Transcript
TECHNICAL REFERENCE
Application Server ‘‘High Performance’’ 1U Hardware Manual
2013-10-19 / TR-APS1-2500A
Author : HWINT e-mail :
[email protected]
1
TECHNICAL REFERENCE
Table of Contents Introduction............................................................................................................................................................................................................................ 3 Chassis Dimensions.............................................................................................................................................................................................................. 4 Power Supply......................................................................................................................................................................................................................... 5 Hardware & Operating System.............................................................................................................................................................................................. 5 Storage Configuration............................................................................................................................................................................................................ 5 I/Os
.................................................................................................................................................................................................................................. 6
Author : HWINT e-mail :
[email protected]
2
TECHNICAL REFERENCE
Introduction This technical document provides an overview on the different hardware configurations, a brief description of the connectors.
EVS product ID : APS1-2D : Application Server “High Performance”
front view
rear view (with no optional board)
Note Only one option can be selected at a time.
Author : HWINT e-mail :
[email protected]
3
TECHNICAL REFERENCE
Chassis Dimensions a b
f
d c
g
mm
in
a
482.60
19.00
b
465.00
18.31
c
5.95
0.23
d
31.75
1.25
e
517.50
20.37
f
43.65
1.72
g
444.40
17.50
h
460.50
18.13
i
447.00
17.60
j
54.00
2.13
h e
j i
Author : HWINT e-mail :
[email protected]
4
TECHNICAL REFERENCE
Power Supply The power supply(a) is redundant(b) and hot-swappable(c). [1] Housing model: PSU-1-LH-01 [2] Module model: PSU-1-LM-01 (d) Specifications : AC input : 100-240V, 47-63Hz, 6-3A DC output : 400W (MAX)
1 2
2
(a): ROHS compliant (b): If one module fails, the remaining module will provide enough power to the server. (c): One module can be changed when the server is running, as long as the other module is still powered. (d): Two modules per housing Note In case of failure, please order a new PSU directly from EVS.
Hardware & Operating System Motherboard : Dual CPU CPU : 2 Hexa Core CPU at 2.2GHz with HyperThreading RAM : 8GB DDR3 ECC 1600 HDD : 2x 250GB (SATA, 2.5”) for operating system - RAID 1 OS : Windows Server 2008 R2 Standard Edition (64 bits)
Storage Configuration The OS will be installed on a RAID1 built as below. Physical Drives
RAID type
Drive Partitions Basic disk
250 GB - #1 (SATA) RAID 1 250 GB - #2 (SATA)
Author : HWINT e-mail :
[email protected]
Always Write Back No Read Ahead
Direct IO Stripe Size : 64 KB
System [C:] 80 GB NTFS, 4KB
Restore [R:] 80 GB
not allocated 90 GB
NTFS, 4KB
5
TECHNICAL REFERENCE
I/Os 1x PS/2 keyboard connector 1x PS/2 mouse connector 1x VGA connector (D-sub DE-15F) 1x COM port (D-sub DE-9M) 3x USB 2.0 ports 1x IMPI port (RJ45) 2x Gigabit Ethernet ports (RJ45)
Front Power LED
HDD LED
USB 2.0
Power switch
Rear PS/2 mouse
PS/2 keyboard
Author : HWINT e-mail :
[email protected]
IPMI
COM
USB 2.0
VGA
Gigabit LAN 1&2 (JumboFrame Capable)
6