TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY
14 .551
TQ SMD RELAYS
FEATURES
9 .354 5.6 .220
mm inch
• Low-profile: 6 mm .236 inch (Tape height: max. 6.5 mm .256 inch) • Tape and reel package is available as standard packing style • Surge withstand between contacts and coil: 2,500 V • Breakdown voltage between contacts and coil: 1,500 V • Capacity: 2 A • High sensitivity: 2 Form C; 140 mW power consumption (Single side stable type)
SPECIFICATIONS Characteristics
Contact Arrangement
2 Form C
Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material
Rating
Nominal operating power
Nominal switching capacity (resistive load)
2 A 30 V DC, 0.5 A 125 V AC
Max. switching power (resistive load)
60 W, 62.5 VA
Max. switching voltage
220 V DC, 125 V AC
Max. switching current
2A
Min. switching capacity (Reference value)#1
10 μA 10 mV DC
Single side stable
140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 300 mW (48 V DC)
1 coil latching
70 mW (1.5 to 12 V DC) 100 mW (24 V DC)
Mechanical (at 180 cpm) Expected life (min. operations)
75 mΩ Au-clad AgNi type
2 coil latching
2 A 30 V DC resistive 1 A 30 V DC Electrical (at 20 cpm) resistive 0.5 A 125 V AC resistive
Initial insulation resistance*1
140 mW (1.5 to 12 V DC) 200 mW (24 V DC) 108
Initial breakdown voltage
1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact sets
1,500 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil
1,500 Vrms for 1 min. (Detection current: 10 mA)
Between open contacts Initial surge (10×160 μs) voltage Between contacts and coil (2×10 μs) Temperature rise*2 (at 20°C)
105
Note: #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level])
1,500 V (FCC Part 68) 2,500 V (Telcordia) Max. 50°C
Operate time [Set time]* (at 20°C)
Max. 4 ms [Max. 4 ms]
Release time [Reset time]*4 (at 20°C)
Max. 4 ms [Max. 4 ms]
3
Shock resistance
Functional*
Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight
Min. 750 m/s2 {75 G}
5
Destructive*
6
Min. 1,000 m/s2 {100 G}
Functional*7
200 m/s2 {20G}, 10 to 55 Hz at double amplitude of 3.3 mm
Destructive
294 m/s2 {30G}, 10 to 55 Hz at double amplitude of 5 mm
Ambient temperature
–40°C to +85°C*3 –40°F to +185°F
Vibration resistance
105 2×105
Min. 1,000 MΩ (at 500 V DC)
Between open contacts
Humidity
5 to 85% R.H. Approx. 2 g .071 oz
Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as “Initial breakdown voltage” section. *2 By resistive method, nominal voltage applied to the coil; contact carrying current: 2 A. *3 Nominal voltage applied to the coil, excluding contact bounce time. 4 * Nominal voltage applied to the coil, excluding contact bounce time without diode. *5 Half-wave pulse of sine wave: 6 ms; detection time: 10 μs *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 μs *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (p. 19, Relay Technical Information).
ds_61020_0004_en_tqsmd: 101006J
1
TQ SMD ORDERING INFORMATION Ex. TQ Contact arrangement
2
Surface-mount availability
2: 2 Form C
-
SA
SA: Standard surface-mount SA: terminal type SL: High connection reliability SA: surface-mount terminal type SS: Space saving surfaceSA: mount terminal type
L
-
3V
-
Z
Operating function
Coil voltage (DC)
Nil: Single side stable L: 1 coil latching L2: 2 coil latching
1.5, 3, 4.5, 5, 6, 9, 12, 24, 48* V
Packing style Nil: Tube packing Z: Tape and reel packing (picked from the 6/7/8/9/10-pin side)
*48 V coil type: Single side stable only Notes: 1. Tape and reel (picked from 1/2/3/4/5-pin side) is also available by request. Part No. suffix “-X” is needed when ordering. (ex.) TQ2SA-3V-X 2. Tape and reel packing symbol “-Z” or “-X” are not marked on the relay.
TYPES 1. Single side stable Nominal voltage, V DC
Pick-up voltage, V DC (max.)
Drop-out voltage, V DC (min.)
Nominal operating current, mA (±10%)
1.5
1.13
0.15
3
2.25
0.3
4.5
3.38
TQ2SP-5 V
5
TQ2SP-6 V
6
TQ2SP-9 V
9
TQ2SP-12 V TQ2SP-24 V TQ2SP-48 V
Coil resistance, Ω (±10%)
Nominal operating power, mW
Max. allowable voltage, V DC
93.8
16
140
2.2
46.7
64.3
140
4.5
0.45
31
145
140
6.7
3.75
0.5
28.1
178
140
7.5
4.5
0.6
23.3
257
140
9
6.75
0.9
15.5
579
140
13.5
12
9
1.2
11.7
1,028
140
18
24
18
2.4
8.3
2,880
200
36
48
36
4.8
6.3
7,680
300
57.6
Part No.
Nominal voltage, V DC
Set voltage, V DC (max.)
Reset voltage, V DC (max.)
Nominal operating current, mA (±10%)
Coil resistance, Ω (±10%)
Nominal operating power, mW
Max. allowable voltage, V DC
TQ2SP-L-1.5 V
1.5
1.13
1.13
46.9
32
70
2.2
3
2.25
2.25
23.3
128.6
70
4.5
Part No. TQ2SP-1.5 V TQ2SP-3 V TQ2SP-4.5 V
2. 1 coil latching
TQ2SP-L-3 V TQ2SP-L-4.5 V
4.5
3.38
3.38
15.6
289.3
70
6.7
TQ2SP-L-5 V
5
3.75
3.75
14
357
70
7.5
TQ2SP-L-6 V
6
4.5
4.5
11.7
514
70
9
TQ2SP-L-9 V
9
6.75
6.75
7.8
1,157
70
13.5
TQ2SP-L-12 V
12
9
9
5.8
2,057
70
18
TQ2SP-L-24 V
24
18
18
4.2
5,760
100
36
Part No.
Nominal voltage, V DC
Set voltage, V DC (max.)
Reset voltage, V DC (max.)
Nominal operating current, mA (±10%)
Coil resistance, Ω (±10%)
Nominal operating power, mW
Max. allowable voltage, V DC
TQ2SP-L2-1.5 V
1.5
1.13
1.13
93.8
16
140
2.2
3
2.25
2.25
46.7
64.3
140
4.5
3. 2 coil latching
TQ2SP-L2-3 V TQ2SP-L2-4.5 V
4.5
3.38
3.38
31
145
140
6.7
TQ2SP-L2-5 V
5
3.75
3.75
28.1
178
140
7.5
TQ2SP-L2-6 V
6
4.5
4.5
23.3
257
140
9
TQ2SP-L2-9 V
9
6.75
6.75
15.5
579
140
13.5
TQ2SP-L2-12 V
12
9
9
11.7
1,028
140
18
TQ2SP-L2-24 V
24
18
18
8.3
2,880
200
36
P: For each surface-mounted terminal variation, input the following letter. SA type: A, SL type: L, SS type: S Notes: 1. Specified value of the pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse. 2. Standard packing: Tube: 50 pcs.; Case: 1,000 pcs. Tape and reel: 500 pcs.; Case: 1,000 pcs. 3. In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
2
ds_61020_0004_en_tqsmd: 101006J
TQ SMD DIMENSIONS
mm inch
SA type 9 .354
14 .551
2.54 .100
0.5 .020
0.25 .010
4.9 .193
5.6 .220
7.62 .300 11.50.5 .453.020
0.2 .008
Recommendable mounting pad (Top view) SA type
Schematic (Top view) •Single side stable (Deenergized condition) −
1 .039
10 9
8
7
6
1
3
4
5
2.54 .100 2 .079
2.94 .116
+
9.56 .376
2
Direction indication*
SL type
*Orientation stripe located on top of relay. 9 .354
14 .551
0.25 .010
4.9 .193
Max. 7.5 .295 2.54 .100
0.3 .012
For glue-pad
•1-coil latching (Reset condition)
14 .551
+
SL type 7.62 .300 11.50.5 .453.020
0.5 .020
1 .039
SS type
2.54 .100
−
2.54 .100
9.56 .376
9 .354
6
1
3
4
5
2
*Orientation stripe located on top of relay.
SS type
7.62 .300 9.30.5 .020
0.5 .020
7
•2-coil latching (Reset condition)
0.25 .010
4.9 .193
Max. 7.5 .295
8
Direction indication*
2.94 .116 14 .551
10 9
1 .039
10 9
8
7
+
2.54 .100
−
+
General tolerance: ±0.3 ±.012
1.84 .072
1
8.46 .333
6
−
2
3
4
5
Direction indication* *Orientation stripe located on top of relay.
Tolerance: ±0.1 ±.004
REFERENCE DATA 1. Maximum switching capacity
2. Life curve
3. Mechanical life (mounting by IRS method)
Ratio against the rated voltage, %V
Tested sample: TQ2SA-12V, 10 pcs.
No. of operations, × 104
Switching current, A
3.0 2.0
100
DC resistive load
1.0 AC resistive load
0.5 0.4 0.3
50 125V AC resistive load
30
30V DC resistive load
20 10
0.2
100 90 80 Pick-up voltage
70 60
Min.
50 40 Drop-out voltage
30 20
20 30
0
50 100 200 300 Contact voltage, V
0
1.0 2.0 Switching current, A
Max. Min.
10 0
Max.
IRS 1
10 100 1,000 10,000 4 No. of operations, ×10
4.-(2) Electrical life (0.5 A 125 V AC resistive load)
Tested sample: TQ2SA-12V, 6 pcs. Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method)
Tested sample: TQ2SA-12V, 6 pcs Operating frequency: 20 cpm Change of pick-up and drop-out voltage (mounting by IRS method)
Change of contact resistance (mounting by IRS method) 100
90
90
80 Pick-up voltage
70 60
Max. Min.
50 40
Drop-out voltage
30
Max.
20
Min.
10 0
IRS 1
2
3 4 5 6 7 8 9 10 No. of operations, ×104
ds_61020_0004_en_tqsmd: 101006J
100
80 70 60 50
Max.
40 Min.
30 20 10 0
IRS 1
2
3 4 5 6 7 8 9 10 No. of operations, ×104
Ratio against the rated voltage, %V
100
Contact resistance, mΩ
Ratio against the rated voltage, %V
4.-(1) Electrical life (2 A 30 V DC resistive load)
90 80 Pick-up voltage
70 60
Max. Min.
50 40
Drop-out voltage
30
Max.
20
Min.
10 0
IRS 1
2
3 4 5 6 7 8 9 10 4 No. of operations, ×10
3
TQ SMD Change of contact resistance (mounting by IRS method)
5. Coil temperature rise
6. Operate/release time
Tested sample: TQ2SA-12V, 6 pcs. Point measured: Inside the coil Ambient temperature: 25°C 77°F
Tested sample: TQ2SA-12V, 6 pcs.
60
Temperature rise, C
80 70 60 50
Max.
40
0A
50 2A
40
0A
30
Min.
30
2A
Coil voltage DC 12V type DC 48V type
20
20
Operate and release time, ms
90 Contact resistance, m
5
70
100
0
IRS 1
2
3
4
5
6
7
8
0
9 10
No. of operations, ×10
4
4 Max. Min.
3
2 Max. Min.
1
10
10
Operate time Release time
0
100 110 120 130 140 150 Coil applied voltage, %V
70
90 100 110 120 Coil applied voltage, %V
80
8. Distribution of set and reset voltage
9. Ambient temperature characteristics
Tested sample: TQ2SA-12V, 50 pcs.
Tested sample: TQ2SA-L-12V, 30 pcs.
Tested sample: TQ2SA-12V, 5 pcs.
30 Pick-up voltage
30
25 Quantity
Drop-out voltage
Quantity
Set voltage Reset voltage
20
20 -40 -20
15
0
Rate of change, %
7. Distribution of pick-up and drop out voltage
10 10
40
20
Pick-up voltage x
Drop-out voltage 20 40 60 80 Ambient temperature, °C -20
5 -40 0
0
10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V
10 20 30 40 50 60 70 80 90 100 Ratio against the rated voltage, %V
10. Distribution of contact resistance
11.-(1) High-frequency characteristics
11.-(2) High-frequency characteristics
Tested sample: TQ2SA-5V, 30 pcs. (30 × 4 contacts)
Isolation characteristics
Insertion loss characteristics
50 10 9 8 7 6
Ð +
Terminal Nos. 3-4, 7-8
1 2 3 4 5
Terminal Nos. 2-3, 8-9
30
20
Insertion loass, dB
(TOP VIEW)
Isolation, dB
Quantity
40
100
50
0.4 0.2 20
30 40 50 Contact resistance, m
10
100 Frequency, MHz
1,000
12.-(1) Malfunctional shock (single side stable)
12.-(2) Malfunctional shock (latching)
Tested sample: TQ2SA-12V, 6 pcs
Tested sample: TQ2SA-L2-12V, 6 pcs.
Z' Y Y'
Z X
X' Y 1000m/s 2
Deenergized condition Energized condition
Z' Y Y'
Z X
X' Y 1000m/s 2
10
100 Frequency, MHz
1,000
Reset condition Set condition
X 1000m/s2
Z' 1000m/s 2
X 1000m/s2
Z' 1000m/s 2
1000m/s 2 Z
1000m/s 2 X'
1000m/s 2 Z
1000m/s 2 X'
1000m/s 2 Y'
4
0.8 0.6
10
0
1.0
1000m/s 2 Y'
ds_61020_0004_en_tqsmd: 101006J
TQ SMD Tested sample: TQ2SA-12V, 6 pcs.
ON
0 ON
Ð10
Drop-out voltage 0 OFF
Ð10 0
10 Pick-up voltage 0
ON
Ð10
OFF OFF
10
ON
ON
Rate of change, %
ON Pick-up voltage
Rate of change, %
Rate of change, %
10
Rate of change, %
13.-(3) Influence of adjacent mounting
Tested sample: TQ2SA-12V, 6 pcs. Rate of change, %
13.-(2) Influence of adjacent mounting
Tested sample: TQ2SA-12V, 5 pcs. Rate of change, %
13.-(1) Influence of adjacent mounting
OFF
10 Drop-out voltage
0
OFF
Ð10 OFF 0
1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
10
ON Pick-up voltage
0
ON
Ð10
ON ON
10
OFF
0
Drop-out voltage OFF
Ð10
OFF
1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
0
OFF 1 2 3 4 5 6 .039 .079 .118 .157 .197 .236 Inter-relay distance , mm inch
14. Pulse dialing test Change of pick-up and drop-out voltage (mounting by IRS method)
0.08 F 48 V DC
0.08 F
TQ-SMD 3 relay 2
Ð 458 Wire spring relay
100
90
90
80 Pick-up voltage
70
Max.
60
Min.
50 40
Drop-out voltage
30
Max. Min.
20
80 70 60 50 40
Max.
30
Min.
20 10
10 0
Contact resistance, mΩ
458
+
Change of contact resistance (mounting by IRS method)
100
Ratio against the rated voltage, %V
Tested sample: TQ2SA-12V, 6 pcs. (35 mA 48 V DC wire spring relay load) Circuit
IRS
10
20 30 40 No. of operations, ×104
0
50
IRS
10
20 30 40 No. of operations, ×104
50
NOTES 1. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below.
2) Tape and reel packing (surface-mount terminal type) (1) Tape dimensions (i) SA type mm inch
Orientation (indicates PIN No.1)stripe 0.4 0.1 .016 .004
Stopper (gray)
Stopper (green)
Relay polarity bar 4.0 0.1 .157 .004 (Z type) 1.75 0.1 1.5 +0.1 0 dia. .004 +.004 .059 0 dia. 2.0 0.1 .069 .079 .004
(2) Dimensions of plastic reel mm inch 21 0.8 .827 .031
2.0 0.5 .079 .020 100 1 dia. 3.937 .039 dia.
0.1 .004
11.5 .453 14.60.1 .575.004
2.0 .079
6.3 0.2 .248 .008
TQ-SMD relays
+0.1 0 +.004 0
dia. 16.00.1 12.3 0.1 dia. .630.004 .484 .004
24.0 0.3 .945 .012
Tape coming out direction
330 2 dia. 12.992 .079 dia. 13 0.2 .512 .008 24.4+20 .961+.079 0
(ii) SL, SS type
2.00.2 .079.008
mm inch
0.4 0.1 .016 .004
Relay polarity bar (Z type) 1.5 +0.1 0 dia. .059 +.004 dia. 0
7.8 0.2 .307 .008
TQ-SMD relays
Note) *SS type
4.0 0.1 .157 .004
1.75 0.1 .004 2.0 0.1 .069 .079 .004 11.5 0.1 .453 .004 14.60.1 .575.004
2.0 +0.1 0 dia. 16.0 0.1 12.3 0.1 24.0 0.3 .079 +.004 dia. .630.004 .484 .004 .945 .012 0 0.1 (10.1 Tape coming out direction .398 .004 )*
For Cautions for Use, see Relay Technical Information.
ds_61020_0004_en_tqsmd: 101006J
5