. 5. Full PCI Card Access. To access all four PCI slots (1 through 4), remove the 14 Phillips-head screws (3/16” flathead) shown in Figure 2-5 from the bottom of the TPX-4 chassis. Important: Remove only the bottom screws indicated in Figure 2-5. Removing any other screws will cause components to loosen and fall out of the TPX-4 chassis. 6. Turn the chassis back over to expose the PCI slots and remove the two 1/4” Button-Head 5/64” Allen screws in the right-hand corner of the front of the TPX-4 chassis (see A in Figure 2-6 on page 2-9). This will release the right side beam and expose the right-hand PCI-card holding screws (see B). 7. Remove the two 1/4” Button-Head 5/64” Allen screws shown in Figure 2-8 on page 2-10. This will release the right edge of the front video panel to free the center support housing holding the PCI-slot backplane. 8. To disconnect the video panel from the chassis, remove the flathead Phillips screw shown in Figure 2-9 on page 2-11. 9. Remove the center support housing containing slots 1 through 4 of the PCI backplane as follows: a. Disconnect the power-supply cable connector at the rear of the chassis (see A and B, Figure 2-10 on page 2-11).
2-8
Themis Computer
Installation & Operation TPX-4 PCI Card Installation
A B
Figure 2-6. Remove 5 Screws to Access PCI Slots 3 and 4
Themis Computer
2-9
TPX-4 PCI-Expansion Subsystem Installation Manual
PCI Faceplate Screw Install PCI Card
Figure 2-7. Install PCI Card in Slot 3 or 4 and Secure Faceplate Screw
Figure 2-8. Remove 2 Middle Button-Head Screws to Release Video Panel 2-10
Themis Computer
Installation & Operation TPX-4 PCI Card Installation
Figure 2-9. Remove the Last Screw Holding the Video Panel
A
B Figure 2-10. Disconnect the Power-Supply Cable Connector b. Remove the two air-flow diverters (sponge foam held by dual-stick tape) shown in Figure 2-11 on page 2-12) c. Carefully pull out the center support housing (see Figure 2-12, page 2-12). 10. Before you can install PCI cards into slots 1 and 2, a mounting block must be removed from the left side of the PCI-card center support housing (see Figure 2-13 on page 2-13). Removing the two Phillips screws that hold this block allows access to the PCI faceplates.
Themis Computer
2-11
TPX-4 PCI-Expansion Subsystem Installation Manual
Figure 2-11. Remove Both Air-Flow Diverters
Figure 2-12. Removing the Video Panel Frees the PCI-Card Support Housing 2-12
Themis Computer
Installation & Operation TPX-4 PCI Card Installation
Figure 2-13. Remove the Left-Side Mounting Block . . . 11. Install a PCI Card into slot 1 and/or slot 2 and replace the mounting block removed in Step 10. Tighten the two screws through the mounting block. 12. Before reassembling the system, install a PCI card into slot 3 and/or slot 4 (see Step 4c).
2.2.1
Reassembly Procedure After all PCI cards have been installed, reassemble the TPX-4 PCI-Expansion Subsystem by reinstalling the center support housing, front video panel, bottom cover, and top cover, reversing the above procedures from Step 11 to Step 1.
Themis Computer
2-13
TPX-4 PCI-Expansion Subsystem Installation Manual
2.3 2.3.1
Operation General To ensure adequate cooling within the TPX-4, the system should not be operated with the top cover off. System fans pull air into the chassis, hence the TPX-4 must be closed to provide for proper airflow. Make sure that jumper-pins J1203 on the Bridge PCI card and J1602 on the TPX-4 Interface board have been configured for the same type of link (both copper or both optical). See Table 2-1 on page 2-2 and Table 2-2 on page 2-7 for details.
Caution: Configure jumper-pins J1203 (Bridge PCI card) and J1602 (TPX-4 Interface board) for the same type of link, either copper or optical. After the InfiniBand Bridge PCI card has been installed in the host computer, the TPX-4 must be turned on and connected to the Bridge PCI card through either the copper or the fiber-optic link, otherwise the host computer may or may not boot.
Caution: Make sure the TPX-4 is turned on and connected to the Bridge PCI card through either the copper or the fiber-optic link before turning the host computer on.
2.3.2
Turning the System On 1. Plug the AC power cord (shipped with the unit) into the AC socket on the rear of the TPX-4 (see Figure 2-14 on page 2-15). Caution: It is important that the TPX-4 be turned on before the host computer (the Themis T-210 server, for example) so that it is recognized by the host during its boot process. 2. Push the power supply on/off switch to the ON ( | ) position. If power is present, the AC power supply LED (rear panel) and the power-on LED (front panel; see Figure 2-15, page 2-15) will both light green.
2-14
Themis Computer
Installation & Operation Operation
Figure 2-14. Power Supply on Rear of System 3. Make sure that the InfiniBand communications link—either fiber-optic or copper wire—is connected between the TPX-4 and the host system (see Section 2.1, “InfiniBand Bridge PCI Card Installation,” on page 2-1). 4. Turn on the host computer and watch the two LED indicators on the TPX-4 front panel above the attached InfiniBand connector (the fiber-optic connector has 2 LEDs above it, and the copper-wire connector 2 LEDs above it): • If the left LED turns green, the link is fully operational • If the right LED turns orange, a link has been established
Figure 2-15. Power Supply on Rear of System
2.3.3
Turning the System Off 1. To turn the TPX-4 off, push the power supply on/off switch (rear panel) to the OFF ( O ) position. This will shut down the system and turn off all LEDs.
Themis Computer
2-15
TPX-4 PCI-Expansion Subsystem Installation Manual
2-16
Themis Computer
A
Appendix
Connectors and LED Indicators This appendix provides connector definitions and pinouts for user all I/O interfaces used on the TPX-4 PCI-Expansion Subsystem. It also provides a description of all LED indicators on the front panel of the system. All interface connectors are mounted on the front panel of the chassis (see Figure A-1 on page A-2). Table A-1, page A-2, defines the LED indicators on the front panel.
Themis Computer
A-1
TPX-4 PCI-Expansion Subsystem Installation Manual
Figure A-1. TPX-4 Front-Panel Connectors Table A-1. TPX-4 Front-Panel LEDs See Fig. A-1 A
Power-on (Green)
B, C
Fiber-optic link status
D, E
Copper-wire link status
F
A-2
Indicator
Not implemented
Description z
When lit green, power is ON and all voltages are at their proper level.
z
B—If green, the link is fully operational
z
C—If orange, a link has been established
z
D—If green, the link is fully operational
z
E—If orange, a link has been established
z
N/A
Themis Computer
Connectors and LED Indicators InfiniBand Ports
A.1
InfiniBand Ports There are two InfiniBand ports on the front of the TPX-4: one for a fiber-optic cable and another for a copper-wire cable.
A.1.1
Fiber-Optic Connector • Connector Type: Optical GBIC Small Footprint (Themis #110374-001) • Manufacturer, Part Number: Transceiver, Optical, InfiniBand, Finstar FTRJ-8519-1-2.5 Figure A-2 describes the connector pinout for the fiber-optic connector. Tx
Rx
Figure A-2. TPX-4 Fiber-Optic Connector Pinout
A.1.2
Copper-Wire Connector • Connector Type: 7-pin RA InfiniBand connector (Themis #110303-001) • Manufacturer, Part Number: CON, TP, InfiniBand Molex 74703-0007, 74703-0307 Figure A-3 describes the connector pinout for the copper-wire connector.
7
1
1 = GND 2 = Rx+ 3 = Rx4 = GND
5 = Tx6 = Tx+ 7 = GND
Figure A-3. TPX-4 Copper-Wire Connector Pinout
Themis Computer
A-3
TPX-4 PCI-Expansion Subsystem Installation Manual
A.2
Video Connectors There are three sets of video connectors on the front of the TPX-4 (see Table A-2). Table A-2. TPX-4 Front-Panel I/O Controls Connector Set Video Input
Details z
One 13W3 connector attaches to the video source.
z
RGB output with Horizontal SYNC. All connectors attach to the primary host monitor.
z
All BNC connectors generate SYNC on green.
Video Output Five BNC connectors Five BNC connectors
A.2.1
Video Input • Connector Type: 13W3 video input connector (male) (No Themis P/N, board level) Figure A-4 and Table A-3, page A-5, describe the 13W3 connector and its pinouts.
5 4 3 2 1 A3
A2
10 9 8 7 6
A1
Figure A-4. 13W3 Video-Input Connector (Male)
A-4
Themis Computer
Connectors and LED Indicators Video Connectors
Table A-3. 13W3 Video-Input Pinouts Pin
A.2.2
Function
A1
RED signal
A2
GREEN signal
A3
BLUE signal
1
Serial read (SERREAD)
2
Vertical synchronization (VS)
3
SENSE0
4
Ground (GND)
5
Composite synchronization (CS)
6
Horizontal synchronization (HS)
7
Serial write (SERWRITE)
8
SENSE1
9
SENSE2
10
Ground (GND)
Video Output • Connector Type: BNC (No Themis P/N, board level) Table A-4, page A-6, describes the pinouts for all BNC video-output connectors.
Themis Computer
A-5
TPX-4 PCI-Expansion Subsystem Installation Manual
Table A-4. TPX-4 BNC Video-Output Connector Pinout BNC Set Left Side
Right Side
Pin
BNC Connector Red
Green
Blue
Gray
Black
Center Wire
Red Analog Video (R1)
Green Analog Video (G1)
Blue Analog Video (B1)
Horizontal Sync (HS1)
Vertical Sync (VS1)
Shield
Ground
Ground
Ground
Ground
Ground
Center Wire
Red Analog Video (R2)
SYNC on Green, Analog Video (G2)
Blue Analog Video (B2)
Unconnected (HS2)
Unconnected (VS2)
Shield
Ground
Ground
Ground
Ground
Ground
Center Wire
Shield
A.3
DB9 Connector At the present time, the female DB9 port is reserved for future use.
A-6
Themis Computer
Index Numerics 13W3 video input connector A-4 A adjustable rack-mount enclosure 1-3 Agency Compliance 1-8 antistatic bags 2-1, 2-5 antistatic wrist strap 2-1, 2-5 B BNC video-output connector A-5 C CNS 1-8 Connectors A-1 copper-wire cable 1-2, 1-6, A-3 copper-wire connector A-3 D Dimensions 1-3 E Emission Standard 1-8 Environmental monitoring 1-3 ESD grounding techniques 2-1, 2-5 protected mat 2-1, 2-5 F FCC 1-8 fiber-optic cable 1-2, 1-6, A-3 fiber-optic connector A-3 Front-Panel Connectors A-2 G Graphics monitor support 1-3
Themis Computer
I InfiniBand bridge 1-1 InfiniBand Bridge PCI board, host computer 2-1 InfiniBand Bridge PCI card, host computer 1-6 InfiniBand ports A-3 installation PCI card 2-1 L LED Indicators A-1 M Major features of the TPX-4 1-3 O Operating temperature 1-3 P PCI board 1-1 PCI card installation 2-1 PCI cards 1-1 PCI slots 1-3 PCI-to-PCI bridge 1-1 Power supply 1-3 R RES-204s RAID server 1-1 RES-22XE server 1-1 RES-302s server 1-1 RES-32XE server 1-1 RGB Output 1-3 S Shock endurance 1-3 signal transmission 1-2
Index-1
TPX-4 PCI-Expansion Subsystem Installation Manual
Specifications Acoustics 1-7 Altitude 1-7 Dimensions 1-7 Humidity, relative 1-7 Power 1-7 Rack Mount 1-7 Reliability 1-7 Shock 1-7 Temperature 1-7 Vibration 1-7 Weight 1-7 Wet Bulb, maximum 1-7 specifications 1-7 System Indicators 1-4 T T-210ML telecommunications server 1-1 TPX-4 PCI-Expansion Subsystem 1-1 transfer speed, TPX-4 to host 1-3 Transmission media 1-2 V video connectors A-4 Video Input 1-3, A-4 Video Output 1-3, A-5
Index-2
Themis Computer
Place Stamp Here
Themis Computer 3185 Laurel View Court Fremont, CA 94538 Attn: Publications Department
Fold here; tape at top to seal
Reader Comment Card We welcome your comments and suggestions to help improve the TPX-4 PCI-Expansion Subsystem Installation Manual. Please take time to let us know what you think about this manual. •
Information provided in the manual was complete. Agree___
•
Not Applicable___
Disagree___
Not Applicable___
Disagree___
Not Applicable___
The manual was useful. Agree___
•
Disagree___
Information was easily accessible. Agree___
•
Not Applicable___
Information was well documented and easy to follow. Agree___
•
Disagree___
Please write down any comments you may have about this manual, including how it can be improved: ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________
Name:
_____________________________________________________
Title:
_____________________________________________________
Company:
_____________________________________________________
Address:
_____________________________________________________