Transcript
TQ SMD
TESTING
LOW-PROFILE SURFACE-MOUNT RELAY
TQ SMD RELAYS
FEATURES 14 .551
9 .354 5.6 .220
mm inch
• Low-profile: 6 mm .236 inch (Tape height: max. 6.5 mm .256 inch) • Tape and reel package is available as standard packing style • Surge withstand between contacts and coil: 2,500 V • Breakdown voltage between contacts and coil: 1,500 V • Capacity: 2 A • High sensitivity: 2 Form C; 140 mW power consumption (Single side stable type)
SPECIFICATIONS Contact
Characteristics
Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Rating Max. switching voltage Max. switching current Min. switching capacity ❇1 Single side stable Nominal operating power
1 coil latching 2 coil latching
Expected life (min. operations)
Mechanical (at 180 cpm) 2 A 30 V DC resistive Electrical 1 A 30 V DC (at 20 cpm) resistive 0.5 A 125 V AC resistive
2 Form C 75 mΩ Gold-clad silver alloy 2 A 30 V DC, 0.5 A 125 V AC 60 W, 62.5 VA 220 V DC, 125 V AC 2A 10 µA 10 mV DC 140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 300 mW (48 V DC) 70 mW (1.5 to 12 V DC) 100 mW (24 V DC) 140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 108
Initial insulation resistance*1 Between open contacts Initial breakdown Between contact sets voltage Between contact and coil Between open contacts Initial surge (10×160 µs) voltage Between contacts and coil (2×10 µs) Temperature rise*2 (at 20°C) Operate time [Set time]*3 (at 20°C) Release time [Reset time]*4 (at 20°C) Functional*5 Shock resistance Destructive*6 Functional*7
105 Vibration resistance
Destructive
2×105 105
Note: ❇1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (SX relays are available for low level load switching [10 µA 1 mV DC – 10 mA 10 V DC])
Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight
Ambient temperature Humidity
Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 2 A. *3 Nominal voltage applied to the coil, excluding contact bounce time. *4 Nominal voltage applied to the coil, excluding contact bounce time without diode. *5 Half-wave pulse of sine wave: 6 ms; detection time: 10 µs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 µs *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Min. 1,000 MΩ (at 500 V DC) 1,000 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) 1,500 Vrms for 1 min. (Detection current: 10 mA) 1,500 V (FCC Part 68) 2,500 V (Telcordia) Max. 50°C Max. 4 ms (Approx. 2 ms) [Max. 4 ms (Approx. 2 ms)] Max. 4 ms (Approx. 1 ms) [Max. 4 ms (Approx. 2 ms)] Min. 750 m/s2 {75 G} Min. 1,000 m/s2 {100 G} 200 m/s2 {20G}, 10 to 55 Hz at double amplitude of 3.3 mm 294 m/s2 {30G}, 10 to 55 Hz at double amplitude of 5 mm –40°C to +85°C*3 –40°F to +185°F 5 to 85% R.H. Approx. 2 g .071 oz
TQ SMD ORDERING INFORMATION Ex. TQ Contact arrangement 2: 2 Form C
2
–
SA
Surface-mount availability SA: Standard surface-mount SA: terminal type SL : High connection reliability SA: surface-mount terminal type SS: Space saving surfaceSA: mount terminal type
L
–
3V
–
Z
Operating function
Coil voltage (DC)
Nil: Single side stable L: 1 coil latching L2: 2 coil latching
1.5, 3, 4.5, 5, 6, 9, 12, 24, 48* V
Packing style Nil: Tube packing Z: Tape and reel packing (picked from the 6/7/8/9/10-pin side)
*48 V coil type: Single side stable only Notes: 1. Tape and reel (picked from 1/2/3/4/5-pin side) is also available by request. Part No. suffix “-X” is needed when ordering. (ex.) TQ2SA-3V-X 2. Tape and reel packing symbol “-Z” or “-X” are not marked on the relay.
TYPES 1. Single side stable Nominal voltage, V DC
Pick-up voltage, V DC (max.)
Drop-out voltage, V DC (min.)
1.5 3 4.5 5 6 9 12 24 48
1.13 2.25 3.38 3.75 4.5 6.75 9 18 36
0.15 0.3 0.45 0.5 0.6 0.9 1.2 2.4 4.8
Nominal voltage, V DC
Set voltage, V DC (max.)
Reset voltage, V DC (max.)
1.5 3 4.5 5 6 9 12 24
1.13 2.25 3.38 3.75 4.5 6.75 9 18
1.13 2.25 3.38 3.75 4.5 6.75 9 18
Part No.
Nominal voltage, V DC
Set voltage, V DC (max.)
Reset voltage, V DC (max.)
TQ2S❍-L2-1.5 V TQ2S❍-L2-3 V TQ2S❍-L2-4.5 V TQ2S❍-L2-5 V TQ2S❍-L2-6 V TQ2S❍-L2-9 V TQ2S❍-L2-12 V TQ2S❍-L2-24 V
1.5 3 4.5 5 6 9 12 24
1.13 2.25 3.38 3.75 4.5 6.75 9 18
1.13 2.25 3.38 3.75 4.5 6.75 9 18
Part No. TQ2S❍-1.5 V TQ2S❍-3 V TQ2S❍-4.5 V TQ2S❍-5 V TQ2S❍-6 V TQ2S❍-9 V TQ2S❍-12 V TQ2S❍-24 V TQ2S❍-48 V
Nominal operating current, mA (±10%) 93.8 46.7 31 28.1 23.3 15.5 11.7 8.3 6.3
Coil resistance, Ω (±10%)
Nominal operating power, mW
Max. allowable voltage, V DC
16 64.3 145 178 257 579 1,028 2,880 7,680
140 140 140 140 140 140 140 200 300
2.2 4.5 6.7 7.5 9 13.5 18 36 57.6
Coil resistance, Ω (±10%)
Nominal operating power, mW
Max. allowable voltage, V DC
32 128.6 289.3 357 514 1,157 2,057 5,760
70 70 70 70 70 70 70 100
2.2 4.5 6.7 7.5 9 13.5 18 36
Coil resistance, Ω (±10%)
Nominal operating power, mW
Max. allowable voltage, V DC
16 64.3 145 178 257 579 1,028 2,880
140 140 140 140 140 140 140 200
2.2 4.5 6.7 7.5 9 13.5 18 36
2. 1 coil latching Part No. TQ2S❍-L-1.5 V TQ2S❍-L-3 V TQ2S❍-L-4.5 V TQ2S❍-L-5 V TQ2S❍-L-6 V TQ2S❍-L-9 V TQ2S❍-L-12 V TQ2S❍-L-24 V
Nominal operating current, mA (±10%) 46.9 23.3 15.6 14 11.7 7.8 5.8 4.2
3. 2 coil latching Nominal operating current, mA (±10%) 93.8 46.7 31 28.1 23.3 15.5 11.7 8.3
❍: For each surface-mounted terminal variation, input the following letter. SA type: A, SL type: L, SS type: S Notes: 1. Specified value of the pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse. 2. Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. Tape and reel: 500 pcs.; Case: 1,000 pcs. 3. In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
TQ SMD DIMENSIONS
mm inch
SA type 9 .354
14 .551
2.54 .100
0.5 .020
0.25 .010
4.9 .193
5.6 .220
Recommendable mounting pad (Top view) SA type 1 .039
7.62 .300 11.5±0.5 .453±.020
0.2 .008
Schematic (Top view) •Single side stable (Deenergized condition) −
10 9
8
7
6
1
3
4
5
2.54 .100
+
2 .079
2.94 .116
9.56 .376
SL type
2
Direction indication* *Orientation stripe located on top of relay.
9 .354
14 .551
0.25 .010
4.9 .193
Max. 7.5 .295 2.54 .100
0.3 .012
For glue-pad
•1-coil latching (Reset condition)
14 .551
+
SL type 7.62 .300 11.5±0.5 .453±.020
0.5 .020
1 .039
2.54 .100
9.56 .376
1
3
4
5
2
*Orientation stripe located on top of relay.
SS type
7.62 .300 9.3±0.5 ±.020
0.5 .020
6
•2-coil latching (Reset condition)
0.25 .010
4.9 .193
Max. 7.5 .295
7
Direction indication*
9 .354
14 .551
8
−
2.54 .100
2.94 .116
SS type
10 9
1 .039
General tolerance: ±0.3 ±.012
10 9
8
7
+
2.54 .100
−
+
1.84 .072
1
8.46 .333
6
−
2
3
4
5
Direction indication* *Orientation stripe located on top of relay.
Tolerance: ±0.1 ±.004
REFERENCE DATA 1. Maximum switching capacity
2. Life curve
3. Mechanical life (mounting by IRS method)
Ratio against the rated voltage, %V
Tested sample: TQ2SA-12V, 10 pcs.
No. of operations, × 104
Switching current, A
3.0 2.0
100
DC resistive load
1.0 AC resistive load
0.5 0.4 0.3
50 30
125V AC resistive load
30V DC resistive load
20 10
0.2
100 90 80 Pick-up voltage
70
Max.
60
Min.
50 40 Drop-out voltage
30
Max.
20 Min.
10 0
20 30
0
50 100 200 300 Contact voltage, V
0
1.0 2.0 Switching current, A
IRS 1
10 100 1,000 10,000 4 No. of operations, ×10
4.-(2) Electrical life (0.5 A 125 V AC resistive load)
Tested sample: TQ2SA-12V, 6 pcs. Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method)
Tested sample: TQ2SA-12V, 6 pcs Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method)
Change of contact resistance (mounting by IRS method) 100
90
90
80 Pick-up voltage
70 60
Max. Min.
50 40
Drop-out voltage
30 Max.
20
Min.
10 0
IRS 1
2
3 4 5 6 7 8 9 10 No. of operations, ×104
100
80 70 60 50
Max.
40 Min.
30 20
90 80 Pick-up voltage
70 60
Max. Min.
50 40
Drop-out voltage
30
Max.
20
Min.
10
10 0
Ratio against the rated voltage, %V
100
Contact resistance, mΩ
Ratio against the rated voltage, %V
4.-(1) Electrical life (2 A 30 V DC resistive load)
IRS 1
2
3 4 5 6 7 8 9 10 No. of operations, ×104
0
IRS 1
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
2
3 4 5 6 7 8 9 10 No. of operations, ×104
TQ SMD Change of contact resistance (mounting by IRS method)
5. Coil temperature rise
6. Operate/release time
Tested sample: TQ2SA-12V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F
Tested sample: TQ2SA-12V, 6 pcs.
100
70
70 60 50
Max.
40 Min.
30
60
5
2A
Coil voltage DC 12V type DC 48V type
0A
50 2A
40
0A
30 20
20
Operate and release time, ms
80
Temperature rise, °C
Contact resistance, mΩ
90
0
IRS 1
2
3
4
5
6
7
8
No. of operations, ×10
0
9 10
4 Max. Min.
3
2 Max. Min.
1
10
10
Operate time Release time
0
100 110 120 130 140 150 Coil applied voltage, %V
4
70
80
90 100 110 120 Coil applied voltage, %V
8. Distribution of set and reset voltage
9. Ambient temperature characteristics
Tested sample: TQ2SA-12V, 50 pcs.
Tested sample: TQ2SA-L-12V, 30 pcs.
Tested sample: TQ2SA-12V, 5 pcs.
Set voltage Reset voltage
; @ @ ; @ ; ;@;@;@;@;@;@;@
25
0
Quantity
–40 –20
15
0
; ; ;;;;; ;;;;;
10
20
;;;;; ;;;;;; ; ;
;@;@;@;@;@;@;@ ; @ @ ; @ ; Drop-out voltage
20
;;
30
Quantity
;;
30 Pick-up voltage
10
Rate of change, %
7. Distribution of pick-up and drop out voltage
40
20
Pick-up voltage x
Drop-out voltage 20 40 60 80 Ambient temperature, °C –20
5
0
10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V
–40
10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V
10. Distribution of contact resistance
11.-(1) High-frequency characteristics
11.-(2) High-frequency characteristics
Tested sample: TQ2SA-5V, 30 pcs. (30 × 4 contacts)
Isolation characteristics
Insertion loss characteristics
50 10 9 8 7 6
1 2 3 4 5
Isolation, dB
Terminal Nos. 2-3, 8-9
;
Quantity
(TOP VIEW)
;;;;;;;; ;;;;;; 30
20
10
0
20
Insertion loass, dB
;;;;;;;; ;;; Terminal Nos. 3-4, 7-8
;;;
40
– +
100
50
0.4 0.2 10
30 40 50 Contact resistance, mΩ
100 Frequency, MHz
1,000
12.-(2) Malfunctional shock (latching)
Tested sample: TQ2SA-12V, 6 pcs
Tested sample: TQ2SA-L2-12V, 6 pcs.
Z X
X' Y 1000m/s 2
Deenergized condition Energized condition
Z' Y Y'
Z X
X' Y 1000m/s 2
Reset condition Set condition
X 1000m/s2
Z' 1000m/s 2
X 1000m/s2
Z' 1000m/s 2
1000m/s 2 Z
1000m/s 2 X'
1000m/s 2 Z
1000m/s 2 X'
1000m/s 2 Y'
0.8 0.6
12.-(1) Malfunctional shock (single side stable)
Z' Y Y'
1.0
1000m/s 2 Y'
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
10
100 Frequency, MHz
1,000
TQ SMD Tested sample: TQ2SA-12V, 6 pcs.
ON
0 ON
–10
OFF OFF
10 Drop-out voltage 0
OFF
–10 0
ON
10 Pick-up voltage 0
ON –10 ON
Rate of change, %
ON Pick-up voltage
Rate of change, %
Rate of change, %
10
Rate of change, %
13.-(3) Influence of adjacent mounting
Tested sample: TQ2SA-12V, 6 pcs. Rate of change, %
13.-(2) Influence of adjacent mounting
Tested sample: TQ2SA-12V, 5 pcs. Rate of change, %
13.-(1) Influence of adjacent mounting
OFF
10 Drop-out voltage
0
OFF –10 OFF 0
1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
10
ON Pick-up voltage
0
ON
–10
ON ON
10
OFF
0
Drop-out voltage OFF
–10
OFF
1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
0
OFF 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
14. Pulse dialing test
458 Ω
+ 0.08 µF 48 V DC
0.08 µF
TQ-SMD 3 relay 2
–
458 Ω Wire spring relay
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage (mounting by IRS method)
Change of contact resistance (mounting by IRS method)
100
100
90
90
80 Pick-up voltage
70
Max.
60
Min.
50 40
Drop-out voltage
30
Max.
20
Min.
Contact resistance, mΩ
Tested sample: TQ2SA-12V, 6 pcs. (35 mA 48 V DC wire spring relay load) Circuit
80 70 60 50 40
Max.
30
Min.
20 10
10 0
10
20 30 40 No. of operations, ×104
0
50
IRS
10
20 30 40 No. of operations, ×104
50
;;; ;
IRS
NOTES
1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below.
2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions (i) SA type
(2) Dimensions of plastic reel
mm inch
±0.8
21 .827 ±.031
mm inch
Orientation (indicates PIN No.1)stripe
0.4 ±0.1 .016 ±.004
Stopper (gray)
Relay polarity bar 4.0 ±0.1 .157 ±.004 (Z type) 1.75 ±0.1 1.5 +0.1 0 dia. ±.004 .059 +.004 dia. 0 2.0 ±0.1 .069 .079 ±.004
2.0 ±0.5 .079 ±.020
11.5 .453 14.6±0.1 .575±.004
Stopper (green)
6.3 ±0.2 .248 ±.008
2.0 .079
TQ-SMD relays
+0.1 0 +.004 0
dia. 16.0±0.1 12.3 ±0.1 dia. .630±.004 .484 ±.004
24.0 ±0.3 .945 ±.012
Tape coming out direction
mm inch
0.4 .016
Relay polarity bar (Z type) 1.5 +0.1 0 dia. .059 +.004 dia. 0
4.0 .157
±0.1 ±.004
1.75 ±0.1 ±.004 2.0 ±0.1 .069 .079 ±.004
11.5 ±0.1 .453 ±.004 14.6±0.1 .575±.004
7.8 ±0.2 .307 ±.008
TQ-SMD relays
Note) *SS type
2.0 +0.1 0 dia. 16.0 ±0.1 12.3 ±0.1 24.0 ±0.3 .079 +.004 dia. .630±.004 .484 ±.004 .945 ±.012 0 ±0.1 (10.1 Tape coming out direction .398 ±.004)*
For Cautions for Use, see Relay Technical Information All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
330 ±2 dia. 12.992 ±.079 dia.
13 ±0.2 .512 ±.008
24.4+20 .961+.079 0
(ii) SL, SS type
±0.1 ±.004
100 ±1 dia. 3.937 ±.039 dia.
±0.1 ±.004
2.0±0.2 .079±.008