Preview only show first 10 pages with watermark. For full document please download

Trenton Hall Annex - Allied Health - Optometry (2 Labs) Trenton Hall

   EMBED


Share

Transcript

Trenton Hall Annex ‐ Allied Health ‐ Plebotomy Lab Trenton Hall Annex ‐ Allied Health ‐ Optometry  (2 labs) Qty Component 1 Media connector  plate  Manufacturer Extron  1 Connector plate with  Extron  HDMI, VGA, 3.5mm  audio and USB  connectors. 1 RJ‐45 Network barrel  Extron  connectors 1 Digital Document  Samsung Camera 1 8 outlet Power strip Tripp Lite Model Cable Cubby ‐ Model  #1200 (part no. 60‐1397‐ 02) AAP Super Plate 100  (part no. 70‐1076‐02)   Location  Instructor Table Installed in Cable  Cubby. AAP RJ‐45  (part no. 70‐ Installed in Cable  491‐11) Cubby. SDP‐960 Instructor Table PS2408 Instructor Table Function Access point for instructor to connect  laptop, document camera and other  devices to ceiling mounted projector. Provides connections to LCD projector  for digital document camera/laptop,  laptop audio, HDMI components and  easy USB connection to instructor PC. Note: All compiled and uncompiled Touch Screen programming will be provided to MCCC upon completion of  testing/acceptance of systems. Component 1 Media controller 1 Audio Amplifier 1 Volume control  modules 2 Speakers Manufacturer Extron Extron Extron MPA 152+ MLA VC 10 Plus Extron FF 220T (wired for 8  ohm) ECB2SP‐CR 1 Plenum  Wiremold box/projector ceiling  mount for audio  amplifiers 1 LCD Projector mount Peerless 1 Extension pipe Model MLC 226 IP ‐ L Extron 1 Recess mounted tab‐ Da‐lite tensioned projection  screens w/wall  mounted switch and  low voltage control Note: All cables from the instructor lectern to the projectors/audio system (video, audio, control, network, electric) must be able to be disconnected in a floor box located under the lectern location.  Recommended floor box size is 12" x 12" x 8".  RapidRun cables are to utilize standard RapidRun connections.   A custom bulkhead panel accomodating all connections will need to be installed the box. Qty Cable Type Manufacturer 1 Digital runner  Cables To Go w/flying leads (1  active, 1 passive) 2 Analog runner  Cables To Go w/flying leads (VGA  w/3.5mm audio) Bulk 16 gauge  Beldin speaker/control wire  Location Rapid Run ‐ Digital Rapid Run ‐ Analog 1 control cable Beldin Cat 5e 1 control cable Beldin Cat 5e 1 Cat 5e cable Beldin Cat 5e 1 Cat 5e cable Beldin 1 Audio cable 3.5mm M‐M 1 18‐3 control cable Beldin 1 RJ‐45 to DB‐9  Adapter Cables to Go 3 wire to 3.5mm M Function From MLM‐WB+ to  For HDMI signals (projector end of cable  Plenum box/LCD  requires Active Flying Lead) to LCD  projector projectors (2) From MLM‐WB+ to  For VGA  Plenum box/LCD  projector From audio amplifier in  (Cable Cubby) to Plenum box/LCD  plenum boxs to each  projector speaker/From MLA VC  10 + to MPA 152 + From Extron MLC 226 IP‐ Controls raising and lowering of  L Media Controller to  projection screen. low voltage control of  projection screen RS‐232 control of projector From Extron Media  Controller to LCD  Projector MLC 226 IP‐L  Remote monitoring/control connection to network From MLC 226 IP to MLA  Volume control VC 10+ From LCD projector to  Program audio for room MPA 152+ From MLC 226 IP ‐ L to  RS‐232‐C input switching control of  Document Camera document camera. Mounted to projector  Communication/control of projector by  RS‐232 port Extron MediaLink controller. Notes: The PC is to be mounted under the instructor table.    Cable Cubby #1 will provide electric for the PC monitor and a pass through plate for the monitor cable and USB connectors for keyboard, mouse and USB flash drives. Cable Cubby #2 will provide a VGA connection for the document camera/laptop (switched by document camera); an audio connection for the laptop, electric for the document camera/laptop or an instructor provided device and and HDMI connection. Electrical needs: Cable Cubby (2 outlets) Instructor PC (2 outlets ‐ PC and Monitor) Auxiliary outlets (power strip mounted to bottom or side of instructor table) Model Cable Cubby ‐ Model  #1200 (part no. 60‐1397‐ 02) AAP Super Plate 100  (part no. 70‐1076‐02)   Location  Instructor Table Installed in Cable  Cubby. AAP RJ‐45  (part no. 70‐ Installed in Cable  491‐11) Cubby. SDP‐960 Instructor Table PS2408 Instructor Table Function Access point for instructor to connect  laptop, document camera and other  devices to ceiling mounted projector. Provides connections to LCD projector  for digital document camera/laptop,  laptop audio, HDMI components and  easy USB connection to instructor PC. Qty Component 1 Media connector  plate  Manufacturer Extron  1 Connector plate with  Extron  HDMI, VGA, 3.5mm  audio and USB  connectors. 1 RJ‐45 Network barrel  Extron  connectors 1 Digital Document  Samsung Camera Display of documents/images and switch  for auxilary VGA devices (ie. Laptops,  etc.) Access to power for devices 1 8 outlet Power strip Tripp Lite Model Cable Cubby ‐ Model  #1200 (part no. 60‐1397‐ 02) AAP Super Plate 100  (part no. 70‐1076‐02)   Location  Instructor Table Installed in Cable  Cubby. AAP RJ‐45  (part no. 70‐ Installed in Cable  491‐11) Cubby. SDP‐960 Instructor Table PS2408 Instructor Table Function Access point for instructor to connect  laptop, document camera and other  devices to ceiling mounted projector. Provides connections to LCD projector  for digital document camera/laptop,  laptop audio, HDMI components and  easy USB connection to instructor PC. Display of documents/images and switch  for auxilary VGA devices (ie. Laptops,  etc.) Access to power for devices Media Control Components Media Control Components Note: All compiled and uncompiled Touch Screen programming will be provided to MCCC upon completion of  testing/acceptance of systems. Note: All compiled and uncompiled Touch Screen programming will be provided to MCCC upon completion of  testing/acceptance of systems. Qty Qty Component 1 Media controller Manufacturer Extron Model MLC 226 IP Location  Wall near instructor  table 1 Audio Amplifier 1 Volume control  modules 2 Speakers Extron Extron MPA 152+ MLA VC 10 Plus Projector plenum box Media wall box Extron FF 220T (wired for 8  ohm) ECB2SP‐CR Ceiling (fits in 2' x 2'  grid) In drop ceiling area Wiremold 1 Plenum  box/projector ceiling  mount for audio  amplifiers 1 LCD Projector mount Peerless PRG‐UNV Cables Manufacturer Extron  1 8 outlet Power strip Tripp Lite Location  Function Installed in UCM‐RAAP Provide control of projector inputs,  projection screens, volume levels.  Installed in wall near instructor. Projector plenum box For Program Audio and Voice Lift Audio Projector plenum box Separate volume control of audio  amplifiers for voice and program Ceiling (fits in 2' x 2'  6 for program audio, 6 for voice system grid) In drop ceiling area Above ceiling projector mount and  housing of electrical power for projector  and audio amplifier. Attaches projector to  All cabling to projectors is run through  ceiling mounting plate the above ceiling mounting  plate/plenum box and this mount.   PMP* Length to be determined so that the LCD  projector aligns with the top of the  projection screen.  All cabling to the  projector is to be routed through the  PMP. Boardroom Electrol  At designated location  Low voltage control to interface with  Wide Format 60" x 96"  in the front of the  Extron controls.  Wall mounted switch  matte screen with a  classroom. (standard voltage) also required in case  minimum 12" black  of system failure. drop* (Note: Black drop  may be more  based on  ceiling height at  location and the top of  the projection surface  being 8' above finished  floor) Component 1 Media connector  plate  1 Connector plate with  Extron  HDMI, VGA, 3.5mm  audio and USB  connectors. 1 RJ‐45 Network barrel  Extron  connectors 1 Digital Document  Samsung Camera Display of documents/images and switch  for auxilary VGA devices (ie. Laptops,  etc.) Access to power for devices Media Control Components Qty Qty Trenton Hall Annex ‐ Allied Health ‐ 2nd floor classroom 1 Extension pipe Extron 1 Recess mounted tab‐ Da‐lite tensioned projection  screens w/wall  mounted switch and  low voltage control Function Provide control of projector inputs,  projection screens, volume levels.  Installed in wall near instructor. For Program Audio and Voice Lift Audio Separate volume control of audio  amplifiers for voice and program 6 for program audio, 6 for voice system Above ceiling projector mount and  housing of electrical power for projector  and audio amplifier. Component 1 Media controller Manufacturer Extron Model MLC 226 IP Location  Wall near instructor  table 1 Audio Amplifier 1 Volume control  modules 2 Speakers Extron Extron MPA 152+ MLA VC 10 Plus Projector plenum box Media wall box Extron FF 220T (wired for 8  ohm) ECB2SP‐CR Ceiling (fits in 2' x 2'  grid) In drop ceiling area Wiremold 1 Plenum  box/projector ceiling  mount for audio  amplifiers 1 LCD Projector mount Peerless PRG‐UNV Attaches projector to  All cabling to projectors is run through  ceiling mounting plate the above ceiling mounting  plate/plenum box and this mount.   PMP* Length to be determined so that the LCD  projector aligns with the top of the  projection screen.  All cabling to the  projector is to be routed through the  PMP. Boardroom Electrol  At designated location  Low voltage control to interface with  Wide Format 60" x 96"  in the front of the  Extron controls.  Wall mounted switch  matte screen with a  classroom. (standard voltage) also required in case  minimum 12" black  of system failure. drop* (Note: Black drop  may be more  based on  ceiling height at  location and the top of  the projection surface  being 8' above finished  floor) 1 Extension pipe Extron 1 Recess mounted tab‐ Da‐lite tensioned projection  screens w/wall  mounted switch and  low voltage control Function Provide control of projector inputs,  projection screens, volume levels.  Installed in wall near instructor. For Program Audio and Voice Lift Audio Separate volume control of audio  amplifiers for voice and program 6 for program audio, 6 for voice system Above ceiling projector mount and  housing of electrical power for projector  and audio amplifier. PRG‐UNV Attaches projector to  All cabling to projectors is run through  ceiling mounting plate the above ceiling mounting  plate/plenum box and this mount.   PMP* Length to be determined so that the LCD  projector aligns with the top of the  projection screen.  All cabling to the  projector is to be routed through the  PMP. Boardroom Electrol  At designated location  Low voltage control to interface with  Wide Format 60" x 96"  in the front of the  Extron controls.  Wall mounted switch  matte screen with a  (standard voltage) also required in case  classroom. minimum 12" black  of system failure. drop* (Note: Black drop  may be more  based on  ceiling height at  location and the top of  the projection surface  being 8' above finished  floor) Cables Cables Note: All cables from the instructor lectern to the projectors/audio system (video, audio, control, network, electric) must be able to be disconnected in a floor box located under the lectern location.  Recommended floor box size is 12" x 12" x 8".  RapidRun cables are to utilize standard RapidRun connections.   A custom bulkhead panel accomodating all connections will need to be installed the box. Note: All cables from the instructor lectern to the projectors/audio system (video, audio, control, network, electric) must be able to be disconnected in a floor box located under the lectern location.  Recommended floor box size is 12" x 12" x 8".  RapidRun cables are to utilize standard RapidRun connections.   A custom bulkhead panel accomodating all connections will need to be installed the box. Qty Cable Type Manufacturer Location Cables To Go Rapid Run ‐ Digital Cables To Go 2 Analog runner  w/flying leads (VGA  w/3.5mm audio) Rapid Run ‐ Analog 1 Digital runner  w/flying leads (1  active, 1 passive) Beldin Bulk 16 gauge  speaker/control wire  1 control cable Beldin Cat 5e 1 control cable Beldin Cat 5e 1 Cat 5e cable Beldin Cat 5e 1 Cat 5e cable Beldin 1 Audio cable 3.5mm M‐M 1 18‐3 control cable Beldin 1 RJ‐45 to DB‐9  Adapter Cables to Go 3 wire to 3.5mm M Function From Instructor Table  For HDMI signals (projector end of cable  (Cable Cubby) to  requires Active Flying Lead) to LCD  Plenum box/LCD  projectors (2) projector From Instructor Table  For VGA  (Cable Cubby) to  Plenum box/LCD  projector From audio amplifier in  (Cable Cubby) to Plenum box/LCD  plenum boxs to each  projector speaker/From MLA VC  10 + to MPA 152 + From Extron MLC 226 IP  Controls raising and lowering of  Media Controller to  projection screen. low voltage control of  projection screen From Extron Media  RS‐232 control of projector Controller to LCD  Projector MLC 226 IP connection  Remote monitoring/control to network From MLC 226 IP to MLA  Volume control VC 10+ From LCD projector to  Program audio for room MPA 152+ RS‐232‐C input switching control of  From MLC 226 IP to  Document Camera document camera. Mounted to projector  Communication/control of projector by  RS‐232 port Extron MediaLink controller. Notes: The PC is to be mounted under the instructor table.    Cable Cubby #1 will provide electric for the PC monitor and a pass through plate for the monitor cable and USB connectors for keyboard, mouse and USB flash drives. Cable Cubby #2 will provide a VGA connection for the document camera/laptop (switched by document camera); an audio connection for the laptop, electric for the document camera/laptop or an instructor provided device and and HDMI connection. Electrical needs: Cable Cubby (2 outlets) Instructor PC (2 outlets ‐ PC and Monitor) Auxiliary outlets (power strip mounted to bottom or side of instructor table) Qty Cable Type Manufacturer Location Cables To Go Rapid Run ‐ Digital Cables To Go 2 Analog runner  w/flying leads (VGA  w/3.5mm audio) Rapid Run ‐ Analog 1 Digital runner  w/flying leads (1  active, 1 passive) Bulk 16 gauge  Beldin speaker/control wire  1 control cable Beldin Cat 5e 1 control cable Beldin Cat 5e 1 Cat 5e cable Beldin Cat 5e 1 Cat 5e cable Beldin 1 Audio cable 3.5mm M‐M 1 18‐3 control cable Beldin 1 RJ‐45 to DB‐9  Adapter Cables to Go 3 wire to 3.5mm M Function From Instructor Table  For HDMI signals (projector end of cable  (Cable Cubby) to  requires Active Flying Lead) to LCD  Plenum box/LCD  projectors (2) projector From Instructor Table  For VGA  (Cable Cubby) to  Plenum box/LCD  projector From audio amplifier in  (Cable Cubby) to Plenum box/LCD  plenum boxs to each  projector speaker/From MLA VC  10 + to MPA 152 + From Extron MLC 226 IP  Controls raising and lowering of  Media Controller to  projection screen. low voltage control of  projection screen From Extron Media  RS‐232 control of projector Controller to LCD  Projector MLC 226 IP connection  Remote monitoring/control to network From MLC 226 IP to MLA  Volume control VC 10+ From LCD projector to  Program audio for room MPA 152+ RS‐232‐C input switching control of  From MLC 226 IP to  Document Camera document camera. Mounted to projector  Communication/control of projector by  RS‐232 port Extron MediaLink controller. Notes: The PC is to be mounted under the instructor table.    Cable Cubby #1 will provide electric for the PC monitor and a pass through plate for the monitor cable and USB connectors for keyboard, mouse and USB flash drives. Cable Cubby #2 will provide a VGA connection for the document camera/laptop (switched by document camera); an audio connection for the laptop, electric for the document camera/laptop or an instructor provided device and and HDMI connection. Electrical needs: Cable Cubby (2 outlets) Instructor PC (2 outlets ‐ PC and Monitor) Auxiliary outlets (power strip mounted to bottom or side of instructor table)