Preview only show first 10 pages with watermark. For full document please download

Tq Smd Relays Tq Smd Features Low-profile

   EMBED


Share

Transcript

TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY 14 .551 TQ SMD RELAYS FEATURES 9 .354 5.6 .220 mm inch • Low-profile: 6 mm .236 inch (Tape height: max. 6.5 mm .256 inch) • Tape and reel package is available as standard packing style • Surge withstand between contacts and coil: 2,500 V • Breakdown voltage between contacts and coil: 1,500 V • Capacity: 2 A • High sensitivity: 2 Form C; 140 mW power consumption (Single side stable type) SPECIFICATIONS Characteristics Contact Arrangement 2 Form C Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Rating Nominal operating power Nominal switching capacity (resistive load) 2 A 30 V DC, 0.5 A 125 V AC Max. switching power (resistive load) 60 W, 62.5 VA Max. switching voltage 220 V DC, 125 V AC Max. switching current 2A Min. switching capacity (Reference value)#1 10 μA 10 mV DC Single side stable 140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 300 mW (48 V DC) 1 coil latching 70 mW (1.5 to 12 V DC) 100 mW (24 V DC) Mechanical (at 180 cpm) Expected life (min. operations) 75 mΩ Au-clad AgNi type 2 coil latching 2 A 30 V DC resistive 1 A 30 V DC Electrical (at 20 cpm) resistive 0.5 A 125 V AC resistive Initial insulation resistance*1 140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 108 Initial breakdown voltage 1,000 Vrms for 1 min. (Detection current: 10 mA) Between contact sets 1,500 Vrms for 1 min. (Detection current: 10 mA) Between contact and coil 1,500 Vrms for 1 min. (Detection current: 10 mA) Between open contacts Initial surge (10×160 μs) voltage Between contacts and coil (2×10 μs) Temperature rise*2 (at 20°C) 105 Note: #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level]) 1,500 V (FCC Part 68) 2,500 V (Telcordia) Max. 50°C Operate time [Set time]* (at 20°C) Max. 4 ms [Max. 4 ms] Release time [Reset time]*4 (at 20°C) Max. 4 ms [Max. 4 ms] 3 Shock resistance Functional* Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight Min. 750 m/s2 {75 G} 5 Destructive* 6 Min. 1,000 m/s2 {100 G} Functional*7 200 m/s2 {20G}, 10 to 55 Hz at double amplitude of 3.3 mm Destructive 294 m/s2 {30G}, 10 to 55 Hz at double amplitude of 5 mm Ambient temperature –40°C to +85°C*3 –40°F to +185°F Vibration resistance 105 2×105 Min. 1,000 MΩ (at 500 V DC) Between open contacts Humidity 5 to 85% R.H. Approx. 2 g .071 oz Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 2 A. *3 Nominal voltage applied to the coil, excluding contact bounce time. 4 * Nominal voltage applied to the coil, excluding contact bounce time without diode. *5 Half-wave pulse of sine wave: 6 ms; detection time: 10 μs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 μs *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (p. 19, Relay Technical Information). ds_61020_0004_en_tqsmd: 101006J 1 TQ SMD ORDERING INFORMATION Ex. TQ Contact arrangement 2 Surface-mount availability 2: 2 Form C - SA SA: Standard surface-mount SA: terminal type SL: High connection reliability SA: surface-mount terminal type SS: Space saving surfaceSA: mount terminal type L - 3V - Z Operating function Coil voltage (DC) Nil: Single side stable L: 1 coil latching L2: 2 coil latching 1.5, 3, 4.5, 5, 6, 9, 12, 24, 48* V Packing style Nil: Tube packing Z: Tape and reel packing (picked from the 6/7/8/9/10-pin side) *48 V coil type: Single side stable only Notes: 1. Tape and reel (picked from 1/2/3/4/5-pin side) is also available by request. Part No. suffix “-X” is needed when ordering. (ex.) TQ2SA-3V-X 2. Tape and reel packing symbol “-Z” or “-X” are not marked on the relay. TYPES 1. Single side stable Nominal voltage, V DC Pick-up voltage, V DC (max.) Drop-out voltage, V DC (min.) Nominal operating current, mA (±10%) 1.5 1.13 0.15 3 2.25 0.3 4.5 3.38 TQ2SP-5 V 5 TQ2SP-6 V 6 TQ2SP-9 V 9 TQ2SP-12 V TQ2SP-24 V TQ2SP-48 V Coil resistance, Ω (±10%) Nominal operating power, mW Max. allowable voltage, V DC 93.8 16 140 2.2 46.7 64.3 140 4.5 0.45 31 145 140 6.7 3.75 0.5 28.1 178 140 7.5 4.5 0.6 23.3 257 140 9 6.75 0.9 15.5 579 140 13.5 12 9 1.2 11.7 1,028 140 18 24 18 2.4 8.3 2,880 200 36 48 36 4.8 6.3 7,680 300 57.6 Part No. Nominal voltage, V DC Set voltage, V DC (max.) Reset voltage, V DC (max.) Nominal operating current, mA (±10%) Coil resistance, Ω (±10%) Nominal operating power, mW Max. allowable voltage, V DC TQ2SP-L-1.5 V 1.5 1.13 1.13 46.9 32 70 2.2 3 2.25 2.25 23.3 128.6 70 4.5 Part No. TQ2SP-1.5 V TQ2SP-3 V TQ2SP-4.5 V 2. 1 coil latching TQ2SP-L-3 V TQ2SP-L-4.5 V 4.5 3.38 3.38 15.6 289.3 70 6.7 TQ2SP-L-5 V 5 3.75 3.75 14 357 70 7.5 TQ2SP-L-6 V 6 4.5 4.5 11.7 514 70 9 TQ2SP-L-9 V 9 6.75 6.75 7.8 1,157 70 13.5 TQ2SP-L-12 V 12 9 9 5.8 2,057 70 18 TQ2SP-L-24 V 24 18 18 4.2 5,760 100 36 Part No. Nominal voltage, V DC Set voltage, V DC (max.) Reset voltage, V DC (max.) Nominal operating current, mA (±10%) Coil resistance, Ω (±10%) Nominal operating power, mW Max. allowable voltage, V DC TQ2SP-L2-1.5 V 1.5 1.13 1.13 93.8 16 140 2.2 3 2.25 2.25 46.7 64.3 140 4.5 3. 2 coil latching TQ2SP-L2-3 V TQ2SP-L2-4.5 V 4.5 3.38 3.38 31 145 140 6.7 TQ2SP-L2-5 V 5 3.75 3.75 28.1 178 140 7.5 TQ2SP-L2-6 V 6 4.5 4.5 23.3 257 140 9 TQ2SP-L2-9 V 9 6.75 6.75 15.5 579 140 13.5 TQ2SP-L2-12 V 12 9 9 11.7 1,028 140 18 TQ2SP-L2-24 V 24 18 18 8.3 2,880 200 36 P: For each surface-mounted terminal variation, input the following letter. SA type: A, SL type: L, SS type: S Notes: 1. Specified value of the pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse. 2. Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. Tape and reel: 500 pcs.; Case: 1,000 pcs. 3. In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay. 2 ds_61020_0004_en_tqsmd: 101006J TQ SMD DIMENSIONS mm inch SA type 9 .354 14 .551 2.54 .100 0.5 .020 0.25 .010 4.9 .193 5.6 .220 7.62 .300 11.50.5 .453.020 0.2 .008 Recommendable mounting pad (Top view) SA type Schematic (Top view) •Single side stable (Deenergized condition) − 1 .039 10 9 8 7 6 1 3 4 5 2.54 .100 2 .079 2.94 .116 + 9.56 .376 2 Direction indication* SL type *Orientation stripe located on top of relay. 9 .354 14 .551 0.25 .010 4.9 .193 Max. 7.5 .295 2.54 .100 0.3 .012 For glue-pad •1-coil latching (Reset condition) 14 .551 + SL type 7.62 .300 11.50.5 .453.020 0.5 .020 1 .039 SS type 2.54 .100 − 2.54 .100 9.56 .376 9 .354 6 1 3 4 5 2 *Orientation stripe located on top of relay. SS type 7.62 .300 9.30.5 .020 0.5 .020 7 •2-coil latching (Reset condition) 0.25 .010 4.9 .193 Max. 7.5 .295 8 Direction indication* 2.94 .116 14 .551 10 9 1 .039 10 9 8 7 + 2.54 .100 − + General tolerance: ±0.3 ±.012 1.84 .072 1 8.46 .333 6 − 2 3 4 5 Direction indication* *Orientation stripe located on top of relay. Tolerance: ±0.1 ±.004 REFERENCE DATA 1. Maximum switching capacity 2. Life curve 3. Mechanical life (mounting by IRS method) Ratio against the rated voltage, %V Tested sample: TQ2SA-12V, 10 pcs. No. of operations, × 104 Switching current, A 3.0 2.0 100 DC resistive load 1.0 AC resistive load 0.5 0.4 0.3 50 125V AC resistive load 30 30V DC resistive load 20 10 0.2 100 90 80 Pick-up voltage 70 60 Min. 50 40 Drop-out voltage 30 20 20 30 0 50 100 200 300 Contact voltage, V 0 1.0 2.0 Switching current, A Max. Min. 10 0 Max. IRS 1 10 100 1,000 10,000 4 No. of operations, ×10 4.-(2) Electrical life (0.5 A 125 V AC resistive load) Tested sample: TQ2SA-12V, 6 pcs. Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method) Tested sample: TQ2SA-12V, 6 pcs Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method) Change of contact resistance (mounting by IRS method) 100 90 90 80 Pick-up voltage 70 60 Max. Min. 50 40 Drop-out voltage 30 Max. 20 Min. 10 0 IRS 1 2 3 4 5 6 7 8 9 10 No. of operations, ×104 ds_61020_0004_en_tqsmd: 101006J 100 80 70 60 50 Max. 40 Min. 30 20 10 0 IRS 1 2 3 4 5 6 7 8 9 10 No. of operations, ×104 Ratio against the rated voltage, %V 100 Contact resistance, mΩ Ratio against the rated voltage, %V 4.-(1) Electrical life (2 A 30 V DC resistive load) 90 80 Pick-up voltage 70 60 Max. Min. 50 40 Drop-out voltage 30 Max. 20 Min. 10 0 IRS 1 2 3 4 5 6 7 8 9 10 4 No. of operations, ×10 3 TQ SMD Change of contact resistance (mounting by IRS method) 5. Coil temperature rise 6. Operate/release time Tested sample: TQ2SA-12V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F Tested sample: TQ2SA-12V, 6 pcs. 60 Temperature rise, C 80 70 60 50 Max. 40 0A 50 2A 40 0A 30 Min. 30 2A Coil voltage DC 12V type DC 48V type 20 20 Operate and release time, ms 90 Contact resistance, m 5 70 100 0 IRS 1 2 3 4 5 6 7 8 0 9 10 No. of operations, ×10 4 4 Max. Min. 3 2 Max. Min. 1 10 10 Operate time Release time 0 100 110 120 130 140 150 Coil applied voltage, %V 70 90 100 110 120 Coil applied voltage, %V 80 8. Distribution of set and reset voltage 9. Ambient temperature characteristics Tested sample: TQ2SA-12V, 50 pcs. Tested sample: TQ2SA-L-12V, 30 pcs. Tested sample: TQ2SA-12V, 5 pcs. 30 Pick-up voltage 30 25 Quantity Drop-out voltage Quantity Set voltage Reset voltage 20 20 -40 -20 15 0 Rate of change, % 7. Distribution of pick-up and drop out voltage 10 10 40 20 Pick-up voltage x Drop-out voltage 20 40 60 80 Ambient temperature, °C -20 5 -40 0 0 10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V 10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V 10. Distribution of contact resistance 11.-(1) High-frequency characteristics 11.-(2) High-frequency characteristics Tested sample: TQ2SA-5V, 30 pcs. (30 × 4 contacts) Isolation characteristics Insertion loss characteristics 50 10 9 8 7 6 Ð + Terminal Nos. 3-4, 7-8 1 2 3 4 5 Terminal Nos. 2-3, 8-9 30 20 Insertion loass, dB (TOP VIEW) Isolation, dB Quantity 40 100 50 0.4 0.2 20 30 40 50 Contact resistance, m 10 100 Frequency, MHz 1,000 12.-(1) Malfunctional shock (single side stable) 12.-(2) Malfunctional shock (latching) Tested sample: TQ2SA-12V, 6 pcs Tested sample: TQ2SA-L2-12V, 6 pcs. Z' Y Y' Z X X' Y 1000m/s 2 Deenergized condition Energized condition Z' Y Y' Z X X' Y 1000m/s 2 10 100 Frequency, MHz 1,000 Reset condition Set condition X 1000m/s2 Z' 1000m/s 2 X 1000m/s2 Z' 1000m/s 2 1000m/s 2 Z 1000m/s 2 X' 1000m/s 2 Z 1000m/s 2 X' 1000m/s 2 Y' 4 0.8 0.6 10 0 1.0 1000m/s 2 Y' ds_61020_0004_en_tqsmd: 101006J TQ SMD Tested sample: TQ2SA-12V, 6 pcs. ON 0 ON Ð10 Drop-out voltage 0 OFF Ð10 0 10 Pick-up voltage 0 ON Ð10 OFF OFF 10 ON ON Rate of change, % ON Pick-up voltage Rate of change, % Rate of change, % 10 Rate of change, % 13.-(3) Influence of adjacent mounting Tested sample: TQ2SA-12V, 6 pcs. Rate of change, % 13.-(2) Influence of adjacent mounting Tested sample: TQ2SA-12V, 5 pcs. Rate of change, % 13.-(1) Influence of adjacent mounting OFF 10 Drop-out voltage 0 OFF Ð10 OFF 0 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch 10 ON Pick-up voltage 0 ON Ð10 ON ON 10 OFF 0 Drop-out voltage OFF Ð10 OFF 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch 0 OFF 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch 14. Pulse dialing test Change of pick-up and drop-out voltage (mounting by IRS method) 0.08 F 48 V DC 0.08 F TQ-SMD 3 relay 2 Ð 458 Wire spring relay 100 90 90 80 Pick-up voltage 70 Max. 60 Min. 50 40 Drop-out voltage 30 Max. Min. 20 80 70 60 50 40 Max. 30 Min. 20 10 10 0 Contact resistance, mΩ 458 + Change of contact resistance (mounting by IRS method) 100 Ratio against the rated voltage, %V Tested sample: TQ2SA-12V, 6 pcs. (35 mA 48 V DC wire spring relay load) Circuit IRS 10 20 30 40 No. of operations, ×104 0 50 IRS 10 20 30 40 No. of operations, ×104 50 NOTES 1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. 2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions (i) SA type mm inch Orientation (indicates PIN No.1)stripe 0.4 0.1 .016 .004 Stopper (gray) Stopper (green) Relay polarity bar 4.0 0.1 .157 .004 (Z type) 1.75 0.1 1.5 +0.1 0 dia. .004 +.004 .059 0 dia. 2.0 0.1 .069 .079 .004 (2) Dimensions of plastic reel mm inch 21 0.8 .827 .031 2.0 0.5 .079 .020 100 1 dia. 3.937 .039 dia. 0.1 .004 11.5 .453 14.60.1 .575.004 2.0 .079 6.3 0.2 .248 .008 TQ-SMD relays +0.1 0 +.004 0 dia. 16.00.1 12.3 0.1 dia. .630.004 .484 .004 24.0 0.3 .945 .012 Tape coming out direction 330 2 dia. 12.992 .079 dia. 13 0.2 .512 .008 24.4+20 .961+.079 0 (ii) SL, SS type 2.00.2 .079.008 mm inch 0.4 0.1 .016 .004 Relay polarity bar (Z type) 1.5 +0.1 0 dia. .059 +.004 dia. 0 7.8 0.2 .307 .008 TQ-SMD relays Note) *SS type 4.0 0.1 .157 .004 1.75 0.1 .004 2.0 0.1 .069 .079 .004 11.5 0.1 .453 .004 14.60.1 .575.004 2.0 +0.1 0 dia. 16.0 0.1 12.3 0.1 24.0 0.3 .079 +.004 dia. .630.004 .484 .004 .945 .012 0 0.1 (10.1 Tape coming out direction .398 .004 )* For Cautions for Use, see Relay Technical Information. ds_61020_0004_en_tqsmd: 101006J 5