Preview only show first 10 pages with watermark. For full document please download

Tq Smd Relays Low-profile

   EMBED


Share

Transcript

TQ SMD TESTING LOW-PROFILE SURFACE-MOUNT RELAY TQ SMD RELAYS FEATURES 14 .551 9 .354 5.6 .220 mm inch • Low-profile: 6 mm .236 inch (Tape height: max. 6.5 mm .256 inch) • Tape and reel package is available as standard packing style • Surge withstand between contacts and coil: 2,500 V • Breakdown voltage between contacts and coil: 1,500 V • Capacity: 2 A • High sensitivity: 2 Form C; 140 mW power consumption (Single side stable type) SPECIFICATIONS Contact Characteristics Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Rating Max. switching voltage Max. switching current Min. switching capacity ❇1 Single side stable Nominal operating power 1 coil latching 2 coil latching Expected life (min. operations) Mechanical (at 180 cpm) 2 A 30 V DC resistive Electrical 1 A 30 V DC (at 20 cpm) resistive 0.5 A 125 V AC resistive 2 Form C 75 mΩ Gold-clad silver alloy 2 A 30 V DC, 0.5 A 125 V AC 60 W, 62.5 VA 220 V DC, 125 V AC 2A 10 µA 10 mV DC 140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 300 mW (48 V DC) 70 mW (1.5 to 12 V DC) 100 mW (24 V DC) 140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 108 Initial insulation resistance*1 Between open contacts Initial breakdown Between contact sets voltage Between contact and coil Between open contacts Initial surge (10×160 µs) voltage Between contacts and coil (2×10 µs) Temperature rise*2 (at 20°C) Operate time [Set time]*3 (at 20°C) Release time [Reset time]*4 (at 20°C) Functional*5 Shock resistance Destructive*6 Functional*7 105 Vibration resistance Destructive 2×105 105 Note: ❇1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (SX relays are available for low level load switching [10 µA 1 mV DC – 10 mA 10 V DC]) Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight Ambient temperature Humidity Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 2 A. *3 Nominal voltage applied to the coil, excluding contact bounce time. *4 Nominal voltage applied to the coil, excluding contact bounce time without diode. *5 Half-wave pulse of sine wave: 6 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. Min. 1,000 MΩ (at 500 V DC) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) 1,500 V (FCC Part 68) 2,500 V (Telcordia) Max. 50°C Max. 4 ms (Approx. 2 ms) [Max. 4 ms (Approx. 2 ms)] Max. 4 ms (Approx. 1 ms) [Max. 4 ms (Approx. 2 ms)] Min. 750 m/s2 {75 G} Min. 1,000 m/s2 {100 G} 200 m/s2 {20G}, 10 to 55 Hz at double amplitude of 3.3 mm 294 m/s2 {30G}, 10 to 55 Hz at double amplitude of 5 mm –40°C to +85°C*3 –40°F to +185°F 5 to 85% R.H. Approx. 2 g .071 oz TQ SMD ORDERING INFORMATION Ex. TQ Contact arrangement 2: 2 Form C 2 – SA Surface-mount availability SA: Standard surface-mount SA: terminal type SL : High connection reliability SA: surface-mount terminal type SS: Space saving surfaceSA: mount terminal type L – 3V – Z Operating function Coil voltage (DC) Nil: Single side stable L: 1 coil latching L2: 2 coil latching 1.5, 3, 4.5, 5, 6, 9, 12, 24, 48* V Packing style Nil: Tube packing Z: Tape and reel packing (picked from the 6/7/8/9/10-pin side) *48 V coil type: Single side stable only Notes: 1. Tape and reel (picked from 1/2/3/4/5-pin side) is also available by request. Part No. suffix “-X” is needed when ordering. (ex.) TQ2SA-3V-X 2. Tape and reel packing symbol “-Z” or “-X” are not marked on the relay. TYPES 1. Single side stable Nominal voltage, V DC Pick-up voltage, V DC (max.) Drop-out voltage, V DC (min.) 1.5 3 4.5 5 6 9 12 24 48 1.13 2.25 3.38 3.75 4.5 6.75 9 18 36 0.15 0.3 0.45 0.5 0.6 0.9 1.2 2.4 4.8 Nominal voltage, V DC Set voltage, V DC (max.) Reset voltage, V DC (max.) 1.5 3 4.5 5 6 9 12 24 1.13 2.25 3.38 3.75 4.5 6.75 9 18 1.13 2.25 3.38 3.75 4.5 6.75 9 18 Part No. Nominal voltage, V DC Set voltage, V DC (max.) Reset voltage, V DC (max.) TQ2S❍-L2-1.5 V TQ2S❍-L2-3 V TQ2S❍-L2-4.5 V TQ2S❍-L2-5 V TQ2S❍-L2-6 V TQ2S❍-L2-9 V TQ2S❍-L2-12 V TQ2S❍-L2-24 V 1.5 3 4.5 5 6 9 12 24 1.13 2.25 3.38 3.75 4.5 6.75 9 18 1.13 2.25 3.38 3.75 4.5 6.75 9 18 Part No. TQ2S❍-1.5 V TQ2S❍-3 V TQ2S❍-4.5 V TQ2S❍-5 V TQ2S❍-6 V TQ2S❍-9 V TQ2S❍-12 V TQ2S❍-24 V TQ2S❍-48 V Nominal operating current, mA (±10%) 93.8 46.7 31 28.1 23.3 15.5 11.7 8.3 6.3 Coil resistance, Ω (±10%) Nominal operating power, mW Max. allowable voltage, V DC 16 64.3 145 178 257 579 1,028 2,880 7,680 140 140 140 140 140 140 140 200 300 2.2 4.5 6.7 7.5 9 13.5 18 36 57.6 Coil resistance, Ω (±10%) Nominal operating power, mW Max. allowable voltage, V DC 32 128.6 289.3 357 514 1,157 2,057 5,760 70 70 70 70 70 70 70 100 2.2 4.5 6.7 7.5 9 13.5 18 36 Coil resistance, Ω (±10%) Nominal operating power, mW Max. allowable voltage, V DC 16 64.3 145 178 257 579 1,028 2,880 140 140 140 140 140 140 140 200 2.2 4.5 6.7 7.5 9 13.5 18 36 2. 1 coil latching Part No. TQ2S❍-L-1.5 V TQ2S❍-L-3 V TQ2S❍-L-4.5 V TQ2S❍-L-5 V TQ2S❍-L-6 V TQ2S❍-L-9 V TQ2S❍-L-12 V TQ2S❍-L-24 V Nominal operating current, mA (±10%) 46.9 23.3 15.6 14 11.7 7.8 5.8 4.2 3. 2 coil latching Nominal operating current, mA (±10%) 93.8 46.7 31 28.1 23.3 15.5 11.7 8.3 ❍: For each surface-mounted terminal variation, input the following letter. SA type: A, SL type: L, SS type: S Notes: 1. Specified value of the pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse. 2. Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. Tape and reel: 500 pcs.; Case: 1,000 pcs. 3. In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. TQ SMD DIMENSIONS mm inch SA type 9 .354 14 .551 2.54 .100 0.5 .020 0.25 .010 4.9 .193 5.6 .220 Recommendable mounting pad (Top view) SA type 1 .039 7.62 .300 11.5±0.5 .453±.020 0.2 .008 Schematic (Top view) •Single side stable (Deenergized condition) − 10 9 8 7 6 1 3 4 5 2.54 .100 + 2 .079 2.94 .116 9.56 .376 SL type 2 Direction indication* *Orientation stripe located on top of relay. 9 .354 14 .551 0.25 .010 4.9 .193 Max. 7.5 .295 2.54 .100 0.3 .012 For glue-pad •1-coil latching (Reset condition) 14 .551 + SL type 7.62 .300 11.5±0.5 .453±.020 0.5 .020 1 .039 2.54 .100 9.56 .376 1 3 4 5 2 *Orientation stripe located on top of relay. SS type 7.62 .300 9.3±0.5 ±.020 0.5 .020 6 •2-coil latching (Reset condition) 0.25 .010 4.9 .193 Max. 7.5 .295 7 Direction indication* 9 .354 14 .551 8 − 2.54 .100 2.94 .116 SS type 10 9 1 .039 General tolerance: ±0.3 ±.012 10 9 8 7 + 2.54 .100 − + 1.84 .072 1 8.46 .333 6 − 2 3 4 5 Direction indication* *Orientation stripe located on top of relay. Tolerance: ±0.1 ±.004 REFERENCE DATA 1. Maximum switching capacity 2. Life curve 3. Mechanical life (mounting by IRS method) Ratio against the rated voltage, %V Tested sample: TQ2SA-12V, 10 pcs. No. of operations, × 104 Switching current, A 3.0 2.0 100 DC resistive load 1.0 AC resistive load 0.5 0.4 0.3 50 30 125V AC resistive load 30V DC resistive load 20 10 0.2 100 90 80 Pick-up voltage 70 Max. 60 Min. 50 40 Drop-out voltage 30 Max. 20 Min. 10 0 20 30 0 50 100 200 300 Contact voltage, V 0 1.0 2.0 Switching current, A IRS 1 10 100 1,000 10,000 4 No. of operations, ×10 4.-(2) Electrical life (0.5 A 125 V AC resistive load) Tested sample: TQ2SA-12V, 6 pcs. Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method) Tested sample: TQ2SA-12V, 6 pcs Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method) Change of contact resistance (mounting by IRS method) 100 90 90 80 Pick-up voltage 70 60 Max. Min. 50 40 Drop-out voltage 30 Max. 20 Min. 10 0 IRS 1 2 3 4 5 6 7 8 9 10 No. of operations, ×104 100 80 70 60 50 Max. 40 Min. 30 20 90 80 Pick-up voltage 70 60 Max. Min. 50 40 Drop-out voltage 30 Max. 20 Min. 10 10 0 Ratio against the rated voltage, %V 100 Contact resistance, mΩ Ratio against the rated voltage, %V 4.-(1) Electrical life (2 A 30 V DC resistive load) IRS 1 2 3 4 5 6 7 8 9 10 No. of operations, ×104 0 IRS 1 All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 2 3 4 5 6 7 8 9 10 No. of operations, ×104 TQ SMD Change of contact resistance (mounting by IRS method) 5. Coil temperature rise 6. Operate/release time Tested sample: TQ2SA-12V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F Tested sample: TQ2SA-12V, 6 pcs. 100 70 70 60 50 Max. 40 Min. 30 60 5 2A Coil voltage DC 12V type DC 48V type 0A 50 2A 40 0A 30 20 20 Operate and release time, ms 80 Temperature rise, °C Contact resistance, mΩ 90 0 IRS 1 2 3 4 5 6 7 8 No. of operations, ×10 0 9 10 4 Max. Min. 3 2 Max. Min. 1 10 10 Operate time Release time 0 100 110 120 130 140 150 Coil applied voltage, %V 4 70 80 90 100 110 120 Coil applied voltage, %V 8. Distribution of set and reset voltage 9. Ambient temperature characteristics Tested sample: TQ2SA-12V, 50 pcs. Tested sample: TQ2SA-L-12V, 30 pcs. Tested sample: TQ2SA-12V, 5 pcs. Set voltage Reset voltage ; @   @   ; @   ; ;@;@;@;@;@;@;@ 25 0 Quantity –40 –20 15 0 ; ; ;;;;; ;;;;; 10 20 ;;;;; ;;;;;; ; ; ;@;@;@;@;@;@;@ ; @   @   ; @   ; Drop-out voltage 20 ;; 30 Quantity ;; 30 Pick-up voltage 10 Rate of change, % 7. Distribution of pick-up and drop out voltage 40 20 Pick-up voltage x Drop-out voltage 20 40 60 80 Ambient temperature, °C –20 5 0 10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V –40 10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V 10. Distribution of contact resistance 11.-(1) High-frequency characteristics 11.-(2) High-frequency characteristics Tested sample: TQ2SA-5V, 30 pcs. (30 × 4 contacts) Isolation characteristics Insertion loss characteristics 50 10 9 8 7 6 1 2 3 4 5 Isolation, dB Terminal Nos. 2-3, 8-9 ; Quantity (TOP VIEW) ;;;;;;;; ;;;;;; 30 20 10 0 20 Insertion loass, dB ;;;;;;;; ;;; Terminal Nos. 3-4, 7-8 ;;; 40 – + 100 50 0.4 0.2 10 30 40 50 Contact resistance, mΩ 100 Frequency, MHz 1,000 12.-(2) Malfunctional shock (latching) Tested sample: TQ2SA-12V, 6 pcs Tested sample: TQ2SA-L2-12V, 6 pcs. Z X X' Y 1000m/s 2 Deenergized condition Energized condition Z' Y Y' Z X X' Y 1000m/s 2 Reset condition Set condition X 1000m/s2 Z' 1000m/s 2 X 1000m/s2 Z' 1000m/s 2 1000m/s 2 Z 1000m/s 2 X' 1000m/s 2 Z 1000m/s 2 X' 1000m/s 2 Y' 0.8 0.6 12.-(1) Malfunctional shock (single side stable) Z' Y Y' 1.0 1000m/s 2 Y' All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 10 100 Frequency, MHz 1,000 TQ SMD Tested sample: TQ2SA-12V, 6 pcs. ON 0 ON –10 OFF OFF 10 Drop-out voltage 0 OFF –10 0 ON 10 Pick-up voltage 0 ON –10 ON Rate of change, % ON Pick-up voltage Rate of change, % Rate of change, % 10 Rate of change, % 13.-(3) Influence of adjacent mounting Tested sample: TQ2SA-12V, 6 pcs. Rate of change, % 13.-(2) Influence of adjacent mounting Tested sample: TQ2SA-12V, 5 pcs. Rate of change, % 13.-(1) Influence of adjacent mounting OFF 10 Drop-out voltage 0 OFF –10 OFF 0 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch 10 ON Pick-up voltage 0 ON –10 ON ON 10 OFF 0 Drop-out voltage OFF –10 OFF 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch 0 OFF 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch 14. Pulse dialing test 458 Ω + 0.08 µF 48 V DC 0.08 µF TQ-SMD 3 relay 2 – 458 Ω Wire spring relay Ratio against the rated voltage, %V Change of pick-up and drop-out voltage (mounting by IRS method) Change of contact resistance (mounting by IRS method) 100 100 90 90 80 Pick-up voltage 70 Max. 60 Min. 50 40 Drop-out voltage 30 Max. 20 Min. Contact resistance, mΩ Tested sample: TQ2SA-12V, 6 pcs. (35 mA 48 V DC wire spring relay load) Circuit 80 70 60 50 40 Max. 30 Min. 20 10 10 0 10 20 30 40 No. of operations, ×104 0 50 IRS 10 20 30 40 No. of operations, ×104 50 ;;; ; IRS NOTES 1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. 2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions (i) SA type (2) Dimensions of plastic reel mm inch ±0.8 21 .827 ±.031 mm inch Orientation (indicates PIN No.1)stripe 0.4 ±0.1 .016 ±.004 Stopper (gray) Relay polarity bar 4.0 ±0.1 .157 ±.004 (Z type) 1.75 ±0.1 1.5 +0.1 0 dia. ±.004 .059 +.004 dia. 0 2.0 ±0.1 .069 .079 ±.004 2.0 ±0.5 .079 ±.020 11.5 .453 14.6±0.1 .575±.004 Stopper (green) 6.3 ±0.2 .248 ±.008 2.0 .079 TQ-SMD relays +0.1 0 +.004 0 dia. 16.0±0.1 12.3 ±0.1 dia. .630±.004 .484 ±.004 24.0 ±0.3 .945 ±.012 Tape coming out direction mm inch 0.4 .016 Relay polarity bar (Z type) 1.5 +0.1 0 dia. .059 +.004 dia. 0 4.0 .157 ±0.1 ±.004 1.75 ±0.1 ±.004 2.0 ±0.1 .069 .079 ±.004 11.5 ±0.1 .453 ±.004 14.6±0.1 .575±.004 7.8 ±0.2 .307 ±.008 TQ-SMD relays Note) *SS type 2.0 +0.1 0 dia. 16.0 ±0.1 12.3 ±0.1 24.0 ±0.3 .079 +.004 dia. .630±.004 .484 ±.004 .945 ±.012 0 ±0.1 (10.1 Tape coming out direction .398 ±.004)* For Cautions for Use, see Relay Technical Information All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 330 ±2 dia. 12.992 ±.079 dia. 13 ±0.2 .512 ±.008 24.4+20 .961+.079 0 (ii) SL, SS type ±0.1 ±.004 100 ±1 dia. 3.937 ±.039 dia. ±0.1 ±.004 2.0±0.2 .079±.008