Preview only show first 10 pages with watermark. For full document please download

Tq Relays Features 5 Mm Low Profile,

   EMBED


Share

Transcript

5 mm Low profile, 2 Form C and 2 A (surfacemount type) relays TQ RELAYS FEATURES 1. Flat compact size 14.0 (L) × 9.0 (W) × 5.0 (H) mm .551 (L) × .354 (W) × .197 (H) inch 2. Nominal operating power: High sensitivity of 140mW (2 Form C single side stable type) 3. Suitable for SMD automatic insertion (SA type) With a height of 5.6 mm .220 inch, the relays meet JIS C 0806 specifications. 4. DIL terminal array enables use of IC sockets 5. Low thermal electromotive force (approx. 5 μV) [approx. 2 μV (surface-mount type)] 6. Latching types also available 7. Self-clinching terminal also available RoHS compliant 8. A range of surface-mount types is also available SA: Low-profile surface-mount terminal type SL: High connection reliability surfacemount terminal type SS: Space saving surface-mount terminal type 9. M.B.B. contact types available TYPICAL APPLICATIONS 1. Telephone-related equipment 2. Communications 3. Measurement equipment 4. OA equipment 5. Industrial machines ORDERING INFORMATION TQ 2 Contact arrangement 2: 2 Form C Terminal shape Nil: Standard PC board terminal H: Self-clinching terminal SA: SA type SL: SL type SS: SS type Operating function Nil: Single side stable L: 1 coil latching L2: 2 coil latching MBB function Nil: Standard (B.B.M.) type 2M: 2M.B.B. type Nominal coil voltage (DC)* 1.5 (SMD only), 3, 4.5, 5, 6, 9, 12, 24, 48V Packing style Nil: Tube packing X: Tape and reel (picked from 1/2/3/4/5-pin side) Z: Tape and reel packing (picked from the 6/7/8/9/10-pin side) Notes: 1. *48 V coil type: Single side stable only 2. In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay. –1– ASCTB14E 201407-T TQ TYPES ■ Standard PC board terminal and self-clinching terminal 1. Standard (B.B.M.) type 1) Standard PC board terminal Contact arrangement Nominal coil voltage 2 Form C 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC Single side stable Part No. TQ2-3V TQ2-4.5V TQ2-5V TQ2-6V TQ2-9V TQ2-12V TQ2-24V TQ2-48V 1 coil latching Part No. TQ2-L-3V TQ2-L-4.5V TQ2-L-5V TQ2-L-6V TQ2-L-9V TQ2-L-12V TQ2-L-24V — 2 coil latching Part No. TQ2-L2-3V TQ2-L2-4.5V TQ2-L2-5V TQ2-L2-6V TQ2-L2-9V TQ2-L2-12V TQ2-L2-24V — 1 coil latching Part No. TQ2H-L-3V TQ2H-L-4.5V TQ2H-L-5V TQ2H-L-6V TQ2H-L-9V TQ2H-L-12V TQ2H-L-24V — 2 coil latching Part No. TQ2H-L2-3V TQ2H-L2-4.5V TQ2H-L2-5V TQ2H-L2-6V TQ2H-L2-9V TQ2H-L2-12V TQ2H-L2-24V — Standard packing (2 Form C): Tube: 50 pcs.; Case: 1,000 pcs. 2) Self-clinching terminal Contact arrangement Nominal coil voltage 2 Form C 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC Single side stable Part No. TQ2H-3V TQ2H-4.5V TQ2H-5V TQ2H-6V TQ2H-9V TQ2H-12V TQ2H-24V TQ2H-48V Note: Types (“-3” to the end of part No.) designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered. However, please contact us if you need parts for use in low level load. 2. M.B.B. type 1) Standard PC board terminal Contact arrangement Nominal coil voltage 2 Form C 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC Single side stable Part No. TQ2-2M-3V TQ2-2M-4.5V TQ2-2M-5V TQ2-2M-6V TQ2-2M-9V TQ2-2M-12V TQ2-2M-24V Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. 2) Self-clinching terminal Contact arrangement Nominal coil voltage 2 Form C 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC Single side stable Part No. TQ2H-2M-3V TQ2H-2M-4.5V TQ2H-2M-5V TQ2H-2M-6V TQ2H-2M-9V TQ2H-2M-12V TQ2H-2M-24V Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. Notes: 1. Latching types are available by request. Please consult us for details. 2. UL/CSA approved (UL file No.:E 43149, CSA file No.: LR26550) 3. Types (“-1” to the end of part No.) designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered. However, please contact us if you need parts for use in low level load and low thermal power. –2– ASCTB14E 201407-T TQ ■ Surface-mount terminal 1) Tube packing Contact arrangement Nominal coil voltage 2c 1.5 V DC 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC Single side stable Part No. TQ2S-1.5V TQ2S-3V TQ2S-4.5V TQ2S-5V TQ2S-6V TQ2S-9V TQ2S-12V TQ2S-24V TQ2S-48V 1 coil latching Part No. TQ2S-L-1.5V TQ2S-L-3V TQ2S-L-4.5V TQ2S-L-5V TQ2S-L-6V TQ2S-L-9V TQ2S-L-12V TQ2S-L-24V — 2 coil latching Part No. TQ2S-L2-1.5V TQ2S-L2-3V TQ2S-L2-4.5V TQ2S-L2-5V TQ2S-L2-6V TQ2S-L2-9V TQ2S-L2-12V TQ2S-L2-24V — : For each surface-mounted terminal identification, input the following letter. SA type: A, SL type: L, SS type: S Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. 2) Tape and reel packing Contact arrangement Nominal coil voltage 2 Form C 1.5 V DC 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC Single side stable Part No. TQ2S-1.5V-Z TQ2S-3V-Z TQ2S-4.5V-Z TQ2S-5V-Z TQ2S-6V-Z TQ2S-9V-Z TQ2S-12V-Z TQ2S-24V-Z TQ2S-48V-Z 1 coil latching Part No. TQ2S-L-1.5V-Z TQ2S-L-3V-Z TQ2S-L-4.5V-Z TQ2S-L-5V-Z TQ2S-L-6V-Z TQ2S-L-9V-Z TQ2S-L-12V-Z TQ2S-L-24V-Z — 2 coil latching Part No. TQ2S-L2-1.5V-Z TQ2S-L2-3V-Z TQ2S-L2-4.5V-Z TQ2S-L2-5V-Z TQ2S-L2-6V-Z TQ2S-L2-9V-Z TQ2S-L2-12V-Z TQ2S-L2-24V-Z — : For each surface-mounted terminal identification, input the following letter. SA type: A, SL type: L, SS type: S Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs. Note: Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available. RATING ■ Standard PC board terminal and self-clinching terminal 1. Coil data [Standard (B.B.M.) type] 1) Single side stable (2 Form C) Nominal coil voltage 3 Drop-out voltage (at 20°C 68°F) V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 Pick-up voltage (at 20°C 68°F) Nominal operating current [±10%] (at 20°C 68°F) 46.7 mA 75%V or less of nominal voltage* (Initial) 10%V or more of nominal voltage* (Initial) V DC 31.1 28.1 23.3 15.5 11.7 8.3 mA mA mA mA mA mA 6.25 mA Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20°C 68°F) 140 mW 150%V of nominal voltage 64.3 Ω 144.6 Ω 178 Ω 257 Ω 579 Ω 1,028 Ω 2,880 Ω 7,680 Ω 200 mW 300 mW 120%V of nominal voltage Nominal operating power Max. applied voltage (at 20°C 68°F) 100 mW 150%V of nominal voltage 2) 1 coil latching (2 Form C) Nominal coil voltage 3 Set voltage (at 20°C 68°F) Reset voltage (at 20°C 68°F) V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 75%V or less of nominal voltage* (Initial) 75%V or less of nominal voltage* (Initial) Nominal operating current [±10%] (at 20°C 68°F) 33.3 mA 22.2 mA 20 mA 16.7 mA 11.1 mA 8.3 mA 6.3 mA –3– Coil resistance [±10%] (at 20°C 68°F) 90 Ω 202.5 Ω 250 Ω 360 Ω 810 Ω 1,440 Ω 3,840 Ω 150 mW ASCTB14E 201407-T TQ 3) 2 coil latching (2 Form C) Nominal coil voltage 3 Set voltage (at 20°C 68°F) Reset voltage (at 20°C 68°F) Nominal operating current [±10%] (at 20°C 68°F) Set coil Reset coil V DC 66.7 mA 66.7 mA 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 44.4 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 44.4 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 12.5 mA 12.5 mA 24 75%V or less of nominal voltage* (Initial) 75%V or less of nominal voltage* (Initial) V DC Coil resistance [±10%] (at 20°C 68°F) Set coil 45 101.2 Ω 125 Ω 180 Ω 405 Ω 720 Ω 1,920 Reset coil Ω Ω 45 Max. applied voltage (at 20°C 68°F) Set coil Reset coil 200 mW 200 mW 150%V of nominal voltage 300 mW 300 mW 120%V of nominal voltage Ω 101.2 Ω 125 Ω 180 Ω 405 Ω 720 Ω 1,920 Nominal operating power Ω [M.B.B. type] Nominal coil voltage 3 Drop-out voltage (at 20°C 68°F) Pick-up voltage (at 20°C 68°F) V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 80%V or less of nominal voltage* (Initial) 10%V or more of nominal voltage* (Initial) Nominal operating current [±10%] (at 20°C 68°F) 66.7 mA Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20°C 68°F) 200 mW 150%V of nominal voltage 45 Ω 101 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω 44.4 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA *Pulse drive (JIS C 5442-1986) 2. Specifications Characteristics Contact Rating Item Arrangement Initial contact resistance, max. Contact material Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1 Specifications 2 Form C, 2 Form D (M.B.B.) Max. 50mΩ (By voltage drop 6 V DC 1A) Ag+Au clad 1 A 30 V DC, 0.5 A 125 V AC (resistive load) 30 W (DC), 62.5 V A (AC) (resistive load) 110 V DC, 125 V AC 1A 10μA 10mV DC Single side stable Nominal operating power 1 coil latching 2 coil latching Standard (B.B.M) type: 140 mW (3 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC) M.B.B. type: 200 mW 100 mW (3 to 12 V DC), 150 mW (24 V DC) 200 mW (3 to 12 V DC), 300 mW (24 V DC) Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section. Between open contacts Electrical characteristics Breakdown voltage (Initial) Between contact and coil Between contact sets Temperature rise (at 20°C 68°F) Operate time [Set time] (at 20°C 68°F) Release time [Reset time] (at 20°C 68°F) Mechanical characteristics Expected life Conditions Shock resistance Functional Destructive Functional Destructive Mechanical (at 180 cpm) Vibration resistance Electrical (at 20 cpm) Conditions for operation, transport and storage*2 Max. operating speed (at rated load) Unit weight Standard (B.B.M) type: 750 Vrms for 1min. (Detection current: 10 mA), M.B.B. type: 300 Vrms for 1 min. (Detection current: 10 mA) 1,000 Vrms for 1min. (Detection current: 10 mA) 1,000 Vrms for 1min. (Detection current: 10 mA) Max. 50°C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.) Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 490 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5 mm Standard (B.B.M) type: Min. 108, M.B.B. type: Min. 107 Standard (B.B.M) type: Min. 2×105 (1 A 30 V DC resistive), Min. 105 (0.5 A 125 V AC resistive) M.B.B. type: Min. 105 (1 A 30 V DC resistive) Standard (B.B.M) type: Ambient temperature: –40°C to +70°C –40°F to +158°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) M.B.B. type: Ambient temperature: –40°C to +50°C –40°F to +122°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 cpm Approx. 1.5 g .053 oz Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load switching (10V DC, 10mA max. level). *2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES. –4– ASCTB14E 201407-T TQ ■ Surface-mount terminal 1. Coil data 1) Single side stable Nominal operating current (at 20°C 68°F) Coil resistance [±10%] (at 20°C 68°F) 1.5 V DC 93.8 mA 16 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 46.7 mA 31 mA 28.1 mA 23.3 mA 15.5 mA 11.7 mA 8.3 mA 64.3 Ω 145 Ω 178 Ω 257 Ω 579 Ω 1,028 Ω 2,880 Ω Nominal coil voltage 48 Pick-up voltage (at 20°C 68°F) 75%V or less of nominal voltage* (Initial) Drop-out voltage (at 20°C 68°F) 10%V or more of nominal voltage* (Initial) V DC 6.3 mA 7,680 Nominal operating power Max. applied voltage (at 20°C 68°F) 140 mW 150%V of nominal voltage Ω Ω 200 mW 300 mW 120%V of nominal voltage Nominal operating power Max. applied voltage (at 20°C 68°F) 70 mW 150%V of nominal voltage 2) 1 coil latching 1.5 V DC Nominal operating current (at 20°C 68°F) 46.9 mA 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 23.3 mA 15.6 mA 14 mA 11.7 mA 7.8 mA 5.8 mA Nominal coil voltage 24 Set voltage (at 20°C 68°F) 75%V or less of nominal voltage* (Initial) Reset voltage (at 20°C 68°F) 75%V or less of nominal voltage* (Initial) V DC 4.2 mA Coil resistance [±10%] (at 20°C 68°F) 32 Ω 128.6 Ω 289.3 Ω 357 Ω 514 Ω 1,157 Ω 2,057 Ω 5,760 Ω 100 mW 3) 2 coil latching Nominal coil voltage 1.5 V DC 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC Set voltage (at 20°C 68°F) 75%V or less of nominal voltage* (Initial) Reset voltage (at 20°C 68°F) 75%V or less of nominal voltage* (Initial) Nominal operating current (at 20°C 68°F) Set coil Reset coil 93.8 mA 93.8 mA 46.7 mA 31 mA 28.1 mA 23.3 mA 15.5 mA 11.7 mA 8.3 mA 46.7 mA 31 mA 28.1 mA 23.3 mA 15.5 mA 11.7 mA 8.3 mA Coil resistance [±10%] (at 20°C 68°F) Set coil 16 Ω Reset coil 16 Ω 64.3 Ω 145 Ω 178 Ω 257 Ω 579 Ω 1,028 Ω 2,880 Ω 64.3 Ω 145 Ω 178 Ω 257 Ω 579 Ω 1,028 Ω 2,880 Ω Nominal operating power Set coil Reset coil 140 mW 140 mW 200 mW 200 mW Max. applied voltage (at 20°C 68°F) 150%V of nominal voltage *Pulse drive (JIS C 5442-1986) –5– ASCTB14E 201407-T TQ 2. Specifications Characteristics Contact Rating Item Arrangement Initial contact resistance, max. Contact material Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1 Nominal operating power Single side stable 1 coil latching 2 coil latching Insulation resistance (Initial) Electrical characteristics 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) Surge breakdown voltage (Initial) Between open contacts Between contacts and coil 1,500 V (10×160μs) (FCC Part 68) 2,500 V (2×10μs) (Bellcore) Max. 50°C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10μs.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5 mm Min. 108 (at 180 cpm) Min. 105 (2 A 30 V DC resistive), Min. 2×105 (1 A 30 V DC resistive), Min. 105 (0.5 A 125 V AC resistive) (at 20 cpm) Ambient temperature: –40°C to +85°C –40°F to +185°F, Max. –40°C to +70°C (2A) Max. –40°F to +158°F (2A); Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 cpm Approx. 2 g .071 oz Release time [Reset time] (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical Shock resistance Conditions Electrical Conditions for operation, transport and storage*2 Max. operating speed (at rated load) Unit weight 140 mW (1.5 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC) 70 mW (1.5 to 12 V DC), 100 mW (24 V DC) 140 mW (1.5 to 12 V DC), 200 mW (24 V DC) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section. Between open contacts Between contact and coil Between contact sets Operate time [Set time] (at 20°C 68°F) Expected life 10μA 10mV DC Breakdown voltage (Initial) Temperature rise (at 20°C 68°F) Mechanical characteristics Specifications 2 Form C Max. 75 mΩ (By voltage drop 6 V DC 1A) AgNi type+Au clad 2 A 30 V DC, 0.5 A 125 V AC (resistive load) 60 W (DC), 62.5 VA (AC) (resistive load) 220 V DC, 125 V AC 2A Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (TX/TX-S/TX-D relay AgPd contact type are available for low level load switching [10V DC, 10mA max. level]) *2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES. –6– ASCTB14E 201407-T TQ REFERENCE DATA ■ Standard PC board terminal and self-clinching terminal 1. Maximum switching capacity 2. Life curve 3. Mechanical life 1.0 0.5 0.4 0.3 Ratio against the rated voltage, %V DC load (cosϕ=1) AC load (cosϕ=1) No. of operations, ×104 Switching current, A Tested sample: TQ2-12V, 10 pcs. 30 V DC resistive load 100 125 V AC resistive load 10 0.2 30 0 100 200 Switching voltage,V 100 90 80 Pick-up voltage Max. Min. 70 60 50 40 Drop-out voltage 30 Max. 20 Min. 10 0 0.5 1.0 Switching current, A 10 100 1,000 10,000 No. of operations, ×104 4.-(1) Electrical life (DC load) 4.-(2) Electrical life (AC load) Tested sample: TQ2-12V, 6 pcs. Condition: 1 A 30 V DC resistive load, 20 cpm Tested sample: TQ2-12V, 6 pcs. Condition: 0.5 A 125 V AC resistive load, 20 cpm Change of contact resistance 100 90 90 Pick-up voltage Max. 70 Min. 60 50 40 Drop-out voltage Max. 30 20 Min. 80 70 60 50 Max. 40 Min. 30 20 10 10 0 5 10 15 No. of operations, ×104 20 Change of contact resistance 0 5 10 15 No. of operations, ×104 50 40 Max. 30 Min. Max. Min. 60 50 40 Drop-out voltage Max. 30 Min. 20 10 0 5 No. of operations, ×104 10 Tested sample: TQ2-12V, 5 pcs. Temperature rise, C° 60 Pick-up voltage 70 6. Ambient temperature characteristics 70 70 80 Tested sample: TQ2-12V Measured portion: Inside the coil Ambient temperature: 30°C 86°F 90 80 20 90 5. Coil temperature rise (2C) 100 Contact resistance, mΩ 100 Variation ratio,% 80 Change of pick-up and drop-out voltage Ratio against the rated voltage, %V 100 Contact resistance, mΩ Ratio against the rated voltage, %V Change of pick-up and drop-out voltage Nominal coil voltage 3 to 12 V DC type 24 V DC type 60 1A 50 40 30 Drop-out 20 voltage x x 10 40 1A 0A -40 -20 0 20 40 30 -10 20 Pick-up voltage 60 80 Ambient temperature,°C -20 20 10 10 0 5 No. of operations, ×104 0 10 7.-(1) High-frequency characteristics (Isolation) -30 -40 100 110 120 130 140 150 Coil applied voltage, %V 7.-(2) High-frequency characteristics (Insertion loss) 8. Malfunctional shock (single side stable) Tested sample: TQ2-12V, 6 pcs. , Insertion loss, dB Isolation, dB ,Z XX 100 50 Z Y, Y Z 980m/s2 980m/s2 , Z 980m/s2 , X 0.8 980m/s2 , Y 0.2 1,000 980m/s2 1.0 0.4 100 Frequency, MHz Deenergized condition Energized condition X 0.6 10 Y 980m/s2 0 10 100 Frequency, MHz –7– 1,000 ASCTB14E 201407-T TQ 9.-(1) Influence of adjacent mounting 9.-(2) Influence of adjacent mounting 10. Contact reliability (1 mA 5 V DC resistive load) 10 ON Pick-up voltage Rate of change, % Rate of change, % Rate of change, % Rate of change, % Tested sample: TQ2-12V Condition: Detection level 10 W ON 0 –10 ON OFF OFF 10 Drop-out voltage 0 OFF –10 0 10 Pick-up voltage ON 70.0 50.0 30.0 0 –10 ON 10 10.0 5.0 OFF Drop-out voltage 2.0 1.0 0.5 0 OFF –10 5 .197 Inter-relay distance , mm inch m=2.15 μ=2.7×107 95% reliability limit = 7.6×106 (Weibull probability paper) 0.2 0.1 1.0 OFF 0 5 .197 Inter-relay distance ON F(t), % 99.9 99.0 95.0 10 100 No. of operations, ×106 , mm inch 11. Actual load test (35 mA 48 V DC wire spring relay load) Change of pick-up and drop-out voltage 220Ω 57 V DC 220Ω 100 90 90 80 Pick-up voltage 70 Max. Min. 60 50 40 30 Drop-out voltage Max. Min. 20 10 12. 0.1 A 53 V DC resistive load test Change of pick-up and drop-out voltage 80 70 60 50 40 Max. 30 Min. 20 10 0 Wire spring relay Circuit diagram 10 20 30 40 No. of operations, ×104 50 0 10 20 30 40 No. of operations, ×104 50 Change of contact resistance 100 100 90 80 Pick-up voltage Max. Min. 70 60 50 40 30 Drop-out voltage 20 Max. Min. 10 0 500 1,000 1,500 Contact resistance, mΩ Ratio against the rated voltage, %V 100 Ratio against the rated voltage, %V 20Hz Change of contact resistance Contact resistance, mΩ Circuit 90 80 70 60 Max. 50 40 30 Min. 20 10 2,000 0 500 No. of operations, ×104 1,000 1,500 2,000 No. of operations, ×104 13. Distribution of M.B.B. time Tested sample: TQ2-2M-5V, 85 pcs. 50 40 30 20 26 19 15 21 Terminal Nos. 2-3-4: ON − x: 105.6 μs 3σn-1: 163.8 μs Min.: 23 μs Max.: 243 μs Terminal Nos. 7-8-9: ON − x: 115.6 μs 3σn-1: 167.3 μs 30 Min.: 35 μs Max.: 254 μs 19 60 41 40 35 31 30 27 20 17 12 11 10 Terminal Nos. 2-3-4: OFF − x: 71.6 μs 3σn-1: 127.1 μs Min.: 17 μs Max.: 187 μs Terminal Nos. 7-8-9: OFF − x: 80.7 μs 3σn-1: 156.7 μs Min.: 29 μs Max.: 298 μs 50 10 6 10 200 250 300 350 μs max. 100 150 ~ 150 2 50 ~ 100 1 10 ~ ~ 50 0 7 4 ~ ~ 300 μs min. 200 250 300 μs min. 50 100 150 200 250 300 350 μs max. ~ ~ 4 200 250 ~ 100 150 ~ 50 ~ 10 ~ 0 ~ 2 –8– ~ 60 ASCTB14E 201407-T TQ ■ Surface-mount terminal 1. Maximum switching capacity 2. Life curve 3. Mechanical life (mounting by IRS method) Ratio against the rated voltage, %V Tested sample: TQ2SA-12V, 10 pcs. No. of operations, × 104 Switching current, A 3.0 2.0 100 DC resistive load 1.0 AC resistive load 0.5 0.4 0.3 50 30 125V AC resistive load 30V DC resistive load 20 10 0.2 100 90 80 Pick-up voltage 70 Max. 60 Min. 50 40 Drop-out voltage 30 Max. 20 Min. 10 0 50 100 200 300 Contact voltage, V 0 1.0 2.0 Switching current, A 4.-(1) Electrical life (2 A 30 V DC resistive load) Tested sample: TQ2SA-12V, 6 pcs. Operating speed: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method) 90 Pick-up voltage Max. Min. 60 50 40 Drop-out voltage 30 Max. 20 IRS 1 2 70 60 50 Max. 40 Min. 30 0 50 Max. 40 Min. 30 IRS 1 2 Coil voltage DC 12V type DC 48V type 0A 50 2A 40 0A 30 4 5 6 7 8 0 9 10 No. of operations, ×104 7. Ambient temperature characteristics 0 8.-(1) High-frequency characteristics (Isolation) IRS 1 2 3 4 5 6 7 8 9 10 No. of operations, ×104 Operate time Release time 4 Max. Min. 3 2 Max. Min. 70 80 90 100 110 120 Coil applied voltage, %V 8.-(2) High-frequency characteristics (Insertion loss) 40 20 Pick-up voltage x Drop-out voltage 20 40 60 80 Ambient temperature, °C –20 Isolation, dB –40 –20 Rate of change, % Tested sample: TQ2SA-12V, 5 pcs. Min. 0 100 110 120 130 140 150 Coil applied voltage, %V Insertion loass, dB 3 Max. 20 1 10 2 Drop-out voltage 30 5 2A 20 10 IRS 1 40 0 3 4 5 6 7 8 9 10 No. of operations, ×104 20 0 Min. 50 Tested sample: TQ2SA-12V, 6 pcs. 60 Max. 60 6. Operate/release time Temperature rise, °C 60 Pick-up voltage 70 10 70 70 80 Tested sample: TQ2SA-12V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F 90 80 90 5. Coil temperature rise 100 Contact resistance, mΩ 80 10 3 4 5 6 7 8 9 10 No. of operations, ×104 Change of contact resistance (mounting by IRS method) 100 20 Min. 10 0 Contact resistance, mΩ 100 90 Ratio against the rated voltage, %V 100 70 10 100 1,000 10,000 4 No. of operations, ×10 Tested sample: TQ2SA-12V, 6 pcs Operating speed: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method) Change of contact resistance (mounting by IRS method) 80 IRS 1 4.-(2) Electrical life (0.5 A 125 V AC resistive load) Ratio against the rated voltage, %V 20 30 Operate and release time, ms 0 100 50 1.0 0.8 0.6 0.4 0.2 –40 10 100 Frequency, MHz –9– 1,000 10 100 Frequency, MHz 1,000 ASCTB14E 201407-T TQ 10.-(1) Influence of adjacent mounting 10.-(2) Influence of adjacent mounting Tested sample: TQ2SA-12V, 6 pcs Tested sample: TQ2SA-12V, 5 pcs. Tested sample: TQ2SA-12V, 6 pcs. Deenergized condition Energized condition X 1000m/s2 Z' 1000m/s 2 1000m/s 2 Z 1000m/s 2 X' 1000m/s 2 Y' 10 ON ON Pick-up voltage 0 ON –10 Rate of change, % X' Y 1000m/s 2 Rate of change, % Z X Rate of change, % Z' Y Y' Rate of change, % 9. Malfunctional shock (single side stable) OFF OFF 10 Drop-out voltage 0 OFF –10 0 ON 10 Pick-up voltage 0 ON –10 ON OFF 10 Drop-out voltage 0 OFF –10 0 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch OFF 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch 11. Pulse dialing test 458 Ω 0.08 μF 48 V DC 0.08 μF TQ-SMD 3 relay 2 – 458 Ω Wire spring relay Change of contact resistance (mounting by IRS method) 100 100 90 90 Contact resistance, mΩ + Change of pick-up and drop-out voltage (mounting by IRS method) Ratio against the rated voltage, %V (35 mA 48 V DC wire spring relay load) Tested sample: TQ2SA-12V, 6 pcs. Circuit 80 Pick-up voltage 70 Max. 60 Min. 50 40 Drop-out voltage 30 Max. 20 Min. IRS 10 20 30 40 No. of operations, ×104 50 40 Max. 30 Min. 0 50 CAD Data External dimensions 14 .551 IRS 10 20 30 40 No. of operations, ×104 50 mark can be downloaded from: http://industrial.panasonic.com/ac/e/ PC board pattern (Bottom view) Standard PC board terminal (4.75) (.187) 60 10 The CAD data of the products with a DIMENSIONS (mm inch) 1. Standard PC board terminal and Self-clinching terminal CAD Data 70 20 10 0 80 2.54 .100 9 .354 10.16 .400 10-1.0 dia. 10-.039 dia. 5 +0.4 −0.2 .197 +.016 −.008 2.54 .100 7.62 .300 3.5 .138 0.25 .010 2.54 .100 0.5 .020 7.62 .300 0.25 .010 Tolerance: ±0.1 ±.004 Schematic (Bottom view) Self-clinching terminal (4.75) (.187) 14 .551 Single side stable 9 .354 5 +0.4 −0.2 .197 +.016 −.008 + 3.5 .138 0.25 .010 2.54 .100 0.5 .020 7.62 .300 General tolerance: ±0.3 ±.012 1 2 3 4 5 − 0.25 .010 1-coil latching − 1 2 3 4 2-coil latching 5 8 7 6 2 3 4 10 9 8 7 6 10 9 5 − − + + 10 9 1 + 8 7 6 Direction indication Direction indication Direction indication (Deenergized condition) (Reset condition) (Reset condition) –10– ASCTB14E 201407-T TQ 2. Surface-mount terminal CAD Data External dimensions (General tolerance: ±0.3 ±.012) Type 14 .551 Suggested mounting pad (Top view) (Tolerance: ±0.1 ±.004) 1 .039 9 .354 5.6 .220 SA type 2.54 .100 14 .551 9.56 .376 1 .039 9 .354 Max.7.5 .295 SL type 0.25 .010 4.9 .193 14 .551 9.56 .376 1 .039 9 .354 Max.7.5 .295 SS type 0.25 .010 4.9 .193 2.54 .100 1.84 .072 8.46 .333 7.62 .300 9.3±0.5 .366±.020 0.5 .020 2.54 .100 2.54 .100 2.94 .116 7.62 .300 11.5±0.5 .453±.020 0.5 .020 2.54 .100 2.54 .100 2.94 .116 7.62 .300 11.5±0.5 .453±.020 0.2 .008 0.5 .020 0.25 .010 4.9 .193 Schematic (Top view) Single side stable − 10 9 8 7 1-coil latching 6 + + 10 9 8 7 2-coil latching 6 10 9 2 3 4 5 7 1 2 3 4 5 1 6 − − + − 1 8 + 2 3 4 5 Direction indication Direction indication Direction indication (Deenergized condition) (Reset condition) (Reset condition) NOTES 1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Orientation (indicates PIN No.1) stripe (ii) SL, SS type mm inch 0.4 .016 Relay polarity bar 2.0 (Z type) 1.5 +0.1 0 dia. .079 .059 +.004 dia. 0 16.0 .630 TQ-SMD relays Note) *SS type Stopper (green) 2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions (i) SA type mm inch 0.4 .016 Relay polarity bar 2.0 (Z type) 1.5 +0.1 0 dia. .079 .059 +.004 dia. 0 4.0 .157 TQ-SMD relays 16.0 .630 12.3 24.0 ±0.3 .484 .945 ±.012 (10.1 .398)* Tape coming out direction (2) Dimensions of plastic reel mm inch A C B 21 dia. .827 dia. 2.0 .079 1.75 .069 14.6 .575 80 ±1 dia. 3.150 ±.039 dia. 11.5 .453 6.3 ±0.2 .248 ±.008 .575 11.5 .453 7.8 ±0.2 .307 ±.008 Stopper (gray) 1.75 4.0 .069 .157 14.6 2. Automatic insertion To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A: 9.8 N {1 kgf} or less Chucking pressure in the direction B: 9.8 N {1 kgf} or less Chucking pressure in the direction C: 9.8 N {1 kgf} or less 330 ±2 dia. 12.992 ±.079 dia. 12.3 24.0 ±0.3 .484 .945 ±.012 13 dia. .512 dia. Tape coming out direction –11– Please chuck the portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided. For general cautions for use, please refer to the “Cautions for use of Signal Relays” or “General Application Guidelines”. ASCTB14E 201407-T Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Panasonic: TQ2-L2-3V TQ2-4.5V TQ2-L2-5V TQ2-5V TQ2-12V TQ2-24V TQ4-24V TQ2SS-1.5V TQ4-6V TQ4-L2-12V TQ2-3V TQ4-3V TQ4-4.5V TQ2-L-5V TQ2H-5V TQ4-5V TQ2-6V TQ2-9V TQ2-L2-12V TQ4-12V TQ2-L2-24V TQ2-L-3V TQ4-L2-5V TQ2-L2-4.5V TQ2-L2-6V TQ2-L2-9V TQ2-48V TQ2-L-4.5V TQ4-L2-24V