5 mm Low profile, 2 Form C and 2 A (surfacemount type) relays
TQ RELAYS
FEATURES 1. Flat compact size 14.0 (L) × 9.0 (W) × 5.0 (H) mm .551 (L) × .354 (W) × .197 (H) inch 2. Nominal operating power: High sensitivity of 140mW (2 Form C single side stable type) 3. Suitable for SMD automatic insertion (SA type) With a height of 5.6 mm .220 inch, the relays meet JIS C 0806 specifications. 4. DIL terminal array enables use of IC sockets 5. Low thermal electromotive force (approx. 5 μV) [approx. 2 μV (surface-mount type)] 6. Latching types also available 7. Self-clinching terminal also available
RoHS compliant
8. A range of surface-mount types is also available SA: Low-profile surface-mount terminal type SL: High connection reliability surfacemount terminal type SS: Space saving surface-mount terminal type 9. M.B.B. contact types available
TYPICAL APPLICATIONS 1. Telephone-related equipment 2. Communications 3. Measurement equipment 4. OA equipment 5. Industrial machines
ORDERING INFORMATION TQ 2 Contact arrangement 2: 2 Form C Terminal shape Nil: Standard PC board terminal H: Self-clinching terminal SA: SA type SL: SL type SS: SS type Operating function Nil: Single side stable L: 1 coil latching L2: 2 coil latching MBB function Nil: Standard (B.B.M.) type 2M: 2M.B.B. type Nominal coil voltage (DC)* 1.5 (SMD only), 3, 4.5, 5, 6, 9, 12, 24, 48V Packing style Nil: Tube packing X: Tape and reel (picked from 1/2/3/4/5-pin side) Z: Tape and reel packing (picked from the 6/7/8/9/10-pin side) Notes: 1. *48 V coil type: Single side stable only 2. In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
–1–
ASCTB14E 201407-T
TQ TYPES ■ Standard PC board terminal and self-clinching terminal 1. Standard (B.B.M.) type 1) Standard PC board terminal Contact arrangement
Nominal coil voltage
2 Form C
3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC
Single side stable Part No. TQ2-3V TQ2-4.5V TQ2-5V TQ2-6V TQ2-9V TQ2-12V TQ2-24V TQ2-48V
1 coil latching Part No. TQ2-L-3V TQ2-L-4.5V TQ2-L-5V TQ2-L-6V TQ2-L-9V TQ2-L-12V TQ2-L-24V —
2 coil latching Part No. TQ2-L2-3V TQ2-L2-4.5V TQ2-L2-5V TQ2-L2-6V TQ2-L2-9V TQ2-L2-12V TQ2-L2-24V —
1 coil latching Part No. TQ2H-L-3V TQ2H-L-4.5V TQ2H-L-5V TQ2H-L-6V TQ2H-L-9V TQ2H-L-12V TQ2H-L-24V —
2 coil latching Part No. TQ2H-L2-3V TQ2H-L2-4.5V TQ2H-L2-5V TQ2H-L2-6V TQ2H-L2-9V TQ2H-L2-12V TQ2H-L2-24V —
Standard packing (2 Form C): Tube: 50 pcs.; Case: 1,000 pcs.
2) Self-clinching terminal Contact arrangement
Nominal coil voltage
2 Form C
3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC
Single side stable Part No. TQ2H-3V TQ2H-4.5V TQ2H-5V TQ2H-6V TQ2H-9V TQ2H-12V TQ2H-24V TQ2H-48V
Note: Types (“-3” to the end of part No.) designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered. However, please contact us if you need parts for use in low level load.
2. M.B.B. type 1) Standard PC board terminal Contact arrangement
Nominal coil voltage
2 Form C
3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
Single side stable Part No. TQ2-2M-3V TQ2-2M-4.5V TQ2-2M-5V TQ2-2M-6V TQ2-2M-9V TQ2-2M-12V TQ2-2M-24V
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
2) Self-clinching terminal Contact arrangement
Nominal coil voltage
2 Form C
3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
Single side stable Part No. TQ2H-2M-3V TQ2H-2M-4.5V TQ2H-2M-5V TQ2H-2M-6V TQ2H-2M-9V TQ2H-2M-12V TQ2H-2M-24V
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. Notes: 1. Latching types are available by request. Please consult us for details. 2. UL/CSA approved (UL file No.:E 43149, CSA file No.: LR26550) 3. Types (“-1” to the end of part No.) designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered. However, please contact us if you need parts for use in low level load and low thermal power.
–2–
ASCTB14E 201407-T
TQ ■ Surface-mount terminal 1) Tube packing Contact arrangement
Nominal coil voltage
2c
1.5 V DC 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC
Single side stable Part No. TQ2S-1.5V TQ2S-3V TQ2S-4.5V TQ2S-5V TQ2S-6V TQ2S-9V TQ2S-12V TQ2S-24V TQ2S-48V
1 coil latching Part No. TQ2S-L-1.5V TQ2S-L-3V TQ2S-L-4.5V TQ2S-L-5V TQ2S-L-6V TQ2S-L-9V TQ2S-L-12V TQ2S-L-24V —
2 coil latching Part No. TQ2S-L2-1.5V TQ2S-L2-3V TQ2S-L2-4.5V TQ2S-L2-5V TQ2S-L2-6V TQ2S-L2-9V TQ2S-L2-12V TQ2S-L2-24V —
: For each surface-mounted terminal identification, input the following letter. SA type: A, SL type: L, SS type: S Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
2) Tape and reel packing Contact arrangement
Nominal coil voltage
2 Form C
1.5 V DC 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48 V DC
Single side stable Part No. TQ2S-1.5V-Z TQ2S-3V-Z TQ2S-4.5V-Z TQ2S-5V-Z TQ2S-6V-Z TQ2S-9V-Z TQ2S-12V-Z TQ2S-24V-Z TQ2S-48V-Z
1 coil latching Part No. TQ2S-L-1.5V-Z TQ2S-L-3V-Z TQ2S-L-4.5V-Z TQ2S-L-5V-Z TQ2S-L-6V-Z TQ2S-L-9V-Z TQ2S-L-12V-Z TQ2S-L-24V-Z —
2 coil latching Part No. TQ2S-L2-1.5V-Z TQ2S-L2-3V-Z TQ2S-L2-4.5V-Z TQ2S-L2-5V-Z TQ2S-L2-6V-Z TQ2S-L2-9V-Z TQ2S-L2-12V-Z TQ2S-L2-24V-Z —
: For each surface-mounted terminal identification, input the following letter. SA type: A, SL type: L, SS type: S Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs. Note: Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available.
RATING ■ Standard PC board terminal and self-clinching terminal 1. Coil data [Standard (B.B.M.) type] 1) Single side stable (2 Form C) Nominal coil voltage 3
Drop-out voltage (at 20°C 68°F)
V DC
4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC 48
Pick-up voltage (at 20°C 68°F)
Nominal operating current [±10%] (at 20°C 68°F) 46.7 mA
75%V or less of nominal voltage* (Initial)
10%V or more of nominal voltage* (Initial)
V DC
31.1 28.1 23.3 15.5 11.7 8.3
mA mA mA mA mA mA
6.25 mA
Coil resistance [±10%] (at 20°C 68°F)
Nominal operating power
Max. applied voltage (at 20°C 68°F)
140 mW
150%V of nominal voltage
64.3 Ω 144.6 Ω 178 Ω 257 Ω 579 Ω 1,028 Ω 2,880 Ω 7,680
Ω
200 mW 300 mW
120%V of nominal voltage
Nominal operating power
Max. applied voltage (at 20°C 68°F)
100 mW
150%V of nominal voltage
2) 1 coil latching (2 Form C) Nominal coil voltage 3
Set voltage (at 20°C 68°F)
Reset voltage (at 20°C 68°F)
V DC
4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
75%V or less of nominal voltage* (Initial)
75%V or less of nominal voltage* (Initial)
Nominal operating current [±10%] (at 20°C 68°F) 33.3 mA 22.2 mA 20 mA 16.7 mA 11.1 mA 8.3 mA 6.3 mA
–3–
Coil resistance [±10%] (at 20°C 68°F) 90
Ω
202.5 Ω 250 Ω 360 Ω 810 Ω 1,440 Ω 3,840 Ω
150 mW
ASCTB14E 201407-T
TQ 3) 2 coil latching (2 Form C) Nominal coil voltage 3
Set voltage (at 20°C 68°F)
Reset voltage (at 20°C 68°F)
Nominal operating current [±10%] (at 20°C 68°F) Set coil Reset coil
V DC
66.7 mA
66.7 mA
4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC
44.4 mA 40 mA 33.3 mA 22.2 mA 16.7 mA
44.4 mA 40 mA 33.3 mA 22.2 mA 16.7 mA
12.5 mA
12.5 mA
24
75%V or less of nominal voltage* (Initial)
75%V or less of nominal voltage* (Initial)
V DC
Coil resistance [±10%] (at 20°C 68°F) Set coil 45
101.2 Ω 125 Ω 180 Ω 405 Ω 720 Ω 1,920
Reset coil
Ω
Ω
45
Max. applied voltage (at 20°C 68°F)
Set coil
Reset coil
200 mW
200 mW
150%V of nominal voltage
300 mW
300 mW
120%V of nominal voltage
Ω
101.2 Ω 125 Ω 180 Ω 405 Ω 720 Ω 1,920
Nominal operating power
Ω
[M.B.B. type] Nominal coil voltage 3
Drop-out voltage (at 20°C 68°F)
Pick-up voltage (at 20°C 68°F)
V DC
4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
80%V or less of nominal voltage* (Initial)
10%V or more of nominal voltage* (Initial)
Nominal operating current [±10%] (at 20°C 68°F) 66.7 mA
Coil resistance [±10%] (at 20°C 68°F)
Nominal operating power
Max. applied voltage (at 20°C 68°F)
200 mW
150%V of nominal voltage
45 Ω 101 Ω 125 Ω 180 Ω 405 Ω 720 Ω 2,880 Ω
44.4 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA
*Pulse drive (JIS C 5442-1986)
2. Specifications Characteristics Contact
Rating
Item Arrangement Initial contact resistance, max. Contact material Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1
Specifications 2 Form C, 2 Form D (M.B.B.) Max. 50mΩ (By voltage drop 6 V DC 1A) Ag+Au clad 1 A 30 V DC, 0.5 A 125 V AC (resistive load) 30 W (DC), 62.5 V A (AC) (resistive load) 110 V DC, 125 V AC 1A 10μA 10mV DC
Single side stable Nominal operating power 1 coil latching 2 coil latching
Standard (B.B.M) type: 140 mW (3 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC) M.B.B. type: 200 mW 100 mW (3 to 12 V DC), 150 mW (24 V DC) 200 mW (3 to 12 V DC), 300 mW (24 V DC)
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
Between open contacts Electrical characteristics
Breakdown voltage (Initial)
Between contact and coil Between contact sets Temperature rise (at 20°C 68°F) Operate time [Set time] (at 20°C 68°F) Release time [Reset time] (at 20°C 68°F)
Mechanical characteristics
Expected life
Conditions
Shock resistance
Functional Destructive
Functional Destructive Mechanical (at 180 cpm)
Vibration resistance
Electrical (at 20 cpm)
Conditions for operation, transport and storage*2
Max. operating speed (at rated load) Unit weight
Standard (B.B.M) type: 750 Vrms for 1min. (Detection current: 10 mA), M.B.B. type: 300 Vrms for 1 min. (Detection current: 10 mA) 1,000 Vrms for 1min. (Detection current: 10 mA) 1,000 Vrms for 1min. (Detection current: 10 mA) Max. 50°C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.) Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 490 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5 mm Standard (B.B.M) type: Min. 108, M.B.B. type: Min. 107 Standard (B.B.M) type: Min. 2×105 (1 A 30 V DC resistive), Min. 105 (0.5 A 125 V AC resistive) M.B.B. type: Min. 105 (1 A 30 V DC resistive) Standard (B.B.M) type: Ambient temperature: –40°C to +70°C –40°F to +158°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) M.B.B. type: Ambient temperature: –40°C to +50°C –40°F to +122°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 cpm Approx. 1.5 g .053 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load switching (10V DC, 10mA max. level). *2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
–4–
ASCTB14E 201407-T
TQ ■ Surface-mount terminal 1. Coil data 1) Single side stable Nominal operating current (at 20°C 68°F)
Coil resistance [±10%] (at 20°C 68°F)
1.5 V DC
93.8 mA
16
3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
46.7 mA 31 mA 28.1 mA 23.3 mA 15.5 mA 11.7 mA 8.3 mA
64.3 Ω 145 Ω 178 Ω 257 Ω 579 Ω 1,028 Ω 2,880 Ω
Nominal coil voltage
48
Pick-up voltage (at 20°C 68°F)
75%V or less of nominal voltage* (Initial)
Drop-out voltage (at 20°C 68°F)
10%V or more of nominal voltage* (Initial)
V DC
6.3 mA
7,680
Nominal operating power
Max. applied voltage (at 20°C 68°F)
140 mW
150%V of nominal voltage
Ω
Ω
200 mW 300 mW
120%V of nominal voltage
Nominal operating power
Max. applied voltage (at 20°C 68°F)
70 mW
150%V of nominal voltage
2) 1 coil latching
1.5 V DC
Nominal operating current (at 20°C 68°F) 46.9 mA
3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC
23.3 mA 15.6 mA 14 mA 11.7 mA 7.8 mA 5.8 mA
Nominal coil voltage
24
Set voltage (at 20°C 68°F)
75%V or less of nominal voltage* (Initial)
Reset voltage (at 20°C 68°F)
75%V or less of nominal voltage* (Initial)
V DC
4.2 mA
Coil resistance [±10%] (at 20°C 68°F) 32
Ω
128.6 Ω 289.3 Ω 357 Ω 514 Ω 1,157 Ω 2,057 Ω 5,760
Ω
100 mW
3) 2 coil latching Nominal coil voltage 1.5 V DC 3 V DC 4.5 V DC 5 V DC 6 V DC 9 V DC 12 V DC 24 V DC
Set voltage (at 20°C 68°F)
75%V or less of nominal voltage* (Initial)
Reset voltage (at 20°C 68°F)
75%V or less of nominal voltage* (Initial)
Nominal operating current (at 20°C 68°F) Set coil Reset coil 93.8 mA 93.8 mA 46.7 mA 31 mA 28.1 mA 23.3 mA 15.5 mA 11.7 mA 8.3 mA
46.7 mA 31 mA 28.1 mA 23.3 mA 15.5 mA 11.7 mA 8.3 mA
Coil resistance [±10%] (at 20°C 68°F) Set coil 16 Ω
Reset coil 16 Ω
64.3 Ω 145 Ω 178 Ω 257 Ω 579 Ω 1,028 Ω 2,880 Ω
64.3 Ω 145 Ω 178 Ω 257 Ω 579 Ω 1,028 Ω 2,880 Ω
Nominal operating power Set coil
Reset coil
140 mW
140 mW
200 mW
200 mW
Max. applied voltage (at 20°C 68°F)
150%V of nominal voltage
*Pulse drive (JIS C 5442-1986)
–5–
ASCTB14E 201407-T
TQ 2. Specifications Characteristics Contact
Rating
Item Arrangement Initial contact resistance, max. Contact material Nominal switching capacity Max. switching power Max. switching voltage Max. switching current Min. switching capacity (Reference value)*1 Nominal operating power
Single side stable 1 coil latching 2 coil latching
Insulation resistance (Initial)
Electrical characteristics
1,000 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage (Initial)
Between open contacts Between contacts and coil
1,500 V (10×160μs) (FCC Part 68) 2,500 V (2×10μs) (Bellcore) Max. 50°C (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10μs.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5 mm Min. 108 (at 180 cpm) Min. 105 (2 A 30 V DC resistive), Min. 2×105 (1 A 30 V DC resistive), Min. 105 (0.5 A 125 V AC resistive) (at 20 cpm) Ambient temperature: –40°C to +85°C –40°F to +185°F, Max. –40°C to +70°C (2A) Max. –40°F to +158°F (2A); Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 cpm Approx. 2 g .071 oz
Release time [Reset time] (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical
Shock resistance
Conditions
Electrical Conditions for operation, transport and storage*2 Max. operating speed (at rated load)
Unit weight
140 mW (1.5 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC) 70 mW (1.5 to 12 V DC), 100 mW (24 V DC) 140 mW (1.5 to 12 V DC), 200 mW (24 V DC) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
Between open contacts Between contact and coil Between contact sets
Operate time [Set time] (at 20°C 68°F)
Expected life
10μA 10mV DC
Breakdown voltage (Initial)
Temperature rise (at 20°C 68°F)
Mechanical characteristics
Specifications 2 Form C Max. 75 mΩ (By voltage drop 6 V DC 1A) AgNi type+Au clad 2 A 30 V DC, 0.5 A 125 V AC (resistive load) 60 W (DC), 62.5 VA (AC) (resistive load) 220 V DC, 125 V AC 2A
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (TX/TX-S/TX-D relay AgPd contact type are available for low level load switching [10V DC, 10mA max. level]) *2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
–6–
ASCTB14E 201407-T
TQ REFERENCE DATA ■ Standard PC board terminal and self-clinching terminal 1. Maximum switching capacity
2. Life curve
3. Mechanical life
1.0
0.5 0.4 0.3
Ratio against the rated voltage, %V
DC load (cosϕ=1) AC load (cosϕ=1)
No. of operations, ×104
Switching current, A
Tested sample: TQ2-12V, 10 pcs.
30 V DC resistive load
100
125 V AC resistive load 10
0.2
30
0
100 200 Switching voltage,V
100 90 80
Pick-up voltage Max. Min.
70 60 50 40 Drop-out voltage
30
Max.
20 Min.
10 0
0.5 1.0 Switching current, A
10
100 1,000 10,000 No. of operations, ×104
4.-(1) Electrical life (DC load)
4.-(2) Electrical life (AC load)
Tested sample: TQ2-12V, 6 pcs. Condition: 1 A 30 V DC resistive load, 20 cpm
Tested sample: TQ2-12V, 6 pcs. Condition: 0.5 A 125 V AC resistive load, 20 cpm
Change of contact resistance 100
90
90
Pick-up voltage
Max.
70
Min.
60 50 40
Drop-out voltage Max.
30 20
Min.
80 70 60 50
Max.
40 Min.
30 20
10
10 0
5
10 15 No. of operations, ×104
20
Change of contact resistance
0
5
10 15 No. of operations, ×104
50 40
Max.
30
Min.
Max. Min.
60 50 40
Drop-out voltage
Max.
30 Min.
20 10 0
5 No. of operations, ×104
10
Tested sample: TQ2-12V, 5 pcs.
Temperature rise, C°
60
Pick-up voltage
70
6. Ambient temperature characteristics
70
70
80
Tested sample: TQ2-12V Measured portion: Inside the coil Ambient temperature: 30°C 86°F
90 80
20
90
5. Coil temperature rise (2C)
100 Contact resistance, mΩ
100
Variation ratio,%
80
Change of pick-up and drop-out voltage Ratio against the rated voltage, %V
100 Contact resistance, mΩ
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage
Nominal coil voltage 3 to 12 V DC type 24 V DC type
60
1A
50
40 30 Drop-out 20 voltage
x x
10 40
1A 0A
-40 -20
0 20 40
30
-10
20
Pick-up voltage 60 80 Ambient temperature,°C
-20
20 10
10 0
5 No. of operations, ×104
0
10
7.-(1) High-frequency characteristics (Isolation)
-30 -40 100 110 120 130 140 150 Coil applied voltage, %V
7.-(2) High-frequency characteristics (Insertion loss)
8. Malfunctional shock (single side stable) Tested sample: TQ2-12V, 6 pcs.
,
Insertion loss, dB
Isolation, dB
,Z XX
100
50
Z Y, Y
Z 980m/s2
980m/s2 , Z
980m/s2 , X
0.8
980m/s2 , Y
0.2 1,000
980m/s2 1.0
0.4
100 Frequency, MHz
Deenergized condition Energized condition
X
0.6
10
Y 980m/s2
0
10
100 Frequency, MHz
–7–
1,000
ASCTB14E 201407-T
TQ 9.-(1) Influence of adjacent mounting
9.-(2) Influence of adjacent mounting
10. Contact reliability (1 mA 5 V DC resistive load)
10
ON
Pick-up voltage
Rate of change, % Rate of change, %
Rate of change, % Rate of change, %
Tested sample: TQ2-12V Condition: Detection level 10 W
ON
0 –10 ON OFF OFF
10
Drop-out voltage
0 OFF
–10 0
10
Pick-up voltage
ON
70.0 50.0 30.0
0 –10
ON
10
10.0 5.0
OFF
Drop-out voltage
2.0 1.0 0.5
0 OFF
–10 5 .197 Inter-relay distance
, mm inch
m=2.15 μ=2.7×107 95% reliability limit = 7.6×106 (Weibull probability paper)
0.2 0.1 1.0
OFF
0
5 .197 Inter-relay distance
ON
F(t), % 99.9 99.0 95.0
10
100
No. of operations, ×106
, mm inch
11. Actual load test (35 mA 48 V DC wire spring relay load) Change of pick-up and drop-out voltage
220Ω
57 V DC
220Ω
100
90
90
80 Pick-up voltage
70
Max. Min.
60 50 40 30
Drop-out voltage Max. Min.
20 10
12. 0.1 A 53 V DC resistive load test Change of pick-up and drop-out voltage
80 70 60 50 40
Max.
30
Min.
20 10
0
Wire spring relay Circuit diagram
10
20 30 40 No. of operations, ×104
50
0
10
20 30 40 No. of operations, ×104
50
Change of contact resistance
100
100
90 80
Pick-up voltage Max. Min.
70 60 50 40 30
Drop-out voltage
20
Max. Min.
10 0
500
1,000
1,500
Contact resistance, mΩ
Ratio against the rated voltage, %V
100
Ratio against the rated voltage, %V
20Hz
Change of contact resistance
Contact resistance, mΩ
Circuit
90 80 70 60
Max.
50 40 30
Min.
20 10
2,000
0
500
No. of operations, ×104
1,000 1,500 2,000 No. of operations, ×104
13. Distribution of M.B.B. time Tested sample: TQ2-2M-5V, 85 pcs.
50 40 30 20
26 19 15
21
Terminal Nos. 2-3-4: ON − x: 105.6 μs 3σn-1: 163.8 μs Min.: 23 μs Max.: 243 μs Terminal Nos. 7-8-9: ON − x: 115.6 μs 3σn-1: 167.3 μs 30 Min.: 35 μs Max.: 254 μs 19
60
41 40
35 31
30
27
20
17
12
11 10
Terminal Nos. 2-3-4: OFF − x: 71.6 μs 3σn-1: 127.1 μs Min.: 17 μs Max.: 187 μs Terminal Nos. 7-8-9: OFF − x: 80.7 μs 3σn-1: 156.7 μs Min.: 29 μs Max.: 298 μs
50
10
6
10
200
250
300
350 μs max.
100 150
~
150
2
50
~
100
1
10
~
~
50
0
7 4
~
~
300 μs min.
200 250
300 μs min.
50
100
150
200
250
300
350 μs max.
~
~
4 200 250
~
100 150
~
50 ~
10 ~
0
~
2
–8–
~
60
ASCTB14E 201407-T
TQ ■ Surface-mount terminal 1. Maximum switching capacity
2. Life curve
3. Mechanical life (mounting by IRS method)
Ratio against the rated voltage, %V
Tested sample: TQ2SA-12V, 10 pcs.
No. of operations, × 104
Switching current, A
3.0 2.0
100
DC resistive load
1.0 AC resistive load
0.5 0.4 0.3
50 30
125V AC resistive load
30V DC resistive load
20 10
0.2
100 90 80 Pick-up voltage
70
Max.
60
Min.
50 40 Drop-out voltage
30
Max.
20 Min.
10 0
50 100 200 300 Contact voltage, V
0
1.0 2.0 Switching current, A
4.-(1) Electrical life (2 A 30 V DC resistive load) Tested sample: TQ2SA-12V, 6 pcs. Operating speed: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method)
90
Pick-up voltage
Max. Min.
60 50 40
Drop-out voltage
30 Max.
20
IRS 1
2
70 60 50
Max.
40 Min.
30
0
50
Max.
40 Min.
30
IRS 1
2
Coil voltage DC 12V type DC 48V type
0A
50 2A
40
0A
30
4
5
6
7
8
0
9 10
No. of operations, ×104
7. Ambient temperature characteristics
0
8.-(1) High-frequency characteristics (Isolation)
IRS 1
2
3 4 5 6 7 8 9 10 No. of operations, ×104
Operate time Release time 4 Max. Min.
3
2 Max. Min.
70
80
90 100 110 120 Coil applied voltage, %V
8.-(2) High-frequency characteristics (Insertion loss)
40
20
Pick-up voltage x
Drop-out voltage 20 40 60 80 Ambient temperature, °C –20
Isolation, dB
–40 –20
Rate of change, %
Tested sample: TQ2SA-12V, 5 pcs.
Min.
0
100 110 120 130 140 150 Coil applied voltage, %V
Insertion loass, dB
3
Max.
20
1
10
2
Drop-out voltage
30
5
2A
20
10 IRS 1
40
0
3 4 5 6 7 8 9 10 No. of operations, ×104
20
0
Min.
50
Tested sample: TQ2SA-12V, 6 pcs.
60
Max.
60
6. Operate/release time
Temperature rise, °C
60
Pick-up voltage
70
10
70
70
80
Tested sample: TQ2SA-12V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F
90 80
90
5. Coil temperature rise
100 Contact resistance, mΩ
80
10
3 4 5 6 7 8 9 10 No. of operations, ×104
Change of contact resistance (mounting by IRS method)
100
20
Min.
10 0
Contact resistance, mΩ
100
90
Ratio against the rated voltage, %V
100
70
10 100 1,000 10,000 4 No. of operations, ×10
Tested sample: TQ2SA-12V, 6 pcs Operating speed: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method)
Change of contact resistance (mounting by IRS method)
80
IRS 1
4.-(2) Electrical life (0.5 A 125 V AC resistive load)
Ratio against the rated voltage, %V
20 30
Operate and release time, ms
0
100
50
1.0 0.8 0.6 0.4 0.2
–40 10
100 Frequency, MHz
–9–
1,000
10
100 Frequency, MHz
1,000
ASCTB14E 201407-T
TQ 10.-(1) Influence of adjacent mounting
10.-(2) Influence of adjacent mounting
Tested sample: TQ2SA-12V, 6 pcs
Tested sample: TQ2SA-12V, 5 pcs.
Tested sample: TQ2SA-12V, 6 pcs.
Deenergized condition Energized condition
X 1000m/s2
Z' 1000m/s 2
1000m/s 2 Z
1000m/s 2 X' 1000m/s 2 Y'
10
ON
ON
Pick-up voltage 0 ON
–10
Rate of change, %
X' Y 1000m/s 2
Rate of change, %
Z X
Rate of change, %
Z' Y Y'
Rate of change, %
9. Malfunctional shock (single side stable)
OFF OFF
10 Drop-out voltage 0
OFF
–10 0
ON
10 Pick-up voltage 0
ON –10 ON OFF
10 Drop-out voltage
0
OFF –10 0
1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
OFF 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
11. Pulse dialing test
458 Ω
0.08 μF 48 V DC
0.08 μF
TQ-SMD 3 relay 2
–
458 Ω Wire spring relay
Change of contact resistance (mounting by IRS method)
100
100
90
90 Contact resistance, mΩ
+
Change of pick-up and drop-out voltage (mounting by IRS method) Ratio against the rated voltage, %V
(35 mA 48 V DC wire spring relay load) Tested sample: TQ2SA-12V, 6 pcs. Circuit
80 Pick-up voltage
70
Max.
60
Min.
50 40
Drop-out voltage
30
Max.
20
Min.
IRS
10
20 30 40 No. of operations, ×104
50 40
Max.
30
Min.
0
50
CAD Data
External dimensions 14 .551
IRS
10
20 30 40 No. of operations, ×104
50
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
PC board pattern (Bottom view)
Standard PC board terminal (4.75) (.187)
60
10
The CAD data of the products with a DIMENSIONS (mm inch) 1. Standard PC board terminal and Self-clinching terminal
CAD Data
70
20
10 0
80
2.54 .100
9 .354
10.16 .400
10-1.0 dia. 10-.039 dia.
5 +0.4 −0.2 .197 +.016 −.008
2.54 .100 7.62 .300
3.5 .138 0.25 .010
2.54 .100
0.5 .020
7.62 .300
0.25 .010
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
Self-clinching terminal (4.75) (.187)
14 .551
Single side stable
9 .354
5 +0.4 −0.2 .197 +.016 −.008
+
3.5 .138 0.25 .010
2.54 .100
0.5 .020
7.62 .300
General tolerance: ±0.3 ±.012
1
2
3
4
5
−
0.25 .010
1-coil latching −
1
2
3
4
2-coil latching 5
8
7
6
2
3
4
10 9
8
7
6
10 9
5
− −
+
+ 10 9
1
+
8
7
6
Direction indication
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
(Reset condition)
–10–
ASCTB14E 201407-T
TQ 2. Surface-mount terminal CAD Data
External dimensions (General tolerance: ±0.3 ±.012)
Type
14 .551
Suggested mounting pad (Top view) (Tolerance: ±0.1 ±.004) 1 .039
9 .354 5.6 .220
SA type 2.54 .100
14 .551
9.56 .376
1 .039
9 .354 Max.7.5 .295
SL type
0.25 .010
4.9 .193
14 .551
9.56 .376
1 .039
9 .354 Max.7.5 .295
SS type
0.25 .010
4.9 .193
2.54 .100
1.84 .072 8.46 .333
7.62 .300 9.3±0.5 .366±.020
0.5 .020
2.54 .100
2.54 .100
2.94 .116
7.62 .300 11.5±0.5 .453±.020
0.5 .020
2.54 .100
2.54 .100
2.94 .116
7.62 .300 11.5±0.5 .453±.020
0.2 .008
0.5 .020
0.25 .010
4.9 .193
Schematic (Top view) Single side stable −
10 9
8
7
1-coil latching
6
+
+
10 9
8
7
2-coil latching 6
10 9
2
3
4
5
7
1
2
3
4
5
1
6
− −
+
− 1
8
+
2
3
4
5
Direction indication
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
(Reset condition)
NOTES 1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Orientation (indicates PIN No.1) stripe
(ii) SL, SS type mm inch
0.4 .016
Relay polarity bar 2.0 (Z type) 1.5 +0.1 0 dia. .079 .059 +.004 dia. 0
16.0 .630
TQ-SMD relays
Note) *SS type Stopper (green)
2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions (i) SA type mm inch
0.4 .016
Relay polarity bar 2.0 (Z type) 1.5 +0.1 0 dia. .079 .059 +.004 dia. 0
4.0 .157
TQ-SMD relays
16.0 .630
12.3 24.0 ±0.3 .484 .945 ±.012 (10.1 .398)*
Tape coming out direction
(2) Dimensions of plastic reel mm inch
A
C
B
21 dia. .827 dia. 2.0 .079
1.75 .069 14.6 .575
80 ±1 dia. 3.150 ±.039 dia.
11.5 .453
6.3 ±0.2 .248 ±.008
.575
11.5 .453
7.8 ±0.2 .307 ±.008
Stopper (gray)
1.75 4.0 .069 .157 14.6
2. Automatic insertion To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A: 9.8 N {1 kgf} or less Chucking pressure in the direction B: 9.8 N {1 kgf} or less Chucking pressure in the direction C: 9.8 N {1 kgf} or less
330 ±2 dia. 12.992 ±.079 dia.
12.3 24.0 ±0.3 .484 .945 ±.012
13 dia. .512 dia.
Tape coming out direction
–11–
Please chuck the portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided. For general cautions for use, please refer to the “Cautions for use of Signal Relays” or “General Application Guidelines”.
ASCTB14E 201407-T
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic: TQ2-L2-3V TQ2-4.5V TQ2-L2-5V TQ2-5V TQ2-12V TQ2-24V TQ4-24V TQ2SS-1.5V TQ4-6V TQ4-L2-12V TQ2-3V TQ4-3V TQ4-4.5V TQ2-L-5V TQ2H-5V TQ4-5V TQ2-6V TQ2-9V TQ2-L2-12V TQ4-12V TQ2-L2-24V TQ2-L-3V TQ4-L2-5V TQ2-L2-4.5V TQ2-L2-6V TQ2-L2-9V TQ2-48V TQ2-L-4.5V TQ4-L2-24V